Abstract
OBJECTIVE--To measure the noise produced and related subjective complaints after implantation of four different mechanical heart valve prostheses and to identify further factors related to the patient and prosthesis that influence noise generation and complaints. DESIGN--Sound pressure was measured 5 and 10 cm and 1 m from the point of maximal impulse on the body surface by a calibrated meter in quiet rooms with either a decibel(A) filter or octave filters. The patients were asked about their complaints and examined physically. SETTING--The measurements were conducted in silent rooms of ear, nose, and throat departments. The patients had been operated on either in a university hospital or a community hospital. MAIN OUTCOME MEASURES--Sound pressures of frequency bands and sound pressures measured in dB(A) at various distances. Complaints registerd were: sleep disturbance, disturbance during daytime, "wants a less noisy prosthesis," and "can hear the closing click". PATIENTS--143 patients after heart valve replacement with St Jude Medical (n = 35), Duromedics Edwards (n = 38), Carbomedics (n = 34) and Björk-Shiley Monostrut (n = 36) prostheses operated on between 1984 and 1988 were matched for valve position, ring size, and body surface area. RESULTS--Duromedics Edwards (33.5 (6) dB(A)) and Björk-Shiley Monostrut valves (31 (4) dB(A)) were significantly louder than St Jude Medical (24 (4) dB(A)) and Carbomedics (25 (6) dB(A)) prostheses (p = 0.0001) (mean (SD)). The louder valves were significantly more often heard by the patients (p = 0.0012) and caused more complaints both during sleep (p = 0.024) and during the daytime (p = 0.07). Patients with these valves were more likely to want a less noisy valve (p = 0.0047). Patients with symptoms were younger, had better hearing, and were more likely to be in sinus rhythm. As well as the type of prostheses, the valve diameter and body height also had an effect on sound emission. CONCLUSIONS--The intensity of the closing click of mechanical valve prostheses was significantly different for various designs. Patient complaints were related to the objectively measured sound pressure. Noise production should be considered when a mechanical valve is selected.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Arom K. V., Nicoloff D. M., Kersten T. E., Northrup W. F., 3rd, Lindsay W. G., Emery R. W. Ten years' experience with the St. Jude Medical valve prosthesis. Ann Thorac Surg. 1989 Jun;47(6):831–837. doi: 10.1016/0003-4975(89)90014-3. [DOI] [PubMed] [Google Scholar]
- Gordon R. F., Najmi M., Kingsley B., Segal B. L., Linhart J. W. Spectroanalytic evaluation of aortic prosthetic valves. Chest. 1974 Jul;66(1):44–49. doi: 10.1378/chest.66.1.44. [DOI] [PubMed] [Google Scholar]
- Klepetko W., Moritz A., Mlczoch J., Schurawitzki H., Domanig E., Wolner E. Leaflet fracture in Edwards-Duromedics bileaflet valves. J Thorac Cardiovasc Surg. 1989 Jan;97(1):90–94. [PubMed] [Google Scholar]
- Köymen H., Altay B. K., Ider Y. Z. A study of prosthetic heart valve sounds. IEEE Trans Biomed Eng. 1987 Nov;34(11):853–863. doi: 10.1109/tbme.1987.326006. [DOI] [PubMed] [Google Scholar]
- Lindblom D., Rodriguez L., Björk V. O. Mechanical failure of the Björk-Shiley valve. Updated follow-up and considerations on prophylactic rereplacement. J Thorac Cardiovasc Surg. 1989 Jan;97(1):95–97. [PubMed] [Google Scholar]
- Meno F., Reddy P. S., Bernardi L. Heart sound propagation in the human thorax. Clin Phys Physiol Meas. 1985 May;6(2):123–129. doi: 10.1088/0143-0815/6/2/003. [DOI] [PubMed] [Google Scholar]
- Moritz A., Klepetko W., Khünl-Brady G., Schreiner W., Pabinger I., Bailer H., Lang I., Wolner E. Four year follow-up of the Duromedics Edwards bileaflet valve prostheses. J Cardiovasc Surg (Torino) 1990 May-Jun;31(3):274–282. [PubMed] [Google Scholar]
- Schöndube F., Keusen H., Messmer B. J. Physical analysis of the Björk-Shiley prosthetic valve sound. J Thorac Cardiovasc Surg. 1983 Jul;86(1):136–141. [PubMed] [Google Scholar]
- Thulin L. I., Bain W. H., Huysmans H. H., van Ingen G., Prieto I., Basile F., Lindblom D. A., Olin C. L. Heart valve replacement with the Björk-Shiley Monostrut valve: early results of a multicenter clinical investigation. Ann Thorac Surg. 1988 Feb;45(2):164–170. doi: 10.1016/s0003-4975(10)62430-7. [DOI] [PubMed] [Google Scholar]
- Thulin L. I., Reul H., Giersiepen M., Olin C. L. An in vitro study of prosthetic heart valve sound. Scand J Thorac Cardiovasc Surg. 1989;23(1):33–37. doi: 10.3109/14017438909105964. [DOI] [PubMed] [Google Scholar]