Abstract
A method for the retrospective estimation of the individual respiratory intake was tested. The method is based on system dynamics. Subjects were exposed simultaneously to the poorly metabolising solvent tetrachloroethene (PER, perchloroethylene) and the highly metabolising trichloroethene (TRI) at rest, 30, and 65 watt physical exercise. The time courses of the alveolar concentration (Calv) of both PER and TRI were measured. A retrospective estimation of the individual intake of PER could be carried out up to 400 hours after exposure with 10-20% accuracy, irrespective of the level of exercise. The estimates of the intake of TRI are less accurate. The Calv in the 1-15 hours postexposure permits the estimation of the intake of TRI within a mean error of 25% for most subjects. For men the method may be applied up to 48 hours after exposure within 20% error. For women the intake estimates showed a poor accuracy with the use of Calv beyond the day of exposure.
Full text
PDF










Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bassingthwaighte J. B. Blood flow and diffusion through mammalian organs. Science. 1970 Mar 6;167(3923):1347–1353. doi: 10.1126/science.167.3923.1347. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cutler D. J. Numerical deconvolution by least squares: use of prescribed input functions. J Pharmacokinet Biopharm. 1978 Jun;6(3):227–241. doi: 10.1007/BF01312264. [DOI] [PubMed] [Google Scholar]
- Durnin J. V., Womersley J. Body fat assessed from total body density and its estimation from skinfold thickness: measurements on 481 men and women aged from 16 to 72 years. Br J Nutr. 1974 Jul;32(1):77–97. doi: 10.1079/bjn19740060. [DOI] [PubMed] [Google Scholar]
- Engström K., Husman K., Pfäffli P., Riihimäki V. Evaluation of occupational exposure to xylene by blood, exhaled air and urine analysis. Scand J Work Environ Health. 1978 Jun;4(2):114–121. doi: 10.5271/sjweh.2716. [DOI] [PubMed] [Google Scholar]
- Monster A., Regouin-Peeters W., van Schijndel A., van der Tuin J. Biological monitoring of occupational exposure to tetrachloroethene. Scand J Work Environ Health. 1983 Jun;9(3):273–281. doi: 10.5271/sjweh.2409. [DOI] [PubMed] [Google Scholar]
- Opdam J. J. Respiratory input in inhalation experiments. Br J Ind Med. 1989 Mar;46(3):145–156. doi: 10.1136/oem.46.3.145. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Opdam J. J., Smolders J. F. Alveolar sampling and fast kinetics of tetrachloroethene in man. I. Alveolar sampling. Br J Ind Med. 1986 Dec;43(12):814–824. doi: 10.1136/oem.43.12.814. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pedersen P. V. Novel deconvolution method for linear pharmacokinetic systems with polyexponential impulse response. J Pharm Sci. 1980 Mar;69(3):312–318. doi: 10.1002/jps.2600690316. [DOI] [PubMed] [Google Scholar]
- Vaughan D. P., Dennis M. Mathematical basis of point-area deconvolution method for determining in vivo input functions. J Pharm Sci. 1978 May;67(5):663–665. doi: 10.1002/jps.2600670524. [DOI] [PubMed] [Google Scholar]
- Veulemans H., Van Vlem E., Janssens H., Masschelein R. Exposure to toluene and urinary hippuric acid excretion in a group of heliorotagravure printing workers. Int Arch Occup Environ Health. 1979 Sep;44(2):99–107. doi: 10.1007/BF00386743. [DOI] [PubMed] [Google Scholar]
- Wise M. E. Negative power functions of time in pharmacokinetics and their implications. J Pharmacokinet Biopharm. 1985 Jun;13(3):309–346. doi: 10.1007/BF01065658. [DOI] [PubMed] [Google Scholar]
