Abstract
Visual detection of nucleic acids is important to diagnose the serious acute infectious diseases such as coronavirus disease 2019 (COVID-19). During this pandemic, reliable visual detection kits have been in high demand for screening and prevention of the virus. While developing these visual detection kits, a real-time monitoring platform is usually applied to study the amplification and detection processes of nucleic acids and optimize the detecting conditions. Herein, we developed a real-time monitoring platform of colorimetric loop-mediated isothermal amplification (LAMP) to investigate the amplification and detection processes of nucleic acids. Using this platform, we could obtain the real-time amplification curves, and optimize the reaction temperature, color change, and detection time. Based on the optimized conditions, a visual detection kit for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was successfully developed with a sensitivity of 102 copies µL−1 in 12 min. This real-time monitoring platform has advantages of simple construction, steady performance, high sensitivity, and outstanding anti-pollution capability, and could replace the traditional colorimetric methods by photographing and reading values. This platform would accelerate the development of visual detection kits for colorimetric LAMP, help to explore the amplification and transcription of nucleic acids, and provide support for the prevention of emerging biological threats.
Keywords: Colorimetric LAMP assay, Visual rapid detection, Monitoring platform, SARS-CoV-2 virus, Nucleic acid detection
Graphical abstract
A real-time monitoring platform was developed for colorimetric LAMP, and the amplification curves for visual detection kits could be obtained to replace the traditional method of photographing.
1. Introduction
Rapid visual detection of nucleic acids is critical for the prevention and control of infectious diseases. A recent representative example is that, during the coronavirus disease 2019 (COVID-19) pandemic, visual detection is required for rapid screening at home, in hospitals, customs, and other venues where fluorescence detection has traditionally been required [1], [2], [3], [4]. In this context, visual detection kits are widely studied and developed in clinical and scientific research, and they are expected to be home-based, self-operated, fail-safe, and error-free [5], [6], [7]. To optimize the performance of these kits, a platform for real-time monitoring visual detection kits will accurately analyze the process of visual detecting and regulate the detection time exactly, provide theoretical support, and have the potential to develop visual detection techniques for nucleic acids.
Existing platforms for monitoring the amplification process of nucleic acids include those based on fluorescent probes [8], electrochemical probes [9], turbidity changes [10], and colorimetric changes [11], [12], [13], [14] (Fig. S1). Among them, real-time quantitative polymerase chain reaction (RT–qPCR) is the most extensively used platform [15,16], which has good sensitivity and specificity (Table S1). However, it requires high-precision instruments and cost, which limits its application scenarios. Moreover, the monitoring platforms based on electrochemical probes detect the changes in molecular conformation [17] and the content of electroactive molecules [12] caused by DNA hybridization. It has high sensitivity but shows poor anti-pollution ability and requires accurate operation [18,19]. The monitoring platform based on turbidity change is used to measure the white precipitation of magnesium pyrophosphate generated during DNA replication, which is produced by the combination of magnesium ions and pyrophosphate ions [10,20]. This method requires turbidimeters and has low sensitivity and false negatives. In addition, another platform is based on colorimetric probes, which mainly includes pH-sensitive molecules [21], [22], [23], [24], gold nanoparticles (Au NPs) [25], and other discoloration molecules. These probes produce visual signals, and can be used at home and other point-of-care scenes [26], [27], [28]. Among those monitoring platform, colorimetric monitoring platform has obvious visual signals and extensive application scenarios [29], [30], [31], [32], [33], [34], [35]. In the existing research, the colorimetric monitoring method is to take photos for reading the chromaticity value [2,22], but there is a lack of real-time monitoring platform to accurately monitor color changes and determine reaction time. To better develop the visual detection kits, a simpler real-time monitoring platform that can directly study the amplification and detection process of nucleic acids is needed.
Herein, we developed a real-time monitoring platform of colorimetric loop-mediated isothermal amplification (LAMP) to investigate the amplification and detection processes of nucleic acids, and to facilitate the development of visual detection kits. This platform could provide amplification curves of colorimetric LAMP (Scheme 1 ), and the criteria of the amplification curve were determined (the absorbance intensity changed from 100% to 50% as the color of the solution changed from pink to orange). This platform also helped to optimize the reaction temperature, color change, and detection time of visual detection kits. Upon the optimized conditions, a visual detection kit for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was successfully developed with a sensitivity of 102 copies µL−1, and the virus RNA were detected in 12 min. This real-time monitoring platform has advantages of simple construction, steady performance, high sensitivity and outstanding anti-pollution capability. It could replace the traditional colorimetric method of photographing and reading values. We believe that it not only contributes to the development of visual detection kits, but also helps to explore the amplification and transcription of nucleic acids, and will provide strong support for the prevention of various diseases.
Scheme 1.
A real-time monitoring platform of colorimetric loop-mediated isothermal amplification (LAMP) for visual detection. (A) The colorimetric LAMP is monitored by the platform, which obtains the amplification curve. (B) The discoloration mechanism of the detection. The color of original solution is pink (i), with the increase of hydrogen ions (H+) which produced by DNA amplification (i.e., the decrease in pH), the molecular structure of phenol red is changed (ii), and the color of the solution turns to yellow (iii).
2. Experimental
2.1. Reagents and chemicals
Primers targeting the N, E, and ORF3 gene were designed based on the SARS-CoV-2 genomic sequence (NC_045512) using Primer Explorer V5 (Eiken Chemical, Tokyo, Japan). Three sets of primers are listed in Table S2. Primers, plasmids, and TE buffer (1×) were purchased from Sangon Biotech (Shanghai, China). 2019-nCoV RNA reference material (high concentration) was provided by the National Institute of Metrology of China (GBW(E)091089, Beijing, China). WarmStart® Colorimetric LAMP 2X Master Mix (DNA & RNA), Bst 2.0 WarmStart DNA Polymerase, Tris–HCl, (NH4)2SO4, KCl, MgSO4, dNTP was from New England Biolabs (Ipswitch, MA, USA). Paraffin liquid was from Macklin (Shanghai, China). Hydrochloric acid (HCl) was obtained from HuaChengDa Chemical Industry (Zhuhai, Guangdong, China).
2.2. Construction of the platform
The real-time monitoring platform was constructed with a visible spectrophotometer, a 3D printed hollow sample cell made of resin with an inlet and an outlet, and a temperature-regulating system (Fig. 1 A).
Fig. 1.
Construction and performance of the real-time monitoring platform for colorimetric LAMP. (A) Photo of the platform setup. (B) The spectrum of the detection kit solution measured by the platform; the inset image is the LAMP reagent in a cuvette. (C) The temperature stability of the platform for 2 h; the inset is the setup for temperature monitoring. (D) The volume stability of the detection kit solution at 65 ℃; the inset of the LAMP reagent in a cuvette. (E) The time-dependent spectra of the detection kit solution at 65 °C. (F) The stability of absorbance intensity at 560 nm in (E).
2.3. Performance tests for the platform
The sample was coated with 50 µL paraffin liquid for liquid sealing. A thermocouple temperature meter (Smart Sensor, Dongguan, Guangdong, China) was used to monitor the temperature of the sample solution. To assess the stability of the light source, it was scanned at 560 nm for 2 h. To determine the sealing performance, the sealed cuvette was heated at 65 ℃ for 2 h. To investigate the ability of resisting aerosol pollution, the no-template control (NTC) and positives were detected alternately.
2.4. LAMP detection by the platform
The sealed cuvette containing the LAMP reaction mixture was placed in the sample cell. Then, the spectra were scanned. There were two patterns to monitor the color. Wavelength scanning was utilized to record the full spectra. Time scanning was employed to record the changes of the absorbance intensity at 560 nm and obtain the amplification curves.
2.5. RT-LAMP visual detection
The detection kits could be used for visual detection by naked eyes. The pink color of the kits was regarded as negative, whereas the yellow color was regarded as positive.
2.6. LAMP protocol
A 25 µL LAMP mixture contained 12.5 µL Bst 2.0 WarmStart DNA Polymerase, 20 mM Tris–HCl, 10 mM (NH4)2SO4, 50 mM KCl, 8 mM MgSO4, 2.8 mM dNTP, 1.6 µM FIP/BIP primers, 0.4 µM LooF/B primers, 0.2 µM F3/B3 primers, 2.5 µL diluted saliva, 2 µL template, and double distilled H2O. The mixed reaction solution was prepared in a neutral solution. And the pH of diluted saliva was between 6.6 and 7.1.
3. Results and discussion
3.1. Construction and evaluation of the real-time monitoring platform
The real-time monitoring platform for colorimetric LAMP was built with adjustable temperature (Fig. 1A). This platform could monitor and analyze the spectrum of colorimetric LAMP reagents (Fig. 1B). To use this platform for monitoring the amplification, its fundamental performance should be steady, such as temperature, light source, tightness, and other properties. To test the stability of the temperature, a thermocouple was connected to the sample solution. The temperature of the solution in the thermostat was maintained at approximately 65 ℃ for 2 h (Fig. 1C), with a varied range of less than 0.5 ℃, demonstrating that the platform could maintain a constant temperature. And the platform needed 9 min to preheat (Fig. S2). Furthermore, the sample solution would not volatilize in the platform. It was sealed with paraffin oil. During the continuous heating process of amplification, the volume and weight of the sample solution remained consistent within 2 h (Fig. 1D), indicating that the platform would not have errors due to volatilization. And the positives and NTCs were alternately tested. The NTCs were unaffected by the positives before and after the measurement in Fig. S3a. The absorbance intensity of positives decreased, while the intensities of NTCs remained close to 100%. There were no false positives due to aerosol pollution (Fig. S3b). The stability of the detecting light source of the platform also has a direct influence on the monitoring results. The sample solution was monitored in the platform for 0, 15, 30, 60, and 120 min, and the spectra were kept stable (Fig. 1E). The absorbance intensity remained nearly constant at 560 nm for 120 min, with just a shift of 0.01 intensity (Fig. 1F). As a result, the platform device had a stable temperature and light source, good airtightness, and high antipollution performance, and the detection kit solution could be monitored continuously.
3.2. The detection principle and feasibility on platform
The monitoring platform could serve the optimization of a colorimetric LAMP kit with the phenol red indicator as a sensitive molecule. The phenol red molecule was employed as an acid-base indicator because of its structural features, and its aqueous solution was pink when alkaline and yellow when acidic (Scheme 1). As the concentration of H+ increased during amplification, the phenol red molecular structure was changed, and the color of the solution gradually became yellow (Fig. 2A). Meanwhile, the spectra of the detection solution also changed in Fig. 2B. Before amplification (red curve), there was an obvious absorption peak at 560 nm. The absorbance intensity of this peak decreased significantly after amplification (yellow curve). The whole amplification process of the detection solution was monitored on the real-time monitoring platform. The absorbance intensity decreased quickly and then gradually stabilized at 560 nm in 2 h (Fig. 2C). This implies that in the early stage of amplification, double-stranded DNA (dsDNA) was synthesized, accompanied by a large amount of H+, which swiftly combined with phenol red to reach the critical point of discoloration. Consequently, the amplification curve could be obtained at 560 nm (Fig. 2D), with a quick reduction at the beginning until the completion of amplification. Therefore, the amplification process of nucleic acids was monitored and the amplification curves of colorimetric LAMP kit with the phenol red indicator was obtained. And this platform could also serve for other sensitive indicator, as the intensity of peak changed obviously (Fig. S4).
Fig. 2.
The mechanism and the feasibility of monitoring the colorimetric LAMP on the platform. (A) Phenol red molecules (i) combine with H+ produced by DNA amplification, resulting in changes in molecular structure (ii). (B) Absorption spectra before (i) and after (ii) amplification. (C) The change of the spectra of the detection kit solution in 2 h. (D) The amplification curve of the detection kit solution at 560 nm.
3.3. Amplification and optimization of nucleic acid detection on the platform
When the real-time monitoring platform was applied to colorimetric LAMP kits, the conditions of the amplification and detection should be optimized. The LAMP assay, as an isothermal amplification technique, has a strict temperature requirement for achieving a steady amplification curve. The reaction temperatures were selected from 60 to 70 °C, which are the temperatures typically used in the LAMP assay. The solution was heated for 15 min at 60, 63, 65, 67, and 70 °C (Fig. 3A), and the absorbance intensity changed at 560 nm. At 65 ℃, the intensity decreased the most to 52.7% compared to the original intensity of 100%. At the same time, the intensity decreased to 90% at 60 °C, 80% at 63 °C, 57% at 67 °C, and 63% at 70 °C. The temperature with the most obvious reaction was 65 °C. And the amplification curves were also monitored at these temperatures. The absorbance intensity of the amplification curve decreased fastest at 65 °C (Fig. 3B). At 65 °C, the intensity decreased to 50% using 17 min, using 32 min at 60 °C, 36 min at 63 °C, 23 min at 67 °C, and 31 min at 70 °C (Fig. 3C). Therefore, the amplification would be steady and quick at 65 °C, and this temperature could be selected as the optimal reaction temperature for this visual detection kit.
Fig. 3.
Optimizing the performance of the visual detection kit on the real-time monitoring platform. (A) The absorption spectra of detection kit solution at 60, 63, 65, 67, and 70 ℃ for 15 min; (B) The amplification curves at different temperatures. (C) The amplification time required at different temperatures. (D) The spectra of the detection kit solution varied with pH. (E) Photos of the solution color changed with pH. (F) The normalized absorbance (blue line) and the yellow color value (orange line) of the detection kit solution changed with pH. (G) The amplification curve of the detection kit solution for 120 min. (H) Photos of the detection kit solution amplified for 2 h.
Using the amplification curve monitored on the platform, the detection time could be determined and the detection process could also be judged. A judgment criterion was produced by comparing the absorbance intensity of amplification curve and the color of detection solution color. According to the principle in Section 3.2, the concentration of H+ has a direct influence on the solution color and the absorbance spectra. Therefore, HCl was gradually added to the detection solution, to determine the judgment criterion of the amplification curve corresponding to the pH change. In Fig. 3D, line a (brownish red solid line) was the beginning without HCl. The absorbance intensity at 560 nm of line a was set as 100%, and the solution color was pink in the photo a of Fig. 3E. The first change point is related to line n (red solid line), in which the absorbance intensity decreased to 52.7%, and the color of solution changed to orange in the photo n. The next change point is related to line o (red dotted line), where the absorbance intensity changed to 31.6% and the color of solution changed to yellow in the photo o. The color of solution changed from pink to orange and finally to yellow in Fig. 3E, which corresponded to the spectra in Fig. 3D. Finally, the relationship between the absorbance intensity and the yellow value of the solution color was compared (Fig. 3F). The intensity of the 560 nm peak (blue curve) and yellow value of the solution color (orange curve) changed most noticeably at point n to point o. Therefore, the judgment criteria of the amplification curve could be identified at the first change point. The absorbance intensity dropped from 100% to approximately 50% at 560 nm, while the solution color became orange, indicating that the nucleic acids had been amplified.
According to the judgment criteria of the amplification curve, the absorbance intensity decreasing to 50% was set as the change point for the reaction (Fig. 3G). The amplification took 12 min. Simultaneously, the color of the solution was monitored under identical reaction conditions. It was obvious that the color of the positive changed from pink to orange at approximately 15 min and then to yellow at approximately 30 min, while the NTC remained pink (Fig. 3H). As a result, the detection time of this visual detection kit was accurate to 12 min on this real-time monitoring platform.
3.4. The sensitivity of nucleic acid detection measured by the platform
The visual detection kit optimized by the real-time monitoring platform was used to detect the sensitivity of SARS-CoV-2 gene templates. When the concentrations of templates were 108, 106, 104, and 102 copies µL−1, the absorbance intensity of amplification curves decreased to below 50% at 12 min (Fig. 4A). The absorbance intensity was not reduced to 50% on the amplification curves of detection solution containing templates of 101 and 100 copies µL−1 and NTC. Similarly, under identical reaction conditions, the color of detection solution was observed by naked eyes in Fig. 4B. The color of detection solution was changed from pink to orange with 108 and 106 copies µL−1 at 10–15 min. The reaction with templates of 104 and 102 copies µL−1 took 25 min to change the color of solution. And the solution with 101 and 100 copies µL−1 templates changed from pink to orange at 60 min, while there was no significant change in NTC. Therefore, judging the reaction process from the amplification curve was more sensitive and faster than analyzing the color change of visual observation. The detection sensitivity was maintained at 102 copies µL−1 in 12 min on the amplification curve through the platform. The other DNA sequences presenting in real samples, like DNAs of Escherichia coli, Staphylococcus aureus, Helicobacter pylori, and HaCaT cells, did not interfere with the determination process (Fig. S6).
Fig. 4.
The sensitivity of the nucleic acid detection measured with the real-time monitoring platform using the optimized detection solution. The amplification curves (A) and photos (B) of the solution at 65 °C, with different concentrations of nucleic acids ranging from 108 to 100 copies µL−1.
3.5. Visual rapid detection of SARS-CoV-2 RNA with a platform-optimized kit
This real-time monitoring platform provides a dependable research strategy for visual detection kits or terminals through the amplification curve. As shown in Fig. 5A, the color of the platform-optimized detection kit was originally pink. After amplification in a thermos at 65 ℃ for 12 min, the color became yellow. The platform-optimized kits could be employed efficiently for rapid and visual detection, such as detecting SARS-CoV-2 RNA. Fig. S5a shows the time-dependent spectra for RNA detection, and the absorbance intensity of the amplification curve was reduced to 50% (Fig. S5b). Therefore, the platform-optimized kit could be used to detect the E and N genes of SARS-CoV-2 RNA to realize rapid visual detection. The amplification in the thermos was successful, and positive discoloration was observed at 12 min (Fig. 5B). The platform was also sensitive towards different strains of SARS-CoV-2 like Omicron and different viral species like Middle East respiratory syndrome-related coronavirus (Fig. S7).
Fig. 5.
Development of a rapid visual detection kit for SARS-CoV-2 based on the amplification curve from the real-time monitoring platform. (A) The sample with the optimized detection kit was heated at 65 ℃ in thermos, and could be observed by naked eyes. (B) The photos of detecting the N and E genes of SARS-CoV-2 RNA samples with the optimized detection kit solution.
The real-time LAMP monitoring platform has good performance for nucleic acid detection. This platform could complete the optimization of the detection kit and obtain the optimal reaction conditions. At the same time, we obtained the nucleic acid amplification curves of the visual detection kit for SARS-CoV-2, and improved the reaction temperature, color, and time. The platform-optimized kit could be applied to simple visual detection methods, such as rapid and easy amplification in a thermos. As a result, our platform could provide the groundwork and novel research methods for the development of visual kits.
4. Conclusions
Based on the real-time monitoring platform of colorimetric LAMP, we investigated the amplification curve of a visual detection kit and finally refined a visual detection kit which detected the SARS-CoV-2 virus in 12 min. It was utilized to monitor and study the detection process of colorimetric LAMP in real time. Meanwhile, this platform was used to optimize the reaction temperature, color change, and detection time of visual detection kits. For the visual detection kit, the criterion of intensity in the amplification curves was defined (initial intensity changed from 100% to 50%, and the color of the solution changed from pink to orange). It may also serve as a real-time monitoring platform for the development of other visible detection kits and a dependable research strategy for more terminal detection methods, as well as a convenient method for nucleic acid detection and large-scale disease screening and prevention.
CRediT authorship contribution statement
Quanying Fu: Investigation, Methodology, Reaction parameter optimization, Data processing, Statistical analysis, Writing. Xueyuan Pang: Reaction parameter optimization, detection device preparation, data processing. Xiulei Li: Detection device preparation, Discussion. Qiming Zhou: Providing sampling tubes, Discussion. Jiasi Wang: Methodology, Primer design. Jianhua Zhou: Conceptualization, methodology, writing, funding acquisition.
Declaration of Competing Interest
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Acknowledgement
This work was supported by the National Key R&D Program of China (2021YFF0703300), the National Natural Science Foundation of China (22174167), the Fundamental Research Funds for the Central Universities (20lgzd28 and 20lgpy124), the Shenzhen Research Funding Program (JCYJ20190807160401657 and JCYJ20180307155036127), and the Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument (2020B1212060077).
Footnotes
Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.cjac.2023.100274.
Appendix. Supplementary materials
References
- 1.Zhang T., Deng R., Wang Y., Wu C., Zhang K., Wang C. A paper-based assay for the colorimetric detection of SARS-CoV-2 variants at single-nucleotide resolution. Nat Biomed Eng. 2022;6:957–967. doi: 10.1038/s41551-022-00907-0. [DOI] [PubMed] [Google Scholar]
- 2.Bokelmann L., Nickel O., Maricic T., Pääbo S., Meyer M., Borte S., et al. Point-of-care bulk testing for SARS-CoV-2 by combining hybridization capture with improved colorimetric LAMP. Nat Commun. 2021;12:1467. doi: 10.1038/s41467-021-21627-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Baek Y., Um J., Antigua K., Park J., Kim Y., Oh S., et al. Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2. Emerg Microbes Infect. 2020;9:998–1007. doi: 10.1080/22221751.2020.1756698. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Yin K., Pandian V., Kadimisetty K., Zhang X., Ruiz C., Cooper Y., et al. Real-time colorimetric quantitative molecular detection of infectious diseases on smartphone-based diagnostic platform. Sci Rep. 2020;10:9009. doi: 10.1038/s41598-020-65899-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Gun-Soo P., Keunbon K., Seung-Hwa B., Seong-Jun K., Il K., Bum-Tae K., et al. Development of reverse transcription loop-mediated isothermal amplification assays targeting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) J Mol Diagn. 2020;22:729–735. doi: 10.1016/j.jmoldx.2020.03.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Hasick N., Ramadas R., Todd A. Subzymes: regulating DNAzymes for point of care nucleic acid sensing. Sens Actuators B Chem. 2019;297 [Google Scholar]
- 7.D’Agata R., Spoto G. Advanced methods for microRNA biosensing: a problem-solving perspective. Anal Bioanal Chem. 2019;411:4425–4444. doi: 10.1007/s00216-019-01621-8. [DOI] [PubMed] [Google Scholar]
- 8.Maddali H., Miles C., Kohn J., O’Carroll D. Optical biosensors for virus detection: prospects for SARS-CoV-2/COVID-19. ChemBioChem. 2020;22:1176–1189. doi: 10.1002/cbic.202000744. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Chaibun T., Puenpa J., Ngamdee T., Boonapatcharoen N., Athamanolap P., O’Mullane A., et al. Rapid electrochemical detection of coronavirus SARS-CoV-2. Nat Commun. 2021;12:802. doi: 10.1038/s41467-021-21121-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Mori Y., Kitao M., Tomita N., Notomi T. Real-time turbidimetry of LAMP reaction for quantifying template DNA. J Biochem Biophys Methods. 2003;59:145–157. doi: 10.1016/j.jbbm.2003.12.005. [DOI] [PubMed] [Google Scholar]
- 11.Zhou R., Li Y., Dong T., Tang Y., Li F. A sequence-specific plasmonic loop-mediated isothermal amplification assay with orthogonal color readouts enabled by CRISPR Cas12a. Chem Commun. 2020;56:3536–3538. doi: 10.1039/d0cc00397b. [DOI] [PubMed] [Google Scholar]
- 12.Pashchenko O., Shelby T., Banerjee T., Santra S. A comparison of optical, electrochemical, magnetic, and colorimetric point-of-care biosensors for infectious disease diagnosis. ACS Infect Dis. 2018;4:1162–1178. doi: 10.1021/acsinfecdis.8b00023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Zhang X., Lowe S., Gooding J. Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP) Biosens Bioelectron. 2014;61:491–499. doi: 10.1016/j.bios.2014.05.039. [DOI] [PubMed] [Google Scholar]
- 14.Zhang M., Ye J., He J., Zhang F., Ping J., Qian C., et al. Visual detection for nucleic acid-based techniques as potential on-site detection methods. A review. Anal Chim Acta. 2020;1099:1–15. doi: 10.1016/j.aca.2019.11.056. [DOI] [PubMed] [Google Scholar]
- 15.Li C., Wang Z., Wang L., Zhang C. Biosensors for epigenetic biomarkers detection: a review. Biosens Bioelectron. 2019;144 doi: 10.1016/j.bios.2019.111695. [DOI] [PubMed] [Google Scholar]
- 16.Cheng Y., Dong L., Zhang J., Zhao Y., Li Z. Recent advances in microRNA detection. Analyst. 2018;143:1758–1774. doi: 10.1039/C7AN02001E. [DOI] [PubMed] [Google Scholar]
- 17.Hsieh K., Ferguson B., Eisenstein M., Plaxco K., Soh H. Integrated electrochemical microsystems for genetic detection of pathogens at the point of care. Acc Chem Res. 2015;48:911–920. doi: 10.1021/ar500456w. [DOI] [PubMed] [Google Scholar]
- 18.Xiao H., Lin H., Cao Y., Hsing I. Rapid and highly specific detection of communicable pathogens using one-pot loop probe-mediated isothermal amplification (oLAMP) Sens Actuators B Chem. 2022;357 [Google Scholar]
- 19.Hsieh K., Patterson A., Ferguson B., Plaxco K., Soh H. Rapid, sensitive, and quantitative detection of pathogenic DNA at the point of care through microfluidic electrochemical quantitative loop-mediated isothermal amplification. Angew Chem Int Ed. 2012;51(20):4896–4900. doi: 10.1002/anie.201109115. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Sappat A., Jaroenram W., Puthawibool T., Lomas T., Tuantranont A., Kiatpathomchai W. Detection of shrimp Taura syndrome virus by loop-mediated isothermal amplification using a designed portable multi-channel turbidimeter. J Virol Methods. 2011;175:141–148. doi: 10.1016/j.jviromet.2011.05.013. [DOI] [PubMed] [Google Scholar]
- 21.Tanner N., Zhang Y., Jr T. Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes. BioTechniques. 2015;58:59–68. doi: 10.2144/000114253. [DOI] [PubMed] [Google Scholar]
- 22.Lalli M., Langmade J., Chen X., Fronick C., Sawyer C., Burcea L., et al. Rapid and extraction-free detection of SARS-CoV-2 from saliva by colorimetric reverse-transcription loop-mediated isothermal amplification. Clin Chem. 2021;67:415–424. doi: 10.1093/clinchem/hvaa267. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Priye A., Ball C., Meagher R. Colorimetric-luminance readout for quantitative analysis of fluorescence signals with a smartphone CMOS sensor. Anal Chem. 2018;90:12385–12389. doi: 10.1021/acs.analchem.8b03521. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Xie S., Yuan L., Song Y., Zhuo Y., Li T., Chai Y., et al. Using the ubiquitous pH meter combined with a loop mediated isothermal amplification method for facile and sensitive detection of Nosema bombycis genomic DNA PTP1. Chem Commun. 2014;50:15932–15935. doi: 10.1039/c4cc06449f. [DOI] [PubMed] [Google Scholar]
- 25.Liu Y., Li Y., Li M., Ma C., Sun H., Huo Q., et al. A novel isothermal detection method for the universal element of genetically modified soybean. Biologia. 2020;75:2395–2402. [Google Scholar]
- 26.Kim H., Lee J., Lee B., Choi J., Kim K., Song N., et al. Development of MRSA and MRAB detection kit employing loop-mediated isothermal amplification and colorimetric indicator dye. Dyes Pigm. 2019;170 [Google Scholar]
- 27.Zhao T., Yan W., Dong F., Hu X., Xu Y., Wang Z., et al. A smartphone-based platform for ratiometric visualization of SARS-CoV-2 via an oligonucleotide probe. Microchim Acta. 2022;189:268. doi: 10.1007/s00604-022-05364-9. [DOI] [PubMed] [Google Scholar]
- 28.Yan L., Zhou J., Zheng Y., Gamson A., Roembke B., Nakayama S., et al. Isothermal amplified detection of DNA and RNA. Mol BioSyst. 2014;10:970–1003. doi: 10.1039/c3mb70304e. [DOI] [PubMed] [Google Scholar]
- 29.Asiello P., Baeumner A. Miniaturized isothermal nucleic acid amplification, a review. Lab Chip. 2011;11:1420–1430. doi: 10.1039/c0lc00666a. [DOI] [PubMed] [Google Scholar]
- 30.Yan C., Cui J., Huang L., Du B., Chen L., Xue G., et al. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay. Clin Microbiol Infect. 2020;26:773–779. doi: 10.1016/j.cmi.2020.04.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Nawattanapaiboon K., Pasomsub E., Prombun P., Wongbunmak A., Jenjitwanich A., Mahasupachai P., et al. Colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a visual diagnostic platform for the detection of the emerging coronavirus SARS-CoV-2. Analyst. 2021;146:471–477. doi: 10.1039/d0an01775b. [DOI] [PubMed] [Google Scholar]
- 32.Gurrala R., Lang Z., Shepherd L., Davidson D., Harrison E., McClure M., et al. Novel pH sensing semiconductor for point-of-care detection of HIV-1 viremia. Sci Rep. 2016;6:36000. doi: 10.1038/srep36000. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.González-González E., Lara-Mayorga I., Rodríguez-Sánchez I., Zhang Y., Martínez-Chapa S., Trujillo-de Santiag G., et al. Colorimetric loop-mediated isothermal amplification (LAMP) for cost-effective and quantitative detection of SARS-CoV-2: the change in color in LAMP-based assays quantitatively correlates with viral copy number. Anal Methods. 2021;13:169–178. doi: 10.1039/d0ay01658f. [DOI] [PubMed] [Google Scholar]
- 34.Lu R., Wu X., Wan Z., Li Y., Jin X., Zhang C. A novel reverse transcription loop-mediated isothermal amplification method for rapid detection of SARS-CoV-2. Int J Mol Sci. 2020;21:2826. doi: 10.3390/ijms21082826. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Thi V., Herbst K., Boerner K., Meurer M., Kremer L., Kirrmaier D., et al. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples. Sci Transl Med. 2020;12:eabc7075. doi: 10.1126/scitranslmed.abc7075. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.







