Abstract
This study models the amount of contrast that could be conserved in computed tomographic examinations in the context of the current global shortage of iodinated contrast media.
In April 2022, a global shortage of iodinated contrast media occurred due to a COVID-19–induced supply chain disruption of GE Healthcare in Shanghai, China.1 This shortage is expected to last until at least summer of 2022 and will affect millions of examinations.
Approximately 54.4 million diagnostic imaging examinations using contrast are conducted annually in the US, including nearly all angiography and 48% of the 91.4 million computed tomography (CT) scans performed in 2019.2,3
Strategies to minimize patient harm include canceling or delaying tests that have little patient benefit or are not time sensitive. For indicated examinations, alternative tests with similar diagnostic accuracy could be considered.
For CT examinations that usually use contrast, several approaches could potentially conserve contrast. For example, unenhanced CT can have similar or only modestly lower diagnostic accuracy as contrast-enhanced CT for many indications. The volume of administered contrast can be reduced by using weight-based dosing,4 lower tube voltage,5 or a combination of these methods. At present, there is no standard contrast dosing strategy across centers.4 Additionally, there are different strategies for delivering contrast, and fixed-volume vials (in which the residual is discarded) result in waste compared with multidose vials.4 We modeled the amount of contrast that could be conserved in CT examinations.
Methods
We considered 5 alternative strategies for conserving contrast during CT imaging: weight-based dosing4 (model A), reducing contrast dose while reducing tube voltage5 (model B), replacing contrast CT with unenhanced CT if no more than moderate negative effect on diagnostic accuracy is predicted using the American College of Radiology Appropriateness Criteria6 (model C), a combination of models A and C (model D), and a combination of models A, B, and C (model E) (Table 1). The eTable in the Supplement provides the detailed rules of each contrast-conserving strategy by clinical indication. We applied these rules to observed contrast use in each examination in a sample of 1.04 million CT examinations in the UCSF International CT Dose Registry performed January 1, 2015, to March 11, 2021, to estimate total expected contrast use at baseline (40% of scans used contrast in the registry during included years) and in each of the 5 hypothetical strategies (eMethods in the Supplement). All contrast volumes were modeled using an iodine concentration of 300 mg iodine/mL. The registry pools consecutive CT scans performed at 161 imaging facilities associated with 27 health care organizations.7 We scaled the results (using data on age, weight, indication, and contrast use) to a hypothetical population of 1 million CT scans in adults and calculated percent reductions in total contrast usage from baseline. The base case assumed multiuse vials were available. The sensitivity analyses assumed practices had access to typical single-use vials of various doses (excess volume wasted). Simulations used SAS, version 9.3 (SAS Institute).
Table 1. Model Assumptions.
| Model/analysis | Description |
|---|---|
| Base modela | Fixed dosing: 100 mL for brain CT; 120 mL for neck, chest, abdomen, pelvis, spine, and extremity CT; 10 mL for myelograms |
| A: Weight-based dosing for nonneurological CT |
|
| B: Reduce kV and contrast media dose if patient weight is <80 kg |
|
| C: Perform unenhanced CT instead of contrast-enhanced CT if predicted to have moderate or less effect on accuracy | All contrast-enhanced CT examinations in which contrast media not essential were changed to unenhanced examinations (see eTable in the Supplement); this reflects most nonvascular examinations and is based on American College of Radiology Appropriateness Criteria6 |
| D: Combination of models A and C | Weight-based dosing for nonneurological CT, combined with use of unenhanced CT if contrast not essential |
| E: Combination of models A, B, and C | Weight-based dosing for nonneurological CT, combined with reduced kV and reduced contrast dose for patients <80 kg and use of unenhanced CT if contrast not essential |
| Sensitivity analysis 1: fixed dosing; 20-, 50-, and 100-mL single-use vials availableb | 20-, 40-, 50-, 60-, 70-, 80-, 90-, 100-, 110-, and 120-mL doses possible from available vials without waste; other doses rounded up to these values and the total estimate includes the resulting waste |
| Sensitivity analysis 2: fixed dosing; only 50-mL vials availableb | 50- and 100-mL doses possible without waste; other doses rounded up to 50, 100, or 150 mL and the total estimate includes the resulting waste |
| Sensitivity analysis 3: fixed dosing; only 100-mL vials availableb | 100-mL doses possible without waste; other doses rounded up to 100 or 200 mL and the total estimate includes the resulting waste |
The distribution in patient age, weight, type of examinations by body region and indication for scanning, and use of iodinated intravenous contrast across these patient variable and computed tomographic (CT) types (see eTable in the Supplement) was based on their distribution in the University of California San Francisco International CT Dose Registry.7
In normal conditions without supply chain compromise, contrast is available in multiuse vials (in which exact volumes can be given to multiple patients but requiring a particular type of contrast injector) and single-use vials (can be given to individual patients, with or without combination of several single-use vials, where excess volume must be discarded). When all vial sizes are available, this is similar to exact dosing without access to the particular type of contrast injector.
Results
For the base case, 47.1 million mL of contrast was estimated to be used for the 1 million CT scans (Table 2). The model estimated that weight-based dosing would reduce use by 12% (to 41.6 million mL) and that reducing tube voltage and contrast dose would reduce use by 25% (to 35.4 million mL). The model estimated that the greatest reduction (78% [to 10.5 million mL]) would involve performing unenhanced CT instead of contrast-enhanced CT when moderate reduction in diagnostic accuracy is acceptable. Combining all 3 approaches was estimated to achieve an 83% reduction (to 7.8 million mL) (Table 2). The base case estimate for single-use 100-mL vials would be 77.7 million mL vs an estimated 47.1 million mL for multiuse vials, but the relative benefits of the different reduction strategies are similar.
Table 2. Estimated Use of Intravenous Contrast Media (300 mg Iodine/mL) Under Different Scenarios for Conserving Use in a Modeled Population of 1 Million US Adultsa.
| Model | Multiuse vials exact dosing, mL | Single-use vials availableb | ||
|---|---|---|---|---|
| 20, 50, and 100 mL | 50 and 100 mL | 100 mL | ||
| Baseline | 47 125 410 | 47 149 640 | 58 589 480 | 77 655 880 |
| A: Weight-based dosing for nonneurological CT | 41 587 660 | 42 680 090 | 52 228 400 | 64 983 650 |
| Reduction, % | 12 | 9 | 11 | 16 |
| B: Reduce kV and contrast media dose for patients <80 kg | 35 441 330 | 35 776 420 | 42 635 220 | 62 112 100 |
| Reduction, % | 25 | 24 | 27 | 20 |
| C: Perform unenhanced CT instead of contrast-enhanced CT if predicted to have moderate or less effect on accuracy | 10 477 420 | 10 477 420 | 13 053 520 | 17 347 010 |
| Reduction, % | 78 | 78 | 78 | 78 |
| D: Combination of models A and C | 9 390 820 | 9 609 910 | 11 824 800 | 14 899 430 |
| Reduction, % | 80 | 80 | 80 | 81 |
| E: Combination of models A, B, and C | 7 812 000 | 7 933 770 | 9 447 450 | 13 693 130 |
| Reduction, % | 83 | 83 | 84 | 82 |
Data are total volume in mL and percent reduction in mL compared with the baseline models. The model inputs were based on a sample of 1.04 million computed tomography (CT) examinations from the University of California San Francisco International CT Dose Registry7 that had nonmissing patient age, body weight, CT examination types by indication, and use of contrast across these patient factors (see eTable in the Supplement), scaled to a population of 1 million adults.
Patient dose does not vary between multiuse and single-use estimates. The higher estimated volumes associated with single-use vials reflect waste from discarded unused volume.
Discussion
This modeling study estimated that intravenous contrast use for CT scans could be reduced by approximately 80% by using a combination of dose-reduction strategies. This analysis had several limitations. The lower prevalence of contrast use in the registry (40%) vs the national estimate (48%) indicates that the percent reductions calculated in the various strategies are underestimated. The reduction in diagnostic accuracy and potential harm to patients from withholding contrast was not modeled, nor was repackaging of larger single-use vials to smaller single-use vials. The study was limited to CT scans, but other examinations, particularly catheter angiography, also use contrast. Adoption of some of the dose-reduction strategies beyond the current shortage could mitigate supply chain risk and remove waste.
Section Editors: Jody W. Zylke, MD, Deputy Editor; Kristin Walter, MD, Senior Editor.
eMethods
eTable. The use of intravenous or intrathecal contrast by CT indication in the UCSF International CT Dose Registry, and the effect of dose-conserving models on contrast use
References
- 1.Current drug shortages: iohexol injection. American Society of Health-System Pharmacists . Published May 3, 2022. Accessed May 9, 2022. https://www.ashp.org/drug-shortages/current-shortages/drug-shortage-detail.aspx?id=830&loginreturnUrl=SSOCheckOnly
- 2.Young L. CT contrast media utilization reaches a crossroads. imv. March 27, 2020. Accessed May 27, 2022. https://imvinfo.com/ct-contrast-media-utilization-reaches-a-crossroads/
- 3.2019. Fixed C-arm market outlook report. imv. Accessed May 19, 2022. https://imvinfo.com/product/2019-fixed-c-arm-market-outlook-report/
- 4.Davenport MS, Parikh KR, Mayo-Smith WW, Israel GM, Brown RK, Ellis JH. Effect of fixed-volume and weight-based dosing regimens on the cost and volume of administered iodinated contrast material at abdominal CT. J Am Coll Radiol. 2017;14(3):359-370. doi: 10.1016/j.jacr.2016.09.001 [DOI] [PubMed] [Google Scholar]
- 5.Canstein C, Korporaal J. Reduction of contrast agent dose: scanning at low kV. Siemens Healthineers; 2020. Accessed May 9, 2022. https://cdn0.scrvt.com/39b415fb07de4d9656c7b516d8e2d907/87ec6e04a7686fe0/375ae3698b98/ct_whitepaper_contrast-agent-dose-at-low-kv-02015844.pdf
- 6.Kurth DA, Karmazyn BK, Waldrip CA, Chatfield M, Lockhart ME. ACR Appropriateness Criteria methodology. J Am Coll Radiol. 2021;18(11S):S240-S250. doi: 10.1016/j.jacr.2021.03.021 [DOI] [PubMed] [Google Scholar]
- 7.Smith-Bindman R, Yu S, Wang Y, et al. An image quality-informed framework for CT characterization. Radiology. 2022;302(2):380-389. doi: 10.1148/radiol.2021210591 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
eMethods
eTable. The use of intravenous or intrathecal contrast by CT indication in the UCSF International CT Dose Registry, and the effect of dose-conserving models on contrast use