Skip to main content
NPJ Microgravity logoLink to NPJ Microgravity
. 2023 Jul 28;9:58. doi: 10.1038/s41526-023-00306-y

The space cold atom interferometer for testing the equivalence principle in the China Space Station

Meng He 1,2, Xi Chen 1,, Jie Fang 1, Qunfeng Chen 1, Huanyao Sun 1, Yibo Wang 1, Jiaqi Zhong 1,3, Lin Zhou 1,3, Chuan He 1, Jinting Li 1,2, Danfang Zhang 1,2, Guiguo Ge 1,2, Wenzhang Wang 1,2, Yang Zhou 1,2, Xiao Li 1, Xiaowei Zhang 1, Lei Qin 1, Zhiyong Chen 1, Rundong Xu 1, Yan Wang 1, Zongyuan Xiong 1, Junjie Jiang 1,2, Zhendi Cai 1,2, Kuo Li 4, Guo Zheng 4, Weihua Peng 4, Jin Wang 1,3,5,, Mingsheng Zhan 1,3,5,
PMCID: PMC10382534  PMID: 37507455

Abstract

The precision of the weak equivalence principle (WEP) test using atom interferometers (AIs) is expected to be extremely high in microgravity environment. The microgravity scientific laboratory cabinet (MSLC) in the China Space Station (CSS) can provide a higher-level microgravity than the CSS itself, which provides a good experimental environment for scientific experiments that require high microgravity. We designed and realized a payload of a dual-species cold rubidium atom interferometer. The payload is highly integrated and has a size of 460mm×330mm×260mm. It will be installed in the MSLC to carry out high-precision WEP test experiment. In this article, we introduce the constraints and guidelines of the payload design, the compositions and functions of the scientific payload, the expected test precision in space, and some results of the ground test experiments.

Subject terms: Raman spectroscopy, Atomic and molecular physics, Optical manipulation and tweezers, Applied optics

Introduction

General relativity (GR) is a cornerstone of modern physics. Einstein’s equivalence principle (EEP) is one of the assumptions of GR and consists of three parts: the weak equivalence principle (WEP), local Lorentz invariance (LLI), and local position invariance (LPI). The WEP states that two objects with different materials and structures have the same acceleration in the same gravitational field.

GR describes gravity as a spacetime geometry, but gravity cannot be quantized by quantum mechanics (QM). Many physical theories (loop quantum gravity, noncommutative geometry, and the fifth force)13 have been proposed to solve the incompatibility between GR and QM. These theories generally require violation of the WEP. Therefore, high-precision tests of the WEP are important for identifying them and searching for the unified physics.

The WEP test is usually carried out by measuring the accelerations of two different objects in the same gravitational field. The inequality of the measured accelerations indicates a violation of the WEP. Testing of the WEP has a long history, and methods using Newtonian pendulum, torsion balance, free-fall experiment, Lunar Laser Ranging, or astronomical observation have been proposed and implemented to search for the boundary where the WEP is still valid48. The highest precision of the WEP test on the ground comes from the results of the torsion balance and Lunar Laser Ranging experiments. Both of those experiments had a precision of 1013 5,6.

Atom interferometers provide a method for testing the WEP using microscopic atoms. By measuring the differential acceleration of the two atomic clouds using dual-species AI, a high-precision WEP test can be realized. The first results of the WEP test based on AI came from S. Fray et al. in 2004, they measured the gravitational accelerations of 85Rb and 87Rb atoms and obtained a test precision of 107 9. Subsequently, various AI-based WEP test experiments were carried out1017. The test mass covers rubidium, potassium, strontium, etc. The highest test precision was obtained by P. Asenbaum et al. in 2020, they carried out an AI-based WEP experiment using ultracold atoms of the Rb isotope, and obtained a test precision of 101218. Testing the WEP using AI does not only improve the test precision but also extend the test category. This is because microscopic atoms can be prepared in different quantum states, such as spin or superposition states1921. The WEP test using these atomic states is a direct quantum test of the theory of gravity.

The microgravity environment has many advantages that the WEP test experiments of both macroscopic and microscopic test masses can benefit from. For macroscopic objects, the French Space Agency has carried out a satellite project called MICROSCOPE22. By measuring the differential accelerations of two concentric cylinders of platinum and titanium alloy, a WEP test precision of 1015 had been achieved22, and it is the highest test precision of the WEP up to now. For microscopic atoms, owing to zero gravity, an atomic interferometry in space can achieve a long interference time, thus significantly improving the measurement precision. Many AI-based WEP test projects in space have been proposed, including QUANTUS23, MAIUS24,25, ICE26,27, STE-QUEST28etc. The QUANTUS is a drop-tower project which is pre-research for satellite project. It has achieved 87Rb MOT29, 87Rb BEC30 and Mach-Zehnder interferometer31. The MAIUS is a sounding-rocket project. It has successfully prepared BEC24 and verified the coherence of BEC in microgravity25. ICE is a parabolic flight project, it has obtained the Ramsey fringes and realized a WEP test with precision of 104 using 87Rb and 39K atoms27. The STE-QUEST project is a satellite project proposed by the European Space Agency (ESA). Its scientific objective is to test the WEP using 87Rb and 41K atoms and achieve a test precision at the level of 1017. In addition to testing the WEP, AI in space can be also used to detect the gravitational wave and dark energy, projects like Q-WEP32, QTEST33, CAL34,35, BECCAL36, SAI37, SAGE38 have been proposed.

The China Space Station (CSS) will be in orbit for decades. Many scientific laboratory cabinets (SLCs) are arranged on the CSS to carry out various scientific experiments in space. The microgravity scientific laboratory cabinet (MSLC) is one of the SLCs, and it can achieve a microgravity level of 107g, which is much better than the CSS itself. This provides an ideal platform for scientific experiments that require a high microgravity. However, limited by the space and power supply of the cabinet, strict restrictions are imposed on the payload design.

Under such circumstances, we designed and achieved a compact dual-species AI payload that can work in MSLC. The scientific objective is to realize a WEP test with high precision. The payload uses rubidium isotopes as the test mass. The overall size of the payload is 460 mm × 330 mm × 260 mm, its weight is approximately 37 kg, and its peak power consumption is approximately 70 W. The payload was launched into the CSS by the TianZhou-5 spacecraft (TZ-5) on November 12, 2022. Then it was installed into the MSLC on December 10, 2022, and successfully powered on in the same day. The lifetime of the payload in orbit is expected to be 2 years.

The remainder of this paper is organized as follows. In method section, we introduce the constraints and guidelines of AI payload design, the detailed design of the scientific payload, including its composition and functions. In results and discussion section, we introduce the scientific experiment process in space, the expected test precision of the WEP test, and the experimental results of the ground test.

Methods

The scientific payload is installed in a magnetic suspension bench (MSB) which is inside the MSLC. The first problem we have to solve is finding a proper scheme that can achieve a relatively high test-precision and fit the design constraints.

Three-dimension velocity selection for achieving ultracold atoms

The most important advantage of microgravity for AI is that it can significantly increase the interference time. However, a long interference time implies a low expansion rate of the atomic cloud, which equivalently implies a low effective atomic ensemble temperature. For rubidium, if one wants the atomic cloud to expand to 1 cm (full width at half maximum) within 2.5 s, then the equivalent temperature is calculated to be 29nK.

The usual way for obtaining such a low temperature is to use the evaporative cooling method. However, both the magnetic trap and optical trap of the evaporative cooling scheme require a large amount of power consumption, which is far beyond the rated power consumption of the payload design. Therefore, we propose a three-dimensional (3D) velocity selection method to obtain an effective low atomic ensemble temperature. The basic idea is as follows: after the 3D-MOT cooling and polarization gradient cooling (PGC) processes, the atomic cloud expands freely, the velocity of the atomic cloud in the direction of the Raman laser is selected by Raman pulses with proper duration, and the velocities of the atomic cloud perpendicular to the direction of the Raman laser are selected by the detection area. Using this method, we can select the desired 3D atom velocity distribution at the cost of losing a certain number of atoms. This method employs only the traditional 3D cooling technique and does not require additional power consumption.

The experimental scheme of the velocity selection method and the corresponding coordinate frame are shown in Fig. 1. The cold atomic clouds after 3D cooling are localized in the center of the vacuum chamber, the Raman laser is reflected by a polarization beam splitter (PBS) and acts on the cold atomic clouds in the z-direction. After the Raman interference process, the fluorescence of the atomic clouds is excited by the 3D cooling laser beams, which propagate along the x-axis and in the y-z plane. The fluorescence is transmitted through the PBS and a four-lens imaging system and is imaged by a SCMOS camera. The velocity distribution of the atomic cloud in the z- direction is selected by the Raman laser pulse with a proper duration, and the velocity distribution of the atomic cloud in the x- and y-direction can be selected by the imaging range of the camera.

Fig. 1. Scheme of the velocity selection and velocity distribution.

Fig. 1

a Schematic diagram of the 3D velocity selection. b 1D velocity distribution of the atomic cloud before and after velocity selection. The number of atoms and temperature of the atomic cloud are N=5×108, Te=4μK before the velocity selection, and the parameters for the velocity selection are r0=0.5mm, l=0.5cm and t=2.5s.

First, we consider the velocity selection scheme in the one-dimensional (1D) case. Assuming that the temperature after the PGC process is Te, the average atomic cloud velocity and position are zero. The initial widths of the velocity and size distributions of the atomic cloud are v0 and r0, respectively, with v0=kBTe/mRb, where kB is the Boltzmann constant, and mRb is the mass of Rb atoms. The atomic cloud distribution after an evolving time t is

Fr,v,t=12πr0ervt2/(2r02)12πv0ev2/(2v02) 1

The selection range is (l,l), the velocity distribution is fv,t=llF(r,v,t)dr, the selection ratio of the atom number isβ1D=f(v,t)dv, and the effective temperature of the selected atomic cloud is Tsel1D=mRbv2fv,tdv/(β1DkB). When the distributions and selection ranges of the atomic cloud are isotropic, the 3D effective temperature and selection ratio are Tsel3D=3Tsel1D and β3D=β1D3.

For our typical experimental parameters, we have N=5×108, Te=4μK, r0=0.5mm, l=0.5cm and t=2.5s. Then the calculated selection ratio is β3D=5.2×104, and selected number of atoms is Nsel=2.6×105. The effective atomic temperature is Tsel1D=14nK. The 3D velocity selection method decreases the atomic cloud temperature by reducing the number of atoms. Therefore, to supply a sufficient number of atoms, the two-dimensional +(2D+)39 scheme was applied in the design of the payload.

Double-diffraction Raman interference scheme associated with the phase shear method

In the following of the article, we denote i = 1, 2 for the 85Rb and 87Rb atoms and the transition means the D2 line transition for the rubidium atom for simplicity, and F and F′ denote the hyperfine structure of the 5S1/2 ground state and 5P3/2 exited state, respectively.

In microgravity, the atomic cloud is at rest if its released velocity is zero. When the atomic cloud interacts with a Raman laser or Bragg laser, because of the degenerate of the energy states |ai, +ħkeff,i> and |ai, −ħkeff,i > , |ai > and |bi > represent the |F = 2, mF = 0> and | F = 3, mF = 0> ground states for 85Rb (|F = 1, mF = 0> and |F = 2, mF = 0> for 87Rb) as shown in Fig. 2, the double-diffraction process occurs spontaneously, where keff,ik1,ik2,i=k3,ik4,i is the effective wave vector, and km,i (m = 1, 2, 3, 4) is the wave vector. For our design, we choose the double-diffraction Raman scheme40 for the following reasons. First, the Raman transition is a type of internal state transition, which puts a lower requirement for the atomic temperature than the Bragg transition. Second, the end-state population of the interference can be detected by different internal states, which does not require a space separation fluorescence detection method. Third, the Raman laser was much easier to produce for our phase-modulation based optical system.

Fig. 2. Schematic diagram of the double-diffraction Raman interference.

Fig. 2

a Energy levels of the double-diffraction Raman transitions. b Interference loop of the double-diffraction Raman interference. |ai > and |bi > represent the ground states of |F = 2, mF = 0> and |F = 3, mF = 0> for 85Rb (|F = 1, mF = 0> and | F = 2, mF = 0> for 87Rb), |ci > is the excited state, Δi and δi are the single-photon and double-photon detuning.

The phase shear method is an effective way to extract the interference fringe41. It has advantages of obtaining interference fringes in a single measurement, eliminating noise from atom number fluctuations and detection laser, and greatly suppressing the dephasing effect caused by the rotation and gravity gradient. However, there are still some challenges in applying this method for our experiment, the main reason is the uncertainty of the rotational velocity of the MSB.

When the MSB is in the levitation mode, the rotation of the bench is influenced by the magnetic field and gravity gradient of the Earth. In addition, the noise and zero-point drift of its inertial measurement unit (IMU) gyroscope also result in residual control noise of the rotation. This causes uncertainty in the rotation, both for the magnitude and direction. The phase shear induced by the rotation is

ϕRot,i=4keff,iΩxvy,iT24keff,iΩyvx,iT2 2

where Ωx and Ωy are the rotation components of the bench, vx,i and vy,i are the velocity components of the atoms, T is the interference evolution time. Therefore, the direction of the interference fringe of the atomic cloud is always in the x-y plane. The best strategy is to detect the fringe in the z-direction, which coincides with the scheme of the 3D velocity selection method, as shown in Fig. 1.

In the detection stage, the Raman laser is turned off and a cooling laser is used to excite the fluorescence of the atomic cloud. A PBS is used to separate the Raman laser and fluorescence because they have to be in the same direction. The use of the PBS results in losing of half of the fluorescence intensity.

Rotation compensation scheme with a piezoelectric deflector

The MSB has a weak control of the rotation with a precision of about 0.5 mrad s−1. This can result in a fringe numbers variation of 0 to 20 over a 1 s interference time interval and a 1 cm detection range according to Eq. (2). If the rotation rate is close to zero, the phase shear of the atomic cloud will be too small to extract the phase shift, and if the rotation rate is too large, there will be too many fringe numbers in the limited detection range, which will decrease the contrast of the fringe owing to the initial size of the atomic cloud and the resolution of the imaging system.

In order to solve the problem, we used a closed-loop controlled piezoelectric deflector associated with an IMU module to compensate the residual rotation, the Raman laser reflecting mirror is mounted on the deflector as shown in Fig. 1 The tilted angles of the deflector can be controlled during the Raman process according to the rotation measured by the IMU. Considering the tilt angles of the deflector, the phase shift in Eq. (2) is altered

ϕRot,i=4keff,iΩxvy,iT2+2keff,iθ1xyi+2keff,iθ3x(yi+2vy,iT)4keff,iΩyvx,iT22keff,iθ1yxi2keff,iθ3y(xi+2vx,iT) 3

where θnα (n = 1, 3, α = x, y) is the tilt angle component of the deflector for the nth Raman pulse and αi and vα,i are the position and velocity components of the atomic cloud for the first Raman pulse. By properly adjusting θ, one can eliminate the decoherence effect caused by the initial position and velocity18, thus increase the contrast of the interference fringe.

Optimized the Raman laser ratio to eliminate the AC-Stark shift

The Raman lasers cause an AC-Stark shift of the interference transitions of the Rb atoms, which results in phase shifts of the interference fringes. By adjusting the offsets and intensity ratios of the Raman lasers, the AC-Stark shift can be eliminated. However, in our experimental setup, the strategy was slightly more complicated. There are two main reasons. First, the dual-species interferometers are operated synchronously, we have to eliminate the AC-Stark shifts for 85Rb and 87Rb simultaneously. Second, the Raman laser sidebands are generated by fiber electro-optical modulators (FEOMs), FEOM produces symmetrical laser sidebands, which makes the calculation of elimination more complex. The differential AC-Stark shifts Δvac,i and the two effective Rabi frequencies Ωeff,i of the Rb isotope can be expressed as

Δvac,i=k,jΩk,j,a,i24Δk,j,a,iΩk,j,b,i24Δk,j,b,i 4
Ωeff,1=jΩ1,j,a,1Ω2,j,b,12Δ1,j,a,1Ω2,j,a,1Ω3,j,b,12Δ2,j,a,1 5a
Ωeff,2=jΩ4,j,a,2Ω5,j,b,22Δ4,j,a,2Ω5,j,a,2Ω6,j,b,22Δ5,j,a,2 5b

where Ωk,j,ab,i and Δk,j,a(b),i are the Rabi frequency and single-photon detuning of the Raman transition, k = 1, 2…6 represents the label of the Raman lasers, the value 1, 2, 3 (4, 5, 6) represent the +1 order sidebands, carrier and 1 order sidebands of the output lasers of the FEOM for 85Rb (87Rb) manipulation, j denotes the label of available excited state for the Rb Raman transition, and a and b represent the 85Rb | F = 2, mF = 0> and |F = 3, mF = 0> (87Rb |F = 1, mF = 0> and |F = 2, mF = 0 > ) ground states.

To determine the optimized intensity ratios and frequency offsets of the Raman lasers, we set the following constraints. First, both the differential AC-Stark shifts of 85Rb and 87Rb are zero, that is Δvac,1=Δvac,2=0, and the effective Rabi frequencies of 85Rb and 87Rb are equal, that is, Ωeff,1=Ωeff,2. We only consider the carrier and ±1 order sidebands for both 85Rb and 87Rb Raman lasers. Then, there are five variables that we can optimize: the two frequency offsets of the two carriers, the two first-order sideband-to-carrier intensity ratios of the 85Rb and 87Rb Raman lasers, and the intensity ratio of the 85Rb Raman laser carrier to the 87Rb Raman laser carrier. The number of variables is greater than the number of equations. Therefore, the optimized variables are not unique. We provide some other constraints for the variables: the single-photon detuning is as large as possible to avoid spontaneous emission, the first-order sideband-to-carrier intensity ratio is not too large to avoid high-order sidebands. We found a following set of optimized parameters. The frequency offset of the 85Rb Raman laser carrier is 986 MHz blue detuned to the 85Rb |F = 3〉→|F′ = 4〉 transition, and the 87Rb Raman laser carrier is 404 MHz blue detuned to the 87Rb |F = 2〉→|F′ = 3〉 transition, and the intensity ratio of the 85Rb Raman laser +1 order sideband and its carrier, the 87Rb Raman laser +1 order sideband and its carrier is 1:1.34:1.69:0.63.

The space cold atom interferometer payload contains three systems: physical, optical, and electronic systems. The three systems were assembled into a 460 mm × 330 mm × 260 mm cabinet, as shown in Fig. 3.

Fig. 3. The space cold atom interferometer payload.

Fig. 3

a Schematic diagram of the scientific payload. b Picture of the scientific payload.

Design of the physical system

The physical system is the place where laser cooling and atom interference occur. It contains a vacuum chamber, its accessories, the supporting structures, the optical components, and a magnetic shield, as shown in Fig. 4.

Fig. 4.

Fig. 4

Cross section view of the physical system.

The vacuum chamber is made of titanium alloy and is maintained by a 2 l ion pump and a getter pump with a level of 108 Pa. The chamber has two regions. The 2D-MOT region is used to generate a high-flux cold atom beam. It has a rubidium source with a heating unit to control the amount of released rubidium. 2D-MOT has a 2D+-MOT configuration. A circularly polarized laser beam in the y-direction passes through the chamber and is reflected by a reflecting mirror to form the push beam of the 2D+-MOT. The reflecting mirror is mounted inside the chamber and has a hole with a diameter of 2 mm. A λ/4 wave plate with a 2 mm hole is attached in front of the mirror. The pushing beam, together with two pairs of laser beams perpendicular to it, form the cooling lasers of the 2D+-MOT, and a pair of anti-Helmholtz coils is used to provide the magnetic field gradient for the 2D+-MOT. The cooled cold atom beam reaches the 3D-MOT region through the hole of the reflecting mirror and a channel that connect the two regions.

In the 3D-MOT region, one laser beam is reflected by a series of wave plates and reflecting mirrors to form three pairs of cooling laser beams. These beams are in the x direction and in the y-z plane. A pair of anti-Helmholtz coils is used to provide a magnetic field gradient for the 3D-MOT. The cooled dual-species Rb atoms are localized at the center of the 3D-MOT chamber. Another laser beam is reflected by the PBS and propagates in the z-direction, which acts as the Raman laser. The laser beam passes through the cold atoms and is reflected by a reflecting mirror mounted on a piezoelectric deflector. A λ/4 wave plate is attached to the reflecting mirror. The fluorescence of cold atoms in the z-direction passes through the PBS and a four-lens imaging system and is imaged by a SCMOS camera. Three photodetectors were installed to detect the power of the 2D, 3D, and Raman lasers.

Three layers of permalloy shells are mounted outside the chamber to shield the external magnetic field. A flux-gate magnetometer is installed inside the magnetic shielding shells to detect residual magnetic fields. Several electronic components are also mounted outside the shells, including the driver for the ion pump, the driver for the piezoelectric deflector, the photon current amplifying circuit, and an IMU module.

The physical system has a size of 300 mm×200 mm×232 mm and a weight of 16 kg. The laser for the physical system is transmitted from the optical system through three single-mode polarization-maintaining fibers.

Design of the optical system

To minimize the volume and increase the thermostability of the optical system, we use a fused quartz glass plate as the baseboard of the optical system. Miniaturized optical components are installed on both sides of the board.

The principle of the optical system is shown in Fig. 5. Two DFB laser diodes (LDs) are used to generate lasers for 85Rb and 87Rb manipulation, labeled as LD1 and LD2, respectively. The output laser of LD1 is split in two ways and then coupled to two single-mode polarization-maintaining (SMPM) fibers, labeled as F1 and F2. F1 is connected to FEOM1, and then sent to a saturation absorption module (SAM), labeled as SAM1. SAM1 uses the Rb isotope 87 vapor cell. And the 1 order sideband of FEOM1 is lock to 87Rb |F = 2 > →|F′ = co(2, 3)> transition. By varying the frequency of microwave that drives FEOM1, we can change the carrier frequency of LD1 from resonance to 85Rb |F = 3 > →|F′ = 4> transition to blue-detuning to this transition for several hundred MHz. F2 is connected to FEOM2, which is driven by microwaves ranging from 2.7 to 3.6 GHz, and the carrier and sidebands of the FEOM2 output laser act as 85Rb cooling, Raman, and detection lasers. The output laser of LD2 has an optical path similar to that of LD1. The difference is that SAM2 employs a 85Rb vapor cell, the +1 order sideband of FEOM3 is locked to the 85Rb |F = 3 > →|F′ = co(3, 4)> transition, and the driven frequency of FEOM4 is ranging from 5.0 to 6.9 GHz.

Fig. 5.

Fig. 5

Schematic diagram of the optical system.

The outputs of FEOM2 and FEOM4 are combined and injected into a tapered amplifier (TA) to amplify the output power. A few fractions of the TA output laser power are split and coupled to a Fabry–Pérot (FP) cavity. The cavity is used to monitor the powers of the carriers and sidebands of the two amplified lasers. Most of the TA output laser power is diffracted by an acousto-optic modulator (AOM) and split into three paths. In each path, a mechanical shutter controls the opening or closing of the output laser with a high extinction ratio. The lasers of the three paths are then coupled to three SMPM fibers and sent to the physical system. They act as 2D, 3D, and Raman lasers. The maximum total output power is about 100 mW. Several photodetectors are installed in the optical system to monitor the laser powers of the nodes of the optical path. The optical system has a size of 270mm×110mm×250mm and a weight of 5.2 kg.

Design of the electronic system

The electronic system is used to drive and control the payload. It is divided into three units: the power supply, main control, and functional circuit units. The payload operates in remote control mode. All operations can be only realized by commands sent from the ground. The MSLC receives these commands and transfers them to the scientific payload.

The power supply unit is used to convert the 28 V input voltage to ±5, 12, ±15, 24, and 28 V output voltages, which are used to provide the power supplies for the entire electronic system. The power supply unit also has a power switch function; it can receive commands from the main control unit to control the switches of the output power supply. The main control unit has several functions, including receiving and processing the transferred commands, controlling the switch states of the power supplies, setting the parameters and switch states of the functional circuits, controlling scientific processes such as laser cooling and atom interference by generating AO and DO time sequences, acquiring and processing the generated data, and transferring them to the ground. The functional circuit unit is a collection of a series of individual circuits, including the constant-current circuit, the temperature control circuit, and the microwave generation circuit. The constant-current circuit is used to drive the LDs, TA, shutters, and coils in the physical system. The temperature control circuit is used to control the temperature of the LDs, TA, Rb vapor cells, and the rubidium source of the vacuum chamber. The microwave generation circuit is used to generate microwaves to drive the four FEOMs and the AOM. The electronic system had a stacked structure with a size of 247mm×140mm×250mm and a weight of 6.5 kg.

Reporting summary

Further information on research design is available in the Nature Research Reporting Summary linked to this article.

Results and discussion

Experiment process in space

The major scientific goal of our project is to test WEP with high precision. To achieve this goal, the experimental process was divided into the laser cooling, atom interference, and fluorescence detection stages, as shown in Fig. 6.

Fig. 6.

Fig. 6

Schematic diagram of the experiment process in space.

The laser cooling stage can be further divided into 2D-MOT, 3D-MOT, and PGC stages. In the 2D-MOT stage, the shutters for the 2D and 3D lasers are open and the shutter for the Raman laser is closed, the carrier frequency of LD1 (LD2) is set to be −16 MHz detuning to the 85Rb |F = 3〉→|F′ = 4〉 transition (87Rb |F = 2〉→|F′ = 3〉 transition), and the +1 sidebands of LD1 (LD2) are in resonance with the 85Rb |F = 2〉→|F′ = 3〉 transition (87Rb |F = 1〉→|F′ = 2〉 transition). The anti-Helmholtz coils for the 2D+ and 3D-MOT were turned on. In this state, a slow cold atom beam is generated in the 2D-MOT region and transferred to the 3D-MOT region, in which 3D-MOT accumulate atoms for several seconds. In the 3D-MOT stage, the shutter for the 2D laser was closed, and the coils for the 2D+-MOT were turned off. The carrier frequency of LD1 (LD2) was set to be −60 MHz detuning to the 85Rb |F = 3〉→|F′ = 4〉 transition (87Rb |F = 2〉→|F′ = 3〉 transition), whereas the +1 sidebands of LD1 (LD2) were still in resonance with the 85Rb | F = 2〉→|F′ = 3〉 transition (87Rb |F = 1〉→|F′ = 2〉 transition). This stage lasts for approximately 100 ms, because the influence of the cold atom beam and the magnetic field of the 2D-MOT are absent, the position of the 3D-MOT can be localized to the center of the 3D-MOT chamber. In the PGC stage, the coils for the 3D-MOT were turned off, the intensity of the cooling laser was turned to zero in approximately 4 ms, and the temperature was decreased to several μK.

In the atom interference stage, the shutter for the 3D laser was closed, and the shutter for the Raman laser was open. The carrier frequency of LD1 (LD2) was set to be 986 MHz (404 MHz) detuning to the 85Rb |F = 3〉→|F′ = 4〉 transition (87Rb |F = 2〉→|F′ = 3〉 transition), and the frequency of the microwave for FEOM2 (FEOM4) was tuned to 3.035 GHz (6.835 GHz). The Raman laser was turned on for tens of μs for the first Raman pulse, and the 85Rb (87Rb) atoms are transferred from the |F = 3, mF = 0〉 (|F = 2, mF = 0〉) state to the |F = 2, mF = 0> (|F = 1, mF = 0〉) state. Then, the carrier frequency of LD1 (LD2) was set to be in resonance with the 85Rb |F = 3〉→|F′ = 4〉 transition (87Rb |F = 2〉→|F′ = 3〉transition), and the sidebands for LD1(LD2) were turned off by shutting down the corresponding microwave. The blow-away laser was turned on for tens of μs, and this process removed the remaining 85Rb (87Rb) atoms in the |F = 3〉 (|F = 2〉) state. Subsequently, the second Raman pulse, the second blow-away pulse, and the third Raman pulse were turned on in sequence. After the interference sequence, the 85Rb (87Rb) atoms were in superposition states of |F = 2, mF = 0〉 and |F = 3, mF = 0〉 (|F = 1, mF = 0〉 and |F = 2, mF = 0〉). In the interference stage, the angle of the deflector at the moments of the three Raman pulses was turned according to the rotation rate measured by the IMU to compensate for the residual rotation. The maximum interval between the Raman pulses was approximately 1 s, which is limited by the size of the vacuum chamber.

In the fluorescence detection stage, the shutter for the 3D laser was open, the shutter for the Raman laser was closed, the carrier frequency of LD1 (LD2) was set to be in resonance with the 85Rb |F = 3〉→|F′ = 4〉 transition (87Rb |F = 2〉→|F′ = 3〉transition), and the sidebands for LD1 (LD2) were turned off by shutting down the corresponding microwave. We turned on the detection pulses for 85Rb and 87Rb in sequence, and the fluorescence of the 85Rb (87Rb) atoms in the |F = 3, mF = 0〉 (|F = 2, mF = 0〉) were imaged by the camera. The minimum time interval between the two detection pulses was approximately 20 ms, which was limited by the frames per second (FPS) of the camera. From the image of the atomic cloud, we can obtain the phase shear interference fringe for the atomic cloud, where the phase of the fringe represents the acceleration felt by the atomic cloud. By comparing the accelerations of the two atomic clouds, we can test the WEP.

The breaking of the WEP can be expressed by the Eötvös coefficient η

η=g1g2(g1+g2)/2=(g1as)(g2as)(g1+g2)/2=a1a2(g1+g2)/2=Δag 6

where gi is the gravitational acceleration for the Rb isotope. For experiment in space, the atomic cloud feels a centrifugal force as in Newton’s laws. The measured atom acceleration is ai in the frame of the aircraft; thus, η can be measured by the differential acceleration Δa and the gravitational acceleration g of the earth, as illustrated by Eq. (6). The orbital altitude of the CSS is approximately 400 km, and the corresponding gravitational acceleration is g=8.7 m s−2. The phase of the atom interference fringe induced by the acceleration is ϕi=2keff,iaiT2. Then η can be expressed as

η=Δϕ2keff,1gT2Δk2keff,1a2g 7

where Δϕ=ϕ1ϕ2 is the differential phase and Δk=2(keff,1keff,2) is the differential wave vector.

For the first term in Eq. (7), the parameters keff,1, T can be set by the experiment, and g can be calculated by the orbit of CSS. The normalized precision of the setting value (keff,i to 108, T to 106, and g to 103) are much higher than the aimed normalized precision (approximately 1 if WEP does not break) of η to be measured. Thus, the values of keff,i, T and g can be safely used in this term without loss of measurement precision. The second term has a suppression ratio term Δk/2keff,1, which was 5×107 in our experiment, and a relative acceleration term a2/g. If one wants the value of this term to be less than 1011, it results in an upper limit for the residual acceleration a2 of 2×105 g, and this can be guaranteed by the MSB. Therefore, the measured precision of η is primarily limited by the differential phase Δϕ.

Many factors influence the value of Δϕ, and we list the most important terms as below, and we set T=1s for the following calculation.

Quantum projection noise

Quantum projection noise originates from the state collapse process of a superposition state. For a dual-species atom interferometer, the differential phase noise caused by the quantum projection effect can be expressed as

σΔϕ=i=1,21NiCi2 8

where Ni is the atomic number participating in the interference process, Ci is the contrast of the interference fringe. Considering the magnetic sublevels and consumption of the atom number caused by the velocity selection, the atoms participate in the interference are N1=3.7×104 and N2=5.2×104. Assuming that Ci=0.2, the differential phase noise caused by the quantum projection effect in a single shot is 34 mrad.

Detection noise

The image of the interference fringe was captured by the SCMOS camera, and there was detection noise in the imaging process. This noise has three origins: the shot noise, which is a quantum noise, and is relative to the photoelectron number converted by the camera. The readout noise is caused by the noise floor of the camera’s readout circuit. The dark noise is the thermal photoelectron noise of the SCMOS. The effective differential phase noise caused by the detection noise can be expressed as

σΔϕ=i=1,21Ci2Ncounts,i+mδread2Ci2Ncounts,i2+mtexpδdark2Ci2Ncounts,i2 9

where Ncounts,i is the total number of photoelectrons recorded by the camera, m is the number of pixels, δread and δdark are the readout noise and dark noise of the camera, which are 2.2 e pixel−1 and 2.3 e pixel−1 s−1/2 for the used camera, and texp is the exposure time. The total number of photoelectrons was calculated using the following equation,

Ncounts,i=NiβγtdetΓiI0,i/Is,i21+4Δi/Γi2+I0,i/Is,i 10

where β is the quantum efficiency of the camera, γ is the detection ratio of atomic fluorescence, tdet is the duration of the detection laser, Γi is the decay rate for the Rb D2 transition, I0,i is the intensity of the detection laser, Is,i is the saturation intensity of the Rb D2 transition. For the typical parameters that we used, the differential phase noise caused by the detection noise is about 22 mrad in one shot.

Effect of the rotation and gravity gradient

The rotation of the payload and gravity gradient of the Earth and CSS induces a phase shift to the interference fringe. The rotation-induced phase shift is given by Eq. (3), and the gravity gradient-induced phase is

ϕgg,i=2keff,iTzzziT2+2keff,iTzzvz,iT3 11

where Tzz is the (z, z) component of the gravity gradient tensor, and zi and vz,i are the position and velocity components of the atoms for the first Raman pulse. According to Eqs. (3) and (11), offsets for the initial position and velocity of the two atomic clouds will induce a differential phase shift. For our payload design, the rotation measurement uncertainty of the IMU is about 1 μrad s−1 and the angle control uncertainty of the deflector is about 5 μrad, the gravity gradient at the altitude of the CSS has value of about Tzz= 2500 E. The difference of the initial position and velocity of the two atomic clouds were approximately 200 μm and 100 μm s−1 according to the test results on ground. Then, the uncertainty differential phases caused by the rotation and gravity gradient were calculated to be 102 and 18 mrad, respectively.

Effect of the magnetic field

In the process of atomic interference, a uniform magnetic field is generated in the z-direction to act as the quantization magnetic field. For the double-diffraction Raman interference transition, the differential phase shift caused by the second-order Zeeman effect of the states is

Δϕmag=4πkeff,1α1m1keff,2α2m2B0γmT2 12

where is Planck’s constant, αi is the clock transition Zeeman shift coefficient, mi is the mass of the Rb atom, B0 is the intensity of the magnetic field intensity, and γm is the magnetic field gradient. To reduce this phase shift, three layers of magnetic shielding shells were used to attenuate the external stray magnetic field, and the parameters of the interference coils were carefully designed to reduce the magnetic gradient. For our experiment, the magnetic field can be adjusted to 0.1 G and the measured magnetic gradient is less than 3 mG m−1, then the differential phase caused by the second Zeeman effect was 33 mrad.

Effect of the AC-Stark shift

We derived an optimized Raman laser ratio to eliminate the differential AC-Stark shift in method section. However, the AC-Stark shift for a single state still exists. The interference loop of the double-diffraction Raman interference employs only one single internal state, and a constant AC-Stark shift of this state does not cause a fringe phase shift. The phase shift can be induced only by the AC-Stark shift difference δvac,i of the two branches of the interference loop at the π pulse. The induced phase shift can be calculated as follows,

ϕac,i=4δvac,iτ 13

where τ is the duration of the π pulse. δvac,i can be induced by the intensity gradient of the Raman laser in the z-direction.

For the parameters of our experiment, if we set the duration of the π pulse is τ=160μs, then the AC-Stark shift is calculated to be 387.4 Hz (2263.1 Hz) for the 85Rb atom |F = 2, mF = 0〉 state (87Rb atom |F = 1, mF = 0〉 state). The diameter of the Raman laser is designed to be 1.7 cm, for a separation of the atomic cloud wave packet of 2 cm, the relative difference intensity is that the atom felt at the two branches is calculated to be about 8×105. Then the differential phase shift induced by the AC-Stark shift is about 1 μrad.

Effect of the wave front aberration

The aberration of the reflecting mirror of the Raman laser will causes a phase distortion of the Raman laser in the x-y plane. This phase distortion will be coupled with the atomic cloud sizes at the three Raman pulses and induces a phase shift for the interference fringe42. For experiment of our case, the phase shifts are mostly in common. This is because that we use the velocity selection method, so the selected atomic clouds have a same expansion rate, and the difference of effective Raman vectors of the Rb atoms is small, this will induce similar phase shifts for the two AIs, as illustrated in the paper43. For a mirror with a diameter of 22 mm, and has a peak aberration of λ/5, the differential phase is calculated to be about 2.3 μrad.

The estimated uncertainties of the WEP test experiment for 100 shots are listed in Table 1. The estimated uncertainties contain both the random uncertainties and the systematic uncertainties. The mainly error source comes from the rotation, the gravity gradient and the magnetic field. The expected test precision is in the order of 1010.

Table 1.

Estimated test uncertainties of the WEP test experiment.

Error source Estimated uncertainty
Quantum projection noise 1.2×1011
Detection noise 8.0×1012
Rotation 3.6×1010
Gravity gradient 6.4×1011
Magnetic field 1.2×1010
AC-Stark shift 3.4×1015
Wavefront aberration 1.0×1014
Total 4.0×1010

It is still possible to improve the test precision during the whole lifetime of the payload. The in orbit scientific experiment could last for more than 1 year, and we could obtain more than 104 scientific experiment pictures. The expected test precision could be improved for several aspects. The quantum projection noise and detection noise could be averaged to a lower level due to increased amount of data. The magnetic field effect could be reduced by reversing the atomic states44. The rotation effect could be reduced by precisionly measuring the differential position and velocity of two atomic clouds. The gravity gradient effect could be reduced by applying the modulation-demodulation method to separate the WEP signal and the gravity gradient signal45. The WEP test precision could be possibly improved to the order of 1011 ~ 1012.

Ground test for the scientific payload

We carried out tests to verify the functions and performances of the scientific payload. The tests covered the power supply, communication, functional circuits, optical system, and physical system. We also conducted an environmental test to verify that it can adapt to the environment for rocket launching and in-orbit operation. The payload passed the sinusoidal vibration (5.6 g in peak) and random vibration tests (4.28 g RMS) with the protection of a shockproof package and passed the thermal cycling test from 15 to 32 °C. Due to the limited execution time of the project, we do not have enough time to carry out the ground-based microgravity experiments such as the drop tower or the parabolic flight experiment. However, we carried out a series of laboratory-based experiments, including the atom cooling and atom interference experiments.

For the experiment in space, the cold atomic clouds are at rest in the center of the 3D-MOT chamber after release. However, for the ground-based experiments, the released cold atomic cloud will free fall under the gravity of the Earth. If we set the z-axis along the direction of gravity, then the limited detection range allowed only tens of milliseconds of free fall time. This caused problem for both the time-of-flight (TOF) image and the atom interference produced. To extend the allowed detection time, we rotated our payload and set the x-axis along the direction of gravity. Under these conditions, the free-fall atom can be detected by the laser in the x-direction and is in the object plane of the imaging system. The maximum detectable time was limited by the image range of the camera and was approximately 45 ms in our experiment.

The laser cooling experiment follows the produce introduced above. The image of the cold 85Rb atomic cloud in the 3D-MOT and TOF images of the atomic clouds after the PGC process are shown in Fig. 7. The atom number was calculated to be more than 2×108 and the calculated atomic temperature was about 4 μK in one dimension.

Fig. 7. TOF fluorescence images of the 85Rb atomic cloud with different falling time.

Fig. 7

Insert image is 3D-MOT fluorescence image.

After the PGC process, the shutter for the 3D laser was closed, and the shutter for the Raman laser was open. The carrier frequency of LD1 was set to be resonant with the 85Rb |F = 3〉→|F′ = 3〉 transition, the sidebands for LD1 were turned off, the laser was turned on for tens of microseconds, and the 85Rb atoms were optically pumped from the |F = 3〉 state to the |F = 2〉 state. Then, the carrier frequency of LD1 was set to be 800 MHz blue detuning to the 85Rb |F = 3〉→|F′ = 4〉 transition, and the frequency of the microwave for FEOM2 was tuned to 3.035 GHz. The Raman laser was turned on for 80 μs, 160 μs and 80 μs for the first, second and third Raman pulses, and the interference time interval was set to 5 ms. After the interference sequence, the atoms in the |F = 3> state were imaged. To realize the phase shear of an atomic cloud, the angle of the deflector was linearly scanned during the interference to induce a phase shift.

We used principal component analysis (PCA) process to obtain the interference fringe from the atomic interference images. We used 38 images for the process and took the 4th order of the processed images. The curve in Fig. 8 is the average of the processed images in the x-direction. To obtain the interference fringe, we tuned the Raman laser to be in resonance, and rotated the deflector at a proper rotation rate. The obtained curve is shown as the blue solid line. We can see a clear fringe. We also carried out comparative experiments. First, we kept the deflector with the same rotation rate, and tuned the Raman laser to be detuned by +100 kHz. The obtained curve is shown as the blue dashed line, the fringe disappeared. Then we stop the deflector rotation, and tuned the Raman laser to be in resonance again. The obtained curve is shown as red solid line. Again, the fringe disappeared.

Fig. 8. Double-diffraction Raman interference fringes of the 85Rb atoms.

Fig. 8

The PCA process is applied and 38 images are used for each curve. The curves are the averages of the processed images of the 4th order in the x-direction. The blue solid line and the insert image represents the case when the Raman laser is in resonance and the deflector rotates at a proper rate. The blue dashed line represents the case when the Raman laser is out of resonance and the deflector rotates at a same rate. The red solid line represents the case when the Raman laser is in resonance and the deflector is not rotated.

The contrast of the obtained interference fringe is very low. This is mainly caused by the following reasons. First, during the interference process, the laser intensities of the three Raman pulses were different because the atoms fell in the x-direction, and the Raman laser was propagated in the z-direction. Second, after the interference process, we detected atoms in the state |F = 3 > . However, during the interference process, most atoms were populated in the |F = 2> magnetic sublevels. The single-photon transition effect of the Raman laser pumped a proportion of these atoms to the |F = 3> state, and this contributed to the background of the interference fringe. Third, the interference time was too short to set a stable angular sequence for the deflector. We could only scan the angle at a certain rate, therefore, we could hardly optimize the three angles of the deflector for the three Raman pulses, as described in method section, which induced a decoherence effect caused by the initial size of the atomic cloud. However, all of these factors can be relieved for the experiment in space.

The MSLC in the CSS provides a good environment for experiments that require a high-level of microgravity. In this paper, we discuss the design and realization of a dual-species atom interferometer that will work in the MSLC in space, aiming at testing the WEP with high precision. We introduced the scheme of the design of our atom interferometer, which is mainly constructed by the method of 3D velocity selection, the method of double-diffraction Raman interference scheme associated with the phase shear fluorescence detection, and the method of rotation compensation by a piezoelectric deflector. We optimized the Raman laser ratio for eliminating the AC-Stark shift for our experiment. Then we designed experimental process for space experiment, the compact scientific payload and its sub-systems. We carefully analyze the test precision of WEP of our payload by the parameters of the pre-researches, the expected test precision is in the order of 1010. We also present the laser cooling and interference experiment results on the ground.

The MSLC also restricts the size and power consumption of the scientific payload that it supports. The payload we design is extremely compact and have a size of only 460mm×330mm×260mm. This limits the expected test precision for several aspects. The interference time is limited by the size of the vacuum chamber. The interference produce can only begin from atoms that created by the dual-species 3D-MOT, rather than ultra cold atoms that trapped by the magnetic trap or the optical dipole trap. The rotation and compensation angle of payload can not to be controlled to an extremely high level due to the current microgravity environment and the performance to the compact piezoelectric deflector. The gravity gradient compensation strategy cannot be utilized due to the limited frequency detuning range of the optical system. It should be noted that for atom interferometer works on a platform with better microgravity performance and relaxed design restrictions, much higher measurement accuracy can be obtained.

We hope that the design and implementation of the payload can provide certain benefits for future space-based atom interferometer designs.

Supplementary information

Reporting Summary (67.4KB, pdf)

Acknowledgements

We would like to thank the support from Technology and Engineering Center for Space Utilization, CAS, especially Hongen Zhong, Zongfeng Li, and many others for their constructive discussions and technical supports. We would like to thank professor Yuri Ovchinnikov for his kind guidance for the design of the 2D-MOT. This work was supported by the Second Batch of Scientific Experiment Project of the Space Engineering Application System of the China Space Station. We acknowledge support from the Technological Innovation 2030 "Quantum Communication and Quantum Computer" Major Project (2021ZD0300603, 2021ZD0300604), the Hubei Provincial Science and Technology Major Project (ZDZX2022000001), the China Postdoctoral Science Foundation (2020M672453) and National Natural Science Foundation of China (91536221, 12204493).

Author contributions

X.C. led the planning, design, development, and testing of the project. J.Q.Z., X.W. Z., Y.W and G.G.G were responsible for the development of physical system. J.F., D.F.Z, and X.L. were responsible for the development of optical system. Q.F.C., H.Y.S, W.H.P, L. Q., Z.Y.X., Z.D.C. and W.Z.W. were responsible for the development of electronic system. K.L., J.T.L., Z.Y.C., G.Z., Y.Z. were responsible for software development. Y.B.W., M.H, J.T.L., L.Z, C.H., R.D.X. and J.J.J. were responsible for the daily experimental operation, payload testing and data acquisition and analysis. M.S.Z. and J.W. proposed the experiment and coordinated with the principal members as the project scientists. M.H. and X.C. prepared the manuscript. All authors have read and approved the final manuscript.

Data availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Code availability

The code that support the findings of this study are available from the corresponding author upon reasonable request.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Xi Chen, Email: chenxi@apm.ac.cn.

Jin Wang, Email: wangjin@apm.ac.cn.

Mingsheng Zhan, Email: mszhan@apm.ac.cn.

Supplementary information

The online version contains supplementary material available at 10.1038/s41526-023-00306-y.

References

  • 1.Damour T, Piazza F, Veneziano G. Violations of the equivalence principle in a dilaton-runaway scenario. Phys. Rev. D. 2002;66:046007. doi: 10.1103/PhysRevD.66.046007. [DOI] [PubMed] [Google Scholar]
  • 2.Dvali G, Zaldarriaga M. Changing alpha with time: implications for fifth-force-type experiments and quintessence. Phys. Rev. Lett. 2002;88:091303. doi: 10.1103/PhysRevLett.88.091303. [DOI] [PubMed] [Google Scholar]
  • 3.Hohensee MA, Müller H, Wiringa RB. Equivalence principle and bound kinetic energy. Phys. Rev. Lett. 2013;111:151102. doi: 10.1103/PhysRevLett.111.151102. [DOI] [PubMed] [Google Scholar]
  • 4.Potter HH. Some experiments on the proportionality of mass and weight. Proc. R. Soc. Lond. 1923;104:588–610. [Google Scholar]
  • 5.Williams JG, Turyshev SG, Boggs DH. Progress in lunar laser ranging tests of relativistic gravity. Phys. Rev. Lett. 2004;93:261101. doi: 10.1103/PhysRevLett.93.261101. [DOI] [PubMed] [Google Scholar]
  • 6.Wagner TA, Schlamminger S, Gundlach JH, Adelberger EG. Torsion-balance tests of the weak equivalence principle. Class. Quantum Grav. 2012;29:184002. doi: 10.1088/0264-9381/29/18/184002. [DOI] [Google Scholar]
  • 7.Savchenko V, et al. INTEGRAL Detection of the first prompt gamma-ray signal coincident with the gravitational-wave event GW170817. Astrophys. J. Lett. 2017;848:L15. doi: 10.3847/2041-8213/aa8f94. [DOI] [Google Scholar]
  • 8.Wei JJ, et al. Multimessenger tests of the weak equivalence principle from GW170817 and its electromagnetic counterparts. J. Cosmol. Astropart. Phys. 2017;2017:035. doi: 10.1088/1475-7516/2017/11/035. [DOI] [Google Scholar]
  • 9.Fray S, Diez CA, Hansch TW, Weitz M. Atomic interferometer with amplitude gratings of light and its applications to atom based tests of the equivalence principle. Phys. Rev. Lett. 2004;93:240404. doi: 10.1103/PhysRevLett.93.240404. [DOI] [PubMed] [Google Scholar]
  • 10.Bonnin A, Zahzam N, Bidel Y, Bresson A. Simultaneous dual-species matter-wave accelerometer. Phys. Rev. A. 2013;88:043615. doi: 10.1103/PhysRevA.88.043615. [DOI] [Google Scholar]
  • 11.Schlippert D, et al. Quantum test of the universality of free fall. Phys. Rev. Lett. 2014;112:203002. doi: 10.1103/PhysRevLett.112.203002. [DOI] [Google Scholar]
  • 12.Tarallo MG, et al. Test of Einstein equivalence principle for 0-spin and half-integer-spin atoms: search for spin-gravity coupling effects. Phys. Rev. Lett. 2014;113:023005. doi: 10.1103/PhysRevLett.113.023005. [DOI] [PubMed] [Google Scholar]
  • 13.Bonnin A, Zahzam N, Bidel Y, Bresson A. Characterization of a simultaneous dual-species atom interferometer for a quantum test of the weak equivalence principle. Phys. Rev. A. 2015;92:023626. doi: 10.1103/PhysRevA.92.023626. [DOI] [Google Scholar]
  • 14.Zhou L, et al. Phys. Rev. Lett. 2015;115:013004. doi: 10.1103/PhysRevLett.115.013004. [DOI] [PubMed] [Google Scholar]
  • 15.Albers H, et al. Quantum test of the universality of free fall using rubidium and potassium. Eur. Phys. J. D. 2020;74:145. doi: 10.1140/epjd/e2020-10132-6. [DOI] [Google Scholar]
  • 16.Zhou L, et al. Phys. Rev. A. 2021;104:022822. doi: 10.1103/PhysRevA.104.022822. [DOI] [Google Scholar]
  • 17.Zhou L, et al. Toward a high-precision mass–energy test of the equivalence principle with atom interferometers. Front. Phys. 2022;10:1039119. doi: 10.3389/fphy.2022.1039119. [DOI] [Google Scholar]
  • 18.Asenbaum P, et al. Phys. Rev. Lett. 2020;125:191101. doi: 10.1103/PhysRevLett.125.191101. [DOI] [PubMed] [Google Scholar]
  • 19.Duan XC, et al. Test of the universality of free fall with atoms in different spin orientations. Phys. Rev. Lett. 2016;117:023001. doi: 10.1103/PhysRevLett.117.023001. [DOI] [PubMed] [Google Scholar]
  • 20.Zhang K, et al. Testing the universality of free fall by comparing the atoms in different hyperfine states with bragg diffraction. Chin. Phys. Lett. 2020;37:043701. doi: 10.1088/0256-307X/37/4/043701. [DOI] [Google Scholar]
  • 21.Rosi G, et al. Quantum test of the equivalence principle for atoms in coherent superposition of internal energy states. Nat. Commun. 2017;8:15529. doi: 10.1038/ncomms15529. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Touboul P, et al. MICROSCOPE Mission: Final Results of the Test of the Equivalence Principle. Phys. Rev. Lett. 2022;129:121102. doi: 10.1103/PhysRevLett.129.121102. [DOI] [PubMed] [Google Scholar]
  • 23.Rudolph J, et al. Degenerate quantum gases in microgravity. Microgravity Sci. Technol. 2010;23:287–292. doi: 10.1007/s12217-010-9247-0. [DOI] [Google Scholar]
  • 24.Becker D, et al. Space-borne Bose-Einstein condensation for precision interferometry. Nature. 2018;562:391–395. doi: 10.1038/s41586-018-0605-1. [DOI] [PubMed] [Google Scholar]
  • 25.Lachmann MD, et al. Ultracold atom interferometry in space. Nat. Commun. 2021;12:1317. doi: 10.1038/s41467-021-21628-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Nyman RA, et al. I.C.E.: a transportable atomic inertial sensor for test in microgravity. Appl. Phys. B. 2006;84:673–681. doi: 10.1007/s00340-006-2395-7. [DOI] [Google Scholar]
  • 27.Barrett B, et al. Dual matter-wave inertial sensors in weightlessness. Nat. Commun. 2016;7:13786. doi: 10.1038/ncomms13786. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Ahlers, H. et al. STE-QUEST: space time explorer and quantum equivalence principle space test. Preprint at https://arxiv.org/abs/2211.15412v3 (2022).
  • 29.Könemann T, et al. A freely falling magneto-optical trap drop tower experiment. Appl. Phys. B. 2007;89:431–438. doi: 10.1007/s00340-007-2863-8. [DOI] [Google Scholar]
  • 30.Van Zoest T, et al. Bose-Einstein Condensation in microgravity. Science. 2010;328:1540–1543. doi: 10.1126/science.1189164. [DOI] [PubMed] [Google Scholar]
  • 31.Müntinga H, et al. Interferometry with Bose-Einstein condensates in microgravity. Phys. Rev. Lett. 2013;110:093602. doi: 10.1103/PhysRevLett.110.093602. [DOI] [PubMed] [Google Scholar]
  • 32.Tino GM, et al. Precision gravity tests with atom interferometry in space. Nucl. Phys. B. 2013;243-244:203–217. doi: 10.1016/j.nuclphysbps.2013.09.023. [DOI] [Google Scholar]
  • 33.Williams J, Chiow SW, Yu N, Müller H. Quantum test of the equivalence principle and space-time aboard the International Space Station. N. J. Phys. 2016;18:025018. doi: 10.1088/1367-2630/18/2/025018. [DOI] [Google Scholar]
  • 34.Elliott ER, et al. NASA’s Cold Atom Lab (CAL): system development and ground test status. NPJ Microgravity. 2018;4:16. doi: 10.1038/s41526-018-0049-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Aveline DC, et al. Observation of Bose-Einstein condensates in an Earth-orbiting research lab. Nature. 2020;582:193–197. doi: 10.1038/s41586-020-2346-1. [DOI] [PubMed] [Google Scholar]
  • 36.Frye K, et al. The Bose-Einstein Condensate and Cold Atom Laboratory. EPJ Quantum Technol. 2021;8:1. doi: 10.1140/epjqt/s40507-020-00090-8. [DOI] [Google Scholar]
  • 37.Sorrentino F, et al. A compact atom interferometer for future space missions. Microgravity Sci. Technol. 2010;22:551–561. doi: 10.1007/s12217-010-9240-7. [DOI] [Google Scholar]
  • 38.Tino GM, et al. SAGE: A proposal for a space atomic gravity explorer. Eur. Phys. J. D. 2019;73:228. doi: 10.1140/epjd/e2019-100324-6. [DOI] [Google Scholar]
  • 39.Ovchinnikov YB. Compact magneto-optical sources of slow atoms. Opt. Commun. 2005;249:473–481. doi: 10.1016/j.optcom.2005.01.047. [DOI] [Google Scholar]
  • 40.Lévèque T, et al. Enhancing the area of a Raman atom interferometer using a versatile double-diffraction technique. Phys. Rev. Lett. 2009;103:080405. doi: 10.1103/PhysRevLett.103.080405. [DOI] [PubMed] [Google Scholar]
  • 41.Sugarbaker A, et al. Enhanced atom interferometer readout through the application of phase shear. Phys. Rev. Lett. 2013;111:113002. doi: 10.1103/PhysRevLett.111.113002. [DOI] [PubMed] [Google Scholar]
  • 42.Schkolnik V, et al. The effect of wavefront aberrations in atom interferometry. Appl. Phys. B. 2015;120:311–316. doi: 10.1007/s00340-015-6138-5. [DOI] [Google Scholar]
  • 43.Hu JG, et al. Analysis and suppression of wave-front-aberration phase noise in weak-equivalence-principle tests using dual-species atom interferometers. Phys. Rev. A. 2017;96:023618. doi: 10.1103/PhysRevA.96.023618. [DOI] [Google Scholar]
  • 44.Hu QQ, et al. Mapping the absolute magnetic field and evaluating the quadratic Zeeman-effect-induced systematic error in an atom interferometer gravimeter. Phys. Rev. A. 2017;96:033414. doi: 10.1103/PhysRevA.96.033414. [DOI] [Google Scholar]
  • 45.Chiow S-W, Williams J, Yu N, Müller H. Gravity-gradient suppression in spaceborne atomic tests of the equivalence principle. Phys. Rev. A. 2017;95:021603R. doi: 10.1103/PhysRevA.95.021603. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Reporting Summary (67.4KB, pdf)

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

The code that support the findings of this study are available from the corresponding author upon reasonable request.


Articles from NPJ Microgravity are provided here courtesy of Nature Publishing Group

RESOURCES