Skip to main content
Elsevier - PMC COVID-19 Collection logoLink to Elsevier - PMC COVID-19 Collection
. 2023 May 24;165:105496. doi: 10.1016/j.jcv.2023.105496

Direct comparison of clinical diagnostic sensitivity of saliva from buccal swabs versus combined oro-/nasopharyngeal swabs in the detection of SARS-CoV-2 B.1.1.529 Omicron

Andreas Puyskens a, Janine Michel a, Anna Stoliaroff-Pepin b, Fatimanur Bayram a, Akin Sesver a, Ole Wichmann b, Thomas Harder b, Lars Schaade a, Andreas Nitsche a, Caroline Peine b,
PMCID: PMC10207859  PMID: 37269606

Abstract

Background/Purpose

While current guidelines recommend the use of respiratory tract specimens for the direct detection of SARS-CoV-2 infection, saliva has recently been suggested as preferred sample type for the sensitive detection of SARS-CoV-2 B.1.1.529 (Omicron). By comparing saliva collected using buccal swabs and oro-/nasopharyngeal swabs from patients hospitalized due to COVID-19, we aimed at identifying potential differences in virus detection sensitivity between these sample types.

Methods

We compare the clinical diagnostic sensitivity of paired buccal swabs and combined oro-/nasopharyngeal swabs from hospitalized, symptomatic COVID-19 patients collected at median six days after symptom onset by real-time polymerase chain reaction (PCR) and antigen test.

Results

Of the tested SARS-CoV-2 positive sample pairs, 55.8% were identified as SARS-CoV-2 Omicron BA.1 and 44.2% as Omicron BA.2. Real-time PCR from buccal swabs generated significantly higher quantification cycle (Cq) values compared to those from matched combined oro-/nasopharyngeal swabs and resulted in an increased number of false-negative PCR results. Reduced diagnostic sensitivity of buccal swabs by real-time PCR was observed already at day one after symptom onset. Similarly, antigen test detection rates were reduced in buccal swabs compared to combined oro-/nasopharyngeal swabs.

Conclusion

Our results suggest reduced clinical diagnostic sensitivity of saliva collected using buccal swabs when compared to combined oro-/nasopharyngeal swabs in the detection of SARS-CoV-2 Omicron in symptomatic individuals.

Keywords: SARS-CoV-2, B.1.1.529 (Omicron), Clinical diagnostic sensitivity, Saliva, Buccal swab sampling

Graphical abstract

Image, graphical abstract

1. Background

Respiratory tract specimens, such as those collected by oro-/nasopharyngeal swabs, are currently recommended for the direct detection of SARS-CoV-2 by real-time polymerase chain reaction (PCR) and most antigen tests [1], [2], [3]. In November 2021, a new SARS-CoV-2 variant B.1.1.529 (Omicron) emerged and spread rapidly around the globe [4]. Several studies have suggested an improved sensitivity of saliva over upper respiratory tract specimens in the detection of SARS-CoV-2 Omicron and other variants by real-time PCR [5], [6], [7], [8]. Saliva could offer an appealing alternative to oro- and/or nasopharyngeal swabs as sample collection is considered less invasive and could potentially be easily performed by caretakers and patients themselves [9]. Hence, the aim of this study was to assess the diagnostic performance of saliva collected using buccal swabs versus oro-/nasopharyngeal swab samples in the detection of the SARS-CoV-2 Omicron variant. To do so, we compared the clinical diagnostic sensitivity of matched buccal and combined oro-/nasopharyngeal swabs collected from hospitalized, symptomatic individuals by real-time PCR and antigen test.

2. Methods

2.1. Study design and sample collection

Clinical specimens were collected as part of the COViK study conducted by the Robert Koch Institute in collaboration with the Paul-Ehrlich-Institut [[10], [11]]. Thirteen hospitals across Germany served as study sites. Samples were collected between January and March 2022. Sampling was performed on symptomatic individuals on day six (median) after symptom onset. Trained study nurses performed sampling, using swabs of identical design (eSwab™, COPAN Diagnostics, Murrieta, CA, USA) for both buccal and combined oro-/nasopharyngeal sample collection. A total of 107 matched sample pairs consisting of one buccal and one combined oro-/nasopharyngeal swab were collected. Collection of saliva using buccal swabs was performed immediately before collection of the combined oro-/nasopharyngeal swab. Prior to buccal swabbing participants were asked to think of their favorite food for approximately 0.5–1.0 minute to stimulate saliva flow. Buccal swab samples were collected by streaking both the left and right lower inner cheek for 30 seconds each while applying light pressure to the swab and rotating it around its own axis allowing for full saturation of the swab tip with saliva. Subsequently, a fresh swab was used for oropharyngeal sampling directly followed by nasopharyngeal sampling using the same swab. After sample collection swabs were transferred to their respective collection tubes containing transport medium. Matched buccal and combined oro-/nasopharyngeal swabs were shipped together at 2–8 °C and were stored at 4 °C upon arrival, ensuring identical transport and storage conditions for matched samples. Time from sampling to result were 2 days (median), while nearly half of all samples (47.93%) required only 1 day from sampling to result.

2.2. RNA extraction and real-time PCR analysis

To extract viral RNA from samples, 140 µl of swab-containing transport medium were manually inactivated using AVL+Ethanol and extracted using the QIAamp Viral RNA Mini kit (QIAGEN, Hilden, Germany) according to manufacturer's instructions. SARS-CoV-2 RNA was detected by real-time PCR using two separate assays, each targeting a distinct SARS-CoV-2 genomic region (E-gene and Orf1ab) as has been described previously [12]. For the identification of SARS-CoV-2 variants, PCR positive samples were further analyzed using variant-specific PCR assays and/or next-generation sequencing [13].

2.3. Antigen testing

For antigen detection, the Panbio™ COVID-19 Ag Rapid Test Device (Abbott Rapid Diagnostics, Jena, Germany) was used. For testing, 50 µl of the native swab-containing transport medium were transferred directly to the test-specific extraction buffer and subsequent testing was performed according to manufacturer's instructions. Results were analyzed independently by two trained laboratory technicians. If results were not in agreement a third person analyzed the test and the result in favor was noted. All antigen tests included in this study showed a visible control line.

3. Results

First, we compared clinical diagnostic sensitivities for the detection of SARS-CoV-2 Omicron from matched buccal and combined oro-/nasopharyngeal swabs by real-time PCR. In total, 107 matched sample pairs were collected at median six days after symptom onset from previously confirmed SARS-CoV-2 positive hospitalized, symptomatic individuals. Of those, 11 sample pairs (10.28%) tested PCR negative for SARS-CoV-2 in both buccal and oro-/nasopharyngeal swabs. Of the positive samples, all were identified as the SARS-CoV-2 Omicron variant (55.8% BA.1 and 44.2% BA.2). Only two oro-/nasopharyngeal swabs (1.87%) tested PCR negative while the matched buccal swabs tested PCR positive (Fig. 1 A). In contrast, 17 buccal swabs (15.89%) tested PCR negative, while the matched oro-/nasopharyngeal swabs tested PCR positive, resulting in a higher number of false-negative real-time PCR results for buccal swabs in comparison to combined oro-/nasopharyngeal swabs (Fig. 1A). Comparing only those sample pairs that tested PCR positive for both buccal and oro-/nasopharyngeal swab, real-time PCR from buccal swabs resulted in significantly higher Cq values compared to matching oro-/nasopharyngeal swabs with a difference in means for E-gene of 7.36 Cq (CI 6.23 to 8.5) and Orf1ab of 7.2 Cq (CI 6.1 to 8.3) (Fig. 1B). Overall, lower Cq values in buccal swabs were observed for only 7 (E-gene) and 8 (Orf1ab) sample pairs. Notably, reduced performance of buccal swabs was observed for both SARS-CoV-2 Omicron BA.1 and BA.2 (Supplementary Fig. 1). Higher Cq values in buccal swabs were detected as early as day one to two after symptom onset (Fig. 2 ). We also tested detection performance of matched buccal and combined oro-/nasopharyngeal swabs by antigen test. While the positive detection rate by antigen test for combined oro-/nasopharyngeal swab samples was 58.44% (45/77 samples), positive detection rate for buccal swab samples was only 3.9% (3/77 samples) (Fig. 3 ).

Fig. 1.

Fig 1

Comparison of SARS-CoV-2 B1.1.529 Omicron detection performance of matched buccal and combined oro-/nasopharyngeal swabs by real-time PCR. A Comparison of cycle threshold (Cq) values for two distinct genomic regions of SARS-CoV-2 (E-gene and Orf1ab) of matched buccal and combined oro-/nasopharyngeal swabs (ONS) by quantitative real-time PCR (RKI/ZBS1 SARS-CoV-2 protocol, Michel et al. Virol J (2021) 18:110); n = 107. B Estimation plot of SARS-CoV-2 positive sample pairs with Cq values ≤45; n = 77. Line at mean with 95% Confidence Interval; Paired t-test, p **** <0,0001.

Fig. 2.

Fig 2

Comparison of real-time PCR results from buccal and combined oro-/nasopharyngeal swabs at different time periods after symptom onset. Comparison of cycle threshold (Cq) values for two distinct genomic regions of SARS-CoV-2 (E-gene and Orf1ab) of matched buccal and combined oro-/nasopharyngeal swabs (ONS) by quantitative real-time PCR (RKI/ZBS1 SARS-CoV-2 protocol, Michel et al. Virol J (2021) 18:110) at different days post (d.p.) symptom onset. Data displayed as Tukey box plot.

Fig. 3.

Fig 3

Comparison of SARS-CoV-2 B.1.1.529 Omicron detection performance of matched buccal and combined oro-/nasopharyngeal swabs by antigen test. PCR positive buccal and combined oro-/nasopharyngeal (ONS) sample pairs (n = 77) were tested using the Panbio™ COVID-19 Ag Rapid Test Device. Shown are the number of positive and negative antigen test results. All tests showed a visible control line.

4. Discussion

In this study, we observed reduced clinical diagnostic sensitivity of saliva collected using buccal swabs in comparison to matched combined oro-/nasopharyngeal swabs in the detection of SARS-CoV-2 Omicron (BA.1 and BA.2). Several studies on the sensitivity of saliva versus respiratory tract specimens for the detection of SARS-CoV-2, including the Omicron variant, have been conducted, leading to mixed and in parts contradictory results [[5], [6], [7], [8],[14], [15], [16]]. In this study, samples were collected from hospitalized, symptomatic individuals who had previously been confirmed to be SARS-CoV-2 positive, resulting in sample collection at median six days after initial symptom onset. We observed that around 10% of initially PCR positive individuals were negative by the time of the second PCR testing, probably due to the relatively late time of sampling. Despite the majority of samples being collected at late stages of infection, higher Cq values in buccal swabs were detected already from day one to two after symptom onset in this limited data set. In a recent study, Lai et al. compared saliva and nasal swabs from close contacts of COVID-19 cases over time and found that, in those contacts who became infected, saliva samples showed higher viral loads compared to those in nasal swabs from three days prior to symptom onset to two days after symptom onset [17]. In contrast, two days after symptom onset there was a trend towards improved sensitivity with nasal swabs compared to saliva, indicating the importance of time of sampling for subsequent specimen sensitivity [17]. Furthermore, we applied buccal swabbing to collect saliva using swabs of identical design for both the collection of saliva and oro-/nasopharyngeal specimens. Using identical swabs enabled direct comparison between specimen types by ensuring identical conditions for transport and handling during all downstream manipulations, including RNA extraction. While the swabs used in this study are suitable for versatile applications, they are not specifically designed for buccal swabbing, which ultimately could impact saliva sensitivity. We did not assess other types of swabs and saliva sampling methods, such as drooling, spitting or sampling from specific salivary glands or other locations, which might further impact subsequent saliva sensitivity. Overall, factors such as the time of sampling and specific sampling methods are likely to play a critical role in the diagnostic sensitivity of saliva and might explain some of the differences found across studies.

In addition to real-time PCR, we also performed antigen testing using the Panbio™ COVID-19 antigen rapid test, which resulted in substantially reduced detection rates among buccal swab samples in comparison to combined oro-/nasopharyngeal swab samples. While reduced performance of this specific antigen test for the detection of SARS-CoV-2 Omicron is not predicted by the manufacturer due to the use of the nucleocapsid (N) protein as target antigen [18], it has previously been shown that the use of throat and saliva samples with the Panbio™ COVID-19 antigen rapid test led to poorer sensitivity compared to nasopharyngeal swab samples [19]. Although all swab samples in this study were subject to prior dilution in transport medium, it is not clear whether the reduced performance of buccal swab samples is due to a reduced concentration of N protein in buccal saliva or whether saliva is a suboptimal sample type for use in the Panbio™ COVID-19 antigen rapid test.

At the time of study, SARS-CoV-2 Omicron BA.1 and BA.2 were the dominant variants present in Germany [20], which is also reflected in our sample set. A study using ex vivo infections of different tissues found that SARS-CoV-2 Omicron BA.2 displayed increased replication competence in human nasal and bronchial tissues compared to Omicron BA.1 as well as the original SARS-CoV-2 wild-type strain and the Delta variant [21]. It remains to be elucidated how recently emerged and currently dominant variants of SARS-CoV-2 might affect diagnostic sensitivities of different specimen types.

Taken together, despite the reduced invasiveness and ease of sampling, the use of saliva collected by buccal swabs displays substantially reduced sensitivity in comparison to combined oro-/nasopharyngeal swab specimens for the detection of SARS-CoV-2 Omicron. This further highlights the importance to carefully consider time and context of sampling for choosing the optimal specimen type for diagnostics.

Ethical statement

The study obtained ethical approval by the Berliner Ärztekammer (Berlin Chamber of Physicians, Eth 20/40).

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgements

The authors thank all study nurses for the valuable contribution, namely Sawsanh Al-Ogaidi, Nancy Beetz, Belgin Esen, Rola Khalife, Katja Lange, Luise Mauer, Antje Micheel, Marlies Schmidt, Yvonne Weis, Franziska Weiser and Aysete Yencilek. The authors are grateful to Ursula Erikli for copyediting. This work was funded by the German Federal Ministry of Health.

Footnotes

Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.jcv.2023.105496.

Appendix. Supplementary materials

mmc1.docx (89.4KB, docx)

References

  • 1.RKI. Coronavirus SARS-CoV-2 - Hinweise zur Testung von Patientinnen und Patienten auf SARS-CoV-2, (n.d.). https://www.rki.de/DE/Content/InfAZ/N/Neuartiges_Coronavirus/Vorl_Testung_nCoV.html;jsessionid=3C0BAB0295736A1BE9A8524E9F42A5A6.internet071?nn=13490888#doc13490982bodyText1 (accessed December 6, 2022).
  • 2.Interim Guidelines for Clinical Specimens for COVID-19 | CDC, (n.d.). https://www.cdc.gov/coronavirus/2019-ncov/lab/guidelines-clinical-specimens.html (accessed December 6, 2022).
  • 3.Laboratory testing for 2019 novel coronavirus (2019-nCoV) in suspected human cases, (n.d.). https://www.who.int/publications/i/item/10665-331501 (accessed December 6, 2022).
  • 4.Hadfield J., Megill C., Bell S.M., Huddleston J., Potter B., Callender C., Sagulenko P., Bedford T., Neher R.A. NextStrain: real-time tracking of pathogen evolution. Bioinformatics. 2018;34:4121–4123. doi: 10.1093/bioinformatics/bty407. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Marais G., Hsiao N., Iranzadeh A., Doolabh D., Enoch A., Chu C., Williamson C., Brink A., Hardie D. Saliva swabs are the preferred sample for Omicron detection. MedRxiv. 2021 doi: 10.1101/2021.12.22.21268246. 2021.12.22.21268246. [DOI] [Google Scholar]
  • 6.Cornette M., Decaesteker B., Martens G.A., Vandecandelaere P., Jonckheere S. From Delta to Omicron SARS-CoV-2 variant: switch to saliva sampling for higher detection rate. J. Clin. Virol. Plus. 2022;2 doi: 10.1016/j.jcvp.2022.100090. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Jo S.J., Kim J., Kim S., Kim J., Kwon H., Kwon Y., Kim H., Kim H.H., Lee H., Kim S.W., Yeo C.D., Lee S.H., Lee J. Simple saliva sample collection for the detection of SARS-CoV-2 variants compared to nasopharyngeal swab sample. Arch. Pathol. Lab. Med. 2022:146. doi: 10.5858/arpa.2022-0298-sa. [DOI] [PubMed] [Google Scholar]
  • 8.Migueres M., Mansuy J.M., Vasseur S., Claverie N., Lougarre C., Soulier F., Trémeaux P., Izopet J. Omicron wave SARS-CoV-2 diagnosis: evaluation of saliva, anterior nasal, and nasopharyngeal swab samples. Microbiol. Spectr. 2022 doi: 10.1128/spectrum.02521-22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Bellagambi F.G., Lomonaco T., Salvo P., Vivaldi F., Hangouët M., Ghimenti S., Biagini D., Di Francesco F., Fuoco R., Errachid A. Saliva sampling: methods and devices. An overview. TrAC - Trends Anal. Chem. 2020;124 doi: 10.1016/j.trac.2019.115781. [DOI] [Google Scholar]
  • 10.Stoliaroff-Pepin A., Peine C., Herath T., Lachmann J., Perriat D., Dörre A., Nitsche A., Michel J., Grossegesse M., Hofmann N., Rinner T., Kohl C., Brinkmann A., Meyer T., Dorner B.G., Stern D., Treindl F., Hein S., Werel L., Hildt E., Gläser S., Schühlen H., Isner C., Peric A., Ghouzi A., Reichardt A., Janneck M., Lock G., Schaade L., Wichmann O., Harder T. Effectiveness of vaccines in preventing hospitalization due to COVID-19: a multicenter hospital-based case-control study, June 2021 to January 2022, Germany. Vaccine. 2023;41(2):290–293. doi: 10.1016/j.vaccine.2022.11.065. Epub 2022 Dec 2. PMID: 36509640; PMCID: PMC9715487. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Stoliaroff-Pepin A., Peine C., Herath T., Lachmann J., Hellenbrand W., Perriat D., Dörre A., Nitsche A., Michel J., Grossegesse M., Hofmann N., Rinner T., Kohl C., Brinkmann A., Meyer T., Stern D., Treindl F., Dorner B.G., Hein S., Werel L., Hildt E., Gläser S., Schühlen H., Isner C., Peric A., Ghouzi A., Reichardt A., Janneck M., Lock G., Huster D., Grünewald T., Schaade L., Wichmann O., Harder T. Vaccine effectiveness against severe COVID-19 during the Omicron wave in Germany: results from the COViK study. Infection. 2023:1–10. doi: 10.1007/s15010-023-02012-z. Epub ahead of print. PMID: 36913112; PMCID: PMC10009838. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Michel J., Neumann M., Krause E., Rinner T., Muzeniek T., Grossegesse M., Hille G., Schwarz F., Puyskens A., Förster S., Biere B., Bourquain D., Domingo C., Brinkmann A., Schaade L., Schrick L., Nitsche A. Resource-efficient internally controlled in-house real-time PCR detection of SARS-CoV-2. Virol. J. 2021;18 doi: 10.1186/s12985-021-01559-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Brinkmann A., Ulm S.L., Uddin S., Förster S., Seifert D., Oehme R., Corty M., Schaade L., Michel J., Nitsche A. AmpliCoV: rapid whole-genome sequencing using multiplex PCR amplification and real-time oxford nanopore MinION sequencing enables rapid variant identification of SARS-CoV-2. Front. Microbiol. 2021;12:1–9. doi: 10.3389/fmicb.2021.651151. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Uršič T., Kogoj R., Šikonja J., Roškarič D., Jevšnik Virant M., Bogovič P., Petrovec M. Performance of nasopharyngeal swab and saliva in detecting Delta and Omicron SARS-CoV-2 variants. J. Med. Virol. 2022;94:4704–4711. doi: 10.1002/jmv.27898. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Czumbel L.M., Kiss S., Farkas N., Mandel I., Hegyi A., Nagy Á., Lohinai Z., Szakács Z., Hegyi P., Steward M.C., Varga G. Saliva as a candidate for COVID-19 diagnostic testing: a meta-analysis. Front. Med. 2020;7:465. doi: 10.3389/fmed.2020.00465. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Jamal A.J., Mozafarihashjin M., Coomes E., Powis J., Li A.X., Paterson A., Anceva-Sami S., Barati S., Crowl G., Faheem A., Farooqi L., Khan S., Prost K., Poutanen S., Taylor M., Yip L., Zhong X.Z., McGeer A.J., Mubareka S., Coleman B.L., Chen D., Farshait N., Gold W., Kandel C.E., Katz K., Kozak R., Mazzulli T., Muller M., Opavsky A., Ostrowski M., Plevneshi A., Rau N., Ricciuto D., Richardson D., Rose D., Sales V., Walmsley S. Sensitivity of nasopharyngeal swabs and saliva for the detection of severe acute respiratory syndrome Coronavirus 2. Clin. Infect. Dis. 2021;72:1064–1066. doi: 10.1093/cid/ciaa848. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Lai J., German J., Hong F., Tai S.-H.S., McPhaul K.M., Milton D.K. Comparison of saliva and midturbinate swabs for detection of SARS-CoV-2. Microbiol. Spectr. 2022 doi: 10.1128/spectrum.00128-22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Evaluating Omicron and other COVID variants to ensure test effectiveness | Abbott Newsroom, (n.d.). https://www.abbott.com/corpnewsroom/diagnostics-testing/monitoring-covid-variants-to-ensure-test-effectiveness.html (accessed December 13, 2022).
  • 19.Stokes W., Berenger B.M., Portnoy D., Scott B., Szelewicki J., Singh T., Venner A.A., Turnbull L.A., Pabbaraju K., Shokoples S., Wong A.A., Gill K., Guttridge T., Proctor D., Hu J., Tipples G. Clinical performance of the Abbott Panbio with nasopharyngeal, throat, and saliva swabs among symptomatic individuals with COVID-19. Eur. J. Clin. Microbiol. Infect. Dis. 2021;40:1721–1726. doi: 10.1007/s10096-021-04202-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.RKI - Coronavirus SARS-CoV-2 - Wochenbericht vom 24.3.2022, (n.d.). https://www.rki.de/DE/Content/InfAZ/N/Neuartiges_Coronavirus/Situationsberichte/Wochenbericht/Wochenbericht_2022-03-24.html (accessed December 5, 2022).
  • 21.Hui K.P.Y., Ng K.C., Ho J.C.W., Yeung H.W., Ching R.H.H., Gu H., Chung J.C.K., Chow V.L.Y., Sit K.Y., Hsin M.K.Y., Au T.W.K., Poon L.L.M., Peiris M., Nicholls J.M., Chan M.C.W. Replication of SARS-CoV-2 Omicron BA.2 variant in ex vivo cultures of the human upper and lower respiratory tract. EBioMedicine. 2022:83. doi: 10.1016/j.ebiom.2022.104232. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

mmc1.docx (89.4KB, docx)

Articles from Journal of Clinical Virology are provided here courtesy of Elsevier

RESOURCES