Abstract
In a controlled, randomized trial in 45 cataract operations a new synthetic absorbable suture (8-0 monofilament Vicryl, made by Ethicon), was compared with monofilament nylon or virgin silk normally used. There was a higher incidence of early complications-hyphaema, shallow anterior chamber, and choroidal detachment (15-4 per cent v. 0 per cent)-with the absorbable suture. But these differences were not significant at the 0-05 level and might well disappear with more operative experience, particularly the modified technique of knot-tying. In handling qualities Vicryl was superior to both 10-0 monofilament nylon and 8-0 virgin silk with the exception of knot-tying, in which it was inferior to 8-0 virgin silk. Vicryl is considered to be a useful absorbable suture in cataract surgery but knot-tying requires modification of technique.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Cox A. G., Simpson J. E. Letter: Polyglycolic-acid suture material in skin closure. Lancet. 1975 Feb 22;1(7904):452–452. doi: 10.1016/s0140-6736(75)91520-2. [DOI] [PubMed] [Google Scholar]
- Munton C. G., Phillips C. I., Martin B., Bartholomew R. S., Capperauld I. Vicryl (Polyglactin 910): a new synthetic absorbable suture in ophthalmic surgery. A preliminary study. Br J Ophthalmol. 1974 Nov;58(11):941–947. doi: 10.1136/bjo.58.11.941. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Watts G. T. Letter: Sutures for skin closure. Lancet. 1975 Mar 8;1(7906):581–581. doi: 10.1016/s0140-6736(75)91608-6. [DOI] [PubMed] [Google Scholar]