Review of physical activity measurement using accelerometers in older adults: Considerations for research design and conduct

Susan L Murphy 1,*
PMCID: PMC10071821  NIHMSID: NIHMS1884313  PMID: 19111780

Abstract

Objective.

Accelerometers are being increasingly used in studies of physical activity (PA) among older adults, however the use of these monitors requires some specialized knowledge and up-to-date information on technological innovations. The purpose of this review article is to provide researchers with a guide to some commonly-used accelerometers in order to better design and conduct PA research with older adults.

Methods.

A literature search was conducted to obtain all available literature on commonly-used accelerometers in older adult samples with specific attention to articles discussing research design.

Results.

The use of accelerometers in older adults requires a basic understanding of the type being used, rationale for their placement, and attention to calibration when needed. The updated technology in some monitors should make study conduct less difficult, however comparison studies of the newer versus the older generation models will be needed.

Conclusions.

Careful considerations for design and conduct of accelerometer research as outlined in this review should help to enhance the quality and comparability of future research studies.

Keywords: Physical activity, Measurement, Review


Engagement in physical activity (PA) is a health behavior that can positively impact the severity and course of chronic diseases. The health benefits include decreased mortality rates; lower incidence of developing diseases; maintenance of conditions such as hypertension, diabetes, and obesity; reduction of fall risk; improvement in mood and well-being; and the lessening of functional decline (Pate et al., 1995; Taylor et al., 2004; Kahn et al., 2002; Karmisholt et al., 2005). Physical activity is also particularly beneficial to people with osteoarthritis, a leading cause of disability among older adults (Centers for Disease and Prevention, 2001). Studies have shown that PA of different intensities can prevent or forestall disability in people with osteoarthritis (Dunlop et al., 2005; Feinglass et al., 2005; Penninx et al., 2001). Even participation in low intensity activities has been found to be protective against the development of difficulty in activities of daily living such as stair climbing, walking, and bathing over a 2 year period.(Feinglass et al., 2005).

Physical activity measurement

Physical activity is often assessed using self-report measures. These measures are easy to administer and can provide information on the types of activities performed, but may not capture activity patterns throughout the day (Davis and Fox, 2007). Some measures also include calculations to estimate energy expenditure based on the duration and frequency of reported activity participation (Dipietro et al., 1993; Stewart et al., 2001). However, there are some disadvantages to using self-report measures such as recall bias, and in older adults in particular, self-report may also be influenced by fluctuations in health status and mood, depression, anxiety, or cognitive ability (Rikli, 2000). In addition, self-report PA measures designed for younger adults have been shown to be inaccurate when given to older adult samples, particularly underestimating the performance of light and moderate intensity activities (Washburn, 2000).

Objective PA measures have been increasingly used to overcome limitations of self-report measures. Accelerometry, in particular, provides information on the amount, frequency, and duration of PA (Plasqui and Westerterp, 2007). Data can be obtained about daytime and nighttime activity patterns and activity intensity (including estimates of energy expenditure) as they occur in people's daily lives. Although accelerometry provides only crude information on the types of activity in which people participate, Crouter et al. (2006) devised a statistical method using variability of estimates, specifically the coefficient of variation, to differentiate “free-living” activities (i.e. those that occur in a non-structured way during daily routines) from activities such as walking and running.

Objective PA measurement techniques can assess free-living activity which, similar to structured exercise, has been shown to have health benefits. It was recently shown that participation in nonexercise PA (such as housework and climbing stairs) improves mortality risk (Matthews et al., 2007). Other interventions that are designed to build PA (such as walking and stair climbing) into daily routines have shown effects of improved physical fitness in obese women (Andersen et al., 1999) and improved physical function and pain in recent breast cancer survivors (Basen-Engquist et al., 2006). Incorporating free-living activity into the daily routines of older adults is one potential way to promote long-term adoption of PA engagement.

Energy expenditure is often of interest to measure in studies when the outcome is activity intensity. Doubly-labeled water is considered the gold standard to measure energy expenditure over time. It is a method of indirect calorimetry in which carbon dioxide production is tracked from metabolism of specific isotopes in the labeled water. The technique is expensive and requires specific expertise, therefore it is not feasible in many clinical studies or in larger field and epidemiological studies.

This paper will focus on the use of accelerometers which are now often preferred in clinical studies due to their feasibility and general ease of use. Despite the frequent use of these monitors, there is no concise guide for researchers when using them in older adult populations.

Older adults and physical activity

There are several issues concerning physical activity measurement that are unique to the older adult population. First, older adults differ from younger adults and children in the type and intensity of activities in which they engage. Compared to the other age groups, older adults spend a higher percentage of their day performing low intensity activities and a lower percentage performing high intensity activities (Westerterp, 2008). These patterns may be due to age-related changes which include loss of flexibility, decreased bone and muscle mass, and decreased ability of the cardiac and respiratory systems to adapt to more intense physical activity (Skinner, 2006). Second, age-related declines in basal metabolic rate and decreased fat free mass may contribute to errors in energy expenditure calculations that were developed using younger adult samples. Third, chronic conditions increase in prevalence with aging and can affect physical activity levels. Fourth, problems with memory and recall among older adults may affect compliance of wearing monitors over a series of days.

This review paper seeks to provide some necessary information when designing and conducting a study using an accelerometer in older adult samples and will also focus on recently updated technology. A literature search was conducted to obtain all available literature from 1998–present on commonly-used accelerometers in older adult samples with specific attention to articles discussing research design. The literature search only spanned the last 10 years because this was thought to be best reflective of technology that still may be in use. A variety of search strategies were used to identify relevant articles. Using the electronic databases MEDLINE and CINAHL, search terms were: physical activity, physical activity measurement, energy expenditure, accelerometers, accelerometry, actiwatch, actigraph, review, validity, reliability, adults, older adults, and elderly. In addition, the author's own bibliographic records were searched as well as a search of the reference lists of research articles and review articles. After all literature was retrieved, it was organized for this review around main considerations of using an accelerometer, information about the different types and new technology, and other aspects of choosing a monitor for older adult samples.

Accelerometer types

The most commonly used accelerometers have piezo-electric sensors. Piezo-electric sensors measure acceleration due to movement and there are two main types, the cantilever beam and the integrated circuit (IC) chip. A thorough explanation of these sensors can be found in Chen and Bassett, 2005 and Mathie et al., 2004. Because the type of sensor in an accelerometer impacts the design and protocol of studies, some basic information will be presented here. The cantilever beam technology is named for the beam that is attached to a support at one side that contains a piezoelectric element and a seismic mass. When acceleration is detected by the seismic mass, it causes the piezoelectric element in the beam to bend and record a voltage signal (Chen and Bassett, 2005). The amplitude of the voltage signal is in proportion to the acceleration detected (Mathie et al., 2004).

The IC chip technology is in many of the newer generations of activity monitors. It also has a piezoelectric element and seismic mass that detects acceleration, but the sensor is fully enclosed in a package that is directly affixed on an electronic circuit board. This is advantageous in particular because it enhances durability and repeatability of the monitors. Among these newer generation accelerometers, some have a rechargeable battery as opposed to coin cell batteries which may reduce supply costs for researchers. Another important enhancement among some of the newer generation accelerometers (such as the Actiwatch Spectrum) is a skin conductance feature that can help researchers distinguish sedentary activity from not wearing the monitor. Given that older adults generally engage in many sedentary activities, this feature will increase the accuracy of overall physical activity estimates.

Table 1 shows some common accelerometer brands by the type of technology and identifies the newer generation brands where possible. One advantage of using accelerometers with the cantilever beam technology is that there is a body of literature on validity and reliability of these monitors (see Table 2). Most literature on daytime physical activity using accelerometry involves the use of the Actigraph (Actigraph LLC) brand monitors, where most literature on nighttime activity and sleep patterns involves the use of the Actiwatch (Mini Mitter Co) brand. The main disadvantage of using accelerometers with the cantilever beam technology is the need to be attentive to their calibration. Most companies test each monitor for its ability to sample data in a similar way before shipping. However, the cantilever beam accelerometers have the potential to break or become less reliable over time (Jack McKenzie, Director of Clinical Affairs, Mini Mitter Company, personal communication). Some manufacturers suggest preventive checks on monitors periodically which require them to be sent back to the company for recalibration. When using a cantilever beam accelerometer, it is recommended that researchers have a calibration protocol in place, especially when using the monitors over time in intervention studies and to check the monitors before and after their use in the field (Welk, 2005). In a large population-based study in which participants ranged from children to adults (Troiano et al., 2008), 5% of the accelerometers provided to participants for a week long wearing period were no longer within the calibration specifications set by the manufacturer when returned and the data were excluded. Although calibration may be more of an issue in studies involving children because their activity patterns involve sporadic bouts of vigorous activity (Welk et al., 2000), the reliability of accelerometers used in studies of older adults is still not clear. Researchers may use calibration tools developed by the manufacturers themselves or use a laboratory shaker to check that the monitors are functioning within an acceptable range of error, often represented by the coefficient of variability (Ward et al., 2005). Other suggestions to control for variability among monitors is to randomize them across participants in a study or consider adding the monitor worn as a variable in analysis to remove the error due to differences between monitors (Welk, 2005).

Table 1.

Types of piezoelectric sensors in accelerometers by brand

Company Cantilever beam IC chip
Actigraph LLC, Pensacola, FL Actigraph 7164 (formerly CSA, MTI) Actigraph GT1M
Actigraph 71256
Mini-Mitter Company, Sun River, OR Actiwatch-Score
Actiwatch-64 Actiwatch 2
Actiwatch-L Actiwatch Spectrum
Actical
IM Systems, Baltimore, MD Actitrac
Biotrainer
Stayhealthy Inc., Monrovia, CA R3D-Tritrac RT3- Triaxial Research Tracker

Table 2.

Overview of commonly-used accelerometers

Name Manufacturer Type* Size and weight Cost Placement Epoch length Memory capacity What it provides Validity/reliability
Actigraph Model 7164 [formerly CSA, MTI] Actigraph LLC Pensacola, FL Uniaxial 5.1×41×1.5 cm
45.5 g
N/A for purchase Usually hip, also ankle/wrist Records activity in 5 s to 1 min. epochs Records up to 22 d of data when using 1 min. epochs Activity counts
Energy expenditure
Welk et al., 2000
Welk et al., 2004
Freedson et al., 1998
Hendelman et al., 2000
Crouter et al., 2006
Rothney et al., 2008a,b
Moeller et al., 2008
McClain et al., 2007
Esliger and Tremblay, 2006
Actical Mini-Mitter Sunriver, OR Uniaxial; Omni-directional 2.8×2.7×1.0 cm
17.5 g
$950 w/software
$450 per unit
Wrist, hip, or ankle Records epochs from 15 s to 1 min. Stores up to 45 d of data using 1 min. epochs Activity counts
Step counts
Energy expenditure
Welk et al., 2004
Crouter et al., 2006
Rothney et al., 2008a,b
Esliger and Tremblay, 2006
Esliger et al., 2007
Heil, 2006
Klippel NJ, 2003
Actiwatch AW16 or AW64 Mini-Mitter Sunriver, OR Uniaxial; Omni-directional 2.8×2.7×1.0 cm
16 g
$1966 w/software
$985 per unit
Hip or wrist Records epochs 15 s to 15 min AW16 records up to 11 d of data using 1 min. epochs; AW64 up to 45 d Activity counts
Sleep quality
Chen et al., 2003
Gironda et al., 2007
Actitrac IM Systems Baltimore, MD Biaxial 5.6×3.8×13 cm
34 g
$799 per unit
$399 for software
$99 for cable
Wrist Records epochs 2 s to 2 min Records up to 44 d of data when using 1 min. epochs Activity counts Welk et al., 2003
Biotrainer IM Systems Baltimore, MD Biaxial 7.6×5×2.2 cm
51.1 g
$199 per unit
$199 for software
$99 for cable
Hip Records activity in 15 s to 5 min. epochs Records up to 22 d of data when using 1 min. epochs Activity counts
Converted into ‘g’ units or kilocalories expended
Welk et al., 2000
Welk et al., 2003
GT1M Actigraph Actigraph LLC Pensacola, FL Biaxial 33×3.7×1.8 cm
27 g
$335 per unit
$349 for software
Hip or waist Records activity in epochs of 1 s to several minutes Records up to 378 d of data when using 1 min. epochs Activity counts
Step counts
Energy expenditure
Sleep quality
Corder et al., 2007
Rothney et al., 2008a,b
Actiwatch Spectrum Mini-Mitter Sunriver, OR Uniaxial; Omni-directional 49×3.7×1.4 cm
29.8 g
$1599 per unit
$399 for reader/charger unit
waist Records activity in 15 s to 1 min. epochs Records up to 36 d of data when using 1 min. epochs Activity counts sleep quality
Actiwatch 2 Mini-Mitter Sunriver, OR Uniaxial; Omni-directional 4.4×23×1 cm
16.1 g (with band)
$999 per unit
$299 reader
waist Records activity in 15 s to 1 min. epochs Records up to 30 d of data when using 1 min. epochs Activity counts
Sleep quality
RT3-Triaxial Research Tracker [formerly R3D] Stayhealthy Inc. Monrovia, CA Triaxial 7.1×5.6×2.8 cm
65.2 g
$200 per unit
$300 for docking station
Hip or waist Records activity in 1 s to 1 min. epochs Records up to 7 d of data when using 1 min. epochs Activity counts for each plane: vertical, horizontal, mediolateral Energy expenditure Rothney et al., 2008a,b
Esliger and Tremblay, 2006
Powell and Rowlands, 2004

Note. s = seconds; min = minutes, d = days.

*

Uniaxial refers to accelerometers which measure acceleration in one plane, usually vertical to the ground. Omni-directional refers to a single beam accelerometer that detects acceleration primarily in one plane but also incidentally in two others. Biaxial and triaxial refer to accelerometers which measure acceleration in two or three planes respectively.

price quotes as of August, 2008.

Adult population articles concerning physical activity only.

Placement of monitors

In addition to monitor reliability, protocol decisions made by researchers may affect the validity of the output. The output of an accelerometer depends on the position at which it is placed, its orientation, posture, and activity being performed (Mathie et al., 2004. Because of this, different acceleration signals are recorded depending on placement.

Monitors record acceleration in different axes or planes of movement. These monitors are often described as uniaxial, biaxial, or triaxial for the axis or plane (e.g. vertical, anteroposterior, lateral) in which the monitor is most sensitive at detecting acceleration. Most commonly used cantilever beam monitors are usually referred to as “uniaxial” because they are most sensitive in the axis of bending (vertical). Some monitors have been described as “omni-directional” because the configuration of the cantilever also allows the piezoelectric element to bend in other directions; however, the contribution of these added directions are not distinguishable (Chen and Bassett, 2005). Some monitors may have more than one piezoelectric sensor to sample additional planes of movement. Table 2 has information about the specifications of some commonly-used monitors and provides some updated information from a previous review article (Trost et al., 2005).

In a clinical study, the type of monitor or monitors chosen depends on the motion of interest and the investigator's primary outcome variables. Whole body movement can be measured by a three dimensional monitor or by multiple monitors. Often one monitor is placed near the center of mass to approximate whole body movement and energy expenditure. However, the output of monitors depends on placement and is activity-specific. For example, upper extremity movement of stroke survivors has been assessed using a wrist-worn monitor (Green, 2007). Gait and balance have been assessed using hip or trunk worn accelerometers and a combination of monitors have been used to distinguish sit to stand movements in the clinic (Culhane et al., 2005). In addition, sleep and wake patterns are often measured using wrist-worn activity monitors (Morgenthaler et al., 2007); however, wrist worn accelerometers are not recommended to approximate energy expenditure (Trost et al., 2005).

When measuring energy expenditure, the hip or waist is the most common site to wear an accelerometer. The manufacturers have different instructions for how to don the monitors and may recommend wearing the monitor over one hip or anywhere on the waist. There is a lack of detailed information about positioning monitors in some common user manuals and positioning protocols may not be reported in research studies using the monitors. However, the positioning of monitors appears to be one potential source of error in studies. Welk (2002) found that a uniaxial monitor (the Actigraph) had significantly different results depending on which of three positions it was worn about the hip; however, no significant differences were seen on these three positions for the Biotrainer or Tritrac. In addition, which hip the monitor is worn on is also a consideration. In a recent study, the RT3 triaxial monitor worn on the left or right hips generated significantly different activity counts depending on its position during the performance of lab-based functional tasks for older adult participants (Sumukadas et al., 2008). Positioning of the monitor can also be an issue when data are collected over a series of days (Welk, 2005) because of less supervision and guidance on wearing it appropriately. Having a snug fit between the monitor and the person has been recommended to limit extraneous movement (Actigraph, 2008). It is not clear whether different options of wearing the device (for example having the monitor on a belt clip versus on a waist belt) contributes to significant differences in activity counts. In the future, more studies are needed to examine the variability of the actual placement of monitors in field-based studies among older adult participants and whether this affects physical activity estimates.

Number of days worn

Another consideration for using accelerometers is the length of time they are worn. Trost et al. 2005 outlines a commonly-used technique (variance partitioning) in which researchers determine the number of days needed to be measured to achieve a desired level of reliability based on the expected between and within subject variance. The number of days sampled depends on the outcome of interest (i.e. habitual physical activity, time spent in moderate intensity activity, inactivity) although typically the sampling period is between 3 and 7 days (Trost et al., 2005). If nighttime activity, such as sleep patterns, is of interest, recent practice parameters recommend at least 3 days of monitor wear (Morgenthaler et al., 2007). Gretebeck and Montoye (1992) suggested that both weekend and weekdays should be sampled, although it is not yet clear from studies if there is sufficient variability between these types of days for older adults.

Compliance and periods of missing data

Compliance by participants wearing accelerometers may also be inconsistently reported in the research literature. Several different approaches can be undertaken by researchers to promote compliance including a daily monitoring log filled out by participants, reminder phone calls, adequate education about the monitor and its proper wear, and identification of potential barriers to wearing with each participant (Trost et al., 2005). Concrete instructions about compliance may be particularly important to provide for older adults given issues with memory and recall. Based on personal experience using accelerometers with older adults, the daily logs are a fundamental tool for data analysis to determine times when the watch was not worn and have been consistently completed by participants. We also include compliance instructions in the daily logs. Because missing data periods can bias the results, imputation strategies are recommended (Catellier et al., 2005; Ward et al., 2005). There are no universal guidelines for data manipulation in the accelerometer literature, however, for study comparability, it is important that researchers clearly state their protocol for monitor wear and their decision rules for handling missing and spurious data (Masse et al., 2005). Consistency in using one monitor in studies of older adults could help build the evidence base along with standard protocols; however, the choice of monitor should depend on the outcome of interest and other factors discussed later in the paper.

Limitations of accelerometers

Accelerometers can be used to approximate energy expenditure, however, they do not capture the full energy cost of certain activities, such as walking while carrying a load or walking uphill, because acceleration patterns do not change under these conditions (Welk, 2002). Physical activity may also be underestimated depending upon the placement of the monitor. Other limitations include the financial cost of monitors, staff time to process and analyze data, and problems with monitor placement when data are collected over a number of days (Dale, Welk, and Matthews, 2002). In addition, although raw activity counts are frequently reported in studies, they are not easily interpretable.

Other methods of assessment

There are other methods of assessment that may be of interest to researchers to assess physical activity. Pedometers are inexpensive compared to methods such as doubly-labeled water or accelerometry. They are easy to use and can provide participants with feedback about their performance which may be an appealing feature for use in physical activity intervention studies. The main physical activity outcome using pedometers is step counts. The disadvantages of pedometers include inaccuracy in measurement of daily energy expenditure (Bassett et al., 2000) and lack of ability to measure physical activity patterns. For frail older adults, pedometers may not be an optimal method for assessment as accuracy is reduced at slow speeds (Cyarto et al., 2004; Le Masurier and Tudor-Locke, 2003). Pedometer accuracy is also reduced for people who have variable gait patterns (Cyarto et al., 2004) and for obese individuals (McClung et al., 2000). Some pedometers have piezoelectric components and have improved accuracy at slow speeds over traditional pedometers (Foster et al., 2005). For example, the Stepwatch-3 activity monitor is an ankle-worn pedometer with a piezoelectric component that also can measure physical activity patterns and is more accurate than other pedometers at slow speeds (Karabulut et al., 2005; Foster et al., 2005). However, it is also more expensive and requires a docking station and software.

Heart rate monitoring is another method of PA assessment, particularly for approximating energy expenditure. These monitors are inexpensive and can also provide information about activity duration and intensity; however, energy expenditure estimates can be confounded by other factors that increase heart rate such as caffeine or stress (Melanson and Freedson, 1996). The SenseWear WMS armband is a monitor that combines accelerometry with other physiologic measures (e.g. heart rate, galvanic skin response); however, limited information is available on the field-use of this device. Some preliminary support for validity and reliability of energy expenditure estimates has been established from lab-based studies in adults (Fruin and Rankin, 2004; Jakicic et al., 2004).

Choosing an accelerometer

Table 3 lists some general considerations for choosing an accelerometer for use in studies with older adults. Mathie et al. (2004) state that there are three types of monitoring that researchers may be interested in which affects the choice of monitor: clinical assessment (such as a one-time assessment of a participant in their home environment), event monitoring (such as fall events), and longitudinal monitoring of general or specific movements. In addition, monitors like the Actiwatch-Score have an added feature to allow participants to enter in responses on a scale that can range from 0–10 which has been used to sample within-day symptoms in rheumatic populations (Kop et al., 2005; Murphy et al., 2008a) and to rate the frequency of use of health behaviors (Murphy et al., 2008b). It is important to be aware that although different monitors may measure similar dimensions of PA, the choice of monitor should be guided by what most accurately measures the primary outcome of interest with regard to feasibility and reduction of participant burden. Feasibility may include the size of the study, the memory capacity of the monitor, and practical considerations such as equipment, supply costs, and technical support available for data processing. Participant burden is also important to consider when determining whether to use one or more monitors, placement, and length of wear.

Table 3.

Considerations for choosing a monitor

Type of monitoring
 Lifestyle PA
 Sleep
 Exercise
 Step counts
 Energy expenditure
Optimal for assessing primary outcome variable
Ease of wear for subject
 Monitor size
 Monitor weight
 Comfort of wear
 Location of monitor
 Clip versus belt
 Water-proof
Length of monitor wear needed
Size and scope of study
Cost of monitor
 Accessories
 Software
Expertise among research team, university, technical support
Amount of data manipulation needed

Many researchers are interested in approximating PA energy expenditure from accelerometers. This approximation is often done by using regression formulas provided by the accelerometer manufacturers. There is a large body of literature that examines how accelerometers estimate energy expenditure and a thorough review can be found in Chen and Bassett (2005). Recently a two level regression model was developed for both the Actical and Actigraph brand monitors across the same lab-based functional activities and participants in order to enhance comparability across these commonly-used monitors (Crouter and Bassett Jr., 2008, Crouter et al., 2006). This two-level method accounts for different types of activities that may improve the estimation of energy expenditure compared to a single regression model. However, more studies are needed to determine how well these equations estimate free-living PA and how they apply to older adult populations. In addition, the relationship between energy expenditure and PA may not always be linear (Chen et al., 2004; Ward et al., 2005) and nonlinear modeling has been shown to improve energy expenditure estimates in a study using a triaxial monitor (Chen and Sun, 1997). Future studies will be needed to develop population specific formulas to accurately estimate energy expenditure.

Future directions

The newer generation accelerometers offer some practical advantages to researchers and are tested by manufacturers to be equivalent to the older generation models. However, future studies will need to examine the generational comparability under different conditions. It is likely that the older monitors will still be actively used if they are already owned by researchers or generally available. In future publications, it will be important to know some of the measurement differences in these different generations of monitors in order to generalize across studies.

A few comparative studies of different generations of monitors have been published. Rothney and colleagues (2008a,b) found measurement differences among three generations of Actigraph brand accelerometers (the 7164, 71256, and the Actigraph GT1M). Specifically, compared to the older models, the GT1M had improved inter-monitor variability but decreased ability to monitor lower intensity activities. In a study of adolescents, Corder et al. (2007) found that the Actigraph GT1M model data was significantly different from the 7164 data when classifying time spent in light intensity versus sedentary activities.

Summary

The use of accelerometers in physical activity and older adult research has grown substantially in recent years. This article sought to provide a guide to the body of literature outlining use of these devices and update information on the recent technological advances that affect PA measurement. Careful considerations for design and conduct of accelerometer research will enhance the quality and comparability of future research studies.

Acknowledgments

Dr. Murphy is a currently the recipient of Academic Award K01HD045293 from the National Center for Medical Rehabilitation Research. I thank James Strasburg, Janice Chen, and Jessica Koliba for their assistance with gathering information on different monitors and Angela Lyden for reading earlier drafts of this article.

Footnotes

Conflict of interest

The author reports no financial conflicts with any of the companies listed in this manuscript.

References

  1. Actigraph, L.E.M., 2008. ActiLife Users Manual. Pensacola, FL. [Google Scholar]
  2. Andersen RE, Wadden TA, Bartlett SJ, Zemel B, Verde TJ, Franckowiak SC, 1999. Effects of lifestyle activity vs structured aerobic exercise in obese women: a randomized trial. JAMA 281, 335–340. [DOI] [PubMed] [Google Scholar]
  3. Basen-Engquist K, Taylor CLC, Rosenblum C, et al. , 2006. Randomized pilot test of a lifestyle physical activity intervention for breast cancer survivors. Patient Educ. Couns 64, 225–234. [DOI] [PubMed] [Google Scholar]
  4. Bassett DR, Ainsworth BE, Swartz AM, Strath SJ, O'Brien WL, King GA, 2000. Validity of four motion sensors in measuring moderate intensity physical activity. Med. Sci. Sports Exerc 32, S471–S480. [DOI] [PubMed] [Google Scholar]
  5. Catellier DJ, Hannan PJ, Murray DM, et al. , 2005. Imputation of missing data when measuring physical activity by accelerometry. Med. Sci. Sports Exerc 37, S555–S562. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Centers for Disease and Prevention, 2001. Prevalence of disabilities and associated health conditions among adults — United States, 1999. MMWR - Morb. Mort. Wkly. Rep 50, 120–125. [PubMed] [Google Scholar]
  7. Chen KY, Sun M, 1997. Improving energy expenditure estimation by using a triaxial accelerometer. J. Appl. Physiol 83, 2112–2122. [DOI] [PubMed] [Google Scholar]
  8. Chen KY, Acra SA, Majchrzak K, et al. , 2003. Predicting energy expenditure of physical activity using hip- and wrist-worn accelerometers. Diabetes Technol. Ther 5, 1023–1033. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Chen KY, Acra SA, Donahue CL, Sun M, Buchowski MS, 2004. Efficiency of walking and stepping: relationship to body fatness. Obes. Res 12, 982–989. [DOI] [PubMed] [Google Scholar]
  10. Chen KY, Bassett DR Jr., 2005. The technology of accelerometry-based activity monitors: current and future. Med. Sci. Sports Exerc 37, S490–S500. [DOI] [PubMed] [Google Scholar]
  11. Corder K, Brage S, Ramachandran A, Snehalatha C, Wareham N, Ekelund U, 2007. Comparison of two Actigraph models for assessing free-living activity in Indian adolescents. J. Sports Sci 25, 1607–1611. [DOI] [PubMed] [Google Scholar]
  12. Crouter SE, Bassett DR Jr., 2006. Estimating energy expenditure using accelerometers. Eur. J. of Appl. Physiol 98, 601–612. [DOI] [PubMed] [Google Scholar]
  13. Crouter SE, Clowers KG, Bassett DR Jr., 2006. A novel method for using accelerometer data to predict energy expenditure. J. Appl. Physiol 100, 1324–1331. [DOI] [PubMed] [Google Scholar]
  14. Crouter SE, Bassett DR Jr., 2008. A new 2-regression model for the Actical accelerometer. Br. J. Sports Med 42, 217–224. [DOI] [PubMed] [Google Scholar]
  15. Culhane KM, O'Connor M, Lyons D, Lyons GM, 2005. Accelerometers in rehabilitation medicine for older adults. Age Ageing 34, 556–560. [DOI] [PubMed] [Google Scholar]
  16. Cyarto EV, Myers AM, Tudor-Locke C, 2004. Pedometer accuracy in nursing home and community-dwelling older adults. Med. Sci. Sports Exerc 36, 205–209. [DOI] [PubMed] [Google Scholar]
  17. Dale D, Welk GJ, Matthews CE, 2002. Methods for assessing physical activity and challenges for research. In: Welk GJ (Ed.), Physical activity measurement for health related research. Human Kinetics, Champaign, pp. 19–34. [Google Scholar]
  18. Davis MG, Fox KR, 2007. Physical activity patterns assessed by accelerometry in older people. Eur. J. Appl. Physiol 100, 581–589. [DOI] [PubMed] [Google Scholar]
  19. Dipietro L, Caspersen CJ, Ostfeld AM, Nadel ER, 1993. A survey for assessing physical activity among older adults. Med. Sci. Sports Exerc 25, 628–642. [PubMed] [Google Scholar]
  20. Dunlop DD, Semanik P, Song J, Manheim LM, Shih V, Chang RW, 2005. Risk factors for functional decline in older adults with arthritis. Arthritis Rheum. 52, 1274–1282. [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Esliger DW, Tremblay MS, 2006. Technical reliability assessment of three accelerometer models in a mechanical setup. Med. Sci. Sports Exerc 38, 2173–2181. [DOI] [PubMed] [Google Scholar]
  22. Esliger DW, Probert A, Gorber SC, Bryan S, Laviolette M, Tremblay MS, 2007. Validity of the Actical accelerometer step-count function. Med. Sci. Sports Exerc 39, 1200–1204. [DOI] [PubMed] [Google Scholar]
  23. Feinglass J, Thompson JA, He XZ, Witt W, Chang RW, Baker DW, 2005. Effect of physical activity on functional status among older middle-age adults with arthritis. Arthritis Rheum. 53, 879–885. [DOI] [PubMed] [Google Scholar]
  24. Foster RC, Lanningham-Foster LM, Manohar C, 2005. Precision and accuracy of an ankle-worn accelerometer-based pedometer in step counting and energy expenditure. Prev. Med 41, 778–783. [DOI] [PubMed] [Google Scholar]
  25. Freedson PS, Melanson E, Sirard J, 1998. Calibration of the computer science and applications, inc. accelerometer. Med. Sci. Sports Exerc 30, 777–781. [DOI] [PubMed] [Google Scholar]
  26. Fruin ML, Rankin JW, 2004. Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med. Sci. Sports Exerc 36, 1063–1069. [DOI] [PubMed] [Google Scholar]
  27. Gironda RJ, Lloyd J, Clark ME, Walker RL, 2007. Preliminary evaluation of reliability and criterion validity of Actiwatch-Score. J. Rehabil. Res. Dev 44, 23–30. [DOI] [PubMed] [Google Scholar]
  28. Green LB, 2007. Assessment of habitual physical activity and paretic arm mobility among stroke survivors by accelerometry. Topics in Stroke Rehabilitation 14, 9–21. [DOI] [PubMed] [Google Scholar]
  29. Gretebeck RJ, Montoye HJ, 1992. Variability of some objective measures of physical activity. Med. Sci. Sports Exerc 24, 1167–1172. [PubMed] [Google Scholar]
  30. Heil DP, 2006. Predicting activity energy expenditure using the Actical activity monitor. Res. Q. Exerc. Sport 77, 64–80. [DOI] [PubMed] [Google Scholar]
  31. Hendelman D, Miller K, Baggett C, Debold E, Freedson P, 2000. Validity of accelerometry for the assessment of moderate intensity physical activity in the field. Med. Sci. Sports Exerc 32, S442–S449. [DOI] [PubMed] [Google Scholar]
  32. Jakicic JM, Marcus M, Gallagher KI, 2004. Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise. Med. Sci. Sports Exerc 36, 897–904. [DOI] [PubMed] [Google Scholar]
  33. Kahn EB, Ramsey LT, Brownson RC, et al. , 2002. The effectiveness of interventions to increase physical activity. A systematic review. Am. J. Prev. Med 22, 73–107. [DOI] [PubMed] [Google Scholar]
  34. Karabulut M, Crouter SE, Bassett DR Jr., 2005. Comparison of two waist-mounted and two ankle-mounted electronic pedometers. Eur. J. of Appl. Physiol 95, 335–343. [DOI] [PubMed] [Google Scholar]
  35. Karmisholt K, Gyntelberg F, Gotzche PC, 2005. Physical activity for primary prevention of disease. Systematic reviews of randomised clinical trials. Dan. Med. Bull 52, 86–89. [PubMed] [Google Scholar]
  36. Klippel NJ, H.D., 2003. Validation of energy expenditure prediction algorithms in adults using the Actical electronic activity monitor. Med. Sci. Sports Exerc 35, S284. [Google Scholar]
  37. Kop WJ, Lyden A, Berlin AA, et al. , 2005. Ambulatory monitoring of physical activity and symptoms in fibromyalgia and chronic fatigue syndrome. Arthritis Rheum. 52, 296–303. [DOI] [PubMed] [Google Scholar]
  38. Le Masurier GC, Tudor-Locke C, 2003. Comparison of pedometer and accelerometer accuracy under controlled conditions. Med. Sci. Sports Exerc 35, 867–871. [DOI] [PubMed] [Google Scholar]
  39. Masse LC, Fuemmeler BF, Anderson CB, et al. , 2005. Accelerometer data reduction: a comparison of four reduction algorithms on select outcome variables. Med. Sci. Sports Exerc 37, S544–S554. [DOI] [PubMed] [Google Scholar]
  40. Mathie MJ, Coster ACF, Lovell NH, Celler BG, 2004. Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement. Physiol. Meas 25, R1–R20. [DOI] [PubMed] [Google Scholar]
  41. Matthews CE, Jurj AL, Shu X-O, et al. , 2007. Influence of exercise, walking, cycling, and overall nonexercise physical activity on mortality in Chinese women. Am. J. Epidemiol 165, 1343–1350. [DOI] [PubMed] [Google Scholar]
  42. McClain JJ, Sisson SB, Tudor-Locke C, 2007. Actigraph accelerometer interinstrument reliability during free-living in adults. Med. Sci. Sports Exerc 39, 1509–1514. [DOI] [PubMed] [Google Scholar]
  43. McClung CD, Zahiri CA, Higa JK, Amstutz HC, Schmalzried TP, 2000. Relationship between body mass index and activity in hip or knee arthroplasty patients. J. Orthop. Res 18, 35–39. [DOI] [PubMed] [Google Scholar]
  44. Melanson EL Jr., Freedson PS, 1996. Physical activity assessment: a review of methods. Crit. Rev. Food Sci. Nutr 36, 385–396. [DOI] [PubMed] [Google Scholar]
  45. Moeller N, Korsholm L, Kristensen P, Andersen L, Wedderkopp N, Froberg K, 2008. Unit-specific calibration of Actigraph accelerometers in a mechanical setup - Is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the field. BMC Med. Res. Methodol 8, 19. [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Morgenthaler T, Alessi C, Friedman L, et al. , 2007. Practice parameters for the use of actigraphy in the assessment of sleep and sleep disorders. Sleep 30, 519–529. [DOI] [PubMed] [Google Scholar]
  47. Murphy SL, Smith DM, Clauw DJ, Alexander NB, 2008a. The impact of momentary pain and fatigue on physical activity in women with osteoarthritis. Arthritis Rheum. 59, 849–856. [DOI] [PMC free article] [PubMed] [Google Scholar]
  48. Murphy SL, Smith DM, Alexander NB, 2008b. Measuring activity pacing in women with osteoarthritis: A pilot study. Am. J. Occup. Ther 62, 329–334. [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Pate RR, Pratt M, Blair SN, et al. , 1995. Physical activity and public health. A recommendation from the Centers for Disease Control and Prevention and the American College of Sports Medicine. JAMA 273, 402–407. [DOI] [PubMed] [Google Scholar]
  50. Penninx BWJ, Messier SP, Rejeski WJ, et al. , 2001. Physical exercise and the prevention of disability in activities of daily living in older persons with osteoarthritis. Arch. Intern. Med 161, 2309–2316. [DOI] [PubMed] [Google Scholar]
  51. Plasqui G, Westerterp KR, 2007. Physical activity assessment with accelerometers: an evaluation against doubly labeled water. Obesity 15, 2371–2379. [DOI] [PubMed] [Google Scholar]
  52. Powell SM, Rowlands AV, 2004. Intermonitor variability of the RT3 accelerometer during typical physical activities. Med. Sci. Sports Exerc 36, 324–330. [DOI] [PubMed] [Google Scholar]
  53. Rikli RE, 2000. Reliability, validity, and methodological issues in assessing physical activity in older adults. Res. Q. Exerc. Sport 71, S89–S96. [PubMed] [Google Scholar]
  54. Rothney MP, Schaefer EV, Neumann MM, Choi L, Chen KY, 2008a. Validity of physical activity intensity predictions by ActiGraph, Actical, and RT3 accelerometers. Obesity 16, 1946–1952. [DOI] [PMC free article] [PubMed] [Google Scholar]
  55. Rothney MP, Apker GA, Song Y, Chen KY, 2008b. Comparing the performance of three generations of Actigraph accelerometers. J. Appl. Physiol 105, 1091–1097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  56. Skinner JS, 2006. Aging for exercise testing and exercise prescription. In: Skinner JS (Ed.), Exercise testing and exercise prescription for special cases: Theoretical basis and clinical application. Lippincott, Williams & Wilkins, Philadelphia, pp. 85–99. [Google Scholar]
  57. Stewart AL, Mills KM, King AC, Haskell WL, Gillis D, Ritter PL, 2001. CHAMPS physical activity questionnaire for older adults: outcomes for interventions. Med. Sci. Sports Exerc 33, 1126–1141. [DOI] [PubMed] [Google Scholar]
  58. Sumukadas D, Laidlaw S, Witham MD, 2008. Using the RT3 accelerometer to measure everyday activity in functionally impaired older people. Aging Clin. Exp. Res 20, 15–18. [DOI] [PubMed] [Google Scholar]
  59. Taylor AH, Cable NT, Faulkner G, et al. , 2004. Physical activity and older adults: a review of health benefits and the effectiveness of interventions. J. Sports Sci 22, 703–725. [DOI] [PubMed] [Google Scholar]
  60. Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M, 2008. Physical activity in the United States measured by accelerometer. Med. Sci. Sports Exerc 40, 181–188. [DOI] [PubMed] [Google Scholar]
  61. Trost SG, McIver KL, Pate RR, 2005. Conducting accelerometer-based activity assessments in field-based research. Med. Sci. Sports Exerc 37, S531–S543. [DOI] [PubMed] [Google Scholar]
  62. Ward DS, Evenson KR, Vaughn A, Rodgers AB, Troiano RP, 2005. Accelerometer use in physical activity: best practices and research recommendations. Med. Sci. Sports Exerc 37, S582–S588. [DOI] [PubMed] [Google Scholar]
  63. Washburn RA, 2000. Assessment of physical activity in older adults. Res. Q. Exerc. Sport 71, S79–S88. [PubMed] [Google Scholar]
  64. Welk GJ, Corbin CB, Dale D, 2000. Measurement issues in the assessment of physical activity in children. Research Q. Exerc. Sport 71, 59–73. [DOI] [PubMed] [Google Scholar]
  65. Welk GJ, 2002. Use of accelerometry-based activity monitors to assess physical activity. In: Welk GJ (Ed.), Physical activity measurement for health related research. Human Kinetics, Champaign, pp. 125–141. [Google Scholar]
  66. Welk GJ, 2005. Principles of design and analyses for the calibration of accelerometry-based activity monitors. Med. Sci. Sports Exer 37, S501–S511. [DOI] [PubMed] [Google Scholar]
  67. Welk GJ, Almeida J, Morss G, 2003. Laboratory calibration and validation of the Biotrainer and Actitrac activity monitors. Med. Sci. Sports Exerc 35, 1057–1064. [DOI] [PubMed] [Google Scholar]
  68. Welk GJ, Blair SN, Wood K, Jones S, Thompson RW, 2000. A comparative evaluation of three accelerometry-based physical activity monitors. Med. Sci. Sports Exerc 32, S489–S497. [DOI] [PubMed] [Google Scholar]
  69. Welk GJ, Schaben JA, Morrow JR Jr., 2004. Reliability of accelerometry-based activity monitors: a generalizability study. Med. Sci. Sports Exerc 36, 1637–1645. [PubMed] [Google Scholar]
  70. Westerterp KR, 2008. Physical activity as determinant of daily energy expenditure. Physiol. Behav 93, 1039–1043. [DOI] [PubMed] [Google Scholar]

RESOURCES