1. INTRODUCTION
Technology innovation has always been one of the main drivers for the evolution of the radiation oncology field. New commercial devices are emerging at a fascinating speed, that is, Magnetic Resonance Imaging (MRI)‐based linac, Positron Emission Tomography (PET)‐based linac, FLASH ultra‐high dose rate delivery, ring gantry with double stacked multi‐leaf collimators (MLC), etc. Meanwhile, technology that has already been widely adopted and used for many patients seems to have stagnated. 4DCT was first introduced in 2003, exactly 20 years ago, 1 aiming to reconstruct “dynamic volumetric imaging” or “respiration‐correlated CT”. It adds a temporal dimension to the traditional 3DCT and provides visualization of target motion. Subsequent clinical trials for anatomy sites pertaining to moving targets imposed a vastly reduced planning target margin using 4DCT. 2 , 3 The entire field has benefited from the addition of this technology, with informed knowledge of its limitations, that is, motion uncertainties and image artifacts resulted from the irregularity of patients' breathing patterns. From a clinical physicist's point of view, 20 years have gone by, and the developments on 4DCT seem to be mostly on paper, with minimum to none being incubated to mature commercial products. We cannot help but wonder should we call for vendors' attention to devote resources in innovating 4DCT technology since it is long overdue for commercial developments, or should we be made aware that incremental developments have been trialed out, but fundamental limitations of 4DCT are hard to be overcome? We are now passing these questions to two experienced physicists with expertise in motion management and 4DCT. Dr. Erik Tryggestad argues for the proposition that “4DCT is long overdue for improvement” while Dr. Heng Li argues against it.
Dr. Erik Tryggestad is an Associate Professor and Consultant of Medical Physics in the Department of Radiation Oncology at Mayo Clinic, Rochester (MN), having recently marked 10 years working at Mayo's Proton Beam Therapy Center. Prior to his faculty positions at Mayo, he was an Assistant Professor at Johns Hopkins University in the Department of Radiation Oncology. Dr. Tryggestad earned his PhD in experimental nuclear physics from Michigan State University's National Superconducting Cyclotron Laboratory in 2001 and ultimately transitioned to medical physics as a post‐doctoral research fellow at the end of 2004 at Johns Hopkins University. Dr. Tryggestad works in the clinic covering proton therapy and Gamma Knife radiosurgical procedures. His research and translational interests include motion management, image guidance, and aspects of radiotherapy workflow automation (especially AI‐based autosegmentation). Dr. Tryggestad has contributed to over 75 peer‐reviewed publications in scientific journals.
Dr. Heng Li is an Associate Professor in the Department of Radiation Oncology and Molecular Radiation Sciences at Johns Hopkins University and is a fellow of the American Association of Physicists in Medicine. He serves as the Chief Proton Physicist of the Johns Hopkins Proton Therapy Center, located at the Sibley Memorial Hospital, Washington DC. He completed his PhD in Electrical and Computer Engineering at the University of Virginia, Charlottesville, VA in 2006, and received postdoctoral fellowship and therapeutic medical physics residency training at the University of Texas MD Anderson Cancer Center. His research interests include proton therapy physics, motion management in radiotherapy, global health, and AI application in radiation oncology. He has published over 70 scientific papers in peer‐reviewed academic journals and authored 9 book chapters.
2. OPENING STATEMENT
2.1. For the proposition: Erik Tryggestad, PhD
I entered the field at the tail end of 2004, taken under the wing as a post‐doctoral fellow by one of our most impactful image‐guided radiotherapy (IGRT) innovators, Dr. John W. Wong (FAAPM, Quimby Awardee), just as 4DCT was being translated clinically. Synergistically (no pun intended; thanks partly to JWW and his colleagues), the year before, the first cone‐beam CT (CBCT)‐guided linear accelerators were introduced. 4 , 5 On‐board kV 2D, 2D fluoroscopy, 2D/3D, kV CBCT, and MVCT imaging catapulted us to the modern 4D‐IGRT era.
The first methods for 4DCT were described in 2003 for helical or conventional CT and CBCT (e.g., 1 , 6 ). Consequently, 4DCT‐informed “motion management” based on 4D‐CT simulation became a hot topic. 7 Indeed, for the first time we had a 4D radiotherapy treatment planning (RTP) tool providing a patient‐specific, 3D target‐motion estimation. Thus, the Internal Target Volume (ITV)‐based approach for RTP leveraged this more explicit ITV, significantly reducing either a population‐based 3D margin expansion or an envelope based on multiple conventional/3D CT scans. 8 , 9 Almost overnight, 4DCT revolutionized RTP for gated RT deliveries, 10 , 11 allowing for hypothetical reduction in this patient‐specific ITV corresponding to a portion of respiration. Meanwhile, thanks to the near‐elimination of inter‐fraction setup margins 12 afforded by on‐board 3D IGRT, new 4DCT informed vigor was injected into the concept of “probabilistic” RTP (e.g., 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 ). On paper, it was shown that 4D‐probabilistic plans could reduce prescription treatment volumes such that they could compete with gating and tumor tracking while using the full respiratory duty cycle, yielding an optimal efficiency. 16 , 19 , 22 , 23 Along the way, deformable image registration (DIR) 24 , 25 filled a big gap as the enabling technology for the more generic emergence of “4D RTP,” be that for 4D dose accumulation (retrospective evaluation) or implicit with 4D optimization (which we might now refer to as robust 4D planning). More recently, pencil beam scanning (PBS) for protons and ion beams has pushed the envelope in this respect given heightened concerns over motion interplay compared with conventional x‐rays. 26 Commercial offerings for robust 4D planning now exist and 4D dose accumulation considering PBS delivery timing information is recommended as “vital” for PBS clinical deployment by the AAPM Task Group 290. 27
Here's my frustration: Twenty years since initial adoption of 4DCT on conventional CT scanners and with the hindsight of all the 4DCT‐enabled innovations that followed, if we evaluate how 4DCT simulation is predominantly deployed today, we find that 4DCT's original limitations clearly persist. True, we've gone from ∽16‐ to ∽128‐slice CT simulators, making 4DCT acquisition slightly faster. But, 4DCT is dose constrained; therefore, it forcibly represents a snapshot in time. Clinical 4DCT is predominantly built upon retrospective sorting (purely from a 1D external surrogate) using slice stacking. Binning is predominantly based purely on either phase or amplitude (with preference towards the former given the probabilistic advantages).
News flash : RT patients do not breathe like programmable robots providing the smooth and predictable respiration that most of our 4D validation phantom and in‐silico studies are based upon. Because our patients do not breathe like robots, and because 4DCT imaging has not significantly evolved, we are often forced to work clinically with a 4DCT simulation image that is artifact‐prone in the context of variable breathing (i.e., containing volume inconsistencies). Granted, our predominant 4DCT deployment using only a 1D external motion surrogate information simplifies downstream IGRT. But, physicists, how do we clinically cope with an artifact‐ridden 4DCT simulation image? How can we anticipate those patients for which we've failed to capture a truly representative snapshot of breathing and accurate motion baseline? At my esteemed institution, we're essentially generating 4DCT with the same surrogate device and method described originally in, 6 despite the fact that many in academia have been working hard on incremental improvements to 4DCT over these 20 years (no offense to my friend and former colleague, Dr. Eric Ford).
One excellent incremental improvement example was published by Olsen et al., wherein the authors proposed a hybrid amplitude‐percentile binning strategy to reduce volume inconsistencies. 28 This simple technique does not require fancy image processing and results in equivalency with the probabilistic (equal‐time weighted, phase) bins we've come to rely upon. I even hijacked this method for my earliest foray into 4D‐MRI 29 and it helped deal with our basic real‐world problem of breathing irregularity. I tell this story because I think it calls attention to commercial 4DCT stagnation and long‐term disconnect that seemingly persists.
For all the good things enabled by improvements to robust 4D planning infrastructure, let's work on mainstream translation of “4DCT 2.0!” Better sorting schemes, potentially involving internal image surrogates, have been shown to reduce volume inconsistencies. 28 , 30 , 31 Despite its well‐understood flaws, DIR can help. 32 , 33 , 34 Artificial intelligence (AI) can help with noise reduction of lower‐dose projections enabling oversampling. 35 , 36 Roughly 15 years of academic investigation has demonstrated that MRI can generate a representative 4D image leveraging longer acquisition times (e.g., 20 , 21 , 37 , 38 ), although, historically, MRI is fraught with prohibitive signal‐to‐noise ratio issues in the thorax. Perhaps 4DCT and 4D‐MRI can join forces to overcome their respective deficiencies?
2.2. Against the proposition: Heng Li, PhD
4DCT is the standard tool for simulation and treatment planning for radiation therapy of mobile tumors. Taking the proposition literally, “4DCT is long overdue for improvements” implies that no improvements, or not many, have been made for a long time. However, since the early 2000s, when 4DCT was introduced, 39 , 40 there has been a massive body of literature on the topic. I will review some of the literature below that showed (1) the tremendous improvement of 4DCT over the past two decades and (2) the fundamental problems of 4DCT that incremental improvements could not address.
2.2.1. Simulation: Image quality and artifacts
4DCT is used to visualize the respiratory motion during simulation. The patient's respiratory motion leads to inconsistencies in data for conventional free breathing 3DCT (fan‐beam CT, FBCT) reconstruction. The 4DCT technique reduces/removes the inconsistency by binning the CT data into different breathing phases. It is important to note that 4DCT techniques assume regular breathing patterns so that the data can be correctly assigned to individual phases. As such, breathing irregularities could cause motion artifacts and inaccuracies in quantifying target motion. 41 Indeed, one study suggested that 4DCT image artifacts correlated with worse local control in SBRT of lung and liver metastases. 42 Tremendous efforts have been made, which has resulted in a better understanding of contributing factors and mitigation strategies to reduce 4DCT motion artifacts 43 , 44 and enhance image qualities. 45 , 46 However, because of the relatively short 4DCT acquisition time, it is difficult to acquire sufficient data for artifact‐free 4DCT reconstruction with the presence of irregular breathing. Alternative techniques, including 5D CT 32 and 4D MRI, 41 which both allow much longer acquisition time, mitigation strategies to reduce the degree of breathing irregularities, 41 or independent review of 4DCT scans, 47 are possible solutions to the problem—but either are outside the scope of improving 4DCT or have not reached maturity for commercialization.
2.2.2. Treatment planning: Target delineation
4DCT is used for target delineation in the radiotherapy of mobile tumors. The process often involves delineating target volume on individual phases, the maximum intensity projection (MIP), or the average intensity projection data sets. It has a clear advantage over FBCT‐based target delineation, which assumes the target is static. Still, the accuracy of the 4DCT‐based delineation is also the subject of acquisition techniques and could be impacted by image artifacts. In 2011 and 2018, two multi‐institute 4DCT phantom studies revealed similar results where 4DCT‐based delineation could lead to significant volume deviations, whereas the amplitude deviation was generally small but could be systematic. 48 , 49 Certainly, more accurate target delineation would lead to a reduced need for margins and improved treatment plan quality. In recognizing the need to quantify target delineation uncertainties, a more recent study showed that a comprehensive QA of 4DCT could quantify the system's performance. The authors proposed acceptable volume and amplitude deviation criteria after fine‐tuning acquisition parameters and evaluating results from various phantom studies, with regular and irregular breathing patterns. 50
2.2.3. Treatment delivery
4DCT‐based treatment planning achieved superior results compared to conventional FBCT‐based plans, even when the FBCT‐based plan employed generous margins. 51 Whereas, framing 4DCT as an integrated part of radiation treatment, one could argue that 4DCT merely captures a snapshot of the patient's respiratory motion at simulation. After considering the irregular patient‐specific respiratory motion, the delivered dose to the patient could deviate from the 4DCT‐based dose calculation. 52 Therefore, improving dose calculation accuracy by incorporating patient breathing patterns during treatment is undoubtedly desirable. However, understanding or capturing a full picture of a patient's breathing pattern, instead of a snapshot, might not be realistically achievable, especially for patients with difficulty breathing or other health issues. It is likely that, any incremental improvement of 4DCT, might theoretically mitigate the uncertainty issue or 4DCT artifacts, but clinically might not make any significant differences. Instead, investigation on real‐time volumetric imaging at the treatment position, for example, MR‐linac, or active motion management techniques such as breath hold or gating, are more likely to improve the accuracy of delivered dose calculation.
In summary, 4DCT has undergone continuous and substantial improvement over the past two decades since its invention, yet the same fundamental issues persist. In other words, it is unrealistic to expect any incremental improvement with clinical significance in 4DCT as long as its limitation is tied to unsolvable issues, that is, inconsistency and irregularity in the patient's breathing pattern.
3. REBUTTAL
3.1. For the proposition: Erik Tryggestad, PhD
Well played, Dr. Li! Paraphrasing from my esteemed friend's summary arguments: 4DCT has a fatal flaw which is revealed in the context of irregular breathing; incremental improvements will not overcome this. I agree with Dr. Li that we should have grounded and realistic expectations. However, we must ask: has mainstream (i.e., clinically adopted) 4DCT reached its technological ceiling? Most emphatically, “no it has not!”
Irregular breathing is far from occasional in the radiation oncology setting. 20 , 21 , 53 , 54 , 55 , 56 , 57 Therefore, 4DCT reconstruction artifacts stemming from this problem are both significant and extremely common. 33 , 58 , 59 However, based on my own 18 years of clinical experience (most recently, 10 years spent in the proton therapy realm where we take great care to monitor 4DCT stability) most of the time we do tend to capture our patients' correct expiratory baseline (even for “irregular breathers”). As such, an achievable goal for 4DCT is to improve upon our definition or concept of “representative motion from the observed baseline.”
I believe that our innovative community has already identified the key elements that can and should comprise the mainstream concept of “4DCT 2.0.” We have an excellent benchmark, which both Dr. Li and I cited above, coming from Dr. Dan Low and colleagues, namely “5DCT.” 31 , 32 , 33 5DCT involves acquisition of N (e.g., 25) conventional (low‐dose) fast helical CTs along with the recording of a traditional 1D external surrogate; then 3D DIR (CT1‐CTN) is used, along with analysis of the respiratory surrogate, to reconstruct an average 3D CT representation for any user‐selected breathing phase or bin. Three elements of 5DCT are important, if not crucial: (1) a significantly oversampled CT acquisition, (2) sampling of given slices of anatomy evenly throughout the full acquisition duration to minimize systematic bias, and (3) use of a 1D respiratory signal that has an analog or correlate with the device to be used for downstream IGRT. The main gaps (naively, as I conceive of them) are technologies that enable significant dose reduction (commensurate with the needed oversampling boost) and companion decision‐enabling tools that allow the physicist to interact with and evaluate the reconstruction in a transparent fashion. Importantly, evaluation of the respiratory surrogate waveform in advance of, or even during, CT acquisition could (dynamically) inform the choice of oversampling rate. 60 In practice, I believe the only concession we need to be willing to make is with respect to time: “4DCT 2.0” necessarily must take slightly longer to acquire.
3.2. Against the proposition: Heng Li, PhD
I agree with my opponent that the 4DCT's original limitations have persisted since its inception. That is, the inability to handle irregular breathing, and as a snapshot of the patient's respiratory motion, it does not necessarily represent the patient's breathing during treatment. However, we disagree if improvements in 4DCT technology could meaningfully mitigate these limitations.
Indeed, as both my opponent and I agree, numerous incremental improvements in the 4DCT technique have led to better images with fewer artifacts. However, what impact do these improvements have on radiotherapy simulation, treatment planning, and delivery?
Dr. Tryggestad suggested that improved binning in 4DCT could help remedy the irregular breathing problem. Indeed, it was shown that amplitude‐based (including hybrid) binning could reduce image artifacts compared to phase‐based binning. However, that may not necessarily translate into better imaging for radiotherapy. Li et al. compared target delineation results using amplitude‐based and phase‐based binning 4DCT images. They illustrated that while amplitude‐based binning reduced image artifacts, it also underestimated the full range of motion, partly because it does not use the full range of breathing data for reconstruction. 61 The irony is that ITV delineation with (phase‐based) 4DCT has already been shown to result in large variation because of irregular breathing in a simulation study. 62 In short, coupled with the relatively short acquisition time of 4DCT, irregular breathing of patients is not going to be resolved by incremental improvement of 4DCT, including different binning techniques. In principle, methods capable of long acquisition time, including 5DCT 32 and 4DMRI, 41 could help mitigate the problem. Patient training, coaching, and feedback have also been shown to be practical ways to remove/reduce the breathing irregularity.
Certainly, coaching or not, there is still concern that the 4DCT simulation may not represent the patient's breathing pattern during treatment. Persson et al. 63 suggested that large interfraction variation is presented in breathing amplitude irrespective of audio coaching. They suggested that daily image guidance for verification of respiratory pattern and tumor motion should be performed, which I agree. It is probably outside of this debate to go into more detail about patient verification imaging and its relationship with 4DCT, other than pointing out that fundamentally, improving 4DCT will not impact its ability to predict how a patient is going to breathe during treatment.
All these being said, I believe there is room for 4DCT to improve, but there are limits and inherent uncertainties with 4DCT. Physicists must understand these limits and adequately handle the uncertainties associated with 4DCT.
AUTHOR CONTRIBUTION
ET and HL contributed equally to the manuscript writing. YR contributed to topic conception and manuscript writing.
CONFLICT OF INTEREST STATEMENT
The authors declare no conflicts of interest.
ACKNOWLEDGMENTS
The authors have nothing to report.
Tryggestad E, Li H, Rong Y. 4DCT is long overdue for improvement. J Appl Clin Med Phys. 2023;24:e13933. 10.1002/acm2.13933
Erik Tryggestad and Heng Li contributed equally to the manuscript.
REFERENCES
- 1. Taguchi K. Temporal resolution and the evaluation of candidate algorithms for four‐dimensional CT. Med Phys. 2003;30(4):640‐650. [DOI] [PubMed] [Google Scholar]
- 2. Bezjak A, Paulus R, Gaspar LE, et al. Safety and efficacy of a five‐fraction stereotactic body radiotherapy schedule for centrally located non‐small‐cell lung cancer: NRG Oncology/RTOG 0813 trial. J Clin Oncol. 2019;37(15):1316‐1325. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Videtic GM, Paulus R, Singh AK, et al. Long‐term follow‐up on NRG Oncology RTOG 0915 (NCCTG N0927): a randomized phase 2 study comparing 2 stereotactic body radiation therapy schedules for medically inoperable patients with stage i peripheral non‐small cell lung cancer. Int J Radiat Oncol Biol Phys. 2019;103(5):1077‐1084. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Groh BA, Siewerdsen JH, Drake DG, Wong JW, Jaffray DA. A performance comparison of flat‐panel imager‐based MV and kV cone‐beam CT. Med Phys. 2002;29(6):967‐975. [DOI] [PubMed] [Google Scholar]
- 5. Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA. Flat‐panel cone‐beam computed tomography for image‐guided radiation therapy. Int J Radiat Oncol Biol Phys. 2002;53(5):1337‐1349. [DOI] [PubMed] [Google Scholar]
- 6. Ford EC, Mageras GS, Yorke E, Ling CC. Respiration‐correlated spiral CT: a method of measuring respiratory‐induced anatomic motion for radiation treatment planning. Med Phys. 2003;30(1):88‐97. [DOI] [PubMed] [Google Scholar]
- 7. Keall PJ, Mageras GS, Balter JM, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006;33(10):3874‐3900. [DOI] [PubMed] [Google Scholar]
- 8. Landberg T, Chavaudra J , Dobbs J, et al. ICRU Report 62: prescribing, Recording and Reporting Photon Beam Therapy (Supplment to ICRU Report 50). 1999;32(1):1‐55. [Google Scholar]
- 9. Slotman BJ, Lagerwaard FJ, Senan S. 4D imaging for target definition in stereotactic radiotherapy for lung cancer. Acta Oncol. 2006;45(7):966‐972. [DOI] [PubMed] [Google Scholar]
- 10. Wagman R, Yorke E, Ford E, et al. Respiratory gating for liver tumors: use in dose escalation. Int J Radiat Oncol Biol Phys. 2003;55(3):659‐668. [DOI] [PubMed] [Google Scholar]
- 11. Kini VR, Vedam SS, Keall PJ, Patil S, Chen C, Mohan R. Patient training in respiratory‐gated radiotherapy. Med Dosim. 2003;28(1):7‐11. [DOI] [PubMed] [Google Scholar]
- 12. van Herk M, Remeijer P, Rasch C, et al. The probability of correct target dosage: dose‐population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47(4):1121‐1135. [DOI] [PubMed] [Google Scholar]
- 13. Lujan AE, Larsen EW, Balter JM, et al. A method for incorporating organ motion due to breathing into 3D dose calculations. Med Phys. 1999;26(5):715‐720. [DOI] [PubMed] [Google Scholar]
- 14. McCarter SD, Beckham WA. Evaluation of the validity of a convolution method for incorporating tumour movement and set‐up variations into the radiotherapy treatment planning system. Phys Med Biol. 2000;45(4):923‐931. [DOI] [PubMed] [Google Scholar]
- 15. Chetty IJ, Rosu M, Tyagi N, et al. A fluence convolution method to account for respiratory motion in three‐dimensional dose calculations of the liver: a Monte Carlo study. Med Phys. 2003;30(7):1776‐1780. [DOI] [PubMed] [Google Scholar]
- 16. Trofimov A, Rietzel E, Lu H‐M, et al. Temporo‐spatial IMRT optimization: concepts, implementation and initial results. Phys Med Biol. 2005;50(12):2779‐2798. [DOI] [PubMed] [Google Scholar]
- 17. Rietzel E, Chen GTY, Choi NC, et al. Four‐dimensional image‐based treatment planning: target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys. 2005;61(5):1535‐1550. [DOI] [PubMed] [Google Scholar]
- 18. Lee L, Ma Y, Ye Y, et al. Conceptual formulation on four‐dimensional inverse planning for intensity modulated radiation therapy. Phys Med Biol. 2009;54(13):N255‐N266. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19. Roland T, Hales R, McNutt T, et al. A method for deriving a 4D‐interpolated balanced planning target for mobile tumor radiotherapy. Med Phys. 2012;39(1):195‐205. [DOI] [PubMed] [Google Scholar]
- 20. Cai J, Read PW, Altes TA, et al. Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI. Phys Med Biol. 2007;52(2):365‐273. [DOI] [PubMed] [Google Scholar]
- 21. Tryggestad E, Flammang A, Hales R, et al. 4D tumor centroid tracking using orthogonal 2D dynamic MRI: implications for radiotherapy planning. Med Phys. 2013;40(9):091712. [DOI] [PubMed] [Google Scholar]
- 22. Zhang P, Hugo GD, Yan D. Planning study comparison of real‐time target tracking and four‐dimensional inverse planning for managing patient respiratory motion. Int J Radiat Oncol Biol Phys. 2008;72(4):1221‐1227. [DOI] [PubMed] [Google Scholar]
- 23. Richter A, Baier K, Meyer J, et al. Influence of increased target dose inhomogeneity on margins for breathing motion compensation in conformal stereotactic body radiotherapy. BMC Med Phys. 2008;8:5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Brock KK. Results of a multi‐institution deformable registration accuracy study (MIDRAS). Int J Radiat Oncol Biol Phys. 2010;76(2):583‐596. [DOI] [PubMed] [Google Scholar]
- 25. Brock KK, Mutic S, McNutt TR, et al. Use of image registration and fusion algorithms and techniques in radiotherapy: report of the AAPM Radiation Therapy Committee Task Group No. 132. Med Phys. 2017;44(7):e43‐e76. [DOI] [PubMed] [Google Scholar]
- 26. Bert C, Grözinger SO, Rietzel E. Quantification of interplay effects of scanned particle beams and moving targets. Phys Med Biol. 2008;53(9):2253‐2265. [DOI] [PubMed] [Google Scholar]
- 27. Li H, Dong L, Bert C, et al. AAPM Task Group Report 290: respiratory motion management for particle therapy. Med Phys. 2022;49(4):e50‐e81. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28. Olsen JR, Lu W, Hubenschmidt JP, et al. Effect of novel amplitude/phase binning algorithm on commercial four‐dimensional computed tomography quality. Int J Radiat Oncol Biol Phys. 2008;70(1):243‐252. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29. Tryggestad E, Flammang A, Han‐Oh S, et al. Respiration‐based sorting of dynamic MRI to derive representative 4D‐MRI for radiotherapy planning. Med Phys. 2013;40(5):051909. [DOI] [PubMed] [Google Scholar]
- 30. Hui C, Suh Y, Robertson D, et al. Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features. Med Phys. 2015;42(7):4338‐4348. [DOI] [PubMed] [Google Scholar]
- 31. Martin R, Pan T. Target volume and artifact evaluation of a new data‐driven 4D CT. Pract Radiat Oncol. 2017;7(5):e345‐e354. [DOI] [PubMed] [Google Scholar]
- 32. Low DA, White BM, Lee PP, et al. A novel CT acquisition and analysis technique for breathing motion modeling. Phys Med Biol. 2013;58(11):L31‐L36. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Thomas D, Lamb J, White B, et al. A novel fast helical 4D‐CT acquisition technique to generate low‐noise sorting artifact‐free images at user‐selected breathing phases. Int J Radiat Oncol Biol Phys. 2014;89(1):191‐198. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Dou TH, Thomas DH, O'Connell DP, et al. A method for assessing ground‐truth accuracy of the 5DCT technique. Int J Radiat Oncol Biol Phys. 2015;93(4):925‐933. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Yeoh H, Hong SH, Ahn C, et al. Deep learning algorithm for simultaneous noise reduction and edge sharpening in low‐dose CT images: a pilot study using lumbar spine CT. Korean J Radiol. 2021;22(11):1850‐1857. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Kobayashi T, Nishii T, Umehara K, et al. Deep learning‐based noise reduction for coronary CT angiography: using four‐dimensional noise‐reduction images as the ground truth. Acta Radiol. 2022:2841851221141656. [DOI] [PubMed] [Google Scholar]
- 37. von Siebenthal M, Székely G, Gamper U, et al. 4D MR imaging of respiratory organ motion and its variability. Phys Med Biol. 2007;52(6):1547‐1564. [DOI] [PubMed] [Google Scholar]
- 38. Hu Y, Caruthers SD, Low DA, et al. Respiratory amplitude guided 4‐dimensional magnetic resonance imaging. Int J Radiat Oncol Biol Phys. 2013;86(1):198‐204. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39. Vedam S, Keall PJ, Kini VR, et al. Acquiring a four‐dimensional computed tomography dataset using an external respiratory signal. Physics in Medicine & Biology. 2002;48(1):45. [DOI] [PubMed] [Google Scholar]
- 40. Pan T, Lee T‐Y, Rietzel E, et al. 4D‐CT imaging of a volume influenced by respiratory motion on multi‐slice CT. Med Phys. 2004;31(2):333‐340. [DOI] [PubMed] [Google Scholar]
- 41. Vergalasova I, Cai J. A modern review of the uncertainties in volumetric imaging of respiratory‐induced target motion in lung radiotherapy. Med Phys. 2020;47(10):e988‐e1008. [DOI] [PubMed] [Google Scholar]
- 42. Sentker T, Schmidt V, Ozga A‐K, et al. 4D CT image artifacts affect local control in SBRT of lung and liver metastases. Radiother Oncol. 2020;148:229‐234. [DOI] [PubMed] [Google Scholar]
- 43. Castillo SJ, Castillo R, Castillo E, et al. Evaluation of 4D CT acquisition methods designed to reduce artifacts. J Appl Clin Med Phys. 2015;16(2):23‐32. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Zhang Y, Yang J, Zhang L, et al. Modeling respiratory motion for reducing motion artifacts in 4D CT images. Med Phys. 2013;40(4):041716. [DOI] [PubMed] [Google Scholar]
- 45. Mutaf Y, Antolak J, Brinkmann D. The impact of temporal inaccuracies on 4DCT image quality. Med Phys. 2007;34(5):1615‐1622. [DOI] [PubMed] [Google Scholar]
- 46. Pan T, Sun X, Luo D. Improvement of the cine‐CT based 4D‐CT imaging. Med Phys. 2007;34(11):4499‐4503. [DOI] [PubMed] [Google Scholar]
- 47. Antony R, Lonski P, Ungureanu E, et al. Independent review of 4DCT scans used for SABR treatment planning. J Appl Clin Med Phys. 2020;21(3):62‐67. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48. Lambrecht M, Sonke J‐J, Nestle U, et al. Quality assurance of four‐dimensional computed tomography in a multicentre trial of stereotactic body radiotherapy of centrally located lung tumours. Phys Imaging Radiat Oncol. 2018;8:57‐62. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49. Hurkmans CW, van Lieshout M, Schuring D, et al. Quality assurance of 4D‐CT scan techniques in multicenter phase III trial of surgery versus stereotactic radiotherapy (radiosurgery or surgery for operable early stage (stage 1A) non‐small‐cell lung cancer [ROSEL] study). Int J Radiat Oncol Biol Phys. 2011;80(3):918‐927. [DOI] [PubMed] [Google Scholar]
- 50. Polizzi M, Kim S, Rosu‐Bubulac M. A comprehensive quality assurance procedure for 4D CT commissioning and periodic QA. J Appl Clin Med Phys. 2022;23(11):e13764. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51. Flampouri S, Jiang SB, Sharp GC, et al. Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D‐CT data and Monte Carlo simulations. Phys Med Biol. 2006;51(11):2763. [DOI] [PubMed] [Google Scholar]
- 52. Liu G, Hu F, Ding X, et al. Simulation of dosimetry impact of 4DCT uncertainty in 4D dose calculation for lung SBRT. Radiat Oncol. 2019;14(1):1‐12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53. Cai J, Read PW, Larner JM, et al. Reproducibility of interfraction lung motion probability distribution function using dynamic MRI: statistical analysis. Int J Radiat Oncol Biol Phys. 2008;72(4):1228‐1235. [DOI] [PubMed] [Google Scholar]
- 54. Ozhasoglu C, Murphy MJ. Issues in respiratory motion compensation during external‐beam radiotherapy. Int J Radiat Oncol Biol Phys. 2002;52(5):1389‐1399. [DOI] [PubMed] [Google Scholar]
- 55. Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real‐time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys. 2002;53(4):822‐834. [DOI] [PubMed] [Google Scholar]
- 56. Shirato H, Seppenwoolde Y, Kitamura K, et al. Intrafractional tumor motion: lung and liver. Semin Radiat Oncol. 2004;14(1):10‐18. [DOI] [PubMed] [Google Scholar]
- 57. Gierga DP, Chen GTY, Kung JH, et al. Quantification of respiration‐induced abdominal tumor motion and its impact on IMRT dose distributions. Int J Radiat Oncol Biol Phys. 2004;58(5):1584‐1495. [DOI] [PubMed] [Google Scholar]
- 58. Yamamoto T, Langner U, Loo BW, et al. Retrospective analysis of artifacts in four‐dimensional CT images of 50 abdominal and thoracic radiotherapy patients. Int J Radiat Oncol Biol Phys. 2008;72(4):1250‐1258. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59. Werner R, Hofmann C, Mücke E, et al. Reduction of breathing irregularity‐related motion artifacts in low‐pitch spiral 4D CT by optimized projection binning. Radiat Oncol. 2017;12(1):100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60. Li G, Caraveo M, Wei J, et al. Rapid estimation of 4DCT motion‐artifact severity based on 1D breathing‐surrogate periodicity. Med Phys. 2014;41(11):111717. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61. Li H, Noel C, Garcia‐Ramirez J, et al. Clinical evaluations of an amplitude‐based binning algorithm for 4DCT reconstruction in radiation therapy. Med Phys. 2012;39(2):922‐932. [DOI] [PubMed] [Google Scholar]
- 62. James SS, Mishra P, Hacker F, et al. Quantifying ITV instabilities arising from 4DCT: a simulation study using patient data. Phys Med Biol. 2012;57(5):L1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63. Persson GF, Nygaard DE, Olsen M, et al. Can audio coached 4D CT emulate free breathing during the treatment course? Acta Oncol (Madr). 2008;47(7):1397‐1405. [DOI] [PubMed] [Google Scholar]
