Skip to main content
PLOS Global Public Health logoLink to PLOS Global Public Health
. 2022 Apr 11;2(4):e0000358. doi: 10.1371/journal.pgph.0000358

Diagnostic accuracy of antigen-detection rapid diagnostic tests for diagnosis of COVID-19 in low-and middle-income countries: A systematic review and meta-analysis

Sagar Pandey 1,*, Arisa Poudel 2, Dikshya Karki 3, Jeevan Thapa 4
Editor: Raquel Muñiz-Salazar5
PMCID: PMC10021667  PMID: 36962195

Abstract

Antigen detection rapid diagnostic tests (Ag-RDTs) used for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid protein are inexpensive, faster and easy to use alternative of Nucleic Acid Amplification Test (NAAT) for diagnosis of Coronavirus disease 2019 (COVID-19). In this systematic review and meta-analysis, we assessed the diagnostic accuracy of Ag-RDTs in low and middle-income countries (LMICs). We included studies that evaluated the diagnostic accuracy of Ag-RDTs (sensitivity and specificity) against reverse transcription-polymerase chain reaction (RT-PCR) as a reference standard. The study population comprised of people living in LMICs irrespective of age and gender, who had undergone testing for COVID-19. We included peer reviewed prospective or retrospective cohort studies, cross-sectional studies, case control studies, randomized clinical trials (RCTs) as well as non-randomized experimental studies which addressed the review question. A systematic search was conducted in PubMed, CINAHL, Embase, Scopus, and Google Scholar to identify studies published between 1 January, 2020 and 15 August, 2021. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool was used to assess the methodological quality of studies. The analysis was done using Review Manager 5.4 and R software 4.0.2. From the total of 12 diagnostic accuracy studies with 4,817 study participants, pooled sensitivity and specificity were 78.2% and 99.5% respectively. Sensitivity was marginally higher in subgroup analysis based on studies with low risk of bias and applicability concerns (78.9%) and studies using SD Biosensor Ag-RDT (79.4%). However, an inverse relation between cycle threshold (Ct) and sensitivity of Ag-RDT was not seen. The review demonstrated pooled sensitivity value approaching the minimum performance requirement for diagnosis of COVID-19 by WHO with specificity value meeting the specified requirement. Ag-RDTs, therefore have the potential to be used as a screening tool for SARS-CoV-2 detection in low resource settings where RT-PCR might not be readily accessible. However, false negative results need to be interpreted with caution.

Introduction

Coronavirus disease 2019 (COVID-19) has been spreading rapidly across the globe causing loss of millions of lives since it was first reported in Wuhan, China and later declared a pandemic on 11th March, 2020 [1]. In addition to strategies like vaccination against COVID-19, contact tracing, and home isolation for potential exposure to or diagnosis of COVID-19, early diagnosis and community screening for COVID-19 are crucial to control the spread of disease [2]. CDC has outlined viral test (Nucleic Acid Amplification Test (NAAT) and antigen tests) and antibody tests as methods for testing current and past infection with COVID-19 respectively [3]. Although, NAAT is the preferred initial diagnostic test for COVID-19, its use in low resource settings is limited by its cost and need for qualified clinical laboratory personnel [4]. Antigen detection rapid diagnostic tests (Ag-RDTs) used for detecting SARS-CoV-2 nucleocapsid protein are inexpensive, faster and easy to use alternative of NAAT for COVID-19 testing. This trade-off for the ease-of-use of Ag-RDTs is decrease in sensitivity and specificity of test [2].

Various studies are done to evaluate the diagnostic accuracy of Ag-RDTs that vary in study design, study setting and study population along with various brands being evaluated. In a review evaluating the diagnostic accuracy of rapid point-of care antigen test for COVID-19 with studies mainly from Europe and North America, summary sensitivities were from 34.1% and 88.1% for Coris Bioconcept and SD Biosensor STANDARD Q Ag-RDTs respectively whereas overall summary specificity was 99.6% [5]. However, such study assessing the diagnostic accuracy of Ag-RDTs for study population belonging to low and middle income countries (LMIC) has not been done yet. We conducted this review to evaluate the diagnostic accuracy of Ag-RDTs, with RT-PCR as a reference standard, with study population from low and middle income countries which differ not only with the type of Ag-RDTs used but also with the testing conditions, compliance with the manufactures instruction for use, adherence to guidelines, specified method of collection and handling of specimens, etc.

Methods

Protocol and registration

We developed, conducted and reported this review following Preferred reporting items for systematic review and meta-analysis of diagnostic test accuracy studies (PRISMA-DTA) [6]. PRISMA-DTA checklist is available in S1 File. The protocol was drafted and registered before conducting the systematic review and meta-analysis in international prospective register for systematic review (PROSPERO) with registration number: CRD42021259260 which is available in S2 File.

Eligibility criteria

The eligibility criteria for studies was formulated based on population, intervention, comparator and outcome (PICO) for the review question. We included studies that evaluated the diagnostic accuracy of Ag-RDTs in terms of sensitivity and specificity, against RT-PCR as a reference standard. The study population comprised of people living in LMICs, who had undergone testing for COVID-19. Only original studies in English language published in the year 2020 and up until August 15, 2021 that described their methods and reported enough data for the construction of the standard two-by-two table were included.

We included peer reviewed prospective or retrospective cohort studies, cross-sectional studies, case control studies, randomized clinical trials as well as non-randomized experimental studies which addressed the review question. Editorials, letters to the editors, and conference abstracts were excluded since they contained insufficient information required for conducting a review. Studies in which diagnostic accuracy of Ag-RDT was determined in a sample of less than 100 was excluded so that a more reliable estimate of diagnostic accuracy could be obtained.

Index test

Ag-RDTs are designed to directly detect SARS CoV-2 viral proteins produced by the replicating virus. Most Ag-RDTs for COVID-19 use a sandwich immunodetection method employing a simple-to-use lateral flow test format with techniques such as enzyme-linked immunosorbent assay (ELISA), chromogenic based or fluorescence-based detection. In the case of SARS-CoV-2, Ag-RDTs the target analyte is often the virus’ nucleocapsid protein. After collecting the respiratory specimen and applying it to the test strip, results are read by the operator within 10 to 30 minutes with or without the aid of a reader instrument. Most of the currently manufactured tests require nasal or nasopharyngeal or oropharyngeal swab samples or bronchoalveolar lavage/ endotracheal aspirate [7, 8]. The diagnostic test accuracy of Ag-RDTs was measured in terms of sensitivity and specificity of the test to detect a SARS CoV-2 infection compared with a reference standard, RT-PCR.

Sensitivity is the percentage of cases positive by NAAT reference standard that are detected as positive by the Ag-RDTs under evaluation. Specificity is the percentage of cases negative by a NAAT reference standard that are detected as negative by the Ag-RDTs under evaluation [9].

Reference standard

Reverse transcription polymerase chain reaction (RT-PCR) for COVID-19 is a molecular test that detects the genetic material (RNA) of SARS-CoV-2 responsible for coronavirus disease. It combines the laboratory technique of reverse transcription and polymerase chain reaction which amplifies specific complementary DNA (cDNA) targets [10]. Typically samples collected from nasopharyngeal, oropharyngeal or anterior nasal swab is used. The number of amplification cycles required to reach the level of detection is reported as cycle threshold (Ct) value of RT-PCR. The fewer the Ct value, the higher the viral RNA load [4]. Among the currently available diagnostics tests for SARS-CoV-2, RT-PCR is considered a gold standard due to its improved sensitivity and specificity compared to serological methods of virus detection [11].

Search strategy

We conducted a systematic search for relevant articles in the following databases: PubMed, CINAHL, Embase, Scopus, and Google Scholar. The search strategy included keywords like "coronavirus infections", "COVID-19”, "coronavirus disease 2019", "COVID19" "SARS-CoV-2", "covid-19 testing", "Antigen based rapid diagnostic test", "diagnostic test", "lateral flow antigen", "lateral flow antigen detection", "lateral flow assay", "Point of care testing" and a list of all LMICs as listed by the World Bank in 2020 with a combination of Boolean operators [12]. We used filters such as studies published between the year 2020 and 2021 to limit the number of irrelevant articles. Furthermore, we also conducted a free hand search for relevant articles in the references section of articles included in the review to avoid missing the eligible studies. We included the studies published upto August 15, 2021. The full search strategy used in PubMed is available in S3 File.

Data screening and extraction

Our review team comprised of four members to search, extract and analyze the available data, perform risk of bias assessment and synthesis of results. Three reviewers SP, AP and DK independently screened and retrieved the studies using the search strategy and from additional sources. Studies were further reviewed for eligibility by screening titles followed by abstracts. Full-text articles of narrowed down abstracts were then be assessed for eligibility. SP and JT rechecked the decisions and upon disagreements, all four reviewers reviewed the inclusion and exclusion criteria and decision for inclusion was made based on majority’s decision. SP made the final decision after thorough reviewing when an agreement could not be reached.

Zotero, a research tool to collect, organize, and manage research publications was used to keep a record, and remove duplicates. All studies retrieved from our search strategies matching our PICO questions and inclusion criteria were imported to Zotero. Titles of the studies was first screened followed by abstracts. Screened studies were placed into appropriate subfolders created in Zotero based on decisions to include or exclude. Full text of all eligible studies were retrieved and assessed for eligibility. Final data was extracted from the included studies into an excel spreadsheet. The following information was extracted (if available): demographics details of study participants, total number of study participants, type of study, type of specimen used in Ag-RDTs and outcome measures recorded i.e. sensitivity and specificity. In case of any missing data, authors of the study were contacted for additional information. SP and AP independently extracted the data, and DK and JT checked the extracted data. Upon disagreements, all four reviewers reviewed the final extracted data, and disagreements were resolved through discussion on inclusion and exclusion criteria via majority’s decision.

Risk of bias

The Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool was used to assess the methodological quality of all studies to be included in this systematic review [13]. QUADAS-2 consists of four key domains: patient selection, index test, reference standard, and flow and timing. We assessed all the domains for risk of bias potential using different signaling questions, and the first three domains for applicability concerns. Based on this, risk of bias was judged as “low,” “high,” or “unclear”. Summary of results of QUADAS-2 for all included studies is presented in a tabular and graphical displays generated via Review manager 5.4. Two reviewers SP and JT independently assessed the risk of bias and the quality of the study. Disagreements between the authors were resolved by further discussion and consensus with other researchers.

Statistical analysis and data synthesis

We extracted data from the studies to construct standard two-by-two table used to calculate sensitivity and specificity. The studies were grouped based on a) clinical presentation at the time of testing i.e. symptomatic, asymptomatic or mixed, b) type of commercial Ag-RDT used i.e. SD Biosensor or tests other than SD Biosensor, c) Ct cut-off value for positive RT-PCR i.e. ≤40, <40, <35, <32 and non-specified, d) risk of bias and concerns regarding applicability for patient selection i.e. low or high, and e) concordance of samples used for index test and reference standard. For subgroup based on commercial Ag-RDT used, tests used in more than two studies were made a separate category (e.g. SD Biosensor) whereas those used in only one study were lumped into a common category of tests other than SD Biosensor. Likewise, subgroup analysis based on Ct cut-off value for positive RT-PCR was done only for studies where the cut-off value used in the study was clearly mentioned. A random effects model with 95% confidence interval (CI) was used to calculate pooled sensitivity and specificity using Review Manager (Revman) 5.4. Higgins’ I square was used to measure heterogeneity (I2 > 50% indicating substantial heterogeneity) [14]. Subgroup analyses were conducted in R software version 4.0.2 using R package “mada” version 0.5.8 and were predefined based on: clinical presentation at the time of testing, type of commercial Ag-RDT used, Ct cut off value for positive RT-PCR, risk of bias and concerns regarding applicability for patient selection, and concordance of samples used for index test and reference standard. Bivariate analysis was done using “reitsma” command from R package “mada” to obtain Hierarchical Summary Receiver-Operating Characteristics (HSROC) parameters, which was then used in Revman to obtain HSROC curve.

Results

Study selection and characteristics of included studies

We identified 3,064 records after performing a systematic search for articles. After removing 732 duplicate records, 2,332 studies underwent title and abstract screening. A total of 2295 studies did not address the review question and were therefore, excluded. Full text screening of remaining 37 studies yielded 12 studies which met the eligibility criteria and were included in the review. Out of the 25 excluded articles, 15 did not involve LMIC study population, four did not report all of the outcomes of interest, two had ineligible index test/reference standard, three had evaluated the diagnostic accuracy of Ag-RDT on a sample of less than 100 and one was not in English. PRISMA flow diagram for selection of studies is depicted in Fig 1.

Fig 1. PRISMA 2020 flow diagram.

Fig 1

The 12 studies included diagnostic accuracy studies were conducted in Cameroon, China, India, Mexico, Nepal, Serbia, Thailand, and Uganda which enrolled a total of 4,817 study participants. Out of the total 12 studies, 12 of them used consecutive or random sampling method as a method of patient enrollment whereas three of them used non-random method i.e. Pena-Rodriguez et al. [15]. used known cases of patients with positive RT-PCR for COVID-19 as one of the inclusion criteria, Nalumansi et al. [16] used low risk volunteer as non-case controls whereas Shrestha et al. [17] used convenience sampling method. Symptomatic patients suspected of having COVID-19 were the study population in two studies whereas another two studies used asymptomatic patients as the study population. A combination of symptomatic and asymptomatic patients were used in rest of the eight studies. Standard Q COVID-19 Ag test (SD Biosensor) was the Ag-RDT test used in majority of the studies (seven out of 12) whereas the rest of the studies used RapiGEN—BIOCREDIT COVID-19 Ag test, Coris bioconcept COVID-19 Ag respi-strip test, PathoCatch/ACCUCARE diagnostic assay, etc. Nasopharyngeal swab was used as a sample for Ag-RDT in most of the studies whereas two of the studies used nasal swab and one used a combination of nasopharyngeal and throat swab, endotracheal aspirate and sputum sample. Ct reference standard used for RT-PCR was specified in six out of twelve studies whereas the rest of the studies did not mentioned the Ct value. Table 1 summarizes the study characteristics of the included studies.

Table 1. Characteristics of included studies.

Study Study Design Study Population (age distribution) Study Location Sample type Commercial name of Ag-RDT used Clinical presentation at the time of testing Sample size (Male/Female)
Diao, 2021 [18] Prospective study Adults (16–75 years) China NPS Not available Symptomatic 251 (122/129)
Agrawal, 2021 [19] Prospective study Adults and Children (2–85 years) India NS Standard Q COVID-19 Ag test (SD Biosensor) Symptomatic and Asymptomatic 467 (239/228)
Kim, 2021 [20] Prospective & retrospective study Not Specified India NPS GenbodyCOVID-19 Ag test COVAG025 Symptomatic and Asymptomatic 200 (not specified)
Nalumansi,2020 [16] Prospective cross-sectional study Adults (31–39 years) Uganda NS Standard Q COVID-19 Ag test (SD Biosensor) Symptomatic and Asymptomatic 262 (234/28)
Boum, 2021 [21] Prospective study Adults (at least 21 years) Cameroon NPS SD Biosensor test Symptomatic and Asymptomatic 1090(not specified)
Pena-Rodriguez, 2021 [15] Prospective cross-sectional study Not Specified, Mean age: 36.6±13.16 Mexico NPS/OPS Standard Q COVID-19 Ag test (SD Biosensor) Symptomatic and Asymptomatic 369 (154/215)
Gupta, 2021 [22] Prospective cross-sectional study Adults (>18 years) India NPS Standard Q COVID-19 Ag test (SD Biosensor) Symptomatic and Asymptomatic 330 (231/99)
Chaimayo, 2020 [23] Prospective study Adults (21–72 years) Thailand NPS and TS, ETA, Sp. Standard Q COVID-19 Ag test (SD Biosensor) Symptomatic and Asymptomatic 454(not specified)
Shrestha, 2020 [17] Prospective observational study Adults and Children (13–72 years) Nepal NPS RapiGEN—BIOCREDIT COVID-19 Ag Asymptomatic 113 (24/89)
Ristic, 2021 [24] Prospective study Adults and Children (14–91 years) Serbia NPS Standard Q COVID-19 Ag test (SD Biosensor) Symptomatic 120 (63/57)
Thakur, 2021 [25] Prospective cross- sectional study Adults (18–89 years) India NPS and OPS PathoCatch/ACCUCARE Asymptomatic 677 (372/305)
Kanaujia, 2021 [26] Prospective cross-sectional study Adults and Children (13–90 years) India NPS Coris bioconcept COVID-19 ag respi-strip test Symptomatic and Asymptomatic 484 (261/223)

NPS = Nasopharyngeal Swab, NS = Nasal Swab, OPS = Oropharyngeal Swab, TS = Throat Swab, ETA = Endotracheal Aspirate, Sp. = Sputum.

Methodological quality of studies

Risk of bias on selection of patients was considered low in nine out of 12 included studies as they avoided case-control design, inappropriate exclusions of patients and non-random sampling of patients. Similarly, the included patients matched the review question in all of those studies. In contrast, the remaining three studies had high risk of bias on selection of patients along with high concerns regarding applicability as they used non-random method of patient sampling.

With regard to index test, its conduct or interpretation was considered to have low risk of bias in six studies i.e. index test was interpreted without knowledge of the reference standard and a pre-specified threshold was used. However, in remaining five studies sufficient information to clearly judge the risk of bias was not provided. In one study, index test was interpreted with knowledge of the reference standard leading to high risk of bias. Index test, its conduct or interpretation matched the review question in eight studies whereas it was unclear in remaining four studies as sufficient information was not provided regarding whether trained personnel was involved in sample collection and test administration.

Since the estimate of test accuracy is made on the assumption that the reference standard is 100% sensitive, RT-PCR alone as a reference standard, its conduct or interpretation was considered to have high risk of bias in all of the included studies as the test lacked the sensitivity of 100%. In contrast, concern regarding applicability was low for all studies except one which used real time micro PCR analyzer as a reference standard.

Under flow and timing domain, index test(s) and reference standard were collected at the same time in all of the studies. Similarly, all of the patients received the same reference standard and also were included in the analysis leading to low risk of bias with regard to patient flow. Methodological quality of included studies is presented in Figs 2 and 3.

Fig 2. Summary of risk of bias and applicability concerns for each included studies for each separate domain.

Fig 2

Fig 3. Summary of risk of bias and applicability concerns across the included studies.

Fig 3

Analysis of specific tests

Table 2 summarizes the sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), diagnostic odds ratio (DOR) along with true positive(TP), false positive(FP), true negative(TN) and false negative(FN) values for each of the Ag-RDTs used in included studies.

Table 2. Summary diagnostic accuracy data for included studies.

SN Study TP FP TN FN Sensitivity Specificity LR(+) LR(-) DOR
1 Diao,2021 152 0 50 49 0.756 1.000 - 0.244 -
2 Agrawal,2021 26 2 436 3 0.897 0.995 196.345 0.104 1889.333
3 Kim,2021 94 0 100 6 0.940 1.000 - 0.060 -
4 Nalumansi,2020 63 13 159 27 0.700 0.924 9.262 0.325 28.538
5 Boum,2021 170 54 745 121 0.584 0.932 8.644 0.446 19.383
6 Pena-Rodriguez,2021 79 0 265 25 0.760 1.000 - 0.240 -
7 Gupta,2021 63 1 252 14 0.818 0.996 207.000 0.183 1134.000
8 Chaimayo,2020 59 5 389 1 0.983 0.987 77.487 0.017 4590.200
9 Shrestha,2020 40 0 66 7 0.851 1.000 - 0.149 -
10 Ristic,2021 25 0 77 18 0.581 1.000 - 0.419 -
11 Thakur,2021 29 1 592 55 0.345 0.998 204.726 0.656 312.145
12 Kanaujia,2021 136 2 293 53 0.720 0.993 106.138 0.282 375.925

TP = True Positive, FP = False Positive, TN = True Negative, FN = False Negative, LR(+) = Positive Likelihood Ratio, LR(-) = Negative Likelihood Ratio.

A coupled forest plot of sensitivity and specificity with an ascending display of sensitivity values is shown in Fig 4 to evaluate threshold effect as a source of heterogeneity for diagnostic test accuracy study. On increasing the sensitivity values, specificity remained more or less constant thus negating the possibility of a threshold effect.

Fig 4. Coupled forest plot of sensitivity and specificity.

Fig 4

The overall pooled sensitivity and specificity of 12 Ag-RDTs was 78.2 (66.1–86.9, 95% CI) and 99.5 (98.3–99.9, 95% CI) respectively as demonstrated on Figs 5 and 6 below.

Fig 5. Pooled sensitivity of included studies.

Fig 5

Fig 6. Pooled specificity of included studies.

Fig 6

On subgroup analysis, pooled specificity was consistently higher than sensitivity and above 99% except for subgroup defined by Ct cutoff value used for positive RT-PCR (i.e. for Ct <40: 96.9% with 95% CI: 89.3–99.1%). Pooled sensitivity for subgroup analysis based on commercial type of Ag-RDT used was higher for the SD Biosensor test (i.e. 79.4% with 95% CI: 64.2–89.3%) compared to that for tests other than SD Biosensor (i.e.76.3% with 95% CI: 54.7–89.6%). Furthermore, subgroup defined by the clinical presentation at the time of testing had sensitivity ranging from 83.2% (for tests performed on either symptomatic or asymptomatic patients) to 62.9% (for tests performed on only asymptomatic patients). In addition, pooled sensitivity for subgroup based on Ct cut off value for positive RT-PCR was highest when threshold of <40 was used (91.5%) and lowest for threshold of <32 (34.5%). On the contrary, pooled sensitivity for Ct threshold of ≤40 was 69.6%. Surprisingly, pooled sensitivity values for subgroup based on sample concordance for index test and reference standard was higher for studies using different samples (81.1%) than that for those with same sample (77.7%). Pooled sensitivity was higher for tests used in studies with low risk of bias and low concerns regarding applicability for patient selection (78.9%) when compared to that for tests used in studies with high risk of bias and concerns regarding applicability (75.5%). Each of the subgroups estimating sensitivity had higher level of heterogeneity except for the subgroup defined by the risk of bias and concern regarding applicability for patient selection (i.e.I2 = 46% for high risk of bias and high concern regarding applicability). Tables 3 and 4 demonstrates the pooled sensitivity and specificity of Ag-RDTs for detection of SARS-CoV-2 on subgroup analysis.

Table 3. Pooled sensitivity of Ag-RDTs for detection of SARS-CoV-2 on subgroup analysis.

Subgroups Pooled Sensitivity (95% CI) Number of studies analyzed Total number of events Heterogeneity
I2 p-Value
Based on clinical presentation at the time of testing Symptomatic 69.6 (56.6–80.1) 2 244 81 0.02
Asymptomatic 62.9 (23.8–90.2) 2 131 96 <0.01
Symptomatic/ Asymptomatic 83.2 (70.8–91.0) 8 940 88 <0.01
Based on type of Commercial Ag-RDT used SD Biosensor test 79.4 (64.2–89.3) 7 694 94 <0.01
Other 76.3 (54.7–89.6) 5 621 85 <0.01
Based on Ct cut off value for positive RT-PCR ≤40 69.6 (56.6–80.1) 2 244 81 0.02
<40 91.5 (49.1–99.2) 2 150 90 <0.01
<35 76.0 (66.8–83.2) 1 104 NA NA
<32 34.5 (25.2–45.3) 1 84 NA NA
Not specified 82.0 (69.9–89.9) 6 733 91 <0.01
Based on risk of bias and concerns regarding applicability for patient selection Low 78.9 (62.0–89.6) 9 1074 92 <0.01
High 75.5 (68.9–81.1) 3 241 46 0.16
Based on concordance of samples used for index test and reference standard Yes 77.7 (68.2–85.0) 9 1067 86 <0.01
No 81.1 (31.6–97.5) 3 248 96 <0.01

Table 4. Pooled specificity of Ag-RDTs for detection of SARS-CoV-2 on subgroup analysis.

Subgroups Pooled Specificity (95% CI) Number of studies analyzed Total number of events Heterogeneity
I2 p-Value
Based on clinical presentation at the time of testing Symptomatic 100 (0–100) 2 127 0 1
Asymptomatic 99.8 (98.9–100) 2 659 0 1
Symptomatic/ Asymptomatic 99.1 (97.1–99.8) 8 2716 84 <0.01
Based on type of Commercial Ag-RDT used SD Biosensor test 99.1 (96.3–96.8) 7 2398 83 <0.0001
Other 99.7 (99.2–99.9) 5 1104 0 <0.01
Based on Ct cut off value for positive RT-PCR ≤40 100 (0–100) 2 127 0 1
<40 96.9 (89.3–99.1) 2 566 92 <0.01
<35 100 (0–100) 1 265 NA NA
<32 99.8 (98.8–100) 1 593 NA NA
Not specified 99.4 (97.4–99.9) 6 1951 84 <0.01
Based on risk of bias and concerns regarding applicability for patient selection Low 99.5 (98.3–99.8) 9 2999 85 <0.01
High 99.8 (62.4–100.0) 3 503 0 1
Based on concordance of samples used for index test and reference standard Yes 99.4 (97.2–99.9) 9 2250 76 <0.01
No 99.7 (98.2–99.9) 3 1252 42 0.18

HSROC curve

HSROC parameters were obtained from bivariate analysis using the reitsma function in mada package of R. Then the parameter values were added to the Revman to generate the HSROC curve. Area under the curve (AUC) was found to be 0.972. The HSROC curve is shown in Fig 7.

Fig 7. Hierarchical Summary Receiver-Operating Characteristics (HSROC) curve of the studies.

Fig 7

Discussion

This systematic review and meta-analysis on 12 studies measured the diagnostic accuracy of Ag-RDTs for study population limited to LMICs. Pooled sensitivity from all of the studies (78.2%) was lower than the minimum performance requirement specified by WHO (≥80%) whereas specificity was well above the cut-off of ≥97% (99.5%) [2]. This could be attributed to factors like study design and characteristics of participants, specimen used for Ag-RDT and RT-PCR, quality and commercial type of Ag-RDT, etc. Similar factors were highlighted in WHO interim guidance on antigen detection using rapid immunoassay for selecting Ag-RDTs for enhanced diagnostic accuracy like selection of patients, study sites, manufacturing quality and storage conditions, and clarity of instructions for use, etc [2]. In addition, diagnostic accuracy of Ag-RDT was higher among symptomatic patients than asymptomatic patients, similar to the findings of systematic reviews by Brummer et al. and Khandker et al. [27, 28]. Furthermore, higher diagnostic accuracy among symptomatic patients is further supported by the findings of a study by Kociolek et al. where asymptomatic patients were found to have a lower viral load, which is a predictor of sensitivity, than symptomatic patients [29]. Although studies have reported an inverse correlation between sensitivity of Ag-RDTs and Ct value, such finding was not observed in this review [28].

This review was conducted to bridge the research gap with regard to diagnostic accuracy of Ag-RDTs for diagnosis of SARS-CoV-2 in LMIC. Khandker et al. in their review of diagnostic accuracy of rapid antigen test kits reported the sensitivity of rapid antigen test to be higher in population of Europe and America as compared to that in Asia and Africa i.e. low resource settings. The finding was attributed to the repetitive freeze-thaw process during transportation owing to lack of in-situ manufacture of kits in Asia and Africa in most instances [28]. However, the diagnostic accuracy of SD Biosensor Ag-RDT, the most commonly used test among included studies in the review, was fairly high (Sensitivity:79.4%, Specificity:99.1%) and approaching the minimum WHO performance requirement [2].

The main strength of this study lies in its comprehensive approach to review the available evidence on diagnostic accuracy of Ag-RDTs and provide some of the earliest reported evidence on their diagnostic accuracy with a study population narrowed to people living in LMIC. Furthermore, we only included peer reviewed published articles in the review to avoid skewing of the results by the studies from non-peer reviewed studies. Similarly, we followed rigorous methods for accurate risk of bias assessment along with screening for articles, study selection and data extraction.

The main limitations of this review is the methodological quality of the included studies. Three of the twelve studies used non-random method of patient selection whereas Ct threshold for RT-PCR was specified in only six out of 12 studies. Since, Ct threshold is an indirect measure of viral load of the specimen, assessing the diagnostic accuracy without its knowledge limits the comparability of the studies [30]. Furthermore, the risk of bias for the domain reference standard was high in all of the included studies as RT-PCR itself does not has an accuracy of 100% and a more comprehensive assessment with a combination of parameters should be set as a reference standard to access the diagnostic accuracy of Ag-RDTs. Interpretation of findings of subgroup analysis must be done taking into account the higher level of heterogeneity for all of the subgroups except that for the one based on risk of bias and concern regarding applicability for patient selection with low level of heterogeneity.

Despite the limitations of the study, this review provides a fresh and a unique perspective on diagnostic accuracy of Ag-RDTs in LMICs which has a significant public health implication in regards to the widespread use of Ag-RDTs over RT-PCR for COVID-19 testing. Diagnostic accuracy of Ag-RDTs approaching the near recommended performance requirement specified by WHO provides an evidence based rationale behind the use of Ag-RDT to address the diagnostic challenge for COVID-19 in LMICs. However, further studies to evaluate diagnostic accuracy of Ag-RDT using reference standard with near 100% diagnostic accuracy, achieved via combination of clinical, imaging and laboratory tests, to measure a true disease status, should be conducted to measure the true test accuracy. In addition, diagnostic test accuracy of Ag-RDTs should be evaluated under variable testing conditions i.e. test accuracy using different samples for Ag-RDT, test performed in different days of symptom onset, tests performed in various age groups, etc. The evidence thus generated could be used to evaluate the test accuracy in further detail which could therefore guide clinical use of Ag-RDT as well as direct scientific community to generate testing algorithms for COVID-19 using Ag-RDTs in settings where RT-PCR might not be readily accessible.

Conclusions

The review on diagnostic accuracy of Ag-RDTs with studies only from low and middle income countries demonstrated pooled sensitivity value approaching the minimum performance requirement for diagnosis of COVID-19 by WHO with specificity value meeting the specified requirement. Ag-RDTs therefore, have the potential to be used as a screening tool for SARS-CoV-2 detection in low resource settings where RT-PCR might not be readily accessible. However, caution should be exercised over interpretation of negative results owing to the lower sensitivity of Ag-RDTs.

Supporting information

S1 File. PRISMA-DTA checklist.

(PDF)

S2 File. Study protocol registered in PROSPERO.

(PDF)

S3 File. Search strategy in PubMed.

(DOCX)

Acknowledgments

We would like to acknowledge Dr. Rolina Dhital, Dr. Richa Shah and Dr. Carmina Shrestha along with the whole team of Health Action and Research for their continued guidance and support while conducting the research. We would also like to acknowledge Dr. Amrit Devkota, Dr. Ujwal Raut, Dr. Anuradha Raut, and Dr. Chet Bahadur Ranabhat for their contribution to the research.

Data Availability

All relevant data are within the paper and its Supporting information files.

Funding Statement

The author(s) received no specific funding for this work.

References

  • 1.World Health Organization. WHO Director-General’s opening remarks at the media briefing on COVID-19–11 March 2020. 2020 [cited 3 Mar 2022]. https://www.who.int/director-general/speeches/detail/who-director-general-s-opening-remarks-at-the-media-briefing-on-covid-19---11-march-2020
  • 2.World Health Organization. Antigen-detection in the diagnosis of SARS-CoV-2 infection using rapid immunoassays. Geneva: World Health Organization; 2020. p. 9. https://www.who.int/publications-detail-redirect/antigen-detection-in-the-diagnosis-of-sars-cov-2infection-using-rapid-immunoassays [Google Scholar]
  • 3.United States Centers for Disease Control and Prevention. COVID-19 Testing: What You Need To Know. 2021 [cited 18 Sep 2021]. https://www.cdc.gov/coronavirus/2019-ncov/symptoms-testing/testing.html
  • 4.Afzal A. Molecular diagnostic technologies for COVID-19: Limitations and challenges. J Adv Res. 2020;26: 149–159. doi: 10.1016/j.jare.2020.08.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Dinnes J, Deeks JJ, Berhane S, Taylor M, Adriano A, Davenport C, et al. Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst Rev. 2021;3: CD013705. doi: 10.1002/14651858.CD013705.pub2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.McInnes MDF, Moher D, Thombs BD, McGrath TA, Bossuyt PM, and the PRISMA-DTA Group. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement. JAMA. 2018;319: 388–396. doi: 10.1001/jama.2017.19163 [DOI] [PubMed] [Google Scholar]
  • 7.World Health Organization. SARS-CoV-2 antigen-detecting rapid diagnostic tests: An implementation guide. Geneva: World Health Organization; 2020. p. 45. https://www.who.int/publications-detail-redirect/9789240017740 [Google Scholar]
  • 8.D’Cruz RJ, Currier AW, Sampson VB. Laboratory Testing Methods for Novel Severe Acute Respiratory Syndrome-Coronavirus-2 (SARS-CoV-2). Front Cell Dev Biol. 2020;8: 468. doi: 10.3389/fcell.2020.00468 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Swift A, Heale R, Twycross A. What are sensitivity and specificity? Evid Based Nurs. 2020;23: 2–4. doi: 10.1136/ebnurs-2019-103225 [DOI] [PubMed] [Google Scholar]
  • 10.Freeman WM, Walker SJ, Vrana KE. Quantitative RT-PCR: pitfalls and potential. BioTechniques. 1999;26: 112–122, 124–125. doi: 10.2144/99261rv01 [DOI] [PubMed] [Google Scholar]
  • 11.Kevadiya BD, Machhi J, Herskovitz J, Oleynikov MD, Blomberg WR, Bajwa N, et al. Diagnostics for SARS-CoV-2 infections. Nat Mater. 2021;20: 593–605. doi: 10.1038/s41563-020-00906-z [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.The World Bank Group. World Bank Country and Lending Groups. 2021 [cited 28 Sep 2021]. https://datahelpdesk.worldbank.org/knowledgebase/articles/906519-world-bank-country-and-lending-groups.
  • 13.Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155: 529–536. doi: 10.7326/0003-4819-155-8-201110180-00009 [DOI] [PubMed] [Google Scholar]
  • 14.Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, et al., editors. Cochrane handbook for systematic reviews of interventions version 6.3 (updated February 2022). Cochrane; 2022. https://training.cochrane.org/handbook [Google Scholar]
  • 15.Peña-Rodríguez M, Viera-Segura O, García-Chagollán M, Zepeda-Nuño JS, Muñoz-Valle JF, Mora-Mora J, et al. Performance evaluation of a lateral flow assay for nasopharyngeal antigen detection for SARS-CoV-2 diagnosis. J Clin Lab Anal. 2021;35: e23745. doi: 10.1002/jcla.23745 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Nalumansi A, Lutalo T, Kayiwa J, Watera C, Balinandi S, Kiconco J, et al. Field evaluation of the performance of a SARS-CoV-2 antigen rapid diagnostic test in Uganda using nasopharyngeal samples. Int J Infect Dis IJID Off Publ Int Soc Infect Dis. 2021;104: 282–286. doi: 10.1016/j.ijid.2020.10.073 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Shrestha B, Neupane AK, Pant S, Shrestha A, Bastola A, Rajbhandari B, et al. Sensitivity and Specificity of Lateral Flow Antigen Test Kits for COVID-19 in Asymptomatic Population of Quarantine Centre of Province 3. Kathmandu Univ Med J KUMJ. 2020;18: 36–39. [PubMed] [Google Scholar]
  • 18.Diao B, Wen K, Zhang J, Chen J, Han C, Chen Y, et al. Accuracy of a nucleocapsid protein antigen rapid test in the diagnosis of SARS-CoV-2 infection. Clin Microbiol Infect Off Publ Eur Soc Clin Microbiol Infect Dis. 2021;27: 289.e1–289.e4. doi: 10.1016/j.cmi.2020.09.057 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Agarwal J, Das A, Pandey P, Sen M, Garg J. “David vs. Goliath”: A simple antigen detection test with potential to change diagnostic strategy for SARS-CoV-2. J Infect Dev Ctries. 2021;15: 904–909. doi: 10.3855/jidc.13925 [DOI] [PubMed] [Google Scholar]
  • 20.Kim D, Lee J, Bal J, Seo SK, Chong C-K, Lee JH, et al. Development and Clinical Evaluation of an Immunochromatography-Based Rapid Antigen Test (GenBody COVAG025) for COVID-19 Diagnosis. Viruses. 2021;13: 796. doi: 10.3390/v13050796 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Boum Y, Fai KN, Nicolay B, Mboringong AB, Bebell LM, Ndifon M, et al. Performance and operational feasibility of antigen and antibody rapid diagnostic tests for COVID-19 in symptomatic and asymptomatic patients in Cameroon: a clinical, prospective, diagnostic accuracy study. Lancet Infect Dis. 2021;21: 1089–1096. doi: 10.1016/S1473-3099(21)00132-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Gupta A, Khurana S, Das R, Srigyan D, Singh A, Mittal A, et al. Rapid chromatographic immunoassay-based evaluation of COVID-19: A cross-sectional, diagnostic test accuracy study & its implications for COVID-19 management in India. Indian J Med Res. 2020;153: 126–31. doi: 10.4103/ijmr.IJMR_3305_20 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Chaimayo C, Kaewnaphan B, Tanlieng N, Athipanyasilp N, Sirijatuphat R, Chayakulkeeree M, et al. Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand. Virol J. 2020;17: 177. doi: 10.1186/s12985-020-01452-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Ristić M, Nikolić N, Čabarkapa V, Turkulov V, Petrović V. Validation of the STANDARD Q COVID-19 antigen test in Vojvodina, Serbia. PloS One. 2021;16: e0247606. doi: 10.1371/journal.pone.0247606 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Thakur P, Saxena S, Manchanda V, Rana N, Goel R, Arora R. Utility of Antigen-Based Rapid Diagnostic Test for Detection of SARS-CoV-2 Virus in Routine Hospital Settings. Lab Med. 2021;52: e154–e158. doi: 10.1093/labmed/lmab033 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Kanaujia R, Ghosh A, Mohindra R, Singla V, Goyal K, Gudisa R, et al. Rapid antigen detection kit for the diagnosis of SARS-CoV-2—are we missing asymptomatic patients? Indian J Med Microbiol. 2021;S0255-0857: 04168–2. doi: 10.1016/j.ijmmb.2021.07.003 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Brümmer LE, Katzenschlager S, Gaeddert M, Erdmann C, Schmitz S, Bota M, et al. Accuracy of novel antigen rapid diagnostics for SARS-CoV-2: A living systematic review and meta-analysis. PLOS Med. 2021;18: e1003735. doi: 10.1371/journal.pmed.1003735 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Khandker SS, Nik Hashim NHH, Deris ZZ, Shueb RH, Islam MA. Diagnostic Accuracy of Rapid Antigen Test Kits for Detecting SARS-CoV-2: A Systematic Review and Meta-Analysis of 17,171 Suspected COVID-19 Patients. J Clin Med. 2021;10: 3493. doi: 10.3390/jcm10163493 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Kociolek LK, Muller WJ, Yee R, Dien Bard J, Brown CA, Revell PA, et al. Comparison of Upper Respiratory Viral Load Distributions in Asymptomatic and Symptomatic Children Diagnosed with SARS-CoV-2 Infection in Pediatric Hospital Testing Programs. J Clin Microbiol. 2020;59: e02593–20. doi: 10.1128/JCM.02593-20 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Rao SN, Manissero D, Steele VR, Pareja J. A Systematic Review of the Clinical Utility of Cycle Threshold Values in the Context of COVID-19. Infect Dis Ther. 2020;9: 573–586. doi: 10.1007/s40121-020-00324-3 [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

S1 File. PRISMA-DTA checklist.

(PDF)

S2 File. Study protocol registered in PROSPERO.

(PDF)

S3 File. Search strategy in PubMed.

(DOCX)

Data Availability Statement

All relevant data are within the paper and its Supporting information files.


Articles from PLOS Global Public Health are provided here courtesy of PLOS

RESOURCES