Abstract
We proposed a new mathematical model that combines an ordinary differential equation (ODE) and microdosimetric kinetic model (MKM) to predict the tumor-cell lethal effect of Stereotactic body radiation therapy (SBRT) applied to non-small cell lung cancer (NSCLC). The tumor growth volume was calculated by the ODE in the multi-component mathematical model (MCM) for the cell lines NSCLC A549 and NCI-H460 (H460). The prescription doses 48 Gy/4 fr and 54 Gy/3 fr were used in the SBRT, and the effect of the SBRT on tumor cells was evaluated by the MKM. We also evaluated the effects of (1) linear quadratic model (LQM) and the MKM, (2) varying the ratio of active and quiescent tumors for the total tumor volume, and (3) the length of the dose-delivery time per fractionated dose (tinter) on the initial tumor volume. We used the ratio of the tumor volume at 1 day after the end of irradiation to the tumor volume before irradiation to define the radiation effectiveness value (REV). The combination of MKM and MCM significantly reduced REV at 48 Gy/4 fr compared to the combination of LQM and MCM. The ratio of active tumors and the prolonging of tinter affected the decrease in the REV for A549 and H460 cells. We evaluated the tumor volume considering a large fractionated dose and the dose-delivery time by combining the MKM with a mathematical model of tumor growth using an ODE in lung SBRT for NSCLC A549 and H460 cells.
Subject terms: Computational science, Cancer models, Radiotherapy, Non-small-cell lung cancer
Introduction
Stereotactic body radiation therapy (SBRT), which is widely used in the treatment of early-stage non-small cell lung cancer (NSCLC), is characterized by delivering high doses with a small number of divisions1–3. A rapid dose reduction from the target and optimal target dose compatibility are critical to minimizing toxicity to normal tissue when SBRT is administered4,5. In a comparison of the outcomes of SBRT and surgery, there was no significant difference in the percentage of patients who were alive at 5 years after treatment: 87% for SBRT versus 84% for surgery. There was also no significant difference in the percentage of patients who were alive without recurrence at 5 years after treatment: 77% for SBRT versus 80% for surgery. Severe complications associated with treatment were less common with SBRT (about 1%) than with surgery6. There were no instances of 90 days mortality (0%), the bleeding requiring re-admission (1/80, 1.3%), and one of 80 patients (1.3%) required postoperative admission to the intensive care unit. Various other clinical trials of SBRT have been conducted and reported results that were comparable to those of surgery7,8.
Mathematical models have been used to evaluate the complex responses in human physiological and pathological processes and have been extended to many areas9,10. Mathematical models were used to calculate the various reactions in medicine, vaccine efficacy, and for predicting the effects of anticancer drugs11–13. An ordinary differential equation (ODE) in mathematical models is a set of differential equations containing an independent variable and one or more derivatives for that variable. An ODE is the most extensive form for modeling dynamical systems in science and engineering10,14,15. In systems biology, many biological processes (e.g., gene regulation and signal transduction) can be modeled by reaction rate equations that express the rate of the production of one species as a function of the concentration of another species in the system11,13,14,16,17. Evaluations of tumor growth using an ODE-based mathematical model in radiation therapy of tumors with single irradiation have been also been reported18. With the use of a mathematical model based on an ODE, it becomes possible to evaluate the tumor volume as an output, determine the effect of radiation therapy on the tumor, and derive the optimal irradiation schedule, irradiation dose, and the tumor effect when radiation therapy is combined with drugs19–21.
In order to compare the biological effects of radiotherapy administered with different doses and differing numbers of radiation treatments, mainly the following equation, called the linear quadratic model (LQM), is used in current radiotherapy22,23. Comparisons of the effects of the LQM have been made with single doses in the range commonly used in radiotherapy up to approx. 8 Gy24,25. In the LQM, the surviving fraction (SF) is calculated as a function of the absorbed dose (D) in Gy with two coefficients, α and β, where α is the proportionality factor to D [Gy−1 ] and β is the proportionality factor to D2 [Gy−2]. However, the single fractionated dose exceeds 10 Gy in SBRT applied to lung cancers, and the actual cell survival rate may be higher than that predicted by the LQM when the dose is > 10 Gy26–29.
Some reports suggest that the LQM does not agree with the measured SF at high doses because the LQ curve bends continuously on a log-linear plot, which may interfere with extrapolation to high-dose fractionated treatments28,30,31. Various cell survival models have been proposed to solve this problem, microdosimetric kinetic model (MKM) was proposed that can predict the cell SF from physical doses based on domains, which are intracellular structures, for all types of radiation32. An MKM can accurately calculate cell viability even in the high-dose range by taking into account the radiation quality, the dose rate, and the cell DNA repair time33–37. There is a possibility of overestimating the effect of SF in the evaluation of LQMs, which may have a higher predictive at a single large dose since the calculation of cellular SF during irradiation by mathematical models based on ODEs is evaluated using LQM19–21. In addition, the LQM cannot account for sublethal damage repair (SLDR) affecting a tumor’s survival during irradiation, and there are few reports of the effect of the dose-delivery time used to irradiate a prescribed dose on the tumor cell volume in mathematical models based on ODEs.
We therefore created a new mathematical model by combining an ODE and an MKM, and we describe the model below. Based on our validation of the model, we propose that this combination model can be used to predict the tumor cell lethal effect of SBRT administered to NSCLC.
Methods
The SF calculations for 6MV photon beams using the MKM
The cell nucleus is divided into hundreds of independent regions, which are called domains in an MKM32. Irradiation of these domains causes a potential lethal lesion (PLL). PLLs are classified into the following four categories according to their variants. (1) Irreparable lethal lesions (LLs) that appear in the primary process (‘a’ is the conversion rate constant); (2) PLLs that are converted to LLs in the secondary process (‘bd’ is the conversion rate constant); (3) lesions that can be repaired in the primary process (‘c’ is the repair constant; and (4) lesions that do not become LLs for a certain period of time (tr) and then become LLs and cannot be repaired.
The MKM assumes that a PLL is a double-strand break in DNA. The number of PLLs were caused a single instantaneous irradiation. The number of PLLs per domain using the rate constants of conversion (a, bd, c) for transformations is calculated as:
1 |
2 |
3 |
Here, P is the number of PLLs in the domain and kd is the average number of PLLs per domain per dose [Gy−1] immediately after the irradiation. The parameter ‘z’ is the specific energy stored in the domain [Gy], and ‘t’ is the time [h] after irradiation, satisfying 0 < t < tr. The tr is assumed to be infinite, as discussed by Hawkins32. The repair rate (a + c) of the PLLs was equal to the primary repair rate λ calculated by the DNA repair half-life. The average number of LLs (Ln) per cell nucleus ias defined as follows:
4 |
While the corresponding parameters are.
5 |
6 |
7 |
Here, z is the specific energy [Gy] deposited in the domain, N is the number of domains, and A and B are coefficients. The parameter rd is the radius of the domain (0.5 μm), ρ is the density of the domain (1.0 g/cm3), D is the absorbed dose (Gy), and yD is the dose mean lineal energy (keV/μm). The parameters α0 and β0 were determined by a single instantaneous irradiation using the LQM.
The MKM has been improved to take into account various dose rates and irradiation schemes with photon beams and changes in the amount of DNA per nucleus during irradiation38. The irradiation time and irradiation interruption time were considered for the cell SF, and the changes in the amount of DNA in the cell cycle were ignored (α0 = constant, β0 = constant); by taking the limit and setting N to infinity, the expression in Eq. (4) is transformed as follows:
8 |
We thus transformed the Eq. (8) as follows:
9 |
10 |
Here, is the dose rate (Gy/min), and T is the dose-delivery time (min).
11 |
The parameter F is identified with the Lea–Catcheside time-factor G39. We used the α/β and DNA repair half-life T1/2 values of the parameters for calculating the DNA repair rate (a + c) value of two NSCLC cell lines, A549 and NCI-H460 (H460) to evaluate the radiation effect of SBRT28,29,40–42.
The dose mean lineal energy yD calculated by PHITS
The TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA) using a 6MV X-ray beam was modeled with the particle and heavy ion transport code system (PHITS)43. PHITS can deal with photons, electrons, positrons, neutrons, and heavy ions44. The phase space files of the Monte Carlo (MC) that we applied were provided by Varian Medical Systems. The following phase space files were created using BEAMnrc built on the EGSnrc platform, and these phase space files created by BEAMnrc were transferred to the PHITS system in which the dose calculations were performed to simulate the 6MV photon beams. A water-equivalent phantom (20 × 20 × 20 cm3) was created; the beam field size was 5 × 5 cm2 with source to phantom surface distance (SSD) = 90 cm, and the measurement point was 10 cm deep. The calculation width was 3 cm in the water-equivalent phantom. The photon and electron cut-off energies were set to 0.01 MeV, and the MC calculation was performed with a statistical error < 1.0%. The dose-mean lineal energy yD for MKM was calculated as:
12 |
13 |
where ε is the energy stored in the domain, l is the mean chord length, f(y) is the probability density of linear energy, and d(y) is the dose distribution of linear energy. The T-SED function of PHITS was used to calculate the dose mean lineal energy for 6 MV photon beams45,46. T-SED is a track structure T-SED calculates the distribution of energy imparted in a small area using formulas constructed based on the results of the analysis. The computationally derived yD values were used to evaluate the cell survival of the tumor in Eq. (4).
Tumor growth volume calculation using the ODE with mathematical model
We used the ODE with a multi-component mathematical model (MCM) that models growth by distinguishing the state and growth rate of tumor cells (active tumors and quiescent tumors, etc.) in this study20. The MCM distinguishes the tumor cells into active tumors, resting cells that can stop dividing and turn into active cells, and non-dividing cells, which are dead cells waiting to be excreted into the bloodstream. The effects on tumor cells were evaluated by combining the growth of tumor cells represented by the MCM with the mortality rate of cells expressed using the radiation calculation. The tumor cells were divided into the types T1, T2, and …Tm as active tumors in the MCM. The volume of the T1 tumor cells is V1; the volume of quiescent cells (TQ) is VQ, and the volume of the non-dividing cells (TND) is VND. The radiation affects active tumors (T1, T2,…Tm) and quiescent cells (TQ), but not non-dividing cells (TND). Because cells in the same tumor might be in different states and have different growth rates, such as active tumors and quiescent cells, the following model can be constructed using Eq. (14).
14 |
The value of K1 is constant related to the tumor growth rate and the environmental carrying capacity. The parameter pQ1 represents the probability that a TQ tumor cell is transformed into a T1 cell, and p1Q is the probability that a T1 tumor cell is transformed into a TQ cell; p1ND is the probability that a T1 tumor cell is transformed into a non-dividing cell TND in the blood. The growth of tumor cells represented by the MCM is modelled by Eq. (13). The volume of V2 is evaluated in the same way using Eq. (14). The volumes of Vm, VQ, and VND are expressed by the following equations, since the active tumor is divided into M pieces using Eqs. (15–17).
15 |
16 |
17 |
We used the MCM optimized with M = 2 to simplify the evaluation using this model. The percentages of T1, T2, and TQ tumor cells in the total tumor volume were defined as 50%, 20%, and 30%, respectively, with good agreement for the measurement value. MCM biological parameters were optimized and matched to measurement values of A549 and NCI-H460 (H460) cells using MATLAB software with the SimBiology toolbox47,48.
The effect of SBRT on the tumor volume using the mathematical model combined with the MKM
The LQM has been used to calculate the cell lethal effect of photon beams19–21. In the present study, to more accurately assess the cell lethal effects of SBRT, we evaluated the cell lethal effects using the MKM instead of the LQM.
18 |
The lethal effects of radiation on the tumors were calculated in the model using the MKM, and Eq. (18) was converted to ODE format (Eq. (19)).
19 |
Here, is the dose rate of radiation, and V is the volume of the tumor cells. The combination of tumor cell growth as indicated by the MCM and cell lethality as indicated by the radiological calculation yields the tumor cell volume calculation in SBRT (Eq. (20)).
20 |
Finally, to simulate fractionated irradiation in SBRT, the following equation was defined:
21 |
V1i, VQi, and Di are the volume and absorbed dose of the i-th tumor cell at V1, VQ, and D, respectively. N is the total number of radiotherapy fractions. The prescribed doses in this study were 48 Gy/4 fr and 54 Gy/3 fr, based on the conditions of clinical trials of SBRT for lung cancer49,50. The tumor volume in the fractional irradiation of V2, VQ, and VND was similarly calculated using Eq. (21). Figure 1 showed the MCM simulates combined with MKM to evaluate the effect of SBRT for tumor growth volume.
The dose rate is 3 Gy/min, and V is the volume of the tumor cells, which represents the total tumor volume of V1, V2, and VQ combined, defined as 500, 1000, and 1500 cm3 in this study. The tinter was set to 1 [day] in this study since tinter represents the time interval [days] of the fractionated dose (12 Gy or 18 Gy). The tintra represents the dose delivery time per one fractionated dose. Using the MKM instead of the LQM enabled the calculation of the effect of the dose rate to be taken into account.
In addition to the tintra derived from the relationship between the absorbed dose per fraction and the dose rate, we defined the tintra as 1, 5, 10, 30, and 60 min, and we then evaluated the effect of prolonging the dose delivery time tintra on the tumor volume. The first irradiation was defined as Time = 0 [day], the third irradiation, the final irradiation of 54 Gy/3 fr, was defined as Time = 2 [day], and the fourth irradiation, the final irradiation of 48 Gy/4 fr, was defined as Time = 3 [day]. We used the ratio of the tumor volume at 1 day after the end of the irradiation to the initial tumor volume to define the radiation effectiveness value (REV) in order to evaluate the effect of SBRT on the two NSCLC cell lines, A549 and H460.
Results
Comparison of the measured tumor volume and calculated tumor volume by MCM in A549 and H460 NSCLC cells
Figure 2 shows the measured values of A549 and H460 and the tumor growth volume calculated using the MCM. The parameters of the MCM for tumor growth volume are given in Table 1. The calculated results of the MCM for tumor volume evolution in time showed good agreement with the measurement values with both cell lines.
Table 1.
Parameter | A549 | H460 |
---|---|---|
0.86 | 0.76 | |
0.50 | 0.50 | |
1397 | 757 | |
1174 | 1199 | |
0.1 | 0.1 | |
0.2 | 0.2 | |
0.2 | 0.2 | |
0.1 | 0.1 | |
0.2 | 0.2 | |
0.2 | 0.2 | |
0.09 | 0.09 | |
0.4 | 0.4 |
Comparison of the surviving fraction (SF) for the A549 and H460 cells predicted by the LQM and MKM models
The comparison of calculated SF by LQM and MKM for the measured tumor SF from irradiation of A549 and H460 cells were shown (Fig. 3). In the high-dose region (> 12 Gy), the LQM underestimate the SF compared to measured values, whereas the MKM calculations show good agreement in the high-dose region. The parameters of the MKM for the tumor SF calculation are given in Table 2. The calculated cell viability with LQM and MKM for the measured cell viability with irradiation in A549 and H460 cells are shown (Fig. 3).
Table 2.
Parameter | A549 | H460 |
---|---|---|
0.19 | 0.21 | |
0.37 | 0.16 | |
0.30 | 0.30 | |
0.06 | 0.07 | |
0.02 | 0.03 | |
0.15 | 0.15 | |
2.10 | 1.51 | |
2.38 ± 0.01 | 2.38 ± 0.01 | |
3.0 | 3.0 | |
4.0 (12 Gy), 6.0 (18 Gy) | 4.0 (12 Gy), 6.0 (18 Gy) | |
1.0 | 1.0 |
The evaluation of effect of SBRT on tumor volumes using the MCM combined with the LQM and the MKM
A combined MCM and LQM or MKM model was used to evaluate the impact of SBRT on the tumor volume. The effects of the uses of the LQM and MKM on the tumor volume in SBRT are illustrated in Fig. 4a,b. The REVs for A549 cells on 500, 1000, 2000 cm3 using the LQM were 94.64%, 94.98%, and 95.53%, respectively (Table 3) with SBRT at 48 Gy/4 fr. The REVs using the MKM were 89.73%, 90.66%, and 92.05%, respectively. The REVs for A549 cells on 500, 1000, 2000 cm3 using the LQM were 99.21%, 99.22%, and 99.25%, respectively (Table 3) in 54 Gy/3 fr SBRT. The REVs using the MKM were 96.97%, 97.06%, and 97.23%, respectively. The REVs obtained with the MKM were lower than those obtained with the LQM, and the difference in REVs between the LQM and the MKM resulted in a smaller difference when the SBRT dose was 54 Gy/3 fr. In addition, the H460 cells have higher REV values than A549 cells in each of the cases (Table 3).
Table 3.
NSCLC cell line | Model, dose/fx | REV, (%) | ||
---|---|---|---|---|
Volume, (cm3) | 500 | 1000 | 2000 | |
A549 | LQM (48 Gy/4 fr) | 94.64 | 94.98 | 95.53 |
MKM (48 Gy/4 fr) | 89.73 | 90.66 | 92.05 | |
H460 | LQM (48 Gy/4 fr) | 95.89 | 96.13 | 96.52 |
MKM (48 Gy/4 fr) | 93.16 | 93.69 | 94.51 | |
A549 | LQM (54 Gy/3 fr) | 99.21 | 99.22 | 99.25 |
MKM (54 Gy/3 fr) | 96.97 | 97.06 | 97.23 | |
H460 | LQM (54 Gy/3 fr) | 99.34 | 99.35 | 99.37 |
MKM (54 Gy/3 fr) | 97.73 | 97.79 | 97.91 |
The impact of varying the V1, V2 and VQ ratio on tumor volume in SBRT
To determine its effect on the REVs in SBRT, we varied the ratios of V1, V2, and VQ tumor cells for the total tumor volume. Figures 5 and 6 depicts the results of the varying the ratio of V1 and V2 on the REVs. The percentage of VQ in the total tumor volume was fixed (30%, 500 cm3, 1000 cm3, and 2000 cm3) and we varied the ratio of V1–V2 at 10%, 20%, 35%, and 60% to evaluate the REVs. Table 4 summarizes the effects of varying the V1, V2, and VQ ratios for the REVs in SBRT (48 Gy/4 fr and 54 Gy/3 fr). The REVs on 500 cm3 initial tumor volume in 48 Gy/4 fr of A549 cells with 20% V1 (100 cm3) 50% V2 (250 cm3) 30% VQ (150 cm3), 35% V1 (100 cm3) 35% V2 (100 cm3) 30% VQ (800 cm3), and 60% V1 (300 cm3) 10% V2 (50 cm3) 30% VQ (150 cm3) were 88.53%, 88.98%, and 90.41%, respectively (Table 4). The corresponding values with 54 Gy/3 fr were 95.14%, 96.03%, and 97.63%, respectively. In the 48 Gy/4 fr and 54 Gy/3 fr SBRT, the highest REVs were observed for both A549 and H460 cells with a larger ratio of V1 in the total tumor volume on 500, 1000, and 2000 cm3. In addition, the tendency for an increase in the ratio of V1 to increase the REVs were greater for the 54 Gy/3 fr compared to the 48 Gy/4 fr (Table 4).
Table 4.
NSCLC cell line | Model, dose/fx | REV, (%) | ||
---|---|---|---|---|
Volume, (cm3) | 500 | 1000 | 2000 | |
A549 | 20% V1 50% V2 30% VQ (48 Gy/4 fr) | 88.53 | 89.60 | 91.20 |
35% V1 35% V2 30% VQ (48 Gy/4 fr) | 88.98 | 89.89 | 91.32 | |
60% V1 10% V2 30% VQ (48 Gy/4 fr) | 90.41 | 91.45 | 92.91 | |
10% V1 60% V2 30% VQ (48 Gy/4 fr) | 88.41 | 89.67 | 91.47 | |
10% V1 10% V2 80% VQ (48 Gy/4 fr) | 85.71 | 87.21 | 89.44 | |
20% V1 20% V2 60% VQ (48 Gy/4 fr) | 86.35 | 87.73 | 89.79 | |
H460 | 20% V1 50% V2 30% VQ (48 Gy/4 fr) | 89.00 | 90.16 | 91.87 |
35% V1 35% V2 30% VQ (48 Gy/4 fr) | 90.95 | 91.72 | 92.93 | |
60% V1 10% V2 30% VQ (48 Gy/4 fr) | 94.80 | 95.27 | 95.93 | |
10% V1 60% V2 30% VQ (48 Gy/4 fr) | 87.84 | 89.33 | 91.41 | |
10% V1 10% V2 80% VQ (48 Gy/4 fr) | 88.26 | 89.54 | 91.41 | |
20% V1 20% V2 60% VQ (48 Gy/4 fr) | 88.78 | 89.96 | 91.69 | |
A549 | 20% V1 50% V2 30% VQ (54 Gy/3 fr) | 95.14 | 95.40 | 95.84 |
35% V1 35% V2 30% VQ (54 Gy/3 fr) | 96.03 | 96.18 | 96.46 | |
60% V1 10% V2 30% VQ (54 Gy/3 fr) | 97.63 | 97.71 | 97.85 | |
10% V1 60% V2 30% VQ (54 Gy/3 fr) | 94.58 | 94.93 | 95.50 | |
10% V1 10% V2 80% VQ (54 Gy/3 fr) | 94.70 | 94.97 | 95.44 | |
20% V1 20% V2 60% VQ (54 Gy/3 fr) | 94.96 | 95.21 | 95.64 | |
H460 | 20% V1 50% V2 30% VQ (54 Gy/3 fr) | 95.31 | 95.57 | 96.02 |
35% V1 35% V2 30% VQ (54 Gy/3 fr) | 96.49 | 96.64 | 96.89 | |
60% V1 10% V2 30% VQ (54 Gy/3 fr) | 98.58 | 98.61 | 98.68 | |
10% V1 60% V2 30% VQ (54 Gy/3 fr) | 94.55 | 94.91 | 95.51 | |
10% V1 10% V2 80% VQ (54 Gy/3 fr) | 95.33 | 95.58 | 96.01 | |
20% V1 20% V2 60% VQ (54 Gy/3 fr) | 95.56 | 95.78 | 96.17 |
Figure 7a,b illustrates the effect on the REVs of changing the ratio of VQ. The REV in 48 Gy/4 fr of A549 with 10% V1 (50 cm3) 10% V2 (50 cm3) 80% VQ (400 cm3) on 500 cm3 initial tumor volume was 85.71% (Table 4). The corresponding values with 20% V1 (100 cm3) 20% V2 (100 cm3) 60% VQ (300 cm3) on 500 cm3 initial tumor volume was 86.35% (Table 4). The higher the VQ ratio resulted in no significant effect on REV values. The effect of the VQ ratio on the REV was the same for the H460 cells and 54 Gy/3 fr.
The effect of the dose delivery time per one fractionated dose tintra for REV in SBRT
Figure 8a shows the effect of changing the dose delivery time per one fractionated dose tintra on the REV in A549 and H460 cells irradiated at 48 Gy/4 fr. The REVs of the A549 cells with 1 and 60 min tintra were 94.93% and 79.00% for 500 cm3, respectively (Table 5), and 95.75% and 85.46% for 2000 cm3, respectively. The REVs of the H460 cells with 1 and 60 min tintra were 96.39% and 88.80% for 500 cm3, respectively, and 96.91% and 91.59% for 2000 cm3, respectively. Figure 8b illustrates the effect of extending the dose delivery time per one fractionated dose tintra on the REVs for A549 and H460 cells irradiated at 54 Gy/3 fr. The REVs of the A549 cells with 1 and 60 min tintra were 99.15% and 92.37% for 500 cm3, respectively (Table 5), and 99.19% and 93.49% for 2000 cm3, respectively. The REVs of the H460 cells with 1 and 60 min tintra were 99.35% and 95.25% for 500 cm3, respectively, and 99.38% and 95.81% for 2000 cm3, respectively. The REVs were significantly decreased with the increase in the dose delivery time tintra; in addition, the smaller the tumor volume, the greater the effect of increasing the tintra was. The effect of the extended irradiation time on the REV reduction was smaller for 54 Gy/3 fr compared to 48 Gy/4 fr.
Table 5.
NSCLC cell line | Model, dose/fx | REV, (%) | ||
---|---|---|---|---|
Volume, (cm3) | 500 | 1000 | 2000 | |
A549 | 1 min (48 Gy/4 fr) | 94.93 | 95.24 | 95.75 |
10 min (48 Gy/4 fr) | 88.10 | 89.27 | 90.98 | |
30 min (48 Gy/4 fr) | 84.25 | 86.05 | 88.55 | |
60 min (48 Gy/4 fr) | 79.00 | 81.79 | 85.46 | |
H460 | 1 min (48 Gy/4 fr) | 96.39 | 96.58 | 96.91 |
10 min (48 Gy/4 fr) | 92.87 | 93.44 | 94.31 | |
30 min (48 Gy/4 fr) | 91.36 | 92.13 | 93.27 | |
60 min (48 Gy/4 fr) | 88.80 | 89.95 | 91.59 | |
A549 | 1 min (54 Gy/3 fr) | 99.15 | 99.16 | 99.19 |
10 min (54 Gy/3 fr) | 96.59 | 96.70 | 96.91 | |
30 min (54 Gy/3 fr) | 94.87 | 95.09 | 95.47 | |
60 min (54 Gy/3 fr) | 92.37 | 92.79 | 93.49 | |
H460 | 1 min (54 Gy/3 fr) | 99.35 | 99.36 | 99.38 |
10 min (54 Gy/3 fr) | 97.51 | 97.59 | 97.72 | |
30 min (54 Gy/3 fr) | 96.58 | 96.70 | 96.91 | |
60 min (54 Gy/3 fr) | 95.25 | 95.45 | 95.81 |
Discussion
In this study, we evaluated the effect of two different prescribed doses of SBRT on NSCLC cells by combining an MCM, which calculates tumor growth, and the LQM or the MKM, which calculate cell lethality from radiotherapy. As suggested in earlier studies26–31, there is a possibility of overestimating the SF in the high-dose range > 10 Gy when the LQM is used, suggesting the possibility of good SF prediction by using the MKM as reported (Fig. 3)37,38,51,52. In the present study therefore, the REVs for A549 and H460 cells had larger values for the LQM compared to the MKM: up to 4.9% and 2.7% higher at 48 Gy/4fr and 2.2% and 1.6% higher at 54 Gy/3fr (Table 3). The reason for the larger difference between the LQM and MKM REV in the A549 cells is thought to be that the difference in calculated SFs between the LQM and the MKM in the A549 cells was larger than that in the H460 cells (Fig. 3). In the case of 54 Gy/3 fr, the fractionated dose is larger than that of 48 Gy/4fr, which might explain the smaller difference in REV reduction between the LQM and MKM models, as shown in Table 3. A mathematical model combined with an MKM based on ordinary differential equations could thus be used to more accurately calculate the tumor volume for NSCLC in SBRT.
Figures 5 and 6 showed the effect of varying the ratio of V1, V2 on the REV. The difference in the REVs at 48 Gy/4 fr was up to 4.7% for A549 cells and up to 6.5% for H460 cells at an initial tumor volume of 500 cm3 (Table 4), and the maximum was 3.1% for A549 cells and 4.0% for H460 cells at an initial tumor volume of 500 cm3 at 54 Gy/3 fr. The greater the percentage of V1 in the total tumor volume, the lower the REV was. The reason for this might be that V1 represents the volume of active tumor T1, which has a smaller α/β value compared to active tumor T2 (Table 1). In radiobiology, the effect is higher for a larger fractionated dose when the α/β ratio is small53.
The change in the percentage of quiescent cells TQ (VQ) also affected the REV (Table 4). The low radiosensitivity of quiescent cells compared to active tumor cells54. The advanced tumors have quiescent cells that grow slowly, and that the growth of human solid tumors depends not only on rapidly growing cancer cells, but also on their continued production55. Our comparison of the impact of V1 and V2 of active tumors and that of VQ of quiescent tumors as a ratio of the total tumor volume on the REV revealed that V1 and V2 had a greater impact on the REV. An estimated assessment of the ratio of active tumor to total tumor volume may therefore be needed for determining the REV; such an estimation is a task for a future study.
The flow cytometry was used to analyze the cell cycle distribution for the A549 and H460 lung cancer cell lines and observed that (1) the active tumors are highly dependent on the cell cycle, and (2) the rate of active tumors varies between tumor cell lines56. In addition, the tumor α/β values for the surviving fraction have been reported to vary even for the same type of lung cancer57. In the future, in order to optimize the parameters of the model, it will be necessary to collect experimental data and clinical data and optimize parameters such as V1, V2, VQ, and α/β.
There are several reports regarding the effect of a prolonged dose-delivery time (tintra) on tumor cell survival, and a prolonged dose-delivery time was reported to decrease the effect on tumors37,40,41,58. The delivered biologically effective dose (BED) levels were calculated due to alterations in the SLDR, and a loss of BED was observed on 13 Gy with the dose-delivery time of 35 min compared to the acute-exposure approach. The effect of a prolonged dose delivery time using the MKM on tumors showed an approximate 6% decrease in relative biological effectiveness at an irradiation time of 60 min40. In the present study, a tumor volume of 500 cc at 48 Gy/4 fr and an irradiation time of 60 min showed the greatest REV reduction at 15.9% in A549 cells (Table 5). On the other hand, H460 cells showed a 7.6% REV reduction under the same conditions. The greater impact of a time extension on the REV for A549 cells compared to H460 cells might be due to the faster DNA repair time for A549 cells and the greater impact of SLDR (Table 2).
We suspect that the reason for the smaller REV reductions in both A549 and H460 cells at 54 Gy/3 fr compared to 48 Gy/4 fr is that the cell lethal effect of the larger single fractionated dose is less affected by the SLDR effect of the longer dose-delivery time. Considering the results of the single irradiation in other studies that evaluated a prolonged dose-delivery time together with the results of the fractionated dose used in the present study, our results showed a decrease in the REV, similar to the previous studies. Few investigations have taken into account the dose-delivery time of each fraction in a fractionated dose and calculated the effect of the fractionated dose on the tumor. Our present findings suggest that (1) the dose-delivery time might have an effect on tumors even in a fractionated dose, and (2) it might be necessary to attempt to increase the dose-delivery time as quickly as possible.
This study has two limitations to address. The first limitation is our evaluation of the REV by SBRT using ODE to estimate tumor growth and the cell lethality calculation model MKM, without considering changes in the tumor cell environment after irradiation. The high single radiation doses delivered, such as SBRT, may induce elevated and possibly persistent tumor hypoxia in NSCLC tumors59. Changes in tumor oxygenation after irradiation may alter the tumor response to radiation therapy (may impact effectiveness of radiation therapy); this requires further investigation60,61. The second study limitation is that we set 1 day after irradiation as the time point for the evaluation of the REV. For accurate REV derivation, it will be necessary to evaluate the effect on tumors with using more time evaluation points, as in clinical trials8,46,47.
Conclusions
We evaluated the tumor volume considering a large fractionated dose and the dose-delivery time by combining the MKM with a mathematical model of tumor growth using ODEs in lung SBRT for non-small cell lung cancer. Our results demonstrated that the ratio of active tumor to the total tumor volume and the dose-delivery time both affect the tumor volume in SBRT.
Acknowledgements
This research was supported by grants from the Japan Society for the Promotion of Science (JSPS) KAKENHI, Nos. 19K17227, 20K16819, 21K07722, and 22K07792.
Author contributions
All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by Hisashi Nakano, Takehiro Shiinoki, Satochi Tanabe, Satoru Utsunomiya, and Takeshi Takizawa. The first draft of the manuscript was written by Hisashi Nakano, Takehiro Shiinoki and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Data availability
The data that support the findings of this study are available from corresponding author but restrictions apply to the availability of these data, which were used under license for the current study, and so are not publicly available. Data are however available from the authors upon reasonable request and with permission of corresponding author.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Chang JY, Balter PA, Dong L, Yang Q, Liao Z, Jeter M, et al. Stereotactic body radiation therapy in centrally and superiorly located stage I or isolated recurrent non-small-cell lung cancer. Int. J. Radiat. Oncol. Biol. Phys. 2008;72:967–971. doi: 10.1016/j.ijrobp.2008.08.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Onishi H, Araki T, Shirato H, Nagata Y, Hiraoka M, Gomi K, et al. Stereotactic hypofractionated high-dose irradiation for stage I nonsmall cell lung carcinoma: Clinical outcomes in 245 subjects in a Japanese multiinstitutional study. Cancer. 2004;101:1623–1631. doi: 10.1002/cncr.20539. [DOI] [PubMed] [Google Scholar]
- 3.Palma D, Visser O, Lagerwaard FJ, Belderbos J, Slotman BJ, Senan S. Impact of introducing stereotactic lung radiotherapy for elderly patients with stage I non-small cell lung cancer: A population-based time-trend analysis. J. Clin. Oncol. 2010;28:5153–5159. doi: 10.1200/JCO.2010.30.0731. [DOI] [PubMed] [Google Scholar]
- 4.Milano MT, Constine LS, Okunieff P. Normal tissue toxicity after small field hypofractionated stereotactic body radiation. Radiat. Oncol. 2008;3:36. doi: 10.1186/1748-717X-3-36. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Schneider BJ, Daly ME, Kennedy EB, Antonoff MB, Broderick S, Feldman J, et al. Stereotactic body radiotherapy for early-stage non-small-cell lung cancer: American Society of Clinical Oncology Endorsement of the American Society for Radiation Oncology Evidence-Based Guideline. J. Clin. Oncol. 2018;36(7):710–719. doi: 10.1200/JCO.2017.74.9671. [DOI] [PubMed] [Google Scholar]
- 6.Chang JY, Mehran RJ, Feng L, Verma V, Liao Z, Welsh JW, et al. Stereotactic ablative radiotherapy for operable stage I non-small-cell lung cancer (revised STARS): Long-term results of a single-arm, prospective trial with prespecified comparison to surgery. Lancet Oncol. 2021;22(10):1448–1457. doi: 10.1016/S1470-2045(21)00401-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Timmerman RD, Hu C, Michalski JM, Bradley JC, Galvin J, Johnstone DM, Choy H. Long-term results of stereotactic body radiation therapy in medically inoperable stage I non-small cell lung cancer. JAMA Oncol. 2018;4(9):1287–1288. doi: 10.1001/jamaoncol.2018.1258. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Kimura T, Nagata Y, Harada H, Hayashi S, Matsuo Y, Takanaka T, et al. Phase I study of stereotactic body radiation therapy for centrally located stage IA non-small cell lung cancer (JROSG10-1) Int. J. Clin. Oncol. 2017;22(5):849–856. doi: 10.1007/s10147-017-1125-y. [DOI] [PubMed] [Google Scholar]
- 9.Michor F, Beal K. Improving cancer treatment via mathematical modeling: surmounting the challenges is worth the effort. Cell. 2015;163(5):1059–1063. doi: 10.1016/j.cell.2015.11.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Jarrett AM, Shah A, Bloom MJ, McKenna MT, Hormuth DA, Yankeelov TE, et al. Experimentally-driven mathematical modeling to improve combination targeted and cytotoxic therapy for HER2+ breast cancer. Sci. Rep. 2019;9(1):12830. doi: 10.1038/s41598-019-49073-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Sun X, Bao J, Shao Y. Mathematical modeling of therapy-induced cancer drug resistance: connecting cancer mechanisms to population survival rates. Sci. Rep. 2016;6(1):22498. doi: 10.1038/srep22498. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Diagne ML, Rwezaura H, Tchoumi SY, Tchuenche JM. A mathematical model of COVID-19 with vaccination and treatment. Comput. Math. Methods Med. 2021;2021:1250129. doi: 10.1155/2021/1250129. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Milberg O, Gong C, Jafarnejad M, Bartelink IH, Wang B, Vicini P, et al. A QSP model for predicting clinical responses to monotherapy, combination and sequential therapy following CTLA-4, PD-1, and PD-L1 checkpoint blockade. Sci Rep. 2019;9(1):11286. doi: 10.1038/s41598-019-47802-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Murphy H, Jaafari H, Dobrovolny HM. Differences in predictions of ODE models of tumor growth: A cautionary example. BMC Cancer. 2016;16:163. doi: 10.1186/s12885-016-2164-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Yin A, Moes DJAR, van Hasselt JGC, Swen JJ, Guchelaar HJ. A review of mathematical models for tumor dynamics and treatment resistance evolution of solid tumors. CPT Pharmacomet. Syst. Pharmacol. 2019;8(10):720–737. doi: 10.1002/psp4.12450. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Hasdemir D, Hoefsloot HC, Smilde AK. Validation and selection of ODE based systems biology models: How to arrive at more reliable decisions. BMC Syst. Biol. 2015;9:32. doi: 10.1186/s12918-015-0180-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Stapor P, Schmiester L, Wierling C, Merkt S, Pathirana D, Lange BMH, Weindl D, Hasenauer J. Mini-batch optimization enables training of ODE models on large-scale datasets. Nat. Commun. 2022;13(1):34. doi: 10.1038/s41467-021-27374-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Watanabe Y, Dahlman EL, Leder KZ, Hui SK. A mathematical model of tumor growth and its response to single irradiation. Theor. Biol. Med. Model. 2016;13:6. doi: 10.1186/s12976-016-0032-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Kosinsky Y, Dovedi SJ, Peskov K, Voronova V, Chu L, Tomkinson H, et al. Radiation and PD-(L)1 treatment combinations: Immune response and dose optimization via a predictive systems model. J. Immunother. Cancer. 2018;6(1):17. doi: 10.1186/s40425-018-0327-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Hong WS, Wang SG, Zhang GQ. Lung cancer radiotherapy: Simulation and analysis based on a multicomponent mathematical model. Comput. Math. Methods Med. 2021;2021:6640051. doi: 10.1155/2021/6640051. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Hong WS, Zhang GQ. Simulation analysis for tumor radiotherapy based on three-component mathematical models. J. Appl. Clin. Med. Phys. 2019;20(3):22–26. doi: 10.1002/acm2.12516. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.McMahon SJ. The linear quadratic model: Usage, interpretation and challenges. Phys. Med. Biol. 2018;64(1):01TR01. doi: 10.1088/1361-6560/aaf26a. [DOI] [PubMed] [Google Scholar]
- 23.Unkel S, Belka C, Lauber K. On the analysis of clonogenic survival data: Statistical alternatives to the linear-quadratic model. Radiat. Oncol. 2016;11:11. doi: 10.1186/s13014-016-0584-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Nakano H, Minami K, Yagi M, Imaizumi H, Otani Y, Inoue S, et al. Radiobiological effects of flattening filter-free photon beams on A549 non-small-cell lung cancer cells. J. Radiat. Res. 2018;59(4):442–445. doi: 10.1093/jrr/rry041. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Franken NAP, Oei AL, Kok HP, Rodermond HM, Sminia P, Crezee J, et al. Cell survival and radiosensitisation: Modulation of the linear and quadratic parameters of the LQ model (Review) Int. J. Oncol. 2013;42(5):1501–1515. doi: 10.3892/ijo.2013.1857. [DOI] [PubMed] [Google Scholar]
- 26.Sheu T, Molkentine J, Transtrum MK, Buchholz TA, Withers HR, Thames HD, et al. Use of the LQ model with large fraction sizes results in underestimation of isoeffect doses. Radiother. Oncol. 2013;109:21–25. doi: 10.1016/j.radonc.2013.08.027. [DOI] [PubMed] [Google Scholar]
- 27.Kirkpatrick JP, Meyer JJ, Marks LB. The linear quadratic model is inappropriate to model high dose per fraction effects in radiosurgery. Semin. Radiat. Oncol. 2008;18:240–243. doi: 10.1016/j.semradonc.2008.04.005. [DOI] [PubMed] [Google Scholar]
- 28.Park C, Papiez L, Zhang S, Story M, Timmerman RD. Universal survival curve and single fraction equivalent dose: Useful tools in understanding potency of ablative radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 2008;70(3):847–852. doi: 10.1016/j.ijrobp.2007.10.059. [DOI] [PubMed] [Google Scholar]
- 29.Jiang L, Xiong XP, Hu CS, Ou ZL, Zhu GP, Ying HM. In vitro and in vivo studies on radiobiological effects of prolonged fraction delivery time in A549 cells. J. Radiat. Res. 2013;54(2):230–234. doi: 10.1093/jrr/rrs093. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Astrahan M. Some implications of linear-quadratic-linear radiation dose-response with regard to hypofractionation. Med. Phys. 2008;35(9):4161–4172. doi: 10.1118/1.2969065. [DOI] [PubMed] [Google Scholar]
- 31.Date H, Wakui K, Sasaki K, Kato T, Nishioka T. A formulation of cell surviving fraction after radiation exposure. Radiol. Phys. Technol. 2014;7(1):148–157. doi: 10.1007/s12194-013-0244-z. [DOI] [PubMed] [Google Scholar]
- 32.Hawkins RB. A microdosimetric-kinetic model of cell death from exposure to ionizing radiation of any LET, with experimental and clinical applications. Int. J. Radiat. Biol. 1996;69:739–755. doi: 10.1080/095530096145481. [DOI] [PubMed] [Google Scholar]
- 33.Sato T, Matsuya Y, Hamada N. Microdosimetric modeling of relative biological effectiveness for skin reactions: Possible linkage between in vitro and in vivo data. Int. J. Radiat. Oncol. Biol. Phys. 2022;S0360–3016(22):00418–427. doi: 10.1016/j.ijrobp.2022.05.010. [DOI] [PubMed] [Google Scholar]
- 34.Sato T, Hashimoto S, Inaniwa T, Takada K, Kumada H. Implementation of simplified stochastic microdosimetric kinetic models into PHITS for application to radiation treatment planning. Int. J. Radiat. Biol. 2021;97(10):1450–1460. doi: 10.1080/09553002.2021.1956003. [DOI] [PubMed] [Google Scholar]
- 35.Inaniwa T, Suzuki M, Furukawa T, Kase Y, Kanematsu N, Shirai T, Hawkins RB. Effects of dose-delivery time structure on biological effectiveness for therapeutic carbon-ion beams evaluated with microdosimetric kinetic model. Radiat. Res. 2013;180(1):44–59. doi: 10.1667/RR3178.1. [DOI] [PubMed] [Google Scholar]
- 36.Parisi A, Furutani KM, Beltran CJ. On the calculation of the relative biological effectiveness of ion radiation therapy using a biological weighting function, the microdosimetric kinetic model (MKM) and subsequent corrections (non-Poisson MKM and modified MKM) Phys. Med. Biol. 2022;67(9):095014. doi: 10.1088/1361-6560/ac5fdf. [DOI] [PubMed] [Google Scholar]
- 37.Matsuya Y, Tsutsumi K, Sasaki K, Date H. Evaluation of the cell survival curve under radiation exposure based on the kinetics of lesions in relation to dose-delivery time. J. Radiat. Res. 2015;56(1):90–99. doi: 10.1093/jrr/rru090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Matsuya Y, Tsutsumi K, Sasaki K, Yoshii Y, Kimura T, Date H. Modeling cell survival and change in amount of DNA during protracted irradiation. J. Radiat. Res. 2017;58(3):302–312. doi: 10.1093/jrr/rrw110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Brenner DJ. The linear-quadratic model is an appropriate methodology for determining isoeffective doses at large doses per fraction. Semin. Radiat. Oncol. 2008;18:234–239. doi: 10.1016/j.semradonc.2008.04.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Nakano H, Kawahara D, Ono K, Akagi Y, Hirokawa Y. Effect of dose-delivery time for flattened and flattening filter-free photon beams based on microdosimetric kinetic model. PLoS ONE. 2018;13(11):e0206673. doi: 10.1371/journal.pone.0206673. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Nakano H, Kawahara D, Tanabe S, Utsunomiya S, Takizawa T, Sakai M, et al. Radiobiological effects of the interruption time with Monte Carlo simulation on multiple fields in photon beams. J. Appl. Clin. Med. Phys. 2020;21(12):288–294. doi: 10.1002/acm2.13110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Kawahara D, Nakano H, Saito A, Ozawa S, Nagata Y. Dose compensation based on biological effectiveness due to interruption time for photon radiation therapy. Br. J. Radiol. 2020;93(1111):20200125. doi: 10.1259/bjr.20200125. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Sato T, Iwamoto Y, Hashimoto S, Ogawa T, Furuta T, Abe S, et al. Features of particle and heavy ion transport code system (PHITS) version 3.02. J. Nucl. Sci. Technol. 2018;55(5–6):684–690. doi: 10.1080/00223131.2017.1419890. [DOI] [Google Scholar]
- 44.Furuta T, Sato T. Medical application of particle and heavy ion transport code system PHITS. Radiol. Phys. Technol. 2021;14(3):215–225. doi: 10.1007/s12194-021-00628-0. [DOI] [PubMed] [Google Scholar]
- 45.Sato T, Watanabe R, Niita K. Development of a calculation method for estimating specific energy distribution in complex radiation fields. Radiat. Prot. Dosim. 2006;122(1–4):41–45. doi: 10.1093/rpd/ncl407. [DOI] [PubMed] [Google Scholar]
- 46.Sato T, Kase Y, Watanabe R, Niita K, Sihver L. Biological dose estimation for charged-particle therapy using an improved PHITS code coupled with a microdosimetric kinetic model. Radiat Res. 2009;171(1):107–117. doi: 10.1667/RR1510.1. [DOI] [PubMed] [Google Scholar]
- 47.Rhyu JJ, Yun JW, Kwon E, Che JH, Kang BC. Dual effects of human adipose tissue-derived mesenchymal stem cells in human lung adenocarcinoma A549 xenografts and colorectal adenocarcinoma HT-29 xenografts in mice. Oncol. Rep. 2015;34(4):1733–1744. doi: 10.3892/or.2015.4185. [DOI] [PubMed] [Google Scholar]
- 48.Chougule MB, Patel A, Sachdeva P, Jackson T, Singh M. Enhanced anticancer activity of gemcitabine in combination with noscapine via antiangiogenic and apoptotic pathway against non-small cell lung cancer. PLoS ONE. 2011;6(11):e27394. doi: 10.1371/journal.pone.0027394. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Nagata Y, Takayama K, Matsuo Y, Norihisa Y, Mizowaki T, Sakamoto T, et al. Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame. Int. J. Radiat. Oncol. Biol. Phys. 2005;63(5):1427–1431. doi: 10.1016/j.ijrobp.2005.05.034. [DOI] [PubMed] [Google Scholar]
- 50.Timmerman RD, Paulus R, Pass HI, Gore EM, Edelman MJ, Galvin J, et al. Stereotactic body radiation therapy for operable early-stage lung cancer: Findings from the NRG oncology RTOG 0618 Trial. JAMA Oncol. 2018;4(9):1263–1266. doi: 10.1001/jamaoncol.2018.1251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Matsuya Y, Kimura T, Date H. Markov chain Monte Carlo analysis for the selection of a cell-killing model under high-dose-rate irradiation. Med. Phys. 2017;44(10):5522–5532. doi: 10.1002/mp.12508. [DOI] [PubMed] [Google Scholar]
- 52.Matsuya Y, Fukunaga H, Omura M, Date H. A model for estimating dose-rate effects on cell-killing of human melanoma after boron neutron capture therapy. Cells. 2020;9(5):1117. doi: 10.3390/cells9051117. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Miles EF, Lee WR. Hypofractionation for prostate cancer: A critical review. Semin. Radiat. Oncol. 2008;18(1):41–47. doi: 10.1016/j.semradonc.2007.09.006. [DOI] [PubMed] [Google Scholar]
- 54.Zhao L, Wu D, Mi D, Sun Y. Radiosensitivity and relative biological effectiveness based on a generalized target model. J. Radiat. Res. 2017;58(1):8–16. doi: 10.1093/jrr/rrw062. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Alves CP, Dey-Guha I, Kabraji S, Yeh AC, Talele NP, Solé X, et al. AKT1 low quiescent cancer cells promote solid tumor growth. Mol. Cancer Ther. 2018;17(1):254–263. doi: 10.1158/1535-7163.MCT-16-0868. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Neher TM, Bodenmiller D, Fitch RW, Jalal SI, Turchi JJ. Novel irreversible small molecule inhibitors of replication protein A display single-agent activity and synergize with cisplatin. Mol. Cancer Ther. 2011;10(10):1796–1806. doi: 10.1158/1535-7163.MCT-11-0303. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.van Leeuwen CM, Oei AL, Crezee J, Bel A, Franken NAP, Stalpers LJA, Kok HP. The alfa and beta of tumours: A review of parameters of the linear-quadratic model, derived from clinical radiotherapy studies. Radiat. Oncol. 2018;13(1):96. doi: 10.1186/s13014-018-1040-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Moutsatsos A, Kouris P, Zoros M, Athanasiou O, Koutsarnakis C, Pantelakos P, Pantelis E. On the effect of dose delivery temporal domain on the biological effectiveness of central nervous system CyberKnife radiosurgery applications: Theoretical assessment using the concept of biologically effective dose. Phys. Med. Biol. 2022;67(13):135004. doi: 10.1088/1361-6560/ac783b. [DOI] [PubMed] [Google Scholar]
- 59.Kelada OJ, Decker RH, Nath SK, Johung KL, Zheng MQ, Huang Y, et al. High single doses of radiation may induce elevated levels of hypoxia in early-stage non-small cell lung cancer tumors. Int. J. Radiat. Oncol. Biol. Phys. 2018;102(1):174–183. doi: 10.1016/j.ijrobp.2018.05.032. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Ressel A, Weiss C, Feyerabend T. Tumor oxygenation after radiotherapy, chemotherapy, and/or hyperthermia predicts tumor free survival. Int. J. Radiat. Oncol. Biol. Phys. 2001;49(4):1119–1125. doi: 10.1016/S0360-3016(00)01523-6. [DOI] [PubMed] [Google Scholar]
- 61.Hughes VS, Wiggins JM, Siemann DW. Tumor oxygenation and cancer therapy-then and now. Br J Radiol. 2019;92(1093):20170955. doi: 10.1259/bjr.20170955. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data that support the findings of this study are available from corresponding author but restrictions apply to the availability of these data, which were used under license for the current study, and so are not publicly available. Data are however available from the authors upon reasonable request and with permission of corresponding author.