Abstract
The reliability and validity of two tests (cold water and reactive hyperaemia) designed to confirm a patient's history of vibration induced white finger were studied. The cold water test is a measure of digital rewarming after hand immersion in cold water. Reactive hyperaemia consists of measuring digital rewarming after cold water immersion plus temporary ischaemia imposed on the hand. For ten weeks, ten healthy male volunteers were submitted once a week to both tests to study their reliability. The results showed a strong inter and intraindividual scattering. The mean value for the whole group, however, did not differ significantly from one week to the next. Fifty two subjects exposed to hand/arm vibration were submitted to both tests to estimate their validity. They were classified, according to their medical history, into three groups: A = no symptoms, B = tingling or numbess, or both, C = Raynaud's phenomenon. Both tests agreed with the clinical staging. For reactive hyperaemia, however, the differences between the groups were statistically significant only when the test was performed at 10 degrees C. These tests are more useful to study a group than an individual case. Time has no significant effect on the mean result of a group.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Brubaker R. L., Mackenzie C. J., Eng P. R., Bates D. V. Vibration white finger disease among tree fellers in British columbia. J Occup Med. 1983 May;25(5):403–408. [PubMed] [Google Scholar]
- Hellstrom B., Myhre K. A comparison of some methods of diagnosing Raynaud phenomena of occupational origin. Br J Ind Med. 1971 Jul;28(3):272–279. doi: 10.1136/oem.28.3.272. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Juul C., Nielsen S. L. Locally induced digital vasospasm detected by delayed rewarming in Raynaud's phenomenon of occupational origin. Br J Ind Med. 1981 Feb;38(1):87–90. doi: 10.1136/oem.38.1.87. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Krähenbühl B. Une méthode utile pour le diagnostic du phénomène de Raynaud: la suppression par le froid de l'hyperémie réactionnelle post-ischémique digitale. Schweiz Med Wochenschr. 1977 Dec 10;107(49):1831–1833. [PubMed] [Google Scholar]
- Miyashita K., Shiomi S., Itoh N., Kasamatsu T., Iwata H. Epidemiological study of vibration syndrome in response to total hand-tool operating time. Br J Ind Med. 1983 Feb;40(1):92–98. doi: 10.1136/oem.40.1.92. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Okada A., Yamashita T., Ideda T. Screening test for Raynaud's phenomenon of occupational origin. Am Ind Hyg Assoc J. 1972 Jul;33(7):476–482. doi: 10.1080/0002889728506689. [DOI] [PubMed] [Google Scholar]
- Okada A., Yamashita T., Nagano C., Ikeda T., Yachi A., Shibata S. Studies on the diagnosis and pathogenesis of Raynaud's phenomenon of occupational origin. Br J Ind Med. 1971 Oct;28(4):353–357. doi: 10.1136/oem.28.4.353. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Olsen N., Nielsen S. L., Voss P. Cold response of digital arteries in chain saw operators. Br J Ind Med. 1982 Feb;39(1):82–88. doi: 10.1136/oem.39.1.82. [DOI] [PMC free article] [PubMed] [Google Scholar]