To the Editor,
Leadless pacemakers have been clinically available in the selected patients. Yu and colleagues compared the impact on patients' quality of life between leadless pacemakers and conventional transvenous pacemakers. 1 They found that leadless pacemakers were associated with a greater quality of life with fewer activity limitations due to surgical discomfort and less emotional distress. Several concerns have been raised.
The indication of each pacemaker is unclear. A leadless pacemaker might be sufficient in patients with bradycardia‐tachycardia syndrome (sick sinus syndrome type III), given that they are seldom dependent on pacemakers. On the contrary, symptomatic sinus bradycardia (sick sinus syndrome type I) always requires atrial pacing and conventional intravenous pacemakers should be essential. Thus, the device selection might be affected also by the etiologies.
The types of surgery‐related complications are unclear. In their study, the incidence of surgery‐related complications following conventional pacemaker implantation is 21%, 1 which is relatively higher than the other previous studies. For example, Tjong and colleagues reported 4.7% of device‐related complications following conventional intra‐venous pacemaker implantation and 0.9% following leadless pacemaker implantation. 2
For the device selection, we should consider also the anatomical feature of each patient. For example, a larger right atrial diameter is associated with longer procedural time during leadless pacemaker implantation. 3 The leadless pacemaker implantation failed in a patient with an extremely large right atrium. 4 Thus, we believe that we had better consider several factors other than patients' quality of life for the optimal device selection.
DATA AVAILABILITY STATEMENT
Not available.
REFERENCES
- 1. Yu M, Li YP, Shi DM, Zhou YJ. Comparation of quality of life in Chinese patients undergoing leadless versus conventional pacemaker implantation. Clin Cardiol. 2022;46:49‐56. 10.1002/clc.23939 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Tjong FVY, Knops RE, Udo EO, et al. Leadless pacemaker versus transvenous single‐chamber pacemaker therapy: a propensity score‐matched analysis. Heart Rhythm. 2018;15(9):1387‐1393. [DOI] [PubMed] [Google Scholar]
- 3. Kataoka N, Imamura T, Koi T, Ueno H, Kinugawa K. The large right heart is associated with the prolongation of the procedure time of leadless pacemaker implantation. Medicina. 2021;57(7):685. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Imamura T, Koi T, Kataoka N, Tanaka S, Ueno H, Kinugawa K. Micra trans‐catheter leadless pacemaker implantation in a patient with large right heart. J Cardiol Cases. 2021;24(3):136‐139. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not available.