Skip to main content
Membranes logoLink to Membranes
. 2023 May 29;13(6):557. doi: 10.3390/membranes13060557

Modeling and Optimal Operating Conditions of Hollow Fiber Membrane for CO2/CH4 Separation

Dheyaa J Jasim 1,2, Thamer J Mohammed 3, Hamed N Harharah 4, Ramzi H Harharah 4,*, Abdelfattah Amari 4,5, Mohammed F Abid 6
Editors: Juan D Gil, Juan Antonio Andrés-Mañas
PMCID: PMC10302311  PMID: 37367761

Abstract

In this work, the capture of carbon dioxide using a dense hollow fiber membrane was studied experimentally and theoretically. The factors affecting the flux and recovery of carbon dioxide were studied using a lab-scale system. Experiments were conducted using a mixture of methane and carbon dioxide to simulate natural gas. The effect of changing the CO2 concentration from 2 to 10 mol%, the feed pressure from 2.5 to 7.5 bar, and the feed temperature from 20 to 40 °C, was investigated. Depending on the solution diffusion mechanism, coupled with the Dual sorption model, a comprehensive model was implemented to predict the CO2 flux through the membrane, based on resistance in the series model. Subsequently, a 2D axisymmetric model of a multilayer HFM was proposed to simulate the axial and radial diffusion of carbon dioxide in a membrane. In the three domains of fiber, the CFD technique was used to solve the equations for the transfer of momentum and mass transfer by using the COMSOL 5.6. Modeling results were validated with 27 experiments, and there was a good agreement between the simulation results and the experimental data. The experimental results show the effect of operational factors, such as the fact that temperature was directly on both gas diffusivity and mass transfer coefficient. Meanwhile, the effect of pressure was exactly the opposite, and the concentration of CO2 had almost no effect on both the diffusivity and the mass transfer coefficient. In addition, the CO2 recovery changed from 9% at a pressure equal to 2.5 bar, temperature equal to 20 °C, and a concentration of CO2 equal to 2 mol%, to 30.3% at a pressure equal to 7.5 bar, temperature equal to 30 °C, and concentration of CO2 equal 10 mol%; these conditions are the optimal operating point. The results also manifested that the operational factors that directly affect the flux are pressure and CO2 concentration, while there was no clear effect of temperature. This modeling offers valuable data about the feasibility studies and economic evaluation of a gas separation unit operation as a helpful unit in the industry.

Keywords: CO2 capture, asymmetric HFM, flux, glassy polymer, COMSOL

1. Introduction

Solvent absorption, cryogenic fractionation, and adsorption are the traditional methods for separating and purification of gas mixtures. Equipment complexity, energy consumption, and high capital costs do not prevent them from being mature and reliable methods. Therefore, the membrane separation method represents a promising solution for the scientific and industrial community due to low capital costs, ease of design and operation, low operating and maintenance costs, low energy consumption, and the absence of environmental damage [1,2].

The global market for gas separation membranes was estimated at USD 897 million in the year 2022, and is projected to reach a revised size of USD 1.1 billion by 2026 [2]. The porous and non-porous membranes are utilized to detach CO2 from natural gas; however, in large-scale applications, all the membranes depend on a high-density polymer membrane. The techniques of gas isolation in this type of membrane rely on a solution-diffusion mechanism [3,4].

Some standards mostly impact the selection of the membrane when utilized for a particular implementation, such as mechanical efficacy at the operative parameters, stability, yield, separation effectiveness, et cetera. Four fundamentals should be accurately tested for the membrane Gas Separation operation:

  • -

    The material (permeability and separation factors).

  • -

    The membrane structure and thickness (permeance).

  • -

    The membrane configuration (e.g., flat and hollow fiber).

Both membrane’s permeability and selectivity influence the economics of a Gas Separation membrane process. Selectivity is a main factor in achieving both high output purity and yield [5,6].

1.1. Material and Construction of Gas Membrane

According to the properties of the material, membranes are distributed into polymeric, inorganic, and metallic membranes. Moreover, polymeric membranes have a main part in commercial applications for their distinct economy and competing efficiency. Polymeric membrane substances can be categorized into glassy and rubbery polymers [6]. Polycarbonates (PC), polyimide (PI), polyethersulfone (PESf), Polysulfone (PSF), and cellulose acetate (CA) are popular polymeric membranes. Polysulfone (PSF) is one of the exceedingly examined polymer membrane substances. It is in general utilized to divide gas because of its cheap cost, chemical stability, good strength, high durability to plasticization, and reasonable gas selectivity [7,8].

Polymeric membranes, mostly used for gas segregation, are in general asymmetric or composite and rely on a gas-solution diffusion mechanism. These membranes, manufactured as plane sheets or hollow fibers, have a slim, high-density coat on the microporous prop that affords mechanical vigor. Usually, polymeric membranes give high selectivity compared to porous inorganic substances due to their low free space. Their permeability and selectivity are in negative relation; as permeability is increased, selectivity is decreased, and vice versa. Nowadays, only about nine polymer substances are used for the manufacturing of about 85% of commercially made membranes [9,10].

1.2. Membrane Configuration

There are three different models of membranes commonly used in the industrial field, the plate and frame module, spiral wound module, and hollow fiber module. The preference between the three sets counts on the following requests being performed:

  • -

    High firmness density.

  • -

    Reasonable distribution of fluid.

  • -

    Good stability of mechanical, thermal, and chemical properties.

  • -

    Low-pressure difference.

  • -

    Low-cost fabrication.

  • -

    Simplicity in maintenance and running.

  • -

    The potency of membrane change.

  • -

    The potential of changing the system size.

  • -

    The potency of decontamination.

However, as the decontamination capacity is of less significance in gas segregation the major concern of module layout is a good packing density [11,12,13,14]. A hollow fiber module of 0.04 m3 can accommodate an active surface area of 575 m2, while the same volume of a spiral wound design can only accommodate 30 m2 [15].

Asymmetric hollow fibers have tubular shapes and show rising fluxes required for productive segregations due to the ability to reduce the segregation layer to a thin skin on the exterior surface of the membrane [16,17]. Due to the cheap cost, dense material, and high ratio of surface area to volume, hollow fiber membranes are largely used in gas segregation implementations. Additionally, the asymmetric structure of the hollow fibers shows good mechanical strength and reduces the membrane resistance against the transfer of the components [18,19].

The main objective of this study is represented by three steps. The first step included a proposal for a mathematical model based on the resistance in series to mass transfer. In the second step, the effect of operational factors on the diffusivity and mass transfer coefficient on both sides of the membrane, as well as gas solubility, gas permeability, and selectivity for the membrane material, was investigated. Finally, the experiment results were simulated using the CFD model and compared with the mathematical model, and the effect of operational factors on the recovery and flow of carbon dioxide through the membrane was studied.

2. Theory and Mathematical Model

Three sub-models are needed to accomplish the characterization of the HFM (Hollow Fiber Membrane) model: two sub-models depict the flow on each side of the membrane, and the third identifies the segregation technique in the membrane and any pored backing material [16]. A mathematical model of CO2 captured from a gas mixture using asymmetric HFM was developed by resistance in a series approach for the three domains of the membrane. Figure 1 displays the concentration profiles of CO2 on both sides of the membrane, including the effect of the three resistances on the mass transfer. Carbon dioxide transfer across the membrane is governed by Fick’s law in the gas–membrane interfaces, and the thermodynamic equilibrium is existing. In the law of Fick’s, the concentration of carbon dioxide on the surface of the membrane is related to the partial pressure of this gas and is governed by the dual-mode theory.

Figure 1.

Figure 1

Concentration and partial profiles of CO2 transport through the nonporous membrane.

At a steady-state process, the rate of mass transfer of piercing components, i, across the three resistances is as coming after, by suggesting no variation in the area for mass transfer through the membrane:

Ni=kiFCi,FCi,m1, (1)
Ni=SiDMilMCi,m1Ci,m2, (2)
Ni=kiPCi,m2CiP. (3)

After combining the three equations to eliminate the intermediate concentration, Ci,m1 and Ci,m2 (kmol/m3), the equation becomes as follows [18]:

Ni=CiFCiP1kiF+lMSiDMi+1kiP, (4)

where Ni is the molar transmembrane flux of species i (kmol/s-m2), CiF and CiP are concentration on the feed and permeate, respectively (kmol/m3), DMi is the diffusivity of the solute in the membrane (m2/s), Si is the solute solubility in the membrane [m3(gas)/m3 (membrane)], lM is the thickness of the membrane (m), and kiF, kiP are the mass transfer coefficient on the feed and permeate, respectively (m/s).

2.1. Physical Properties of the Gas Mixture

The flux of carbon dioxide through the regions of the membrane is calculated from Equation (4), and solving this equation requires many inputs, such as viscosity and diffusivity. For gas mixtures, the dynamic viscosity is calculated according to the semiempirical equation with the following expression [20,21,22]:

μmix=i=1nμixij=1nxjij, (5)

where, ij is defined as:

ij=180.51+MiMj0.51+μiμj0.5MiMj0.252, (6)

In Equations (5) and (6), n is the number of species in the mixture, and xi and xj are the mole fractions of species i and j, respectively. Where Mi and Mj are the molecular weight of species i and j, respectively (kg/mol), and μi and μj are the viscosity of pure gases i and j.

2.2. Gas Diffusivity in the Membrane Regions

The diffusivity in the tube and permeate sides are calculated in terms of binary diffusion coefficients from the Chapman–Enskog Equation [22]:

Dij=1.8583×1027T31Mi+1MjPfσij2ΩD1, (7)

In Equation (7), σ represents the collision diameter of the components, and ΩD1 is the dimensionless collision integral. In the region of the membrane, the solution-diffusion model is the most widely used transport model for permeation in the polymer membrane. In this mechanism, the gas dissolves in the membrane material and diffuses as a result of the pressure difference on both sides. The separation is achieved between different gases because of the differences in the amount of gas that sorbs and dissolves in the membrane and the rate at which the gas diffuses through the membrane [20].

The sorption step in the glass polymer used here is completely different from the rubbery polymer and cannot be described by the conventional model. Specifically, the NELF model is used to estimate the sorption in glass Polymer membranes [23,24].

Essentially, gas molecules penetrate through the voids in the polymeric chains, causing the gas to diffuse across the membrane. The free volume is adopted in calculating the diffusion coefficient of many gases through different polymeric membranes [25,26].

Prediction of gas diffusion (standard condition) through the polysulfone membrane is made using the Doolittle relation, and the diffusion coefficient of penetrating components into the membrane is linked to the volumetric fraction of the polymer [27,28,29].

DMio=A×eBFFV, (8)

where FFV is the fractional free volume and A (cm2 s−1) and B are constants. The FFV is estimated utilizing the Bondi method [23], as follows:

FFV=v*vov*, (9)

where, v* and vo are the specific volume of polymer and the being used specific volume, respectively. The amounts of free volume constants are listed in Table 1.

Table 1.

The free volume constants for the Doolittle Relation [27,28].

Gas A (cm2 s−1) B
CO2 2.08×105 1.09
CH4 5.24×106 1.19

The Arrhenius expression is used to consider the influence of temperature on the coefficient of gas diffusion in the polymer membrane [28].

DMi=DMioeEdRT, (10)

where Ed is the apparent activation energy for diffusion (kcal/mol). The amounts of DMio and Ed for the membrane are listed in Table 2.

Table 2.

The pre-exponential factor and apparent activation energy of gas components [28].

Gas A (cm2 s−1) Ed (Kcal/Mol)
CO2 0.02 8.3
CH4 0.074 10

2.3. Mass Transfer Coefficients

The mass transfer coefficient of the gas phase on the feed side, depending on the fluid hydrodynamic of the tube side, is estimated using the following correlation:

Shg=0.662Scg13Reg12, (11)

Shg, Scg, and Reg are the Sherwood, Schmidt, and Reynolds numbers, respectively.

kg=ShgDijd, (12)

where Dij, and d is the diffusivity of gas (i) in the gas mixture and the diameter of membrane fiber, respectively [29].

On the permeate side, the coefficient of mass transfer relies on the fluid hydrodynamic of the shell-side, which is affected by the packing density and similarity, which is affected by the packing density and similarity of the distance between fibers. From the following relationship, the mass transfer coefficient can be calculated.

Shg=5.851ϑdhLReg0.6Scg0.33, (13)

where ϑ is the packing density, L is the membrane length, and dh is the hydraulic diameter [30].

According to the model of Happel’s free surface, only a part of the gas embracing the fiber is counted, which may be considered a circular cross-section. Taking into account the active area and hexagonal form shell unit surrounding every fiber, the hydraulic diameter of the shell unit of each fiber is estimated as [31]:

A=AOAI, (14)
P=POPI, (15)
dh=4AP. (16)

Figure 2 shows the circumference and cross-sectional area of the gas slice around the outer diameter of the fibers.

Figure 2.

Figure 2

A schematic diagram for the hollow fiber membrane & cross-sectional area of permeate side [32].

Calculating the area of the hexagon was performed by dividing the total cross-sectional area of the membrane by the number of 3800 fibers, after that, finding the length of the side S, then finding the perimeter of the hexagon, and calculating the hydraulic diameter of the gas slice on the side of the permeate.

The Denes membrane mass transfer coefficient km can be calculated using the following equation:

km=DMiδ, (17)

where δ represents the thickness of the membrane layer.

3. CFD Simulation Model

A CFD simulation model of CO2 captured from the gas mixture using asymmetric HFM is developed by deriving and solving the governing equation for the three domains of the membrane. Several flow sub-models have been developed to account for flow through different module geometries. Figure 3 shows the shell, membrane, and tube domains, as well as the flow pattern and fiber side feed.

Figure 3.

Figure 3

(a) Schematic of the fiber [33] and (b) The flow geometry and the steps of the solution diffusion theory [34].

The solution-diffusion model has been used to display the mass transfer. The as follows hypotheses are considered in the formulated model:

  • -

    Steady-state and isothermal conditions.

  • -

    Fick’s law was used to describe the diffusion mechanism.

  • -

    Ideal gas behavior.

  • -

    The Newtonian-type fluid.

  • -

    Neglecting the support layer (ignoring the resistance).

  • -

    Two-dimensional flow patterns.

  • -

    The driving force in the model is the pressure difference.

  • -

    All fibers have uniform outer and inner diameters.

Based on these assumptions, the main equations governing gas separation in the membrane are derived from the material and momentum balance of the various hollow fiber composite membrane sections.

3.1. Material Balance

The continuity equations in various parts of the hollow fiber composite membrane are as follows:

3.1.1. Feed Side (Tube Side)

Equation (18) represents steady-state mass balance for the transport of gas molecules at the feed side of the natural gas mixture [30].

Di,t1rrrCi,tr+2Ci,tr=zVz,tCi,t+1rrrvr,tCi,t, (18)

where i represents every component of the gas mixture. The following equation describes the velocity profile in the tube.

For laminar flow inside the tube [35]:

VZ,t=vZ,t,max1rR2, (19)

The boundary conditions [33]:

Inlet gas conditions: Z = 0

CCO2,t=CCO2o,    CCH4,t=CCH4o, (20)

Outlet gas conditions: Z=L

nN=0,    Ni=Di,tCi,t+Ci,tui,t, (21)

At r = 0

Ci,tr=0, (22)

At r = r1

Ci,t=Ci,m/K, (23)
Ni=Di,tCi,t+Ci,tur,t (24)

3.1.2. Membrane Part

The steady-state mass balance for the transport of gas molecules from the gas mixture across the membrane skin layer is considered to be due to diffusion. Hence, the derived equation is [32]:

Di,m2Ci,mr2+1rCi,mr+2Ci,mz2=0, (25)

The boundary conditions:

Membrane interface (considering solubility):

r=r1,    Ci,m=CDi+CHi=Sipi+CH´ibipi/1+bipi, (26)

At r = r1

Ci,m=Ci,t×K, (27)
Ni=Di,mCi,m, (28)

At r = r2

Ci,m=Ci,s×K, (29)
Ni=Di,mCi,m, (30)

At z = 0, z = L

n·N=0, (31)
Ni=Di,mCi,m. (32)

3.1.3. Permeate Side

The steady-state material balance for the transport of gas molecules from the gas mixture on the permeate side is considered to be due to diffusion and convection [32].

Di,p1rrrCi,pr+2Ci,pr=zVz,pCi,p+1rrrvr,pCi,p, (33)

Equation (34) was used to minimize the deviation into the velocity profile on the shell side [34]:

Vz,p=vz,pmaxrr42r3r42+2lnr3r3+r3r444r3r42+4lnr3r4, (34)

At r = r3

Ci,p=Ci,s, (35)
Ni=Di,pCi,p+Ci,pui,p, (36)

At z = 0, z = L

n·N=0, (37)
Ni=Di,pCi,p+Ci,pui,p. (38)

Equations (39)–(50) represent the Navier–Stokes equation with boundary conditions which were used to estimate the velocity profiles at tube and shell sides:

3.1.4. Feed Side (Tube Side)

r-direction:

ρgvr,tvr,tr+vz,tvz,tz=ptr+μgr1rrrvr,t+2vr,tz2, (39)

z-direction:

ρgvr,tvz,tr+vz,tvz,tz=ptz+μgr1rrrv,t+2vz,tz2+g, (40)

At r = 0

vz,tr=0,   vr,t=0, (41)

Velocity near membrane walls:

r=r1,  vz,t=0,  vr,t=0, (42)

Inlet velocity of feed gas:

z=0,  vz,t=vo,t,  vr,t=0, (43)

Outlet velocity of feed gas:

z=L,    vz,tz=0,    vr,t=0. (44)

3.1.5. Shell Side

The Navier–Stockes equation is given:

r-direction:

ρgvr,svr,sr+vz,svz,sz=psr+μgr1rrrvr,s+2vr,sz2, (45)

Z-direction:

ρgvr,tvz,sr+vz,svz,sz=psz+μgr1rrrvz,s+2vz,sz2+g, (46)

Boundary conditions utilized:

Membrane gas interface:

r=r3,  vz,s=0,  vr,s=0, (47)

Axial symmetry at module hypothetical radius:

r=r3,  vz,sz=0,  vr,s=0, (48)

The outlet of the gas flow in the shell side:

z=L,  vz,sz=0,  vr,s=0, (49)

Inlet gas velocity:

z=0,  vz,s=0,  vr,s=0. (50)

Operation conditions, membrane characteristics, diffusion coefficients, partition factors, and the other transport properties that were used for solving the mass transfer equations are given in Table 3.

Table 3.

The input variables for the proposed model in COMSOL 5.6.

Parameter Value Unit Parameter Value Unit
Temperature of a gas mixture 303 K %CO2 in Feed 6 mol%
Pressure of a gas mixture 5 bar %CH4 in Feed 94 mol%
Feed Flow Rate 3.33 × 10−5 m3/s The density of feed gas 3.59 kg/m3
Inlet Conc. of CO2 1.20 × 101 mol/m3 The viscosity of the feed gas 1.15 × 10−5 g/cm.s
Inlet Conc. of CH4 1.83 × 102 mol/m3 The inner radius of the fibre 90 μm
Inlet gas velocity in fibre 0.345 m/s The outer radius of the fibre 150 μm
Number of fibres 3800 - The thickness of the dense layer 20 μm
Scale 300 - Length of fibre 28 cm
Diffusion Coef. of CO2 in Tube Side 3.39 × 10−5 m2/s Partition Factor of CO2 0.801 -
Diffusion Coef. of CH4 in Tube Side 3.36 × 10−6 m2/s Partition Factor of CH4 0.441 -
Diffusion of CO2 in Membrane 2.29 × 10−8 m2/s Density of permeate gas 0.87 kg/m3
Diffusion of CH4 in Membrane 3.1 × 10−9 m2/s Viscosity of the permeate gas 1.24 × 10−5 g/cm.s
Diffusion Coefficients of CO2 in Permeate Side 1.72 × 10−5 m2/s Diffusion Coefficients of CH4 in Permeate Side 1.72 × 10−5 m2/s

3.2. Numerical Procedure

The model equations regarding the shell side, membrane, and tube side with the proper boundary conditions were solved utilizing COMSOL Multiphysics (5.6) software, using the technique of finite element (FEM). The time for treating the collection of equations was around 43 s. Figure 4 illustrates a part of the mesh utilized to decide the gas transport behavior in a hollow fiber membrane (HFM). It must be indicated that the COMSOL mesh generator makes triangular meshes that are isotropic in volume. Great numbers of components are then made with scaling. A scaling parameter of 300 was used in the z-direction due to a large variance between r and z. COMSOL spontaneously tabulates back the geometry after meshing. This makes an additional fine mesh of about 76,742 degrees of freedom solved and 2384 internal DOFs.

Figure 4.

Figure 4

Model domain and meshes used for simulation.

4. Experimental Work

4.1. Materials and Experimental Design

In this study, a commercial membrane-type MCB-1512A purchased from the Korean company Airrane was used. The membrane, consisting of polysulfone, possesses high selectivity in carbon dioxide separation but low permeance. The low permeability problem is overcome by making the membrane fibers asymmetrically composed of several layers. All information related to this model of membranes has been provided by the company in Table 4.

Table 4.

Specifications of the CO2 separation membrane module [36].

Specifications of Membrane Module
Product Model Material
Hollow fibre MCB-1512A Polysulfone
Dimensions and Weight
Length Dimension Weight
360 mm 55 mm 0.9 kg
Fibre Specifications
No. length OD ID
3800 280 mm 300 μm 160180 μm
Operating Conditions
Pressure Temp. (Min/Max) Relative Humidity Residual oil
Max 10 bar 5/50 Less than 60% ≤0.01 mg/m3

In addition to the information provided by the manufacturer, a Scanning Electron Microscopy (SEM) test was performed for the fibers, wherein the number of layers that make up each fiber, as well as the dimensions of each layer was determined. The SEM images of the hollow fibers showed an external diameter of 351.51 µm and an internal diameter of 219.87 µm (Figure 5).

Figure 5.

Figure 5

SEM snapshots of hollow fiber membrane.

Through the cross-section of the fiber shown in Figure 5, the thickness of the dense layer is 20 μm and the thickness of the support layer is 40 μm.

In this work, three independent variables were selected: pressure feed, temperature feed, and the percentage of carbon dioxide in the feed. Meanwhile, the concentration of carbon dioxide in the permeate and flux are the two dependent variables. The selection of the parameters that were studied was based on the design limits of the membrane used for both pressure and temperature. As for the percentage of carbon dioxide, it was based on the analysis of natural gas in the fields of the Maysan Oil Company. The limits and steps of all these variables are based on which of the experiments were designed in the MINITAB program and according to the type of Taguchi, which are shown in the following Table 5.

Table 5.

Limits and steps of the study parameters.

Step No. Feed Pressure (Bar) Feed Temp. (°C) CO2 in Feed Mol%
1 2.5 20 2
2 5 30 6
3 7.5 40 10

In all the experiments, the feed flow rate was adjusted at 3.5084 L/min. At steady-state conditions, the permeate stream was sent to (Gas chromatography) GC, and its mole fraction (volume fraction) was measured, while the permeate flow was measured using a bubble meter. Table 6 represents the number of runs with the results obtained after conducting the experiments, and it includes the percentage of carbon dioxide in the reject.

Table 6.

The runs with the results obtained after conducting the experiments.

Run Feed Pressure
(Bar)
Feed Temp.
(°C)
CO2 Mol%
Feed
CH4 Mol%
Feed
Permeate Flow Rate
(L/Min)
CO2 Mol%
Permeate
CH4 Mol%
Permeate
1 2.5 20 2 98 0.334 23.013 76.982
2 2.5 20 2 98 0.3336 22.807 77.191
3 2.5 20 2 98 0.3329 22.43 77.568
4 2.5 30 6 94 0.2984 25.308 74.691
5 2.5 30 6 94 0.301 24.704 75.294
6 2.5 30 6 94 0.299 25.5304 74.467
7 2.5 40 10 90 0.2798 28.675 71.324
8 2.5 40 10 90 0.2761 27.324 72.673
9 2.5 40 10 90 0.2775 28.3201 71.678
10 5 20 2 98 0.612245 31.054 68.943
11 5 20 2 98 0.623 30.876 69.123
12 5 20 2 98 0.6204 31.342 68.655
13 5 30 6 94 0.5307 33.05 66.947
14 5 30 6 94 0.549 33.245 66.753
15 5 30 6 94 0.533 32.991 67.005
16 5 40 10 90 0.4558 35.343 64.654
17 5 40 10 90 0.459 34.673 65.326
18 5 40 10 90 0.4502 35.457 64.541
19 7.5 20 6 94 0.846 37.325 62.672
20 7.5 20 6 94 0.842 37.01 62.987
21 7.5 20 6 94 0.839 37.123 62.872
22 7.5 30 10 90 0.811 39.861 60.136
23 7.5 30 10 90 0.806 39.918 60.079
24 7.5 30 10 90 0.813 40.023 59.973
25 7.5 40 2 98 0.661 34.87 65.128
26 7.5 40 2 98 0.669 35.674 64.323
27 7.5 40 2 98 0.6605 34.9108 65.088

4.2. Lab Scale System and Gas Analyzers

Experiments were conducted to separate carbon dioxide from the gas mixture using a laboratory system, shown in Figure 6.

Figure 6.

Figure 6

Flow diagram of the lab-scale system.

In this study and during laboratory experiments, the gas is analyzed by taking samples from two points in the laboratory system; the first is from the gas mixture feeding the membrane, and the second is from the gas mixture separated by the membrane. In the first point, the gas sample is analyzed by the Dräger Short-term Tubes. The second sample is analyzed by connecting the permeate side with the GC device using an online connection.

5. Results and Discussion

In this work, the flux was calculated once from the mathematical model and again from the results of the simulation model that was developed by COMSOL 5.6 and compared between them. Calculating the flux utilizing the resistance in a series model, represented by Equation (4), requires finding the diffusivity through the different domains of the membrane, as well as the mass transfer coefficient, permeability, and solubility. The effect of operating conditions in this study on the mentioned parameters was investigated as follows.

5.1. Effect of Pressure and Temperature on Diffusion Coefficients

The diffusivity of each component was calculated using Hirschfelder’s equation for the binary mixture [37]. In this work, the impacts of temperature and pressure on the coefficients of diffusion were investigated in both the feed and permeate regions. Figure 7 and Figure 8 show the influence of pressure and temperature on the diffusivity in the feed side of the two gases separately in the mixture.

Figure 7.

Figure 7

Influence of the gas temperature on coefficients of diffusion in feed side at Pf = 5 bar, CO2 = 6 mol%, and CH4 = 94 mol%.

Figure 8.

Figure 8

Influence of the pressure on coefficients of gases in feed side at Tf = 303 K, CO2 = 6 mol%, and CH4 = 94 mol%.

Figure 7 plots the influence of temperature on the coefficient of diffusion of gases in the feed side at the temperature range of 293–318 K. The coefficient of diffusion of gases rises with enhancing temperature. This behavior can be justified by Hirschfelder’s equation [37]. Regarding the effect of pressure, generally, the coefficient of diffusion is inversely proportional to the pressure, and this is proved by Figure 8 [38,39].

On the permeate side, the pressure value is constant at one atmosphere for all feed pressure values, while the temperature is similar to the temperature of the gas mixture entering the separation unit. The change in diffusion here corresponds to the change in the feeding side under the same temperature with constant pressure at atmospheric pressure.

On the other hand, the increase in the amount of carbon dioxide in the gas mixture has a slight adverse effect on the diffusion of the gas itself and a slight direct change on the diffusion of methane. Figure 9 shows that the gas diffusivity changes with an increase in mole percent of CO2 in the feed at constant pressure at 5 bar and temperature at 303 K.

Figure 9.

Figure 9

Effect of the percentage of CO2 on coefficients of diffusion of gases in feed side at Pf = 5 bar and Tf = 303 K.

5.2. Effect of Temperature and Pressure on Mass Transfer Coefficients

The mass transfer coefficient at both the feed side and permeate side depends on the hydrodynamic of the fluid, calculated from the Reynolds, diffusivity of gas, and Sherwood and Schmidt’s numbers using Equations (11)–(13). On the feed side, the inner diameter of the fiber is used, while on the permeate side, the hydraulic diameter (Equation (16)) is used in both equations. Figure 10 shows the impact of temperature on the mass transfer coefficient of feed gases at constant pressure.

Figure 10.

Figure 10

Influence of the temperature on the coefficient of mass transfer of gases in feed side at Pf = 5 bar, CO2 = 6 mol%, and CH4 = 94 mol%.

Figure 10 plots the influence of temperature on the coefficient of mass transfer of gases in the feed side at a temperature range of 293–318 K. Increasing the temperature leads to a change in the values of the parameters on which the value of the mass transfer coefficient depends. When the temperature changes from 293 K to 318 K, the value of the parameters changes in different proportions, and the Reynolds number and Sherwood number decrease by 14.1% and 7.35%, respectively.

On the other hand, the diffusivity and viscosity values increase by 16.67% and 7.1%, respectively, while the value of the Schmidt number remains constant. The behavior of the mass transfer coefficient with a change in pressure with constant temperature and gas composition is illustrated in Figure 11.

Figure 11.

Figure 11

Influence of the pressure on coefficient of mass transfer of gases in feed side at Tf = 303 K, CO2 = 6 mol%, and CH4 = 94 mol%.

Figure 11 depicts that the coefficient of mass transfer of the two gases is related to an exponential relationship with the pressure, and its value decreases with the increase in the pressure of the feed.

Figure 12 shows the mass transfer coefficient of the gases change with the increase in mole percent of CO2 in the feed at constant pressure at 5 bar and temperature at 303 K. From this figure, the behavior of the coefficient of mass transfer is very similar to the behavior of diffusivity when changing the proportion of CO2 in the feed.

Figure 12.

Figure 12

Effect of the percentage of CO2 on mass transfer coefficient of gases in fees side at Pf = 5 bar and Tf = 303 K.

On the permeate side, the value of the coefficient of mass transfer differs compared to the feed side for two main reasons, the first is the difference in gas concentrations, as well as the stability of pressure at one atmosphere, and the second reason is the adoption of the hydraulic diameter of the outer circumference of the membrane fibers when calculating the coefficient of mass transfer.

In this domain, the value of the mass transfer coefficient is equal for both gases with the change in temperature and carbon dioxide concentration. The relationship between the mass transfer coefficient, temperature, and gas concentration is a direct relationship on this side of the membrane.

5.3. The Diffusion Coefficient of Gases in the Dense Membrane

The solution to mass transfer equations is based on calculating the diffusivity value of the gas mixture species in the membrane. Simply put, the voids between the polymeric chains in the membrane provide a passage path for the permeating gas molecules. The free volume theory has usually been utilized to evaluate the coefficient of diffusion of gaseous species out of different polymeric membranes [27].

In this present study, the diffusivity of carbon dioxide and methane was calculated in two stages. In the first, the Doltile relationship was used, in which the effect of temperature does not appear [23,39]. As for the second stage, the influence of temperature on the diffusivity of gases was introduced using the Arrhenius relationship. The diffusivity values are 2.28787 × 10−8 cm2/s and 3.08508 × 10−9 cm2/s for each carbon dioxide and methane, respectively, calculated from Equation (8). On the other hand, the temperature change within the range used in this study on the diffusion of gases was investigated using Equation (10). Figure 13 represents the effect of temperature on the diffusivity of the gases that consist of the feed mixture.

Figure 13.

Figure 13

Influence of the temperature on the diffusivity of CO2 and CH4.

By analyzing the results in the above diagram, the ratio of carbon dioxide diffusion to the methane gas diffusivity decreased from 5.01 to 3.98 when the temperature changed from 293 K to 318 K, while the change in diffusivities for each degree of temperature was 1.06408 × 10−9 for CO2 and 2.93641 × 10−10 for CH4.

5.4. Model Validation

One of the most important validation tools for the proposed CFD model is to compare its results with experimental results [32]. The simulation results of the CO2 flux were compared with experimental results. There is a fine accordance between the CFD model and experimental results, with an utmost um relative mistake of 7.73%. Table 7 shows the fluxes obtained from both the CFD model and the mathematical model based on experimental data.

Table 7.

Comparison of the mathematical model results with the CFD model.

PF
Bar
TF
K
XF
Mol/Mol
Flux. Exp
Mol/m2·S
Flux. Com
Mol/m2·S
Relative
Error
Recovery
%CO2
2.5 293 2 7.31 × 10−9 6.93 × 10−9 5.26 9
2.5 303 6 2.07 × 10−8 2.00 × 10−8 3.31 18.65
2.5 313 10 1.04 × 10−6 9.56 × 10−7 7.73 19.1
5 293 2 1.42 × 10−8 1.38 × 10−8 2.63 19.2
5 303 6 2.24 × 10−6 2.01 × 10−6 5.94 21.4
5 313 10 8.96 × 10−6 8.57 × 10−6 4.36 23.4
7.5 293 6 9.49 × 10−6 9.22 × 10−6 2.83 28.3
7.5 303 10 2.39 × 10−5 2.31 × 10−5 3.33 30.3
7.5 313 2 2.18 × 10−8 2.17 × 10−8 0.391 20.6

5.4.1. Velocity Field

The velocity field, profile, contour, and 3D profile in the tube side of the HFM are seen in Figure 14, Figure 15, Figure 16 and Figure 17, in which the gas mix streams. The velocity profile in the tube side of the HFM was simulated by solving Navier–Stokes’s equations.

Figure 14.

Figure 14

Field of velocity in the feed-side of the HFMC. Flow of gas = 3.333 × 10−5 (m3/s), Tf = 303 K, and Pf = 5 bar.

Figure 15.

Figure 15

Profile of velocity in the feed-side across the length of membrane; Flow of gas = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar.

Figure 16.

Figure 16

The contour of velocity in the feed-side of the HFM. Flow of gas = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar.

Figure 17.

Figure 17

3D Profile of velocity in the feed-side across the membrane length. Flow of gas = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar.

The profile of velocity is usually parabolic, with a maxima velocity that rises along the length of the membrane from 0.34683 m/s in the inlet to 0.45083 m/s in the outlet. Moreover, it reveals that at the entrance zones on the feed side, the velocity is undeveloped. After distancing from the entrance, the profile of velocity is totally developed. As seen, the model counts the inlet effects on the fluid flow hydrodynamics on the feed side. The velocity distribution on the shell side is obtained by solving the Navier–Stoke equations and material balance equations in conjunction with Happel’s free surface model. This mode is mainly used for HFM and proposes a parabolic velocity profile for the flow outside of the fiber (Equation (34)). The velocity field, profile, contour, and 3D profile in the shell side of the HFM are seen in Figure 18, Figure 19, Figure 20 and Figure 21.

Figure 18.

Figure 18

Field of velocity in the shell side of the HFMC. Flow of gas = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar.

Figure 19.

Figure 19

Profile of velocity in the shell side across the membrane length. Flow of gas = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar. Each color represents a different section from length along the fiber.

Figure 20.

Figure 20

Velocity Contour in the sell side of the HFM. Flow of gas = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar.

Figure 21.

Figure 21

3D profile of velocity in the shell side across the membrane length. Gas flow rate = 3.333 × 10−5 (m3/s), Tf =303 K, and Pf = 5 bar.

From the velocity profile, the average velocity rises with the membrane length due to the continuous CO2 gas permeation. The average velocity for any step of the Z value from the total length of the fiber can be calculated from the following formula:

Vzshell=r2r3V(r)zshelldAr2r3dA. (51)

Calculating the average velocity at both ends of the fiber, its value was 1.362 × 10−4 (m/s) at the closed end of the shell, while the average velocity at the exit was 0.084923 (m/s). The increase in this speed is due to the flux of carbon dioxide gas through the membrane from the feed side to the shell side during the separation process.

5.4.2. The Concentration Distribution of Gas in the Membrane

The equations of continuity, moment, and mass transfer for the three domains in the membrane model were solved for both carbon dioxide and methane. Figure 22 describes the CO2 concentration gradient in the tube, the membrane, and the shell of the hollow fiber membrane.

Figure 22.

Figure 22

The concentration gradient of CO2 in the model domains at feed flow = 3.333 × 10−5 (m3/s), Tf = 30 °C, Pf = 5 bar, and XCO2 = 0.06.

When the gas moves along the tube, CO2 transmits to the membrane due to the concentration gradient. Considering Figure 16, at z = 0 where the gas inflows the HFM, the CO2 concentration has a peak value amounting to 11.909 mol/m3, while on the permeate side of the membrane, the average concentration of CO2 is equal to 11.723 mol/m3 at z = L. The mechanisms of mass transfer in the tube and the shell are diffusion and convection. Since the flow is in the z-direction, the mass is transmitted by convection. In the radial direction, diffusion performs the main role in the phenomena of mass transfer. Carbon dioxide gas flows by the diffusion mechanism, where it is absorbed on the surface of the membrane and transferred to the other side [32]. Figure 23 illustrates a 2D concentration difference with the overall flow vectors of CO2. Moreover, a 3D concentration gradient of CO2 is seen in Figure 24, only for the best conception of the transfer of mass.

Figure 23.

Figure 23

Vectors of overall flux in the sections of the model at feed flow = 3.333 × 10−5 (m3/s), Tf = 30 °C, Pf = 5 bar, and XCO2 = 0.06.

Figure 24.

Figure 24

The 3D concentration gradient of CO2 in all domains at feed flow = 3.333 × 10−5 (m3/s), Tf = 30 °C, Pf = 5 bar, and XCO2 =0.06.

It is also possible through the COMSOL model to obtain accurate results about the mass transfer, especially in the area of the boundary layer and the concentrations of carbon dioxide on the two faces of the membrane. Figure 25 shows a one-dimensional concentration gradient of carbon dioxide through the region of the tube, membrane, and shell at 15% of the fiber length. At 0L (fiber entrance) of the tube length, the mass transfer of the CO2 was only on the first surface of the membrane and at a concentration of 8.8605 mol/m3. After 5% of the tube length, there was a noticeable transfer of carbon dioxide gas to the permeate side of the membrane, where the gas concentrations on the first and second surfaces of the membrane were 9.35 and 7.1083 mol/m3, respectively. Table 8 presents the concentrations of carbon dioxide on the sorption side and desorption side in the membrane.

Figure 25.

Figure 25

The one-dimension concentration gradient of CO2 in all domains.

Table 8.

The concentrations of carbon dioxide in the sorption and desorption side in the membrane.

Length of Fiber
m
Conc. of CO2 at r1
Mol/m3
Conc. of CO2 at r2
Mol/m3
0 8.8605 0
0.014 9.3512 7.1083
0.028 9.4065 8.4672
0.042 9.4901 9.089

By making simple calculations for the results in Table 8, it can be noted that the carbon dioxide concentration has risen to 95% of the highest concentration (9.539 mol/m3) of the gas on the desorption surface. This indicates that the effectiveness of mass transfer to length is very high at the beginning of the fiber.

5.5. Analysis of CO2 Flux and Recovery

The experimental results in Table 7 were analyzed by Minitab.18 to discover the effect of pressure, temperature, and concentration on the flux of carbon dioxide through the membrane. Figure 26 illustrates the effect of pressure on the flux of CO2 in the membrane at a pressure range of 2–10 bar. It is clear in Figure 26 that the flux increases with increasing pressure, due to increasing the equilibrium concentration of carbon dioxide on the surface of the membrane. The increase in the concentration difference on the two surfaces of the membrane represents an increase in the driving force in the law of flux.

Figure 26.

Figure 26

The effect of pressure on the flux of CO2 in the membrane.

Figure 27 shows the effect of carbon dioxide concentration in the feed on the flux through the membrane. The relationship of flux to concentration is a direct type, as shown in the Figure. The reason for this is that the mass transfer across the two faces of the membrane is due to the concentration difference, and the higher the numerical value of this difference the higher the transfer rate.

Figure 27.

Figure 27

The effect of concentration of CO2 on the flux in the membrane.

The effect of the third factor represented by temperature is almost non-existent on flux, due to the effect of temperature inversely on the gas solubility of the membrane polymer and directly on the diffusion of the gas across the membrane. Since permeability is the product of these two factors, the temperature does not affect flux.

After analyzing the results, the role of the most important step comes, which is to find the optimal conditions that guarantee the highest recovery in the membrane. The optimum conditions are found to be 7.5 bar for pressure, 293 K for temperature, and 10% for CO2 concentration, while at a pressure of 2.5 bar, 293.57 K, and 2% CO2, flux and recovery would be at non-optimal conditions.

6. Conclusions

In this work, the capture of carbon dioxide using a dense hollow fiber membrane was studied experimentally and theoretically. Twenty-seven experiments have been conducted using a mixture of methane and carbon dioxide to simulate natural gas. A comprehensive mathematical model was developed to describe the flux of CO2 through the membrane. The flux was calculated, taking into consideration the effect of pressure, temperature, and concentration on the properties of the gas mixture, such as density, viscosity, diffusivity, solubility, and mass transfer coefficient. Through the results, the two most controlling factors in the mass transfer were pressure and concentration. Then, a 2D axisymmetric model of a multilayer hollow fiber composite membrane for CO2 segregation was suggested. The model considers the axial and radial diffusion in the HFM. CFD mechanisms were adopted to work out the model equations including continuity and momentum equations. The CFD model predicted the two-dimensional velocity, pressure, and concentration profiles in three domains of the fiber. Modeling forecastings were supported by the experimental results, and a reasonable harmony between them was observed. The relative error between the results of the mathematical model and the CFD model in calculating the flux ranged from 0.391 to 7.73%. The results also showed the direct effect of each of the pressures and the concentration of carbon dioxide in the feed on the flux, while the feed temperature had no obvious effect. The developed model can be used to predict the performance of membranes made of different polymers as well as other operational conditions. The limitation of this upgraded model is its use of low carbon dioxide concentrations as well as pressures that do not exceed 15 bar for the feed.

Acknowledgments

The authors extend their appreciation to the Deanship of Scientific Research at King Khalid University for funding this work through a Large Group Research Project under grant number RGP2/133/44. We would also like to thank the Missan Oil Company for its infinite cooperation and continuous help.

Author Contributions

Theory, D.J.J. and T.J.M.; experimental testing, D.J.J. and T.J.M.; modelling, D.J.J. and M.F.A.; drafting, D.J.J. and M.F.A.; validation, D.J.J. and T.J.M.; editing, R.H.H.; supervision, A.A. and H.N.H. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Funding Statement

This research was funded by the Deanship of Scientific Research at King Khalid University under grant number RGP2/133/44.

Footnotes

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

References

  • 1.Mustafa J., Farhan M., Hussain M. CO2 Separation from Flue Gases Using Different Types of Membranes. J. Membr. Sci. Technol. 2016;6:153–159. doi: 10.4172/2155-9589.1000153. [DOI] [Google Scholar]
  • 2.Rath G.K., Pandey G., Singh S., Molokitina N., Kumar A., Joshi S., Chauhan G. Carbon Dioxide Separation Technologies: Applicable to Net Zero. Energies. 2023;16:4100. doi: 10.3390/en16104100. [DOI] [Google Scholar]
  • 3.Altalhi M.L.T., Ahamed M.I. Advanced Functional Membranes: Materials and Applications. Materails Research Forum LLC; Millersville, PA, USA: 2022. [Google Scholar]
  • 4.Mohanty K., Purkait M.K. Membrane Technologies and Applications. 1st ed. CRC Press; Boca Raton, FL, USA: 2011. [Google Scholar]
  • 5.Bernardo P., Drioli E., Golemme G. Membrane Gas Separation: A Review/State of the Art. Ind. Eng. Chem. Res. 2009;48:4638–4663. doi: 10.1021/ie8019032. [DOI] [Google Scholar]
  • 6.Drioli E., Giorno L., Macedonio F. Membrane Engineering. 1st ed. Walter de Gruyter GmbH & Co KG; Berlin, Germany: 2018. [Google Scholar]
  • 7.Hamid M.A.A., Chung Y.T., Rohani R., Junaidi M.U.M. Miscible-blend polysulfone/polyimide membrane for hydrogen purification from palm oil mill effluent fermentation. Sep. Purif. Technol. 2019;209:598–607. doi: 10.1016/j.seppur.2018.07.067. [DOI] [Google Scholar]
  • 8.Jasim D., Mohammed T., Abid M. A Review of the Natural Gas Purification from Acid Gases by Membrane. Eng. Technol. J. 2022;40:441–450. doi: 10.30684/etj.v40i3.1983. [DOI] [Google Scholar]
  • 9.Scholz M., Wessling M., Balster J. Membrane Engineering for the Treatment of Gases. Volume 1. RSC publishing; London, UK: 2011. Design of Membrane Modules for Gas Separations; pp. 125–149. [Google Scholar]
  • 10.Lasseuguette E., Comesaña-Gándara B. Polymer Membranes for Gas Separation. Membranes. 2022;12:207. doi: 10.3390/membranes12020207. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Alshehri A.K. Ph.D. Thesis. King Abdullah University of Science and Technology; Thuwal, Saudi Arabia: 2015. Membrane Modeling, Simulation and Optimization for Propylene/Propane Separation. [Google Scholar]
  • 12.Ji G., Zhao M. Recent Advances in Carbon Capture and Storage. IntechOpen; London, UK: 2017. Membrane Separation Technology in Carbon Capture. [Google Scholar]
  • 13.Yampolskii Y., FInkelshtein E. Membrane Materials for Gas and Separation: Synthesis and Application fo Silicon-Containing Polymers. John Wiley & Sons, Ltd.; Pondicherry, India: 2017. [Google Scholar]
  • 14.Imtiaz A., Othman M.H.D., Jilani A., Khan I.U., Kamaludin R., Iqbal J., Al-Sehemi A.G. Challenges, Opportunities and Future Directions of Membrane Technology for Natural Gas Purification: A Critical Review. Membranes. 2022;12:646. doi: 10.3390/membranes12070646. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Dehkordi J.A., Hosseini S.S., Kundu P.K., Tan N.R. Mathematical Modeling of Natural Gas Separation Using Hollow Fiber Membrane Modules by Application of Finite Element Method through Statistical Analysis. Chem. Prod. Process Model. 2016;11:11–15. doi: 10.1515/cppm-2015-0052. [DOI] [Google Scholar]
  • 16.Marriott J.I. Ph.D. Thesis. University of London; London, UK: Feb, 2001. Detailed Modelling and Optimal Design of Membrane Separation Systems; pp. 1–224. [Google Scholar]
  • 17.Wang K.Y., Weber M., Chung T.S. Polybenzimidazoles (PBIs) and state-of-the-art PBI hollow fiber membranes for water, organic solvent and gas separations: A review. J. Mater. Chem. A. 2022;10:8687–8718. doi: 10.1039/D2TA00422D. [DOI] [Google Scholar]
  • 18.Seader J.D., Henley E.J., Roper D.K. Separation Process Principles Chemical and Biochemical Operations. 3rd ed. John Wiley & Sons, Inc.; Hoboken, NJ, USA: 2011. [Google Scholar]
  • 19.Cardoso A.R.T., Ambrosi A., Di Luccio M., Hotza D. Membranes for separation of CO2/CH4 at harsh conditions. J. Nat. Gas Sci. Eng. 2022;98:104388. doi: 10.1016/j.jngse.2021.104388. [DOI] [Google Scholar]
  • 20.Ismaila A.F., Kusworoa T.D., Mustafaa A., Hasbullaha H. Understanding the solution-diffusion mechanism in gas separation membrane for engineering students; Proceedings of the Regional Conference on Engineering Education RCEE 2005; Johor, Malaysia. 12–13 December 2005. [Google Scholar]
  • 21.Engineering ToolBox. Carbon Dioxide—Dynamic and Kinematic Viscosity. [(accessed on 14 January 2021)]. Available online: https://www.engineeringtoolbox.com/carbon-dioxide-dynamic-kinematic-viscosity-temperature-pressure-d_2074.html.
  • 22.Smith J.M., Van Ness H.C., Abbott M.M., Swihart M.T. Introduction to Chemical Engineering Thermodynamics. McGraw-Hill; Singapore: 2018. [Google Scholar]
  • 23.Bondi A. Van der Waals Volumes and Radii. J. Phys. Chem. 1694;68:441–451. doi: 10.1021/j100785a001. [DOI] [Google Scholar]
  • 24.Thran A., Kroll C., Faupel F. Correlation between fractional free volume and diffusivity of gas molecules in glassy polymers. J. Polym. Sci. Part B Polym. Phys. 1999;37:3344–3358. doi: 10.1002/(SICI)1099-0488(19991201)37:23<3344::AID-POLB10>3.0.CO;2-A. [DOI] [Google Scholar]
  • 25.Shoghl S.N., Raisi A., Aroujalian A. A predictive mass transport model for gas separation using glassy polymer membranes. RSC Adv. 2015;5:38223–38234. doi: 10.1039/C5RA00988J. [DOI] [Google Scholar]
  • 26.Shoghl S.N., Raisi A., Aroujalian A. Modeling of gas solubility and permeability in glassy and rubbery membranes using lattice fluid theory. Polymer. 2017;115:184–196. doi: 10.1016/j.polymer.2017.03.032. [DOI] [Google Scholar]
  • 27.Minelli M., Sarti G. Thermodynamic Modeling of Gas Transport in Glassy Polymeric Membranes. Membranes. 2017;7:46. doi: 10.3390/membranes7030046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Costello L.M., Koros W.J. Temperature dependence of gas sorption and transport properties in polymers: Measurement and applications. Ind. Eng. Chem. Res. 1992;31:2708–2714. doi: 10.1021/ie00012a012. [DOI] [Google Scholar]
  • 29.Coulson J.M., Richardson J.F., Backhurst J.R., Harker J.H. Fluid flow, heat transfer and mass transfer. Filtr. Sep. 1996;33:102. doi: 10.1016/S0015-1882(96)90353-5. [DOI] [Google Scholar]
  • 30.Ghasem N., Al-Marzouqi M. Modeling and experimental study of carbon dioxide absorption in a flat sheet membrane contactor. J. Membr. Sci. Res. 2017;3:57–63. doi: 10.22079/jmsr.2016.20226. [DOI] [Google Scholar]
  • 31.Zhang Z., Chen F., Rezakazemi M., Zhang W., Lu C., Chang H., Quan X. Modeling of a CO2-piperazine-membrane absorption system. Chem. Eng. Res. Des. 2018;131:375–384. doi: 10.1016/j.cherd.2017.11.024. [DOI] [Google Scholar]
  • 32.Rezakazemi M., Niazi Z., Mirfendereski M., Shirazian S., Mohammadi T., Pak A. CFD simulation of natural gas sweetening in a gas-liquid hollow-fiber membrane contactor. Chem. Eng. J. 2011;168:1217–1226. doi: 10.1016/j.cej.2011.02.019. [DOI] [Google Scholar]
  • 33.Amooghin A.E., Mirrezaei S., Sanaeepur H., Sharifzadeh M.M.M. Gas permeation modeling through a multilayer hollow fiber composite membrane. J. Membr. Sci. Res. 2020;6:125–134. doi: 10.22079/JMSR.2019.112328.1281. [DOI] [Google Scholar]
  • 34.Alsaiari A.O. Gas-Gas Separation Using a Hollow Fiber Membrane. Lehigh University; Bethlehem, PA, USA: 2014. [Google Scholar]
  • 35.Byron Bird W.E.S.R., Lightfoot E.N. Transport Phenomena. 2nd ed. Volume 58 Cambridge University Press; Cambridge, UK: 2013. [Google Scholar]
  • 36.AIRRANE. [(accessed on 15 July 2022)]. Available online: https://www.biogasworld.com/companies/airrane/
  • 37.Asano K. Mass Transfer. John Wiley & Sons; Hoboken, NJ, USA: 2012. [Google Scholar]
  • 38.Chou C.-H., Martin J.J. Diffusion of Gases at Elevated Pressures—Carbon-14—Labeled CO2 in CO2—H2 and CO2—Propane. Ind. Eng. Chem. 1957;49:758–762. doi: 10.1021/ie50568a043. [DOI] [Google Scholar]
  • 39.Zielinski J.M., Duda J.L. Predicting polymer/solvent diffusion coefficients using free-volume theory. AIChE J. 1992;38:405–415. doi: 10.1002/aic.690380309. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Not applicable.


Articles from Membranes are provided here courtesy of Multidisciplinary Digital Publishing Institute (MDPI)

RESOURCES