Due to a publishing error the article: “The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials”, published at Journal of Applied Oral Science 2022;30:e20220161 was printed with the following error:
Where it reads:
Figure 1. The heat-cured denture base materials used in the study.
* According to the manufacturers’ information. MMA: Methyl methacrylate, PMMA: Polymethyl methacrylate, BPO: Benzoyl peroxide, HQ: Hydroquinone, EGDMA: Ethyleneglycol dimethacrylate, BDMA: Tetramethylene dimethacrylate
It should read:
Figure 1. The heat-cured denture base materials used in the study.
* According to the manufacturers’ information. MMA: Methyl methacrylate, PMMA: Polymethyl methacrylate, BPO: Benzoyl peroxide, HQ: Hydroquinone, EGDMA: Ethyleneglycol dimethacrylate, BDMA: Tetramethylene dimethacrylate
Where it reads:
Table 1. The results of the MMA concentration in the water-eluents of the heat-cured PMMA denture base materials tested*.
| Cooling procedures | MMA eluted in water (ppm) | |||
|---|---|---|---|---|
| PA | PB | QC | VE | |
| A | 4.6<LoQ | 4.6<LoQ | 8.5 (1.7)a,A | 6.4 (0.3)b,A |
| B | <LoD | 2.1<LoQ | <LoD | 8.7 (2.4)b |
| C | <LoD | 4.8<LoQ | 13.2 (2.4)a | 2.9<LoQ |
| D | 2.8<LoQ | 2.2<LoQ | <LoD | 3.2<LoQ |
| E | <LoD | <LoD | <LoD | 4.2<LoQ |
| Control | <LoD | <LoD | <LoD | <LoD |
* Means and standand deviations (in parentheses).Superscript letters show mean values with insignificant differences within each material group (lower case) and between material groups per treatment (upper case). LoQ: Lower limit of quantitation (5.90 ppm), LoD: Limit of detection (1.95 ppm). Bold characters show the values obtained using the cooling modes suggested by the manufacturers. Data given for results <LoQ represent only mean values
It should read:
Table 1. The results of the MMA concentration in the water-eluents of the heat-cured PMMA denture base materials tested*.
| Cooling procedures | MMA eluted in water (ppm) | |||
|---|---|---|---|---|
| PA | PB | QC | VE | |
| A | 4.6<LoQ | 4.6<LoQ | 8.5 (1.7)a,A | 6.4 (0.3)b,A |
| B | <LoD | 2.1<LoQ | <LoD | 8.7 (2.4)b |
| C | <LoD | 4.8<LoQ | 13.2 (2.4)a | 2.9<LoQ |
| D | 2.8<LoQ | 2.2<LoQ | <LoD | 3.2<LoQ |
| E | <LoD | <LoD | <LoD | 4.2<LoQ |
| Control | <LoD | <LoD | <LoD | <LoD |
* Means and standand deviations (in parentheses).Superscript letters show mean values with insignificant differences within each material group (lower case) and between material groups per treatment (upper case). LoQ: Lower limit of quantitation (5.90 ppm), LoD: Limit of detection (1.95 ppm). Bold characters show the values obtained using the cooling modes suggested by the manufacturers. Data given for results <LoQ represent only mean values


