Abstract

A portable body-monitoring system developed by the board uses two detectors, one for whole-body measurements and one for thyroid measurements. It can detect most commonly used gamma-ray emitting nuclides down to levels below those of interest for radiological protection purposes. The system has been used at 11 establishments including hospitals, universities, and research laboratories. Measurements have been made on 109 workers exposed to unsealed gamma-ray emitting material. Some activity other than that due to naturally occurring 40potassium was detected in a substantial proportion (30%) of those measured. The contaminating nuclides most often detected were 125iodine and 99mtechnetium. Some cases of contamination with 131iodine, 137caesium, 67gallium, and 85strontium were also detected. In most cases the level of activity detected was very low, but in three it was above the derived investigation level for routine monitoring of the nuclide concerned. The need for monitoring and possible monitoring programmes in which such a system would be useful are discussed.

Full text

PDF
189

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Massé F. X., Bolton M. M., Jr Experience with a low-cost chair-type detector system for the determination of radioactive body burdens of M.I.T. radiation workers. Health Phys. 1970 Jul;19(1):27–35. doi: 10.1097/00004032-197007000-00005. [DOI] [PubMed] [Google Scholar]
  2. Palmer H. E., Branson B. M., Cohn S. H., Dean P. N., Eckart J. A., Lloyd R. D., Miller C. E. Standard field methods for determining 137Cs and 131I in vivo. Health Phys. 1976 Jan;30(1):113–118. doi: 10.1097/00004032-197601000-00012. [DOI] [PubMed] [Google Scholar]
  3. Schulz A. G., Rollo F. D. A method for measuring radioiodine uptake which corrects for thyroid depth. J Nucl Med. 1970 Aug;11(8):508–513. [PubMed] [Google Scholar]
  4. Shleien B., LeCroy E., Jr Results of thyroid and whole-body counting of some medical and paramedical personnel. J Nucl Med. 1971 Jul;12(7):523–525. [PubMed] [Google Scholar]

Articles from British Journal of Industrial Medicine are provided here courtesy of BMJ Publishing Group