Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1993 Jan;69(1):83–92. doi: 10.1136/hrt.69.1.83

Implications for present and future applications of the implantable cardioverter-defibrillator resulting from the use of a simple model of cost efficacy.

M H Anderson 1, A J Camm 1
PMCID: PMC1024924  PMID: 8457402

Abstract

OBJECTIVE--To develop a model to assess the cost-efficacy of the implantable cardioverter defibrillator to prevent sudden death. The model must be sufficiently flexible to allow the use of cost and survival figures derived from different sources. SETTING--The study was conducted in a teaching hospital department of cardiology with experience of 40 implantable cardioverter defibrillator implants and a large database of over 500 survivors of myocardial infarction. PROCEDURE--The basic costs of screening tests, stay in hospital, and purchase of implantable cardioverter defibrillators were derived from St George's Hospital during 1991. To assess the cost-efficacy of various strategies for the use of implantable cardioverter defibrillators, survival data taken from published studies or from our own database. Implications of the national cost of the various strategies were calculated by estimating the number of patients a year requiring implantation of a defibrillator if the strategy was adopted. RESULTS--Use of implantable cardioverter defibrillators in survivors of cardiac arrest costs between 22,400 pounds and 57,000 pounds for each year of life saved. Most of the strategies proposed by the current generation of implantable cardioverter defibrillator trials have cost efficacies in the same range, and adoption of any one of these strategies in the United Kingdom could cost between 2 million pounds and 100 million pounds a year. Future technical and medical developments mean that cost-efficacy may be improved by up to 80%. Due to the limitations of screening tests currently available restriction on the use of implantable cardioverter defibrillators to those groups where it seems highly cost-effective will result in a small impact on overall mortality from sudden cardiac death. CONCLUSION--Present and possible future applications of the implantable cardioverter defibrillator seem expensive when compared with currently accepted treatments. Technical and medical developments are, however, likely to result in a dramatic improvement in cost efficacy over the next few years.

Full text

PDF
83

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bigger J. T., Jr Future studies with the implantable cardioverter defibrillator. Pacing Clin Electrophysiol. 1991 May;14(5 Pt 2):883–889. doi: 10.1111/j.1540-8159.1991.tb04129.x. [DOI] [PubMed] [Google Scholar]
  2. Bigger J. T., Jr Prophylactic use of implantable cardioverter defibrillators: medical, technical, economic considerations. Pacing Clin Electrophysiol. 1991 Feb;14(2 Pt 2):376–380. doi: 10.1111/j.1540-8159.1991.tb05125.x. [DOI] [PubMed] [Google Scholar]
  3. Campbell R. W. Life at a price: the implantable defibrillator. Br Heart J. 1990 Sep;64(3):171–173. doi: 10.1136/hrt.64.3.171. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Cobbe S. M., Redmond M. J., Watson J. M., Hollingworth J., Carrington D. J. "Heartstart Scotland"--initial experience of a national scheme for out of hospital defibrillation. BMJ. 1991 Jun 22;302(6791):1517–1520. doi: 10.1136/bmj.302.6791.1517. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Denniss A. R., Richards D. A., Cody D. V., Russell P. A., Young A. A., Cooper M. J., Ross D. L., Uther J. B. Prognostic significance of ventricular tachycardia and fibrillation induced at programmed stimulation and delayed potentials detected on the signal-averaged electrocardiograms of survivors of acute myocardial infarction. Circulation. 1986 Oct;74(4):731–745. doi: 10.1161/01.cir.74.4.731. [DOI] [PubMed] [Google Scholar]
  6. Fogoros R. N., Fiedler S. B., Elson J. J. The automatic implantable cardioverter-defibrillator in drug-refractory ventricular tachyarrhythmias. Ann Intern Med. 1987 Nov;107(5):635–641. doi: 10.7326/0003-4819-107-5-635. [DOI] [PubMed] [Google Scholar]
  7. Francis G. S. Should asymptomatic ventricular arrhythmias in patients with congestive heart failure be treated with antiarrhythmic drugs? J Am Coll Cardiol. 1988 Jul;12(1):274–283. doi: 10.1016/0735-1097(88)90388-9. [DOI] [PubMed] [Google Scholar]
  8. Gomes J. A., Winters S. L., Stewart D., Horowitz S., Milner M., Barreca P. A new noninvasive index to predict sustained ventricular tachycardia and sudden death in the first year after myocardial infarction: based on signal-averaged electrocardiogram, radionuclide ejection fraction and Holter monitoring. J Am Coll Cardiol. 1987 Aug;10(2):349–357. doi: 10.1016/s0735-1097(87)80018-9. [DOI] [PubMed] [Google Scholar]
  9. Gross J., Zilo P., Ferrick K., Fisher J. D., Furman S. Sudden death mortality in implantable cardioverter defibrillator patients. Pacing Clin Electrophysiol. 1991 Feb;14(2 Pt 2):250–254. doi: 10.1111/j.1540-8159.1991.tb05102.x. [DOI] [PubMed] [Google Scholar]
  10. Herre J. M., Sauve M. J., Malone P., Griffin J. C., Helmy I., Langberg J. J., Goldberg H., Scheinman M. M. Long-term results of amiodarone therapy in patients with recurrent sustained ventricular tachycardia or ventricular fibrillation. J Am Coll Cardiol. 1989 Feb;13(2):442–449. doi: 10.1016/0735-1097(89)90525-1. [DOI] [PubMed] [Google Scholar]
  11. Kalbfleisch K. R., Lehmann M. H., Steinman R. T., Jackson K., Axtell K., Schuger C. D., Tchou P. J. Reemployment following implantation of the automatic cardioverter defibrillator. Am J Cardiol. 1989 Jul 15;64(3):199–202. doi: 10.1016/0002-9149(89)90457-8. [DOI] [PubMed] [Google Scholar]
  12. Keren R., Aarons D., Veltri E. P. Anxiety and depression in patients with life-threatening ventricular arrhythmias: impact of the implantable cardioverter-defibrillator. Pacing Clin Electrophysiol. 1991 Feb;14(2 Pt 1):181–187. doi: 10.1111/j.1540-8159.1991.tb05088.x. [DOI] [PubMed] [Google Scholar]
  13. Kuppermann M., Luce B. R., McGovern B., Podrid P. J., Bigger J. T., Jr, Ruskin J. N. An analysis of the cost effectiveness of the implantable defibrillator. Circulation. 1990 Jan;81(1):91–100. doi: 10.1161/01.cir.81.1.91. [DOI] [PubMed] [Google Scholar]
  14. Larsen G. C., Manolis A. S., Sonnenberg F. A., Beshansky J. R., Estes N. A., Pauker S. G. Cost-effectiveness of the implantable cardioverter-defibrillator: effect of improved battery life and comparison with amiodarone therapy. J Am Coll Cardiol. 1992 May;19(6):1323–1334. doi: 10.1016/0735-1097(92)90341-j. [DOI] [PubMed] [Google Scholar]
  15. Mirowski M., Reid P. R., Mower M. M., Watkins L., Gott V. L., Schauble J. F., Langer A., Heilman M. S., Kolenik S. A., Fischell R. E. Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med. 1980 Aug 7;303(6):322–324. doi: 10.1056/NEJM198008073030607. [DOI] [PubMed] [Google Scholar]
  16. Nisam S., Mower M., Moser S. ICD clinical update: first decade, initial 10,000 patients. Pacing Clin Electrophysiol. 1991 Feb;14(2 Pt 2):255–262. doi: 10.1111/j.1540-8159.1991.tb05103.x. [DOI] [PubMed] [Google Scholar]
  17. Nisam S., Mower M., Moser S. ICD clinical update: first decade, initial 10,000 patients. Pacing Clin Electrophysiol. 1991 Feb;14(2 Pt 2):255–262. doi: 10.1111/j.1540-8159.1991.tb05103.x. [DOI] [PubMed] [Google Scholar]
  18. Nisam S., Thomas A., Mower M., Hauser R. Identifying patients for prophylactic automatic implantable cardioverter defibrillator therapy: status of prospective studies. Am Heart J. 1991 Aug;122(2):607–612. doi: 10.1016/0002-8703(91)91032-i. [DOI] [PubMed] [Google Scholar]
  19. O'Brien B. J., Buxton M. J., Ferguson B. A. Measuring the effectiveness of heart transplant programmes: quality of life data and their relationship to survival analysis. J Chronic Dis. 1987;40 (Suppl 1):137S–158S. doi: 10.1016/s0021-9681(87)80043-7. [DOI] [PubMed] [Google Scholar]
  20. O'Donoghue S., Platia E. V., Brooks-Robinson S., Mispireta L. Automatic implantable cardioverter-defibrillator: is early implantation cost-effective? J Am Coll Cardiol. 1990 Nov;16(5):1258–1263. doi: 10.1016/0735-1097(90)90563-5. [DOI] [PubMed] [Google Scholar]
  21. Packer M. Sudden unexpected death in patients with congestive heart failure: a second frontier. Circulation. 1985 Oct;72(4):681–685. doi: 10.1161/01.cir.72.4.681. [DOI] [PubMed] [Google Scholar]
  22. Pedoe H. T., Clayton D., Morris J. N., Brigden W., McDonald L. Coronary heart-attacks in East London. Lancet. 1975 Nov 1;2(7940):833–838. doi: 10.1016/s0140-6736(75)90233-0. [DOI] [PubMed] [Google Scholar]
  23. Richards D. A., Byth K., Ross D. L., Uther J. B. What is the best predictor of spontaneous ventricular tachycardia and sudden death after myocardial infarction? Circulation. 1991 Mar;83(3):756–763. doi: 10.1161/01.cir.83.3.756. [DOI] [PubMed] [Google Scholar]
  24. Stevenson L. W., Fowler M. B., Schroeder J. S., Stevenson W. G., Dracup K. A., Fond V. Poor survival of patients with idiopathic cardiomyopathy considered too well for transplantation. Am J Med. 1987 Nov;83(5):871–876. doi: 10.1016/0002-9343(87)90644-9. [DOI] [PubMed] [Google Scholar]
  25. Stults K. R., Brown D. D., Schug V. L., Bean J. A. Prehospital defibrillation performed by emergency medical technicians in rural communities. N Engl J Med. 1984 Jan 26;310(4):219–223. doi: 10.1056/NEJM198401263100403. [DOI] [PubMed] [Google Scholar]
  26. Vlay S. C., Olson L. C., Fricchione G. L., Friedman R. Anxiety and anger in patients with ventricular tachyarrhythmias. Responses after automatic internal cardioverter defibrillator implantation. Pacing Clin Electrophysiol. 1989 Feb;12(2):366–373. doi: 10.1111/j.1540-8159.1989.tb02670.x. [DOI] [PubMed] [Google Scholar]
  27. Weaver W. D., Cobb L. A., Hallstrom A. P., Fahrenbruch C., Copass M. K., Ray R. Factors influencing survival after out-of-hospital cardiac arrest. J Am Coll Cardiol. 1986 Apr;7(4):752–757. doi: 10.1016/s0735-1097(86)80332-1. [DOI] [PubMed] [Google Scholar]
  28. Wever E. F., Hauer R. N. Cost-effectiveness considerations: the Dutch prospective study of the automatic implantable cardioverter defibrillator as first-choice therapy. Pacing Clin Electrophysiol. 1992 Apr;15(4 Pt 3):690–693. doi: 10.1111/j.1540-8159.1992.tb05164.x. [DOI] [PubMed] [Google Scholar]
  29. Wilber D. J., Garan H., Finkelstein D., Kelly E., Newell J., McGovern B., Ruskin J. N. Out-of-hospital cardiac arrest. Use of electrophysiologic testing in the prediction of long-term outcome. N Engl J Med. 1988 Jan 7;318(1):19–24. doi: 10.1056/NEJM198801073180105. [DOI] [PubMed] [Google Scholar]
  30. Wilber D. J., Olshansky B., Moran J. F., Scanlon P. J. Electrophysiological testing and nonsustained ventricular tachycardia. Use and limitations in patients with coronary artery disease and impaired ventricular function. Circulation. 1990 Aug;82(2):350–358. doi: 10.1161/01.cir.82.2.350. [DOI] [PubMed] [Google Scholar]
  31. Williams A. Economics of coronary artery bypass grafting. Br Med J (Clin Res Ed) 1985 Aug 3;291(6491):326–329. doi: 10.1136/bmj.291.6491.326. [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Winkle R. A., Mead R. H., Ruder M. A., Gaudiani V. A., Smith N. A., Buch W. S., Schmidt P., Shipman T. Long-term outcome with the automatic implantable cardioverter-defibrillator. J Am Coll Cardiol. 1989 May;13(6):1353–1361. doi: 10.1016/0735-1097(89)90310-0. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES