Abstract
Cardiac output measured by thermodilution in 25 patients within 24 hours of acute myocardial infarction was compared with cardiac output measured by Doppler echocardiography (24 patients) and electrical bioimpedance (25 patients). The mean (range) cardiac outputs measured by Doppler (4.03 (2.2-6.0) 1/min) and electrical bioimpedance (3.79 (1.1-6.2) 1/min) were similar to the mean thermodilution value (3.95 (2.1-6.2) 1/min). Both non-invasive techniques agreed closely with thermodilution in most patients. None the less, three results with each method disagreed with thermodilution by more than 1 1/min. Both non-invasive techniques were reproducible and accurate in most patients with acute myocardial infarction. Doppler echocardiography was time consuming and technically demanding. Electrical bioimpedance was simple to use and had the additional advantage of allowing continuous monitoring of the cardiac output.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Appel P. L., Kram H. B., Mackabee J., Fleming A. W., Shoemaker W. C. Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med. 1986 Nov;14(11):933–935. doi: 10.1097/00003246-198611000-00004. [DOI] [PubMed] [Google Scholar]
- Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
- Bouchard A., Blumlein S., Schiller N. B., Schlitt S., Byrd B. F., 3rd, Ports T., Chatterjee K. Measurement of left ventricular stroke volume using continuous wave Doppler echocardiography of the ascending aorta and M-mode echocardiography of the aortic valve. J Am Coll Cardiol. 1987 Jan;9(1):75–83. doi: 10.1016/s0735-1097(87)80085-2. [DOI] [PubMed] [Google Scholar]
- CHAPMAN C. B., FISHER J. N., SPROULE B. J. Behavior of stroke volume at rest and during exercise in human beings. J Clin Invest. 1960 Aug;39:1208–1213. doi: 10.1172/JCI104136. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Diamond G. A. Correlation, causation and agreement. Am J Cardiol. 1989 Feb 1;63(5):392–392. doi: 10.1016/0002-9149(89)90366-4. [DOI] [PubMed] [Google Scholar]
- Forrester J. S., Diamond G., McHugh T. J., Swan H. J. Filling pressures in the right and left sides of the heart in acute myocardial infarction. A reappraisal of central-venous-pressure monitoring. N Engl J Med. 1971 Jul 22;285(4):190–193. doi: 10.1056/NEJM197107222850402. [DOI] [PubMed] [Google Scholar]
- George R. J., Winter R. J. The clinical value of measuring cardiac output. Br J Hosp Med. 1985 Aug;34(2):89–95. [PubMed] [Google Scholar]
- Gibson D. G. Stroke distance--an improved measure of cardiovascular function? Br Heart J. 1985 Feb;53(2):121–122. doi: 10.1136/hrt.53.2.121. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Haites N. E., McLennan F. M., Mowat D. H., Rawles J. M. Assessment of cardiac output by the Doppler ultrasound technique alone. Br Heart J. 1985 Feb;53(2):123–129. doi: 10.1136/hrt.53.2.123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ihlen H., Amlie J. P., Dale J., Forfang K., Nitter-Hauge S., Otterstad J. E., Simonsen S., Myhre E. Determination of cardiac output by Doppler echocardiography. Br Heart J. 1984 Jan;51(1):54–60. doi: 10.1136/hrt.51.1.54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ihlen H., Endresen K., Golf S., Nitter-Hauge S. Cardiac stroke volume during exercise measured by Doppler echocardiography: comparison with the thermodilution technique and evaluation of reproducibility. Br Heart J. 1987 Nov;58(5):455–459. doi: 10.1136/hrt.58.5.455. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Keim H. J., Wallace J. M., Thurston H., Case D. B., Drayer J. I., Laragh J. H. Impedance cardiography for determination of stroke index. J Appl Physiol. 1976 Nov;41(5 Pt 1):797–799. doi: 10.1152/jappl.1976.41.5.797. [DOI] [PubMed] [Google Scholar]
- Labovitz A. J., Buckingham T. A., Habermehl K., Nelson J., Kennedy H. L., Williams G. A. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output. Am Heart J. 1985 Feb;109(2):327–332. doi: 10.1016/0002-8703(85)90602-7. [DOI] [PubMed] [Google Scholar]
- Labovitz A. J., Buckingham T. A., Habermehl K., Nelson J., Kennedy H. L., Williams G. A. The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output. Am Heart J. 1985 Feb;109(2):327–332. doi: 10.1016/0002-8703(85)90602-7. [DOI] [PubMed] [Google Scholar]
- Lewis J. F., Kuo L. C., Nelson J. G., Limacher M. C., Quinones M. A. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation. 1984 Sep;70(3):425–431. doi: 10.1161/01.cir.70.3.425. [DOI] [PubMed] [Google Scholar]
- Mehta N., Bennett D. E. Impaired left ventricular function in acute myocardial infarction assessed by Doppler measurement of ascending aortic blood velocity and maximum acceleration. Am J Cardiol. 1986 May 1;57(13):1052–1058. doi: 10.1016/0002-9149(86)90673-9. [DOI] [PubMed] [Google Scholar]
- Mehta N., Iyawe V. I., Cummin A. R., Bayley S., Saunders K. B., Bennett E. D. Validation of a Doppler technique for beat-to-beat measurement of cardiac output. Clin Sci (Lond) 1985 Oct;69(4):377–382. doi: 10.1042/cs0690377. [DOI] [PubMed] [Google Scholar]
- Mehta N., Iyawe V. I., Cummin A. R., Bayley S., Saunders K. B., Bennett E. D. Validation of a Doppler technique for beat-to-beat measurement of cardiac output. Clin Sci (Lond) 1985 Oct;69(4):377–382. doi: 10.1042/cs0690377. [DOI] [PubMed] [Google Scholar]
- Nicolosi G. L., Pungercic E., Cervesato E., Pavan D., Modena L., Moro E., Dall'Aglio V., Zanuttini D. Feasibility and variability of six methods for the echocardiographic and Doppler determination of cardiac output. Br Heart J. 1988 Mar;59(3):299–303. doi: 10.1136/hrt.59.3.299. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shoemaker W. C., Appel P. L., Kram H. B., Nathan R. C., Thompson J. L. Multicomponent noninvasive physiologic monitoring of circulatory function. Crit Care Med. 1988 May;16(5):482–490. doi: 10.1097/00003246-198805000-00004. [DOI] [PubMed] [Google Scholar]
- Smith S. A., Russell A. E., West M. J., Chalmers J. Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques. Br Heart J. 1988 Mar;59(3):292–298. doi: 10.1136/hrt.59.3.292. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Smith S. A. The author reply. Br Heart J. 1989 Jan;61(1):129–129. doi: 10.1136/hrt.61.1.129. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang Y., Nitter-Hauge S., Ihlen H., Myhre E. Doppler echocardiographic measurement of cardiac output using the mitral orifice method. Br Heart J. 1985 Feb;53(2):130–136. doi: 10.1136/hrt.53.2.130. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang Y., Nitter-Hauge S., Ihlen H., Myhre E. Doppler echocardiographic measurement of cardiac output using the mitral orifice method. Br Heart J. 1985 Feb;53(2):130–136. doi: 10.1136/hrt.53.2.130. [DOI] [PMC free article] [PubMed] [Google Scholar]