Skip to main content
Thorax logoLink to Thorax
. 1964 Nov;19(6):503–506. doi: 10.1136/thx.19.6.503

A Simple Versatile Pulse Duplicator

C G Duran 1,1, A J Gunning 1, T McMillan 1
PMCID: PMC1018869  PMID: 14238387

Full text

PDF
503

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. AUSTEN W. G., SHAW R. S., SCANNELL J. G., THURLBECK W. M. Postmortem study of the technique of aortic valvulotomy in calcific aortic stenosis by quantitative examination of valvular function by perfusion. J Thorac Surg. 1958 Oct;36(4):571–583. [PubMed] [Google Scholar]
  2. BARNARD C. N., McKENZIE M. B., DE VILLIERS D. R. The electrical pulse duplicator--its use in testing valve prostheses with special reference to the aortic and mitral valves. S Afr J Med Sci. 1959 Oct 10;33:859–862. [PubMed] [Google Scholar]
  3. BJORK V. O., INTONTI F., MEISSL A. A mechanical pulse duplicator for testing prosthetic mitral and aortic valves. Thorax. 1962 Sep;17:280–283. doi: 10.1136/thx.17.3.280. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. DAVILA J. C., TROUT R. G., SUNNER J. E., GLOVER R. P. A simple mechanical pulse duplicator for cinematography of cardiac valves in action. Ann Surg. 1956 Apr;143(4):544–551. doi: 10.1097/00000658-195604000-00017. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. GOODALE F., Jr, SHAW R. S. Functional examination of the heart at autopsy; preliminary report. N Engl J Med. 1955 Oct 27;253(17):719–721. doi: 10.1056/NEJM195510272531703. [DOI] [PubMed] [Google Scholar]
  6. HARKEN D. E., SOROFF H. S., TAYLOR W. J., LEFEMINE A. A., GUPTA S. K., LUNZER S. Partial and complete prostheses in aortic insufficiency. J Thorac Cardiovasc Surg. 1960 Dec;40:744–762. [PubMed] [Google Scholar]
  7. HUDSPETH A. S., CORDELL A. R. A method for testing aortic valvular function during open repair. J Thorac Cardiovasc Surg. 1963 Jun;45:813–816. [PubMed] [Google Scholar]
  8. KELLEY R. R., GOODALE F., Jr, CASTLEMAN B. The dynamics of rheumatic and calcific aortic valve disease: a postmortem study with the use of the pulse duplicator. Circulation. 1960 Sep;22:365–375. doi: 10.1161/01.cir.22.3.365. [DOI] [PubMed] [Google Scholar]
  9. MARX T. I., BALDWIN B. R., KITTLE C. F. A cardiovascular simulator for the evaluation of prosthetic aortic valves. J Thorac Cardiovasc Surg. 1959 Sep;38:412–418. [PubMed] [Google Scholar]
  10. McMILLAN I. K. Aortic stenosis; a post-mortem cinephotographic study of valve action. Br Heart J. 1955 Jan;17(1):56–62. doi: 10.1136/hrt.17.1.56. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. SMITH H. L., ESSEX H. E., BALDES E. J. A study of the movements of heart valves and of heart sounds. Ann Intern Med. 1950 Dec;33(6):1357–1359. doi: 10.7326/0003-4819-33-6-1357. [DOI] [PubMed] [Google Scholar]
  12. STARKEY W. L., SIRAK H. D., COLLINS J. A., HAGAN B. T. THE DESIGN AND DEVELOPMENT OF A CARDIAC SIMULATOR FOR THE EVALUATION OF HEART-VALVE PROSTHESIS. J Thorac Cardiovasc Surg. 1963 Aug;46:207–211. [PubMed] [Google Scholar]
  13. STARR I., SCHNABEL T. G., Jr, MAYOCK R. L. Studies made by simulating systole at necropsy. II. Experiments on the relation of cardiac and peripheral factors to the genesis of the pulse wave and the ballistocardiogram. Circulation. 1953 Jul;8(1):44–61. doi: 10.1161/01.cir.8.1.44. [DOI] [PubMed] [Google Scholar]
  14. WESSEL H. U., KEZDI P., LEWIS F. J. A simple external pulse duplicator for observation of cardiac valvular action. J Thorac Cardiovasc Surg. 1962 Apr;43:513–516. [PubMed] [Google Scholar]

Articles from Thorax are provided here courtesy of BMJ Publishing Group

RESOURCES