Abstract
The present study is aimed to assess the adsorptive potential of carbonaceous material for the acyclovir (ACVR) removal from the aquatic environment using batch and fixed-bed processes. In batch mode, the impact of various process conditions (contact time, pH, adsorbent dose, initial ACVR concentration, and temperature) on ACVR adsorption was investigated. Experimental results revealed that Langmuir isotherm and the pseudo-second-order kinetic model adequately represent the ACVR adsorption mechanism, indicating homogeneous adsorption. The process was found exothermic and spontaneous. Thermodynamic studies concluded that adsorption is a result of both physisorption and chemisorption. To understand the dynamic regime for the design of large-scale column studies, experimental data obtained from breakthrough curve were fitted to various analytical kinetic models. Yan model followed by Thomas model demonstrated a greater correlation of breakthrough data, confirming that the results are significant and are in line with Langmuir isotherm and pseudo-second-order kinetic. G-AC exhibits sufficient adsorption capacity for ACVR. Hence, it is concluded that it can be used in a fixed-bed column in continuous mode for the treatment of ACVR-contaminated wastewater.
Graphical abstract
Supplementary Information
The online version contains supplementary material available at 10.1007/s11696-023-02810-7.
Keywords: Granular material, Kinetics, Isotherms, Fixed-bed, Breakthrough curve
Introduction
Over the past few decades, the new strains of life-threatening pandemic viruses, including Nipah virus, severe acute respiratory syndrome (SARS) virus, Middle East respiratory syndrome (MERS), and the most recent one, coronavirus disease (COVID-19), have hit the world. Therefore, the viral infections are of the global concern. Researchers are exploring new promising antibodies, antiviral treatments, and ways to improve the efficacy of existing medications on a laboratory scale (Al-Otaibi et al. 2020; Heidary et al. 2021; Guo et al. 2022). Antiviral drugs have received a lot of attention recently (Nannou et al. 2020; Jain et al. 2013; De Clercq 2004). Acyclovir (ACVR) (Fig. S1), a synthetically prepared purine-based nucleoside analog, shows antiviral activities for the treatment of herpes simplex virus (HSV), hepatitis B, varicella-zoster virus, Epstein-Barr virus, chickenpox, etc. (Nannou et al. 2020; De Clercq 2004). ACVR is usually favored over other drugs because of its low cytotoxicity and high selectivity towards infected cells (Shetti et al. 2020). More than two-thirds of the population is infected by α-HSV (Tognarelli et al. 2019). ACVR reaches drinking water via several routes from domestic/clinic waste, bulk and formulation drug industries, etc. (Gupta et al. 2021). The simultaneous presence of a pertinent virus in living beings and the modest amount of ACVR can render the virus drug-resistant (Jain et al. 2014a). Its presence has been found in industrial effluents, surface water, drinking water, and wastewater influent/effluent stream(s) (Funke et al. 2016; Azuma et al. 2016; Bradley et al. 2014; Peng et al. 2014; Prasse et al. 2011, 2010; Mascolo et al. 2010). Even though ACVR is present at a low concentration ranging from ng/L to μg/L (Azuma et al. 2016; Peng et al. 2014; Bradley et al. 2014), its persistent nature and harmful effects on the aquatic environment necessitate the treatment of contaminated water (Russo et al. 2017). A high therapeutic dose is mainly recommended as it only lasts a brief time in the human body (Saifi et al. 2020). As a result, water contamination and possible environmental issues with the widespread usage of ACVR should be seriously considered. Remediation of industrial wastewater before its discharge is more economical than treating low concentrated large volume of water among preventive routes. Consequently, to prevent the adverse effects of ACVR on the ecosystem, ACVR polluted wastewater must be treated before being discharged.
Adsorption (Hosseini Nasr et al. 2018; Fountouli and Chrysikopoulos 2018; Jain et al. 2014a, 2014b), UV/H2O2 (Liu et al. 2018), catalytic ozonation (Bing et al. 2017), photocatalysis (Wu et al. 2018; Li et al. 2016; Chen et al. 2014), photolysis (Zhou et al. 2015), ozonation (Prasse et al. 2012), and biological treatment techniques (Zhang et al. 2017; Prasse et al. 2011) have been attempted so far till date for the removal of ACVR from wastewater. AOP using oxone has been proven efficient (Liu et al. 2018, 2020); however, the high cost of oxone used in the process makes it un-economical. Oxidation and biodegradation processes lead to more toxic intermediates like COFA and carboxy-ACV (Prasse et al. 2011, 2012). Bio-refractory compounds like ACVR on degradation get converted into more toxic intermediate product(s). For such compounds, adsorption appears to be the most efficient approach, as it does not degrade the compound. Most adsorption studies are carried out in batches, which do not provide precise scale-up information required for practical large-scale treatment. So far column studies on ACVR removal from wastewater have been scarcely reported.
Considering its high surface area and porous structure, granular activated carbon (G-AC) is an efficient adsorbent for ACVR. Hence, it is a viable treatment solution for eliminating ACVR from water. Additionally, G-AC is cost-effective, environmentally benign and easily available and can be used in a variety of treatment systems, including fixed-bed columns. Therefore, the present research was aimed to evaluate the performance of G-AC column for ACVR removal from the synthetically prepared aqueous solution of ACVR. The batch studies were also performed to know the effects of operating parameters on the removal efficiency of ACVR. The breakthrough curves were used to characterize the dynamic response of the fixed-bed column. Effects of initial ACVR concentration, G-AC-bed height, and flow rate on ACVR adsorption were evaluated as part of the column studies along with the analytical model studies. For ACVR-contaminated wastewater, the G-AC fixed-bed column can be effectively applied in continuous operation mode.
Experimental
Chemicals/reagents, solution preparation, and analytical techniques used are described in supplementary file.
Adsorbent characterization
The Brunauer–Emmett–Teller (BET) method was used to determine the specific surface area, pore volume, and pore size distribution of G-AC (Nova Touch LX2 gas sorption analyzer, Quantachrome Instruments). The scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDX) were used to perform morphological characterization of the raw and spent G-AC sample (Nova Nanosem 450, FEITM).
Batch experiments
For determining the maximum removal of ACVR (dosage form, make: Ocuvir, FDC Limited, India) batch adsorption studies were conducted at varying initial concentrations of ACVR, adsorbent dose, pH of the solution, and temperature. A pre-determined amount of G-AC (make: Loba Chemie, India, LR grade) was mixed with 100 mL of synthetically prepared aqueous ACVR solution of known concentration for each group of experiments. Each batch was agitated in an orbital shaker at a fixed temperature and RPM. The solution was filtered after completion of each set, and the residual ACVR concentration was measured in a UV–Vis spectrophotometer.
The adsorption capacity of the G-AC at the time (t min) and the percent removal of ACVR were estimated using the following equations, respectively:
Following equations were used to calculate standard deviation percent (SD%) and root-mean-square error (RMSE):
Kinetic studies
Several kinetic models can test the experimental results and analyze the kinetic mechanism that governs the adsorption rate based on ACVR diffusion in adsorbent particles. The present work used pseudo-first and second-order, Elovich, and intra-particle diffusion kinetic models to evaluate experimental results. A batch size of 100 mL of 100 mg/L concentrated solution was treated with 4 g/L of G-AC at its natural pH (~ 6.8) at 25 °C.
Pseudo-first-order kinetic model deals with the adsorption potential of the adsorbent against an adsorbate. According to the pseudo-second-order kinetic model, physisorption and chemisorption contribute to adsorption (Babas et al. 2021). Elovich model explains chemisorption (Jain et al. 2014a). This model shows the declining adsorption rate with time as the vacant adsorbent sites get occupied by adsorbate molecules and as a result surface coverage increases (Shah et al. 2015). The intraparticle diffusion model explains the adsorption mechanism. It is generally the last step to know about adsorption and type of diffusion within the adsorbent. Model equations used in kinetic studies are summarized in Table S1.
The low C value represents the boundary layer’s minimal influence (diffusional resistance) on adsorption (Shah et al. 2015). The initial rate of adsorption h (mg/g/min) is determined using the following relation:
Equilibrium studies
Adsorption equilibrium studies were carried out to study the adsorption phenomenon and to assess the ACVR interaction behavior with the adsorbent surface. For which solution with varying concentration was treated with 4 g/L of G-AC at its natural pH (~ 6.8) at 25 °C. Temkin, Freundlich, and Langmuir isotherm models were used to examine the equilibrium parameters. Freundlich isotherm reveals the heterogeneous nature of the sorption process (Thiebault et al. 2015; Momčilović et al. 2011). On the other hand, Langmuir isotherm typically shows the homogeneous nature of the adsorption process. It is assumed that adsorbents are mainly composed of fixed vacant sites, each adsorbing single adsorbate particle leading to a monolayer adsorption process (Momčilović et al. 2011). Table S2 provides a summary of the model equations used in isotherm studies.
The nature of adsorption can be determined based on the value of ‘n’ (Momčilović et al. 2011). Favorability of the process was checked using the separating factor (RL):
Thermodynamic studies
To study the temperature dependence of adsorptive removal of ACVR and the spontaneity of the process, thermodynamic studies were conducted. Thermodynamic parameters, namely, Gibbs free energy and heat of adsorption, were also estimated using equations given in Table S3.
Column studies and data analysis
A glass column with an inner diameter of 1.25 cm and a height of 45 cm was used to conduct fixed-bed column studies (Fig. 1). The required flow rate was maintained using a peristaltic pump. Nylon cloth was used at the bottom to stop any adsorbent loss, and glass beads were used on both sides of the column to provide mechanical support to the bed and for uniform distribution of the feed solution preventing channelling. All the experiments were performed at an ambient temperature of 30 ± 2 °C. Effects of various process parameters such as bed height, volumetric flow rate, and inlet ACVR concentration were studied. After predetermined intervals, samples were taken and examined to determine the ACVR concentration. The adsorption capacity and breakthrough time were estimated to assess column performance.
Fig. 1.

Schematic diagram of a fixed-bed adsorption column used for ACVR removal
Fixed-bed analytical models, namely, Thomas, Adams–Bohart, Yoon–Nelson, Clark, and Yan models were used to characterize experimental breakthrough curves. Table S4 summarizes the model equations used in the study.
Results and discussion
Adsorbent characterization
BET surface area and pore volume of G-AC were found to be 470 m2/g and 0.23 cm3/g, respectively. The average pore diameter of G-AC (1.44 nm) suggests the prominent presence of supra-micropores in G-AC (0.7–2 nm) (Thommes 2010). Fig. S2 shows the nitrogen adsorption–desorption isotherm at 77 K and the G-AC pore size distribution curve.
The isotherm is a type IV isotherm, indicating the presence of mesoporous particles. Micro-mesoporous carbons usually feature H4 loops, which are closely attributed to the thin and slit-like pores (Guo et al. 2022). The prominence of micropores causes the volume adsorbed to increase rapidly at lower relative pressure. The pore size distribution estimated by the BJH plot validated the presence of mesopores along with the micropores. Fig. S3 further summarizes the characteristics of G-AC, confirming that it is an efficacious adsorbent.
Higher magnification SEM micrograph (Fig. S3) of the G-AC sample confirmed its porous structure. Additionally, the EDX findings revealed the elemental analysis of G-AC. Fig. S3 clearly demonstrates the adsorption of ACVR on pores of G-AC.
Point of zero charge and pH effect
The liquid-phase pH significantly influences the adsorbent and their ability to adsorb, affecting the binding sites. The effect of pH on ACVR removal using G-AC was examined for 100 mg/L concentrated ACVR solution (Fig. 2a). For a contact time of 75 min, qt increased from 22.75 to 24.62 mg/g on increasing pH from 3 to 7; further increasing pH to 11, qt decreased to 20.25 mg/g. From Fig. 2a, it can be seen that maximum removal was obtained at pH 7. The increased electrostatic affinity between the surface charge of G-AC and ACVR is most likely responsible for the improved adsorption capacity of the system at pH 7. As a result, possibly the G-AC and ACVR surface charges in the aqueous medium are in opposite directions. The point of zero charge has been further used to explain pH influence and to comprehend the interaction between G-AC and ACVR.
Fig. 2.
a pH effect on ACVR removal at a contact time of 75 min, b Point of zero charge of G-AC and ACVR
The pH at which the surface of an adsorbent is believed to behave neutrally is referred to as the point of zero charge (pHZPC). Hence, it is significant to determine the pHZPC before conducting the adsorptive removal experiments involving ionic species adsorption from aqueous environments onto solid surfaces. The pHZPC for G-AC and ACVR is illustrated in Fig. 2b. The results show that the ACVR surface is more basic (pHZPC: 8.2) than G-AC's surface (pHZPC: 6.9). The ACVR and G-AC surfaces are charged positively at pH < pHZPC and negatively at pH > pHZPC. The surface of G-AC shows a negative charge at pH > pHZPC. As the initial pH of the solution is increased, the surplus hydroxide ions in the bulk liquid are generally counterbalanced by the G-AC released hydrogen ions. Furthermore, deprotonation of G-AC lowers the solution’s final pH and results in a net negative charge on the G-AC surface.
As discussed earlier, the G-AC surface is positively charged below pHZPC, as consequence hydrogen ions compete with ACVR cations to reach the surface. The hydrogen ions will gradually surround major active sites on the G-AC surface. At pH < 7, both G-AC and ACVR are positively charged which repelled from each other. As such, ACVR molecules were not effectively adsorbed on G-AC. Similar patterns for pHZPC values for G-AC and ACVR are reported in the literature (Borah et al. 2008).
Effect of adsorbent dose
Experiments were carried out at varying doses of adsorbents ranging from 1 to 4 g/L at 25 °C for 2 h to investigate the effects of the G-AC dose on the ACVR removal efficiency (Fig. 3).
Fig. 3.

Impact of varying adsorbent dose on ACVR removal
When adsorbent dose was increased from 1 to 4 g/L, there was a polynomial increase in the removal of ACVR from 39.7 to 95.2%. It can be seen from Fig. 3 that there was a continuous rise in the percent removal of ACVR, but 4 g/L was taken as optimum as already 95% removal was being achieved with this dose. A reduction of 95.2% in ACVR concentration indicates that almost all of the vacant-active sites on the adsorbent surface are occupied at this point, and increasing the adsorbent dosage beyond this point will not be cost-effective.
Impact of contact time
At natural pH (~ 6.8), the impact of contact time on ACVR adsorption by G-AC was examined for 105 min. Figure 4a depicts the performance of adsorbents for the removal of ACVR with contact time.
Fig. 4.
a Impact of Contact time (initial ACVR concentration: 100 mg/L) and b Impact of ACVR initial concentration on percent removal at equilibrium
The polynomial increase in percent removal was observed on increasing the contact time of adsorbent and ACVR. More than 50% of the removal was achieved within the initial 30 min using G-AC. Initially, the removal rate was rapid; however slow reduction was observed later. This could be due to more unoccupied sites on adsorbent are available at the initial stage with a high driving force which decreases with time and active sites also diminishes. Finally, for an initial ACVR concentration of 100 mg/L system reached the state of saturation at 75 min.
Adsorption kinetics
The adsorption kinetics of ACVR onto G-AC using pseudo-first- and -second-order, Elovich, and intra-particle diffusion kinetic models is depicted in Fig. S4. Table 1 summarizes the values of regression coefficients obtained and other kinetic parameters of ACVR adsorption.
Table 1.
Parameters for various kinetic models for ACVR removal
| Kinetic model | Parameter | Values |
|---|---|---|
| Pseudo-first-order model | qe,exp (mg/g) | 24.62 |
| k1 (min−1) | 0.04 | |
| qe,cal (mg/g) | 8.98 | |
| R2 | 0.9899 | |
| SD% | 8.1% | |
| RMSE | 7.82 | |
| Pseudo-second-order model | k2 (g/mg/min) | 0.01 |
| qe,cal (mg/g) | 25.58 | |
| R2 | 0.9991 | |
| h (mg/g/min) | 7.20 | |
| SD% | 0.02% | |
| RMSE | 0.43 | |
| Elovich kinetic model | α (mg/g/min) | 296.61 |
| β (g/mg) | 0.36 | |
| R2 | 0.9771 | |
| Intraparticle diffusion model | Kd (mg/g/min0.5) | 1.12 |
| C (mg/g) | 15.48 | |
| R2 | 0.9579 |
The significance of studying the adsorption kinetics of ACVR onto G-AC using different kinetic models lies in understanding the rate and mechanism of the adsorption process. The comparison of the results obtained from different models can help determine the most suitable kinetic model for describing the adsorption process and provide insights into the mechanism of adsorption. Kinetic data obtained in the present study are significant and indicate that the adsorption process satisfies pseudo-second-order kinetic model.
The smaller difference in the equilibrium amount adsorbed between experimental and calculated values confirms the pseudo-second-order behavior of the process (Table 1). Moreover, the slightly lower correlation coefficient (R2) also shows the inappropriateness of the pseudo-first-order kinetic model. The adsorption kinetics of numerous bio-refractory pollutant-adsorbent systems have exhibited comparable kinetic results (Babas et al. 2021; Fountouli and Chrysikopoulos 2018; Shah et al. 2015; Fan et al. 2012).
If the value of C is not zero for any adsorption process, the intraparticle diffusion is not the sole controlling mechanism (Fan et al. 2012). Thus, it can be concluded that during ACVR sorption on G-AC, film and intraparticle diffusion occur simultaneously (Shah et al. 2015; Jain et al. 2014a).
Influence of ACVR initial concentration
It is vital to investigate the effect of the initial concentration of the adsorbate on the sorption rate for effective adsorption. The variation of the adsorptive removal efficiency of G-AC at different initial concentrations of ACVR (100–400 mg/L) is presented in Fig. 4b.
It is evident from Fig. 4b that as the drug concentration rise, so does the quantity of adsorbed ACVR. This could be because the difference between available adsorbent sites and the initial number of ACVR molecules is high at higher concentrations. Therefore, an initial concentration of 100 mg/L ACVR was used in the present study; moreover, further change in percent removal was significantly less. Additionally, it is common that the lower the initial adsorbate concentration, the higher removal efficiency while the other experimental conditions were kept constant.
Adsorption isotherms
Fig. S5 depicts the adsorption isotherms (Freundlich, Langmuir, and Temkin) and Table 2 shows the isotherm parameters for the ACVR adsorption onto G-AC.
Table 2.
Isotherm parameters for ACVR sorption
| Particulars | Parameter | Value |
|---|---|---|
| Freundlich isotherm | KF (mg/g)/(L/mg)n | 24.51 |
| n | 2.37 | |
| R2 | 0.9293 | |
| SD% | 12.69 | |
| RMSE | 8.72 | |
| Langmuir isotherm | Qm (mg/g) | 105.26 |
| KL (L/mg) | 0.21 | |
| R2 | 0.9981 | |
| SD% | 3.46% | |
| RMSE | 2.35 | |
| RL | 0 < RL < 1 | |
| Temkin isotherm | AT (L/g) | 2.10 |
| bT | 109.93 | |
| BT (mg/g) | 22.54 | |
| R2 | 0.9831 | |
| RMSE | 16.865 |
The highest R2 value confirms the Langmuir adsorption isotherm model’s good fit to the experimental data. In the present work, the value of RL was found 0.045 indicating the ACVR adsorption to be a favorable process. Furthermore, the low RL value suggests that ACVR interaction with adsorbents is strong (Fan et al. 2012). The value of the heterogeneity factor also confirms the favorability of the process, and the process follows the Langmuir isotherm (0 < 1/n < 1) (Fytianos et al. 2000). It also signifies that monolayer chemisorption occurs with uniform adsorptive sites and energy (Thiebault et al. 2015). The increase in adsorption capacity indicates weak interaction between adsorbed ACVR molecules (Hasnain Isa et al. 2007). Similar results are reported for numerous pollutant-adsorbent systems (Babas et al. 2021; Thiebault et al. 2015; Fan et al. 2012).
Thermodynamic studies
Adsorption studies at varying temperatures were conducted to examine the influence of temperature on ACVR uptake (Fig. S6). Table 3 highlights the thermodynamic parameters for ACVR adsorption onto G-AC. Both 1/T and ln (qe/Ce) values decrease with rise in temperature, indicating that the adsorption process is exothermic. Following equations were used to calculate change in Gibbs free energy,
Table 3.
Thermodynamic parameters for ACVR adsorption onto G-AC
| Temperature (°C) | ∆H0 (kJ/mol) | ∆S0 (kJ/mol/K) | ∆G0 (kJ/mol) |
|---|---|---|---|
| 25 | − 56.88 | − 0.168 | − 6.93 |
| 30 | − 6.04 | ||
| 35 | − 4.59 | ||
| 40 | − 4.19 | ||
| 45 | − 3.38 | ||
| 50 | − 2.64 | ||
| 55 | − 1.78 |
Combining above equations,
The heat of adsorption was negative, indicating exothermic nature for ACVR sorption onto G-AC. ACVR is soluble in water and may lose some of its hydration molecules, releasing heat. The spontaneous physisorption process is further established by the ∆G° value (0–20 kJ/mol) (Khadhri et al. 2019) (Table 3). Further, as the temperature rises from 25 to 55 °C, ∆G° increases, indicating that the feasibility of the process declines with temperature rise (Khadhri et al. 2019; Malkoc et al. 2006). The favorability of the process was also confirmed with the value of RL reported in Table 2. Decrease in K0 value with temperature also confirms the exothermic nature of ACVR adsorption (Fountouli and Chrysikopoulos 2018). Moreover, the value of ∆S° was negative, showing that the ACVR adsorption was enthalpy driven (Fountouli and Chrysikopoulos 2018). Several pollutant-adsorbent systems have also produced similar results (Thiebault et al. 2015; Jain et al. 2014a). Since the Langmuir isotherm supports chemisorption while ∆G° (0–20 kJ/mol) supports physisorption. This was further clarified using ∆H° which indicates physisorption is being accompanied by chemisorption. This concludes that the adsorption of ACVR onto G-AC is in the transition phase from physisorption to chemisorption.
Effect of volumetric flow rate
The breakthrough response for ACVR adsorption was examined at various volumetric flow rates (Fig. 5). As the volumetric flow rate rises from 3.1 to 3.8 mL/min, the breakthrough times at Ct/C0 = 0.1 shifted to 75 min from 120 min. It can be explained as at a high flow rate, the contact time between the G-AC and ACVR reduces, limiting the bed's adsorption capacity and processing times (Biswas and Mishra 2015; Darweesh and Ahmed 2017b). Furthermore, at a higher flow rate, the breakthrough curve shifts near the origin, become steeper, and reaches saturation more quickly.
Fig. 5.

Effect of volumetric flow rate
Figure 5 demonstrates that Ct/C0 increased from 0.12 to 0.32 at 3.1 and 4.5 mL/min flow rates, respectively, after 2 h. ACVR has more time to permeate through bed when the flow rate decreases, resulting in an increased column uptake. Likewise, higher volumetric flow rate diminishes the thickness of fluid film surrounding the sorbent particles, reducing mass transfer resistance and a quick increase in mass transfer (Liao et al. 2013). Similar trends have been reported in previous studies for the adsorptive removal of various pharmaceutical drugs (Gupta and Garg 2019; Darweesh and Ahmed 2017a; Liao et al. 2013).
Effect of bed height
Figure 6 presents breakthrough curves data at varying bed depths for a 200 mg/L concentrated solution and a volumetric flow rate of 3.1 mL/min.
Fig. 6.

Effect of bed height
The breakthrough time and exhaustion time decreased on reducing bed depth, moving the breakthrough curve towards the origin, as shown in Fig. 6. Also, Ct/C0 for a short-fixed bed rises fast than for a long bed. Breakthrough concentrations (Ct/C0 = 0.1) were attained at contact times of 2 h and 7 h for 3.5 and 12 cm of bed heights, respectively. Ct/C0 varied from 0.59 and 0.11 at bed heights of 3.5 and 12 cm, respectively, after 7 h. With a greater bed height, more adsorbent load is used resulting in more adsorption sites and a longer contact time to attain 100% saturation (Baral et al. 2009). Furthermore, as the bed height rises, the adsorbate has considerable time for diffusion through the pores of the adsorbent, increasing the overall adsorbed amount and ACVR removal efficiency (Reynel-Avila et al. 2015). Similar results for the adsorption of several pharmacological drugs have been reported in the literature (Gupta and Garg 2019; Darweesh and Ahmed 2017a; Liao et al. 2013).
Impact of inlet ACVR concentration
Figure 7 shows that the inlet ACVR concentration considerably impacts the breakthrough curve.
Fig. 7.

Effect of inlet ACVR concentration
Time to reach breakthrough and exhaustion increased as the inlet ACVR concentration decreased. The breakthrough curve moved away from the origin at lower inlet concentration. Ct/C0 varied from 0.03 to 0.10 at inlet concentrations of 200 and 300 mg/L, respectively, at a contact time of 90 min. This phenomenon may be explained by an increase in the sorption rate and the mass transfer driving force across the liquid film, which causes the fixed bed to saturate more quickly. These study results on the impact of inflow concentration on breakthrough curves concur with other bio-refractory compounds reported literature studies (Darweesh and Ahmed 2017a; Biswas and Mishra 2015).
Thomas model
The Thomas model investigates how maximum column uptake and breakthrough curves are evaluated. This model emphasizes that the process follows Langmuir kinetics, and there is no axial dispersion (Cruz et al. 2020; Baral et al. 2009). It is also derived under the presumption that the rate of the driving force is subject to reversible 2nd order kinetics. It is advisable for the adsorption system when there is essentially no resistance to internal diffusion (Han et al. 2009; Baral et al. 2009). Table 4 provides more information on the obtained kTH, qTH, and R2 values at various process conditions (Fig. S7).
Table 4.
Parameters of kinetic analytical models for ACVR adsorption for different sets of process conditions
| Process conditions | Z (cm) | 3.5 | 3.5 | 8 | 12 | 3.5 | 3.5 | 3.5 |
| Q (mL/min) | 3.8 | 4.5 | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | |
| C0 (mg/L) | 200 | 200 | 200 | 200 | 200 | 300 | 400 | |
| Thomas model | kTH × 10−5 (L/mg/min) | 3.15 | 4.45 | 2.20 | 1.35 | 2.90 | 1.97 | 1.57 |
| qTH (mg/g) | 211.81 | 199.54 | 248.98 | 242.69 | 224.91 | 302.20 | 312.93 | |
| R2 | 0.92 | 0.94 | 0.90 | 0.99 | 0.91 | 0.89 | 0.90 | |
| Yoon–Nelson model | kYN (min−1) | 0.0063 | 0.0089 | 0.0044 | 0.0027 | 0.0058 | 0.0059 | 0.0063 |
| τ (min) | 278.70 | 221.71 | 803.16 | 1174.33 | 362.76 | 324.95 | 252.36 | |
| τexp (min) | 270 | 210 | 660 | 1200 | 360 | 330 | 210 | |
| R2 | 0.92 | 0.94 | 0.90 | 0.99 | 0.91 | 0.89 | 0.90 | |
| Adams–Bohart model | kBA × 10−5 (L/mg/min) | 1.70 | 2.25 | 1.60 | 0.95 | 1.75 | 1.13 | 0.82 |
| N0 (mg/L) | 7733.02 | 7393.39 | 5684.98 | 5538.09 | 7182.78 | 10388.09 | 12462.19 | |
| R2 | 0.81 | 0.80 | 0.85 | 0.99 | 0.82 | 0.77 | 0.77 | |
| Clark model | r (min−1) | 0.0071 | 0.01 | 0.0054 | 0.0032 | 0.0067 | 0.0068 | 0.0072 |
| A | 11.89 | 16.26 | 115.75 | 68.27 | 18.30 | 14.71 | 9.94 | |
| R2 | 0.90 | 0.92 | 0.88 | 0.99 | 0.89 | 0.87 | 0.89 | |
| Yan model | kY (L/mg/min) | 0.030 | 0.040 | 0.035 | 0.032 | 0.027 | 0.015 | 0.010 |
| q0 (mg/g) | 0.756 | 0.892 | 0.307 | 0.205 | 0.617 | 0.929 | 1.239 | |
| R2 | 0.99 | 0.99 | 0.96 | 0.96 | 0.98 | 0.94 | 0.99 |
It indicates agreement between the Thomas model and experimental data for breakthrough curves (0.89 > R2 > 0.99), signifying the good fit of the model for ACVR adsorption on G-AC. Since the experimental data fitted the Thomas model well, film and intraparticle diffusion are not expected to be the limiting step. But, the limiting adsorption stage is the solid surface mass transfer (de Franco et al. 2017; Baral et al. 2009). Flow resistance increases on increasing bed height, resulting in decreased mass transfer effect, causing a decrement in kTH and increase in qTH (Du et al. 2018). On the other hand, increasing flow rate will result in insufficient contact time between ACVR and G-AC for fixed number of vacant sites causing decrease in the value of qTH whereas increase in kTH (Du et al. 2018; Chen et al. 2012). An increased driving force achieved a higher column performance at higher ACVR concentration. The results are consistent with the literature (Kumari et al. 2021; Pholosi et al. 2020; Chen et al. 2012; Baral et al. 2009).
Table 5 compares the value of qTH of G-AC obtained in the present study with the literature. The maximum adsorption capacity of G-AC (qTH) in the present study has been found to be higher than other adsorbate-adsorbent systems.
Table 5.
Comparison of qTH with values reported in literature
| Adsorbent | Adsorbate | Models investigated* | qTH (mg/g) | References |
|---|---|---|---|---|
| G-AC | ACVR | TH, YN, AB, Clark, Yan | 224.91 | Present study |
| Thermally activated weed Salvinia Cucullata | Cr (VI) | TH, YN, AB | 159.20 | Baral et al. (2009) |
| Activated carbon from date stones | Ciprofloxacin | TH, YN, AB | 2.09 | Darweesh and Ahmed (2017b) |
| Activated carbon from date stones | Norfloxacin | TH, YN, AB | 1.99 | Darweesh and Ahmed (2017b) |
| Activated carbon from date stones | Levofloxacin | TH, YN, AB | 2.56 | Darweesh and Ahmed (2017a) |
| Activated carbon | Amoxicillin | TH, AB, Yan | 11.48 | de Franco et al. (2017) |
| Activated sludge derived activated carbon | Ciprofloxacin | TH, YN, AB | 14.00 | Gupta and Garg (2019) |
| Carboxyl-modified jute fiber | Cu (II) | TH, YN | 42.21 | Du et al. (2018) |
| Activated carbon from date palm petiole | Indigo carmine | TH, YN, AB, Yan | 48.88 | Khadhri et al. (2019) |
| Bone char | Crystal violet | TH, Yan | 22.44 | Cruz et al. (2020) |
| Magnetic pine cone composite | Cr (VI) | TH, YN, AB | 33.08 | Pholosi et al. (2020) |
| Acid modified alumina | Fluoride | TH, YN, Clark, Yan | 19.12 | Kumari et al. (2021) |
*TH Thomas model, YN Yoon–Nelson model, AB Adams–Bohart model
Yoon–Nelson model
This model presupposes that the decline in the adsorption rate of each adsorbate molecule is proportionally related to the adsorbate adsorption probability and probability of its breakthrough capacity onto the adsorbent (Gupta and Garg 2019; Yoon and Nelson 1984). This model is significant in determining the nature of the adsorption process with its exhaustion time for a given concentration (Gupta and Garg 2019). The estimated values of various Yoon–Nelson model parameters are summarized in Table 4. It shows the strong correlation between experimental data and the Yoon–Nelson model (0.89 < R2 < 0.99) (Table 4 and Fig. S8), indicating the adequacy of the model. According to the Yoon–Nelson model's fitting parameters, an increase in the initial concentration of ACVR leads to the enhancement of KYN value and reduction in τ value. It might be because the G-AC in the column quickly saturates.
On the contrary, as the bed height was raised, the KYN declined and the value of τ improved. This is because the amount of adsorbent increases as the height of the bed rises. Other studies have also reported consistent patterns (Kumari et al. 2021; Demarchi et al. 2015).
Adams–Bohart model
The Adams–Bohart model is based on the premise that equilibrium is not instantaneous and primarily concerned with the surface reaction theory. Therefore, rate of adsorption is related to adsorbate concentration in the solution and the adsorbent’s residual capacity (Malkoc et al. 2006). The initial segment of the breakthrough curve has been described by Adams–Bohart model in several previous studies. However, in the current study, the model has been fitted from the beginning of breakthrough curve to final point (Fig. S9). The estimated model parameters and R2 values for various process conditions are provided in Table 4. Table 4 shows that the values of kBA were found to increase with increasing flow rate but deceased with increasing initial ACVR concentration and bed height. At most of the process conditions, the correlation coefficient is low (< 0.86); hence, the correlation between experimental data and the Adams–Bohart model is not strong. Other investigations have also reported similar results. (Biswas and Mishra 2015; Liao et al. 2013).
Clark model
The Clark model anticipates the breakthrough curve’s behavior by studying mass transfer and adsorption equilibrium (Kumari et al. 2021; Han et al. 2009). It assumes that the flow in the column is plug flow type, and the Freundlich isotherm is followed by mass transfer occurring in the column (Patel 2019). Fig. S10 shows the linear curve fitting of breakthrough curves using the Clark model. Table 4 presents the value of Clark model parameters, ‘A’ and ‘r’, at different process conditions. On increasing the bed height of the column, the value of r decreased. Further, r increases with flow rate and inlet ACVR concentration. At almost all process conditions, the value of correlation coefficient is in the range (0.87–0.92), indicating relatively poor fit of the Clark model. Similar results have been obtained earlier (Han et al. 2009).
Yan model
It has been reported earlier that, at absurdly short and very long operation times, the Yan model is proposed to reduce the inaccuracy that occurs from using the Thomas model (Maheshwari and Gupta 2016; Yan et al. 2001). Figure 8 illustrates the linear curve fitting of experimental data using the Yan model for various parameters.
Fig. 8.
Yan model for varying a flow rate, b bed height, and c initial ACVR concentration
The findings indicate a good agreement between the experimental data and the model, with R2 values in the ranges of 0.94–0.99 (Table 4). The value of kY increases on increasing flow rate, while decreases with concentration. According to Table 4, the estimated adsorption capacity values from the Thomas and Yan model are of the same order. However, it is observed that the Yan model is better at evaluating adsorption capacity of the bed than the Thomas model which estimates inflated value (Kumari et al. 2021; Cruz et al. 2020). Other works of literature have also reported similar overall results (Kumari et al. 2021; Cruz et al. 2020).
Comparison of breakthrough curve fitting
Thomas and Yan models suggest that external and intraparticle diffusion are not controlling, but the solid surface mass transfer (surface diffusion) is the limiting step in the adsorption process. (Kumari et al. 2021; de Franco et al. 2017; Han et al. 2009). Adams–Bohart model demonstrated the lowest average R2 (0.82) signifying the weak correlation between experimental data and the model. Although, the average value of correlation coefficient for Clark model is 0.90. The poor fit of the Clark model for breakthrough data is in accordance with the batch study results, which fitted well to Langmuir isotherm. The inability of Adams–Bohart and Clark models to accurately predict the removal of ACVR by G-AC can be attributed to two factors: the existence of numerous mechanisms (possibly, adsorption and ion exchange) that contribute to ACVR adsorption onto G-AC and the significant involvement of mass transfer resistance in the removal of ACVR using G-AC (Dorado et al. 2014).
The Yan model exhibited the highest average R2 (0.98), indicating the best fit of the model and the experimental data. As noted in the previous section, batch ACVR adsorption onto G-AC was found to follow the pseudo-second-order kinetic model and Langmuir isotherm model. Both of these conclusions have been supported by Yan models applied to fixed-bed column studies.
Continuous column studies of ACVR adsorption on any of the adsorbent has been scarcely reported. Therefore, qTH value signifying adsorption capacity of the adsorbent obtained using Thomas model has been compared for the present study with results reported in literature for other adsorbate-adsorbent systems.
Conclusions
Antiviral pollutants, such as ACVR have been found in groundwater, surface water, and industrial wastewater. Their inadequate removal through conventional treatment is a significant challenge in water reuse. G-AC has proven to be an efficient adsorbent for the ACVR removal from aqueous solutions. The characterization showed the morphology and surface area of G-AC along with the ACVR adsorption (SEM, BET, and EDX).
Batch experiments showed that Langmuir isotherm adequately represents the equilibrium data indicating monolayer chemisorption is the predominant mechanism for ACVR adsorption onto G-AC. Pseudo-second-order kinetic model predicted the adsorption process. Negative values of heat of adsorption and Gibbs free energy indicated exothermic nature of the process and confirmed the process feasibility. The process of adsorption was found to be physisorption accompanied by chemisorption. The feasibility of adsorption decreases with increase in temperature. The adsorption process slightly decreases the randomness of molecules at the solid/liquid interface and is enthalpy driven.
The fixed-bed column experimental data were fitted to different analytical models. The Yan model fitted the data best, followed by the Thomas model confirming the pseudo-second-order kinetics and Langmuir isotherm. Adsorption capacity of the fixed bed of G-AC estimated using Thomas model indicated that the adsorption capacity is excellent for ACVR when compared to other adsorbate-adsorbent system studied in literature. For ACVR-contaminated wastewater, the G-AC fixed-bed column can be effectively applied in continuous operation mode.
The current research's findings will be useful for small volumes of wastewater generated by ACVR manufacturing units. ACVR removal from the industrial effluents released by bulk manufacturing and formulation industries can be achieved in a continuous flow unit using a packed bed of a commercial adsorbent. This will prevent the entry of strong inhibitory substances, like ACVR, into the biological wastewater treatment units, which may inhibit the activity of the micro-organism that treat the soluble organics.
Supplementary Information
Below is the link to the electronic supplementary material.
Acknowledgements
No specific grant was given to this research by funding organizations in the public, commercial, or not-for-profit sectors. However, one of the authors (AG) expresses her gratitude to Malaviya National Institute of Technology (MNIT) Jaipur and Ministry of Education, Govt. of India for providing the financial support in the form of Institute Fellowship for carrying out Ph. D. research work. The authors also wish to thank the Material Research Centre (MRC), MNIT Jaipur, for carrying out SEM, EDX and BET analysis of the samples.
Declarations
Conflict of interest
The authors report no declarations of interest.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- Al-Otaibi JS, Mary YS, Thomas R, Kaya S. Detailed electronic structure, physico-chemical properties, excited state properties, virtual bioactivity screening and SERS analysis of three guanine based antiviral drugs valacyclovir HCl hydrate, acyclovir and ganciclovir. Polycycl Aromat Compd. 2020;42:1260–1270. doi: 10.1080/10406638.2020.1773876. [DOI] [Google Scholar]
- Azuma T, Arima N, Tsukada A, Hirami S, Matsuoka R, Moriwake R, Ishiuchi H, Inoyama T, Teranishi Y, Yamaoka M, Mino Y, Hayashi T, Fujita Y, Masada M. Science of the Total Environment Detection of pharmaceuticals and phytochemicals together with their metabolites in hospital effluents in Japan, and their contribution to sewage treatment plant influents. Sci Total Environ. 2016;548–549:189–197. doi: 10.1016/j.scitotenv.2015.12.157. [DOI] [PubMed] [Google Scholar]
- Babas H, Kaichouh G, Khachani M, Karbane ME, Chakir A, Guenbour A, Bellaouchou A, Warad I, Zarrouk A. Equilibrium and kinetic studies for removal of antiviral sofosbuvir from aqueous solution by adsorption on expanded perlite: experimental, modelling and optimization. Surf Interfaces. 2021;23:100962. doi: 10.1016/j.surfin.2021.100962. [DOI] [Google Scholar]
- Baral SS, Das N, Ramulu TS, Sahoo SK, Das SN, Chaudhury GR. Removal of Cr(VI) by thermally activated weed Salvinia cucullata in a fixed-bed column. J Hazard Mater. 2009;161:1427–1435. doi: 10.1016/j.jhazmat.2008.04.127. [DOI] [PubMed] [Google Scholar]
- Bing J, Hu C, Zhang L. Enhanced mineralization of pharmaceuticals by surface oxidation over mesoporous γ-Ti-Al2O3 suspension with ozone. Appl Catal B Environ. 2017;202:118–126. doi: 10.1016/j.apcatb.2016.09.019. [DOI] [Google Scholar]
- Biswas S, Mishra U. Continuous fixed-bed column study and adsorption modeling: Removal of lead ion from aqueous solution by charcoal originated from chemical carbonization of rubber wood sawdust. J Chem. 2015 doi: 10.1155/2015/907379. [DOI] [Google Scholar]
- Borah D, Satokawa S, Kato S, Kojima T. Surface-modified carbon black for As(V) removal. J Colloid Interface Sci. 2008;319:53–62. doi: 10.1016/j.jcis.2007.11.019. [DOI] [PubMed] [Google Scholar]
- Bradley PM, Barber LB, Duris JW, Foreman WT, Furlong ET, Hubbard LE, Hutchinson KJ, Keefe SH, Kolpin DW. Riverbank filtration potential of pharmaceuticals in a wastewater-impacted stream. Environ Pollut. 2014;193:173–180. doi: 10.1016/j.envpol.2014.06.028. [DOI] [PubMed] [Google Scholar]
- Chen S, Yue Q, Gao B, Li Q, Xu X, Fu K. Adsorption of hexavalent chromium from aqueous solution by modified corn stalk: a fixed-bed column study. Bioresour Technol. 2012;113:114–120. doi: 10.1016/j.biortech.2011.11.110. [DOI] [PubMed] [Google Scholar]
- Chen J, Luo H, Shi H, Li G, An T. Anatase TiO2 nanoparticles-carbon nanotubes composite: optimization synthesis and the relationship of photocatalytic degradation activity of acyclovir in water. Appl Catal A Gen. 2014;485:188–195. doi: 10.1016/j.apcata.2014.08.004. [DOI] [Google Scholar]
- Cruz MAP, Guimarães LCM, da Costa Júnior EF, Rocha SDF, da Mesquita PL. Adsorption of crystal violet from aqueous solution in continuous flow system using bone char. Chem Eng Commun. 2020;207:372–381. doi: 10.1080/00986445.2019.1596899. [DOI] [Google Scholar]
- Darweesh TM, Ahmed MJ. Batch and fixed bed adsorption of levofloxacin on granular activated carbon from date (Phoenix dactylifera L.) stones by KOH chemical activation. Environ Toxicol Pharmacol. 2017;50:159–166. doi: 10.1016/j.etap.2017.02.005. [DOI] [PubMed] [Google Scholar]
- Darweesh TM, Ahmed MJ. Adsorption of ciprofloxacin and norfloxacin from aqueous solution onto granular activated carbon in fixed bed column. Ecotoxicol Environ Saf. 2017;138:139–145. doi: 10.1016/j.ecoenv.2016.12.032. [DOI] [PubMed] [Google Scholar]
- De Clercq E. Antivirals and antiviral strategies. Nat Rev Microbiol. 2004;2:704–720. doi: 10.1038/nrmicro975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- de Franco MAE, de Carvalho CB, Bonetto MM, de Soares RS, Féris LA. Removal of amoxicillin from water by adsorption onto activated carbon in batch process and fixed bed column: kinetics, isotherms, experimental design and breakthrough curves modelling. J Clean Prod. 2017;161:947–956. doi: 10.1016/j.jclepro.2017.05.197. [DOI] [Google Scholar]
- Demarchi CA, Debrassi A, Magro JD, Nedelko N, Ślawska-Waniewska A, Dłuzewski P, Greneche JM, Rodrigues CA. Adsorption of Cr(VI) on crosslinked chitosan-Fe(III) complex in fixed-bed systems. J Water Process Eng. 2015;7:141–152. doi: 10.1016/j.jwpe.2015.05.003. [DOI] [Google Scholar]
- Dorado AD, Gamisans X, Valderrama C, Solé M, Lao C. Cr(III) removal from aqueous solutions: a straightforward model approaching of the adsorption in a fixed-bed column. J Environ Sci Heal Part A Toxic/hazardous Subst Environ Eng. 2014;49:179–186. doi: 10.1080/10934529.2013.838855. [DOI] [PubMed] [Google Scholar]
- Du Z, Zheng T, Wang P. Experimental and modelling studies on fixed bed adsorption for Cu(II) removal from aqueous solution by carboxyl modified jute fiber. Powder Technol. 2018;338:952–959. doi: 10.1016/j.powtec.2018.06.015. [DOI] [Google Scholar]
- Fan L, Luo C, Li X, Lu F, Qiu H, Sun M. Fabrication of novel magnetic chitosan grafted with graphene oxide to enhance adsorption properties for methyl blue. J Hazard Mater. 2012;215–216:272–279. doi: 10.1016/j.jhazmat.2012.02.068. [DOI] [PubMed] [Google Scholar]
- Fountouli TV, Chrysikopoulos CV. Adsorption and thermodynamics of pharmaceuticals, acyclovir and fluconazole, onto quartz sand under static and dynamic conditions. Environ Eng Sci. 2018;35:909–917. doi: 10.1089/ees.2017.0499. [DOI] [Google Scholar]
- Funke J, Prasse C, Ternes TA. Identification of transformation products of antiviral drugs formed during biological wastewater treatment and their occurrence in the urban water cycle. Water Res. 2016;98:75–83. doi: 10.1016/j.watres.2016.03.045. [DOI] [PubMed] [Google Scholar]
- Fytianos K, Voudrias E, Kokkalis E. Sorption-desorption behaviour of 2,4-dichlorophenol by marine sediments. Chemosphere. 2000;40:3–6. doi: 10.1016/S0045-6535(99)00214-3. [DOI] [PubMed] [Google Scholar]
- Guo Z, Zhang Y, Gan S, He H, Cai N, Xu J, Guo P, Chen B, Pan X. Effective degradation of COVID-19 related drugs by biochar-supported red mud catalyst activated persulfate process: Mechanism and pathway. J Clean Prod. 2022;340:130753. doi: 10.1016/j.jclepro.2022.130753. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gupta A, Garg A. Adsorption and oxidation of ciprofloxacin in a fixed bed column using activated sludge derived activated carbon. J Environ Manag. 2019;250:109474. doi: 10.1016/j.jenvman.2019.109474. [DOI] [PubMed] [Google Scholar]
- Gupta A, Vyas RK, Gupta AB. Occurrence of acyclovir in the aquatic environment, its removal and research perspectives: a review. J Water Process Eng. 2021;39:101855. doi: 10.1016/j.jwpe.2020.101855. [DOI] [Google Scholar]
- Han R, Wang Yu, Zhao X, Wang Yuanfeng Xie F, Cheng J, Tang M. Adsorption of methylene blue by phoenix tree leaf powder in a fixed-bed column: experiments and prediction of breakthrough curves. Desalination. 2009;245:284–297. doi: 10.1016/j.desal.2008.07.013. [DOI] [Google Scholar]
- Hasnain Isa M, Siew Lang L, Asaari FAH, Aziz HA, Azam Ramli N, Dhas JPA. Low cost removal of disperse dyes from aqueous solution using palm ash. Dye Pigment. 2007;74:446–453. doi: 10.1016/j.dyepig.2006.02.025. [DOI] [Google Scholar]
- Heidary F, Madani S, Gharebaghi R, Asadi-Amoli F. Acyclovir as a potential add-on therapy in COVID-19 treatment regimens. Pharm Sci. 2021;27:S68–S77. doi: 10.34172/PS.2021.38. [DOI] [Google Scholar]
- Hosseini Nasr A, Sadat AH, Tayebee R. Adsorption mechanism of different acyclovir concentrations on 1–2 nm sized magnetite nanoparticles: a molecular dynamics study. J Mol Liq. 2018;254:64–69. doi: 10.1016/j.molliq.2018.01.081. [DOI] [Google Scholar]
- Jain S, Kumar P, Vyas RK, Pandit P, Dalai AK. Occurrence and removal of antiviral drugs in environment: a review. Water Air Soil Pollut. 2013 doi: 10.1007/s11270-012-1410-3. [DOI] [Google Scholar]
- Jain S, Kumar P, Vyas RK, Pandit P, Dalai AK. Adsorption optimization of acyclovir on prepared activated carbon. Can J Chem Eng. 2014;92:1627–1635. doi: 10.1002/cjce.22026. [DOI] [Google Scholar]
- Jain S, Vyas RK, Pandit P, Dalai AK. Adsorption of antiviral drug, acyclovir from aqueous solution on powdered activated charcoal: kinetics, equilibrium, and thermodynamic studies. Desalin Water Treat. 2014;52:4953–4968. doi: 10.1080/19443994.2013.810324. [DOI] [Google Scholar]
- Khadhri N, El Khames SM, Ben Mosbah M, Moussaoui Y. Batch and continuous column adsorption of indigo carmine onto activated carbon derived from date palm petiole. J Environ Chem Eng. 2019;7:102775. doi: 10.1016/j.jece.2018.11.020. [DOI] [Google Scholar]
- Kumari U, Mishra A, Siddiqi H, Meikap BC. Effective defluoridation of industrial wastewater by using acid modified alumina in fixed-bed adsorption column: experimental and breakthrough curves analysis. J Clean Prod. 2021;279:123645. doi: 10.1016/j.jclepro.2020.123645. [DOI] [Google Scholar]
- Li G, Nie X, Gao Y, An T. Can environmental pharmaceuticals be photocatalytically degraded and completely mineralized in water using g-C3N4TiO2 under visible light irradiation? Implications of persistent toxic intermediates. Appl Catal B Environ. 2016;180:726–732. doi: 10.1016/j.apcatb.2015.07.014. [DOI] [Google Scholar]
- Liao P, Zhan Z, Dai J, Wu X, Zhang W, Wang K, Yuan S. Adsorption of tetracycline and chloramphenicol in aqueous solutions by bamboo charcoal: a batch and fixed-bed column study. Chem Eng J. 2013;228:496–505. doi: 10.1016/j.cej.2013.04.118. [DOI] [Google Scholar]
- Liu C, Wang Y, Zhang Y, Xu B, Li R, Song Z, Qi F, Yuan D, Wang Y, Yu B, Chu W, Zhang Y, Meng W. Enhancement of Fe@porous carbon to be an efficient mediator for peroxymonosulfate activation for oxidation of organic contaminants: incorporation NH2-group into structure of its MOF precursor. Chem Eng J. 2018;354:835–848. doi: 10.1016/j.cej.2018.08.060. [DOI] [Google Scholar]
- Liu C, Liu S, Liu Liyuan Tian X, Liu Longyan Xia Y, Liang X, Wang Y, Song Z, Zhang Y, Li R, Liu Y, Qi F, Chu W, Tsang DCW, Xu B, Wang H, lkhlaq A. Novel carbon based Fe-Co oxides derived from Prussian blue analogues activating peroxymonosulfate: refractory drugs degradation without metal leaching. Chem Eng J. 2020;379:122274. doi: 10.1016/j.cej.2019.122274. [DOI] [Google Scholar]
- Maheshwari U, Gupta S. Removal of Cr(VI) from wastewater using activated neem bark in a fixed-bed column: interference of other ions and kinetic modelling studies. Desalin Water Treat. 2016;57:8514–8525. doi: 10.1080/19443994.2015.1030709. [DOI] [Google Scholar]
- Malkoc E, Nuhoglu Y, Dundar M. Adsorption of chromium(VI) on pomace-An olive oil industry waste: Batch and column studies. J Hazard Mater. 2006;138:142–151. doi: 10.1016/j.jhazmat.2006.05.051. [DOI] [PubMed] [Google Scholar]
- Mascolo G, Balest L, Cassano D, Laera G, Lopez A, Pollice A, Salerno C. Biodegradability of pharmaceutical industrial wastewater and formation of recalcitrant organic compounds during aerobic biological treatment. Bioresour Technol. 2010;101:2585–2591. doi: 10.1016/j.biortech.2009.10.057. [DOI] [PubMed] [Google Scholar]
- Momčilović M, Purenović M, Bojić A, Zarubica A, Ranđelović M. Removal of lead(II) ions from aqueous solutions by adsorption onto pine cone activated carbon. Desalination. 2011;276:53–59. doi: 10.1016/j.desal.2011.03.013. [DOI] [Google Scholar]
- Nannou C, Ofrydopoulou A, Evgenidou E, Heath D, Heath E, Lambropoulou D. Antiviral drugs in aquatic environment and wastewater treatment plants: A review on occurrence, fate, removal and ecotoxicity. Sci Total Environ. 2020;699:134322. doi: 10.1016/j.scitotenv.2019.134322. [DOI] [PubMed] [Google Scholar]
- Patel H. Fixed-bed column adsorption study: a comprehensive review. Appl Water Sci. 2019;9:1–17. doi: 10.1007/s13201-019-0927-7. [DOI] [Google Scholar]
- Peng X, Wang C, Zhang K, Wang Z, Huang Q, Yu Y, Ou W. Profile and behavior of antiviral drugs in aquatic environments of the Pearl River Delta. China Sci Total Environ. 2014;466–467:755–761. doi: 10.1016/j.scitotenv.2013.07.062. [DOI] [PubMed] [Google Scholar]
- Pholosi A, Naidoo EB, Ofomaja AE. Batch and continuous flow studies of Cr(VI) adsorption from synthetic and real wastewater by magnetic pine cone composite. Chem Eng Res Des. 2020;153:806–818. doi: 10.1016/j.cherd.2019.11.004. [DOI] [Google Scholar]
- Prasse C, Schlüsener MP, Schulz R, Ternes TA. Antiviral drugs in wastewater and surface waters: a new pharmaceutical class of environmental relevance? Environ Sci Technol. 2010;44:1728–1735. doi: 10.1021/es903216p. [DOI] [PubMed] [Google Scholar]
- Prasse C, Wagner M, Schulz R, Ternes TA. Biotransformation of the antiviral drugs acyclovir and penciclovir in activated sludge treatment. Environ Sci Technol. 2011;45:2761–2769. doi: 10.1021/es103732y. [DOI] [PubMed] [Google Scholar]
- Prasse C, Wagner M, Schulz R, Ternes TA. Oxidation of the antiviral drug acyclovir and its biodegradation product carboxy-acyclovir with ozone: kinetics and identification of oxidation products. Environ Sci Technol. 2012;46:2169–2178. doi: 10.1021/es203712z. [DOI] [PubMed] [Google Scholar]
- Reynel-Avila HE, Mendoza-Castillo DI, Bonilla-Petriciolet A, Silvestre-Albero J. Assessment of naproxen adsorption on bone char in aqueous solutions using batch and fixed-bed processes. J Mol Liq. 2015;209:187–195. doi: 10.1016/j.molliq.2015.05.013. [DOI] [Google Scholar]
- Russo D, Siciliano A, Guida M, Galdiero E, Amoresano A, Andreozzi R, Reis NM, Li Puma G, Marotta R. Photodegradation and ecotoxicology of acyclovir in water under UV254 and UV254/H2O2 processes. Water Res. 2017;122:591–602. doi: 10.1016/j.watres.2017.06.020. [DOI] [PubMed] [Google Scholar]
- Saifi Z, Rizwanullah M, Mir SR, Amin S. Bilosomes nanocarriers for improved oral bioavailability of acyclovir: a complete characterization through in vitro, ex-vivo and in vivo assessment. J Drug Deliv Sci Technol. 2020;57:101634. doi: 10.1016/j.jddst.2020.101634. [DOI] [Google Scholar]
- Shah I, Adnan R, Ngah WSW, Mohamed N. Iron impregnated activated carbon as an efficient adsorbent for the removal of methylene blue: regeneration and kinetics studies. PLoS ONE. 2015;10:1–23. doi: 10.1371/journal.pone.0122603. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shetti NP, Malode SJ, Nayak DS, Naik RR, Kuchinad GT, Reddy KR, Shukla SS, Aminabhavi TM. Hetero nanostructured iron oxide and bentonite clay composite assembly for the determination of an antiviral drug acyclovir. Microchem J. 2020;155:104727. doi: 10.1016/j.microc.2020.104727. [DOI] [Google Scholar]
- Thiebault T, Guégan R, Boussafir M. Adsorption mechanisms of emerging micro-pollutants with a clay mineral: Case of tramadol and doxepine pharmaceutical products. J Colloid Interface Sci. 2015;453:1–8. doi: 10.1016/j.jcis.2015.04.029. [DOI] [PubMed] [Google Scholar]
- Thommes M. Physical adsorption characterization of nanoporous materials. Chem-Ing-Tech. 2010;82:1059–1073. doi: 10.1002/cite.201000064. [DOI] [Google Scholar]
- Tognarelli EI, Palomino TF, Corrales N, Bueno SM, Kalergis AM, González PA. Herpes simplex virus evasion of early host antiviral responses. Front Cell Infect Microbiol. 2019 doi: 10.3389/fcimb.2019.00127. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wu M, Lv H, Wang T, Ao Z, Sun H, Wang C, An T, Wang S. Ag2MoO4 nanoparticles encapsulated in g-C3N4 for sunlight photodegradation of pollutants. Catal Today. 2018;315:205–212. doi: 10.1016/j.cattod.2018.01.019. [DOI] [Google Scholar]
- Yan G, Viraraghavan T, Chen M. A new model for heavy metal removal in a biosorption column. Adsorpt Sci Technol. 2001;19:25–43. doi: 10.1260/0263617011493953. [DOI] [PubMed] [Google Scholar]
- Yoon YH, Nelson JH. Application of gas adsorption kinetics I: a theoretical model for respirator cartridge service life. Am Ind Hyg Assoc J. 1984;45:509–516. doi: 10.1080/15298668491400197. [DOI] [PubMed] [Google Scholar]
- Zhang Y, Zhu H, Szewzyk U, Lübbecke S, Uwe Geissen S. Removal of emerging organic contaminants with a pilot-scale biofilter packed with natural manganese oxides. Chem Eng J. 2017;317:454–460. doi: 10.1016/j.cej.2017.02.095. [DOI] [Google Scholar]
- Zhou C, Chen J, Xie Q, Wei X, Zhang Y, Fu Z. Photolysis of three antiviral drugs acyclovir, zidovudine and lamivudine in surface freshwater and seawater. Chemosphere. 2015;138:792–797. doi: 10.1016/j.chemosphere.2015.08.033. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.