Abstract
Aims
This study aims to compare biomarkers of potential harm between people switching from smoking combustible cigarettes (CC) completely to electronic cigarettes (EC), continuing to smoke CC, using both EC and CC (dual users) and using neither (abstainers), based on behaviour during EC intervention studies.
Design
Secondary analysis following systematic review, incorporating inverse variance random‐effects meta‐analysis and effect direction plots.
Setting
This study was conducted in Greece, Italy, Poland, the United Kingdom and the United States.
Participants
A total of 1299 adults smoking CC (nine studies) and provided EC.
Measurements
Measurements were conducted using carbon monoxide (CO) and 26 other biomarkers.
Findings
In pooled analyses, exhaled CO (eCO) was lower in EC versus EC + CC [mean difference (MD) = −4.40 parts per million (p.p.m.), 95% confidence interval (CI) = −12.04 to 3.24, two studies] and CC (MD = −9.57 p.p.m., 95% CI = −17.30 to −1.83, three studies). eCO was lower in dual users versus CC only (MD = −1.91 p.p.m., 95% CI = −3.38 to −0.45, two studies). Magnitude rather than direction of effect drove substantial statistical heterogeneity. Effect direction plots were used for other biomarkers. Comparing EC with CC, 12 of 13 biomarkers were significantly lower in EC users, with no difference for the 13th. Comparing EC with dual users, 12 of the 25 biomarkers were lower for EC, and five were lower for dual use. For the remaining eight measures, single studies did not detect statistically significant differences, or the multiple studies contributing to the outcome had inconsistent results. Only one study provided data comparing dual use with CC; of the 13 biomarkers measured, 12 were significantly lower in the dual use group, with no statistically significant difference detected for the 13th. Only one study provided data on abstainers.
Conclusions
Switching from smoking to vaping or dual use appears to reduce levels of biomarkers of potential harm significantly.
Keywords: Electronic cigarettes, biomarkers, carbon monoxide, tobacco, smoking cessation, systematic review
INTRODUCTION
Scientific consensus overwhelmingly holds that nicotine electronic cigarettes (ECs), although not risk‐free, are considerably lower risk than combustible tobacco, as they provide a means to inhale nicotine without combustion [1, 2]. However, uncertainty persists around the health impacts in people who smoke who switch to EC completely, or who both smoke and use ECs (dual users) [1]. Without long‐term safety data, biomarkers of potential harm are often used to inform best estimates about relative benefits and harms of ECs compared to combustible tobacco. Biomarkers of potential harm include exhaled carbon monoxide (eCO), known carcinogens and other toxicants identified by regulatory bodies [3].
Our Cochrane living systematic review of ECs for smoking cessation evaluates changes in biomarkers between groups randomized using an intention‐to‐treat principle [4]. This means that we compare differences in biomarkers of harm between those randomized to an EC condition and those randomized to a control condition. This follows standard Cochrane methods and is a pragmatic approach which best reflects the effects of such interventions delivered in real life. However, as with all smoking cessation trials, most people in these studies do not quit smoking successfully. In the EC condition, some participants will not use EC, and many will continue to use combustible cigarettes. In the control condition, some participants will use EC of their own accord. Most will also continue to use combustible cigarettes [4].
Although it is important to analyse the impact of the randomized interventions by group, there is also value in knowing how biomarkers of harm change based on participants’ actual behaviour. Such analyses can inform debates concerning potential harms and benefits of dual use. They can also illustrate the changes that someone who smokes might expect to see if they switched completely to ECs or commenced dual use. Therefore, in this secondary analysis of trials included in our Cochrane review, we set out to compare biomarkers of potential harm between four groups, based on actual product use rather than group assignment: those switching completely to ECs, those not using EC and continuing to smoke combustible cigarettes (CC), those using both EC and CC (dual use) and those using neither (abstainers).
METHODS
This is a secondary analysis using data identified to January 2022 in a Cochrane living systematic review [4]. The following databases were searched: Cochrane Tobacco Addiction Group Specialized Register, Cochrane Central Register of Controlled Trials, MEDLINE, Embase, PsycINFO, ClinicalTrials.gov and WHO International Clinical Trials Registry Platform. Full search methods can be found in the parent review [4]. A protocol was registered in advance (https://osf.io/g6bw3/).
Inclusion criteria
Inclusion criteria were as per the parent review; namely, studies of EC interventions provided to adults who smoke for the purpose of smoking cessation, including randomized controlled trials, cross‐over trials and non‐randomized intervention studies. To be included in this analysis, studies had to report at least one of the following at 1 week or longer from study start, and data had to be available based on observed or self‐reported use of EC and CC:
Carbon monoxide (CO); we anticipated that this would be the most common measure among studies as it can be collected relatively easily
Any other known biomarkers of potential harm (see Table 1)
TABLE 1.
Biomarker class | Biomarker | Group comparisons | ||
---|---|---|---|---|
EC versus CC | EC versus EC + CC | Dual use (EC + CC) versus CC | ||
Mercapturic acids | 3‐HPMA (3‐hydroxypropylmercapturic acid) |
↓↓ Cravo ↓↓ Morris |
↔ McRobbie ↓ Goniewicz ↓↓ Morris ↔ Pulvers |
↓↓ Morris |
SPMA (S‐phenylmercapturic acid) |
↓↓ Cravo ↓↓ Morris |
↓ Goniewicz ↓↓ Morris |
↓↓ Morris | |
HEMA (2‐hydroxyethylmercapturic acid) | ↓↓ Morris |
↑ Goniewicz ↔ Morris ↔ Pulvers |
↓↓ Morris | |
MHBMA (2‐hydroxy‐3‐buten‐1‐ylmercapturic acid) | ↓↓ Morris |
↓ Goniewicz ↓ Morris |
↓↓ Morris | |
HPMMA (3‐hydroxy‐1‐methyl propylmercapturic acid) |
↓ Goniewicz ↔ Pulvers |
|||
AAMA (N‐acetyl‐S‐(carbamoylethyl)‐l‐cysteine (synonym: 2‐carbamoylethylmercapturic acid)) |
↓ Goniewicz ↓↓ Pulvers |
|||
CNEMA (2‐cyanoethylmercapturic acid) | ↓↓ Morris |
↓ Goniewicz ↓↓ Pulvers ↓↓ Morris |
↓↓ Morris | |
2‐HPMA (2‐hydroxypropylmercapturic acid) |
↓ Goniewicz ↔ Pulvers |
|||
3‐HMPMA (3‐hydroxy‐1‐methylpropyl‐mercapturic acid) | ↓↓ Morris | ↓↓ Morris%60 | ↓↓ Morris | |
PMA (phenylmercapturic acid) | ↓↓ Pulvers | |||
MMA (N‐nitrosodimethyamine) | ↔ Pulvers | |||
Nitrosamines | NNAL (4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol) |
↓↓ Cravo ↓↓ Morris |
↓ Goniewicz ↔ Morris ↓↓ Pulvers |
↓↓ Morris |
Metabolites of polyaromatic hydrocarbons | 1‐Hydroxyfluorene | ↑ Goniewicz | ||
3‐, 4‐Hydroxyphenanthrenes | ↑ Goniewicz | |||
2‐Hydroxyfluorene | ↑ Goniewicz | |||
1‐Hydroxypyrene (1‐OHP) | ↓↓ Morris |
↑ Goniewicz ↓↓ Morris |
↓↓ Morris | |
3‐Hydroxyfluorene | ↓ Goniewicz | |||
2‐Hydroxyphenanthrene | ↑ Goniewicz | |||
1‐Hydroxyphenanthrene | ↑ Goniewicz | |||
2‐Naphtol | ↓ Goniewicz | |||
Other known carcinogens | o‐tol (o‐toluidine) | ↓↓ Morris | ↓↓ Morris | ↓↓ Morris |
1‐AN (1‐aminonaphthalene) | ↓↓ Morris | ↓↓ Morris | ↓↓ Morris | |
2‐AN (2‐aminonaphthalene) | ↓↓ Morris | ↓↓ Morris | ↓↓ Morris | |
NNN (N‐nitrosonornicotine) | ↔ Morris | ↔ Morris | ↔ Morris | |
3‐OH B[a]P (3‐hydroxybenxo[a]pyrene) | ↓↓ Morris | ↓↓ Morris | ↓↓ Morris |
Cravo et al. [8] reports data on a subset of participants who were confined for the first week of the study; all complied with study protocols during this period. Data are available in figures only; error bars do not overlap. In Gonieciwz et al. [9], all participants were given an electronic cigarette (EC) at baseline. After 2 weeks, statistically significant declines in 12 of 17 measured biomarkers of exposure to toxicants were observed. Authors also conducted a secondary analysis comparing changes at 2 weeks between those who switched completely to EC and those who used both EC and combustible cigarettes (CC). They give only absolute values (in their Supporting information, Table S3). In Morris et al. [6], all participants exclusively used EC at days 1–9 and then were randomized to three groups from days 10 to 14 (EC, CC and EC + CC); participants were confined for the duration of the study. Authors report between‐group differences and breakdown into two separate samples (studies 1 and 2). Study 1 has the larger sample size so is included in Table 1. Study 2 found consistent directions of effect for all markers. Pulvers et al. [13] assigned all participants to EC and reports median and interquartile ranges (IQRs) for a number of toxic exposures across three groups at 4 weeks: people who switched to EC for at least the first 2 weeks (n = 10); people who switched exclusively for the full 4 weeks (n = 6); and people who used both EC and CC throughout the entire 4‐week period (n = 21). The latter two groups are compared in Table 1. ↓↓ lower point estimate in EC group, with 95% confidence interval (CI)/error bars non‐overlapping; ↓ lower point estimate in EC group, with 95% CI/error bars/P‐value not provided; ↔ CI/error bars overlap; ↑ higher point estimate in EC group, with 95% CI/error bars/P‐value not provided)
Where outcome data were available at multiple time points, we used longest follow‐up.
Screening, data extraction and risk of bias assessments
Two reviewers screened titles and abstracts, and then full texts, using the above criteria. Discrepancies were resolved by discussion or via referral to a third reviewer. We extracted study characteristics and carried out risk‐of‐bias assessments as part of the parent review following Cochrane methods (independently and in duplicate). One reviewer extracted outcome data for this analysis and a second reviewer checked it. We could not formally test for publication bias in this paper, as there were no meta‐analyses with 10 or more studies; the Cochrane review did not detect evidence of publication bias but could not rule it out.
Analysis
Where data allowed, and more than one study reported on an outcome within a given comparison, we conducted inverse variance random‐effects meta‐analyses using RevMan version 5. Where both change from baseline and absolute values at follow‐up were available, we preferred change from baseline. Where studies presented absolute values at follow‐up only, we used these data and subgrouped by absolute values versus change, as recommended by Cochrane. We assessed statistical heterogeneity using the I 2 statistic; where this was above 75%, we considered effect direction when deciding appropriateness of reporting pooled estimates. For outcomes and comparisons where heterogeneity or issues with study reporting precluded meta‐analyses, we synthesized results using effect direction plots, where possible. For all other instances, we reported results narratively.
RESULTS
Of the 49 studies measuring at least one biomarker of exposure identified via our parent Cochrane review, seven provided data relevant to these analyses, together with two new studies identified following publication of the parent review [5, 6]. In total, we include nine studies (n = 1299) in our syntheses (see Table 2 for summary, see Cochrane review for full characteristics [4] and see the Supporting information for flow diagram).
TABLE 2.
Study ID | Device type a | Total N (baseline) | Groups reported | Outcomes available (time‐point) | Data type | Overall risk of bias judgement | Tobacco or EC industry funding? (Y/N) | Country |
---|---|---|---|---|---|---|---|---|
Cobb et al. 2021 [7] | Cartridge | 520 | Covariates include CC and EC use | eCO (3 months) | Absolute values at follow‐up | Low | N | USA |
Cravo et al. 2016 [8] | Cig‐a‐like | 419 | EC and CC | Multiple biomarkers (1 week) | Change from baseline | High | Y | UK |
Goniewicz et al. 2017 [9] | Cig‐a‐like | 22 | EC and dual use | Multiple biomarkers (1 and 2 weeks) | Change from baseline | High | N | Poland |
Ikonomidis et al. 2018 [10] | Not clear | 90 | EC, CC and dual use | eCO (1 month) | Absolute values at follow‐up | High | N | Greece |
Kerr 2020 [5] | Refillable | 55 | EC and abstainers | eCO (12 weeks) | Absolute values at follow‐up | High | N | UK |
McRobbie et al. 2015 [11] | Cig‐a‐like | 40 | EC, CC and dual use | 3‐HPMA (4 weeks) | Change from baseline | High | N | UK |
Morris et al. 2022 [6] | Pod | 79 | EC, CC and dual use | eCO and multiple biomarkers (2 weeks) | Absolute values at follow‐up | High | Y | USA |
Pacifici et al.2015 [12] | Refillable | 34 | EC, CC and dual use | eCO (1, 4, 8 months) | Absolute values at follow‐up | High | N | Italy |
Pulvers et al. 2018 [13] | Refillable | 40 | EC and dual use | Multiple biomarkers (4 weeks) | Change from baseline | High | N | USA |
Based on classification in Hartmann‐Boyce et al. [4]; more information on product characteristics in each study can be found in the Cochrane review. Y/N = yes/no; EC = electronic cigarette; CC = combustible cigarette; eCO = exhaled carbon monoxide; HPMA = hydroxypropylmercapturic acid.
Carbon monoxide
Seven studies provided data on CO. Four of these provided data on eCO which could be meta‐analysed (Figs 1, 2, 3). In pooled analyses, eCO was lower in the EC group than in the dual use or CC groups, with 95% confidence intervals (CIs) excluding no difference in the comparison with CC. eCO was also statistically significantly lower when comparing dual use to CC only (Fig. 3). In all cases, I 2 indicated substantial statistical heterogeneity, but this was driven by magnitude rather than direction of effect, so we present pooled results.
Kerr 2020 was the only study to provide data on abstainers; eCO levels at 12 weeks were the same between the EC group (n = 16) and abstainers (n = 12), at 1 part per million (p.p.m.) [standard deviation (SD) = 1 in both groups] [5]. Abstainers had statistically significantly lower eCO at 12 weeks than the CC group (n = 3) [mean difference (MD) = −18.00 p.p.m., 95% CI = –24.81 to −11.19; analysis not shown).
Cobb et al. reported linear mixed effects models investigating product exposure variables [7]. They reported no statistically significant association between times ECs were used and eCO and a statistically significant positive association between eCO and cigarettes per day, at both 1 and 3 months (P < 0.02; data not reported). In Morris et al. [6], all participants exclusively used EC at days 1–9 and were subsequently randomized to three groups from days 10 to 14 (EC, CC and dual use); participants were confined for the duration of the study [6]. Authors reported between‐group differences in percentage saturation of carboxyhaemoglobin (COHb; a blood measure of CO): at day 14 (n = 14), levels were statistically significantly lower in EC compared to both CC and dual‐use [EC versus CC least squares (LS) MD = −7.13, 95% CI −8.41 to −5.85; EC versus dual‐use LS MD −2.56, 95% CI −3.81 to −1.31]. Levels were also statistically significantly lower in dual use compared to CC (LS MD −4.57, 95% CI −5.90 to −3.25).* Goniewicz et al. provided absolute values without measures of precision for eCO comparing EC to EC + CC at 2 weeks; both groups had reductions from baseline, with the reduction in the EC group reaching statistical significance (EC: 11 to 2 p.p.m., EC + CC 19 to 6 p.p.m.) [9].
Other biomarkers
Five studies reported data on other biomarkers of potential harm; none reported data on abstainers. Only one presented data that could have been meta‐analysed; in McRobbie et al. [11], both EC and dual use groups showed statistically significant reductions in 3‐hydroxy‐1‐methylpropyl‐mercapturic acid (3‐HMPA) at 4 weeks, with no statistically significant between‐group difference in change from baseline (MD = 194.00 ng/g, 95% CI = −502 to 890) [11]. Results throughout studies are presented in an effect direction plot (Table 1). The majority of studies showed absolute reductions from baseline in both EC and EC + CC groups (see Cochrane review and individual papers for more detail); Table 1 reflects between‐group differences.
Of the 13 biomarkers measured when comparing EC versus CC, 12 were lower in EC groups; the one study measuring N‐nitrosonornicotine (NNN) did not detect a statistically significant difference (Table 1) [6]. Of the 25 measured when comparing EC to dual use, results were lower for EC groups for 12 measures (95% CI/error bars non‐overlapping) and dual use for five biomarkers (statistical significance unclear). For the remaining eight measures, single studies did not detect statistically significant differences between groups, or the multiple studies contributing to the outcome had inconsistent results. Only one study provided data comparing dual use to CC; of the 13 biomarkers measured, 12 were lower in EC, with no statistically significant difference detected for NNN [6].
DISCUSSION
In these secondary data analyses, combining data from studies in which people who smoked were provided with ECs, exclusive EC use was associated with lower levels of biomarkers of harm than exclusive use of combustible tobacco or than dual use. This is consistent with other studies and broad scientific consensus that the greatest improvements in health come from ceasing combustible tobacco use in its entirety and that, although not completely without risk, EC are a reduced‐risk alternative [1, 2].
Concerns have been cited by academics and policymakers that using both EC and combustible tobacco may lead to more harm than exclusive combustible tobacco use [2]. Historically, this has been a barrier to research studies and policies that advocate provision of EC to people who smoke as a harm reduction strategy. However, the studies analysed in this review showed no evidence that biomarkers of potential harm increased in people who continued to smoke combustible tobacco while also using EC. In fact, dual use was associated with statistically significant reductions in CO, nitrosamines (mixed evidence), some metabolites of polyaromatic hydrocarbons and some mercapturic acids. However, for all outcomes but CO, data were very limited, and these limitations precluded meta‐analysis. For CO, we observed substantial statistical heterogeneity, but this was driven by the magnitude as opposed to the direction of effect. Concerns have been voiced around dual use leading to greater levels of nicotine exposure than using either e‐cigarettes or conventional cigarettes alone. We do not analyse nicotine exposure here (as it is not necessarily a measure of harm); separate research is needed on this topic.
By their very nature, the data included in these analyses either came from short‐term confinement studies, which are not readily generalizable to real‐world use, or from non‐randomized groupings, which introduce the possibility of unmeasured confounding. However, the findings presented here are consistent with those from the parent Cochrane review, which relied on randomization, and with evidence that if people who smoke obtain nicotine from alternative sources, they smoke less [14]. Evidence is also consistent with that from many observational studies, with reductions in biomarkers observed in EC users compared to people smoking combustible tobacco. A systematic review of nine studies examining the association between nicotine device type and biomarkers of harm found that levels of toxicants were lower in people using EC than in people using combustible cigarettes. The authors deemed this an indication of reduced levels of the following harmful chemicals: butadiene, acrolein, benzene, toluidine, naphthylamine and methylnitrosamines [15]. We encourage studies to collect information on other potential biomarkers that may more clearly characterize EC‐specific health risks that we may be missing. More studies are also needed to quantify how biomarkers differ in abstainers compared to EC groups; only Kerr [5] provided data on abstainers that we could use in our analyses.
A further limitation to our analysis is variation in the products used in these studies, including product types and use characteristics of individuals. Assessing the harmfulness of EC components is difficult because their design and product characteristics vary. Further analyses need to be undertaken examining associations between device type, flavouring and nicotine content on biomarker exposure.
Finally, our main limitation is that we were unable to access individual participant data on exposures. Such data are needed to further examine relationships between EC use patterns, including levels of dual use, and biomarkers of potential harm.
DECLARATION OF INTERESTS
A.R.B., A.T., J.H.B., N.L., I.O.: none to declare. P.H. provided consultancy to and received research funding from Pfizer. C.B. is an investigator on grants and contracts for research on tobacco control from the Health Research Council of NZ, the NHMRC Australia, NZ Ministry of Health and Auckland Council. He has provided consultancy to J&J Japan on NRT products. N.A.R. has received royalties from UpToDate, Inc., for chapters on electronic cigarettes. Outside the topic of e‐cigarettes, she has consulted for and received a research grant from Achieve Life Sciences.
AUTHOR CONTRIBUTIONS
Jamie Hartmann‐Boyce: Conceptualization; data curation; formal analysis; funding acquisition; investigation; methodology. Ailsa R. Butler: Conceptualization; data curation; funding acquisition. Annika Theodoulou: Data curation; investigation. Peter Hajek: Investigation; methodology. Chris Bullen: Investigation; methodology. Nancy A. Rigotti: Investigation; methodology. Nicola Lindson: Conceptualization; data curation; formal analysis; funding acquisition; investigation; methodology.
Supporting information
ACKNOWLEDGEMENTS
This work was supported by an Oxford University Public Policy Challenge Grant, as well as a Tobacco Advisory Group Cancer Research UK Project Grant. It is also supported through core infrastructure funding from the National Institute for Health Research (NIHR) for the Cochrane Tobacco Addiction Review Group. The views and opinions expressed therein are those of the authors and do not necessarily reflect those of the Systematic Reviews Programme, NIHR, National Health Service (NHS) or the Department of Health.
Hartmann‐Boyce J, Butler AR, Theodoulou A, Onakpoya IJ, Hajek P, Bullen C, et al. Biomarkers of potential harm in people switching from smoking tobacco to exclusive e‐cigarette use, dual use or abstinence: secondary analysis of Cochrane systematic review of trials of e‐cigarettes for smoking cessation. Addiction. 2023;118(3):539–545. 10.1111/add.16063
Funding information Cancer Research UK; University of Oxford Policy Challenge Fund; National Institute for Health Research (NIHR)
ENDNOTE
Data reported separately for two samples: study 1 and study 2. These data are from study 1; study 2 data have a smaller sample but are all consistent with study 1 findings for COhB.
REFERENCES
- 1. McNeill A, Brose L, Calder R, Simonavicius E, Robson D. Vaping in England: An Evidence Update Including vaping For Smoking Cessation, February 2021 London, UK: Public Health England; 2021. pp. 1–247. [Google Scholar]
- 2. National Academies of Sciences, Engineering, and Medicine . Public Health Consequences of e‐Cigarettes Washington, DC: National Academies Press; 2018. [PubMed] [Google Scholar]
- 3. Chang JT, Vivar JC, Tam J, Hammad HT, Christensen CH, van Bemmel DM, et al. Biomarkers of potential harm among adult cigarette and smokeless tobacco users in the PATH study wave 1 (2013–2014): a cross‐sectional analysis. Cancer Epidemiol Biomark Prev. 2021;30:1320–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Hartmann‐Boyce J, McRobbie H, Butler AR, Lindson N, Bullen C, Begh R, et al. Electronic cigarettes for smoking cessation. Cochrane Database Syst Rev. 2022;9:CD010216. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Kerr DMI. Studies into the Cardiovascular and Respiratory Effects of Electronic Cigarettes Glasgow, UK: University of Glasgow; 2020. [Google Scholar]
- 6. Morris P, McDermott S, Chapman F, Verron T, Cahours X, Stevenson M, et al. Reductions in biomarkers of exposure to selected harmful and potentially harmful constituents following exclusive and partial switching from combustible cigarettes to myblu™ electronic nicotine delivery systems (ENDS). Intern Emerg Med. 2022;17:397–410. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Cobb CO, Foulds J, Yen M‐S, Veldheer S, Lopez AA, Yingst JM, et al. Effect of an electronic nicotine delivery system with 0, 8, or 36 mg/ml liquid nicotine versus a cigarette substitute on tobacco‐related toxicant exposure: a four‐arm, parallel‐group, randomised, controlled trial. Lancet Respir Med. 2021;9:840–50. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Cravo AS, Bush J, Sharma G, Savioz R, Martin C, Craige S, et al. A randomised, parallel group study to evaluate the safety profile of an electronic vapour product over 12 weeks. Regul Toxicol Pharmacol. 2016;81:S1–S14. [DOI] [PubMed] [Google Scholar]
- 9. Goniewicz ML, Gawron M, Smith DM, Peng M, Jacob P, Benowitz NL. Exposure to nicotine and selected toxicants in cigarette smokers who switched to electronic cigarettes: a longitudinal within‐subjects observational study. Nicotine Tob Res. 2017;19:160–7. 10.1093/ntr/ntw160 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Ikonomidis I, Vlastos D, Kourea K, Kostelli G, Varoudi M, Pavlidis G, et al. Electronic cigarette smoking increases arterial stiffness and oxidative stress to a lesser extent than a single conventional cigarette: an acute and chronic study. Circulation. 2018;137:303–6. [DOI] [PubMed] [Google Scholar]
- 11. McRobbie H, Phillips A, Goniewicz ML, Smith KM, Knight‐West O, Przulj D, et al. Effects of switching to electronic cigarettes with and without concurrent smoking on exposure to nicotine, carbon monoxide, and Acrolein. Cancer Prev Res. 2015;8:873–8. [DOI] [PubMed] [Google Scholar]
- 12. Pacifici R, Pichini S, Graziano S, Pellegrini M, Massaro G, Beatrice F. Successful nicotine intake in medical assisted use of e‐cigarettes: a pilot study. Int J Environ Res Public Health. 2015;12:7638–46. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Pulvers K, Emami AS, Nollen NL, Romero DR, Strong DR, Benowitz NL, et al. Tobacco consumption and toxicant exposure of cigarette smokers using electronic cigarettes. Nicotine Tob Res. 2018;20:206–14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Benowitz NL, Zevin S, Jacob P 3rd. Suppression of nicotine intake during ad libitum cigarette smoking by high‐dose transdermal nicotine. J Pharmacol Exp Ther. 1998;287:958–62. [PubMed] [Google Scholar]
- 15. Akiyama Y, Sherwood N. Systematic review of biomarker findings from clinical studies of electronic cigarettes and heated tobacco products. Toxicol Rep. 2021;8:282–94. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.