Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- COOLEY D. A., BELMONTE B. A., DE BAKEY M. E., LATSON J. R. Temporary extracorporeal circulation in the surgical treatment of cardiac and aortic disease; report of 98 cases. Ann Surg. 1957 Jun;145(6):898-912; discussions, 913-4. doi: 10.1097/00000658-195706000-00012. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DEWALL R. A., WARDEN H. E., VARCO R. L., LILLEHEI C. W. The helix reservoir pump-oxygenator. Surg Gynecol Obstet. 1957 Jun;104(6):699–710. [PubMed] [Google Scholar]
- GIANNELLI S., Jr, MOLTHAN M. F., BEST R. J., DULL J. A., KIRBY C. K. The effects produced by various types of pump-oxygenators during two-hour partial infusions in dogs. J Thorac Surg. 1957 Nov;34(5):563–569. [PubMed] [Google Scholar]
- LILLEHEI C. W., WARDEN H. E., DEWALL R. A., STANLEY P., VARCO R. L. Cardiopulmonary by-pass in surgical treatment of congenital or acquired cardiac disease; use in three hundred five patients. AMA Arch Surg. 1957 Dec;75(6):928–945. doi: 10.1001/archsurg.1957.01280180060009. [DOI] [PubMed] [Google Scholar]
- MALONEY J. V., Jr, LONGMIRE W. P., Jr, SCHMUTZER K. J., MARABLE S. A., RASCHKE E., WATANABE Y., LOBPREIS E. L., ARZOUMAN J. E. An experimental and clinical comparison of the bubble dispersion and stationary screen pump oxygenators. Surg Gynecol Obstet. 1958 Nov;107(5):577–587. [PubMed] [Google Scholar]
- OWENS G., ADAMS J. E., DAWSON R. E., LANCE E. M., SAWYERS J. L., SCOTT H. W., Jr Observed central nervous system responses during experimental employment of various pump-oxygenators. Surgery. 1958 Jul;44(1):240–254. [PubMed] [Google Scholar]
- PENRY J. K., CORDELL A. R., JOHNSTON F. R., NETSKY M. G. Experimental cerebral embolism with anti-foam A. J Thorac Surg. 1959 Mar;37(3):342–351. [PubMed] [Google Scholar]
- REED W. A., KITTLE C. F. Observations on toxicity and use of antifoam A. AMA Arch Surg. 1959 Feb;78(2):220–225. doi: 10.1001/archsurg.1959.04320020042008. [DOI] [PubMed] [Google Scholar]
- SWANK R. L., HAIN R. F. The effect of different sized emboli on the vascular system and parenchyma of the brain. J Neuropathol Exp Neurol. 1952 Jul;11(3):280–299. doi: 10.1097/00005072-195207000-00005. [DOI] [PubMed] [Google Scholar]
- YATES P. O., CASSIE A. B., DARK J. F., JACK G. D., RIDDELL A. G. The detection of antifoam emboli following perfusion with a heart-lung machine. Lancet. 1959 Jan 17;1(7064):130–130. doi: 10.1016/s0140-6736(59)90008-x. [DOI] [PubMed] [Google Scholar]