Abstract
Background
Central venous catheters (CVCs) play a vital role in the management of acute and chronic illness. Dressings and securement devices must ensure CVCs do not dislodge or fall out, provide a barrier protection from microbial colonisation and infection, and be comfortable for the patient. There is a large range of dressing and securement products available for clinicians to use.
Objectives
To compare the available dressing and securement devices for CVCs, in terms of catheter‐related bloodstream infection (BSI), catheter colonisation, entry‐ and exit‐site infection, skin colonisation, skin irritation, failed catheter securement, dressing condition and mortality.
Search methods
In June 2015 we searched: The Cochrane Wounds Group Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL); The Database of Abstracts of Reviews of Effects (DARE); NHS Economic Evaluation Database (NHSEED); Ovid MEDLINE; Ovid MEDLINE (In‐Process & Other Non‐Indexed Citations); Ovid EMBASE; EBSCO CINAHL; six clinical trial registries and reference lists of identified trials. There were no restrictions based on language or date of publication or study setting.
Selection criteria
We included randomised controlled trials that evaluated the effects of dressing and securement devices for CVCs. All types of CVCs were included, i.e. short‐ and long‐term CVCs, tunnelled and non‐tunnelled, port‐a‐caths, haemodialysis catheters, and peripherally‐inserted central catheters (PICCs).
Data collection and analysis
We used standard Cochrane Collaboration methods including independent review of titles and abstracts for relevance, data extraction, and risk of bias assessment of the included studies by two review authors. Results are expressed using risk ratio (RR) for categorical data with 95% confidence intervals (CIs). For outcomes best presented as a rate‐per‐time‐period, rate ratios and standard errors have been used. We performed multiple treatment meta‐analyses to rank the effectiveness of each intervention for each outcome.
Main results
We included 22 studies involving 7436 participants comparing nine different types of securement device or dressing. All included studies were at unclear or high risk of performance bias due to the different appearances of the dressings and securement devices. The extent of blinding of outcome assessment was unclear in most studies. The quality of evidence varied between different comparisons and outcomes. We mainly downgraded the quality of evidence for imprecision, indirectness, risk of bias and inconsistency.
It is unclear whether there is a difference in the rate of catheter‐related BSI between securement with gauze and tape and standard polyurethane (SPU) (RR 0.64, 95% CI 0.26 to 1.63, low quality evidence), or between chlorhexidine gluconate‐impregnated (CGI) dressings and SPU (RR 0.65, 95% CI 0.40 to 1.05, moderate quality evidence). There is high quality evidence that medication‐impregnated dressings reduce the incidence of catheter‐related BSI relative to all other dressing types (RR 0.60, 95% CI 0.39 to 0.93).
There is moderate quality evidence that CGI dressings reduce the frequency of catheter‐related BSI per 1000 patient days compared with SPU dressings (RR 0.51, 95% CI 0.33 to 0.78).
There is moderate quality evidence that catheter tip colonisation is reduced with CGI dressings compared with SPU dressings (RR 0.58, 95% CI 0.47 to 0.73), but the relative effects of gauze and tape and SPU are unclear (RR 0.95, 95% CI 0.51 to 1.77, very low quality evidence). It is unclear if there is a difference in rates of skin irritation or damage when CGI dressings are compared with SPU dressings (moderate quality evidence) (RR 11.17, 95% CI 0.84 to 149.48).
A multiple treatment meta‐analysis found sutureless securement devices as likely to be the most effective at reducing the incidence of catheter‐related BSI (low quality evidence), with CGI dressings ranked second (low quality evidence).
Authors' conclusions
Medication‐impregnated dressing products reduce the incidence of catheter‐related BSI relative to all other dressing types. There is some evidence that CGI dressings, relative to SPU dressings, reduce catheter‐related BSI for the outcomes of frequency of infection per 1000 patient days, risk of catheter tip colonisation and possibly risk of catheter‐related BSI. A multiple treatment meta‐analysis found that sutureless securement devices are likely to be the most effective at reducing catheter‐related BSI though this is low quality evidence. Most studies were conducted in intensive care unit (ICU) settings. More, high quality research is needed regarding the relative effects of dressing and securement products for CVCs. Future research may adjust the estimates of effect for the products included in this review and is needed to assess the effectiveness of new products.
Plain language summary
Dressings and securement for central venous catheters (CVCs)
Background
A central venous catheter (CVC) is a tube that is inserted into a blood vessel to enable the delivery of liquid nutrition, blood, medicine or fluids (or a combination of these) to a person who is ill. If a CVC is in place the patient does not need to suffer repeated needle insertions when treatments are due, as tubes can be attached to the CVC, the required fluid pumped in, and then the tubes detached when appropriate.
CVCs need to be secured adequately, usually with a dressing of some kind, in order to prevent them from becoming dislodged and to avoid infection (for example, catheter‐related bloodstream infections (BSI)), and need to be comfortable for the patient. Many different types of products are available to secure CVCs, but it is not known which works best.
Review question
The objective of this research was to compare the available dressings and securement devices for CVCs to identify which works best.
What we found
The researchers searched medical databases up to September 2014, and identified 22 studies with a total of 7436 participants that were relevant to the research question. The studies investigated the following comparisons:
‐ nine studies compared sterile gauze with standard polyurethane dressings; ‐ six studies compared standard polyurethane dressings with chlorhexidine gluconate‐impregnated dressings (chlorhexidine gluconate is an antibacterial disinfectant); ‐ one study compared standard polyurethane dressings with silver‐impregnated dressings (silver compounds may have antibacterial properties); ‐ one study compared standard polyurethane dressings with hydrocolloid dressings; ‐ one study compared 'modern' gas permeable standard polyurethane dressings with 'old' (original) standard polyurethane dressings; ‐ one study compared highly adhesive transparent standard polyurethane dressings with chlorhexidine gluconate dressings; ‐ one study compared standard polyurethane dressings with sutureless (stitchless) securement devices; ‐ one study compared sterile gauze with no dressing; and ‐ one study compared chlorhexidine gluconate dressings with no dressings.
The included studies sometimes did not clearly report the methods they had used to minimise accidental or statistical error, but overall the methods were adequate.
Analysis of the study results showed that there is high quality evidence that securing a CVC with a dressing impregnated with a medication (chlorhexidine gluconate‐impregnated or silver) reduces catheter‐related blood stream infection compared with a dressing without medication. The results indicated moderate quality evidence for a reduction in the frequency of catheter‐related BSI per 1000 patient days (this is a unit used in research that represents patient use; in this case 1000 patient days is equal to 1000 patients using CVCs for one day, or 500 patients using CVCs for two days, or 250 patients using CVCs for four days, etc.) when a chlorhexidine gluconate‐impregnated dressing was used rather than a standard polyurethane dressing. When the risk of infection with chlorhexidine gluconate‐impregnated dressings was compared with the risk with standard polyurethane dressings in another way (by calculating the ratio of the risk of infection with one versus the other without taking account to patient days of use) this difference was less clear. A less direct measure of infection, that is the extent of bacterial colonisation of the tip of the catheter after removal, showed more bacteria with the standard polyurethane dressing (moderate quality evidence).
The studies that contributed to this research were mainly carried out in intensive care unit settings, where a large number of CVCs are used for short durations. Other types of dressings and securement products for CVCs that were investigated by the studies analysed here did not show any observable effects on catheter‐related BSI, catheter tip colonisation or any of the other outcomes assessed, such as skin irritation, failed catheter securement, condition of the dressing and patient death.
More, high quality research is needed to investigate the relative effects of the wide range of dressing and securement products that are available for CVCs.
This plain language summary is up‐to‐date as of 5th June, 2015.
Summary of findings
Background
Description of the condition
Central venous catheters (CVCs) play an important role in the management of patients, providing reliable vascular access and a site for venous pressure monitoring. They are inserted when a patient requires venous access over an extended period of time, and allow the intravenous administration of complex drug treatments, blood products and nutritional support without the trauma associated with repeated needle insertions (Webster 2011). Although mostly used in intensive‐care units and oncology settings, CVCs are increasingly being used in other wards and outpatient settings.
There are multiple types of CVCs in use throughout clinical practice. A CVC can be designated by: its intended life span (e.g. temporary or short‐term versus permanent or long‐term); the site of insertion (e.g. subclavian vein, femoral vein, internal jugular vein or peripherally inserted central catheter (PICC)); the pathway from skin to vessel (e.g. tunnelled versus non‐tunnelled); the physical length (e.g. long versus short) or some other special characteristic(s) (e.g. impregnation with heparin or number of lumens (lines); O'Grady 2011). More information regarding the variety of catheters used in clinical practice is included in Appendix 1.
Owing to the invasive procedure necessary for inserting a CVC and the resulting break in the skin (integument), complications such as exit‐site infections and bloodstream infections can develop (Han 2010). A serious complication of CVCs is catheter‐related blood stream infections (BSI), also known as 'catheter sepsis'. Catheter‐related BSI rates are influenced by patient‐related factors, such as severity and type of illness (e.g. full‐thickness burns versus post‐cardiac surgery), by catheter‐related factors (such as the condition under which the catheter was placed and catheter type), and by institutional factors (e.g. bed numbers, hospital affiliation with an academic institution; O'Grady 2011). Many studies have estimated the incidence of catheter‐related BSI, generally reporting a range between 1 and 3.1 per 1000 patient days, primarily within the adult intensive care unit (ICU) setting (Pronovost 2006; Schwebel 2012), but rates have been shown to decrease to zero after the introduction of interventions involving handwashing and skin antisepsis (Han 2010). The attributable cost of catheter‐related BSI has been estimated within the adult ICU population and varies between USD 3124 and USD 60,536 per event when considering hospital staffing and consumables (Raad 2007; Schwebel 2012), and is associated with an attributable mortality of 0% to 11.5% (Timsit 2011).
CVCs are foreign objects, and, as such, require their external component to be both protected adequately from microbial contamination from the surrounding environment and secured to the skin. Dressings and securements must ensure CVCs do not dislodge or fall out (or both), or move within or out of the great veins. This can occur via movement or pressure on the external component of the device, through forced removal, or ‘drag’ from infusion tubing or ‘catching’ on environmental structures (Naimer 2004). Movement of the CVC to a location outside the target placement can result in line failure or cardiovascular instability. In critical situations line failure (e.g. the interruption of inotropic support during cardiogenic shock) can have catastrophic consequences for the patient's morbidity and mortality.
Description of the intervention
There is a plethora of CVC dressings and securement devices from which clinicians may select. The earliest securement approach was simple tape or gauze‐tape, with plastic film dressings becoming prominent in the 1980s. First‐generation occlusive standard polyurethane (SPU) dressings were later developed to become semi‐permeable to oxygen, carbon dioxide and water vapour (e.g. OpSite IV 3000®, Smith and Nephew; Tegaderm Plus®, 3M), as occlusive dressings trap moisture on the skin and so provide an ideal environment for quick growth of local microflora (Frasca 2010). Each dressing is transparent, permitting continuous visual inspection of the catheter site. A recent approach to CVC securement is the bordered polyurethane (BPU) dressing that retains the clear central polyurethane component of SPU dressings with an added external adhesive border of foam or cloth fabric to maximise catheter security (e.g. Tegaderm Advanced®, 3M).
The majority of catheter‐related BSI are caused by micro‐organisms found in the patient's own commensal skin flora, such as Staphylococcus epidermidis and Staphylococcus aureus (Timsit 2011); consequently, in recent years we have seen the arrival of medication‐impregnated dressings. The most common of these are the chlorhexidine gluconate‐impregnated (CGI) dressings. These CGI dressings release chlorhexidine gluconate on the underlying cutaneous surface when placed over the catheter insertion site (Arvaniti 2012). Chlorhexidine gluconate is a cationic biguanide that provides rapid antisepsis because of its broad spectrum of germicidal activity against most catheter‐related BSI‐causing pathogens (Garland 2001). Chlorhexidine gluconate impregnates the whole dressing, or is applied using an impregnated sponge (e.g. Biopatch®) and covered by a transparent polyurethane dressing. Other medication‐impregnated dressings include silver‐impregnated and iodine‐impregnated dressings (Wille 1993). The iodine‐impregnated dressings release free iodine when exposed to wound exudate, while the silver‐impregnated dressings expose the entrance site to silver ions; both iodine and silver have antimicrobial properties. Some researchers recommend the use of hydrocolloid dressings for the dressing of CVCs. This type of dressing is traditionally used on open wound sites to promote moist healing as the hydrocolloid matrix absorbs excess moisture away from the skin surface, and so reduces the likelihood of microbial growth (Nikoletti 1999).
Securement of the CVC is also facilitated by mechanisms other than dressings. Traditionally, CVCs were routinely sutured in place, prior to a dressing being applied (O'Grady 2011). In addition to this option, clinicians frequently reinforced the device security using non‐commercial options including sterile strips or non‐sterile tape. Recently, sutureless securement devices (SSD) have become available commercially. These are used in addition to transparent dressings, and use a large adhesive footplate and an underlying pad with an device‐locking clasp (e.g. StatLock®, Bard). These theoretically reduce movement, kinking and flow impedance, and maximise catheter stabilisation (Yamamoto 2002).
Each of these CVC dressing and securement types has different therapeutic goals and is readily available for clinicians and patients to purchase from numerous suppliers, depending upon the treatment setting (e.g. outpatients). The diversity of dressings and securement devices available to clinicians (including variation within each of the types discussed above) makes evidence‐based decision‐making difficult in this area. With the availability of increasingly sophisticated and expensive CVC dressings and securements, practitioners need to know how effective these dressings are compared with more traditional dressings.
How the intervention might work
The ideal CVC dressing and securement device should:
provide a barrier that protects from microbial colonisation and infection, preventing catheter related BSI;
provide adequate securement to prevent accidental removal, partial dislodgement and micro‐motion, thus preventing CVC failure;
be comfortable and non‐irritating for the patient;
be easy to use; and
be cost‐effective.
Several studies have reported the effects of interventions to reduce catheter‐related BSI rates, including maximal sterile precautions during insertion, skin antisepsis, securement devices and antimicrobial catheter coatings (Han 2010; Levy 2005; Timsit 2011). The role of the CVC dressing in preventing catheter‐related BSI is to provide a protective barrier that prevents migration of skin organisms at the insertion site into the cutaneous catheter tract ‐ and subsequent colonisation of the catheter tip ‐ and preventing direct contamination of the catheter by contact with hands and other materials (O'Grady 2011).
Why it is important to do this review
Decreasing the incidence of catheter‐related BSI and preventing CVC failure are important objectives with a significant impact on patient morbidity and mortality, yet there is no consensus on the optimal dressing or securement type to use with CVCs, despite more than two decades of research and debate. An earlier Cochrane review, 'Gauze and tape and polyurethane dressings for CVC', focused on only two product types (Webster 2011), and, therefore, does not address adequately the variety of products now available in the clinical environment. A large variety of dressings and types of securement is currently available for use with CVCs, including medication‐impregnated dressings and sutureless securement devices.
Objectives
To compare the available dressings and securement devices for CVCs, in terms of catheter‐related bloodstream infection (BSI), catheter colonisation, entry‐ and exit‐site infection, skin colonisation, skin irritation, failed catheter securement, dressing condition and mortality.
Methods
Criteria for considering studies for this review
Types of studies
We included all randomised controlled trials (RCTs) that evaluated the effects of CVC dressings and securement devices for their impact on catheter‐related BSI, catheter colonisation, entry‐ and exit‐site infection, skin colonisation, skin irritation, catheter security, dressing condition or mortality, irrespective of publication status or language. We would have included controlled clinical trials (CCTs) only in the absence of RCTs. CCTs are studies in which the trial involves testing an intervention and a control, with concurrent enrolment and follow‐up of test and control‐treated groups, but the method of allocation is not considered to be strictly random (Lefebvre 2011). We also excluded cross‐over and cluster‐randomised trials in order to minimise potential bias in accordance with Reeves 2011.
Types of participants
Any person of any age requiring a CVC in any healthcare or community setting. All CVCs were included, i.e. short‐ and long‐term CVCs, tunnelled and non‐tunnelled, port‐a‐caths, haemodialysis catheters, and peripherally‐inserted central catheters (PICCs). For studies that included other types of vascular catheter, only data pertaining to CVCs were included.
Types of interventions
We included trials that compared any CVC dressings or securement device including, but not limited to, the following.
Dressings
Gauze and tape.
Standard polyurethane (SPU) dressings: semi‐permeable and highly permeable.
Highly adhesive polyurethane dressings.
Bordered polyurethane (BPU) dressings.
Chlorhexidine gluconate‐impregnated (CGI) dressings.
Other medication‐impregnated dressings.
Hydrocolloid dressings.
No dressing.
Securement device
Sutureless securement devices (SSD).
Sutures.
No securement.
Types of outcome measures
Primary outcomes
Incidence of catheter‐related blood stream infection (BSI): as defined by one of the following three criteria.
Primary bacteraemia/fungaemia with at least one positive blood culture from a peripheral vein with no other identifiable source for the BSI other than the CVC, plus, one of: a positive semiquantitative (> 15 colony‐forming units (cfu)) or quantitative (> 10³ cfu) device culture, with the same organism (species and antibiogram) isolated from the device and blood (Maki 2006; O'Grady 2002).
Two blood cultures (one from an CVC hub and one from a peripheral vein), that both meet the CVC related‐BSI criteria for quantitative blood cultures (three‐fold greater colony count of growth for the same organism as from the peripheral blood), or differential time to positivity (DTP; growth of the same microbe from hub drawn blood at least two hours before growth from the peripheral blood; Mermel 2009).
Two quantitative blood cultures of samples obtained through two catheter lumens in which the colony count for the blood sample drawn through one lumen is at least three‐fold greater than the colony count for the blood sample from the second lumen (Mermel 2009).
Secondary outcomes
Frequency of catheter‐related BSI per 1000 patient days: catheter‐related BSI as previously defined.
Incidence of catheter tip colonisation: positive semi‐quantitative (> 15 cfu/catheter segment) or quantitative (> 10³ cfu/catheter segment) culture from a proximal or distal catheter segment (O'Grady 2002).
Incidence of entry‐ and exit‐site infection: as described by the trial investigator.
Incidence of skin/site colonisation: positive semi‐quantitative (> 15 cfu) or quantitative (> 10³ cfu) culture from the skin around the catheter site (O'Grady 2002).
Incidence of skin irritation or damage: as described by the study investigator using a formal assessment tool (e.g. erythema and dryness scales; Kampf 2005).
Incidence of failed catheter securement: frequency of accidental or forced removal or dislocation resulting in CVC failure.
Dressing condition/durability: incidence or mean score using a formal assessment tool (e.g. Pedrolo 2011).
Mortality from any cause.
Studies must have reported at least one pre‐specified outcome, in accordance with these definitions, in order to be included in this systematic review.
Search methods for identification of studies
Electronic searches
We searched the following electronic databases to identify reports of relevant randomised clinical trials:
The Cochrane Wounds Group Specialised Register (5 June 2015);
The Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library 2015, Issue 6);
The Database of Abstracts of Reviews of Effects (DARE; The Cochrane Library 2015, Issue 6);
NHS Economic Evaluation Database (The Cochrane Library 2015, Issue 6);
Ovid MEDLINE (1946 to June 04, 2015);
Ovid MEDLINE (In‐Process & Other Non‐Indexed Citations, June 04, 2015);
Ovid EMBASE (1974 to June 04, 2015);
EBSCO CINAHL (1982 to June 04, 2015).
We used the following search strategy in CENTRAL:
#1MeSH descriptor: [Catheterization, Central Venous] explode all trees (779 citations) #2(venous near/3 (catheter* or line*)):ti,ab,kw (1526 citations) #3(central near/3 (catheter* or line*)):ti,ab,kw (1408 citations) #4(hickman next catheter*):ti,ab,kw (33 citations) #5(broviac next catheter*):ti,ab,kw (9 citations #6(cook next catheter*):ti,ab,kw (4 citations) #7MeSH descriptor: [Catheters, Indwelling] explode all trees (959 citations) #8("implantable vascular access device" or IAVD or PortACath):ti,ab,kw (3 citations) #9("peripherally inserted central catheter" or PICC):ti,ab,kw (68 citations) #10(h*emodialysis next catheter*):ti,ab,kw (111 citations) #11#1 or #2 or #3 or #4 or #5 or #6 or #7 or #8 or #9 or #10 (2414 citations) #12MeSH descriptor: [Occlusive Dressings] explode all trees (451 citations) #13MeSH descriptor: [Bandages, Hydrocolloid] explode all trees (162 citations) #14MeSH descriptor: [Silver] explode all trees (177 citations) #15MeSH descriptor: [Silver Sulfadiazine] explode all trees (145 citations) #16MeSH descriptor: [Polyurethanes] explode all trees (373 citations) #17MeSH descriptor: [Iodine] explode all trees (324 citations) #18MeSH descriptor: [Chlorhexidine] explode all trees (1375 citations) #19((occlusive* or hydrocolloid* or silver* or polyurethane* or permeable or nonpermeable or non‐permeable or transparent or chlorhexidine or iodine* or gauze or tape) near/3 (dressing* or sponge*)):ti,ab,kw (1184 citations) #20#12 or #13 or #14 or #15 or #16 or #17 or #18 or #19 (3391 citations) #21#11 and #20 (203 citations)
We adapted this strategy to search Ovid MEDLINE, Ovid EMBASE and EBSCO CINAHL, details of these searches can be found in Appendix 2. We combined the Ovid MEDLINE search with the Cochrane Highly Sensitive Search Strategy for identifying randomised trials in MEDLINE: sensitivity‐ and precision‐maximising version (2008 revision; Lefebvre 2011). We combined the EMBASE search with the Ovid EMBASE filter developed by the UK Cochrane Centre (Lefebvre 2011). We combined the CINAHL searches with the trial filters developed by the Scottish Intercollegiate Guidelines Network (SIGN 2012). There were no restrictions on the basis of date, study setting, language or publication status.
We also searched the following clinical trial registers:
ClinicalTrials.gov (http://www.clinicaltrials.gov/);
Current Controlled Trials (http://www.controlled‐trials.com/mrct);
Hong Kong clinical trials register (http://www.hkclinicaltrials.com);
Indian clinical trials registry (http://ctri.nic.in/Clinicaltrials/login.php);
UK Clinical Trials Gateway (http://www.controlled‐trials.com/ukctr/);
the World Health Organization (WHO) International Clinical Trials Registry Platform (http://apps.who.int/trialsearch/Default.aspx); and
EU Clinical Trials Register (https://www.clinicaltrialsregister.eu/ctr‐search/search)
Searching other resources
We handsearched bibliographies of all retrieved and relevant publications identified by these strategies for further relevant studies. We contacted experts in the field to ask for information relevant to this review. We also contacted dressing and securement device manufacturers for unpublished data in order to counteract publication bias.
Data collection and analysis
Selection of studies
Independently, two review authors (AU and MM) assessed titles and abstracts of retrieved studies for relevance. After this initial assessment, we retrieved full versions of all potentially eligible studies. Independently, the same two review authors checked the full papers for eligibility. We resolved discrepancies between review authors through discussion and, where required, consulted a third independent review author (CR). For transparency we have published a summary of the selection of studies, including excluded studies and reasons for exclusion, using the PRISMA flowchart (Liberati 2009).
Data extraction and management
We extracted details from eligible studies and summarised them using a data extraction sheet. Due to the large number of studies included in this review, teams of two review authors reviewed specific interventions including: CGI dressing studies, gauze studies, SSD studies, paediatric and neonatal studies, and the remaining studies. These teams extracted data independently, which were cross‐checked for accuracy and agreed upon. We resolved any discrepancies though discussion and arbitration by a third review author, when necessary. For studies that were published in duplicate, we extracted maximal data from all relevant publications, but we did not duplicate data in analyses. When there were any data missing from the papers, we attempted to contact the trial authors to retrieve them.
We used a data extraction sheet to extract summary data from each trial. The data extraction sheet contained baseline characteristics of the study participants: their number; age; gender; disease; treatment; type of CVC; dressing or securement, or both; number of dressing changes during the dwell time of the CVC; and healthcare setting in which the intervention occurred. We listed each trial's criteria for participant inclusion and exclusion, a description of the intervention(s), the number of people randomised to each intervention, and primary and secondary outcome measures.
Assessment of risk of bias in included studies
Each eligible study was independently assessed for methodological quality and bias using the Cochrane Collaboration 'Risk of bias' assessment tool. This tool addresses six specific domains, namely, sequence generation, allocation and concealment, blinding of participants/care providers, blinding of outcome assessors, incomplete outcome data, selective outcome reporting, as well as other issues that potentially may bias the study (Higgins 2011a). In accordance with Higgins 2011a, assessment for 'other' bias concerned baseline balance between treatment groups, early cessation of the trials and commercial sponsorship. We have completed a 'Risk of bias' table for each eligible study and outcome using the categories of 'low', 'high' or 'unclear' risk of bias. The criteria for judging risk of bias assessments (i.e. categories of low, high or unclear) were made in accordance with recommendations in Higgins 2011a. Assessment of risk of bias is discussed within the text and the judgements are presented as a 'Risk of bias' summary graph, which summarises judgements by domain, and a 'Risk of bias' summary figure, which cross‐tabulates judgements by study. Together these tools have been used to assess overall risk of bias, in combination with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach (Schunemann 2011). The GRADE approach assesses the quality of evidence per comparison and outcome throughout five factors: risk of bias, indirectness of the population, interventions and outcomes, inconsistency amongst studies, imprecision (including information size and confidence intervals) and publication bias.
We undertook data extraction for risk of bias from the included studies using the same approach explained above in Data extraction and management. We extracted and summarised data using a data extraction sheet. Teams of two review authors reviewed specific interventions, extracted data independently and cross‐checked the data for accuracy and agreement. We resolved any discrepancies through discussion and arbitration by a third review author, when necessary. We contacted trial authors if data pertaining to risk of bias was missing, including protocol‐based assessments of selective outcome reporting. The review authors searched trial registries, as previously described, to identify research protocols to enable assessment for selective outcome reporting.
Measures of treatment effect
Our primary analysis involves pair‐wise comparisons of treatment effect between dressing and securement types, using all the described outcomes. For dichotomous outcomes, we have calculated the risk ratio (RR) plus 95% confidence intervals (CI). For the outcome best presented as a rate‐per‐time‐period (i.e. catheter‐related BSI per 1000 patient days), we have used rate ratios (RaR) and standard errors (SE) to inform inverse‐variance analysis. This analysis required the provision of patient days per intervention group. As CVCs are inserted for variable durations, the rate of catheter‐related BSI per 1000 patient days was used to describe the variable frequency of catheter‐related BSI across the catheter duration between the CVC securement and dressing options.We undertook meta‐analysis when more than one study used the same intervention and reported the same outcome.
In addition to the main pair‐wise analysis described above, in order to inform clinical decision‐making we planned to undertake pair‐wise comparisons using the 'clustering' of interventions on the basis of patient treatment goals and outcomes. These clustering comparisons were done because of the heterogeneity of populations that use CVCs, and the way their goals for treatment differ. In order to minimise bias, these clustering comparisons were identified prior to undertaking the analyses. We planned to compare the following.
Catheter‐related BSI
Medication‐impregnated dressings (CGI, povidone‐iodine and silver‐impregnated etc.) versus non‐impregnated dressings (SPU, BPU, gauze and tape, hydrocolloid).
CGI‐impregnated dressings versus all other medication‐impregnated dressings (povidone‐iodine, silver etc.).
Silver‐impregnated dressings versus all other medication‐impregnated dressings (povidone‐iodine, CGI etc.).
Povidine‐iodine impregnated dressings versus all other medication‐impregnated dressings.
Gauze and tape versus SPU and BPU.
Incidence of skin irritation or damage
Hydrocolloid dressing versus all others.
Gauze and tape versus SPU and BPU.
CGI‐impregnated dressings versus SPU and BPU.
Failed catheter securement
BPU versus all non‐bordered dressings (SPU, hydrocolloid).
SSD versus all other dressing types.
No dressing versus all other dressing types.
Unit of analysis issues
The majority of the included RCTs randomised participants and not their CVCs. Two studies recruited participants multiple times for multiple CVCs: Carrer 2005 recruited 82 participants with 107 CVCs; Chambers 2005 recruited 95 participants with 114 CVCs. These studies falsely assumed independence of the CVCs, which provides a potential risk of bias. For the current review, attempts were made to contact the study authors in order to obtain the results for one CVC per participant, but these data were not available. For these studies, data involving CVCs as the unit of analysis were included. Future updates of this review will incorporate studies that used CVCs as the unit of analysis, rather than participants, in a sensitivity analysis to examine for potential risk of bias.
In accordance with Higgins 2011b, for included studies that involved the comparison of multiple interventions using a single control, we split the 'shared' control group to avoid additional unit of analysis issues. We did this to distribute the appropriate study weight and maintain independent comparisons fairly.
Dealing with missing data
When there was evidence of missing data, we attempted to contact the study authors to request the missing information. When after several attempts to contact the trial author the missing data were not provided, we analysed the available data only. We emailed the authors of ten included studies to ask for further information and clarification of key aspects of their study methods and results. Study authors from seven of the ten trials responded (de Barros 2009; Levy 2005; Nikoletti 1999; Olson 2004; Shivnan 1991; Timsit 2009; Timsit 2012), with four authors able to provide all information required (de Barros 2009; Levy 2005; Timsit 2009; Timsit 2012). We have also addressed the potential impact of the missing data on the findings of the review in the Discussion.
Loss to follow‐up and attrition data were adequate and well described by ten studies (Arvaniti 2012; Brandt 1996; Chambers 2005; Garland 2001; Giles 2002; Pedrolo 2011; Ruschulte 2009; Shivnan 1991; Timsit 2009; Timsit 2012). Five studies had high levels of attrition and loss to follow‐up (Carrer 2005; Conly 1989; le Corre 2003; Levy 2005; Nikoletti 1999). The remaining seven studies provided inadequate information regarding loss to follow‐up and attrition for us to assess for bias (de Barros 2009; Hagerstrom 1994; Hill 2010; Olson 2004; Roberts 1998; Wille 1993; Yamamoto 2002).
Assessment of heterogeneity
A random‐effects model was used for data synthesis because of predicted clinical heterogeneity. We considered clinical, methodological and statistical heterogeneity and undertook an assessment of comparability of the studies prior to meta‐analysis. We investigated the degree of statistical heterogeneity, that is, variation between the true intervention effects underlying the different studies, by a combination of methods. This involved visual inspection of the meta‐analytic model and interpretation of the Chi² and I² statistics that examine the total variance across studies due to heterogeneity rather than chance (Higgins 2003).
Assessment of reporting biases
We reported each outcome separately. We used funnel plots to assess reporting biases for the main analysis (Egger 1997; Analysis 1.1). Any asymmetry of the funnel plot may indicate possible publication bias.
1.1. Analysis.

Comparison 1 Primary analysis, Outcome 1 Catheter‐related blood stream infection.
Data synthesis
Initially we conducted a structured narrative summary of the studies included in the review to inform the development of meta‐analysis. We entered quantitative data into Review Manager (RevMan) 5.3 and analysed them using the RevMan analysis software (RevMan 2014). We pooled data for meta‐analysis using RevMan 5.3, and used a random‐effects model because of the clinical heterogeneity.
Multiple treatments meta‐analysis (MTM)
Due to the number of treatment options available for CVC securement and dressing, a 'multiple‐treatments meta‐analysis’ has been undertaken in order to assist clinicians in making meaningful‐decisions (Higgins 2011b; Salanti 2008). These analyses provide a 'ranking' of each intervention for example by the probability of each intervention being the best in terms of a particular outcome.
MTM data synthesis
Calculation of log risk ratios and their standard errors was repeated in Stata (StataCorp 2011). The log rate ratios and their standard errors were calculated in Stata (using the 'network setup' command; White 2012). Values of zero incidences were replaced with 0.1 for MTM.
MTM quality and inconsistency assessments
Risk of bias assessment within the MTM analyses was undertaken following the principles of the GRADE approach (Schunemann 2011) across the domains of risk of bias, indirectness, inconsistency and imprecision. Network diagrams were developed to display the network of interventions using nodes and edges. Nodes represented the competing treatments; the size of the shapes drawn over the nodes was proportionate to the number of studies where that intervention was evaluated. The edges represented the available direct comparisons between pairs of treatments; the thickness of the edges is weighted by the total number of devices/patients randomised in that comparison; colour indicated average level of study limitation due to bias (green=low, yellow=moderate, red=high) (Chaimani 2013). Contributions matrices (not presented) were used to identify the most influential comparisons for the network, and to evaluate the quality of evidence for the ranking of treatments. Based on the bias level (shown with coloured edges on the network plot) of the most influential comparisons, a decision was made to downgrade the overall confidence (in the overall ranking of interventions) for reasons of study limitations, or not to downgrade (Salanti 2014).
Indirectness due to differences between study populations, interventions and outcome measures resulting in a lack of transitivity was also assessed, resulting in further downgrading of confidence where necessary (Salanti 2014). Inconsistency refers to a disagreement between direct and indirect evidence, and overall confidence in the ranking of interventions was downgraded if there was evidence of inconsistency and/or the overall (common) heterogeneity was moderate / high. Inconsistency was assessed with 'ifplot' in Stata, and was evident at p<0.05. If the mean RoR is large (e.g. >2), this indicated possible inconsistency even if p>0.05 (Chaimani 2013). A common heterogeneity was used for all comparisons within each loop. The level of common heterogeneity was considered low at τ2<0.045 and high at τ2>1.14 (Salanti 2014), except at networks without loops. In this case the I2 statistic was calculated and assessed for intervention pairs (with direct evidence and more than one study) as low (<25%), moderate (25‐75%) or high (>75%). Rankings (by probabilities of being the best intervention) were produced using 'network rank' in Stata after running the consistency model ('network meta c' in Stata; White 2012). Confidence in the overall ranking was considered initially as ‘high’, and then later downgraded to ‘moderate’, ‘low’ and ‘very low’ as required.
Subgroup analysis and investigation of heterogeneity
We planned the following subgroup analyses for the primary outcomes, but were unable to complete them due to insufficient data within each pair‐wise comparison.
Adult participants versus paediatric participants versus neonatal participants.
Participants diagnosed with haematology/oncology conditions versus other participants.
CVC type (tunnelled versus non‐tunnelled, short‐term versus long‐term, dialysis versus non‐dialysis, PICC versus centrally‐inserted CVC).
Participants receiving the intervention in an acute versus a community setting.
Participants receiving lipid and parenteral nutrition (PN) versus patients not receiving lipid and PN.
Sensitivity analysis
We planned to perform a sensitivity analysis of primary outcomes to explore the effects of excluding those studies at high risk of bias from the final meta‐analysis. We planned only to include studies that were assessed as having a low risk of bias in all key domains, namely, adequate generation of the randomisation sequence, adequate allocation concealment, and blinding of outcome assessor, for the estimates of treatment effect. However we were unable to perform this analysis for the outcome of catheter‐related BSI due to poor reporting. There were insufficient studies in the other comparisons to permit a meaningful analysis on the remaining intervention comparisons.
Results
Description of studies
Results of the search
The results of the search and selection of studies are summarised in the PRISMA study flow diagram Figure 1. The search of electronic bibliographic databases identified 415 records, 69 of which were duplicates. Searches of clinical trial registries did not identify additional studies, but the handsearching of bibliographies identified three studies for potential inclusion. Of the 349 titles screened, 305 were excluded. We screened 44 full‐text articles for potential inclusion, and excluded 21, listing the reasons for their exclusion in the Characteristics of excluded studies tables. We identified four studies which we have not yet retrieved in full text or are awaiting information from the trial authors (Broadhurst 2014; Calvino 2014; Gu 2014; Pedrolo 2014).
1.

Study flow diagram.
Included studies
The 22 included studies, with a total of 7436 participants, are described in Characteristics of included studies. The studies were RCTs conducted in 25 countries, including the USA (five studies), Canada (three studies), France and Australia (two studies each), Greece, Italy, New Zealand, Spain, Turkey, Sweden, Israel, Brazil, Germany and the Netherlands (one study each).
Population and setting
Studies were undertaken in intensive care units (ICUs; Arvaniti 2012; Carrer 2005; Garland 2001; Hill 2010; Levy 2005; Nikoletti 1999; Pedrolo 2011; Roberts 1998; Timsit 2009; Timsit 2012), oncology and haematology units (Chambers 2005; Olson 2004; Ruschulte 2009; Shivnan 1991), including bone marrow transplantation units (Brandt 1996), haemodialysis centres (de Barros 2009; Hagerstrom 1994; le Corre 2003), general surgical units (Giles 2002; Wille 1993; Yamamoto 2002), and throughout the hospital (Conly 1989). One study continued to study participants after discharge from acute care (le Corre 2003).
Eleven studies restricted participation to adults (Arvaniti 2012; Brandt 1996; Chambers 2005; le Corre 2003; Nikoletti 1999; Olson 2004; Pedrolo 2011; Timsit 2009; Timsit 2012; Wille 1993; Yamamoto 2002); one study to paediatric participants (Levy 2005); two studies to neonates (Garland 2001; Hill 2010); while two studies had a combination of adults and children (Conly 1989; Shivnan 1991). The age of participants was not described in six studies (Carrer 2005; de Barros 2009; Giles 2002; Hagerstrom 1994; Roberts 1998; Ruschulte 2009).
The types of CVCs studied were restricted to tunnelled CVCs in four studies (Brandt 1996; Chambers 2005; Hagerstrom 1994; le Corre 2003), non‐tunnelled, percutaneous CVCs in six studies (Carrer 2005; Levy 2005; Nikoletti 1999; Pedrolo 2011; Roberts 1998; Ruschulte 2009), peripherally inserted central catheters (PICCs) in two studies (Hill 2010; Yamamoto 2002), and a combination of CVC types in four studies (Conly 1989; Garland 2001; Timsit 2009; Timsit 2012). The type of CVC investigated was not described in six studies (Arvaniti 2012; de Barros 2009; Giles 2002; Olson 2004; Shivnan 1991; Wille 1993).
Interventions and comparisons
As expected, the studies included many different interventions and comparisons. Researchers compared:
sterile gauze with standard polyurethane (SPU) in nine studies (Brandt 1996; Carrer 2005; Conly 1989; de Barros 2009; Giles 2002; Hagerstrom 1994; le Corre 2003; Pedrolo 2011; Shivnan 1991);
SPU with chlorhexidine gluconate‐impregnated (CGI) dressings in six studies (Arvaniti 2012; Garland 2001; Levy 2005; Roberts 1998; Ruschulte 2009; Timsit 2009);
SPU with silver‐impregnated dressings in one study (Hill 2010);
SPU with hydrocolloidal dressing in one study (Nikoletti 1999);
second generation gaseous permeability SPU with first generation SPU (old generation SPU) in one study (Wille 1993);
SPU, highly adhesive transparent dressings with CGI dressings in one study (Timsit 2012)
SPU with sutureless securement devices (SSD) in one study (Yamamoto 2002);
sterile gauze with no dressing in one study (Olson 2004); and
CGI dressings with no dressing in one study (Chambers 2005).
Outcomes
There was variability in the reporting of outcomes. The primary outcome of catheter‐related BSI was reported by 17 studies (Arvaniti 2012; Brandt 1996; Chambers 2005; Conly 1989; de Barros 2009; Garland 2001; Giles 2002; Hagerstrom 1994; le Corre 2003; Olson 2004; Pedrolo 2011; Ruschulte 2009; Shivnan 1991; Timsit 2009; Timsit 2012; Wille 1993; Yamamoto 2002). Each of these studies defined the outcome of catheter‐related BSI in accordance with the definition of our review. Several other studies reported catheter infection or sepsis, but did not meet the definition as described in our protocol, these studies are described in Characteristics of excluded studies.
Eight studies reported the patient day information required for our secondary outcome of 'frequency of catheter‐related BSI per 1000 patient days' (Arvaniti 2012; Chambers 2005; le Corre 2003; Ruschulte 2009; Timsit 2009; Timsit 2012; Wille 1993; Yamamoto 2002). We attempted to contact the remaining eight study authors who had provided catheter‐related BSI incidence in the pair wise comparisons, one provided patient day information (de Barros 2009), two were unable to locate the data (Olson 2004; Shivnan 1991), two did not respond (Garland 2001; Pedrolo 2011), and contact information could not be found for the remaining three (Brandt 1996; Giles 2002; Hagerstrom 1994).
The remaining secondary outcomes were reported inconsistently. Twelve studies reported the incidence of catheter tip colonisation according to our definitions (Arvaniti 2012; Carrer 2005; Conly 1989; de Barros 2009; Garland 2001; Giles 2002; Levy 2005; Nikoletti 1999; Pedrolo 2011; Roberts 1998; Timsit 2009; Timsit 2012). Two studies reported the incidence of skin or site colonisation according to our protocol definitions (Giles 2002; Shivnan 1991). The incidence of entry‐ and exit‐site infection was reported by four studies (Brandt 1996; Chambers 2005; Roberts 1998; Shivnan 1991), skin irritation or damage was reported by five studies (Garland 2001; Hill 2010; Levy 2005; Pedrolo 2011; Yamamoto 2002), incidence of failed catheter security by four studies (Arvaniti 2012; Brandt 1996; de Barros 2009; Yamamoto 2002), and mortality from any cause by four studies (Arvaniti 2012; Chambers 2005; Hill 2010; Pedrolo 2011). The incidence of dressing durability or condition was assessed using an a priori definition by one study (Pedrolo 2011), however no studies reported a mean score for dressing condition or durability using a formal assessment tool.
Due to the small number of studies that reported each outcome, clustering comparisons were only undertaken for catheter‐related BSI, and medication‐impregnated dressings (CGI, povidone‐iodine and silver‐impregnated) versus non‐impregnated dressings (SPU, BPU, gauze and tape, hydrocolloid).
Excluded studies
We excluded 21 studies for the following reasons.
Study design: the studies were clinical controlled studies, with sequential assignment rather than randomised allocation (two studies).
Population: arterial catheters and CVCs recruited to the studies, outcomes reported together. We contacted the study authors, but they were unable to provide separated results (two studies).
Confounding interventions: the study involved the application of specific dosages of skin antiseptics and administration set changes at different intervals that may have had a significant impact on the outcome results (one study).
Outcome definition: outcomes used in the study did not meet our outcome definitions (16 studies).
Inadequate data for extraction: the data were not provided in a way that allowed meaningful extraction, and we were unable to contact study authors (one study).
A description of each study is available in the Characteristics of excluded studies table (Crawford 2004; Davidson 1986; Freiberger 1992; George 2011; Keenlyside 1991; Keenlyside 1993; Khattak 2010; Lawson 1986; Little 1998; Lucas 1996; Madeo 1998; Maki 1984; Maki 2000; Neufeld 1991; Olson 2008; Petrosino 1988; Powell 1982; Powell 1985; Reynolds 1997; Schwebel 2012; Timsit 2010).
Risk of bias in included studies
Figure 2 shows that there is no evidence of funnel plot asymmetry to indicate potential reporting bias in the included studies.We judged that the majority of the studies had an unclear risk of bias for most criteria; Figure 3 presents the overall risk of bias. The characteristics of individual studies are summarised in the Characteristics of included studies tables. We did not downgrade the quality of the evidence for unclear risk of bias.
2.

Funnel plot of comparison: 1 Primary analysis, outcome: 1.1 Catheter‐related blood stream infection.
3.

Risk of bias summary: review authors' judgements about each risk of bias item for each included study.
Allocation
Nine of the 22 included studies described an adequate method of sequence generation (Arvaniti 2012; Garland 2001; le Corre 2003; Levy 2005; Nikoletti 1999; Olson 2004; Timsit 2009; Timsit 2012; Yamamoto 2002). An adequate method of allocation concealment was reported in only two of the studies (Garland 2001; Yamamoto 2002).
Blinding
No study blinded personnel or participants, as this was not achievable due to the visibility of the intervention. Only six studies reported blinding the outcome assessor (Arvaniti 2012; de Barros 2009; Nikoletti 1999; Ruschulte 2009; Timsit 2009; Timsit 2012).
Incomplete outcome data
Five studies provided incomplete outcome data with high percentages of undescribed attrition and loss‐to‐follow up (Carrer 2005; Conly 1989; le Corre 2003; Levy 2005; Roberts 1998). Seven studies reported complete outcome data (Arvaniti 2012; Giles 2002; Hill 2010; Pedrolo 2011; Ruschulte 2009; Timsit 2009; Timsit 2012). The remaining studies provided inadequate information to ascertain attrition bias.
Selective reporting
Protocols were available for two studies that had been registered in clinical trial registries (Timsit 2009; Timsit 2012). Five studies did not provide some of their outcomes per interventional group (Carrer 2005; Chambers 2005; Conly 1989; Olson 2004; Roberts 1998)
Other potential sources of bias
Five of the studies were sponsored by product manufacturers (Garland 2001; Shivnan 1991; Timsit 2012; Wille 1993; Yamamoto 2002). Three studies described systematic differences between the intervention and control groups at baseline (Arvaniti 2012; Conly 1989; Hill 2010), while three studies provided no participant baseline data, only CVC information (Hagerstrom 1994; Pedrolo 2011; Wille 1993). The majority of the included RCTs randomised participants and not their CVCs. Two studies recruited participants multiple times for multiple CVCs (Carrer 2005; Chambers 2005). One study stopped early for unknown reasons (Olson 2004).
Effects of interventions
See: Table 1; Table 2; Table 3
Summary of findings for the main comparison. Gauze and tape compared to standard polyurethane (SPU) for CVC dressing and securement.
| Gauze and tape compared to SPU for CVC dressing and securement | ||||||
| Patient or population: patients with CVC Setting: all settings Intervention: gauze and tape Comparison: standard polyurethane (SPU) | ||||||
| Outcomes | Anticipated absolute effects* (95% CI) | Relative effect (95% CI) | № of participants (studies) | Quality of the evidence (GRADE) | Comments | |
| Risk with standard polyurethane (SPU) | Risk with Gauze and tape | |||||
| Catheter‐related blood stream infection assessed with: as defined by criteria specified by Maki 2006; Mermel 2009 and O'Grady 2002 | Study population | RR 0.64 (0.26 to 1.63) | 506 (8 RCTs) | ⨁⨁◯◯ LOW 1 2 | ||
| 75 per 1000 | 48 per 1000 (19 to 122) | |||||
| Moderate | ||||||
| 113 per 1000 | 72 per 1000 (29 to 184) | |||||
| Catheter tip colonisation assessed with: positive semi‐quantitative (>15 cfu/catheter segment" or quantitative (>10 3 cfu/catheter segment" culture from a proximal or distal catheter segment (O'Grady 2002) | Study population | RR 0.95 (0.51 to 1.77) | 342 (5 RCTs) | ⨁◯◯◯ VERY LOW 2 3 4 | ||
| 413 per 1000 | 392 per 1000 (211 to 731) | |||||
| Moderate | ||||||
| 619 per 1000 | 588 per 1000 (316 to 1000) | |||||
| *The risk in the intervention group (and its 95% confidence interval) is based on the assumed risk in the comparison group and the relative effect of the intervention (and its 95% CI). CI: Confidence interval; RR: Risk ratio; OR: Odds ratio; | ||||||
| GRADE Working Group grades of evidence High quality: We are very confident that the true effect lies close to that of the estimate of the effect Moderate quality: We are moderately confident in the effect estimate: The true effect is likely to be close to the estimate of the effect, but there is a possibility that it is substantially different Low quality: Our confidence in the effect estimate is limited: The true effect may be substantially different from the estimate of the effect Very low quality: We have very little confidence in the effect estimate: The true effect is likely to be substantially different from the estimate of effect | ||||||
1 Downgraded due to wide 95% confidence intervals (0.26 to 1.63) 2 Downgraded due to variability in results between studies 3 Downgraded due to outcome being a surrogate measure of catheter‐related bloodstream infection 4 Downgraded due to wide 95% confidence intervals (0.51 to 1.77)
Summary of findings 2. Chlorhexidine gluconate‐impregnated (CGI) dressing compared to SPU dressings for CVC dressing and securement.
| Chlorhexidine gluconate‐impregnated (CGI) impregnated dressings compared to SPU dressing for central venous catheter (CVC) securement and dressing | ||||||
| Patient or population: patients with CVCs Setting: all settings Intervention: CGI dressing Comparison: SPU dressings | ||||||
| Outcomes | Anticipated absolute effects* (95% CI) | Relative effect (95% CI) | № of participants (studies) | Quality of the evidence (GRADE) | Comments | |
| Risk with SPU dressings | Risk with Chlorhexidine gluconate‐impregnated (CGI) dressing | |||||
| Catheter‐related blood stream infection assessed with: as defined by criteria specified by Maki 2006; Mermel 2009 and O'Grady 2002 |
Study population | RR 0.65 (0.40 to 1.05) | 4876 (5 RCTs) | ⨁⨁⨁◯ MODERATE 1 | ||
| 30 per 1000 | 19 per 1000 (12 to 31) | |||||
| Moderate | ||||||
| 18 per 1000 | 12 per 1000 (7 to 19) | |||||
| Catheter tip colonisation: assessed with: positive semi‐quantitative (>15 cfu/catheter segment" or quantitative (>10 3 cfu/catheter segment" culture from a proximal or distal catheter segment (O'Grady 2002) |
Study population | RR 0.58 (0.47 to 0.73) | 4431 (6 RCTs) | ⨁⨁⨁◯ MODERATE 2 | ||
| 147 per 1000 | 85 per 1000 (69 to 108) | |||||
| Moderate | ||||||
| 268 per 1000 | 155 per 1000 (126 to 196) | |||||
| *The risk in the intervention group (and its 95% confidence interval) is based on the assumed risk in the comparison group and the relative effect of the intervention (and its 95% CI). CI: Confidence interval; RR: Risk ratio; OR: Odds ratio; | ||||||
| GRADE Working Group grades of evidence High quality: We are very confident that the true effect lies close to that of the estimate of the effect Moderate quality: We are moderately confident in the effect estimate: The true effect is likely to be close to the estimate of the effect, but there is a possibility that it is substantially different Low quality: Our confidence in the effect estimate is limited: The true effect may be substantially different from the estimate of the effect Very low quality: We have very little confidence in the effect estimate: The true effect is likely to be substantially different from the estimate of effect | ||||||
1 Downgraded due to low rate of events and wide 95% confidence intervals 2 Downgraded due to outcome being a surrogate measure of catheter‐related bloodstream infection
Summary of findings 3. Medication‐impregnated dressings compared to all other dressing types for central venous catheter (CVC) dressing and securement.
| Medication‐impregnated dressings compared with all other dressing types for CVC dressing and securement | ||||||
| Patient or population: patients with CVCs Setting: all settings Intervention: medication‐impregnated dressings Comparison: all other dressing types | ||||||
| Outcomes | Anticipated absolute effects* (95% CI) | Relative effect (95% CI) | № of participants (studies) | Quality of the evidence (GRADE) | Comments | |
| Risk with all other dressing types | Risk with Medication‐impregnated dressings | |||||
| Catheter‐related blood stream infection assessed with: as defined by criteria specified by Maki 2006; Mermel 2009 and O'Grady 2002 | Study population | RR 0.60 (0.39 to 0.93) | 5687 (6 RCTs) | ⨁⨁⨁⨁ HIGH | ||
| 28 per 1000 | 17 per 1000 (11 to 26) | |||||
| Moderate | ||||||
| 64 per 1000 | 38 per 1000 (25 to 59) | |||||
| *The risk in the intervention group (and its 95% confidence interval) is based on the assumed risk in the comparison group and the relative effect of the intervention (and its 95% CI). CI: Confidence interval; RR: Risk ratio; OR: Odds ratio; | ||||||
| GRADE Working Group grades of evidence High quality: We are very confident that the true effect lies close to that of the estimate of the effect Moderate quality: We are moderately confident in the effect estimate: The true effect is likely to be close to the estimate of the effect, but there is a possibility that it is substantially different Low quality: Our confidence in the effect estimate is limited: The true effect may be substantially different from the estimate of the effect Very low quality: We have very little confidence in the effect estimate: The true effect is likely to be substantially different from the estimate of effect | ||||||
The main results are displayed in Table 1(gauze and tape compared with SPU), Table 2 (CGI compared with SPU) and Table 3(medication impregnated dressings compared with all other dressing types).
1.1 Incidence of catheter‐related bloodstream infection (BSI)
Analysis 1.1 displays the results of the meta‐analysis for catheter‐related BSI for the pair‐wise comparisons.
1.1.1 Gauze and tape compared with standard polyurethane (SPU) dressings (eight trials, 506 participants)
Eight studies in adult bone marrow transplantation units (101), haemodialysis (138), gastroenterological (72), adult ICU (21), paediatric and adult oncology (98) and general ward (76) settings reported this intervention and outcome, with 28 participants out of a total of 506 developing a catheter‐related BSI (Brandt 1996; Conly 1989; de Barros 2009; Giles 2002; Hagerstrom 1994; le Corre 2003; Pedrolo 2011; Shivnan 1991). There was no clear difference between gauze and tape and SPU dressings on the incidence of catheter‐related BSI (RR 0.64, 95% CI 0.26 to 1.63; Analysis 1.1). Low quality evidence (downgraded for inconsistency and imprecision). Statistical heterogeneity was low but point estimates cross the line (Chi² 6.82; P value 0.34; I² 12%).See Table 1.
1.1.2 Gauze and tape compared with no dressings (one trial, 78 participants)
One small study in an adult oncology setting (Olson 2004) reported on the effect of gauze and tape compared with no dressings and found no clear difference in the incidence of catheter‐related BSI (RR 1.47, 95% CI 0.72 to 3.00) however this study was too small to detect a difference should it exist. Low quality evidence (downgraded for risk of bias and imprecision)
1.1.3 SPU dressings compared with old generation SPU dressings (one trial, 101 participants)
One small study in an adult surgical setting (Wille 1993) found clear difference in the incidence of catheter‐related BSI between SPU dressings and "old generation" SPU dressings (RR 0.33, 95% CI 0.04 to 3.04) however because this study was so small we cannot be confident that a difference does not exist. Low quality evidence (downgraded for imprecision)
1.1.4 Highly adhesive transparent dressing compared with SPU dressings (one trial, 982 participants)
One study in an adult ICU setting (Timsit 2012) found no clear difference in catheter‐related BSI between a highly adhesive transparent dressing and SPU dressings (RR 0.60, 95% CI 0.20 to 1.77). Moderate quality evidence (downgraded for imprecision)
1.1.5 Chlorhexidine gluconate‐impregnated (CGI) dressings compared with SPU dressing (five trials, 4876 participants)
We pooled five trials (Arvaniti 2012; Garland 2001; Ruschulte 2009; Timsit 2009; Timsit 2012) comparing CGI with SPU dressings. It is unclear whether CGI dressings reduce the risk of catheter‐related BSI compared with SPU dressings as although there was a reduction in risk of catheter‐related BSI this did not reach traditional levels of statistical significance (P=0.08) (RR 0.65, 95%, CI 0.40 to 1.05; Analysis 1.1.2) (moderate quality evidence, downgraded for imprecision). Five studies in adult ICU (3620), neonatal ICU (705) and adult haematology/oncology (601) units/wards reported this intervention and outcome, with 106 participants out of 4876 developing a catheter‐related BSI . Statistical heterogeneity was low (Chi² 5.38; P value 0.25; I² 26%). See Table 2.
1.1.6 CGI dressing compared with highly adhesive transparent dressing (one trial, 1453 participants)
One study (adult ICU) found no clear difference in the incidence of catheter‐related BSI (Timsit 2012) between CGI dressings and a highly adhesive transparent dressing (RR 0.48, 95% CI 0.14 to 1.66). Moderate quality evidence (downgraded for imprecision)
1.1.7 SPU dressings compared with hydrocolloid dressings (one trial, 128 participants)
There were fewer cases of catheter‐related BSI with SPU dressings than hydrocolloid dressings in a single study in adult ICU (Nikoletti 1999) (RR 0.53, 95% CI 0.29 to 0.97). Moderate quality evidence (downgraded for imprecision)
1.1.8 SPU dressings compared with sutureless securement devices (one trial, 170 participants)
There were fewer cases of catheter‐related BSI with sutureless securement devices than SPU in a single study in adult general acute and home care settings (Yamamoto 2002) (RR 8.00, 95% CI 1.02 to 62.58, P value 0.05). Low quality evidence (downgraded for risk of bias and imprecision).
1.1.9 CGI dressing compared with no dressing (one trial, 112 participants)
There was no clear difference in the incidence of catheter‐related BSI between CGI dressings and no dressing in one small study (RR 0.27, 95% CI 0.06 to 1.22). This study was based in an adult haematology setting (Chambers 2005). Moderate quality evidence (downgraded for imprecision)
1.1.10 Medication‐impregnated dressings compared with all others (six trials, 5687 participants)
Six studies from adult ICU (4269), neonatal ICU (705) and adult haematology/oncology (713) settings reported this intervention and outcome; 124 participants out of a total of 5687 developed a catheter‐related BSI (Arvaniti 2012; Chambers 2005; Garland 2001; Ruschulte 2009; Timsit 2009; Timsit 2012). There was high quality evidence that medication‐impregnated dressings reduce the risk of catheter‐related BSI compared with all other dressings (RR 0.60, 95% CI 0.39 to 0.93; P value 0.02) (Analysis 1.1). Statistical heterogeneity was low (Chi² 6.21; P value 0.29; I² 19%). See Table 3.
1.2 Frequency of catheter‐related bloodstream infection per 1000 patient days
Analysis 1.2 presents the results of the meta‐analysis for catheter‐related BSI per 1000 patient days for the pair‐wise comparisons.
1.2. Analysis.

Comparison 1 Primary analysis, Outcome 2 Frequency of catheter‐related BSI per 1000 patient days.
1.2.1 Gauze and tape compared with SPU dressings (two trials, 8538 patient days)
Two studies in haemodialysis settings reported this intervention and outcome, with 10 participants out of a total of 8538 patient days developing a catheter‐related BSI (de Barros 2009; le Corre 2003). There was no clear evidence of a difference in the frequency of catheter ‐related BSI per 1000 patient days when gauze and tape was compared with SPU dressing (RR 0.71, 95% CI 0.20 to 2.52; Analysis 1.2). . Statistical heterogeneity was low (Chi² 0.37; P value 0.54; I² 0%). Moderate quality evidence (downgraded for imprecision)
1.2.2 SPU compared with old generation SPU (one trial, 780 patient days)
There was no clear difference in the frequency of catheter‐related BSI per 1000 patient days in a single study in an adult surgical setting (Wille 1993) when SPU was compared with old generation SPU (RR 0.35, 95% CI 0.01 to 18.61). Moderate quality evidence (downgraded for imprecision)
1.2.3 SPU compared with sutureless securement devices (one trial, 5730 patient days)
One study in general adult acute and home settings (Yamamoto 2002) found no difference between SPU and sutureless securement devices in the frequency of catheter‐related BSI per 1000 patient days (RR 0.13, 95% CI 0.00 to 5.82). Low quality evidence (downgraded for risk of bias and imprecision)
1.2.4 CGI dressings compared with SPU (four trials, 42,689 patient days)
The pooled results of four studies (in adult ICU; 32,958 patient days) and haematology/oncology; 9731 patient days) (Arvaniti 2012; Ruschulte 2009; Timsit 2009; Timsit 2012) show that CGI dressings reduce the frequency of catheter‐related BSI per 1000 patient days compared with SPU (RR 0.51, 95% CI 0.33 to 0.78, P value 0.002; Analysis 1.2). There was no statistical heterogeneity detected (Chi² 2.52; P value 0.47; I² 0%). Moderate quality evidence (downgraded for imprecision)
1.2.5 Highly adhesive transparent dressing compared with SPU (one trial, 8831 patient days)
One study in adult ICU (Timsit 2012) found no difference in the frequency of catheter‐related BSI per 1000 patient days between highly adhesive transparent dressings and SPU (RR 0.67, 95% CI 0.14 to 3.11). Moderate quality evidence (downgraded for imprecision)
1.2.6 CGI dressings compared with no dressing (one trial, 12,351 patient days)
One study in adult haematology (Chambers 2005) found no difference in the frequency of catheter‐related BSI per 1000 patient days between CGI dressings and no dressing (RR 3.98, 95% CI 0.76 to 20.91). Low quality evidence (downgraded for risk of bias and imprecision)
1.3 Incidence of catheter tip colonisation
Analysis 1.3 displays the results of the meta‐analysis for catheter tip colonisation for the pair‐wise comparisons.
1.3. Analysis.

Comparison 1 Primary analysis, Outcome 3 Catheter tip colonisation.
1.3.1 Gauze and tape compared with SPU dressings (five trials, 341 participants)
Five studies in haemodialysis (66), gastroenterological (72), adult ICU (127), and general ward (76) settings reported this intervention and outcome, with 99 participants out of a total of 341 having their CVC tip colonised (Carrer 2005; Conly 1989; de Barros 2009; Giles 2002; Pedrolo 2011). There was no clear difference in the risk of catheter tip colonisation between gauze and tape and SPU dressings (RR 0.95, 95% CI 0.51 to 1.77; Analysis 1.3). . See Table 1. Statistical heterogeneity was high (Chi² 12.06; P value 0.02; I² 67%). Very low quality evidence (downgraded for inconsistency, indirectness and imprecision)
1.3.2 CGI compared with SPU dressings (six trials, 4431 participants)
Pooling the results of six trials (Chi² 6.41; P value 0.27; I² 22%) showed that the risk of catheter tip colonisation is reduced with CGI compared with SPU dressings (RR 0.58, 95% CI 0.47 to 0.73; Analysis 1.3). Six studies reported this intervention and outcome, with 457 participants out of a total of 4431 having their CVC tip colonised (Arvaniti 2012; Garland 2001; Levy 2005; Roberts 1998; Timsit 2009; Timsit 2012). These results are also presented in Table 2. This analysis is based upon participants from adult ICU (3581), neonatal ICU (705) and paediatric ICU (145) settings. Moderate quality evidence (downgraded for indirectness)
1.3.3 Highly adhesive transparent dressing compared with SPU (one trial, 982 participants)
There was no difference in the incidence of catheter tip colonisation between highly adhesive transparent dressings and SPU (RR 1.32, 95% CI 0.88 to 1.98). This single study (Timsit 2012) was in an adult ICU setting. Low quality evidence (downgraded for imprecision and indirectness)
1.3.4 SPU compared with hydrocolloidal dressings (one trial, 128 participants)
One small study in adult ICU (Nikoletti 1999) found no difference in the incidence of catheter tip colonisation between SPU and hydrocolloid dressings (RR 1.88, 95% CI 1.03 to 3.42). Low quality evidence (downgraded for imprecision and indirectness)
1.4 Incidence of entry‐ and exit‐site infections
1.4.1 Gauze and tape compared with SPU dressings (two trials, 199 participants)
The pooled results of two studies (Brandt 1996; Shivnan 1991) comparing the use of gauze and tape with SPU dressings found no clear difference in the incidence of entry‐ and exit‐site infections (RR 0.84, 95% CI 0.34 to 2.07; Analysis 1.4; (Chi² 0.15; P value 0.69; I² 0%). These studies took place in adult bone marrow transplant unit (101) and paediatric and adult oncology (98) settings. Moderate quality evidence (downgraded for imprecision)
1.4. Analysis.

Comparison 1 Primary analysis, Outcome 4 Entry‐ and exit‐site infection.
1.4.2 SPU compared with CGI dressings (one trial, 33 participants)
A single small study in adult ICU (Roberts 1998) found no clear difference in the incidence of entry‐ and exit‐site infections between SPU and CGI dressings (RR 0.80, 95% CI 0.21 to 3.02). Low quality evidence (downgraded for risk of bias and imprecision)
1.4.3 CGI dressings compared with no dressing (one trial, 112 participants)
A single small study in an adult haematology setting (Chambers 2005) found fewer entry‐ and exit‐site infections with CGI than with no dressing (RR 0.20, 95% CI 0.06 to 0.66). Low quality evidence (downgraded for risk of bias and imprecision)
1.5 Incidence of skin or site colonisation
1.5.1 Gauze and tape compared with SPU dressings (two trials, 170 participants)
Two studies (Giles 2002; Shivnan 1991).compared gauze and tape with SPU in gastroenterology (72) and paediatric and adult oncology (98) settings. These studies were pooled ( I² 0%). There was no difference In the incidence of skin or site colonisation between gauze and tape and SPU dressing (RR 0.86, 95% CI 0.30 to 2.51; Analysis 1.5). Moderate quality evidence (downgraded for imprecision)
1.5. Analysis.

Comparison 1 Primary analysis, Outcome 5 Skin/site colonisation.
1.6 Incidence of skin irritation or damage
1.6.1 Gauze and tape compared with SPU dressings (one trial, 21 participants)
There was no clear evidence of difference in skin irritation or damage between gauze and tape and SPU in a single study (adult ICU) (Pedrolo 2011) (RR 6.60, 95% CI 0.95 to 45.75). Moderate quality evidence (downgraded for imprecision)
1.6.2 CGI compared with SPU (two trials, 850 participants)
There was no clear evidence of a difference in the incidence of skin irritation or damage between CGI dressings and SPU when two studies were pooled (Chi² 2.17; P value 0.14; I² 54%) (Garland 2001; Levy 2005) (RR 11.17, 95% CI 0.84 to 149.48; Analysis 1.6). These studies took place in neonatal ICU (705) and paediatric ICU (145) settings. Higher rates of skin irritation or damage were evidence in the neonatal than the paediatric population. Moderate quality evidence (downgraded for imprecision)
1.6. Analysis.

Comparison 1 Primary analysis, Outcome 6 Skin irritation or damage.
1.6.3 SPU compared with other medication‐impregnated dressings (one trial, 118 participants)
A single small study (Hill 2010) compared the effects of SPU and other medication‐impregnated dressings, in this case silver, on the rate of skin irritation or damage in neonatal ICU and found no difference (there was no irritation or skin damage in either group). Low quality evidence (downgraded for imprecision)
1.6.4 SPU compared with sutureless securement devices (SSD; one trial, 170 participants)
A single small study (Yamamoto 2002) found no difference in the incidence of skin irritation or damage between SPU and SSDs in general adult acute and home‐care settings. (RR 0.61, 95% CI 0.06 to 5.78). Low quality evidence (downgraded for risk of bias and imprecision)
1.7 Incidence of failed catheter securement
1.7.1 Gauze and tape compared with SPU dressing (two trials, 167 participants)
The pooled results of two studies (Brandt 1996; de Barros 2009) found no difference between gauze and tape and SPU dressings in the incidence of failed catheter securement (RR 0.90, 95% CI 0.33 to 2.49; Analysis 1.7). This analysis is based upon participants from adult BMT (101) and haemodialysis (66) settings. Statistical heterogeneity was absent (Chi² 0.54; P value 0.46; I² 0%). Moderate quality evidence (downgraded for imprecision)
1.7. Analysis.

Comparison 1 Primary analysis, Outcome 7 Failed catheter securement.
1.7.2 SPU compared with CGI dressings (one trial, 306 participants)
One study in adult ICU (Arvaniti 2012) compared SPU with CGI dressings and found no difference in the incidence of failed catheter securement (RR 2.40, 95% CI 0.47 to 12.20). Moderate quality evidence (downgraded for imprecision)
1.7.3 SPU compared with SSD (one trial, 170 participants)
One study in adult acute and home care settings compared (Yamamoto 2002) SPU with SSD and found no difference in the incidence of failed catheter securement (RR 1.20, 95% CI 0.55 to 2.63). Low quality evidence (downgraded for risk of bias and imprecision)
1.8 Dressing condition or durability
1.8.1 Gauze and tape compared with SPU dressing (one trial, 21 participants)
One very small study in adult ICU (Pedrolo 2011) compared gauze and tape with SPU and found no difference in dressing condition or durability (RR 0.57, 95% CI 0.10 to 3.27). Moderate quality evidence (downgraded for imprecision)
1.9 Mortality
1.9.1 Gauze and tape compared with SPU dressing (one trial, 21 participants)
One very small study in adult ICU (Pedrolo 2011) compared mortality in people receiving either gauze and tape or SPU and found no clear difference (RR 1.10, 95% CI 0.19 to 6.41). Moderate quality evidence (downgraded for imprecision)
1.9.2 SPU compared with CGI dressing (one trial, 606 participants)
One study in adult ICU (Arvaniti 2012) an increase in mortality with SPU compared with CGI dressing (RR 3.71, 95% CI 2.48 to 5.55). This study had a high mortality rate, with a total of 80 out of 606 participants dying. Moderate quality evidence (downgraded for imprecision)
1.9.3 SPU dressing compared with other medication‐impregnated dressing (one trial, 118 participants)
One study in neonatal ICU (Hill 2010) found no clear difference in mortality between SPU and other medication‐impregnated dressings (impregnated with silver) (RR 1.53, 95% CI 0.14 to 16.31). Low quality evidence (downgraded for risk of bias and imprecision)
1.9.4 CGI compared with no dressing (one trial, 112 participants)
One study in adult haematology (Chambers 2005) found no clear difference in mortality between CGI and no dressing (RR 1.33, 95% CI 0.55 to 3.25). Low quality evidence (downgraded for risk of bias and imprecision)
Sensitivity analyses
We planned sensitivity analyses for two major outcomes, catheter‐related BSI and catheter tip colonisation, to evaluate the impact of excluding studies based on the risks of selection and attrition bias. We were unable to perform the analyses on catheter‐related BSI, as poor reporting meant we were not able to identify those studies at high risk bias. We performed sensitivity analyses on catheter tip colonisation, for the comparison of CGI dressings versus SPU. There were insufficient studies for the other comparisons to permit a meaningful analysis to be performed.
2.1 Catheter tip colonisation
As described in Analysis 2.1, the exclusion of two studies (Levy 2005; Roberts 1998) with a high risk of attrition bias did not alter the pooled estimates substantially when we compared CGI dressings with SPU ('without' attrition bias: RR 0.59, 95% CI 0.46 to 0.77, compared to 'with' attrition bias: RR 0.58 95% CI 0.47 to 0.73).
2.1. Analysis.

Comparison 2 Sensitivity analysis: studies at low risk of bias, Outcome 1 Catheter tip colonisation.
Multiple treatments meta‐analysis
We undertook a multiple treatments meta‐analysis for each outcome for which more than two interventions were compared. These results are summarised graphically in the figures section.
3.1 Incidence of catheter‐related BSI
SSD had the highest probability of being the most effective intervention to reduce the incidence of catheter‐related BSI, followed by CGI (Figure 4). Low quality of evidence (downgraded due to moderate risk of bias, likely inconsistency and moderate common heterogeneity).
4.

.1 MTM Network plot: Incidence of catheter related bloodstream infection
SPU standard polyurethane, G+T gauze and tape, BPU bordered polyurethane, CGI chlorhexidine gluconate impregnated, NOD no dressing, SSD sutureless securement device, OLD old standard polyurethane, HAD highly adhesive dressing.
3.2 Frequency of catheter‐related BSI per 1000 patient days
"Old" SPU had the highest probability of being the most effective intervention to reduce the frequency of catheter‐related BSI per 1000 patient days, followed by CGI (Figure 5). Moderate quality of evidence (downgraded due to moderate risk of bias).
5.

3.2 MTM Network plot: Frequency of catheter‐related bloodstream infection per 1000 patient days
SPU standard polyurethane, G+T gauze and tape, CGI chlorhexidine gluconate impregnated, NOD no dressing, OLD old standard polyurethane, HAD highly adhesive dressing.
3.3 Incidence of catheter tip colonisation
CGI had the highest probability of being the most effective intervention to reduce the incidence of catheter tip colonisation, followed by gauze and tape (Figure 6). Moderate quality of evidence (downgraded due to moderate risk of bias).
6.

3.3 MTM Network plot: Incidence of catheter tip colonisation
SPU standard polyurethane, G+T gauze and tape, CGI chlorhexidine gluconate impregnated, HYD hydrocolloid, HAD highly adhesive dressing.
3.4 Incidence of entry‐ or exit‐site infection
Gauze and tape had the highest probability of being the most effective intervention to reduce the incidence of entry or exit site infection. No dressing had the lowest probability (Figure 7). Low quality of evidence (downgraded due to moderate risk of bias and low levels of transitivity (indirectness)).
7.

3.4 MTM Network plot: Incidence of entry‐ and exit‐ site infections
SPU standard polyurethane, G+T gauze and tape, CGI chlorhexidine gluconate impregnated, NOD no dressing.
3.5 Incidence of skin irritation or damage
SSD had the highest probability of being the most effective intervention to reduce the incidence of skin irritation or damage, followed by SPU (Figure 8). Low quality of evidence (downgraded due to moderate risk of bias, moderate heterogeneity (inconsistency)).
8.

3.5 MTM Network plot: Incidence of skin irritation or damage
SPU standard polyurethane, G+T gauze and tape, CGI chlorhexidine gluconate impregnated, SSD sutureless securement device, OTH other medication impregnated dressing
3.6 Incidence of failed catheter securement
Gauze and tape had the highest probability of being the best intervention to reduce the incidence of failed catheter securement, followed by SPU (Figure 9). Moderate quality of evidence (downgraded for moderate risk of bias).
9.

3.6 MTM Network plot: Incidence of failed catheter securement
SPU standard polyurethane, CGI chlorhexidine gluconate impregnated, SSD sutureless securement device,
3.7 Incidence of mortality
No dressing was associated with the highest probability of being the most effective intervention to reduce mortality, followed by CGI (Figure 10). Low quality of evidence (downgraded for moderate risk of bias, low levels of transitivity (indirectness)).
10.

3.7 MTM Netowrk plot: Mortality
SPU standard polyurethane, G+T gauze and tape, CGI chlorhexidine gluconate impregnated, NOD no dressing, OTH other medication impregnated dressing
Discussion
Summary of main results
CGI dressings may reduce catheter‐related blood stream infection relative to SPU and other dressings (moderate quality of evidence). This direction of effect is consistent for the outcomes of relative risk of catheter‐related blood stream infection, rates of blood stream infection per 1000 patient days and catheter tip colonisation however there is uncertainty around the result for the primary outcome of relative risk and no difference cannot be excluded. There is high quality evidence that the use of medication‐impregnated dressing products reduce the incidence of catheter‐related BSI in comparison with all other dressing types. The class of interventions termed 'medication‐impregnated dressings' included only CGI dressings in various forms (e.g. patch or whole dressing), whilst the 'all other dressing types' group involved SPU, highly adhesive transparent dressings and no dressing. There was moderate quality evidence for a reduction in the frequency of catheter‐related BSI per 1000 patient days with the use of CGI dressings, compared to SPU. There was also moderate quality evidence in the reduction in the risk of colonisation of the CVC tip with CGI dressings compared to SPU. Colonisation of the CVC tip is considered an indirect measure of catheter‐related BSI. Most studies were conducted in ICU settings (Analysis 1.1.2: 89% participants; Analysis 1.2.2: 77% catheter days; Analysis 1.3.2: 100% participants). The evidence for the effectiveness of CGI dressings is probably not generalisable beyond these settings.
The results of the multiple‐treatment meta‐analysis (MTM) are generally in agreement with the pair‐wise comparisons. CGI dressings were ranked as having the highest probability of reducing the incidence of catheter tip colonisation and second to SSD for reducing the incidence of catheter‐related BSI and frequency of catheter‐related BSI per 1000 patient days. The level of evidence reported in the MTM was of low to moderate quality, and further research may alter these results.
One large RCT comparing CGI and SPU dressings was excluded from this review (Maki 2000; 1401 participants); this RCT compared the effectiveness of CGI dressings with SPU for the securement and dressing of arterial catheters, pulmonary artery catheters and CVC. The trial found a significant reduction in the incidence of catheter‐related BSI for participants receiving CGI dressings (P value < 0.05). This study was excluded because the outcome data were not provided separately for catheter type. We contacted the study authors, but they were not able to provide us with the CVC outcomes. Exclusion of these results may have had a significant impact on the results of the meta‐analyses included in this review. If we had been able to include these data, it is highly likely that our estimates of effect for the incidence of catheter‐related BSI would have become significant and favoured CGI dressings compared to SPU.
There is some concern in the current literature regarding the increased risk of skin irritation or damage for CGI dressings. Our current analysis results were heavily influenced by a single study that examined 705 neonatal ICU participants (59.2% of participants in the meta‐analysis; Garland 2001). The majority of reactions occurred in neonates up to 28 weeks gestational age and up to 1000 g in weight. Local contact dermatitis from the CGI dressing may limit its use in acutely ill low‐birthweight neonates or others with impaired skin integrity (Garland 2001).
Overall completeness and applicability of evidence
We identified a large number of studies in which the population, intervention, comparison and outcomes matched our prespecified selection criteria. The studies were conducted in 25 different countries, in a range of settings and age‐related populations, with different CVC types. Despite this, the majority of dressing and securement products have not been adequately compared, due to the large variety that are currently available. This means that there is ongoing uncertainty regarding the effectiveness of several of the commercially and clinically available products. Additionally, several of our outcomes, that reported on skin or site colonisation and dressing durability, were poorly reported. CVC catheter security was not adequately addressed by the included studies. Considering the serious consequences associated with accidental CVC removal due to poor security, this is an outcome that needs to be investigated.
Quality of the evidence
Risk of bias was difficult to assess in most studies because of poor reporting. Since it was not possible to blind personnel or participants to the CVC dressing and securement product, there was a potential source of performance bias and staff or patients may have behaved differently given knowledge of the intervention; this seems unlikely however. Blinding of outcome assessors was feasible for the primary outcome, but was achieved and reported adequately by only six of the studies (Arvaniti 2012; de Barros 2009; Nikoletti 1999; Ruschulte 2009; Timsit 2009; Timsit 2012). Only two studies achieved and reported the minimisation of selection bias adequately via both random sequence generation and allocation concealment (Garland 2001; Yamamoto 2002). Several of the trials reported receiving partial or full manufacturer sponsorship (Garland 2001; Shivnan 1991; Timsit 2012; Wille 1993; Yamamoto 2002), however it is unclear whether this had an impact on the reported results. It is common within the field of intravascular device research for investigators to receive partial or full sponsorship for the completion of research. The funnel plot did not reveal any underlying positive or negative publication bias.
Potential biases in the review process
We followed clearly described procedures to prevent potential bias in the review process. The comprehensive search of multiple sources and the methods we used are transparent and reproducible. Claire Rickard and Amanda Ullman have received research funding from Centurion Medical Products (Williamston, MI) that is unrelated to this review; products manufactured by Centurion Medical Products are not included within this review. The other review authors have not reported any conflict of interest.
Agreements and disagreements with other studies or reviews
The previous version of this review 'Gauze and tape and polyurethane dressings for CVC' identified a four‐fold increase in the rate of catheter‐related BSI when a polyurethane dressing was used, compared with gauze and tape (Webster 2011). However, with the widening of the inclusion criteria to include recently published research and participants in community settings, this difference has ceased to be significant.
The Centres for Disease Control and Prevention (CDC) recommend the use of either a sterile gauze or SPU dressing to cover the CVC site (O'Grady 2011). By comparison, 'epic3', the English national evidence‐based guidelines (Loveday 2014), recommend the use of SPU, unless the insertion site is perspiring profusely or the insertion site is bleeding or leaking. Both the CDC and epic3 guidelines advocate the use of a CGI dressing as a strategy to reduce catheter‐related BSI, but CDC recommend CGI dressings only for temporary short‐term catheters in patients over two months of age and then only if the central line‐associated BSI rate is not decreasing despite adherence to basic prevention methods.
Our review suggests that catheter‐related BSI may be reduced with CGI compared with SPU, and that the risk of catheter‐related BSI is reduced with medication‐impregnated dressings compared with all others. Additionally, we identified a reduction in the incidence of catheter tip colonisation when using a CGI dressing compared to SPU. A previous meta‐analyses, Ho 2006, that compared the effectiveness of CGI dressings to SPU for intravascular and epidural catheters had similar results. That meta‐analysis identified a significant reduction in intravascular catheter or exit‐site bacterial colonisation for CGI dressings compared to SPU (14.8% versus 26.9%; odds ratio (OR) 0.47, 95% CI 0.34 to 0.65; P value < 0.00001) and a trend towards a reduction in intravascular catheter‐related BSI or central nervous system infection (2.2% versus 3.8%; OR 0.58, 95% CI 0.29 to 1.14; P value 0.11). Participants who had their intravascular and epidural catheters dressed with a CGI dressing had a significantly increased rate of local cutaneous reactions in comparison to those dressed with SPU (OR 8.17, 95% CI 1.19 to 56.14, P value 0.04), and the majority of these reactions occurred in neonatal patients.
A recent meta‐analysis, Safdar 2014, evaluated the efficacy of CGI dressing compared to 'conventional' dressings for CVC, pulmonary artery or peripheral arterial catheters. This analysis identified that the use of a CGI dressing compared to a 'conventional' dressing reduced the risk of catheter‐related BSI (RR 0.60, 95% CI 0.41 to 0.88; P value 0.009) and catheter colonisation (RR 0.52, 95% CI 0.43 to 0.64; P value < 0.001). These results agree with this review, even with the inclusion of pulmonary artery and arterial catheters, in addition to CVC.
Authors' conclusions
Implications for practice.
There is some evidence that chlorhexidine‐impregnated (CGI) dressings used for securing central venous catheters may reduce the risk of catheter‐related BSI, compared with standard polyurethane (SPU) dressings and other (non‐impregnated) dressing types. This evidence mainly comes from intensive care unit settings.
The evidence for the relative effects of different dressing and securement comparisons, including gauze and tape versus SPU, on catheter tip colonisation and catheter‐related BSI is unclear.
There was inadequate research to permit us to make recommendations about CVC security using the different dressing and securement products.
Implications for research.
More, high quality research is needed regarding the relative effects of dressing and securement products for CVCs. New products are continually becoming commercially available, and researchers need to provide the evidence to inform clinical decision making in this area. Clinically important outcomes including CVC security, have not been adequately addressed by current research.
Future research may adjust the estimates of effect for the products included in this review. Researchers should plan their protocols so that the risk of bias in each domain is minimised and should report trials clearly in accordance with the CONSORT guidelines (Schulz 2010).
Feedback
Feedback from Tom Macmillan, Information Specialist, 11 August 2016
Summary
Comment: I believe there is an error in your analysis in section 1.1.8. The text states:
"There were fewer cases of catheter‐related BSI with SPU than sutureless securement devices in a single study in adult general acute and home care settings."
This references Yamamto et al. (2002); however, looking at the original paper the result is the complete opposite. They found fewer suspected and confirmed cases of CRBSI with the sutureless securement device (both statistically significant results).
Although this is not the main focus of the study, I think it probably merits a correction.
Reply
Many thanks to Tom MacMillan for alerting us to an error when summarising the results of a single study (Yamamoto 2002) included within our review examining central venous catheter dressing and securement. The data from this study were correctly included within each of the network meta‐analyses, however the individual results within the outcome of catheter‐related BSI were inverted. We have now corrected this mistake within the appropriate results section of the text. We wish to apologise for any confusion caused.
Contributors
Amanda Ullman, Author.
History
Protocol first published: Issue 2, 2013 Review first published: Issue 9, 2015
| Date | Event | Description |
|---|---|---|
| 28 September 2016 | Feedback has been incorporated | Feedback submitted and author response added to the review. |
Acknowledgements
The authors would like to thank Sally Bell‐Syer, (Managing Editor, Cochrane Wounds Review Group), Ruth Foxlee and Amanda Briant (Trial Search Co‐ordinators, Cochrane Wounds Review Group) and Susan O'Meara (editor) for their assistance in preparation of this review.The authors would like to acknowledge the contribution of the peer, statistical, methodological and consumer referees: Donna Gillies, Liz Bckerdike, Evangelos Kontopantelis and Janet Gunderson. The National Health and Medical Research Council (NH&MRC) has provided funding for this review from its Centre of Research Excellence scheme, which funds one or more of the authors.
Appendices
Appendix 1. Types of central venous catheters (CVCs) used
| Catheter type | Entry site | Length |
| Non‐tunnelled central venous catheters | Percutaneously inserted into central veins (subclavian, internal jugular or femoral) | ≥ 8 cm depending on patient size |
| Peripherally inserted central venous catheters (PICC) | Inserted into basilic, cephalic or brachial veins and enter the superior vena cava | ≥ 20 cm depending on patient size |
| Tunnelled central venous catheters | Implanted into subclavian, internal jugular, or femoral veins | ≥ 8 cm depending on patient size |
| Totally implantable | Tunnelled beneath skin and have subcutaneous port accessed with a needle; implanted in subclavian or internal jugular vein | ≥ 8 cm depending on patient size |
O'Grady 2011 pg. 22
≥ = greater than or equal to
Appendix 2. Additional search strategy
Ovid MEDLINE
1 exp Catheterization, Central Venous/ (12023) 2 (venous adj3 (catheter* or line*)).tw. (12967) 3 (central adj3 (catheter* or line*)).tw. (12809) 4 ((hickman or broviac or cook) adj catheter*).tw. (667) 5 exp Catheters, Indwelling/ (16113) 6 (implantable vascular access device or IAVD or PortACath).tw. (58) 7 (peripherally inserted central catheter or PICC).tw. (585) 8 h?emodialysis catheter*.tw. (762) 9 or/1‐8 (34316) 10 exp Occlusive Dressings/ (3511) 11 exp Bandages, Hydrocolloid/ (631) 12 exp Silver/ (14667) 13 exp Silver Sulfadiazine/ (809) 14 exp Polyurethanes/ (7439) 15 exp Iodine/ (18302) 16 exp Chlorhexidine/ (6308) 17 ((occlusive* or hydrocolloid* or silver* or polyurethane* or permeable or nonpermeable or non‐permeable or transparent or chlorhexidine or iodine* or gauze or tape) adj3 (dressing* or sponge*)).tw. (2517) 18 or/10‐17 (51952) 19 9 and 18 (748) 20 randomized controlled trial.pt. (387973) 21 controlled clinical trial.pt. (89778) 22 randomi?ed.ab. (340534) 23 placebo.ab. (150625) 24 clinical trials as topic.sh. (173007) 25 randomly.ab. (200735) 26 trial.ti. (123439) 27 or/20‐26 (904765) 28 exp animals/ not humans.sh. (4009223) 29 27 not 28 (832096) 30 19 and 29 (224) 31 2014*.ed. (584053) 32 30 and 31 (3)
Ovid EMBASE
1 exp central venous catheter/ (12794) 2 exp central venous catheterization/ (7021) 3 (venous adj3 (catheter* or line*)).tw. (18144) 4 (central adj3 (catheter* or line*)).tw. (19024) 5 ((hickman or broviac or cook) adj catheter*).tw. (776) 6 exp vascular access device/ (12794) 7 (implantable vascular access device or IAVD or PortACath).tw. (102) 8 (peripherally inserted central catheter or PICC).tw. (1340) 9 h?emodialysis catheter*.tw. (1069) 10 or/1‐9 (31589) 11 exp occlusive dressing/ (508) 12 exp hydrocolloid dressing/ (628) 13 exp silver/ (27276) 14 exp sulfadiazine silver/ (3015) 15 exp sulfathiazole silver/ (19) 16 exp polyurethan/ (9963) 17 exp iodine/ (36182) 18 exp chlorhexidine/ (12160) 19 ((occlusive* or hydrocolloid* or silver* or polyurethane* or permeable or nonpermeable or non‐permeable or transparent or chlorhexidine or iodine* or gauze or tape) adj3 (dressing* or sponge*)).tw. (3408) 20 or/11‐19 (89926) 21 10 and 20 (1216) 22 Randomized controlled trials/ (57946) 23 Single‐Blind Method/ (18790) 24 Double‐Blind Method/ (117793) 25 Crossover Procedure/ (40165) 26 (random$ or factorial$ or crossover$ or cross over$ or cross‐over$ or placebo$ or assign$ or allocat$ or volunteer$).ti,ab. (1366645) 27 (doubl$ adj blind$).ti,ab. (149833) 28 (singl$ adj blind$).ti,ab. (14881) 29 or/22‐28 (1437406) 30 exp animals/ or exp invertebrate/ or animal experiment/ or animal model/ or animal tissue/ or animal cell/ or nonhuman/ (20630118) 31 human/ or human cell/ (15052414) 32 and/30‐31 (15005735) 33 30 not 32 (5624383) 34 29 not 33 (1242391) 35 21 and 34 (220) 36 2014*.em. (1159417) 37 35 and 36 (14)
EBSCO CINAHL
S38S25 AND S37 S37S26 or S27 or S28 or S29 or S30 or S31 or S32 or S33 or S34 or S35 or S36 S36TX allocat* random* S35(MH "Quantitative Studies") S34(MH "Placebos") S33TX placebo* S32TX random* allocat* S31(MH "Random Assignment") S30TX randomi* control* trial* S29TX ( (singl* n1 blind*) or (singl* n1 mask*) ) or TX ( (doubl* n1 blind*) or (doubl* n1 mask*) ) or TX ( (tripl* n1 blind*) or (tripl* n1 mask*) ) or TX ( (trebl* n1 blind*) or (trebl* n1 mask*) ) S28TX clinic* n1 trial* S27PT Clinical trial S26(MH "Clinical Trials+") S25S11 and S24 S24S12 or S13 or S14 or S15 or S16 or S17 or S18 or S19 or S20 or S21 or S22 or S23 S23TI ( occlusive* N3 sponge* or hydrocolloid* N3 sponge* or silver* N3 sponge* or polyurethane* N3 sponge* or permeable N3 sponge* or nonpermeable N3 sponge* or non‐permeable N3 sponge* or transparent N3 sponge* or chlorhexidine N3 sponge* or iodine* N3 sponge* or gauze N3 sponge* or tape N3 sponge* N3 sponge* ) OR AB ( occlusive* N3 sponge* or hydrocolloid* N3 sponge* or silver* N3 sponge* or polyurethane* N3 sponge* or permeable N3 sponge* or nonpermeable N3 sponge* or non‐permeable N3 sponge* or transparent N3 sponge* or chlorhexidine N3 sponge* or iodine* N3 sponge* or gauze N3 sponge* or tape N3 sponge* N3 sponge* ) S22TI ( occlusive* N3 dressing* or hydrocolloid* N3 dressing* or silver* N3 dressing* or polyurethane* N3 dressing* or permeable N3 dressing* or nonpermeable N3 dressing* or non‐permeable N3 dressing* or transparent N3 dressing* or chlorhexidine N3 dressing* or iodine* N3 dressing* or gauze N3 dressing* or tape N3 dressing*) OR AB (occlusive* N3 dressing* or hydrocolloid* N3 dressing* or silver* N3 dressing* or polyurethane* N3 dressing* or permeable N3 dressing* or nonpermeable N3 dressing* or non‐permeable N3 dressing* or transparent N3 dressing* or chlorhexidine N3 dressing* or iodine* N3 dressing* or gauze N3 dressing* or tape N3 dressing*) S21(MH "Chlorhexidine") S20(MH "Iodine") S19(MH "Transparent Dressings") S18(MH "Polyurethanes") S17(MH "Gauze Dressings") S16(MH "Ionic Silver Dressings") S15(MH "Silver Sulfadiazine") S14(MH "Silver") S13(MH "Hydrocolloid Dressings") S12(MH "Occlusive Dressings") S11S1 or S2 or S3 or S4 or S5 or S6 or S7 or S8 or S9 or S10 S10TI ( hemodialysis catheter* or haemodialysis catheter* ) OR AB ( hemodialysis catheter* or haemodialysis catheter* ) S9TI ( peripherally inserted central catheter or PICC ) OR AB ( peripherally inserted central catheter or PICC ) S8TI ( implantable vascular access device or IAVD or PortACath ) OR AB ( implantable vascular access device or IAVD or PortACath ) S7(MH "Vascular Access Devices, Implantable") S6TI cook catheter* OR AB cook catheter* S5TI broviac catheter* OR AB broviac catheter* S4TI hickman catheter* OR AB hickman catheter* S3TI ( central N3 (catheter* or line*) ) OR AB ( central N3 (catheter* or line*) ) S2TI ( venous N3 (catheter* or line*) ) OR AB ( venous N3 (catheter* or line*) ) S1(MH "Central Venous Catheters+")
Data and analyses
Comparison 1. Primary analysis.
| Outcome or subgroup title | No. of studies | No. of participants | Statistical method | Effect size |
|---|---|---|---|---|
| 1 Catheter‐related blood stream infection | 14 | Risk Ratio (M‐H, Random, 95% CI) | Subtotals only | |
| 1.1 Gauze and tape versus SPU | 8 | 506 | Risk Ratio (M‐H, Random, 95% CI) | 0.64 [0.26, 1.63] |
| 1.2 CGI versus SPU | 5 | 4876 | Risk Ratio (M‐H, Random, 95% CI) | 0.65 [0.40, 1.05] |
| 1.3 Medication‐impregnated dressings versus all others | 6 | 5687 | Risk Ratio (M‐H, Random, 95% CI) | 0.60 [0.39, 0.93] |
| 2 Frequency of catheter‐related BSI per 1000 patient days | 6 | Rate Ratio (Random, 95% CI) | Subtotals only | |
| 2.1 Gauze and tape versus SPU | 2 | Rate Ratio (Random, 95% CI) | 0.71 [0.20, 2.52] | |
| 2.2 CGI versus SPU | 4 | Rate Ratio (Random, 95% CI) | 0.51 [0.33, 0.78] | |
| 3 Catheter tip colonisation | 11 | Risk Ratio (M‐H, Random, 95% CI) | Subtotals only | |
| 3.1 Gauze and tape versus SPU | 5 | 342 | Risk Ratio (M‐H, Random, 95% CI) | 0.95 [0.51, 1.77] |
| 3.2 CGI versus SPU | 6 | 4431 | Risk Ratio (M‐H, Random, 95% CI) | 0.58 [0.47, 0.73] |
| 4 Entry‐ and exit‐site infection | 2 | Risk Ratio (M‐H, Random, 95% CI) | Subtotals only | |
| 4.1 Gauze and tape versus SPU | 2 | 199 | Risk Ratio (M‐H, Random, 95% CI) | 0.84 [0.34, 2.07] |
| 5 Skin/site colonisation | 2 | Risk Ratio (M‐H, Random, 95% CI) | Subtotals only | |
| 5.1 Gauze and tape versus SPU | 2 | 170 | Risk Ratio (M‐H, Random, 95% CI) | 0.86 [0.30, 2.51] |
| 6 Skin irritation or damage | 2 | Risk Ratio (M‐H, Random, 95% CI) | Subtotals only | |
| 6.1 CGI versus SPU | 2 | 850 | Risk Ratio (M‐H, Random, 95% CI) | 11.17 [0.84, 149.48] |
| 7 Failed catheter securement | 2 | Risk Ratio (M‐H, Random, 95% CI) | Subtotals only | |
| 7.1 Gauze and tape versus SPU | 2 | 167 | Risk Ratio (M‐H, Random, 95% CI) | 0.90 [0.33, 2.49] |
Comparison 2. Sensitivity analysis: studies at low risk of bias.
| Outcome or subgroup title | No. of studies | No. of participants | Statistical method | Effect size |
|---|---|---|---|---|
| 1 Catheter tip colonisation | 4 | 4253 | Risk Ratio (M‐H, Random, 95% CI) | 0.59 [0.46, 0.77] |
Characteristics of studies
Characteristics of included studies [ordered by study ID]
Arvaniti 2012.
| Methods | RCT in 5 ICUs in Greece | |
| Participants | 306 participants admitted to ICUs requiring a multilumen CVC Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU changed every 3 days or sooner if spoiled or contaminated Group II: SPU and a chlorhexidine‐impregnated sponge (BiopatchTM) changed every 7 days Both groups had sterile gauze over the entry site for the first 24 hours |
|
| Outcomes |
|
|
| Notes | Group III: Additional 159 participants not included in the review: silver‐impregnated CVC (OligonTM) due to co‐intervention. | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Quotation: "patients were randomly allocated to one of the three groups, separately for each participating ICU, and according to computer‐generated randomization sequences" (p 421) |
| Allocation concealment (selection bias) | Unclear risk | Quotation: "The randomization number and the corresponding study group were sealed in envelopes in numeric order. Envelopes were posted to the ICUs with accompanying instructions to be opened by respecting their numerical order" (p 421) Not stated if envelopes were opaque |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Quotation: "Double‐blind design was not possible as a result of apparent differences between the compared products" (p 421) |
| Blinding of outcome assessment (detection bias) All outcomes | Low risk | Quotation: "Two ICU infectious diseases experts scrutinized all data blinded to the randomization group to identify concomitant infections and avoid erroneous attribution of the recorded events to the study catheters" (p 422) |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | Well described attrition data; loss to follow up for catheter tip colonisation outcome 19.1% (figure 1; p 422) Intention‐to‐treat analysis undertaken. Quotation: "data were also analyzed as per protocol analysis in which all uncultured catheters were considered missing" (p 422) |
| Selective reporting (reporting bias) | Unclear risk | No clinical trial registration or published protocol All outcomes reported as described in publication |
| Other bias | Unclear risk | Significant difference between groups for patient age (p 423) |
Brandt 1996.
| Methods | RCTl in the USA | |
| Participants | 101 participants undergoing autologous BMT with newly inserted long‐term triple‐lumen, tunnelled HickmanTM CVCs Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU (Opsite 3000TM; Smith and Nephew) moisture vapour permeable dressing changed every 7 days Group II: sterile gauze with tape changed daily |
|
| Outcomes |
|
|
| Notes | Dressing condition/durability reported: did not use a tool with established validity and reliability | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "subjects were randomly assigned" (p 830) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | No loss to follow‐up reported. Less than 10% attrition. Not stated whether intention‐to‐treat analysis was used |
| Selective reporting (reporting bias) | Unclear risk | No clinical trial registration or published protocol |
| Other bias | Unclear risk | Baseline balance of groups: no statistically significant differences (p 832) |
Carrer 2005.
| Methods | Randomised, factorial controlled trial in a single Italian ICU | |
| Participants | 82 participants admitted to a medical‐surgical ICU Inclusion criteria:
Exclusion criteria: not reported |
|
| Interventions | Group I: gauze and tape with low sterile barrier Group II: transparent simple polyurethane (SPU) with low sterile barrier Group III: gauze and tape with maximum sterile barrier Group IV: SPU with maximum sterile barrier For the purposes of the review: Groups I and III (gauze) were combined and Groups II and IV (SPU) were combined |
|
| Outcomes | Skin/site colonisation | |
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Not reported Quotation: "patients were randomly subdivided in four groups" (p 198) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | High risk | Large attrition rate in some groups, which are not accounted for in analysis. Intention‐to‐treat analysis not used |
| Selective reporting (reporting bias) | High risk | Catheter‐related BSI: information collected, but not presented by intervention group |
| Other bias | Unclear risk | Baseline balance of groups: Quotation: "Groups were homogenous" (p 199) Multiple CVCs per participant recruited, analysis per CVC |
Chambers 2005.
| Methods | RCT in a single site in New Zealand | |
| Participants | 95 participants admitted to a haematology unit Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: no dressing Group II: CGI dressings consisting of a 2.5 cm hydrophilic polyurethane foam disk containing chlorhexidine gluconate in a sustained‐release formulation, with a SPU (Opsite IV3000TM), changed weekly or as needed until catheter removal Both groups had sterile gauze and SPU applied until the exit site was dry and free from exudate |
|
| Outcomes |
|
|
| Notes | Patients recruited more than once: CVC unit of analysis | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Not reported |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Quotation: "the clinical team was not blinded to treatment" (p 59) |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported Quotation: "all cases of infection were initially classified by three investigators (STC, RLS and JS) and were later reviewed independently by another investigator (PG)" (p 56) |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Well described attrition data: complete data were not available on 2 participants, 1 from each group, who left the hospital and continued treatment elsewhere (p 57). Intention‐to‐treat analysis described |
| Selective reporting (reporting bias) | High risk | No clinical trial registration or published protocol Catheter tip colonisation not fully described per study group |
| Other bias | Unclear risk | Minimal information of patient characteristics described, not clear whether groups balanced at baseline |
Conly 1989.
| Methods | RCT in a single site in Canada | |
| Participants | 79 participants admitted to medical, surgical, paediatric or ICU Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: dry gauze and tape Group II: SPU (OpsiteTM) A pressure dressing was allowed for the first 24‐48 hours for both groups |
|
| Outcomes |
|
|
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | High risk | Quotation: "were prospectively randomized"; "patients were randomly assigned by hospital number" (p 310) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | High risk | Large amounts of attrition and missing data not adequately described by the manuscript; including outcome data |
| Selective reporting (reporting bias) | High risk | No clinical trial registration or published protocol Skin/site colonisation not described by study group ‐ outcome could not be included in the review |
| Other bias | High risk | Groups not balanced at baseline including higher ICU admission, steroid usage and jugular vein insertion in the gauze group. This may have resulted in a higher risk of catheter‐related BSI and catheter tip colonisation in this group Patients recruited once, but multiple CVCs included. CVC unit of analysis |
de Barros 2009.
| Methods | RCT in Spain | |
| Participants | 66 participants with long‐term CVCs for haemodialysis Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU (TegadermTM; 3M) changed every 7 days or as needed Group II: sterile gauze with tape changed at each dialysis session |
|
| Outcomes |
|
|
| Notes | One CVC per participant only | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "a random list of dressings was used to divide 66 patients in two groups (33 in group 1 and 33 in group 2" (p 482) |
| Allocation concealment (selection bias) | Unclear risk | Quotation: "the sequences of dressings were kept in a locked envelope. If the patient was eligible... the envelope containing dressing sequences was opened and the following indicated intervention was performed" (p 482) Not reported whether the envelope was opaque |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Low risk | Quotation: "the microbiologists processed the samples without knowing how patients were allocated in the study" (p 483) |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | No loss to follow‐up reported. Not stated whether intention‐to‐treat analysis was used |
| Selective reporting (reporting bias) | Unclear risk | No clinical trial registration or published protocol |
| Other bias | Unclear risk | Baseline balance of groups: no statistically significant differences (p 484) |
Garland 2001.
| Methods | RCT in 6 neonatal ICUs in the USA | |
| Participants | 705 participants admitted to a neonatal ICUs Inclusion criteria:
Exclusion criteria: not clearly reported. Changed after 15 months of study recruitment related to adverse reactions; infants < 26 weeks who required a CVC before 1 week of age were excluded |
|
| Interventions | Group I: SPU cleansed with 10% povidone iodine. Percutaneous CVC dressings were changed every 7 days, surgically inserted CVC dressings were changed twice weekly Group II: CGI dressing (BiopatchTM) with 250 µg/mg of chlorhexidine gluconate and SPU. Cleansed with 70% isopropyl. Both percutaneous and surgically inserted CVC dressings were changed weekly |
|
| Outcomes |
|
|
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Quotation: "neonates were block randomized" (p 1431) Quotation: "computer generated randomization codes developed by the study statistician were maintained by center pharmacists" (p 1432) |
| Allocation concealment (selection bias) | Low risk | Quotation: "maintained by the pharmacy at hospital" (p 1432) |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not stated |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not stated |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Similar attrition rates for loss to follow‐up in both groups; microbial analysis of catheter colonisation not performed 8% of SPU group, 6% of CGI group |
| Selective reporting (reporting bias) | Unclear risk | Not registered as a clinical trial, no published protocol Reported all outcomes described in publication |
| Other bias | Unclear risk | Baseline balance of groups: no statistically significant differences (table 1) Confounding differences in interventions: 10% povidone‐iodine for skin antisepsis in Group I; 70% isopropyl for skin antisepsis in Group II. Funded by product company (Johnson and JohnsonTM) who manufacture the products used in both intervention and control arms |
Giles 2002.
| Methods | RCT in a general surgery department in Turkey | |
| Participants | 72 participants with single‐lumen polyurethane CVCs inserted pre‐operatively Inclusion criteria: not clearly outlined Quotation: "patients undergoing surgical procedures for various benign or malignant gastrointestinal disorders" (p 256) Quotation: "the aims of CVC insertion were either for monitoring or TPN administration" (p 256) Exclusion criteria: not reported |
|
| Interventions | Group I: transparent occlusive dressing changed every 7 days unless signs of local inflammation Group II: sterile gauze changed daily and insertion site cleaned by 10% povidone‐iodine solution |
|
| Outcomes |
|
|
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Not reported Quotation: "according to the number patient on the random table" (p 256) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | No missing data. No loss to follow‐up |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol. All reported outcomes described |
| Other bias | Unclear risk | Groups are balanced at baseline; no statistically significant difference between groups |
Hagerstrom 1994.
| Methods | RCT in Sweden in 2 dialysis units | |
| Participants | 14 participants with long‐term CVCs for haemodialysis Inclusion criteria:
Exclusion criteria: not reported |
|
| Interventions | Group I: SPU (OpSite IV3000TM ) changed after haemodialysis procedure (approximately twice/week) Group II: sterile gauze with tape changed after haemodialysis procedure (approximately twice/week) |
|
| Outcomes | Catheter‐related BSI | |
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "were randomised to one of the two dressing treatment groups" (study design section) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Attrition and loss to follow‐up were not reported |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol. All reported outcomes described |
| Other bias | Unclear risk | No description of baseline participant comparison |
Hill 2010.
| Methods | RCT in a neonatal ICU in the USA | |
| Participants | 100 participants admitted to a neonatal ICU Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU (TegadermTM; 3M). Dressings changed every 3 weeks, unless otherwise indicated Group II: silver‐impregnated dressing (Algidex Ag IV PATCHTM) secured with a steri strip. The patch, extraluminal catheter and exit site were then covered with a SPU dressing (TegadermTM; 3MM). Dressings changed every 2 weeks, unless otherwise indicated |
|
| Outcomes |
|
|
| Notes | Catheter‐related BSI was a secondary outcome of study, but was not defined | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "computer randomization" (p 471) |
| Allocation concealment (selection bias) | Unclear risk | Quotation: "envelopes containing the status were assembled unknown to the principal investigator and study nurse. After each patient was enrolled, the envelope with the number corresponding to order of enrolment was opened and the patient was placed in their assigned group" (p 470) Not stated if the envelopes were opaque |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Not blinded. Quotation: "To assess skin safety, the bedside nurse evaluated the skin under the transparent dressing at least twice daily and documented any signs of redness, swelling or discoloration" (p 471) |
| Blinding of outcome assessment (detection bias) All outcomes | High risk | Not blinded. Quotation: "To assess skin safety, the bedside nurse evaluated the skin under the transparent dressing at least twice daily and documented any signs of redness, swelling or discoloration" (p 471) |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | Outcome data adequately described. No reported loss to follow‐up |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol. All reported outcomes described |
| Other bias | High risk | Baseline imbalances on several variables including gender, age and birthweight |
le Corre 2003.
| Methods | RCT in Canada | |
| Participants | 58 participants with long‐term CVCs for haemodialysis Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU (TegadermTM; 3M) changed every 7 days Group II: sterile gauze with tape changed every 2‐3 days |
|
| Outcomes | Catheter‐related BSI | |
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Quotation: "computer generated 1:1 ratio" (p 57) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Quotation: "open‐label" (p 57) |
| Blinding of outcome assessment (detection bias) All outcomes | High risk | Quotation: "open‐label" (p 57) |
| Incomplete outcome data (attrition bias) All outcomes | High risk | Large amount of attrition. Only 58/62 were included in final analysis; intention‐to‐treat not used. 17 not followed up to removal at 6 months |
| Selective reporting (reporting bias) | Unclear risk | Not registered as a clinical trial, no published protocol |
| Other bias | Unclear risk | Baseline balance of groups: no statistically significant differences (table 1) |
Levy 2005.
| Methods | RCT in a single paediatric cardiac ICU in Israel | |
| Participants | 145 participants admitted to the paediatric cardiac ICU Inclusion criteria:
Exclusion criteria: not reported |
|
| Interventions | Group I: SPU (TegadermTM; 3M) only changed when required (e.g. mechanical complication, bleeding, oozing, signs of exit‐site infection) Group II: CGI (BiopatchTM) and SPU only changed when required (e.g. mechanical complication, bleeding, oozing, signs of exit‐site infection) |
|
| Outcomes |
|
|
| Notes | Catheter‐related BSI: data collected as a secondary outcome, but study definition did not match review definition | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Quotation: "Random number generator" (p 677) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Not blinded. Quotation: "The CVC insertion site was inspected daily by the nursing staff and by the study investigators (O.D.) for adverse events" (p 677) |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Quotation: "the microbiology laboratory personnel were blinded and could not identify which group the CVC had been randomized" (p 677) Skin irritation outcome assessor not blinded |
| Incomplete outcome data (attrition bias) All outcomes | High risk | Significant attrition and loss to follow‐up. Post‐randomization attrition information not provided by group |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol Exit‐site infection rates were not reported in results section |
| Other bias | Unclear risk | Baseline balance of groups: no statistically significant differences (p 678) |
Nikoletti 1999.
| Methods | RCT in an adult ICU in Australia | |
| Participants | 150 participants with CVCs inserted in ICU Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU (TegadermTM; 3M) changed every 5 days or earlier if soiled or nonadherent Group II: hydrocolloid dressing (ComfeelTM) changed every 5 days or earlier if soiled or nonadherent |
|
| Outcomes | Catheter‐tip colonisation | |
| Notes | Catheter‐related BSI and skin colonisation outcomes were described, but did not meet the review's outcome definition | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Not described in publication Correspondence with authors: "computer generated random numbers" |
| Allocation concealment (selection bias) | Unclear risk | Not reported in publication or correspondence with authors |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Not described in publication Correspondence with authors: "participants and clinicians were not blinded" |
| Blinding of outcome assessment (detection bias) All outcomes | Low risk | Not described in publication Correspondence with authors: "blinded microbiological outcome assessment" |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Large amounts of missing data and attrition. The majority was well described in the publication |
| Selective reporting (reporting bias) | Unclear risk | Protocol well described, but not published. Not registered as a clinical trial |
| Other bias | Low risk | Baseline balance of groups: no statistically or clinically significant differences in age, critical illness severity, length of hospital stay (Table 2, p 491) |
Olson 2004.
| Methods | RCT in an inpatient and outpatient oncology setting in Canada | |
| Participants | 78 participants undergoing treatment for cancer Inclusion criteria:
Exclusion criteria:not stated |
|
| Interventions | Group I: sterile gauze dressing, changed daily if neutropenic or every second day if not neutropenic; cleansed with 4% chlorhexidine in 70% alcohol Group II: no dressing Both groups were treated as if in Group I until day 21 post CVC insertion, when they were randomised |
|
| Outcomes | Catheter‐related BSI | |
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Not stated in publication Private correspondence with authors: "computer generated sequence" |
| Allocation concealment (selection bias) | Unclear risk | Not stated in publication Private correspondence with authors: "envelopes", not stated if opaque |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Participants and family members cared for the CVC dressing and securement regimen throughout the study (p 38) |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not stated |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | No attrition or loss‐to‐follow up data provided |
| Selective reporting (reporting bias) | High risk | Outcomes of catheter‐tip colonisation and skin/site colonisation were not reported No clinical trial registration or published protocol |
| Other bias | Unclear risk | Trial stopped recruitment early for unknown reasons |
Pedrolo 2011.
| Methods | RCT in Brazil | |
| Participants | 21 participants admitted to ICU Inclusion criteria:
Exclusion criteria: not reported |
|
| Interventions | Group I: SPU (TegadermTM; 3M) changed every 7 days or when exudate or displacement made it necessary Group II: sterile gauze with tape changed daily |
|
| Outcomes |
|
|
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "a drawing was performed to allocate individuals in the control or study groups" (p 279) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | Quotation: "all catheters were observed until removed and there was no loss to follow up" (p 280) |
| Selective reporting (reporting bias) | Unclear risk | Not registered as a clinical trial, no published protocol |
| Other bias | Unclear risk | No description of participant population for baseline variability; catheter data only |
Roberts 1998.
| Methods | RCT in a single ICU in Australia | |
| Participants | 33 participants admitted to ICU Inclusion criteria:
Exclusion criteria: not reported Participants could be recruited more than once. Unit of analysis was the CVC not the participant |
|
| Interventions | Group I: SPU (Opsite IV3000TM ), changed and cleansed with 0.5% chlorhexidine in 70% alcohol every 5 days and as necessary Group II: CGI dressing (BiopatchTM) with SPU (Opsite IV3000TM ), changed and cleansed with 0.5% chlorhexidine in 70% alcohol every 5 days and as necessary |
|
| Outcomes |
|
|
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "Randomly assigned to either the experimental or the control group" |
| Allocation concealment (selection bias) | Unclear risk | Not stated |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not stated |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not stated |
| Incomplete outcome data (attrition bias) All outcomes | High risk | Missing data on 7/40 participants, attrition not well described |
| Selective reporting (reporting bias) | High risk | Did not report catheter‐related infection outcomes No registration of clinical trial or published protocol |
| Other bias | Unclear risk | Baseline balance of groups: no statistically or clinically significant differences in age, gender, CVC duration. Other clinical variables (e.g. critical illness severity) not stated (p 17) |
Ruschulte 2009.
| Methods | RCT in Germany | |
| Participants | 601 participants with haematological and oncological conditions Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU changed regularly after 7 days or if they had been lifted Group II: CGI dressing (BiopatchTM) with SPU. Changed regularly after 7 days or if they had been lifted |
|
| Outcomes | Catheter‐related BSI | |
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Not stated |
| Allocation concealment (selection bias) | Unclear risk | Not stated |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Personnel and participants were not blinded. Quotation: "The insertion sites were inspected and palpated daily by the specialist oncology nurses" (p 268) |
| Blinding of outcome assessment (detection bias) All outcomes | Low risk | Quote: "by having nurses who were not involved in the study assess the insertion sites and microbiologists unaware of the patients' group assignments" (p 271) |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | No attrition or loss to follow‐up |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol |
| Other bias | Unclear risk | Baseline balance of groups: no statistically or clinically significant differences in age, gender, neutropenia, CVC duration (table 1, p 269) |
Shivnan 1991.
| Methods | RCT in the USA | |
| Participants | 98 participants undergoing autologous or allogenic BMT with pre‐existing or newly inserted right atrial CVCs Inclusion criteria:
Exclusion criteria: not described |
|
| Interventions | Group I: SPU (TegadermTM 3M) changed every 4 days Group II: sterile gauze with tape changed daily Both groups received gauze for the first 24 hours |
|
| Outcomes |
|
|
| Notes | Many skin colonisation dates reported; short term (day 8) colonisation reported within the review. | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Quotation: "block randomisation within each stratum" (p 1350) |
| Allocation concealment (selection bias) | Unclear risk | Not reported |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not reported |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not reported |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | 5/103 excluded post‐randomisation 27.5% required modifications of the dressing Not stated whether intention‐to‐treat analysis was used |
| Selective reporting (reporting bias) | Unclear risk | No clinical trial registration or published protocol Main study aims were assessed and reported |
| Other bias | Unclear risk | Baseline balance of groups: no statistically significant differences (p 1352) Sponsored by product manufacturer (3M CompanyTM, St. Paul, MN) manufacturer of the SPU intervention No data on topical vancomycin use and dressing modification for each group |
Timsit 2009.
| Methods | RCT in France | |
| Participants | 2051 participants in ICUs Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU dressing (TegadermTM; 3M) changed every 3 or 7 days Group II: CGI sponge dressing (BioPatchTM; Ethicon Inc) with SPU changed every 3 or 7 days |
|
| Outcomes |
|
|
| Notes | Published manuscript includes arterial lines; additional information provided to report CVC‐only results | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Quotation: “The randomization schedule, stratified by ICU, was developed using a web‐based random‐number generator to select permuted blocks of 8 patients each” (p 1232) |
| Allocation concealment (selection bias) | Unclear risk | Not described |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Quotation: “The study was not blinded for the investigators or ICU staff” (p 1232) Not described for participants |
| Blinding of outcome assessment (detection bias) All outcomes | Low risk | Quote: “Was blinded for the microbiologists processing the skin and catheter cultures and for the assessors” (p 1232) |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | Moderate attrition, well described in CONSORT diagram (Figure 1; p 1235) |
| Selective reporting (reporting bias) | Unclear risk | Difficult to obtain separated CVC outcomes, not originally reported Clinical trial registered via clinicaltrials.gov |
| Other bias | Unclear risk | Baseline variables not reported for CVC outcomes. Balanced critical illness severity, length of ICU stay, mechanical ventilation, age for overall study as per Table 1 (p 1236) |
Timsit 2012.
| Methods | RCT in France | |
| Participants | 1879 participants in ICUs Inclusion criteria:
Exclusion criteria:
|
|
| Interventions | Group I: SPU dressing (TegadermTM; 3M) Group II: CGI dressing (Tegaderm CHG IV Securement DressingTM; 3M) Group III: highly adhesive transparent dressing (Tegaderm HP TransparentTM; 3M) |
|
| Outcomes |
|
|
| Notes | Published manuscript includes arterial lines; additional information provided to report CVC‐only results | |
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Quotation: “Randomization was by a web‐based random‐number generator producing permuted blocks of eight, with stratification on ICUs. Each block contained four allocations to the chlorhexidine dressing, two to the highly adhesive dressing and two to the standard dressing. The investigators were unaware of the block size and of the permutation procedure” (p 1273) |
| Allocation concealment (selection bias) | Unclear risk | Not described |
| Blinding of participants and personnel (performance bias) All outcomes | High risk | Quotation: “The study was not blinded for the investigators or ICU staff” (p 1273) Not described for participants |
| Blinding of outcome assessment (detection bias) All outcomes | Low risk | Quotation: “was blinded for the microbiologists processing the skin and catheter cultures and for the adjudication committee” (p 1273) |
| Incomplete outcome data (attrition bias) All outcomes | Low risk | Moderate attrition, well described in CONSORT diagram (Figure 1; p 1275) Quotation: “Analyses were performed in the intent‐to‐treat population, which included all patients except those who withdrew their consent to study participation.” (p 1274) |
| Selective reporting (reporting bias) | Unclear risk | Difficult to obtain separated CVC outcomes, not originally reported Clinical trial registered via clinicaltrials.gov |
| Other bias | Unclear risk | Baseline variables not reported for CVC outcomes – balanced for overall study Supported by 3M (St Paul, MN); the manufacturer of all of the study interventional products |
Wille 1993.
| Methods | RCT in the Netherlands | |
| Participants | 101 adult participants requiring a subclavian or jugular CVC Inclusion criteria:
Exclusion criteria: not stated |
|
| Interventions | Group I: SPU (OpSiteTM; Smith and Nephew) with moisture vapour permeability of 800 g m‐². Changed regularly every 3 days. Group II: new generation SPU (OpSite IV3000TM; Smith and Nephew) with increased moisture vapour permeability (2000 g m‐²). Dressing changed every 3 days |
|
| Outcomes | Catheter‐related BSI | |
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Unclear risk | Not described Quotation: "the patients were randomized to one of the two dressing groups" (p 114) |
| Allocation concealment (selection bias) | Unclear risk | Not described |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not described |
| Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not described |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Attrition poorly described. No information on missing data Quotation: "the 13 patients not included in the analysis were evenly distributed between the two dressing groups" (p 115) |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol. All outcomes described in publication |
| Other bias | Unclear risk | No data on co morbidities or severity of illness Sponsored by Smith & NephewTM, Harlow, UK ‐ product manufacturer of both intervention groups |
Yamamoto 2002.
| Methods | RCT in the USA | |
| Participants | 170 adult participants requiring a peripherally inserted central catheter (PICC) Inclusion criteria: not stated Exclusion criteria: not stated |
|
| Interventions | Group I: securement via 2.0 prolene sutures and standard polyurethane dressing (SPU). Changed regularly every 3 days or more frequently if necessary Group II: securement via a SSD (StatLockTM) and SPU. Dressing changed every 3 days, SSD every 6 days When participant discharged home, dressings changed weekly |
|
| Outcomes |
|
|
| Notes | ||
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Random sequence generation (selection bias) | Low risk | Not stated in publication Private correspondence: "using blinded envelopes" |
| Allocation concealment (selection bias) | Low risk | Quotation: "concealed envelopes distributed to research assistants" (p 78) |
| Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not stated |
| Blinding of outcome assessment (detection bias) All outcomes | High risk | Outcome assessors for dislodgement and skin damage not blinded Not stated whether microbiology outcome assessors were blinded |
| Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Loss to follow‐up and attrition not stated |
| Selective reporting (reporting bias) | Unclear risk | No registration of clinical trial or published protocol |
| Other bias | Unclear risk | Research sponsored by StatLock product manufacturer (Venetec International, San Diego, CA) |
Abbreviations
BMT: bone marrow transplant CGI: chlorhexidine‐impregnated CVC: central venous catheter ICU: intensive care unit PICC: peripherally‐inserted central catheter RCT: randomised controlled trial SPU: standard polyurethane SSD: sutureless securement device TPN: total parenteral nutrition
Characteristics of excluded studies [ordered by study ID]
| Study | Reason for exclusion |
|---|---|
| Crawford 2004 | No outcomes that accorded with our review definitions: cost‐related data only |
| Davidson 1986 | No outcomes reported that accorded with our review definitions: no definitions of blood and skin cultures provided |
| Freiberger 1992 | Results not reported by intervention group Skin/site swab with any bacterial growth included: not positive semi‐quantitative (> 15 cfu) or quantitative (> 10³ cfu) culture from the skin around the catheter site (O'Grady 2002) |
| George 2011 | No outcomes reported that accorded with our review definitions: no definition or assessment tool to evaluate skin irritation or damage |
| Keenlyside 1991 | No outcomes reported that accorded with our review definitions: no definition or assessment tool to evaluate dressing condition, skin irritation or damage |
| Keenlyside 1993 | Duplicate publication from Keenlyside 1991: no outcomes that accorded with our review definitions |
| Khattak 2010 | No outcomes that accorded with our review definitions: all blood cultures included, not catheter‐related BSI |
| Lawson 1986 | No outcomes that accorded with our review definitions: no definition or assessment tool to evaluate skin irritation, damage or infection |
| Little 1998 | Inadequate data for extraction |
| Lucas 1996 | No outcomes that accorded with our review definitions: no definition regarding microbiological criteria for skin/site colonisation |
| Madeo 1998 | Arterial and CVC outcomes reported together; unable to extract CVC outcomes |
| Maki 1984 | Not a RCT |
| Maki 2000 | Arterial and CVC outcomes reported together; unable to extract CVC outcomes |
| Neufeld 1991 | No outcomes that accorded with our review definitions: no definition regarding microbiological criteria for skin/site colonisation |
| Olson 2008 | No outcomes as per our review definitions: outcome assessments used to describe skin irritation or damage did not have established reliability |
| Petrosino 1988 | No outcomes that accorded with our review definitions: described skin/site colonisation without microbiological definition |
| Powell 1982 | No outcomes that accorded with our review definitions. Catheter‐related BSI not in accordance with review outcome definitions |
| Powell 1985 | Extreme confounders involving the use of specific dosages of skin antisepsis and administration set change intervals within the interventions |
| Reynolds 1997 | CCT not RCT (sequential assignment) |
| Schwebel 2012 | No outcomes as per our review definitions: cost‐related data only |
| Timsit 2010 | No outcomes as per our review definitions: cost‐related data only |
Characteristics of studies awaiting assessment [ordered by study ID]
Broadhurst 2014.
| Methods | |
| Participants | |
| Interventions | |
| Outcomes | |
| Notes | authors contacted for further information |
Calvino 2014.
| Methods | |
| Participants | |
| Interventions | |
| Outcomes | |
| Notes | authors contacted for further information |
Gu 2014.
| Methods | |
| Participants | |
| Interventions | |
| Outcomes | |
| Notes | authors contacted for further information |
Pedrolo 2014.
| Methods | |
| Participants | |
| Interventions | |
| Outcomes | |
| Notes | authors contacted for further information |
Differences between protocol and review
Our protocol planned to calculate hazard ratios (HR) to estimate the effect of interventions for time‐to‐event data. HR can only be calculated from full data sets, log‐rank results, KaplanMeier curves or Cox results. Instead we have calculated Incidence Rate Ratio, which is also appropriate for time‐to‐event data as it considers the at‐risk periods (Deeks 2011; Parmar 1998).
Contributions of authors
Amanda Ullman: conceived, designed and coordinated the review. Extracted data and checked quality of data extraction. Undertook and checked quality assessment. Analysed and interpreted data. Performed statistical analysis and checked quality of statistical analysis. Wrote and edited the review. Advised on the review and approved the final review prior to submission. Wrote to study authors/experts/companies. Is the guarantor of the review. Marie Cooke: conceived the review. Extracted data and undertook quality assessment. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission. Marion Mitchell: conceived the review. Extracted data and undertook quality assessment. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission. Frances Lin: conceived the review. Extracted data and undertook quality assessment. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission. Karen New: conceived the review. Extracted data and undertook quality assessment. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission. Wrote to study authors/experts/companies. Debbie Long: conceived the review. Extracted data and undertook quality assessment. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission. Wrote to study authors/experts/companies. Gabor Mihala: conceived the review. Extracted data and analysed and interpreted data. Performed statistical analysis and checked quality of statistical analysis. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission. Claire Rickard: conceived the review. Extracted data and undertook quality assessment. Performed part of writing and editing the review, advised on the review and made an intellectual contribution to the review. Approved the final review prior to submission.
Contributions of editorial base:
Nicky Cullum: edited the review, advised on methodology, interpretation and review content. Approved the final review prior to submission. Sally Bell‐Syer: coordinated the editorial process. Advised on methodology, interpretation and content. Edited the review. Ruth Foxlee: designed the search strategy and edited the search methods section.
Sources of support
Internal sources
No sources of support supplied
External sources
NIHR/Department of Health (England), (Cochrane Wounds Group), UK.
Declarations of interest
Griffith University received an unrestricted educational grant from 3M (a manufacturer of CVC dressings and securement devices) to assist with the costs of Claire Rickard's (CR) research nurses' travel to a conference in 2014. Griffith University received a consultancy payment from 3M in 2013 for CR to present an educational lecture based on her independent research. Griffith University received an unrestricted investigator initiated research grant from 3M in 2014 to support a research study on which CR is an investigator, but this study was unrelated to CVC dressings and securement. Studies involving 3M's CVC dressings (Tegaderm range) are included in this review but the conclusions do not recommend these over competitor products. Griffith University received an unrestricted investigator‐initiated research grant from Centurion Medical (manufacturer of CVC dressings) as part‐funding for the CASCADE Pilot Trial led by CR, and for a PhD student scholarship Top Up for Amanda J Ullman. No trials investigating Centurion Medical's dressings were included in this review.
Marie L Cooke: nothing to declare Marion Mitchell: nothing to declare Frances Lin: nothing to declare Karen New: has received a research grant from The University of Queensland for research related to preconception and early pregnancy care; has been paid for preparing and delivering education on obtaining informed consent for research; and as the Professional Officer of the Australian College of Neonatal Nurses has been supported by an unrestricted eduction grant from Johnson and Johnson Pacific to deliver education on the AWHONN skin care guidelines and the Every Newborn Action Plan. Debbie A Long: nothing to declare Gabor Mihala: nothing to declare
Editorial base comment: this review is not currently compliant with Cochrane's Commercial Sponsorship policy. The review is expected to be updated within the next twelve months and the majority of authors and the Lead Author will be free of conflicts of interest for this new update.
Edited (no change to conclusions)
References
References to studies included in this review
Arvaniti 2012 {published data only}
- Arvaniti K, Lathyris D, Clouva‐Molyvdas P, Haidich AB, Mouloudi E, Synnefaki E, et al. Comparison of oligon catheters and chlorhexidine impregnated sponges with standard multilumen central venous catheters for prevention of associated colonization and infections in intensive care unit patients: a multicenter, randomized, controlled trial. Critical Care Medicine 2012;40(2):420‐9. [PUBMED: 21926583] [DOI] [PubMed] [Google Scholar]
Brandt 1996 {published data only}
- Brandt B, DePalma J, Irwin M, Shogan J, Lucke J. Comparison of central venous cathter dressings in bone marrow transplant recipients. Oncology Nursing Forum 1996;23(5):829‐36. [PUBMED: 8792352] [PubMed] [Google Scholar]
Carrer 2005 {published data only}
- Carrer S, Bocchi A, Bortolotti M, Braga N, Gilli G, Candini M, et al. Effect of different sterile barrier precautions and central venous catheter dressing on the skin colonization around the insertion site. Minerva Anestesiologica 2005;71(5):197‐206. [PUBMED: 15834348] [PubMed] [Google Scholar]
Chambers 2005 {published data only}
- Chambers S, Sanders J, Patton W, Ganly P, Birch M, Crump J, et al. Reduction of exit‐site infections of tunnelled intravascular catheters among neutropenic patients by sustained‐release chlorhexidine dressings: results from a prospective randomized controlled trial. Journal of Hospital Infection 2005;61:53‐61. [PUBMED: 16002181] [DOI] [PubMed] [Google Scholar]
Conly 1989 {published data only}
- Conly JM, Grieves K, Peters B. A prospective, randomized study comparing transparent and dry gauze dressings for central venous catheters. The Journal of Infectious Diseases 1989;159(2):310‐9. [PUBMED: 2644372] [DOI] [PubMed] [Google Scholar]
de Barros 2009 {published data only}
- Barros L, Arenas V, Bettencourt A, Diccini S, Fram D, Belasco A, et al. Evaluation of two types of dressings used on central venous catheters for hemodialysis. Acta Paulista de Enfermagem 2009;22(Especial ‐ Nefrologia):481‐6. [Google Scholar]
Garland 2001 {published data only}
- Garland J, Alex C, Mueller C, Otten D, Shivpuri C, Harris M, et al. A randomized trial comparing povidone‐iodine to a chlorhexidine gluconate‐impregnated dressing for prevention of central venous catheter infections in neonates. Pediatrics 2001;107(6):1431‐7. [PUBMED: 11389271] [DOI] [PubMed] [Google Scholar]
Giles 2002 {published data only}
- Giles Y, Aksoy A, Tezelman S. What really affects the incidence of central venous catheter‐related infections for short‐term catheterization. Acta Chirugica Belgica 2002;102(4):256‐8. [PUBMED: 12244905] [DOI] [PubMed] [Google Scholar]
Hagerstrom 1994 {published data only}
- Hagerstrom M, Matthiesen K, Thuessen C. [An improved dressing method for haemodialysis patients with permanent central venous catheters]. Associazione Infermieristica per lo Studio delle Lesioni Cutanee. 1994. [http://www.aislec.it/download2010/1190.pdf]
Hill 2010 {published data only}
- Hill M, Baldwin L, Slaughter J, Walsh W, Weitkamp J. A silver‐alginate‐coated dressing to reduce peripherally inserted central catheter infections in NICU patients: a pilot randomized controlled trial. Journal of Perinatology 2010;30:469‐73. [PUBMED: 20010613] [DOI] [PubMed] [Google Scholar]
le Corre 2003 {published data only}
- Corre L, Delorme M, Cournoyer S. A prospective, randomized trial comparing a transparent dressing and a dry gauze on the exit site of long term central venous catheters of hemodialysis patients. The Journal of Vascular Access 2003;4(2):56‐61. [PUBMED: 17642061] [PubMed] [Google Scholar]
Levy 2005 {published and unpublished data}
- Levy I, Katz J, Solter E, Samra Z, Vidne B, Birk E, et al. Chlorhexidine‐impregnated dressing for prevention of colonization of central venous catheters in infants and children. Pediatric Infectious Disease Journal 2005;24(8):676‐9. [PUBMED: 16094219] [DOI] [PubMed] [Google Scholar]
Nikoletti 1999 {published and unpublished data}
- Nikoletti S, Leslie G, Gandossi S, Coombs G, Wilson R. A prospective, randomized, controlled trial comparing transparent polyurethane and hydrocolloid dressings for central venous catheters. American Journal of Infection Control 1999;27(6):488‐96. [PUBMED: 10586152] [DOI] [PubMed] [Google Scholar]
Olson 2004 {published and unpublished data}
- Olson K, Rennie R, Hanson J, Ryan M, Gilpin J, Falsetti M, et al. Evaluation of a no‐dressing intervention for tunneled central venous catheter exit sites. Journal of Infusion Nursing 2004;27(1):37‐55. [PUBMED: 14734986] [DOI] [PubMed] [Google Scholar]
Pedrolo 2011 {published and unpublished data}
- Pedrolo E, Danski M, Mingorance P, Lazzari L, Johann D. Clinical controlled trial on central venous catheter dressings. Acta Paulista de Enfermagem 2011;24(2):278‐83. [Google Scholar]
Roberts 1998 {published data only}
- Roberts B, Cheung D. Biopatch ‐ a new concept in antimicrobial dressings for invasive devices. Australia Critical Care 1998;11(1):16‐9. [PUBMED: 9708081] [DOI] [PubMed] [Google Scholar]
Ruschulte 2009 {published data only}
- Ruschulte H, Franke M, Gastmeier P, Zenz S, Nahr K, Buchholz S, et al. Prevention of central venous catheter related infections with chlorhexidine gluconate impregnated wound dressings: a randomized controlled trial. Annals of Hematology 2009;88:267‐72. [PUBMED: 18679683] [DOI] [PubMed] [Google Scholar]
Shivnan 1991 {published data only}
- Shivnan J, McGuire D, Freedman S, Sharkazy E, Bosserman G, Larson E, et al. A comparison of transparent adherent and dry sterile gauze dressings for long‐term central catheters in patients undergoing bone marrow transplant. Oncology Nursing Forum 1991;18(8):1349‐56. [PUBMED: 1762975] [PubMed] [Google Scholar]
Timsit 2009 {published and unpublished data}
- Roush K. Drug‐impregnated sponges for preventing catheter‐related infections. American Journal of Nursing 2009;109(11):65. [PUBMED: 19858861] [DOI] [PubMed] [Google Scholar]
- Timsit JF, Schwebel C, Duoadma L, Geffroy M, Pease S, Herault MC, et al. Chlorhexidine‐impregnated sponges and less frequent dressing changes for prevention of catheter‐related infections in critically ill adults. JAMA 2009;301(12):1231‐40. [PUBMED: 19318651] [DOI] [PubMed] [Google Scholar]
Timsit 2012 {published and unpublished data}
- Timsit JF, Mimoz O, Mourvillier B, Souweine B, Garrouste‐Orgeas M, Alfandari S, et al. Randomized controlled trial of chlorhexidine dressing and highly adhesive dressing for preventing catheter‐related infections in critically ill adults. American Journal of Respiratory and Critical Care Medicine 2012;186(12):1272‐8. [PUBMED: 23043083] [DOI] [PubMed] [Google Scholar]
Wille 1993 {published data only}
- Wille J, Blusse van Oud Alblas A, Thewessen E. A comparison of two transparent film‐type dressings in central venous therapy. Journal of Hospital Infection 1993;23:113‐21. [PUBMED: 8097215] [DOI] [PubMed] [Google Scholar]
Yamamoto 2002 {published and unpublished data}
- Yamamoto A, Solomon J, Soulen M, Tang J, Parkinson K, Lin R, et al. Sutureless securement device reduces complications of peripherally inserted central venous catheters. Journal of Vascular and Interventional Radiology 2002;13:77‐81. [PUBMED: 11788698] [DOI] [PubMed] [Google Scholar]
References to studies excluded from this review
Crawford 2004 {published data only}
- Crawford A, Fuhr J, Rao B. Cost‐benefit analysis of chlorhexidine gluconate dressing in the prevention of catheter‐related bloodstream infection. Infection Control and Hospital Epidemiology 2004;25(8):668‐74. [PUBMED: 15357159] [DOI] [PubMed] [Google Scholar]
Davidson 1986 {published data only}
- Davidson L. Dressing subclavian catheters. Nursing Times 1986;82(7):40. [PUBMED: 3083404] [PubMed] [Google Scholar]
Freiberger 1992 {published data only}
- Freiberger D, Bryant J, Marino B. The effects of different central venous line dressing changes on bacterial growth in a pediatric oncology population. Journal of Pediatric Oncology Nursing 1992;9(1):3‐6. [PUBMED: 1596385] [DOI] [PubMed] [Google Scholar]
George 2011 {published data only}
- George J, Singh S, Deepshikha, John M. A prospective randomized comparative study between transparent and occlusive dressings for central venous catheters. Indian Journal of Hematology and Blood Transfusion. 2011; Vol. 27 (4):286.
Keenlyside 1991 {published data only}
- Keenlyside D. Central venous catheters ‐ a randomized comparative study of OpSite IV3000 and Tegaderm. In: Maki D editor(s). Improving Catheter Site Care. Royal Society of Medicine Services Limited, 1991:47‐50. [Google Scholar]
Keenlyside 1993 {published data only}
- Kennlyside D. Avoiding an unnecessary outcome: a comparative trial between IV3000 and a conventional film dressing to assess rates of catheter‐related sepsis. Professional Nurse 1993;8(5):288‐91. [PUBMED: 8451247] [PubMed] [Google Scholar]
Khattak 2010 {published data only}
- Khattak A, Ross R, Ngo T, Shoemaker C. A randomized controlled evaluation of absorption of silver with the use of silver alginate (Algidex) patches in very low birth weight (VBLW) infants with central lines. Journal of Perinatology 2010;30:337‐42. [PUBMED: 19940856] [DOI] [PubMed] [Google Scholar]
Lawson 1986 {published data only}
- Lawson M, Kavanagh T, McCredie K, Marts K, Barbour N, Chandler W. Comparison to transparent dressing to paper tape dressing over central venous catheter sites. Journal of the National Intravenous Therapy Association 1986;9:40‐3. [PUBMED: 3633416 ] [PubMed] [Google Scholar]
Little 1998 {published data only}
- Little K, Palmer D. Central line exit sites: which dressing?. Nursing Standard 1998;12(48):42‐6. [PUBMED: 9823178] [DOI] [PubMed] [Google Scholar]
Lucas 1996 {published data only}
- Lucas H, Attard‐Montalto S. Central line dressings: study of infection rates. Paediatric Nursing 1996;8(6):21‐3. [PUBMED: 8718254] [PubMed] [Google Scholar]
Madeo 1998 {published data only}
- Madeo M, Martin C, Turner C, Kirkby V, Thompson D. A randomized trial comparing Arglaes (a transparent dressing containing silver ions) to Tegaderm (a transparent polyurethane dressing) for dressing peripheral arterial catheters and central vascular catheters. Intensive and Critical Care Nursing 1998;14:187‐91. [PUBMED: 9849245] [DOI] [PubMed] [Google Scholar]
Maki 1984 {published and unpublished data}
- Maki D, Wili L. Colonisation and infection associated with transparent dressings for central venous arterial and hickman catheters: a comparative trial. Program and Abstracts of the 24th Interscience Conference on Antimicrobial Agents and Chemotherapy. Washington, DC, 1984.
Maki 2000 {published data only (unpublished sought but not used)}
- Maki DG, Mermel LA, Kluger D, Narans L, Knasinski V, Parenteau S, et al. The efficacy of a chlorhexidine‐impregnated sponge (biopatch) for the prevention of intravascular catheter‐related infection ‐ a prospective, randomized, controlled, multicenter study. Abstracts of the 40th Interscience Conference on Antimicrobial Agents and Chemotherapy. 2000:422.
Neufeld 1991 {published and unpublished data}
- Neufeld M. A randomized control trial of the effectiveness of opsite wound versus IV 3000 in maintaining an occlusive central line dressing. Open Access Dissertations and Theses 1991; Vol. Paper 4057. [http://Digitalcommons.mcmaster.ca/opendissertations/4057]
Olson 2008 {published data only}
- Olson C, Heilman J and the Vascular Access Team of Abbott Northwestern Hospital. Clinical performance of a new transparent chlorhexidine gluconate central venous catheter dressing. Journal for the Association for Vascular Access 2008;13(1):13‐6. [Google Scholar]
Petrosino 1988 {published data only}
- Petrosino B, Becker H, Christian B. Infection rates in central venous catheter dressings. Oncology Nursing Forum 1988;15(6):709‐17. [PUBMED: 3144709] [PubMed] [Google Scholar]
Powell 1982 {published data only}
- Powell C, Regan C, Fabri P, Ruberg R. Evaluation of opsite catheter dressings for parenteral nutrition: a prospective, randomized study. Journal of Parenteral and Enteral Nutrition 1982;6(1):43‐6. [PUBMED: 6804654] [DOI] [PubMed] [Google Scholar]
Powell 1985 {published data only}
- Powell C, Traetow M, Fabri P, Kudsk K, Ruberg R. Op‐site dressing study: a prospective randomized study evaluating povidine iodine ointment and extension set changes with 7‐day Op‐site dressings applied to total parental nutrition subclavian sites. Journal of Parenteral and Enteral Nutrition 1985;9(4):443‐8. [PUBMED: 3928918] [DOI] [PubMed] [Google Scholar]
Reynolds 1997 {published data only}
- Reynolds M, Tebbs S, Elliot T. Do dressings with increased permeability reduce the incidence of central venous catheter related sepsis?. Intensive and Critical Care Nursing 1997;13:26‐9. [PUBMED: 9095879] [DOI] [PubMed] [Google Scholar]
Schwebel 2012 {published data only}
- Schwebel D, Lucet JC, Vesin A, Arrault X, Calvino‐Gunther S, Bouadma L, et al. Economic evaluation of chlorhexidine‐impregnated sponges for preventing catheter‐related infections in critically ill adults in the Dressing Study. Critical Care Medicine 2012;40(1):11‐8. [PUBMED: 21926570] [DOI] [PubMed] [Google Scholar]
Timsit 2010 {published data only}
- Timsit JF, Schwebel C, Vegin A, Bouadma L, Geffroy A, Garrouste‐Orgeas M, et al. Cost‐benefit of a chlorhexidine impregnated sponges for prevention of catheter‐related infections in adult ICU patients. 23rd ESICM Annual Congress. 2010:S207.
References to studies awaiting assessment
Broadhurst 2014 {published data only}
- Broadhurst D. PICC catheter securement: a randomized controlled trial in the home care setting. Journal of Vascular Access. 2015; Vol. 15:218‐9.
Calvino 2014 {published data only}
- Calvino GS, Chautemps M, Schwebel C, Sengel E, Ruckly S, Djaguidi MR, et al. Performance of new high performance dressings as compared to traditional ones in prevention infection and non‐infection complications of catheters in ICU: a randomized controlled study. Intensive Care Medicine. 2014:S240.
Gu 2014 {published data only}
- Gu Y, Yuan J, Hu J, Gong WJ. Transparent dressing versus iodine plus dressing and high‐permeability dressing in pediatric central line maintenance: a randomize controlled study. Pediatric Critical Care Medicine. 2014.
Pedrolo 2014 {published data only}
- Pedrolo E, Danski M, Vayego S. Chlorhexidine and gauze and tape dressings for central venous catheters: a randomized clinical trial. Revista Latino‐Americana de Engermagem 2014;22(5):764‐71. [PUBMED: 4292677] [DOI] [PMC free article] [PubMed] [Google Scholar]
Additional references
Chaimani 2013
- Chaimani A, Higgins JPT, Mavridis D, Spyridonos P, Salanti G. Graphical Tools for Network Meta‐Analysis in STATA. PLoS ONE 2013;8(10):e76654. [DOI: 10.1371/journal.pone.0076654] [DOI] [PMC free article] [PubMed] [Google Scholar]
Deeks 2011
- Deeks J, Higgins JPT, Altman DG. Chapter 9: Analysing data and undertaking meta‐analyses. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011. Available from www.cochrane‐handbook.org.
Egger 1997
- Egger M, Smith GD, Schneider M, Minder C. Bias in meta‐analysis detected by a simple, graphical test. BMJ 1997;315(7109):629‐34. [PUBMED: 9310563] [DOI] [PMC free article] [PubMed] [Google Scholar]
Frasca 2010
- Frasca D, Dahyot‐Fizelier C, Mimoz O. Prevention of central venous catheter‐related infection in the intensive care unit. Critical Care 2010;14:212. [DOI] [PMC free article] [PubMed] [Google Scholar]
Han 2010
- Han Z, Liang S, Marschall J. Current strategies for the prevention and management of central line‐associated bloodstream infections. Infection and Drug Resistance 2010;10(3):147‐63. [DOI] [PMC free article] [PubMed] [Google Scholar]
Higgins 2003
- Higgins J, Thompson S, Deeks J, Altman D. Measuring inconsistency in meta‐analyses. BMJ 2003;327(7414):557‐60. [DOI] [PMC free article] [PubMed] [Google Scholar]
Higgins 2011a
- Higgins JPT, Altman DG, Stern JAC. Chapter 8: Assessing risk of bias in included studies. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011. Available from www.cochrane‐handbook.org.
Higgins 2011b
- Higgins JPT, Deeks JJ, Altman DG (editors). Chapter 16: Special topics in statistics. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011. Available from www.cochrane‐handbook.org.
Ho 2006
- Ho KM, Litton E. Use of chlorhexidine‐impregnated dressing to prevent vascular and epidural catheter colonization and infection: a meta‐analysis. The Journal of Antimicrobial Chemotherapy 2006;58(2):281‐7. [PUBMED: 16757502] [DOI] [PubMed] [Google Scholar]
Kampf 2005
- Kampf G, Wigger‐Alberti W, Schoder V, Wilhelm K. Emollients in a propanol‐based hand rub can significantly decrease irritant contact dermatitis. Contact Dermatitis: Environmental and Occupational Dermatitis 2005;53(6):344‐9. [PUBMED: 16364124 ] [DOI] [PubMed] [Google Scholar]
Lefebvre 2011
- Lefebvre C, Manheimer E, Glanville F. Chapter 6: Searching for studies. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The CochraneCollaboration, 2011. Available from www.cochrane‐handbook.org.
Liberati 2009
- Liberati A, Alteman DG, Tetzlaff J, Murow C, Gotzsche PC, Ionnidis JP, et al. The PRISMA statement for reporting systematic reviews and meta‐analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Medicine 2009;6:e1000100. [DOI] [PMC free article] [PubMed] [Google Scholar]
Loveday 2014
- Loveday HP, Wilson JA, Pratt RJ, Golsorkhi M, Tingle A, Bak A, et al. epic3: National evidence‐based guidelines for preventing healthcare‐associated infections in NHS in England. Journal of Hospital Infection 2014;86:S1‐S70. [PUBMED: 24330862] [DOI] [PMC free article] [PubMed] [Google Scholar]
Maki 2006
- Maki DG, Kluger DM, Crnich CJ. The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clinic Proceedings 2006;81(9):1159‐71. [DOI] [PubMed] [Google Scholar]
Mermel 2009
- Mermel LA, Allon M, Bouza E, Craven DE, Flynn P, O'Grady N, et al. Clinical practice guidelines for the diagnosis and management of intravascular catheter‐related infection: 2009 update by the Infectious Diseases Society of America. Clinical Infectious Diseases 2009;49:1‐45. [DOI] [PMC free article] [PubMed] [Google Scholar]
Naimer 2004
- Naimer S, Temira F. Evaluation of techniques for intravenous catheter and tubing fixation. Military Medicine 2004;169(1):79‐81. [DOI] [PubMed] [Google Scholar]
O'Grady 2002
- O'Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, et al. Guidelines for the prevention of intravascular catheter‐related infections. Morbidity and Mortality Weekly Report 2002;51(RR‐10):1‐29. [PubMed] [Google Scholar]
O'Grady 2011
- O'Grady N, Alexander M, Burns L, Dellinger E, Garland J, Heard S, et al. Guidelines for the prevention of intravascular catheter‐related infections. Clinical Journal of Infectious Diseases 2011 May;52(9):1087‐99. [DOI] [PMC free article] [PubMed] [Google Scholar]
Parmar 1998
- Parmar MKB, Torri V, Stewart L. Extracting summary statistics to perform meta‐analyses of the published literature for survival endpoints. Statistics in Medicine 1998;17:2815‐34. [PUBMED: 9921604] [DOI] [PubMed] [Google Scholar]
Pronovost 2006
- Pronovost P, Needham D, Berenholtz S, Sinopoli D, Chu H, Cosgrove S, et al. An intervention to decrease catheter‐related bloodstream infections in the ICU. New England Journal of Medicine 2006;355(26):2725‐32. [DOI] [PubMed] [Google Scholar]
Raad 2007
- Raad I, Hanna H, Maki D. Intravascular catheter‐related infections: advances in diagnosis, prevention, and management. Lancet 2007;7:645‐57. [DOI] [PubMed] [Google Scholar]
Reeves 2011
- Reeves BC, Deeks JJ, Higgins JPT, Wells GA. Chapter 13: Including non‐randomized studies. In: Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011. Available from www.cochrane‐handbook.org.
RevMan 2014 [Computer program]
- The Nordic Cochrane Centre, The Cochrane Collaboration. Review Manager (RevMan). Version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014.
Safdar 2014
- Safdar N, O'Horo JC, Ghufran A, Bearden A, Didier ME, Chateau D, et al. Chlorhexidine‐impregnated dressing for prevention of catheter‐related bloodstream infection: a meta‐analysis. Critical Care Medicine 2014;42(7):1703‐13. [PUBMED: 24674924] [DOI] [PMC free article] [PubMed] [Google Scholar]
Salanti 2008
- Salanti G, Higgins J, Ades AE, Ioannidis JP. Evaluation of networks of randomized trials. Statistical Methods in Medical Research 2008;17(3):279‐301. [DOI] [PubMed] [Google Scholar]
Salanti 2014
- Salanti G, Giovane C, Chaimani A, Caldwell DM, Higgins JPT. Evaluating the Quality of Evidence from a Network Meta‐Analysis. PLoS ONE 2014;9(7):e99682. [DOI: ] [DOI] [PMC free article] [PubMed] [Google Scholar]
Schulz 2010
- Schulz KF, Altman DF, Moher D, CONSORT Group. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. International Journal of Surgery 2011;9(8):672‐7. [PUBMED: 22019563] [DOI] [PubMed] [Google Scholar]
Schunemann 2011
- Schunemann HJ, Oxman AD, Vist GE, Higgins JPT, Deeks JJ, Glasziou P, et al. Chapter 12: Interpreting results and drawing conclusions. In: Higgins JPT, Green S (editors), Cochrane Hanbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011. Available from www. cochrane‐handbook.org.
SIGN 2012
- Scottish Intercollegiate Guidelines Network (SIGN). Search filters. www.sign.ac.uk/methodology/filters.html#random (accessed 19 November 2012).
StataCorp 2011 [Computer program]
- StataCorp. Stata Statistical Software: Release 12. College Station TX: StataCorp LP, 2011.
Timsit 2011
- Timsit JF, Duboid Y, Minet C, Bonadona A, Lugosi M, Ara‐Somohano C, et al. New materials and devices for preventing catheter‐related infections. Annals of Intensive Care 2011;1:34. [PUBMED: 21906266] [DOI] [PMC free article] [PubMed] [Google Scholar]
Webster 2011
- Webster J, Gillies D, O'Riordan E, Sherriff KL, Rickard CM. Gauze and tape and transparent polyurethane dressings for central venous catheters. Cochrane Database of Systematic Reviews 2011, Issue 11. [DOI: 10.1002/14651858.CD003827.pub2] [DOI] [PubMed] [Google Scholar]
White 2012
- White IR, Barrett JK, Jackson D, Higgins JPT. Consistency and inconsistency in network meta‐analysis: model estimation using multivariate meta‐regression. Research Synthesis Methods 2013;3:111‐25. [DOI] [PMC free article] [PubMed] [Google Scholar]