Skip to main content
JAMA Network logoLink to JAMA Network
. 2023 Mar 28;6(3):e235102. doi: 10.1001/jamanetworkopen.2023.5102

Use of a Deep-Learning Algorithm to Guide Novices in Performing Focused Assessment With Sonography in Trauma

I-Min Chiu 1,2, Chun-Hung Richard Lin 1, Fei-Fei Flora Yau 2, Fu-Jen Cheng 2, Hsiu-Yung Pan 2, Xin-Hong Lin 2, Chi-Yung Cheng 1,2,
PMCID: PMC10051044  PMID: 36976564

Abstract

This quality improvement study compares the diagnostic quality and completion time between ultrasonography operators guided by artificial intelligence vs those without such assistance.

Introduction

Focused Assessment with Sonography in Trauma (FAST) could play a role in reduced time to operative care, shortened hospital length of stay, and lower medical costs.1 In a 2005 study, using prehospital FAST was associated with changes to the admitting hospital in 22% of patients.2,3 Ultrasonography is highly operator-dependent, and the FAST examination is considered to be among the hardest protocols for image interpretation.4 Thus, this study aimed to examine the association between artificial intelligence (AI) guidance and quality of FAST performed by novice ultrasonography operators.

Methods

This quality improvement study was conducted from March 20 to April 20, 2022. Thirty operators, including 10 registered nurses, 10 nurse practitioners (NPs), and 10 emergency medical technicians (EMTs) without prior experience in performing ultrasonography, were recruited and randomized to a study group: with AI guidance or without AI guidance. The Chang Gung Medical Foundation Institutional Review Board approved the study. Written informed consent was obtained from all participants before the abdominal ultrasonography. We followed the SQUIRE reporting guideline.

To enable AI guidance, we integrated the deep learning (DL)–based guidance algorithm that we developed5 into an OpenCV application that captures images from ultrasonography machines and provides real-time quality feedback (Video). This DL algorithm was found to classify qualified and nonqualified images with an accuracy of 0.941.5 Each operator was instructed to perform FAST examination over the Morrison pouch in 10 healthy patients (the model group) in the same order to obtain a 5-second clip of the standard view within 3 minutes.

Video. Demonstration of Real-Time Artificial Intelligence–Guided Ultrasonography With Quality and Result Feedback.

Download video file (14.7MB, mp4)

The image quality and confidence level of the interpretation are displayed in the upper left corner, and the interpretation result of the presence of ascites is displayed in the upper right corner. When the scanning position is correct, a prompt will appear to instruct the operator to “hold the probe.”

The primary outcome was diagnostic quality, which our panel of 3 expert echocardiographers (F.-J.C., H.-Y.P., X.-H.L.) assessed independently. Diagnostic quality was rated from 1 to 5, with higher scores representing better quality (eAppendix in Supplement 1). A rating of 4 or higher was considered to be acceptable quality for clinical use. The secondary outcome was time to complete examinations. We performed regression analysis to adjust for confounding factors (Table) and analyze the association of AI guidance with diagnostic quality.

Table. Regression Analysis of AI Guidance on Different Study Outcomes.

Outcome Variable OR (95% CI) P value
Acceptable quality score ≥4 Work tenure, y 1.04 (0.95 to 1.12) .31
Model group BMI 0.96 (0.85 to 1.08) .51
With AI guidance 3.82 (1.78 to 8.20) <.001
Diagnostic quality score Work tenure, y 0.00 (−0.03 to 0.03) .82
Model group BMI −0.05 (−0.09 to 0.00) .06
With AI guidance 0.40 (0.12 to 0.68) .005
Time to complete examination, s Work tenure, y −0.66 (−2.00 to 0.68) .33
Model group BMI 2.37 (0.28 to 4.45) .03
With AI guidance 14.36 (2.03 to 26.71) .02

Abbreviations: AI, artificial intelligence; BMI, body mass index (calculated as weight in kilograms divided by height in meters squared); OR, odds ratio.

Two-sided P < .05 indicated statistical significance. Data analysis was performed with SPSS, version 26 (IBM).

Results

A total of 300 ultrasonography scans were created by 30 operators. The model group consisted of 5 males and 5 females, with a median (IQR) age of 46 (35-50) years and body mass index (calculated as weight in kilograms divided by height in meters squared) ranging from 21.5 to 27.8. The intraclass correlation coefficient for diagnostic quality scores was 0.97 (95% CI, 0.96-0.98), indicating excellent reliability.

The median (IQR) quality score (5 [4-5] vs 4 [3-5]; P = .02) and the mean (SD) rate of acceptable quality score (126 [84%] vs 102 [68%]; P = .002) were higher in operators with AI guidance vs those without AI guidance. Additionally, AI guidance was associated with a higher quality score (odds ratio [OR], 0.40; 95% CI, 0.12-0.68; P = .005) and rate of acceptable quality (OR, 3.82; 95% CI, 1.78-8.20; P < .001) (Table).

Furthermore, AI guidance was associated with longer examination time (OR, 14.36; 95% CI, 2.03-26.71 seconds; P = .02) (Table), which was mostly observed in the first few rounds of operations (Figure). In a subgroup analysis of operators’ occupational position, AI guidance was associated with better diagnostic quality among NPs and EMTs (Figure).

Figure. Comparison of Diagnostic Quality and Operating Time Between Operators With Artificial Intelligence (AI) Guidance and Without AI Guidance .

Figure.

EMT indicates emergency medical technician; NP, nurse practitioner.

aStatistical difference in the acceptable quality rate.

Discussion

This study showed that the DL algorithm can guide novices to obtain satisfactory diagnostic images over the Morison pouch. The diagnostic quality score and the rate of acceptable clips were significantly higher with AI guidance. Although initially it may take longer to complete an examination with AI guidance, it is expected that the learning curve will be lower for novices practicing FAST. A study limitation is that it was conducted in a laboratory rather than a clinical trauma setting. To fully evaluate the potential benefits of using AI in the management of patients with traumatic injury, further research in clinical deployment is necessary.

Supplement 1.

eAppendix. Grading Scale for Quality of Ultrasound Scan

Supplement 2.

Data Sharing Statement

References

  • 1.Mazur SM, Pearce A, Alfred S, Goudie A, Sharley P. The F.A.S.T.E.R. trial. Focused assessment by sonography in trauma during emergency retrieval: a feasibility study. Injury. 2008;39(5):512-518. doi: 10.1016/j.injury.2007.11.010 [DOI] [PubMed] [Google Scholar]
  • 2.Walcher F, Weinlich M, Conrad G, et al. Prehospital ultrasound imaging improves management of abdominal trauma. Br J Surg. 2006;93(2):238-242. doi: 10.1002/bjs.5213 [DOI] [PubMed] [Google Scholar]
  • 3.Pinto A, Pinto F, Faggian A, et al. Sources of error in emergency ultrasonography. Crit Ultrasound J. 2013;5(Suppl 1)(suppl 1):S1. doi: 10.1186/2036-7902-5-S1-S1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Blehar DJ, Barton B, Gaspari RJ. Learning curves in emergency ultrasound education. Acad Emerg Med. 2015;22(5):574-582. doi: 10.1111/acem.12653 [DOI] [PubMed] [Google Scholar]
  • 5.Cheng CY, Chiu IM, Hsu MY, Pan HY, Tsai CM, Lin CR. Deep learning assisted detection of abdominal free fluid in Morison’s pouch during focused assessment with sonography in trauma. Front Med (Lausanne). 2021;8:707437. doi: 10.3389/fmed.2021.707437 [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplement 1.

eAppendix. Grading Scale for Quality of Ultrasound Scan

Supplement 2.

Data Sharing Statement


Articles from JAMA Network Open are provided here courtesy of American Medical Association

RESOURCES