Skip to main content
. 2022 Oct 20;20(1):207–219. doi: 10.1007/s13311-022-01303-x

Fig. 4.

Fig. 4

Correlation between NRS percentage changes after rTMS and tDCS. Correlation between maximal percentage changes of numerical pain reports (NRS) after rTMS and tDCS. Although NRS changes to both techniques were correlated, the slope of the regression line was significantly skewed towards rTMS, with confidence limits (dotted lines) which did not reach the theoretical equivalence line of β = 1. Abbreviations: rTMS, high-frequency repetitive transcranial magnetic stimulation; tDCS, transcranial direct current stimulation; NRS, numerical rating scale