Abstract
A thin PVC film was used as a diffusion filter together with glass lenses in order to induce a unilateral artificial contrast sensitivity depression in controls. These artificially depressed contrast sensitivity functions were made comparable to those assessed in patients during the recovery phase of their acute unilateral optic neuritis. A technique of subjective suprathreshold contrast matching was used to determine the suprathreshold apparent contrast in patients and controls with acute and simulated optic neuritis respectively. The results showed that differences in apparent contrast between the eyes is proportional to the discrepancy in threshold contrast for high and intermediate spatial frequencies in patients with optic neuritis. For low frequencies the apparent contrast difference was independent of threshold differences. Contrast vision of controls with simulated optic neuritis did not show this frequency dependency. There was also a discrepancy in visual acuity between the two groups. Generally the control with artificially depressed contrast sensitivity functions has a letter acuity value lower than that of the optic neuritis patient with a corresponding CSF depression.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Georgeson M. A., Sullivan G. D. Contrast constancy: deblurring in human vision by spatial frequency channels. J Physiol. 1975 Nov;252(3):627–656. doi: 10.1113/jphysiol.1975.sp011162. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hess R. F., Bradley A. Contrast perception above threshold is only minimally impaired in human amblyopia. Nature. 1980 Oct 2;287(5781):463–464. doi: 10.1038/287463a0. [DOI] [PubMed] [Google Scholar]
- Hess R. F., Bradley A., Piotrowski L. Contrast-coding in amblyopia. I. Differences in the neural basis of human amblyopia. Proc R Soc Lond B Biol Sci. 1983 Feb 22;217(1208):309–330. doi: 10.1098/rspb.1983.0012. [DOI] [PubMed] [Google Scholar]
- Hess R. F. Contrast vision and optic neuritis: neural blurring. J Neurol Neurosurg Psychiatry. 1983 Nov;46(11):1023–1030. doi: 10.1136/jnnp.46.11.1023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hess R. F. Contrast-coding in amblyopia. II. On the physiological basis of contrast recruitment. Proc R Soc Lond B Biol Sci. 1983 Feb 22;217(1208):331–340. doi: 10.1098/rspb.1983.0013. [DOI] [PubMed] [Google Scholar]
- Kulikowski J. J. Effective contrast constancy and linearity of contrast sensation. Vision Res. 1976;16(12):1419–1431. doi: 10.1016/0042-6989(76)90161-9. [DOI] [PubMed] [Google Scholar]
- Sjöstrand J., Abrahamsson M. Suprathreshold vision in acute optic neuritis. J Neurol Neurosurg Psychiatry. 1982 Mar;45(3):227–234. doi: 10.1136/jnnp.45.3.227. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sjöstrand J. Contrast sensitivity in macular disease using a small-field and a large-field TV-system. Acta Ophthalmol (Copenh) 1979 Oct;57(5):832–846. doi: 10.1111/j.1755-3768.1979.tb01851.x. [DOI] [PubMed] [Google Scholar]
- Swanson W. H., Wilson H. R., Giese S. C. Contrast matching data predicted from contrast increment thresholds. Vision Res. 1984;24(1):63–75. doi: 10.1016/0042-6989(84)90145-7. [DOI] [PubMed] [Google Scholar]
