Abstract
The arterial occlusive disease is one of the leading causes of cardiovascular diseases, often requiring revascularization. Lack of suitable small-diameter vascular grafts (SDVGs), infection, thrombosis, and intimal hyperplasia associated with synthetic vascular grafts lead to a low success rate of SDVGs (< 6 mm) transplantation in the clinical treatment of cardiovascular diseases. The development of fabrication technology along with vascular tissue engineering and regenerative medicine technology allows biological tissue-engineered vascular grafts to become living grafts, which can integrate, remodel, and repair the host vessels as well as respond to the surrounding mechanical and biochemical stimuli. Hence, they potentially alleviate the shortage of existing vascular grafts. This paper evaluates the current advanced fabrication technologies for SDVGs, including electrospinning, molding, 3D printing, decellularization, and so on. Various characteristics of synthetic polymers and surface modification methods are also introduced. In addition, it also provides interdisciplinary insights into the future of small-diameter prostheses and discusses vital factors and perspectives for developing such prostheses in clinical applications. We propose that the performance of SDVGs can be improved by integrating various technologies in the near future.
Graphical Abstract
Keywords: Small-diameter vascular grafts, Surface modification, Cardiovascular diseases, Biomimetics, Tissue engineering
Highlights
• The commonly used synthetic polymers for vascular grafts are reviewed.
• Various methods for surface modification of artificial vascular grafts are summarized.
• Latest fabrication techniques for small-diameter vascular grafts and their mechanical and biological properties are systematically summarized.
• Current state and future perspective of small-diameter vascular grafts are suggested.
Introduction
Cardiovascular diseases have one of the highest morbidities and mortality rates in the world, with an estimated 12.1 million to 18.6 million deaths in the past 30 years [1]. The most common cardiovascular diseases include coronary artery diseases, deep vein thrombosis, and myocardial infarction, usually associated with stenosis and embolism of blood vessels [2–4]. Bypass of grafting using autologous blood vessels, allogenic blood vessels, or artificial blood vessels is one of the most preferred treatments for cardiovascular diseases. The most optimal treatment among them is autologous blood vessels due to their adequate size and good biocompatibility for long-term patency. However, insufficient supply and trauma of the donor site limit its clinical application. In addition, the grafts of allogenic blood vessels are associated with potent immune responses, leading to the rejection of a graft. Therefore, artificial blood vessels might potentially replace or bypass diseased blood vessels. It is convenient to prepare an artificial vascular graft with a suitable diameter and length. The ideal vascular grafts should meet the following requirements: biocompatibility, mechanical properties, permeability, and anti-thrombosis [5, 6]. A vascular graft should be histo-compatible to resist immune responses and rejection. It must also have satisfactory mechanical properties to retain its integrity and to withstand physiological pressures. Furthermore, the microstructure should be conducive to nutrient exchange, elimination of metabolic products, and cell growth, allowing endothelial cells to attach, proliferate, and form a endothelial layer with tight junction, capable of resisting thrombosis. Nowadays, artificial vascular grafts for larger size diameters (> 6 mm) are used in the global vascular grafts market. In contrast, there is still no successful clinical trial for SDVGs (< 6 mm) which are in great demand for the treatment of various arterial complications such as coronary artery disease and pediatric congenital cardiovascular defects. The main reason is the intimal hyperplasia at the anastomotic site caused by compliance mismatch between SDVGs and native vessels as well as thrombus formation on the synthetic surface of SDVGs, resulting in low patency after implantation [7–9]. To overcome these limitations, various innovative approaches, including ideas such as their structures, surface modifications, and mechanical and biological requirements, are being adopted to mimic native vessels for the long-term patency of SDVGs [10–12]. Native blood vessels have a complex structure with three distinct layers, the inner layer (tunica intima), the middle layer (tunica media), and the outer layer (tunica adventitia), which significantly affects the mechanical and biological properties (Fig. 1) [13]. The inner layer, known as the endothelium, is the thinnest in the structures of a blood vessel, which acts as a barrier controlling the passage of biologically active substances and selectively penetrates fluids, ions, molecules, and leukocytes. The middle layer is relatively thick, mainly determined by the number of smooth muscle layers supported by elastic connective tissues. The smooth muscles and elastic fibers regulate the contraction and dilation of blood vessels. Meanwhile, a framework of collagen fibers in the middle layer binds the layers to the inner and outer layers of blood vessels and maintains the tension of blood vessels. The outer layer is generally thinner than the middle layer, primarily consisting of connective tissues with elastic and collagen fibers. It plays a vital role in supplying the vessel wall with nerves and self-vessels and helping to hold the vessels to surrounding tissues. Overall, to mimic native blood vessels, vascular graft constructs must be able to efficiently and selectively exchange nutrients and waste with all cells and meet mechanical requirements.
Furthermore, bioactive substances are introduced into the constructs for excellent biocompatibility and inducible endothelialization. Generally, the synthetic polymers that have been used as artificial vascular grafts lack bioactivity, and it is challenging to realize rapid endothelialization due to the low initial adhesion of endothelial cells. Therefore, the improvement of bioactivity in vascular grafts during fabrication is one of the most challenging subjects. Current approaches to this include the local delivery of angiogenic growth factors (vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), hepatocyte growth factor (HGF)) [14–16], the transplantation of stem and progenitor cells as well as angiogenic genes [17–19], and so on. Despite the success of these strategies in promoting endothelial cell adhesion to reduce thrombosis and intimal hyperplasia, there are still some drawbacks.
This review appraises a comprehensive overview of the materials with surface modification and fabrication technologies for SDVGs. First, we briefly introduce the synthetic polymers used for vascular grafts and their surface modification combined with their structures. We further describe the latest techniques and strategies for the fabrication of SDVGs (Fig. 1). Finally, the current status of the related researches and future perspectives will be addressed.
Materials and their surface modification for SDVGs
In general, both natural polymers and synthetic polymers are used for vascular grafts. Natural polymers, such as collagen, elastin, gelatin, and lecithin, comprised of the components of the extracellular matrix (ECM), provide many necessary signals for cell functions. They, therefore, have adequate biocompatibility and are likely to be less rejected by the immune system. However, their low mechanical properties and rapid degradation limit their individual use for vascular grafts. Therefore, these natural polymers are usually mixed with synthetic polymers to mimic native blood vessels that, give rise to better cell attachment and proliferation contributed by natural polymers, and meet mechanical requirements for native blood vessels owing to good mechanical properties of synthetic polymers [20–22]. It is reported that blending proper ratios of collagen, elastin, and synthetic polymers improves tensile strength and Young’s modulus and exhibits a good biocompatibility [23]. Herein, we introduce several commonly used synthetic polymers as materials for vascular grafts.
Commonly used synthetic polymers for vascular grafts
Considering the commercialization of large-diameter synthetic vascular grafts with more than 90% patency after one-year implantation [24], researchers have focused on available synthetic polymers used for SDVGs. The most commonly used synthetic polymers for vascular grafts are expanded polytetrafluoroethylene (ePTFE), polyethylene terephthalate (PET), polyurethane (PU), polylactic acid (PLA), poly(-caprolactone) (PCL), poly (glycolic acid) (PGA), and some hybrid polymers. An overview of these synthetic polymers and their properties for vascular grafts are compared with rat aorta and listed in Table 1 [25–33].
Table 1.
Graft materials | Molecular weight | Polymer solution concentration | Inner Diameter (mm) |
Burst pressure (mmHg) | Ref |
---|---|---|---|---|---|
Rat aorta | - | - | - | 1043 ± 326 | [30] |
Human arteries | - | - | - | 2031 ~ 4225 | [27] |
ePTFE | - | - | 1.0 | 2715 ± 33 | [28] |
PET (Dacron®) | - | - | - | 4145 ± 207 | [26] |
Nonwoven PET | - | - | 4.7 | 1509 ± 175 | |
PU | - | 15 wt% in THF/DMF (3:1 v/v) | 2.0 | 1156 ± 149 | [29] |
PU/PCL | 1:1 ratio | 10 wt% in chloroform/ethanol (7:3); 15 wt% in THF/DMF (3:1 v/v) | 2.0 | 2017 ± 72 | |
PCL | 80 kDa | 15% in CHCl3/EtOH (70% v/v) | 2.0 | 3280 ± 280 | [32] |
PLLA/PCL | 130 kDa | 6% in 2, 2, 2-trifluoroethanol | 1.0 | 3175 ± 438 | [25] |
PET/PU | 4:1 ratio | 18 wt% in HFIP | 4.0 | 1787.64 ± 76.61 | [33] |
Chloroform (CHCl3); ethanol (EtOH); N,N-dimethylformamide (DMF); tetrahydrofuran (THF); 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP)
Expanded polytetrafluoroethylene (ePTFE)
Expanded polytetrafluoroethylene (ePTFE) is obtained by structurally modifying PTFE to maintain its good chemical stability. The ePTFE-based large-diameter vascular grafts emerged in 1974 with desirable mechanical strength, excellent resistance to degradation, and satisfactory patency (Fig. 2C (i)), leading to ePTFE (Gore-Tex®) being commercially used as large diameter (> 6 mm) vascular grafts [24]. However, it prevents endothelial cell adhesion and leads to platelet activation due to the hydrophobic surface, resulting in thrombosis, poor patency, and low compliance for SDVGs [34]. Therefore, recent studies focus on modifying the surface of ePTFE to prohibit thrombosis, restenosis, and rapid endothelialization (Fig. 2A, B). For example, ePTFE surfaces are modified by functional biomolecules, plasma treatment, the immobilization of proteins (collagen and elastin), or binding of anticoagulants (heparin), and so on [35–41]. These modifications successfully promote endothelialization and prevent platelet adhesion and thrombosis, providing the basis for the further clinical application of SDVGs (Fig. 2C (ii-iii)).
Polyethylene terephthalate (PET)
Polyethylene terephthalate (PET, Dacron®), with high elastic modulus, mechanical stability, and excellent tensile strength, is one of commercially used synthetic polymers for large-diameter vascular grafts. Generally, PET is divided into woven fibers (Dacron®) and nonwoven PET, of which the former is less porous than the latter, directly affecting mechanical and biological properties (Table 1). The Dacron has been used for large diameter vascular grafts for 60 years as it has the higher patency than 85% at five years [42, 43]. Although it has excellent mechanical properties and high patency for large-diameter vascular grafts, some limitations exist if it is used for tiny-diameter vascular grafts. For example, the hydrophobic surface of PET, like that of ePTFE, resists endothelial cell adhesion and cell proliferation, causing platelet activation and thrombosis [44]. Therefore, similar approaches to the surface modification of ePTFE (such as plasma treatment, binding anticoagulants, or bioactive proteins) have been taken for the PET-based vascular grafts to decrease their surface hydrophobicity and enhance the cell adhesion and growth, achieving antithrombosis and rapid endothelialization.
Polyurethane (PU)
Polyurethane (PU) has a linear block structure composed of a soft segment (polyether or polyester polyol) and a hard segment (chain extender and diisocyanate) that alternately connects to the main chain with carbamate groups. The microphase separation structure of PU is obtained by the difference in the polarity of soft segments (low polarity) and hard segments (high polarity), facilitating superior biocompatibility, compliance, elasticity, and anticoagulation of PU compared with ePTFE and Dacron. The mechanical properties of the PU-based vascular grafts are comparable with native blood vessels, and the endothelialization rate of PU is faster than that of ePTFE and Dacron. In addition, the layer composed of new cells is thinner, facilitating better patency. However, its clinical application is limited by poor biostability and spontaneous degradation at the early implantation stage. Researchers have developed new generation of PU grafts using soft polycarbonate segments to improve their biostability in vivo, showing no degradation of polycarbonate PU during the early six months and faster endothelialization compared with ePTFE grafts. Despite improvements in mechanical and biological properties of PU through surface modifications (grafting functional groups or binding anticoagulants) and combined the structures with bioactive factors, the patency rate was less than 60% after 12 months, which is not enough to satisfy the clinical requirements [45]. Therefore, more advanced methods must be explored to form more reliable methods for SDVGs.
Poly(ɛ-caprolactone) (PCL)
Poly(ɛ-caprolactone) (PCL) consists of repeating units with one polar ester group and five non-polar methylene groups, and has excellent biodegradability and biocompatibility. The ester group in the PCL is broken down into water and carbon dioxide, forming less acid decomposition products, and it exhibits relatively slow degradation (more than two years) compared to other synthetic biodegradable polymers, providing sufficient time for cell adhesion, cellular ingrowth, and tissue regeneration [46]. However, the long-term patency for SDVG is still a challenge. Studies on modifying PCL vascular grafts to improve their mechanical properties, biocompatibility, and patency has been in progress. Chen et al. [47] showed that bioinspired zwitterionic poly[2-(methacryloyloxy)ethyl choline phosphate] treated PCL significantly reduced nonspecific protein adsorption and remarkably improved the adhesion and proliferation of the cells. Cuenca et al. [48] fabricated PCL SDVGs comprised of decellularized extracellular matrix with high mechanical properties, showing less hemolysis and low blood coagulation behavior than non-treated PCL. Though PCL vascular grafts exhibited complete endothelialization by 12 weeks and retained good patency without aneurysmal dilation or thrombosis until 18 months in the abdominal aorta of a rat model, a regression in cellular infiltration is observed, followed by calcification lesions after 18 months [32]. Therefore, it needs further investigations to be established as a long-term patent PCL vascular graft.
Polylactic acid (PLA)
Polylactic acid (PLA) is an aliphatic polyester derived from renewable resources with two optical isomers, poly-D-lactic acid (PDLA) and poly-L-lactic acid (PLLA), where PLLA is more commonly used in the medical materials [49]. It is reported that PLA deposition product is non-toxic and easily degraded into carbon dioxide and water without triggering an immune response in the body. Hence, it is considered an ideal material for biodegradable vascular grafts. Khalifehzadeh et al. [50] modified the surface of PLA with a perfluoro compound facilitated by surface activation by radio frequency plasma to reduce thrombogenicity and platelet reactivity. However, the cell affinity of PLA is relatively poor, making it challenging to adhere, proliferate and differentiate endothelial cells onto the surface of the vascular grafts. However, the weak mechanical properties of PLA and the rapid degradation rate (two months) limit its vascular application. This led to the researchers developing PLA composites compounded with other polymers, including natural or synthetic polymers, to enhance their mechanical properties and control their degradation rate [51, 52]. In addition, complete endothelialization before degradation requires improved in vitro bioactivity before implantation.
Types of surface modifications
Native blood vessels of the human body are composed of three layers mentioned before, each has different functions. Therefore, only using the original synthetic polymer materials could not satisfy the parts of blood vessels. Studies on modifications to the luminal surface and the introduction of biologically active substances for SDVGs are in the spotlight to mimic the multiple performance requirements for native blood vessels. Buscemi et al. [51] modified polycaprolactone (PCL) with alpha, beta-poly(N-2-hydroxyethyl)-D, and L-aspartamide, which blended with PLA and linked with heparin, showing excellent biocompatibility and moderate elastic tension to blood pressure in a pig model. Nguyen et al. [53] fabricated multilayer artificial blood vessels with PCL-gelatin as the inner layer, poly(lactic-co-glycolic acid)(PLGA)-gelatin as the middle layer, and PLGA-chitosan as an outer layer, which displayed excellent flexibility, cell attachment, and cell proliferation. The surface modification strategies expedited in situ endothelialization, eventually reducing thrombosis and intimal hyperplasia. Overall, surface modification of synthetic polymer vascular grafts can be divided into passive type modification (prevention of blood clot formation) and active type modification (dissolution of thrombus) according to the mechanism of antithrombosis (Fig. 3).
Passive type modification
Late endothelialization is a critical problem of SDVGs caused by the low initial adhesion of endothelial cells and the difficulty of in situ endothelialization. This problem needs immediate attention to be solved. To enhance endothelial cell adhesion and growth environment, many EC-adhesive ligands, including peptides (RGD, CAG, REDV, and YIGSR), vascular growth factors (VEGFs, FGFs, and HGFs), and antibodies, have been used in artificial vascular grafts. They have also been used in artificial vascular scaffolds, promoting endothelial cell adhesion and proliferation, thus reducing thrombosis and intimal hyperplasia, and improving its patency rate, providing an adhesion and growth environment for endothelial cells (Fig. 3A) [54, 56]. Ding et al. [57] modified a polyurethane surface with REDV peptide to enhance the endothelialization of implants. The process needs three days to form a layer of primary human umbilical vein endothelial cells (HUVECs) on the PU/REDV surfaces. In contrast, the proliferation of primary human umbilical artery smooth muscle cells (HUASMCs) was inhibited. Moreover, the PU/REDV surface reduced the activity of adhered platelets, selectively regulated HUVECs, and delayed the proliferation of human umbilical artery ECs (HUAECs).
Tissue-engineered vascular grafts would induce the body to recognize them as autologous, decreasing the risk of rejection [58]. This modification thus improves the anti-thrombosis of vascular grafts; however, it still needs further development for the long-term patency of SDVGs.
Active type modification
Extensive studies have been performed to elucidate different methods of surface modification and their role in antithrombosis. Yet limited attempts have been made to modulate thrombosis in the initial implantation stage. The lack of local tissue fibrinolytic activity, capable of dissolving intravascular thrombosis during the early stage of implantation, might be one of the attributes responsible for the failure of vascular graft implantation [59]. Subsequently, many groups have attempted to develop thrombin-sensing materials. Gunawan et al. [60] designed a thrombin-sensing fabric based on thrombin formation during blood coagulation. They developed bright poly(2-oxazoline) based multifunctional polymer that was degraded by serine protein thrombin and released the urokinase plasminogen activator to target the focal area of thrombosis to dissolve the thrombus selectively. Du et al. [55] also developed a thrombin-triggering thrombolytic material, which act when a clot or thrombus formation and effectively prevented thrombosis formed at the early stage (Fig. 3B). Lin’s group [61] developed a bio-responsive peptide-polysaccharide nano-complex which could self-titrate the release of anticoagulants depending on varying levels of coagulation activity through negative feedback regulator. The nano-complex circulates are active only under thrombotic conditions with releasing anticoagulant. The nano-complex locally releases its drug payload and prevents thrombosis in response to life-threatening pulmonary embolism.
Although the surface modification techniques of vascular graft materials have become highly advanced and have already been commercialized in the large diameter, their long-term patency effect in SDVGs is still not ideal. The problems of thrombosis and intimal hyperplasia have not been fully resolved, failing to establish a causative relationship.
Fabrication technologies
The problems of cell adhesion, proliferation, and nutrient transport warrant tissue-engineered vascular grafts to be porous, such as fiber diameter and pore size. There are many methods to fabricate porous vascular grafts, such as electrospinning [62–65], phase separation [66, 67], freeze-drying [68, 69], 3D printing [70, 71], and so on. The advantages and disadvantages of each fabrication technology have been listed in Table 2.
Table 2.
Scaffold Fabrication Method | Advantage | Disadvantage | Ref |
---|---|---|---|
Electrospinning |
– Mimic similar fibrous architecture of native extracellular matrix structure with high porosity to provide excellent biocompatibility including cell adhesion and proliferation – Increase mechanical properties – Fabricate multilayer grafts |
– Use toxic solvent and high voltage – Unable to fabricate complex structures – Coaxial electrospinning cause interface effects |
[72–77] |
Molding |
– Easy to setup – Fabricate multilayer grafts – Fabricate various geometries and dimensions with micropatterned surfaces – Control porosity and pore size by tuning the processing parameters |
– Use toxic solvent – Need for mechanical reinforcement |
[78–82] |
3D bioprinting |
– Automatic process with good controllability, reproducibility, and repeatability, including pore structures of vascular grafts – Incorporation of cells spatially |
– Limited materials – Slow to fabricate mass customization – Need for post-processing – Unable to fully mimic the complex structure and function of natural vasculature |
[83–85] |
Cell sheet engineering |
– Reduce immune response after implantation by using autologous cells – Biologically mimic native extracellular matrix |
– Unable to use readily due to production time – Potential for delamination failure |
[86–88] |
Decellularization |
– Preservation of the extracellular matrix – Favorable mechanical properties |
– Unable to use readily due to production time – Potential for immune responses – Difficulty in precise recellularization – High cost – Low cellularity upon implantation – Donor tissue loss if an autologous graft is used |
[89–92] |
Coculture of cells |
– Mimic the cellular environment in the body including cell–cell interactions and cell-culture interactions – Induce cell differentiation to improve the speed of vascularization |
– Difficulty in precise control over cell–cell interactions and separation for implantation | [93–95] |
Electrospinning
In the field of textile science, the technologies for the fabrication of vascular grafts include not only electrospinning but also knitting and weaving methods. Knitted vascular grafts have greater porosity than woven, encouraging infiltration of cells and capillary formation. This leads to better matching of the knitted vessels with the native ones and reduced intimal hyperplasia. However, large pore size, the swelling phenomenon of knitted vascular grafts, and the surgical difficulty of woven vascular grafts make it challenging to fabricate SDVGs. Among the available technologies, electrospinning is considered ideal for fabricating vascular grafts because the fiber fineness, thickness, three-dimensional structure, mechanical properties, and even degradation rate can be controlled by the adjustment of the parameters (Fig. 4A). Moreover, various types of polymers can be used for electrospinning. Different cross-sections of fibers (e.g., co-axial or tri-axial structure) are prepared by multiple needles and polymer solutions (Fig. 4B) [72, 96]. In the fiber morphology, continuous ultrafine fibers with diameters from 10 to 100 nm are fabricated by an electrospinning process, with large specific surface areas to benefit the mimicry of natural extracellular matrix (ECM) for cell adhesion, proliferation, and differentiation exhibiting excellent cell-compatibility. The luminal surface of appropriate vascular grafts is covered by newly formed endothelium similar to that of the native vessel with the regeneration of media and outer layer (Fig. 4C). In addition, bioactive factors are introduced to the vascular grafts and evenly distributed on the surface of the fibers, leading to widespread use in bone, nerve, and vascular graft repairs.
In general, the morphology and the properties of fibers are affected by various factors, such as molecular weight and cross-linking degree of polymers, the viscosity of the solution, solvent volatility, applied static voltage, receiving distance, temperature, humidity, and so on. Xiang et al. [99] used the electrospinning technique to fabricate a tubular scaffold composed of recombinant silk protein/PCL/gelatin with a 3 mm inner diameter, which showed high porosity leading to good cell growth and proliferation. Aydogdu et al. [100] prepared a novel biomimetic PCL/ethyl cellulose/collagen type-1 based SDVGs scaffold using the electrospinning method, which creates the most convenient synergy of a natural and synthetic polymer. This leads to the achievement of similarity to native small-diameter blood vessels with proper Young’s modulus and cell viability. In addition, Wang et al. [101] proposed a vascular graft by modifying its geometric structure. A spiral groove structure on a vascular graft was designed, a circular arc extending continuously on the inner wall. The transformation of the geometric system changed the blood flow distribution and increased the blood flow velocity near the border. Constant blood flow conditions lead to reduced deposition of harmful substances in the wall of the vascular grafts by creating a scouring force on the inner wall of the blood vessel. Moreover, increasing the shear force on the wall of the blood vessel leads to a long-term patency rate of the artificial blood vessel, especially the SDVGs (Fig. 4D). Furthermore, vascular grafts could be fabricated by combining one or two technologies; for example, fabrications can be achieved by a combination of electrospinning with the freeze-drying method, phase separation, molding method, or tissue engineering techniques [58, 72, 98, 102, 103]
Molding
Molding is also a traditional technology that generates tissue-engineered vascular grafts (Fig. 5A). It requires an easy set-up and allows the fabrication of customized shape (tubular-shape vascular grafts or complex branch vasculatures) scaffolds using polymers (Table 2) [104]. The polymer solution is poured into a designed mold with a fixed size of inner diameter and wall thickness of the vascular grafts (Fig. 5). A combination of technologies is required to generate suitable pores, such as gas foaming, phase separation, and among these methods, a thermal-induced phase separation is a common approach. Ma’s group [78] developed a SDVG using PLLA by the combination of molding and a thermally induced phase separation method, which allowed controlling the porosity and tubular size and was conducive to cell seeding and mass transfer for cell growth and function (Fig. 5B).
Moreover, it is demonstrated that varying processing parameters, such as the polymer concentration and temperature gradient, can control oriented microtubular structure. Zhen et al. [105] developed precision-engineered porous vascular grafts with crosslinked polyurethane which have excellent mechanical properties compared with native blood vessels. The results showed how pore size could significantly affect angiogenesis and cellularization, and polyurethanes with 40 μm pores have the highest level of angiogenesis and cellularization than that with 100 μm pores and non-porous structure, indicating the importance of pore size.
3D bioprinting
3D bioprinting is an emerging technology allowing the fabrication of irregular patient-specific tubular structure vascular grafts with high precision and reproducibility. It is suitable for printing tissue-specific cells, polymers, or cells-embedded polymers, mimicking the native-like tissue makeup (Fig. 6). According to the distinct principles, 3D bioprinting techniques can be divided into inkjet-based 3D bioprinting, extrusion-based 3D bioprinting, direct laser writing, and photocuring-based 3D bioprinting is one of the earliest technologies, which uses a piezoelectric or thermal actuator to separate the biological ink with cell-embedded polymers into a series of tiny droplets, forming a layer-by-layer 3D structure [83]. Moreover, inkjet-based 3D bioprinting could be designed with more than one nozzle to print different cells simultaneously at a high speed. However, the low driving pressure of the nozzle makes it challenging to use polymers with high viscosity, resulting in relatively low mechanical properties. Low-viscosity materials such as collagen and fibrin are suitable for inkjet-based 3D bioprinting with minimal cell death [106]. Compared with the inkjet-based method, extrusion-based 3D bioprinting technology is widely used for high-viscosity materials using a pneumatically or mechanically driven nozzle [84, 107] (Fig. 6A). Instead of individual droplets, continuous fibers are extruded from the nozzle which can be switched to monolayer or multilayers, leading to better structural strength for tissue-engineered vascular grafts (Fig. 6B). It is generally formed by ionic cross-linking, temperature-induced cross-linking, and light-induced cross-linking [84, 85]. In addition, laser direct writing 3D bioprinting is considered a non-nozzle inkjet type, which also uses droplets as the basic forming unit. This technology can accurately pattern multiple cell types, such as HUVECs, in two or three dimensions [108]. The advantage of this technology is that it avoids mechanical shear damage to the cells due to non-contact between biological inkjet and the device, in contrast to the damages that occur during the inkjet-based 3D bioprinting process. However, laser direct technology is still in its early days because of the cost, manufacturing time, lack of commercial printing devices, and so on. Photocuring-based 3D bioprinting is similar to the laser direct writing method, forming a 3D structure through multiple layers of biological inks selectively cross-linked by light. The advantage of this method involves the high precision of the structure regardless of the complexity; however, UV light and its initiators cause some damage to cells.
Cell sheet engineering
Cell sheet engineering technology develops complex and functional tissues through which the adhesion and detachment of cells can be controlled (Fig. 7A). A vascular bed with progressive stacking of three-layered cell sheets induces capillary networks containing microchannels or vascular framework within high cell density, which contributes to the anastomosis with host blood vessels (Fig. 7B) [86, 109]. Ahn et al. [110] developed a vascular scaffold with a smooth muscle cell sheet combined with electrospinning technology, mimicking the structural and biomechanical properties of native blood vessels. This provides high cell seeding efficiency, a more mature soft muscle layer, and good mechanical properties. If two tri-layered cell sheets are transplanted at intervals of 1 or 2 days, they will beat at the early stage followed by synchronized after one week, indicating their electrical connection (Fig. 7C) [111].
Decellularization
Vessel decellularization reduces the immune response of a scaffold after transplantation. Some products, such as Artegraft®, ProCol®, and SynerGraft®, are available for clinical use in relatively large diameter vascular grafts (Fig. 8A) [3]. Various decellularized protocols have been extensively investigated for applications to SDVGs. Massaro et al. [112] proposed a new and fast decellularization protocol for porcine carotid arteries with well-preserved ECM components and good mechanical properties comparable to that of the native blood vessels, which has an excellent potential for vascular grafts transplantation (Fig. 8B). Recently, decellularized vascular grafts from human small arteries/veins were developed using detergent-enzymatic decellularization protocols. This method maintains proper functioning without thrombosis or inflammatory rejection, as well as substantial endothelialization and cell invasion after implantation [113]. In addition, cross-linking agents can be used in decellularized arteries to improve their mechanical properties and to reduce inflammatory reactions. The immobilization of heparin could effectively inhibit thrombogenesis (Fig. 8C) [114]. However, it is still not commercially available for SDVGs to treat thrombosis, infection, aneurysms, and the cost for development is higher than existing synthetic grafts.
Coculture of cells
It is crucial to establish a proper microenvironment mimicking the in vivo-like condition of blood vessels for tissue regeneration (Fig. 9A). Lu et al. [115] studied the effect of endothelium-releasing vasoactive factors on vascular smooth muscle cell (VSMC) proliferation in the coculture system of isolated aortic endothelial cells (AECs) and the VSMCs. They observed that the endothelin-1 concentration increased in the coculture system compared with VSMCs cultured alone. This indicates some interactions between SMCs and ECs, affecting the proliferation of SMCs but not ECs. In addition, compared with SMCs cultured alone, the coculture system with ECs on patterned fibrous scaffolds could promote the extracellular matrix production of both ECs and SMCs, providing a promising technology in the design of tissue-engineered scaffolds to construct blood vessels (Fig. 9B) [116]. Kook et al. [117].fabricated a 3D mesh scaffold with HUVECs and adipose-derived mesenchymal stem cells (ADSCs) along the electrospun nanofibers It is reported that HUVECs and ADSCs co-cultured PCL/gelatin nanofiber scaffolds could accelerate mature and functional micro-vessels and a luminal structure with a higher expression of vascular markers. Kuzminska et al. [118] obtained prostheses with EC and SMC co-culture system as well as the REDV peptide that increased the hemocompatibility and EC adhesion, but decreased platelet adhesion.
Overall, electrospinning and cell sheet engineering are advantageous for producing multilayer structure with different types of cells each layer, mimicking similar fibrous structure of native ECM to enhance cell infiltration, cell adhesion, cell proliferation, and so on, while coculture of cells offers the cellular environment between cell–cell and cell-medium interactions. Similarly, molding also provides multilayer structure of SDVGs, but needs some reinforcements to improve their mechanical properties. The merit of 3D bioprinting is to fabricate automatically customized SDVGs with complex structures in the presence of cells, however, it is challenging to apply to the mass production due to its slow processing speed. In addition, the decellularization well preserves the extracellular matrix structure as well as favorable mechanical properties of native blood vessels, however, it is difficult to perfectly decellularize which may cause immune responses.
Conclusions and future perspective
With the development of technologies, the demand of SDVGs is also increasing for the cardiovascular reconstruction such as substitution for severely constricted or occluded blood vessels. To date, large or middles size diameter vascular grafts have achieved satisfactory results in the clinical application, and few technologies for SDVGs are already entering the stages of human clinical trials; however, it yielded limited success and it is still not commercially available for SDVGs to fulfill patient’s needs such as coronary, peripheral, and carotid arteries bypass surgery and arteriovenous access due to low patency after implantation. The key point is to resolve compliance mismatch between SDVGs and native vessels at the anastomosis site which results in intima hyperplasia, platelets adhesion, thrombus formation, stenosis, and immune system activation [119].
This review focused on the commonly used synthetic polymers used for SDVGs, and their surface modification strategies as well as various fabrication techniques for the long-term patency of SDVGs. The overall idea is to design multilayer vascular grafts, using synthetic polymers (ePTFE, PET, PU, PLA, or PCL) combined with natural polymers (collagen, elastin, gelatin, lecithin) introducing biologically active substances (peptides, vascular growth factors, antibodies, plasminogen activators) as well as specific cells (HUVECs, HUASMCs or fibroblasts) on each layer to mimic the composition of natural blood vessels as well as cellular environment in the human body [86], leading to better biocompatibility and the reduction of immune responses [23]. In terms of fabrication technologies, multilayer structures of SDVGs can be produced by electrospinning, molding, cell sheet engineering, or the combination of two or three fabrication technologies, making sure that SDVGs have adequate mechanical properties and biocompatibility. For example, electrospinning and coculture of cells could be combined to mimic ECM structure that facilitate to the infiltration, adhesion, and proliferation of specific cells. However, it is a challenge to fabricate complicated geometries via electrospinning or cell sheet engineering, whereas SDVGs with complicated geometries could be easily produced through molding or 3D bioprinting. Such an approach will combine the advantages of different biomaterials and various fabrication technologies for vascular reconstruction. In addition, decellularization of native blood vessels including allogenic and xenogeneic vessels (from porcine, bovine, etc.) is also a suitable technology for vascular reconstruction. Although it has a good ECM as well as mechanical properties, it is associated with the immune responses resulting in long-term failure.
Considering the above information of this review, it can be concluded that the production of SDVGs needs further improvement for commercialization. Future studies should optimize fabrication technologies with proper biomaterials and innovative technologies for surface modification, mimicking physiological environment in the body to the great extent. The surface modification of SDVGs should be focused on with the combination of “passive and active” strategies and their synergistic mechanisms to solve the thrombus formation in the initial stage as well as rapid reconstruction of SDVGs. For example, zwitterionic groups grafted on the synthetic polymers have anti-thrombotic effect [120], and REDV peptides grafted on SDVGs can selectively adhere endothelial cells to promote rapid endothelialization [57], which are passive strategy to prevent thrombus formation after implantation. Meanwhile, plasminogen activators, which is an active strategy, are also introduced combined with the above passive strategy to dissolve the fibrin formed at the early stage for the long-term patency of SDVGs. In addition, a better understanding of the correlation between biomaterials, surface modification, fabrication parameters, and performances would provide a mean to the create multi-functional long-term patency of SDVGs.
Acknowledgements
Not applicable.
Abbreviations
- 3D
Three-dimensional
- SDVGs
Small-diameter vascular grafts
- FGF
Fibroblast growth factor
- VEGF
Vascular endothelial growth factor
- HGF
Hepatocyte growth factor
- ECM
Extracellular matrix
- ePTFE
Expanded polytetrafluoroethylene
- PET
Polyethylene terephthalate
- PU
Polyurethane
- PLA
Polylactic acid
- PLLA
Poly-L-lactic acid
- PDLA
Poly-D-lactic acid
- PLGA
Poly(lactic-co-glycolic acid)
- PCL
Poly(-caprolactone)
- PGA
Poly (glycolic acid) (PGA)
- NO
Nitric oxide
- HUVECs
Human umbilical vein endothelial cells
- HUASMCs
Human umbilical artery smooth muscle cells
- HUAECs
Human umbilical artery endothelial cells
- ADSCs
Adipose-derived mesenchymal stem cells
- CHCl3
Chloroform
- EtOH
Ethanol
- DMF
N,N-dimethylformamide
- THF
Tetrahydrofuran
- HFIP
1,1,1,3,3,3-Hexafluoro-2-propanol
Authors’ contributions
W.Z., H.-J.L., and Y.K.J. conceptualized and designed the paper. M.-X.L. and Q.-Q.W. wrote the manuscript. M.-X.L., H.-L.M. and Y.R. collected and designed the figures and tables. W.Z. and H.-J.L. revised the manuscript. Y.K.J. supervised the manuscript. All authors read and approved the final manuscript.
Funding
This work was supported by Natural Science Foundation of Jiangsu Province (BK20220613), the Nantong Science and Technology Project (JC12022080), the Nano-Materials Technology Program (NRF-2021M3H4A1A04092878), the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (MSIT), Jiangsu University "Qinglan Project", and Talent Introduction Program of Nantong University (No. 135421615008).
Availability of data and materials
Not applicable.
Declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Mei-Xian Li and Qian-Qi Wei contributed equally to this work.
Change history
9/23/2023
A Correction to this paper has been published: 10.1186/s40824-023-00424-4
Contributor Information
Wei Zhang, Email: zhangwei@ntu.edu.cn.
Huan-Jun Lu, Email: huanjunlu@ntu.edu.cn.
Yoon Ki Joung, Email: ykjoung@kist.re.kr.
References
- 1.Virani SS, Alonso A, Aparicio HJ, Benjamin EJ, Bittencourt MS, Callaway CW, et al. Heart Disease and Stroke Statistics-2021 Update: A Report From the American Heart Association. Circulation. 2021;143:e254–743. doi: 10.1161/CIR.0000000000000950. [DOI] [PubMed] [Google Scholar]
- 2.Carrabba M, Madeddu P. Current Strategies for the Manufacture of Small Size Tissue Engineering Vascular Grafts. Front Bioeng Biotechnol. 2018;6:41. doi: 10.3389/fbioe.2018.00041. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Pashneh-Tala S, MacNeil S, Claeyssens F. The Tissue-Engineered Vascular Graft-Past, Present, and Future. Tissue Eng Part B-Rev. 2016;22:68–100. doi: 10.1089/ten.teb.2015.0100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Rathore A, Cleary M, Naito Y, Rocco K, Breuer C. Development of tissue engineered vascular grafts and application of nanomedicine. Wiley Interdiscip Rev-Nanomed Nanobiotechnol. 2012;4:257–272. doi: 10.1002/wnan.1166. [DOI] [PubMed] [Google Scholar]
- 5.Edelman ER. Vascular tissue engineering : designer arteries. Circ Res. 1999;85:1115–1117. doi: 10.1161/01.res.85.12.1115. [DOI] [PubMed] [Google Scholar]
- 6.Pietri P. Vascular grafts: in search of the ideal prosthesis. Int Surg. 1988;73:205. [PubMed] [Google Scholar]
- 7.el-Massry S, Saad E, Sauvage LR, Zammit M, Davis CC, Smith JC, et al. Axillofemoral bypass with externally supported, knitted Dacron grafts: a follow-up through twelve years. J Vasc Surg. 1993;17: 107–14. [DOI] [PubMed]
- 8.Ingle H, Fishwick G, Garnham A, Thompson MM, Bell PRF. Long-term results of endovascular AAA repair using a homemade aortomonoiliac PTFE device. J Endovascular Ther. 2002;9:481–487. doi: 10.1177/152660280200900416. [DOI] [PubMed] [Google Scholar]
- 9.Roll S, Muller-Nordhorn J, Keil T, Scholz H, Eidt D, Greiner W, et al. Dacron vs. PTFE as bypass materials in peripheral vascular surgery--systematic review and meta-analysis. BMC Surg. 2008;8: 22. [DOI] [PMC free article] [PubMed]
- 10.Wang B, Wang XL, Kenneth A, Drena A, Pacheco A, Kalvin L, et al. Developing small-diameter vascular grafts with human amniotic membrane: long-term evaluation of transplantation outcomes in a small animal model. Biofabrication. 2023;15:025004. doi: 10.1088/1758-5090/acb1da. [DOI] [PubMed] [Google Scholar]
- 11.Lu XJ, Zou H, Liao XK, Xiong Y, Hu XY, Cao J, et al. Construction of PCL-collagen@PCL@PCL-gelatin three-layer small diameter artificial vascular grafts by electrospinning. Biomed Mater. 2023;18:015008. doi: 10.1088/1748-605X/aca269. [DOI] [PubMed] [Google Scholar]
- 12.Liu DL, Han JX, Zhuang XJ, Gao Y, Wang WJ, Qin D, et al. Evaluation of mechanical properties and biocompatibility of three-layer PCL/PLLA small-diameter vascular graft with pore diameter gradient. Eur Polym J. 2023;186:111864. [Google Scholar]
- 13.Tennant M, McGeachie JK. Blood vessel structure and function: a brief update on recent advances. Aust NZ J Surg. 1990;60:747–753. doi: 10.1111/j.1445-2197.1990.tb07468.x. [DOI] [PubMed] [Google Scholar]
- 14.Heidenhain C, Veeravoorn A, Vachkov B, Weichert W, Schmidmaier G, Wildemann B, et al. Fibroblast and Vascular Endothelial Growth Factor Coating of Decellularized Vascular Grafts Stimulates Undesired Giant Cells and Graft Encapsulation in a Rat Model. Artif Organs. 2011;35:E1–E10. doi: 10.1111/j.1525-1594.2010.01072.x. [DOI] [PubMed] [Google Scholar]
- 15.Lee H, Chung HJ, Park TG. Perspectives on: Local and sustained delivery of angiogenic growth factors. J Bioact Compat Polym. 2007;22:89–114. [Google Scholar]
- 16.Lieb W, Safa R, Benjamin EJ, Xanthakis V, Yin XY, Sullivan LM, et al. Vascular endothelial growth factor, its soluble receptor, and hepatocyte growth factor: clinical and genetic correlates and association with vascular function. Eur Heart J. 2009;30:1121–1127. doi: 10.1093/eurheartj/ehp007. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Hibbert B, Olsen S, O'Brien E. Involvement of progenitor cells in vascular repair. Trends Cardiovasc Med. 2003;13:322–326. doi: 10.1016/j.tcm.2003.09.002. [DOI] [PubMed] [Google Scholar]
- 18.Ikeda Y, Fukuda N, Wada M, Matsumoto T, Satomi A, Yokoyama S, et al. Development of angiogenic cell and gene therapy by transplantation of umbilical cord blood with vascular endothelial growth factor gene. Hypertens Res. 2004;27:119–128. doi: 10.1291/hypres.27.119. [DOI] [PubMed] [Google Scholar]
- 19.Zhang L, Xu QB. Stem/Progenitor Cells in Vascular Regeneration. Arterioscler Thromb Vasc Biol. 2014;34:1114–1119. doi: 10.1161/ATVBAHA.114.303809. [DOI] [PubMed] [Google Scholar]
- 20.Zhu AP, Ming Z, Jian S. Blood compatibility of chitosan/heparin complex surface modified ePTFE vascular graft. Appl Surf Sci. 2005;241:485–492. [Google Scholar]
- 21.Tillman BW, Yazdani SK, Lee SJ, Geary RL, Atala A, Yoo JJ. The in vivo stability of electrospun polycaprolactone-collagen scaffolds in vascular reconstruction. Biomater Res. 2009;30:583–588. doi: 10.1016/j.biomaterials.2008.10.006. [DOI] [PubMed] [Google Scholar]
- 22.Hosseinzadeh S, Zarei-Behjani Z, Bohlouli M, Khojasteh A, Ghasemi N, Salehi-Nik N. Fabrication and optimization of bioactive cylindrical scaffold prepared by electrospinning for vascular tissue engineering. Iran Polym J. 2022;31:127–141. [Google Scholar]
- 23.Lee SJ, Yoo JJ, Lim GJ, Atala A, Stitzel J. In vitro evaluation of electrospun nanofiber scaffolds for vascular graft application. J Biomed Mater Res A. 2007;83:999–1008. doi: 10.1002/jbm.a.31287. [DOI] [PubMed] [Google Scholar]
- 24.Mallis P, Kostakis A, Stavropoulos-Giokas C, Michalopoulos E. Future perspectives in small-diameter vascular graft engineering. Bioengineering-Basel. 2020;7:160. [DOI] [PMC free article] [PubMed]
- 25.Wang S, Mo XM, Jiang BJ, Gao CJ, Wang HS, Zhuang YG, et al. Fabrication of small-diameter vascular scaffolds by heparin-bonded P(LLA-CL) composite nanofibers to improve graft patency. Int J Nanomed. 2013;8:2131–2139. doi: 10.2147/IJN.S44956. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Moreno MJ, Ajji A, Mohebbi-Kalhori D, Rukhlova M, Hadjizadeh A, Bureau MN. Development of a compliant and cytocompatible micro-fibrous polyethylene terephthalate vascular scaffold. J Biomed Mater Res Part B. 2011;97B:201–214. doi: 10.1002/jbm.b.31774. [DOI] [PubMed] [Google Scholar]
- 27.L'Heureux N, Dusserre N, Konig G, Victor B, Keire P, Wight TN, et al. Human tissue-engineered blood vessels for adult arterial revascularization. Nat Med. 2006;12:361–365. doi: 10.1038/nm1364. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Kim SH, Mun CH, Jung Y, Kim SH, Kim DI, Kim SH. Mechanical properties of compliant double layered poly(L-lactide-co-epsilon-caprolactone) vascular graft. Macromol Res. 2013;21:886–891. [Google Scholar]
- 29.Jirofti N, Mohebbi-Kalhori D, Samimi A, Hadjizadeh A, Kazemzadeh GH. Small-diameter vascular graft using co-electrospun composite PCL/PU nanofibers. Biomed Mater. 2018;13. [DOI] [PubMed]
- 30.Grasl C, Stoiber M, Rohrich M, Moscato F, Bergmeister H, Schima H. Electrospinning of small diameter vascular grafts with preferential fiber directions and comparison of their mechanical behavior with native rat aortas. Mater Sci Eng C-Mater Biol Appl. 2021;124:112085. [DOI] [PubMed]
- 31.Fang ZP, Xing YH, Wang H, Geng X, Ye L, Zhang AY, et al. Remodeling of structurally reinforced (TPU plus PCL/PCL)-Hep electrospun small-diameter bilayer vascular grafts interposed in rat abdominal aortas. Biomater Sci. 2022;10:4257–4270. doi: 10.1039/d1bm01653a. [DOI] [PubMed] [Google Scholar]
- 32.de Valence S, Tille JC, Mugnai D, Mrowczynski W, Gurny R, Moller M, et al. Long term performance of polycaprolactone vascular grafts in a rat abdominal aorta replacement model. Biomater Res. 2012;33:38–47. doi: 10.1016/j.biomaterials.2011.09.024. [DOI] [PubMed] [Google Scholar]
- 33.Adhikari KR, Zimmerman J, Dimble PS, Tucker BS, Thomas V. Kink-free electrospun PET/PU-based vascular grafts with 3D-printed additive manufacturing reinforcement. J Mater Res. 2021;36:4013–4023. [Google Scholar]
- 34.Tai NR, Salacinski HJ, Edwards A, Hamilton G, Seifalian AM. Compliance properties of conduits used in vascular reconstruction. Br J Surg. 2000;87:1516–1524. doi: 10.1046/j.1365-2168.2000.01566.x. [DOI] [PubMed] [Google Scholar]
- 35.Begovac PC, Thomson RC, Fisher JL, Hughson A, Gallhagen A. Improvements in GORE-TEX (R) Vascular Graft performance by Carmeda (R) BioActive Surface heparin immobilization. Eur J Vasc Endovasc Surg. 2003;25:432–437. doi: 10.1053/ejvs.2002.1909. [DOI] [PubMed] [Google Scholar]
- 36.Dekker A, Reitsma K, Beugeling T, Bantjes A, Feijen J, van Aken WG. Adhesion of endothelial cells and adsorption of serum proteins on gas plasma-treated polytetrafluoroethylene. Biomater Res. 1991;12:130–138. doi: 10.1016/0142-9612(91)90191-c. [DOI] [PubMed] [Google Scholar]
- 37.Pu FR, Williams RL, Markkula TK, Hunt JA. Expression of leukocyte-endothelial cell adhesion molecules on monocyte adhesion to human endothelial cells on plasma treated PET and PTFE in vitro. Biomater Res. 2002;23:4705–4718. doi: 10.1016/s0142-9612(02)00219-3. [DOI] [PubMed] [Google Scholar]
- 38.Walluscheck KP, Bierkandt S, Brandt M, Cremer J. Infrainguinal ePTFE vascular graft with bioactive surface heparin bonding - First clinical results. J Cardiovasc Surg. 2005;46:425–430. [PubMed] [Google Scholar]
- 39.Wang D, Xu Y, Lin YJ, Yilmaz G, Zhang J, Schmidt G, et al. Biologically Functionalized Expanded Polytetrafluoroethylene Blood Vessel Grafts. Biomacromol. 2020;21:3807–3816. doi: 10.1021/acs.biomac.0c00897. [DOI] [PubMed] [Google Scholar]
- 40.Wang D, Xu Y, Wang L, Wang X, Ren C, Zhang B, et al. Expanded Poly(tetrafluoroethylene) Blood Vessel Grafts with Embedded Reactive Oxygen Species (ROS)-Responsive Antithrombogenic Drug for Elimination of Thrombosis. ACS Appl Mater Interfaces. 2020;12:29844–29853. doi: 10.1021/acsami.0c07868. [DOI] [PubMed] [Google Scholar]
- 41.Wang DF, Xu YY, Wang LX, Wang XF, Yan SJ, Yilmaz G, et al. Long-term nitric oxide release for rapid endothelialization in expanded polytetrafluoroethylene small-diameter artificial blood vessel grafts. Appl Surf Sci. 2020;507.
- 42.Friedman SG, Lazzaro RS, Spier LN, Moccio C, Tortolani AJ. A prospective randomized comparison of Dacron and polytetrafluoroethylene aortic bifurcation grafts. Surgery. 1995;117:7–10. doi: 10.1016/s0039-6060(05)80223-5. [DOI] [PubMed] [Google Scholar]
- 43.Nevelsteen A, Wouters L, Suy R. Aortofemoral dacron reconstruction for aorto-iliac occlusive disease: a 25-year survey. Eur J Vasc Endovasc Surg. 1991;5:179–186. doi: 10.1016/s0950-821x(05)80685-1. [DOI] [PubMed] [Google Scholar]
- 44.Wang XW, Lin P, Yao QH, Chen CY. Development of small-diameter vascular grafts. World J Surg. 2007;31:682–689. doi: 10.1007/s00268-006-0731-z. [DOI] [PubMed] [Google Scholar]
- 45.Xie XY, Eberhart A, Guidoin R, Marois Y, Douville Y, Zhang Z. Five Types of Polyurethane Vascular Grafts in Dogs: The Importance of Structural Design and Material Selection. J Biomater Sci-Polym Ed. 2010;21:1239–1264. doi: 10.1163/092050609X12481751806295. [DOI] [PubMed] [Google Scholar]
- 46.Nottelet B, Pektok E, Mandracchia D, Tille JC, Walpoth B, Gurny R, et al. Factorial design optimization and in vivo feasibility of poly(epsilon-caprolactone)-micro- and narofiber-based small diameter vascular grafts. J Biomed Mater Res A. 2009;89A:865–875. doi: 10.1002/jbm.a.32023. [DOI] [PubMed] [Google Scholar]
- 47.Chen X, Lin Z, Feng Y, Tan H, Xu X, Luo J, et al. Zwitterionic PMCP-Modified Polycaprolactone Surface for Tissue Engineering: Antifouling, Cell Adhesion Promotion, and Osteogenic Differentiation Properties. Small. 2019;15:e1903784. doi: 10.1002/smll.201903784. [DOI] [PubMed] [Google Scholar]
- 48.Cuenca JP, Padalhin A, Lee BT. Small-diameter decellularized vascular graft with electrospun polycaprolactone. Mater Lett. 2021;284.
- 49.Xue L, Greisler HP. Biomaterials in the development and future of vascular grafts. J Vasc Surg. 2003;37:472–480. doi: 10.1067/mva.2003.88. [DOI] [PubMed] [Google Scholar]
- 50.Khalifehzadeh R, Ciridon W, Ratner BD. Surface fluorination of polylactide as a path to improve platelet associated hemocompatibility. Acta Biomater. 2018;78:23–35. doi: 10.1016/j.actbio.2018.07.042. [DOI] [PubMed] [Google Scholar]
- 51.Buscemi S, Palumbo VD, Maffongelli A, Fazzotta S, Palumbo FS, Licciardi M, et al. Electrospun PHEA-PLA/PCL Scaffold for Vascular Regeneration: A Preliminary in Vivo Evaluation. Transplant Proc. 2017;49:716–721. doi: 10.1016/j.transproceed.2017.02.017. [DOI] [PubMed] [Google Scholar]
- 52.Leyva-Verduzco AA, Castillo-Ortega MM, Chan-Chan LH, Silva-Campa E, Galaz-Mendez R, Vera-Graziano R, et al. Electrospun tubes based on PLA, gelatin and genipin in different arrangements for blood vessel tissue engineering. Polym Bull. 2020;77:5985–6003. [Google Scholar]
- 53.Nguyen TH, Lee BT. The effect of cross-linking on the microstructure, mechanical properties and biocompatibility of electrospun polycaprolactone-gelatin/PLGA-gelatin/PLGA-chitosan hybrid composite. Sci Technol Adv Mater. 2012;13. [DOI] [PMC free article] [PubMed]
- 54.Ji Y, Wei Y, Liu XS, Wang JL, Ren KF, Ji J. Zwitterionic polycarboxybetaine coating functionalized with REDV peptide to improve selectivity for endothelial cells. J Biomed Mater Res A. 2012;100A:1387–1397. doi: 10.1002/jbm.a.34077. [DOI] [PubMed] [Google Scholar]
- 55.Du H, Li C, Luan YF, Liu Q, Yang WK, Yu Q, et al. An antithrombotic hydrogel with thrombin-responsive fibrinolytic activity: breaking down the clot as it forms. Mater Horizons. 2016;3:556–562. [Google Scholar]
- 56.Ren X, Feng Y, Guo J, Wang H, Li Q, Yang J, et al. Surface modification and endothelialization of biomaterials as potential scaffolds for vascular tissue engineering applications. Chem Soc Rev. 2015;44:5680–5742. doi: 10.1039/c4cs00483c. [DOI] [PubMed] [Google Scholar]
- 57.Ding X, Chin W, Lee CN, Hedrick JL, Yang YY. Peptide-functionalized polyurethane coatings prepared via grafting-to strategy to selectively promote endothelialization. Adv Healthc Mater. 2018;7. [DOI] [PubMed]
- 58.Weekes A, Bartnikowski N, Pinto N, Jenkins J, Meinert C, Klein TJ. Biofabrication of small diameter tissue-engineered vascular grafts. Acta Biomater. 2022;138:92–111. doi: 10.1016/j.actbio.2021.11.012. [DOI] [PubMed] [Google Scholar]
- 59.Hobby JA. Fibrinolytic activity in vascular grafts. Plast Reconstr Surg. 1978;61:97–101. doi: 10.1097/00006534-197801000-00017. [DOI] [PubMed] [Google Scholar]
- 60.Gunawan ST, Kempe K, Bonnard T, Cui J, Alt K, Law LS, et al. Multifunctional Thrombin-Activatable Polymer Capsules for Specific Targeting to Activated Platelets. Adv Mater. 2015;27:5153–5157. doi: 10.1002/adma.201502243. [DOI] [PubMed] [Google Scholar]
- 61.Lin KY, Lo JH, Consul N, Kwong GA, Bhatia SN. Self-titrating anticoagulant nanocomplexes that restore homeostatic regulation of the coagulation cascade. ACS Nano. 2014;8:8776–8785. doi: 10.1021/nn501129q. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Fu J, Wang M, De Vlaminck I, Wang Y. Thick PCL Fibers Improving Host Remodeling of PGS-PCL Composite Grafts Implanted in Rat Common Carotid Arteries. Small. 2020;16:e2004133. doi: 10.1002/smll.202004133. [DOI] [PubMed] [Google Scholar]
- 63.Jing X, Mi HY, Salick MR, Cordie TM, Peng XF, Turng LS. Electrospinning thermoplastic polyurethane/graphene oxide scaffolds for small diameter vascular graft applications. Mater Sci Eng C Mater Biol Appl. 2015;49:40–50. doi: 10.1016/j.msec.2014.12.060. [DOI] [PubMed] [Google Scholar]
- 64.Yi BC, Yu L, Tang H, Wang WB, Liu W, Zhang YZ. Lysine-doped polydopamine coating enhances antithrombogenicity and endothelialization of an electrospun aligned fibrous vascular graft. Appl Mater Today. 2021;25.
- 65.Zhao QL, Wang J, Cui HQ, Chen HX, Wang YL, Du XM. Programmed shape-morphing scaffolds enabling facile 3D endothelialization. Adv Funct Mater. 2018;28.
- 66.Mi HY, Jing X, McNulty J, Salick MR, Peng XF, Turng LS. Approaches to Fabricating Multiple-Layered Vascular Scaffolds Using Hybrid Electrospinning and Thermally Induced Phase Separation Methods. Ind Eng Chem Res. 2016;55:882–892. [Google Scholar]
- 67.Wang W, Liu D, Li D, Du H, Zhang J, You Z, et al. Nanofibrous vascular scaffold prepared from miscible polymer blend with heparin/stromal cell-derived factor-1 alpha for enhancing anticoagulation and endothelialization. Colloids Surf B Biointerfaces. 2019;181:963–972. doi: 10.1016/j.colsurfb.2019.06.065. [DOI] [PubMed] [Google Scholar]
- 68.Norouzi SK, Shamloo A. Bilayered heparinized vascular graft fabricated by combining electrospinning and freeze drying methods. Mater Sci Eng C Mater Biol Appl. 2019;94:1067–1076. doi: 10.1016/j.msec.2018.10.016. [DOI] [PubMed] [Google Scholar]
- 69.Yao WC, Gu HB, Hong T, Wang Y, Chen SH, Mo XM, et al. A bi-layered tubular scaffold for effective anti-coagulant in vascular tissue engineering. Mater Des. 2020;194.
- 70.Kabirian F, Brouki Milan P, Zamanian A, Heying R, Mozafari M. Nitric oxide-releasing vascular grafts: A therapeutic strategy to promote angiogenic activity and endothelium regeneration. Acta Biomater. 2019;92:82–91. doi: 10.1016/j.actbio.2019.05.002. [DOI] [PubMed] [Google Scholar]
- 71.Zhou X, Nowicki M, Sun H, Hann SY, Cui H, Esworthy T, et al. 3D Bioprinting-Tunable Small-Diameter Blood Vessels with Biomimetic Biphasic Cell Layers. ACS Appl Mater Interfaces. 2020;12:45904–45915. doi: 10.1021/acsami.0c14871. [DOI] [PubMed] [Google Scholar]
- 72.Jia WB, Li M, Weng HJ, Gu GF, Chen ZG. Design and comprehensive assessment of a biomimetic tri-layer tubular scaffold via biodegradable polymers for vascular tissue engineering applications. Mater Sci Eng C-Mater Biol Appl. 2020;110. [DOI] [PubMed]
- 73.Hu QX, Wu C, Zhang HG. Preparation and Optimization of a Biomimetic Triple-Layered Vascular Scaffold Based on Coaxial Electrospinning. Appl Biochem Biotechnol. 2020;190:1106–1123. doi: 10.1007/s12010-019-03147-2. [DOI] [PubMed] [Google Scholar]
- 74.Kai D, Liow SS, Loh XJ. Biodegradable polymers for electrospinning: Towards biomedical applications. Mater Sci Eng C-Mater Biol Appl. 2014;45:659–670. doi: 10.1016/j.msec.2014.04.051. [DOI] [PubMed] [Google Scholar]
- 75.Khalili S, Khorasani SN, Razavi SM, Hashemibeni B, Tamayol A. Nanofibrous Scaffolds with Biomimetic Composition for Skin Regeneration. Appl Biochem Biotechnol. 2019;187:1193–1203. doi: 10.1007/s12010-018-2871-7. [DOI] [PubMed] [Google Scholar]
- 76.Ribba L, Parisi M, D'Accorso NB, Goyanes S. Electrospun Nanofibrous Mats: From Vascular Repair to Osteointegration. J Biomed Nanotechnol. 2014;10:3508–3535. doi: 10.1166/jbn.2014.2046. [DOI] [PubMed] [Google Scholar]
- 77.Wang ZH, Cui Y, Wang JN, Yang XH, Wu YF, Wang K, et al. The effect of thick fibers and large pores of electrospun poly(epsilon-caprolactone) vascular grafts on macrophage polarization and arterial regeneration. Biomater Res. 2014;35:5700–5710. doi: 10.1016/j.biomaterials.2014.03.078. [DOI] [PubMed] [Google Scholar]
- 78.Ma HY, Hu JA, Ma PX. Polymer Scaffolds for Small-Diameter Vascular Tissue Engineering. Adv Funct Mater. 2010;20:2833–2841. doi: 10.1002/adfm.201000922. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Cutiongco MFA, Goh SH, Aid-Launais R, Le Visage C, Low HY, Yim EKF. Planar and tubular patterning of micro and nano-topographies on poly(vinyl alcohol) hydrogel for improved endothelial cell responses. Biomater Res. 2016;84:184–195. doi: 10.1016/j.biomaterials.2016.01.036. [DOI] [PubMed] [Google Scholar]
- 80.Guan GP, Yu CL, Xing MY, Wu YF, Hu XY, Wang HJ, et al. Hydrogel Small-Diameter Vascular Graft Reinforced with a Braided Fiber Strut with Improved Mechanical Properties. Polymers. 2019;11:810. doi: 10.3390/polym11050810. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Liu SS, Dong CF, Lu GZ, Lu Q, Li ZX, Kaplan DL, et al. Bilayered vascular grafts based on silk proteins. Acta Biomater. 2013;9:8991–9003. doi: 10.1016/j.actbio.2013.06.045. [DOI] [PubMed] [Google Scholar]
- 82.Roh JD, Nelson GN, Brennan MP, Mirensky TL, Yi T, Hazlett TF, et al. Small-diameter biodegradable scaffolds for functional vascular tissue engineering in the mouse model. Biomater Res. 2008;29:1454–1463. doi: 10.1016/j.biomaterials.2007.11.041. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Wenger R, Giraud MN. 3D Printing Applied to Tissue Engineered Vascular Grafts. Appl Sci-Basel. 2018;8:2631. [Google Scholar]
- 84.Jia W, Gungor-Ozkerim PS, Zhang YS, Yue K, Zhu K, Liu W, et al. Direct 3D bioprinting of perfusable vascular constructs using a blend bioink. Biomater Res. 2016;106:58–68. doi: 10.1016/j.biomaterials.2016.07.038. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Pi Q, Maharjan S, Yan X, Liu X, Singh B, van Genderen AM, et al. Digitally Tunable Microfluidic Bioprinting of Multilayered Cannular Tissues. Adv Mater. 2018;30:e1706913. doi: 10.1002/adma.201706913. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 86.Yuan B, Jin Y, Sun Y, Wang D, Sun JS, Wang Z, et al. A strategy for depositing different types of cells in three dimensions to mimic tubular structures in tissues. Adv Mater. 2012;24: 890-+. [DOI] [PubMed]
- 87.Backman DE, LeSavage BL, Shah SB, Wong JY. A Robust Method to Generate Mechanically Anisotropic Vascular Smooth Muscle Cell Sheets for Vascular Tissue Engineering. Macromol Biosci. 2017;17:1600434. doi: 10.1002/mabi.201600434. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Yamato M, Okano T. Cell sheet engineering Mater Today. 2004;7:42–47. [Google Scholar]
- 89.Kaushal S, Amiel GE, Guleserian KJ, Shapira OM, Perry T, Sutherland FW, et al. Functional small-diameter neovessels created using endothelial progenitor cells expanded ex vivo. Nat Med. 2001;7:1035–1040. doi: 10.1038/nm0901-1035. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90.Lin CH, Hsia K, Ma H, Lee H, Lu JH. In Vivo Performance of Decellularized Vascular Grafts: A Review Article. Int J Mol Sci. 2018;19:2101. doi: 10.3390/ijms19072101. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91.Spark JI, Yeluri S, Derham C, Wong YT, Leitch D. Incomplete cellular depopulation may explain the high failure rate of bovine ureteric grafts. Br J Surg. 2008;95:582–585. doi: 10.1002/bjs.6052. [DOI] [PubMed] [Google Scholar]
- 92.Syedain Z, Reimer J, Lahti M, Berry J, Johnson S, Tranquillo RT. Tissue engineering of acellular vascular grafts capable of somatic growth in young lambs. Nat Commun. 2016;7:12951. doi: 10.1038/ncomms12951. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Fillinger MF, Sampson LN, Cronenwett JL, Powell RJ, Wagner RJ. Coculture of endothelial cells and smooth muscle cells in bilayer and conditioned media models. J Surg Res. 1997;67:169–178. doi: 10.1006/jsre.1996.4978. [DOI] [PubMed] [Google Scholar]
- 94.Miki Y, Ono K, Hata S, Suzuki T, Kumamoto H, Sasano H. The advantages of co-culture over mono cell culture in simulating in vivo environment. J Steroid Biochem Mol Biol. 2012;131:68–75. doi: 10.1016/j.jsbmb.2011.12.004. [DOI] [PubMed] [Google Scholar]
- 95.Ye L, Cao J, Chen LM, Geng X, Zhang AY, Guo LR, et al. The fabrication of double layer tubular vascular tissue engineering scaffold via coaxial electrospinning and its 3D cell coculture. J Biomed Mater Res A. 2015;103:3863–3871. doi: 10.1002/jbm.a.35531. [DOI] [PubMed] [Google Scholar]
- 96.McClellan P, Landis WJ. Recent Applications of Coaxial and Emulsion Electrospinning Methods in the Field of Tissue Engineering. Biores Open Access. 2016;5:212–227. doi: 10.1089/biores.2016.0022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97.Qin K, Wu YF, Pan YW, Wang K, Kong DL, Zhao Q. Implantation of Electrospun Vascular Grafts with Optimized Structure in a Rat Model. J Vis Exp. 2018;136:e57340. doi: 10.3791/57340. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98.Wang Z, Liu C, Xiao Y, Gu X, Xu Y, Dong N, et al. Remodeling of a Cell-Free Vascular Graft with Nanolamellar Intima into a Neovessel. ACS Nano. 2019;13:10576–10586. doi: 10.1021/acsnano.9b04704. [DOI] [PubMed] [Google Scholar]
- 99.Xiang P, Li M, Zhang CY, Chen DL, Zhou ZH. Cytocompatibility of electrospun nanofiber tubular scaffolds for small diameter tissue engineering blood vessels. Int J Biol Macromol. 2011;49:281–288. doi: 10.1016/j.ijbiomac.2011.05.004. [DOI] [PubMed] [Google Scholar]
- 100.Aydogdu MO, Chou J, Altun E, Ekren N, Cakmak S, Eroglu M, et al. Production of the biomimetic small diameter blood vessels for cardiovascular tissue engineering. Int J Polym Mater Polym Biomat. 2019;68:243–255. [Google Scholar]
- 101.Wang GX, Qiu JH, Zhu JH, Zhang H, Guidoin R, Tang C. Novel Vascular Graft With Helical Slot Inhibits Thrombosis and Intimal Hyperplasia. Hypertension. 2010;56:1175–1275. [Google Scholar]
- 102.Guo X, Zhu J, Zhang H, You Z, Morsi Y, Mo X, et al. Facile preparation of a controlled-release tubular scaffold for blood vessel implantation. J Colloid Interface Sci. 2019;539:351–360. doi: 10.1016/j.jcis.2018.12.086. [DOI] [PubMed] [Google Scholar]
- 103.Guo JY, Huang JX, Lei SJ, Wan DD, Liang BY, Yan HY, et al. Construction of Rapid Extracellular Matrix-Deposited Small- Diameter Vascular Grafts Induced by Hypoxia in a Bioreactor. ACS Biomater Sci Eng. 2023;9:844–855. doi: 10.1021/acsbiomaterials.2c00809. [DOI] [PubMed] [Google Scholar]
- 104.Wang ZY, Mithieux SM, Weiss A. Fabrication Techniques for Vascular and Vascularized Tissue Engineering. Adv Healthc Mater. 2019;8:1900742. doi: 10.1002/adhm.201900742. [DOI] [PubMed] [Google Scholar]
- 105.Zhen L, Creason SA, Simonovsky FI, Snyder JM, Lindhartsen SL, Mecwan MM, et al. Precision-porous polyurethane elastomers engineered for application in pro-healing vascular grafts: Synthesis, fabrication and detailed biocompatibility assessment. Biomater Res. 2021;279:121174. doi: 10.1016/j.biomaterials.2021.121174. [DOI] [PubMed] [Google Scholar]
- 106.Saunders RE, Derby B. Inkjet printing biomaterials for tissue engineering: bioprinting. Int Mater Rev. 2014;59:430–448. [Google Scholar]
- 107.Yang GH, Kang D, An S, Ryu JY, Lee K, Kim JS, et al. Advances in the development of tubular structures using extrusion-based 3D cell-printing technology for vascular tissue regenerative applications. Biomater Res. 2022;26. [DOI] [PMC free article] [PubMed]
- 108.Nahmias Y, Schwartz RE, Verfaillie CM, Odde DJ. Laser-guided direct writing for three-dimensional tissue engineering. Biotechnol Bioeng. 2005;92:129–136. doi: 10.1002/bit.20585. [DOI] [PubMed] [Google Scholar]
- 109.Sekine H, Okano T. Capillary Networks for Bio-Artificial Three-Dimensional Tissues Fabricated Using Cell Sheet Based Tissue Engineering. Int J Mol Sci. 2021;22:92. doi: 10.3390/ijms22010092. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110.Ahn H, Ju YM, Takahashi H, Williams DF, Yoo JJ, Lee SJ, et al. Engineered small diameter vascular grafts by combining cell sheet engineering and electrospinning technology. Acta Biomater. 2015;16:14–22. doi: 10.1016/j.actbio.2015.01.030. [DOI] [PubMed] [Google Scholar]
- 111.Shimizu T, Sekine H, Yang J, Isoi Y, Yamato M, Kikuchi A, et al. Polysurgery of cell sheet grafts overcomes diffusion limits to produce thick, vascularized myocardial tissues. Faseb J. 2006;20: 708-+. [DOI] [PubMed]
- 112.Massaro MS, Kochova P, Palek R, Rosendorf J, Cervenkova L, Dahmen U, et al. Decellularization of Porcine Carotid Arteries: From the Vessel to the High-Quality Scaffold in Five Hours. Front Bioeng Biotechnol. 2022;10:833244. doi: 10.3389/fbioe.2022.833244. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113.Porzionato A, Sfriso MM, Pontini A, Macchi V, Buompensiere MI, Petrelli L, et al. Development of Small-Diameter Vascular Grafts Through Decellularization of Human Blood Vessels. J Biomater Tissue Eng. 2017;7:101–110. [Google Scholar]
- 114.Cai ZW, Gu YQ, Cheng J, Li J, Xu ZQ, Xing YH, et al. Decellularization, cross-linking and heparin immobilization of porcine carotid arteries for tissue engineering vascular grafts. Cell Tissue Banking. 2019;20:569–578. doi: 10.1007/s10561-019-09792-5. [DOI] [PubMed] [Google Scholar]
- 115.Lu MH, Chao CF, Huang CG, Chang LT. Coculture of vascular endothelial cells and smooth muscle cells from spontaneously hypertensive rats. Clin Exp Hypertens. 2003;25:413–425. doi: 10.1081/ceh-120024985. [DOI] [PubMed] [Google Scholar]
- 116.Li HN, Liu YW, Lu JF, Wei JJ, Li XH. Micropatterned coculture of vascular endothelial and smooth muscle cells on layered electrospun fibrous mats toward blood vessel engineering. J Biomed Mater Res A. 2015;103:1949–1960. doi: 10.1002/jbm.a.35332. [DOI] [PubMed] [Google Scholar]
- 117.Kook YM, Kim H, Kim S, Lee K, Heo CY, Park MH, et al. Promotion of Vascular Morphogenesis of Endothelial Cells Co-Cultured with Human Adipose-Derived Mesenchymal Stem Cells Using Polycaprolactone/Gelatin Nanofibrous Scaffolds. Nanomaterials. 2018;8:117. doi: 10.3390/nano8020117. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Kuzminska A, Wojciechowska A, Butruk-Raszeja BA. Vascular Polyurethane Prostheses Modified with a Bioactive Coating-Physicochemical, Mechanical and Biological Properties. Int J Mol Sci. 2021;22:12183. doi: 10.3390/ijms222212183. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 119.Patterson JT, Gilliland T, Maxfield MW, Church S, Naito Y, Shinoka T, et al. Tissue-engineered vascular grafts for use in the treatment of congenital heart disease: from the bench to the clinic and back again. Regen Med. 2012;7:409–419. doi: 10.2217/rme.12.12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120.Choi SY, Li MX, Kang JH, Yang DH, Joung YK. Anti-thrombotic polymer surfaces modified with zwitterionic and fluorinated surface-migrating oligomers. Surfaces and Interfaces. 2021;25.
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Not applicable.