. 2023 May 12;30(7):1349–1361. doi: 10.1093/jamia/ocad075

Deployment of machine learning algorithms to predict sepsis: systematic review and application of the SALIENT clinical AI implementation framework

Anton H van der Vegt 1,, Ian A Scott 2, Krishna Dermawan 3, Rudolf J Schnetler 4, Vikrant R Kalke 5, Paul J Lane 6
PMCID: PMC10280361  PMID: 37172264

Abstract

Objective

To retrieve and appraise studies of deployed artificial intelligence (AI)-based sepsis prediction algorithms using systematic methods, identify implementation barriers, enablers, and key decisions and then map these to a novel end-to-end clinical AI implementation framework.

Materials and Methods

Systematically review studies of clinically applied AI-based sepsis prediction algorithms in regard to methodological quality, deployment and evaluation methods, and outcomes. Identify contextual factors that influence implementation and map these factors to the SALIENT implementation framework.

Results

The review identified 30 articles of algorithms applied in adult hospital settings, with 5 studies reporting significantly decreased mortality post-implementation. Eight groups of algorithms were identified, each sharing a common algorithm. We identified 14 barriers, 26 enablers, and 22 decision points which were able to be mapped to the 5 stages of the SALIENT implementation framework.

Discussion

Empirical studies of deployed sepsis prediction algorithms demonstrate their potential for improving care and reducing mortality but reveal persisting gaps in existing implementation guidance. In the examined publications, key decision points reflecting real-word implementation experience could be mapped to the SALIENT framework and, as these decision points appear to be AI-task agnostic, this framework may also be applicable to non-sepsis algorithms. The mapping clarified where and when barriers, enablers, and key decisions arise within the end-to-end AI implementation process.

Conclusions

A systematic review of real-world implementation studies of sepsis prediction algorithms was used to validate an end-to-end staged implementation framework that has the ability to account for key factors that warrant attention in ensuring successful deployment, and which extends on previous AI implementation frameworks.

Keywords: sepsis prediction, systematic review, AI implementation, machine learning, artificial intelligence

INTRODUCTION

Sepsis accounts for nearly 20% of deaths worldwide, killing over 11 million people in 2017.1 Sepsis has been defined as a “life-threatening organ dysfunction caused by a dysregulated host response to infection”.2,3 Early recognition and treatment of sepsis can reduce mortality, and rule-based surveillance systems for detecting sepsis in hospital settings can improve outcomes.4,5

More recently, sepsis prediction algorithms employing artificial intelligence (AI),6–8 herein called machine learning algorithms (MLAs), that can detect evolving sepsis in patients earlier than rule-based methods, have proliferated.9,10 Most MLA studies assess performance based on static training and testing data collected retrospectively and analyzed in silico,11 whereas healthcare providers seek to implement MLAs in dynamic, complex real-world clinical settings using live or near-live data.

Theoretical MLA implementation frameworks12–16 have attempted to identify key stages, tasks and contextual factors that warrant consideration, but practical translation into end-to-end MLA implementation in clinical practice is uncertain. While systematic reviews have evaluated pre-implementation studies of sepsis MLAs,6–8,11,17 including interviews generating implementation methods,18 none have focused on MLAs actually implemented. Individual studies of deployed MLAs have revealed barriers and enablers that implementation frameworks must incorporate if they are to fully inform successful end-to-end MLA implementation.18–20

In this article, we identified and appraised studies of clinically applied sepsis MLAs using systematic methods and then map the serial steps in deployment described in these studies to a recently derived AI implementation framework, called SALIENT (reported in a companion paper21 and described in brief below). The mapping sought to clarify where and when barriers, enablers, and key decisions arise within the end-to-end AI implementation process and to validate SALIENT’s capability to guide stakeholders involved in end-to-end MLA implementation.

Background

The process by which AI interventions are evaluated at any given stage in the implementation cycle is maturing. The recently reported Decide-AI research reporting guidelines depict key stages of algorithm development, evaluation, and implementation,22 (Figure 1) which, in the companion paper to this work,21 were mapped to Stead et al’s multi-stage approach to translating medical informatics interventions from the lab to the field.12 This mapping was used to derive an end-to-end AI implementation framework, called SALIENT (Figure 3 and fully described elsewhere21), which accounted for factors found to be missing in many implementation frameworks when subjected to the Stead et al’s taxonomy,12,13,16,23,24 that is, components, both technical and clinical, that need to be developed, evaluated, and integrated over several stages.

Figure 3.

Figure 3.

The number of barriers (red badge), enablers (green badge), and decision points (blue badge), denoted by the number within the badge, mapped to each stage and component of the SALIENT AI implementation framework. Implementation stages are labeled in the title row from left to right. The color-coded solution components are developed in row B, and consist of Clinical workflow (blue), AI model (yellow), data pipeline (green), and human-computer interface (red). The components are integrated in rows C and D, and rows F and G describe cross-stage elements required throughout the entire implementation process, such as governance and quality and safety assurance. w/flow: workflow; dev/test: development & test; HCI: human computer interface.

The resulting SALIENT stages and associated reporting guidelines are: (I) Definition; (II) Retrospective study—TRIPOD(-AI)25,26; (III) Silent trial—TRIPOD(-AI)25,26; (IV) Pilot trial—Decide-AI22; and (V) Large trial/roll-out—CONSORT(-AI).27 The SALIENT framework integrates all elements of the reporting standards, and, compared to prior frameworks, renders all components of the end-to-end solution, how and when they integrate, and underlying implementation tasks (not shown here) fully visible. However, similar to most prior frameworks, SALIENT has not been validated in its ability to accommodate reported real-world AI implementation stages, barriers, enablers, and decisions.

OBJECTIVE

This study had 2 objectives: (1) conduct a systematic review of real-world implementation studies of sepsis MLAs in clinical practice and extract information into how MLA performance, adoption, and different implementation modes were assessed and impacted clinical care processes and patient outcomes; and (2) map the findings regarding barriers, enablers, and key decision points to the different stages and components of the SALIENT AI implementation framework to assess its potential utility for guiding real-world MLA implementation.

MATERIALS AND METHODS

Systematic review of sepsis MLA implementation studies

Search strategy

The systematic review was performed according to PRISMA guidelines.28 Five databases (Pubmed/Medline, EMBASE, Scopus, Web of Science, and clinicaltrials.gov.) were searched between January 1, 2012 and June 23, 2022 for titles and abstracts published in English using keywords and synonyms for: (1) predict; AND (2) sepsis; AND (3) machine learning; AND (4) trial; and NOT (5) child (see Supplementary Appendix SA for complete search queries).

A forwards and backwards citation search (snowballing strategy) was then applied to included papers to identify additional articles that reported new MLAs, or, provided further information about a sepsis MLA described in previously included papers. The latter were labeled linked papers, describing MLAs at different stages of implementation, but not considered primary articles.

Study selection

Studies of any design were included if: MLAs were applied to adult patients in hospital settings in whom sepsis was formally defined; used live or near-live data; and reported at least one or more algorithm performance metrics (full details in Supplementary Appendix SB). Covidence software29 supported a 2-stage screening process with screening of articles by 2 independent reviewers (AHvdV and RJS), with conflicts agreed by 3-way consensus (AHvdV, RJS, and KD); and full-text review by 2 independent reviewers (AHvdV and KD), with selection agreed by 3-way consensus (AHvdV, RJS, and KD). Snowballing was then applied to all included papers and any new or linked papers were identified by AHvdV and verified by KD.

Data extraction

Data were extracted independently by 2 authors (AHvdV and KD) using Excel templates, with disagreements resolved by consensus of 2 other authors (RJS and IAS). Extracted data included study metadata, implementation stage, care setting, MLA details including training and validation datasets, performance metrics, outcome definitions and events, and implementation barriers, enablers, and decision points (see Supplementary Appendix SC for more details). Decision points were identified when 2 or more studies chose different options at a certain point in implementation. Barriers were defined as pitfalls or problems hindering implementation success and enablers as tips or activities aiding implementation success. Consensus between authors (AHvdV, PL, and IAS) determined which decisions, enablers and barriers to include as found and which to consolidate under a common title to minimize overlap.

Quality assessment

Papers reporting all-cause or sepsis-related mortality underwent risk of bias (RoB) assessment, performed independently by 2 authors (AHvdV and VRK), using either the ROBINS-I tool30 for non-randomized studies, or the Cochrane RoB 2 tool31 for randomized trials. Mortality was chosen for RoB assessment as it was the most frequently reported and patient-critical measure.

Application of AI implementation framework

The systematic review findings for barriers, enablers, and decision points were mapped by AHvdV to the stages and elements of the SALIENT implementation framework, followed by a review by IAS and adjustments made where discrepancies were found. An item could be mapped to more than one element and where no obvious element was found to map to, it was recorded.

RESULTS

Systematic review of sepsis MLA implementation studies

From 3133 retrieved abstracts, 1126 duplicates were removed, leaving 2007 for screening, from which 12 full-text studies were included for analysis (Figure 1). Most excluded studies were not sepsis prediction studies, or were rule-based rather than AI-based algorithms or were not implemented. An additional 7 articles found by snowballing were selected, yielding a 19 included papers as primary articles, with further snowballing yielding 11 linked papers, giving a total of 30 articles.32–61

Figure 1.

Figure 1.

Flowchart for study selection.

Study characteristics

All 30 studies were published between 2015 and 2022, with 8 algorithm groups (A to H) identified according to the common or named MLA that was the focus of study (Table 1); all were US-based except for Group (C), which was Brazilian. Five groups (A, B, E, F, H) implemented MLAs with a quantitative evaluation (before-after,33,50,59–61 randomized controlled trial,58 2-armed cohort study,46 prospective observational,33,44,48,53 retrospective observational34). Two other groups (C, D) provided case studies35,41,43 or qualitative evaluations42 and one group (G) reported only post-implementation analyses (retrospective51 or difference-in-difference52). Groups (B, E) conducted the only multicenter trials with outcomes of more than 10 000 sepsis episodes.46,61 Median trial length was 14 months (range 2–79) and median time between publishing a retrospective study on MLA development and an implementation study was 3 years (range 1–7).

Table 1.

Listing of studies identified in systematic review, grouped by MLA

Group Reference SALIENT stagea Study design (# sites) Study period Care location Outcomeb count (prevalence)
A (EWS 2.0) Taylor et al., 201632 II R (3) ED 1056 (4.7)
  • University of Pennsylvania.

  •  MLA = random forest; 587 features

Giannini et al., 201933 II R (3) Non-ICU 347 (3.3)
III PO (2) Jan–Jun’16 Non-ICU 1540
V BA (2) Jul’16–Feb’17 Non-ICU 2137
Ginestra et al., 201944 Post PO (1) Nov–Dec’16 Non-ICU NA
  • B (Insight)

  • Dascena Inc and University of California. MLA = various, Inc. Gradient boosted trees29 and logistic regression45, 6+ variables (laboratory results optional)

Calvert et al., 201655 II R (1) ICU 159 (11.4)
Calvert et al., 201656 II R (1) ICU 270 (0.9)
Desautels et al., 201657 II R (1) ICU 2577 (11.3)
Shimabukuro et al., 201758 IV RCT (1) Dec’17–Feb’18 ICU 22 (32.8)
McCoy et al., 201759 IV BA (1) Nov’16–May’17 ALL 921 (NR)
Calvert et al., 201748 Post NA NA NA
Mao et al., 201836 II R (1) Non-ICU 2142 (2.4)
Burdick et al., 201860 IV BA (1) Jul–Aug’17 ED+ICU 1136 (NR)
Topiwala et al., 201934 V RO (1) Feb–Jun’18 ALL 269 (NR)
Burdick et al., 202061 V BA (9) 2017–mid‘18 Non-ICU 14 166 (22.7)
  • C (Robot Laura)

  • Brazil; MLA = NR

Gonçalves et al., 202035 Post CS (1) Jan–Jun ‘18 NR NR
Scherer et al., 202237 Post RO (1) Mar–Sep ‘20 NR NR
  • D (Sepsis Watch)

  • Duke University.

  •  MLA = recurrent neural network; 86 variables

Futoma et al., 201738 II R (1) ALL 10 552 (21.4)
Futoma et al., 201739 II R (11) ALL 10 552 (21.4)
Bedoya et al., 202040 II R (1) ALL 813 (18.9)
Sendak et al., 202041 III/V CS (3) Apr’16–Nov’18 ALL NA
Sandhu et al., 202042 Post Q (1) Jan–Apr’19 NA NA
Sendak et al., 202043 Post CS (1) NA NA
  • E (TREWScore)

  • Johns Hopkins University. MLA = Cox proportional hazard; 27 features

Henry et al., 201545 II R (1) ICU 2291 (14.1)
Adams et al., 202246 V 2xAC (5) Apr’18–Sep’20 Non-ICU 13 680 (2.3)
Henry et al., 202247 II R (5) Jan’16–Mar’18 Non-ICU 3858 (2.2)
Post PO (5) Apr’18–Mar’20 Non-ICU 9805 (2.1)
Henry et al., 202248 Post Q (1) Oct’18–Apr’19 ALL NA
  • F (Sepsis sniffer)

  • Mayo Clinic.

  •  MLA = decision Tree

Harrison et al., 201549 II R (1) ICU 86 (29)
Lipatov et al., 202250 IV BA (1) Sep’11–May’18 ED + ICU 1096 (9.8)
  • G (ESM)

  • USA, independent. MLA = Log. Reg.

Wong et al., 202151 Post R (1) Dec’18–Oct’19 Unclear 2552 (6.6)
Schootman et al., 202252 Post DiD (15) Jan’16–Jun’19 ALL 6926 (NR)
H USA, independent. MLA = naïve Bayes; 5 features Brown et al., 201653 II R (2) ED 549 (0.4)
Post PO (1) Apr’09–Jun’10 ED 352 (0.4)

Study Designs: R: Retrospective; RO: Retrospective Observational; PO: Prospective Observational; BA: Before-after study; 2xAC: Two-Arm Cohort; RCT: randomized control trial; Q: qualitative study; CS: case study; DiD: difference-in-difference analysis.

a

Stages in the SALIENT framework: I = problem definition; II = retrospective development; III =Silent trial; IV = Pilot trial; V = Large trial/Roll-out; Post= Post deployment study.

b

Outcome definitions are itemized in Supplementary Appendix SF, Table F2.

NA: not applicable; NR: not reported; ED: emergency department; ICU: intensive care unit; ALL: patients from all wards.

Two studies were confined to emergency department settings,32,53 6 involved only intensive care unit (ICU) patients,45,49,55–58 and the remainder involved all wards or non-ICU settings. The prevalence of sepsis varied from as low as 2.1%47 to as high as 22.7% in non-ICU settings,61 and from 11.3%57 to 32.8%58 in ICU settings.

Most studies reported MLA evaluations at stage II (retrospective),32,33,36,38–40,45,48,49,55–57 2 at stage III (silent trial),33,41 4 at stage IV (pilot trial),50,58–60 3 at stage V (large trial/roll-out),33,46,61 and 11 reported post-deployment evaluations.35,37,42–44,47,48,51–53,62

Quality assessment

Eight papers from 5 groups (A, B, E, F, G) were assessed for risk-of-bias (RoB) (see Supplementary Appendix SD). Overall, RoB was serious for 2 groups (A, F), moderate for 2 (E, G) and moderate to critical for one (B). Major sources of bias were potential confounding from additional sepsis control co-interventions, such as staff training in sepsis recognition and management, and other changes in non-sepsis conditions and patient characteristics potentially impacting all-cause mortality at the trial sites. Only 2 trials controlled for these differences in before-after cohorts.46,52

Implementation evaluation

Eighty-five distinct metrics were identified across 26 (87%) papers, grouped into 5 evaluation categories: (1) algorithm performance; (2) algorithm adoption; (3) clinical process effects; (4) patient outcome effects; and (5) financial impact. All metrics reported are listed in Supplementary Appendix SE.

Algorithm performance and adoption

Of 27 performance metrics, sensitivity and positive predictive value were most commonly reported (7 groups, 18 and 9 papers, respectively), closely followed by area under the receiver operating curve (AUROC) and specificity (6 groups, 17 and 13 papers). Most (66%) post-implementation studies did not report real-world MLA performance (Figure 2), and of the 3 that did, one reported improved MLA performance58 while the other 2 showed marked declines,34,50 and similarly for the external validation study of the EPIC tool (Group G).51

Figure 2.

Figure 2.

Evaluation results for algorithm performance, adoption, clinical process, and mortality improvement for each MLA group. Figure includes risk of bias (RoB) assessment for studies reporting mortality assessment (M = moderate [some concerns for RoB-2], S = serious, C = critical). Black numbered squares denote the cited paper for that result. AUC: area under the receiver operating curve; Sens: sensitivity; Spec: specificity; PPV/NPV: positive/negative predictive value. Solid shaded up arrow: significant improvement, whereas hollow up arrow: non-significant improvement.

MLA adoption, measured as the proportion of alerts clinicians responded to, was only reported in Group (E) at 89%, Group (F) at 77%–84% and Group (C) at 100%.

Clinical impact

Of 36 distinct clinical process outcomes reported across 9 papers in 5 groups, the most common were median lead time to first antibiotic use (5 papers, 4 groups), the 3-h sepsis care bundle compliance rate and the increases in antibiotic use (both 3 papers, 3 groups).

Ten different patient outcomes were reported, most commonly mortality and length of hospital stay (LOS) (both 5 groups, 9 papers). All 9 papers34,44,46,50,52,58–61 reported decreased mortality, be that all-cause, sepsis-related or both, although this was statistically significant only for 5 studies: Group (B), both all-cause58 and sepsis-related,59–61 and Group (E), for sepsis-related only,46 both involving a large samples of >13 500 septic patients. Only Group (E) adjusted their findings for differences between cohorts in patient characteristics. Only Group (B) performed more than one independent post-implementation mortality study, with all 5 studies showing improved mortality,58–61 although Topiwala et al34 reported poor post-implementation MLA performance and no significant improvement in mortality.

Of the 2 groups reporting significantly improved sepsis-related mortality, only Group (E) reported strong MLA adoption (89%) and significant decreases in antibiotic lead time.46 Group (B) reported no adoption data and only their smallest study reported improvement in a single process outcome: lead time to antibiotic use.58 Despite group (F) reporting high adoption rates (77% to 84%) and significantly improved rates of sepsis care bundle compliance, post-implementation the MLA specificity dropped markedly, from 96% to 80%, and there was no significant change in all-cause mortality.50

Identification of implementation barriers, enablers, and decision points and mapping to SALIENT AI implementation framework

Barriers, enablers, and decision points provide real-world evidence of factors that are reported by practitioners and can impact MLA implementation success.

Barriers and enablers

We identified 14 unique barriers (Table 2) and 26 unique enablers (Table 3) from a total of 70 mentions across all studies. The most common barriers, identified by at least 3 groups, were lack of clinician trust (B1), alert fatigue (B4) and dismissal of alerts, mainly because clinicians perceived no clinical signs of deterioration (B3). However, 8 barriers were unique to a single group (D), and despite more enablers than barriers, just 2 groups (D, E) provided 80% of the group-level enabler instances.41–43,48 The most commonly reported enabler was frequent communications to raise awareness of the MLA during and after clinical trials (E4), with clinician involvement (E1), improvement cycles (E3), clinical champions (E5), and test versions for training (E6) reported by more than 2 groups. Overall, 90% of all barriers and enablers were AI task agnostic, with just one barrier (B12) and 3 enablers (E2, E11, E26) specific to sepsis prediction.

Table 2.

Implementation barriers

Barriers (stage) Component or element A B C D E F G H Total
B1 Lack of clinician trust (IV+)18 ICA 2 1 1 1 5/4
B2 MLA retraining concerns: Feedback loops arise when alerts lead to timely treatment. (IV+) AI 1 1/1
B3 Alerts dismissed for wrong reasons, for example, patients with no sepsis symptoms or with higher acute complexity (IV+) CW 2 2 1 5/3
B4 Alert fatigue (II+)18 AI; CW; ICA 1 1 1 3/3
B5 Differential nurse/Doctor role, perceptions of role and value (IV+)18 CW; ICA 1 1 2/2
B6 Inherent limitations of EHR data, which can be plagued by missingness, inaccuracies, and changes in practice patterns over time (II+) DP 1 1 2/2
B7 Data entry delays, leading to delayed predictions (III+) DP 1 1/1
B8 Inventors/company equity owners may have COI and inadvertently act in bias ways towards the evaluation of their system (III+) ET 1 1/1
B9 Surveillance bias: important to monitor impact of Alerts on non-septic patients for over-prescription of antibiotics (IV+) ET; EM 1 1/1
B10 Substantial cost involved for infrastructure, implementation personnel time and ongoing maintenance (All)18 ICA; GOV 1 1/1
B11 Lack of individual proficiency of health professionals in the use of hardware and software (IV+) CW; ICA 1 1/1
B12 Clinicians perceive they are better at diagnosing sepsis than the AI and the alert occurs after they already suspect (IV+)18 CW; AI; ICA 1 1 2/2
B13 Lack of machine learning foundational knowledge and firsthand experience (II+)63 CW; ICA 1 1/1
B14 Clinician concern over reliance on system (IV+)63 GOV; QS; ICA 1 1/1
Total papers 8 0 3 9 5 1 0 1 27
Count of barriers identified by the group 6 0 3 9 4 1 0 1 24

For reach barrier, the number of papers that identify the barrier within each group are noted in columns A to H. The totals column is in the format of: total number of papers/total number of groups. The associated element or component in the derived framework is also identified where ICA: Implementation, change management & adoption; AI: AI model; CW: clinical workflow; DP: data pipeline; GOV: governance; QS: Quality & safety; EM: Evaluation and monitoring. Beside each barrier is listed the stage in parentheses, that is associated with that barrier.

Table 3.

Implementation enablers: for reach enabler, the number of papers that identify the enabler within each group are noted in columns A to H

Enablers (stages) Compo-nent A B C D E F G H Tot.
E1 Clinician involvement is essential at all stages of model/HCI development and integration into clinical workflow (II+)18,63 AI; CW, HCI; GOV 2 2 4/2
E2 Better AI model training methods: for negative cases, use portion of patient journey when sick, not within 6h or discharge (II/III) AI 1 1/1
E3 Conduct improvement initiatives (PDSA) cycles during implementation to quickly garner and act on clinical feedback (III+) CW; QS; ICA 1 3/2
E4 Frequent communications to increase awareness during and after trial, for example, weekly meetings, emails, educational sessions giving progress and setting next goals and highlighting urgent need. (IV+)18 ICA 1 1 1 2 5/4
E5 Appoint clinical champions to advocate for the tool (II+) ICA 1 2 3/2
E6 Create a test version of the application to train clinicians and multi-channel training approaches incl. web (III) CW 1 1 2/2
E7 Use a tablet with training loaded, plus feedback mechanism so training could occur on-the-job (IV+) CW 1 1/1
E8 Implement alternative workflows during peak hours (IV+)18 CW 1 1/1
E9 Clinicians were taught how to interpret risk scores (IV+) CW; ET 1 1/1
E10 Iterative approach to design of clinical workflow, human-computer interface and AI model (II+) AI; CW; HCI 1 1/1
E11 Visually delineating sepsis risk into colors (red cards as high risk, etc) and tracking patients across distinct tabs (patients to be triaged, screened out for sepsis, and those in the sepsis bundle) (III) HCI 1 1/1
E12 Perform post-implementation interview (study) to identify improvements (IV+) CW; HCI; QS; ICA 1 1/1
E13 HCI was augmented by completion and fallout indicators to visually guide the clinician to timely and appropriate care (III) CW, HCI 1 1/1
E14 Report the number of cases the AI detects that clinicians miss: clinicians requested this—build trust (IV+) EM; ICA 1 2 3/2
E15 Track and monitor data and model drift (III+) QS; EM 1 1/1
E16 Work with regulatory officials to ensure the solution is qualified as CDS and not a diagnostic medical device (I+) RL 2 2/1
E17 Establish a multi-disciplinary governance committee to promote usage, track compliance, provide training and plan for post-trial sustainability; and an external data safety board to oversee safety and AI efficacy (I+) GOV 1 1/1
E18 A dedicated full-time role can work with frontline clinicians and stakeholders to integrate the tool (IV+) ICA; CW 1 1 2/2
E19 Strong support from senior leadership (I+)18 ICA; GOV 1 1/1
E20 Establish a transdisciplinary team of data scientists, statisticians, hospitalists, intensivists, ED clinicians, RRT nurses, and information technology leaders and develop capabilities across domains (I+) ICA; GOV 1 1/1
E21 Staggered deployment across sites (V+) ICA 1 1/1
E22 Although numbers and statistical trends were used as evidence, individual patient cases were important to frontline clinicians (IV+) ICA 1 1/1
E23 Carefully navigate the lines of professional authority that physicians have toward the care of patients. Tool described as supporting physicians and nurses. The term AI was never used (I+) ICA; ET 2 2/1
E24 Trust in the model increased as the clinician experienced the algorithm make correct predictions (IV+) ICA 1 1/1
E25 A “Model Facts” sheet designed to convey relevant information about the model to clinical end users; (II) ET; AI; ICA 1 1/1
E26 System sepsis monitoring was experienced as alleviating demands on attention and cognition (IV+) ICA 1 1/1
Total papers 0 4 2 23 12 1 0 1 43
Count of group enablers 0 3 2 20 8 1 0 1 35

The totals column is in the format of: total number of papers/total number of groups. The associated components in the SALIENT framework are also identified where ICA: Implementation, change management and adoption; AI: AI model, HCI: human–computer interface, CW: clinical workflow, DP: data pipeline, GOV: governance; ET: Ethics; EM: evaluation and monitoring; RL: Regulatory& legal and QS: Quality & safety. Beside each enabler is listed the stage in parentheses, that is associated with that enabler.

All barriers and enablers could be mapped to the SALIENT AI implantation framework (see Figure 3). All barriers (n = 14) were located between the silent trial stage (III) and the large trial or roll-out stage (V). Most enablers and barriers were identified for the clinical workflow solution component (n = 6 and n = 8, respectively in stages IV and V) and the cross-stage element, ‘Implementation, change management and adoption’ (n = 8 and n = 14, respectively). No barriers were identified that related to the regulatory and legal policy domain or the human computer interface solution component, whereas enablers were identified in all solution components and all cross-stage policy and organizational elements.

Decision points

Twenty-two decision points were identified in our review, with 17 identified by at least 2 groups; all were mapped to the SALIENT implementation framework (Table 4) and depicted in Figure 3.

Table 4.

Decision points identified for each component in the SALIENT framework

Decision Points A B C D E F G H Tot
Definition
D1 Which patients? Age; location: ICU, ED, all non-ICU Identified by differences across papers
D2 What to predict? sepsis, severe, shock? Should you prioritize on mortality? Patients admitted with sepsis and/or hospital acquired sepsis? 1 1 1 3/3
D3 What objective/bundle compliance, early identification, mortality/LOS—primary and secondary outcomes; anti-microbial mis-use (flow on to model) 1 1 1 3/3
D4 What is the minimum expected performance for alarms? precision v sensitivity? 1 1 1 3/3
AI model
D5 Which model: ML vs DL (explainable, earliness of prediction) and where trained 1 2 1 4/3
D6 Which features: simple vs complex, set-in-stone or changeable. Noting this will impact earliest first prediction: immediately at ED or later? 1 3 1 5/3
D7 How early to target alerts? (too early—no symptoms/signs, too late, no clinical utility) 2 1 2 1 1 7/5
D8 What outcome basis for Train/Evaluate? 1 3 1 5/3
Data pipeline
D9 What data access approach to use: direct or separate 2 2/1
D10 Whether inhouse vs external platform/product/solution 2 2/1
D11 What methods of data imputation to use 2 2/1
D12 What level of pipeline sophistication can be supported: model performance vs engineering effort 1 1/1
Clinical workflow
D13 Whether dedicated vs distributed model of alert handling 1 2 1 4/3
D14 What determines the setpoint decision 1 1 2/2
D15 How to deal with ambiguity over alerted patients that have NOT decompensated 2 2 1 5/3
Human–computer interface
D16 Whether integrated with EMR or not and if not—are tablets/phones allowed 3 1 4/2
D17 Whether individual notification (hard alert) or aggregated dashboard (soft alert) 2 2 1 5/3
D18 Which alert timing: suppression of alerts after first alert; one-time or repeat 1 2 3/2
D19 Whether to provide clinician feedback or not
D20 Whether prediction is explained or not 2 1 3 2 8/4
Evaluation and monitoring
D21 Which metrics to use Identified by differences across papers
D22 What process to follow: Silent trial or not and which trial method 1 2 1 4/3
Count of papers 11 9 0 26 16 4 2 4 72
Count of group decisions 8 6 0 14 11 4 2 4 49

The numerals refer to the number of papers by group (A -> H) that discuss a particular decision. The totals column is in the format of: total number of papers/total number of groups.

EHR: electronic health record; ML: machine learning; DL: deep learning; ICU: intensive care unit; ED: emergency department.

Definition decision points (D1-D4)

The target population and care locations were reported by 7 groups (D1); all included the ED, 5 added the ICU or general wards and 4 targeted all areas. No study reported use of different algorithms for the ICU and non-ICU wards, despite ICUs collecting more data elements at higher frequency. Other decisions related to identifying all hospitalized patients with sepsis, including at ED presentation, or only those acquiring it whilst in hospital,38 and whether to identify only patients at higher risk of mortality for prioritized clinical review, thus minimizing clinician workload.46

Twenty-six different definitions of sepsis were used (see Supplementary Appendix SF, Table F2), ranging from sepsis to severe sepsis to septic shock (D2). The prime purpose for implementing sepsis MLAs varied which in turn determined how they were trained and evaluated (D3),43 with evaluation metrics and success criteria varying depending on whether increasing sepsis care bundle compliance,50 providing a sepsis detection and management system,41 reducing anti-microbial overuse52 or decreasing patient mortality and LOS were primary objectives.34,46,58,59,61 The algorithm objective also determined the minimum expected performance for the MLA (D4), in terms of sensitivity (proportion of septic cases detected) and false alarms (proportion of non-septic cases misidentified as sepsis). Different thresholds were chosen according to the anticipated impacts on clinical processes and clinician workload and adoption.60,61

AI model decision points (D5–D8)

We identified 1 statistical AI model (E), 5 ML models (A, B, F, G, H), 1 deep learning (DL) model (E), and 1 unknown (C), with no single model being utilized by more than one group. Selection of model type (D5) varied according to perceived accuracy and adoption based on the level of model explainability,41,45,55 but with trade-offs according to the model’s ability to support time-series data,38,40 accommodate large, high-dimensional datasets,48 and demonstrate better performance.41 Group (D) reported clinicians were willing to sacrifice explainability for more accurate predictions and better standardized treatment of all sepsis cases,41 while Ginestra et al found clinicians most wanted transparency regarding the predictive features generating the alerts.44

Deciding which features to input and how simple (eg, vital signs only) or complex (eg, waveform data and laboratory results) they are was seen to influence model generalizability (D6) to different care locations.38,57,58,62 Group (B) supported different variables for different sites, claiming flexibility,62 although new models needed to be trained, validated and maintained at each site. Another decision was how quickly the MLA needed to make its first prediction after admission (D7), contingent upon the availability of the required data, with potential delays, for example, in obtaining laboratory investigation results.53

Predicting onset of sepsis as early as possible involved trade-offs between: (1) alerts that were too early, where clinicians may not have known what to do, and therefore dismissed the alerts33,41,42,44,47,50,53; and (2) alerts that were too late for patients for whom clinicians already suspected sepsis and had initiated appropriate care bundles (in one study up to half44), thereby diminishing its clinical utility.44,50 The choice also had implications for MLA training and evaluation (D8).

Data pipeline decision points (D9-D12)

Only group (D) contributed to data pipeline decisions for which only 2 barriers (B6, B7) and no enablers were reported. Decisions had to be made (D9) about how to access the data: direct from the Electronic Health Record (EHR), which could entail partnering with the vendor, or indirectly from a real-time data warehouse or various feeder systems.43 Similarly, whether to develop and implement the MLA in-house or use an external vendor (D10), which involved weighing up the capability to future-proof the organization for future AI solutions41 versus implementation and maintenance challenges arising from separate ownership of the input data and the AI model.41 The required level of data pipeline sophistication, including data imputation (D11) and transformation, also necessitated trade-offs between engineering effort versus model performance (D12),41 with group (D) having to remove a data imputation pipeline because of its complexity.40

Clinical workflow decisions (D13-D15)

Whether alerts were to be sent to and managed by dedicated clinical staff (centralized approach) or sent directly to clinicians responsible for individual patient care (distributed approach) varied across studies (D13). Five (A, C, E, F, G) groups chose the former, whereas Sandhu et al found physicians preferred the latter, having a nurse contact them directly, often in-person, rather than by means of EHR-generated alerts which imposed greater cognitive load and interruptions.42 However, the same physicians still saw nurse contacts as disruptive, while nurses found physicians often too busy to contact.42 Having a dedicated clinician receive calls minimized alarm fatigue,41 but group (E) found a distributed approach more scalable for monitoring multiple conditions, more feasible in small-staffed sites, and more able to provoke bedside reviews,48 although clinicians often regarded the numbers of reviews as unmanageable.59

The MLA alert threshold or setpoint determining the numbers of alerts was a key decision impacting clinician workload (D14). Group (E) utilized an improvement cycle to decide on the alert threshold at each local implementation site in improving clinician adoption.47,59

Related to the timing of alerts (D7), decisions about what actions clinicians should take for alerts involving patients showing no symptoms or signs of sepsis proved problematic (D15), as unclear roles and responsibilities constituted potential barriers to adoption (B3, B5).33,44

Human computer interface (HCI) decisions (D16–D20)

How algorithm predictions were presented to clinicians and whether they were accompanied by additional information or even recommendations varied between groups. The HCI options comprised: (1) an alert only (Groups B, H), or with optional attached information (Group A) sent directly to clinicians via messaging systems (phones, e-mails, personal tablets) (D16); (2) content integrated within existing EHRs (Groups E, G); or (3) an external dashboard or application (Groups C, D, F) (D17). Integration into an EHR relied on organisations having a single EHR, otherwise multiple HCIs were required. Also, many EHRs did not have in-built capacity to support complex MLAs,41 whereas external dashboards conferred flexibility to design a bespoke solution that could also support mobile devices,41 although requiring clinicians to switch between applications interrupting workflows.48 The type of alert (D17) varied between hard alerts (such as a pop-up directive) requiring clinicians to immediately respond, and soft alerts (such as colored icons) that were more easily managed.41,42,46,48 No group indicated which method prompted more appropriate clinical actions and conferred better clinical outcomes.50

Whether alerts were allowed to fire once or repeatedly until deactivated (D18) also varied between groups. The EWS2.0 (Group A) used a one-time alert, but found clinician evaluation of patients often occurred some hours after the alert fired.33 Group (F) implemented completion and fall-out indicators for single alerts to visually guide clinicians to more timely review.50 Group (B) supported multiple alerts for the same patient, but incorporated a snooze feature to suppress alerts within 6 h of the first alert.59,61 Whether to include more information about what caused alerts, versus just firing alerts alone (D20) had implications as to how the algorithm was trained. The decision by groups (E, F) to enable clinicians to feedback whether they thought the alert represented sepsis or something else (D19) enabled implementation teams to evaluate clinical utility, and provide feedback to clinicians about missed sepsis cases, which incentivized greater adoption.42,48

Evaluation decisions (D21, D22)

Evaluation decisions (D21) proved challenging as most groups omitted pre- and post-implementation evaluations of MLA performance using the same metrics. If done, it would have enabled linking of MLA performance with changes in clinical care or outcomes (Figure 2). Pre-implementation studies reported AUROC ranging from 0.6351 to 0.9747 but only one post-implementation group (B) study58 reported AUROC of 0.95, which was similar to pre-implementation studies.55,59,60

In regard to pre-deployment silent or shadow trials evaluating algorithm performance against conventional clinical judgment in a live-data environment (D22),33 3 groups (A, D, E) conducted such trials for 6, 3 and an unknown number of months, respectively, during which algorithm validation was undertaken as well as end-to-end testing of the model, the data pipeline, the HCI and the clinical workflow.41,48

DISCUSSION

Systematic review of sepsis MLA implementation studies

The systematic review served to learn how MLA performance, adoption, and different implementation modes were measured and how they impacted clinical care processes and patient outcomes. We found MLAs have potential to reduce mortality, but no definitive causal relationship has been demonstrated. At a minimum, the causal chain requires a high performing (high sensitivity/low false alarm) implemented MLA, clinician adoption and resulting positive changes to clinical processes (see Figure 2). Two groups (B, E) could demonstrate at least 2 of these, together with a significant reduction in mortality but only Group E reported definitive evidence of MLA adoption.

Demonstrating a causal link was limited by: (1) Non-randomized study designs being subject to confounding bias, such as sepsis awareness programs accompanying MLA implementation; and (2) Infrequently reported and non-standardized MLA performance metrics post-implementation, which, when they were reported, often showed decreased accuracy. Given these limitations, it remains unclear whether MLAs were responsible or needed for improved mortality. In a meta-review of 55 observational studies of sepsis reduction programs using guideline-based care bundles,64 a significant 34% overall reduction in mortality was achieved despite the absence of digitally embedded sepsis screening or alert tools in most studies (43/55, 78%).

Other important study findings were, firstly, clinical process improvements after MLA implementation did not always result in better patient outcomes, likely due to different clinical process improvement metrics (N = 36). However, significant reductions in just one metric, median lead time from alert to first antibiotic, did coincide with significant reductions in mortality,46,47,58 suggesting this as an important indicator of MLA implementation success.

Second, it remains unclear whether MLA model choice impacts implementation success. Seven different algorithms were implemented with 5 reporting improved clinical indicators and mortality outcomes. The level of MLA performance post-implementation appears to be more important than choice of algorithm in predicting effectiveness. Across 2 different MLAs (Groups B and F), only the algorithm with high post-implementation performance was associated with significant mortality improvement.50,58 Similar results were seen for 2 independent implementations of the same algorithm (Group B).34,58

Third, the choice of outcome definition, in this case sepsis, is critical as it can directly influence algorithm performance measures, particularly specificity.6 Definitions of sepsis varied from initial systemic inflammatory process (eg, Sepsis-1 definition)3 to multi-organ dysfunction (eg, Sepsis-3 definition)65 reflecting a later, more advanced state of the illness. Importantly, the concern here is diagnosing sepsis (ie, using a diagnostic predictive algorithm) rather than predicting the likelihood of sepsis occurring in a patient before the inflammatory process begins (ie, a prognostic predictive algorithm).66

Fourth, how algorithm predictions are presented to clinicians, and the extent to which they are accompanied by additional information or even recommendations are key determinants of clinician acceptance.67

Mapping to SALIENT AI implementation framework

The second study objective was to map the review findings to the SALIENT framework to validate its coverage of important real-world implementation factors. Unlike in similar reviews,6–8,11,17,68,69 we conducted a novel 2-stage review wherein the second stage we identified related studies before or after the principal deployment study, which provided studies across the end-to-end MLA implementation process. We found the findings of each study could be mapped to one or more stages within SALIENT and that all SALIENT stages were utilized across all studies, indicating that SALIENT’s implementation stages are both necessary and sufficient for real-world sepsis MLA implementation.

Secondly, every barrier, enabler, and decision identified in the review could be located to a stage (I-V) and either components (AI model, data pipeline, clinical workflow, HCI) or elements (A–G) within SALIENT. Knowing in advance what decisions are required (for example as a checklist), when they need to be made and in relation to which part of the implementation process is novel and could be informative to those engaged in AI implementation planning. We also found that most of the decision points, barriers and enablers identified were not specific to sepsis prediction, but were AI-task agnostic, suggesting SALIENT may have application for non-sepsis MLA implementation projects.

Strengths and limitations

As far as we know, our study is the first attempt to undertake a systematic review of sepsis prediction algorithms deployed in clinical settings, to identify barriers, enablers, and key decision points, and to map these to a single, inclusive, end-to-end implementation framework. The resulting framework and mapped items render these key decisions and contextual factors explicit, ordered and transparent, address gaps in current implementation guidance and offers a pragmatic staged approach for use by clinicians, informatics personnel and managers. Limitations relate to the small number of empirical studies of deployed sepsis-prediction algorithms, under-reporting of post-implementation performance metrics, focus on adult hospital settings, and potential publication bias from under-reporting of other sepsis MLA implementation studies.18 Although risk of bias for mortality reporting studies was moderate to high, all studies, including the 3 lowest bias papers,46,52,58 reported numerical reductions in mortality, with 5 being significant.46,58–61

CONCLUSIONS

Our systematic review indicates that implementing MLAs within adult hospital care settings to predict sepsis has potential to reduce mortality, but no definitive causal link has been demonstrated. Implemented MLAs were few and only 2 provided some evidence of causation. The types of MLA models employed mattered less than their implementation accuracies and ability to alert clinicians to order antibiotics earlier.

This study also validated the SALIENT framework demonstrating real-world MLA implementation barriers, enablers, and decisions could be mapped to its constituent stages and components. Our findings highlight that AI implementation success has many more dimensions than the types of MLA employed, including evaluation methods and stages and the many decisions required throughout the multi-stage process. SALIENT may provide a roadmap for stakeholders to identify these stages, components and decisions which, with more robust studies, may be shown to conclusively link MLA implementation with significant improvement in patient outcomes. The SALIENT framework also has potential application to other MLA algorithms seeking to identify patients at risk of other acute hospital acquired conditions.

Supplementary Material

ocad075_Supplementary_Data

ACKNOWLEDGMENTS

External review was conducted with thanks by Dr. Amith Shetty, Clinical Director at the NSW Ministry of Health.

Contributor Information

Anton H van der Vegt, Queensland Digital Health Centre, The University of Queensland, Brisbane, Queensland, Australia.

Ian A Scott, Department of Internal Medicine and Clinical Epidemiology, Princess Alexandra Hospital, Brisbane, Australia.

Krishna Dermawan, Centre for Information Resilience, The University of Queensland, St Lucia, Australia.

Rudolf J Schnetler, School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Australia.

Vikrant R Kalke, Patient Safety and Quality, Clinical Excellence Queensland, Queensland Health, Brisbane, Australia.

Paul J Lane, Safety Quality & Innovation, The Prince Charles Hospital, Queensland Health, Brisbane, Australia.

FUNDING

AHvdV was funded through a Queensland Government, Advanced Queensland Industry Research Fellowship grant. The Queensland Government had no role within this research.

AUTHOR CONTRIBUTIONS

AHvdV and IAS conceptualized the review. AHvdV, KD, and RJS conducted the title/abstract screening and full text review. VRK, RJS, and AHvdV performed the risk-of-bias assessments. AHvdV and KD performed all data extraction and tabular data collation. AHvdV derived the proposed framework. AHvdV, IAS, and KD drafted the manuscript with revisions and feedback from PJL, VRK, and RJS.

SUPPLEMENTARY MATERIAL

Supplementary material is available at Journal of the American Medical Informatics Association online.

CONFLICT OF INTEREST STATEMENT

The authors declare no competing interests with respect to this publication.

DATA AVAILABILITY

There are no new data associated with this article.

REFERENCES

  • 1. Rudd KE, Johnson SC, Agesa KM, et al. Global, regional, and national sepsis incidence and mortality, 1990–2017: analysis for the Global Burden of Disease Study. Lancet 2020; 395 (10219): 200–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Fernando SM, Rochwerg B, Seely AJE.. Clinical implications of the third international consensus definitions for sepsis and septic shock (Sepsis-3). CMAJ 2018; 190 (36): E1058–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Bone RC, Balk RA, Cerra FB, et al. Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Chest 1992; 101 (6): 1644–55. [DOI] [PubMed] [Google Scholar]
  • 4. Dugani S, Veillard J, Kissoon N.. Reducing the global burden of sepsis. CMAJ 2017; 189 (1): E2–3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Seymour CW, Gesten F, Prescott HC, et al. Time to treatment and mortality during mandated emergency care for sepsis. N Engl J Med 2017; 376 (23): 2235–44. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Hassan N, Slight R, Weiand D, et al. Preventing sepsis; how can artificial intelligence inform the clinical decision-making process? A systematic review. Int J Med Inform 2021; 150: 104457. [DOI] [PubMed] [Google Scholar]
  • 7. Ackermann K, Baker J, Green M, et al. Computerized clinical decision support systems for the early detection of sepsis among adult inpatients: scoping review. J Med Internet Res 2022; 24 (2): e31083. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Wulff A, Montag S, Marschollek M, Jack T.. Clinical decision-support systems for detection of systemic inflammatory response syndrome, sepsis, and septic shock in critically ill patients: a systematic review. Methods Inf Med 2019; 58 (S 02): E43–57. [DOI] [PubMed] [Google Scholar]
  • 9. Schinkel M, Paranjape K, Nannan Panday RS, Skyttberg N, Nanayakkara PWB.. Clinical applications of artificial intelligence in sepsis: a narrative review. Comput Biol Med 2019; 115: 103488. [DOI] [PubMed] [Google Scholar]
  • 10. Islam MM, Nasrin T, Walther BA, Wu CC, Yang HC, Li YC.. Prediction of sepsis patients using machine learning approach: a meta-analysis. Comput Methods Programs Biomed 2019; 170: 1–9. [DOI] [PubMed] [Google Scholar]
  • 11. Fleuren LM, Klausch TLT, Zwager CL, et al. Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy. Intensive Care Med 2020; 46 (3): 383–400. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Stead WW, Haynes RB, Fuller S, et al. Designing medical informatics resource projects to increase what is learned. J Am Med Inform Assoc 1994; 1 (1): 28–33. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13. Greenhalgh T, Wherton J, Papoutsi C, et al. Beyond adoption: a new framework for theorizing and evaluating nonadoption, abandonment, and challenges to the scale-up, spread, and sustainability of health and care technologies. J Med Internet Res 2017; 19 (11): e367. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Reddy S, Rogers W, Makinen VP, et al. Evaluation framework to guide implementation of AI systems into healthcare settings. BMJ Health Care Inform 2021; 28 (1): 1–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Gama F, Tyskbo D, Nygren J, Barlow J, Reed J, Svedberg P.. Implementation frameworks for artificial intelligence translation into health care practice: scoping review. J Med Internet Res 2022; 24 (1): e32215. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Bakken S, Ruland CM.. Translating clinical informatics interventions into routine clinical care: how can the RE-AIM framework help? J Am Med Inform Assoc 2009; 16 (6): 889–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Moor M, Rieck B, Horn M, Jutzeler CR, Borgwardt K.. Early prediction of sepsis in the ICU using machine learning: a systematic review. Front Med (Lausanne)2021; 8: 607952. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Joshi M, Mecklai K, Rozenblum R, Samal L.. Implementation approaches and barriers for rule-based and machine learning-based sepsis risk prediction tools: a qualitative study. JAMIA Open 2022; 5 (2): 1–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Schwartz JM, George M, Rossetti SC, et al. Factors influencing clinician trust in predictive clinical decision support systems for in-hospital deterioration: qualitative descriptive study. JMIR Hum Factors 2022; 9 (2): e33960. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Sendak M, Gao M, Nichols M, Lin A, Balu S.. Machine learning in health care: a critical appraisal of challenges and opportunities. EGEMS (Wash DC) 2019; 7 (1): 1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. van der Vegt A, Scott I, Dermawan K, Schnetler R, Kalke V, Lane P. Implementation frameworks for end-to-end clinical AI: derivation of the SALIENT framework. 2023. Manuscript submitted for publication. [DOI] [PMC free article] [PubMed]
  • 22. Vasey B, Nagendran M, Campbell B, et al. Reporting guideline for the early stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI. BMJ 2022; 377: e070904. doi: 10.1136/BMJ-2022-070904. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Damschroder LJ, Aron DC, Keith RE, Kirsh SR, Alexander JA, Lowery JC.. Fostering implementation of health services research findings into practice: a consolidated framework for advancing implementation science. Implement Sci2009; 4: 50. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Reed JE, Howe C, Doyle C, Bell D.. Successful Healthcare Improvements From Translating Evidence in complex systems (SHIFT-Evidence): simple rules to guide practice and research. Int J Qual Health Care 2019; 31 (3): 238–44. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25. Collins GS, Reitsma JB, Altman DG, Moons KGM.. Transparent reporting of a multivariable prediction model for individual prognosis or diagnosis (TRIPOD): the TRIPOD statement. Eur J Clin Invest 2015; 45 (2): 204–14. [DOI] [PubMed] [Google Scholar]
  • 26. Moons KGM, Altman DG, Reitsma JB, et al. Transparent reporting of a multivariable prediction model for individual prognosis or diagnosis (TRIPOD): explanation and elaboration. Ann Intern Med 2015; 162 (1): W1–73. [DOI] [PubMed] [Google Scholar]
  • 27. Liu X, Rivera SC, Moher D, Calvert MJ, Denniston AK; SPIRIT-AI and CONSORT-AI Working Group. Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: the CONSORT-AI extension. BMJ 2020; 370: m3164. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Moher D, Shamseer L, Clarke M, et al. ; PRISMA-P Group. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev 2015; 4 (1): 1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Veritas Health Innovation. Covidence. 2022. www.covidence.org. Accessed August 4, 2022.
  • 30. Sterne JA, Hernán MA, Reeves BC, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ 2016; 355: i4919. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31. Sterne JAC, Savović J, Page MJ, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 2019; 366: l4898. [DOI] [PubMed] [Google Scholar]
  • 32. Taylor RA, Pare JR, Venkatesh AK, et al. Prediction of in-hospital mortality in emergency department patients with sepsis: a local big data-driven, machine learning approach. Acad Emerg Med 2016; 23 (3): 269–78. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33. Giannini HM, Ginestra JC, Chivers C, et al. A machine learning algorithm to predict severe sepsis and septic shock: development, implementation, and impact on clinical practice. Crit Care Med 2019; 47 (11): 1485–92. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34. Topiwala R, Patel K, Twigg J, Rhule J, Meisenberg B.. Retrospective observational study of the clinical performance characteristics of a machine learning approach to early sepsis identification. Crit Care Explor 2019; 1 (9): e0046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35. Gonçalves LS, de Amaro ML, de Romero M, et al. Implementation of an artificial intelligence algorithm for sepsis detection. Rev Bras Enferm 2020; 73 (3): e20180421. [DOI] [PubMed] [Google Scholar]
  • 36. Mao Q, Jay M, Hoffman JL, et al. Multicentre validation of a sepsis prediction algorithm using only vital sign data in the emergency department, general ward and ICU. BMJ Open 2018; 8 (1): e017833. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Scherer J de S, Pereira JS, Debastiani MS, Bica CG.. Beyond technology: can artificial intelligence support clinical decisions in the prediction of sepsis? Rev Bras Enferm 2022; 75 (5): e20210586. [DOI] [PubMed] [Google Scholar]
  • 38. Futoma J, Hariharan S, Heller K. Learning to detect sepsis with a multitask Gaussian process RNN classifier. In: 34th International Conference on Machine Learning, ICML 2017. Vol 3; Sydney; 2017:1914–1922.
  • 39. Futoma J, Hariharan S, Sendak M, et al. An improved multi-output Gaussian process RNN with real-time validation for early sepsis detection. Proc Mach Learn Healthc 2017; 68: 2017. http://arxiv.org/abs/1708.05894. [Google Scholar]
  • 40. Bedoya AD, Futoma J, Clement ME, et al. Machine learning for early detection of sepsis: an internal and temporal validation study. JAMIA Open 2020; 3 (2): 252–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41. Sendak MP, Ratliff W, Sarro D, et al. Real-world integration of a sepsis deep learning technology into routine clinical care: implementation study. JMIR Med Inform 2020; 8 (7): e15182. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42. Sandhu S, Lin AL, Brajer N, et al. Integrating a machine learning system into clinical workflows: qualitative study. J Med Internet Res 2020; 22 (11): e22421. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43. Sendak M, Elish MC, Gao M, et al. “The human body is a black box”: supporting clinical decision-making with deep learning. In: FAT 2020—Proceedings of the 2020 Conference on Fairness, Accountability, and Transparency. 2020:99–109. doi: 10.1145/3351095.3372827. [DOI]
  • 44. Ginestra JC, Giannini HM, Schweickert WD, et al. Clinician perception of a machine learning–based early warning system designed to predict severe sepsis and septic shock. Crit Care Med 2019; 47 (11): 1477–84. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45. Henry KE, Hager DN, Pronovost PJ, Saria S.. A targeted real-time early warning score (TREWScore) for septic shock. Sci Transl Med 2015; 7 (299): 299ra122-299ra122. doi: 10.1126/SCITRANSLMED.AAB3719/SUPPL_FILE/7-299RA122_SM.PDF. [DOI] [PubMed] [Google Scholar]
  • 46. Adams R, Henry KE, Sridharan A, et al. Prospective, multi-site study of patient outcomes after implementation of the TREWS machine learning-based early warning system for sepsis. Nat Med 2022; 28 (7): 1455–60. [DOI] [PubMed] [Google Scholar]
  • 47. Henry KE, Kornfield R, Sridharan A, et al. Human-machine teaming is key to AI adoption: clinicians’ experiences with a deployed machine learning system. NPJ Digit Med 2022; 5 (1): 97. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48. Henry KE, Adams R, Parent C, et al. Factors driving provider adoption of the TREWS machine learning-based early warning system and its effects on sepsis treatment timing. Nat Med 2022; 28 (7): 1447–54. [DOI] [PubMed] [Google Scholar]
  • 49. Harrison AM, Thongprayoon C, Kashyap R, et al. Developing the surveillance algorithm for detection of failure to recognize and treat severe sepsis. Mayo Clin Proc 2015; 90 (2): 166–75. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50. Lipatov K, Daniels CE, Park JG, et al. Implementation and evaluation of sepsis surveillance and decision support in medical ICU and emergency department. Am J Emerg Med 2022; 51: 378–83. [DOI] [PubMed] [Google Scholar]
  • 51. Wong A, Otles E, Donnelly JP, et al. External validation of a widely implemented proprietary sepsis prediction model in hospitalized patients. JAMA Intern Med 2021; 181 (8): 1065–70. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52. Schootman M, Wiskow C, Loux T, et al. Evaluation of the effectiveness of an automated sepsis predictive tool on patient outcomes. J Crit Care 2022; 71: 154061. [DOI] [PubMed] [Google Scholar]
  • 53. Brown SM, Jones J, Kuttler KG, Keddington RK, Allen TL, Haug P.. Prospective evaluation of an automated method to identify patients with severe sepsis or septic shock in the emergency department. BMC Emerg Med2016; 16 (1): 31. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54. Burdick H, Pino E, Gabel-Comeau D, et al. Validation of a machine learning algorithm for early severe sepsis prediction: a retrospective study predicting severe sepsis up to 48 h in advance using a diverse dataset from 461 US hospitals. BMC Med Inform Decis Mak 2020; 20 (1): 1–10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55. Calvert JS, Price DA, Chettipally UK, et al. A computational approach to early sepsis detection. Comput Biol Med 2016; 74: 69–73. [DOI] [PubMed] [Google Scholar]
  • 56. Calvert J, Desautels T, Chettipally U, et al. High-performance detection and early prediction of septic shock for alcohol-use disorder patients. Ann Med Surg (Lond) 2016; 8 (2016): 50–5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57. Desautels T, Calvert J, Hoffman J, et al. Prediction of sepsis in the intensive care unit with minimal electronic health record data: a machine learning approach. JMIR Med Inform 2016; 4 (3): e28. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58. Shimabukuro DW, Barton CW, Feldman MD, Mataraso SJ, Das R.. Effect of a machine learning-based severe sepsis prediction algorithm on patient survival and hospital length of stay: a randomised clinical trial. BMJ Open Resp Res 2017; 4 (1): e000234. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59. McCoy A, Das R.. Reducing patient mortality, length of stay and readmissions through machine learning-based sepsis prediction in the emergency department, intensive care unit and hospital floor units. BMJ Open Qual 2017; 6 (2): e000158. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60. Burdick H, Pino E, Gabel-Comeau D, et al. Evaluating a sepsis prediction machine learning algorithm in the emergency department and intensive care unit: a before and after comparative study. bioRxiv 2018; (872): 224014. [Google Scholar]
  • 61. Burdick H, Pino E, Gabel-Comeau D, et al. Effect of a sepsis prediction algorithm on patient mortality, length of stay and readmission: a prospective multicentre clinical outcomes evaluation of real-world patient data from US hospitals. BMJ Heal Care Informatics 2020; 27 (1): 1–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62. Calvert J, Hoffman J, Barton C, et al. Cost and mortality impact of an algorithm-driven sepsis prediction system. J Med Econ 2017; 20 (6): 646–51. [DOI] [PubMed] [Google Scholar]
  • 63. Stead WW. Clinical implications and challenges of artificial intelligence and deep learning. JAMA - J Am Med Assoc 2018; 320 (11): 1107–8. [DOI] [PubMed] [Google Scholar]
  • 64. Damiani E, Donati A, Serafini G, et al. Effect of performance improvement programs on compliance with sepsis bundles and mortality: a systematic review and meta-analysis of observational studies. PLoS One 2015; 10 (5): e0125827. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65. Seymour CW, Liu VX, Iwashyna TJ, et al. Assessment of clinical criteria for sepsis for the third international consensus definitions for sepsis and septic shock (sepsis-3). JAMA - J Am Med Assoc 2016; 315 (8): 762–74. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66. Faisal M, Scally A, Richardson D, et al. Development and external validation of an automated computer-aided risk score for predicting sepsis in emergency medical admissions using the patient’s first electronically recorded vital signs and blood test results. Crit Care Med 2018; 46 (4): 612–8. [DOI] [PubMed] [Google Scholar]
  • 67. Kennedy G, Gallego B.. Clinical prediction rules: a systematic review of healthcare provider opinions and preferences. Int J Med Inform 2019; 123 (November 2017): 1–10. [DOI] [PubMed] [Google Scholar]
  • 68. Lee J, Yoon W, Kim S, et al. BioBERT: a pre-trained biomedical language representation model for biomedical text mining. Bioinformatics 2020; 36 (4): 1234–40. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 69. Yin J, Ngiam KY, Teo HH.. Role of artificial intelligence applications in real-life clinical practice: systematic review. J Med Internet Res 2021; 23 (4): e25759. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

ocad075_Supplementary_Data

Data Availability Statement

There are no new data associated with this article.


Articles from Journal of the American Medical Informatics Association : JAMIA are provided here courtesy of Oxford University Press

RESOURCES