Abstract
Plasma membrane tension functions as a global physical organizer of cellular activities. Technical limitations of current membrane tension measurement techniques have hampered in-depth investigation of cellular membrane biophysics and the role of plasma membrane tension in regulating cellular processes. Here, we develop an optical membrane tension reporter by repurposing an E. coli mechanosensitive channel via insertion of circularly permuted GFP (cpGFP), which undergoes a large conformational rearrangement associated with channel activation and thus fluorescence intensity changes under increased membrane tension.
Keywords: membrane tension, reporter, mechanosensitive channel, protein engineering, cell mechanics
Graphical Abstract
The plasma membrane is the initial medium through which a cell detects and reacts to external physical stimuli. As a global mechanical regulator, plasma membrane tension coordinates a number of cellular behaviors1–3. For instance, membrane tension governs the homeostasis between exocytosis and endocytosis, where high membrane tension promotes exocytosis while low membrane tension supports endocytosis by enhancing vesicle trafficking4,5. In addition, actin-based protrusions have also been suggested to be regulated by plasma membrane tension wherein low membrane tension facilitates polymerization of actin filaments, which generates lamellipodium-like protrusions at the leading edge during cell spreading6. Moreover, plasma membrane coordinates cytoskeletal tension for force transmission to control cell polarity and movement7.
Although membrane tension has been shown to play critical roles in regulating cell behaviors, the molecular mechanisms by which cells actively regulate membrane tension remain largely unknown. Studies have shown that certain membrane proteins can sense extracellular mechanical forces and convert them into intracellular biochemical signals dubbed as mechanotransduction to modulate cell activities. For example, changes in membrane tension can be recognized and be affected by the activity of membrane-to-cortex proteins, which act as a linker between cellular membranes and actin filaments8. Mechanosensitive (MS) channels are another membrane tension sensor with their channel pore opening controlled by changes in plasma membrane tension9. Found in all bacteria, mechanosensitive channel of large conductance (MscL) is one of the most studied non-selective MS channels for transporting molecules and ions across the membrane in response to physical stimuli10. It is also believed to function as a pressure regulator to prevent lysis of bacterial membrane resulting from the sudden increase of membrane tension during osmotic down-shock11. Other eukaryotic MS proteins such as transient receptor potential (TRP) channels12 and Piezo113 are found to mediate a variety of sensations including hearing, touch, and thermo- and osmo-sensation.
Despite the above-mentioned proteins identified as natural membrane tension sensors, a lack of suitable membrane tension measurement tools has hindered detailed studies of the effect of membrane tension on cellular processes. Therefore, development of molecular sensors that report membrane tension of live cells is of significant interest. One of the most widely used technologies for membrane tension quantification is micropipette aspiration14, in which surface tension is deduced by measured radius of pipette and cells subjected to suction pressure applied by the micropipette using the Laplace law. The use of optical tweezers15 or atomic force microscopy16 is another option for indirect membrane tension measurement. However, these methods require special technical expertise and instrumentation. In recent years, several new methods have been developed to measure molecular tension. The development of fluorescence resonance energy transfer (FRET)-based biosensors has revolutionized the imaging of molecular signals with high spatiotemporal resolution17,18. However, the limitations in sensitivity and specificity have hindered their broader applications. In addition, current FRET-based tension biosensors focus on the tension change in the actin cytoskeleton or focal adhesion proteins rather than plasma membrane tension19. Although fluorescent membrane tension probes using small molecules such as Laurdan and Flipper-TR have been used in the past few years20,21, their functions and sensitivities are highly dependent on lipid and chemical environment. To overcome above-mentioned technical barriers, herein we report the development of an optical membrane tension reporter using genetically modified MscL. Given that MscL opens a pore in response to elevated membrane tension, our membrane tension reporter acts both as a sensor and as an actuator.
Specifically, our approach involves the development of a membrane tension OFF sensor, by inserting circularly permuted green fluorescence protein (cpGFP), whose optical property depends on its structure, into the extracellular domain of MscL G22S. As a gain-of-function mutant of MscL, MscL G22S has a ~50% lower tension activation threshold (5–6 mN/m) compared to wild type (WT) MscL22. MscL G22S is used instead of WT MscL given the increased sensitivity to mechanical stimuli. An increase in membrane tension causes the tilting of MscL G22S’s transmembrane helices and triggers channel opening. Since MscL is activated solely by increased membrane tension, a MscL conformation reporter is a proxy for reporting relative membrane tension increases. We hypothesize that structural rearrangement of MscL G22S caused by membrane tension would be transferred to the connected cpGFP, leading to a conformational change that gives rise to a change in its fluorescence (Figure 1A). A similar concept has been recently utilized for the successful development of a fluorescent voltage sensor23.
To generate the membrane tension reporter DNA construct, we first encoded MscL G22S with cpGFP fused to its extracellular loop domain after amino acid 61 into a plasmid vector, under the control of CMV promoter as version 1 (Figure 1B). However, transfection of NIH3T3 cells leads to expression of the reporter version 1 and their notable intracellular accumulation but poor membrane localization (Figure 1C). We speculate a lack of a mammalian-specific export signal, which inhibits heterologous protein retention in the endoplasmic reticulum (ER), is responsible for MscL cytoplasmic accumulation. To overcome this, we next appended Kir2.1 ER export signal (FCYENEV), which is known to mediate protein export from ER to Golgi complex to plasma membrane24, to the C terminus of MscL G22S as version 2 (Figure 1B). This strategy has previously been shown to promote MscL membrane expression in neurons25. To examine localization of the MscL tension reporters, we co-transfected cells with either reporter design along with a membrane-targeted HaloTag construct (TMD-Halo), where HaloTag was linked to the transmembrane domain of transferrin receptor (TfR) for membrane localization.
As shown in Figure 1C, reduction of cytoplasmic aggregation and enhancement of membrane expression of version 2 reporter was confirmed by stronger cpGFP signal observed in plasma membrane targeted with TMD-Halo as compared to that of version 1 reporter. Version 2 reporter (MscL(G22S)61-cpGFP) is referred to as MscL tension reporter and used for the remainder experiments.
To test MscL tension reporter sensitivity, we applied an osmotic pressure test, with increasing osmotic shock to cells transfected with the MscL tension reporter. Hypo-osmotic condition is a well-accepted means to increase membrane tension. Previously, we have shown influx of small molecules into mammalian cells expressing MscL in an osmotic pressure dependent manner26,27. In the osmotic pressure test, the osmolarity of culture medium was gradually decreased from 330 to 108 mOsm. As shown in Figure 2Ai, MscL tension reporters were found on the membrane as indicated by TMD-Halo in NIH3T3 cells over the range of hypo-osmotic conditions. MscL(G22S)61-cpGFP fluorescence decreased as the osmolarity of culture medium decreased, supporting that the MscL tension reporters function properly in living cells.
To verify that the declining fluorescence intensity in Figure 2Ai was not caused mainly by photobleaching, we fused GFP to the C-terminus of MscL G22S as a control (MscL(G22S)-c-term-GFP) and carried out the same osmotic pressure test. While the membrane localization of the control sensor was similar to that of the MscL tension reporter, no significant change of the green fluorescence intensity at the plasma membrane was detected as the osmolarity of culture medium decreased (Figure 2Aii). We analyzed the fluorescence intensity by normalizing the fluorescence with the initial fluorescence intensity localized to the plasma membranes (using a mask generated from the TMD-Halo image) of cells under iso-osmotic condition (Figure S1). Cells with MscL tension reporters displayed a substantial decrease in fluorescence in response to increasing osmotic pressure. For example, osmotic pressure with an osmolarity difference of 220 mOsm reduced fluorescence intensity by about 23%, whereas cells expressing the control sensors manifested only 5% fluorescence reductions under the same osmolarity difference (Figure 2B). This is also evident from normalized fluorescence of MscL tension reporters in individual cells for both conditions (Figure 2C). Besides MscL(G22S)-c-term-GFP, we also generated three other controls. The first construct is GFP-P2A-MscL(G22S), in which we used a bicistronic construct with self-cleaving peptide P2A to express MscL G22S and GFP. To rule out the influence of different environmental sensitivity and photostability between GFP and cpGFP on fluorescence change in response to osmolarity, we created another control MscL G22S-c-term-cpGFP, where cpGFP is fused to the C-terminus of MscL G22S. In addition, we also inserted cpGFP into the extracellular domain after amino acid 70 of a glutamine transporter GluR0, an ion channel which is not mechanosensitive, as Glu70-cpGFP. With all three control constructs, we found that GFP/cpGFP fluorescence at the membrane (GFP-P2A-MscL(G22S), MscL(G22S)-c-term-cpGFP and Glu70-cpGFP) did not reduce with increasing osmolarity difference (Figure S2–S4), suggesting that volume changes of cells due to osmotic downshock did not appreciably change fluorescence of these control constructs at the membrane.
Besides testing hypotonic conditions, we also applied increasing hyper-osmotic shocks to cells by adding different amount of 10X PBS to the cell culture medium and found that no appreciable cpGFP membrane fluorescence changes were observed during the test (Figure S5), consistent with the fact that hypertonic state does not change the protein structure of MscL, and MscL remains closed under hyper-osmotic conditions as in iso-osmotic condition.
To further verify the sensitivity of fluorescence shift of the MscL tension reporter in response to changes in membrane tension, we performed cyclic osmotic test on NIH3T3 cells co-transfected with MscL tension reporter and TMD-Halo. The osmolarity was repeatedly switched between iso-osmotic (~330 mOsm) and hypo-osmotic conditions (~165 mOsm) to generate alternating ‘resting’ and elevated membrane tension. As shown in Figure 3A, MscL tension reporter was located on plasma membrane as expected. MscL(G22S)61-cpGFP fluorescence intensity varied depending on membrane tensions resulting from the cyclic iso-osmotic and hypo-osmotic conditions. We observed an alternating pattern of high and low fluorescence in iso-osmotic and hypo-osmotic conditions, respectively.
When quantified as before, fluorescence intensities of the MscL tension reporter displayed a ‘W’ shape trend (Figure 3B, Ci). A similar cyclical test was also conducted on NIH 3T3 cells transfected with MscL-(G22S)-c-term-GFP as a control, in which no obvious trend of MscL fluorescence could be correlated to the osmolarity changes (Figure 3Aii, B, Cii). Our other controls GFP-P2A-MscL(G22S), MscL(G22S)-c-term-cpGFP and Glu70-cpGFP also lacked such a trend (Figure S6–S8). Together, these results demonstrate the reversibility of the MscL tension reporter.
All our osmotic shock measurements so far have been conducted at 4 min after the onsets of osmotic shocks. Nonetheless, it is well appreciated that cells have the ability to accommodate and recover from rapid changes in cell volume during osmotic shocks to regulate membrane tension28. Therefore, we sought to correlate the cell recovery dynamics from osmotic shocks to the corresponding membrane fluorescence of the MscL tension reporter. We performed cell volume measurements every 1 min after hypo-osmotic shocks (with ~165 mOsm osmotic difference between cells and medium) in the first 5 min and continue tracking at 10 min, 20 min and 30 min, respectively, by using 3D reconstruction of side view of cells analyzed with Limeseg (Figure 4A). In separate experiments we acquired MscL tension reporter fluorescence under the same condition. We observed significant increase in cell volume (~61%) and decrease in tension reporter fluorescence (~21%) in the first 2 min after exposure of cells to hypotonic medium, which is followed by gradual decrease in the average cell volume from 2 to 10 min. During this same period, the corresponding fluorescence of the tension reporter increased from 2 to 10 min (Figure 4B), showing a positive correlation between cell volume and membrane tension changes during the dynamic cell recovery under hypotonic condition.
Finally, we used polydimethylsiloxane (PDMS) micropost arrays to further demonstrate the applicability of the MscL membrane tension sensor in cells under different spreading conditions. Micropost array technologies have been widely used to study the mechanosensitive behaviors of cells. Cells attached to fibronectin-coated microposts with different post heights, therefore stiffnesses, experience different degrees of cell spreading29–31. Cells attached to shorter microposts have greater membrane tension as they spread more on more rigid substrates. Conversely, longer microposts cause lower plasma membrane tension due to limited cell spreading on softer substrates. For our assay, fibronectin (50 μg/mL) was microcontact printed onto micropost arrays to create an adhesive surface. Human mesenchymal stem cells (hMSCs) co-transfected with the MscL tension reporter and TMD-Halo were seeded at a density of around 1,500 cells/cm2 on micropost arrays with posts of 1.83 μm diameter and 2.3 or 6.4 μm height. We observed successful expression and membrane localization of the MscL tension reporter, and cells seeded on short microposts exhibited lower cpGFP membrane fluorescence in compared to those attached to longer microposts (Figure 5A), consistent with the data from the osmotic pressure experiments in Figure 2Ai. We should note that cells were transfected prior to seeding them on short vs. long microposts, so differences in membrane tension reporter fluorescence intensity in cells on short vs. long microposts could not have resulted from different expression levels. As expected, cells spread more on short microposts compared to long microposts, irrespective of the constructs expressed (Figure 5B).
While cells expressing the MscL tension sensor responded to changes in cell spreading, with ~33% reduction in average of membrane fluorescent intensity from longer to shorter microposts, the control MscL(G22S)-c-term-GFP expressing cells showed no difference in GFP membrane fluorescence under the same conditions (Figure 5C).
Our study demonstrates that the MscL tension reporter can be expressed efficiently on cell membranes and used in different cell types for membrane tension measurement. However, one drawback is the limitation that the reporter only measures membrane tension in hypotonic conditions due to intact MscL structure under iso- and hypertonic conditions. Another potential concern is that MscL expression may exert major physiological effects on the cells and alter innate cell membrane tension and volume regulation, given MscL’s large opening. To what extent MscL opening regulates membrane tension is debatable and remains to be tested. In bacteria, MscL serves as an emergency release valve for tensional homeostasis. Bacteria have significantly higher surface area to volume ratio compared to mammalian cells, so it is not apparent to what degree MscL opening alters membrane tension in mammalian cells. Previously, our lab has expressed MscL in mammalian cells and introduced membrane impermeable small molecules into cells following a 2 to 3-min hypo-osmotic shock26. We did not find MscL expression and activation had an adverse effect on cell viability. In another more recent work, we examined migration of MscL expressing cells in confining microfluidic channels and found that migration velocity was not affected once they entered the microfluidic channel, but MscL expressing cells were stuck more at the entrance compared to control cells27. Nevertheless, the effect of MscL activation on cell physiology should be further examined to ensure the use of the reporter does not adversely impact cell physiology. As alluded earlier, our MscL tension reporter is both a tension sensor and an actuator since its opening can lead to upregulated transmembrane transport. In this context, it is perhaps worth speculating that the cpGFP inserted into the extracellular loop may reduce MscL conductance. Finally, it will be desirable to perform detailed analysis of membrane tension and fluorescence from the reporter. Membrane tension response to hypo-osmotic shock likely varies significantly across cell types and such calibration, in each experimental system, would be necessary for quantitative assessment of membrane tension and would be the subject of future research. Given our goal was to establish a membrane tension reporter based on MscL, we believe our current data support the use of this reporter.
In summary, we successfully developed an optical membrane tension reporter by repurposing MscL through insertion of cpGFP. As an OFF sensor, fluorescence of the MscL tension reporter is negatively correlated to membrane tension. The MscL membrane tension reporter is user friendly, thus offering a useful approach for detailed investigations of spatial and temporal dynamics of membrane tension, which will help advance research in cell mechanics, mechanotransduction, and cell signaling in a variety of cell types (e.g., mammalian, plant, and archaea) and subcellular organellar membranes including the membranes of the nucleus and the endoplasmic reticulum.
Supplementary Material
ACKNOWLEDGMENT
A construct with HaloTag-encapsulin was a kind gift from Tobias Giessen at the University of Michigan. We thank Taekjip Ha (Johns Hopkins University) for providing the pDisplay-SpyCatcher plasmid that contains TfR transmembrane domain. We thank Robin Zhexuan Yan for helping with micropost array device fabrication. We thank Damon Hoff from the Single Molecule Analysis in Real Time Center at the University of Michigan for technical assistance. This work is supported by the National Institutes of Health (R21 GM134167 and R01 EB030031). A.M.R.I. is partially supported by the Univ. Michigan Rackham Predoctoral Fellowship.
Footnotes
Supporting Information The Supporting Information is available free of charge on the ACS Publications website.
Experimental details, micropost array fabrication, additional results, including figures and tables, data analysis and image processing (PDF)
REFERENCES
- (1).Diz-Muñoz A; Fletcher DA; Weiner OD Use the Force: Membrane Tension as an Organizer of Cell Shape and Motility. Trends in Cell Biology. 2013, 23 (2), 47–53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (2).Masters TA; Pontes B; Viasnoff V; Li Y; Gauthier NC Plasma Membrane Tension Orchestrates Membrane Trafficking, Cytoskeletal Remodeling, and Biochemical Signaling during Phagocytosis. Proc Natl Acad Sci U S A 2013, 110 (29), 11875–11880. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (3).Shi Z; Graber ZT; Baumgart T; Stone HA; Cohen AE Cell Membranes Resist Flow. Cell 2018, 175 (7), 1769–1779. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (4).Gauthier NC; Fardin MA; Roca-Cusachs P; Sheetz MP Temporary Increase in Plasma Membrane Tension Coordinates the Activation of Exocytosis and Contraction during Cell Spreading. Proc Natl Acad Sci U S A 2011, 108 (35), 14467–14472. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (5).Joseph JG; Liu AP Mechanical Regulation of Endocytosis: New Insights and Recent Advances. Adv Biosyst 2020, 4 (5), 1900278. [DOI] [PubMed] [Google Scholar]
- (6).Raucher D; Sheetz MP Cell Spreading and Lamellipodial Extension Rate Is Regulated by Membrane Tension. Journal of Cell Biology 2000, 148 (1), 127–136. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (7).Houk AR; Jilkine A; Mejean CO; Boltyanskiy R; Dufresne ER; Angenent SB; Altschuler SJ; Wu LF; Weiner OD Membrane Tension Maintains Cell Polarity by Confining Signals to the Leading Edge during Neutrophil Migration. Cell 2012, 148 (1–2), 175–188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (8).Nambiar R; McConnell RE; Tyska MJ Control of Cell Membrane Tension by Myosin-I. Proc Natl Acad Sci U S A 2009, 106 (29), 11972–11977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (9).Martinac B Mechanosensitive Ion Channels: Molecules of Mechanotransduction. J Cell Sci 2004, 117 (12), 2449–2460. [DOI] [PubMed] [Google Scholar]
- (10).Perozo E; Cortes DM; Sompornpisut P; Kloda A; Martinac B Open Channel Structure of MscL and the Gating Mechanism of Mechanosensitive Channels. Nature 2002, 418 (6901), 942–948. [DOI] [PubMed] [Google Scholar]
- (11).Levina N; Tötemeyer S; Stokes NR; Louis P; Jones MA; Booth IR Protection of Escherichia Coli Cells against Extreme Turgor by Activation of MscS and MscL Mechanosensitive Channels: Identification of Genes Required for MscS Activity. EMBO Journal 1999, 18 (7), 1730–1737. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (12).Patel A; Sharif-Naeini R; Folgering JRH; Bichet D; Duprat F; Honoré E Canonical TRP Channels and Mechanotransduction: From Physiology to Disease States. Pflugers Archiv European Journal of Physiology. 2010, 460, 571–581. [DOI] [PubMed] [Google Scholar]
- (13).Ridone P; Vassalli M; Martinac B Piezo1 Mechanosensitive Channels: What Are They and Why Are They Important. Biophysical Reviews. 2019, 11, 795–805. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (14).Hochmuth RM Micropipette Aspiration of Living Cells. Journal of Biomechanics. 2000, 33(1), 15–22. [DOI] [PubMed] [Google Scholar]
- (15).Nussenzveig HM Cell Membrane Biophysics with Optical Tweezers. European Biophysics Journal 2018, 47 (5), 499–514. [DOI] [PubMed] [Google Scholar]
- (16).Kirmizis D; Logothetidis S Atomic Force Microscopy Probing in the Measurement of Cell Mechanics. International Journal of Nanomedicine. 2010, 5, 137–145 [DOI] [PMC free article] [PubMed] [Google Scholar]
- (17).Wang Y; Wang N FRET and Mechanobiology. Integrative Biology. 2009, 1, 565–573. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (18).Liu L; He F; Yu Y; Wang Y Application of FRET Biosensors in Mechanobiology and Mechanopharmacological Screening. Frontiers in Bioengineering and Biotechnology. 2020, 8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (19).Cost AL; Ringer P; Chrostek-Grashoff A; Grashoff C How to Measure Molecular Forces in Cells: A Guide to Evaluating Genetically-Encoded FRET-Based Tension Sensors. Cell Mol Bioeng 2015, 8 (1), 96–105. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (20).Boyd MA; Kamat NP Visualizing Tension and Growth in Model Membranes Using Optical Dyes. Biophys J 2018, 115, 1307–1315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (21).Colom A; Derivery E; Soleimanpour S; Tomba C; Molin MD; Sakai N; González-Gaitán M; Matile S; Roux A A Fluorescent Membrane Tension Probe. Nat Chem 2018, 10, 1118–1125. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (22).Rosholm KR; Baker MAB; Ridone P; Nakayama Y; Rohde PR; Cuello LG; Lee LK; Martinac B Activation of the Mechanosensitive Ion Channel MscL by Mechanical Stimulation of Supported Droplet-Hydrogel Bilayers. Sci Rep 2017, 7 (1), 1–10. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (23).St-Pierre F; Marshall JD; Yang Y; Gong Y; Schnitzer MJ; Lin MZ High-Fidelity Optical Reporting of Neuronal Electrical Activity with an Ultrafast Fluorescent Voltage Sensor. Nat Neurosci 2014, 17 (6), 884–889. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (24).Hofherr A; Fakler B; Klöcker N Selective Golgi Export of Kir2.1 Controls the Stoichiometry of Functional Kir2.x Channel Heteromers. J Cell Sci 2005, 118 (9), 1935–1943. [DOI] [PubMed] [Google Scholar]
- (25).Soloperto A; Boccaccio A; Contestabile A; Moroni M; Hallinan GI; Palazzolo G; Chad J; Deinhardt K; Carugo D; Difato F Mechano-Sensitization of Mammalian Neuronal Networks through Expression of the Bacterial Large-Conductance Mechanosensitive Ion Channel. J Cell Sci 2018, 131 (5), 210393. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (26).Heureaux J; Chen D; Murray VL; Deng CX; Liu AP Activation of a Bacterial Mechanosensitive Channel in Mammalian Cells by Cytoskeletal Stress. Cell Mol Bioeng 2014, 7 (3), 307–319. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (27).Heureaux-Torres J; Luker KE; Haley H; Pirone M; Lee LM; Herrera Y; Luker GD; Liu AP The Effect of Mechanosensitive Channel MscL Expression in Cancer Cells on 3D Confined Migration. APL Bioeng 2018, 2 (3), 032001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (28).Gonzalez NP; Tao J; Rochman ND; Vig D; Chiu E; Wirtz D; Sun SX Cell Tension and Mechanical Regulation of Cell Volume. Mol Biol Cell 2018, 29, 2591–2600. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (29).Fu J; Wang YK; Yang MT; Desai RA; Yu X; Liu Z; Chen CS Mechanical Regulation of Cell Function with Geometrically Modulated Elastomeric Substrates. Nat Methods 2010, 7 (9), 733–736. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (30).Liu AP; Chaudhuri O; Parekh SH New Advances in Probing Cell-Extracellular Matrix Interactions. Integrative Biology (United Kingdom). 2017, 9, 383–405. [DOI] [PMC free article] [PubMed] [Google Scholar]
- (31).Yang MT; Fu J; Wang YK; Desai RA; Chen CS Assaying Stem Cell Mechanobiology on Microfabricated Elastomeric Substrates with Geometrically Modulated Rigidity. Nat Protoc 2011, 6 (2), 187–213. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.