Repeated measurements of tibia lead concentrations by in vivo x ray fluorescence in occupational exposure.

R Armstrong 1, D R Chettle 1, M C Scott 1, L J Somervaille 1, M Pendlington 1
PMCID: PMC1039227  PMID: 1733451

Abstract

A group of workers occupationally exposed to lead have had measurements of their tibia lead concentrations made on two occasions separated by five years; on the second occasion calcaneus lead concentrations were also measured. The results serve to confirm the reliability of the measurement technique and to illustrate the improved precision achieved through technical improvements. More importantly, the relation between tibia lead concentration and cumulative blood lead found in this longitudinal study was entirely consistent with that previously reported, which had been based on cross sectional studies. Furthermore, the relation between lead concentrations in the tibia and in calcaneus found here was similar to that previously found in a larger cross sectional survey. It is concluded that this technique of measuring bone lead concentrations non-invasively is likely to be used increasingly as a biological monitor of cumulative exposure to lead.

Full text

PDF
14

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ahlgren L., Lidén K., Mattsson S., Tejning S. X-ray fluorescence analysis of lead in human skeleton in vivo. Scand J Work Environ Health. 1976 Jun;2(2):82–86. doi: 10.5271/sjweh.2815. [DOI] [PubMed] [Google Scholar]
  2. Chettle D. R., Scott M. C., Somervaille L. J. Improvements in the precision of in vivo bone lead measurements. Phys Med Biol. 1989 Sep;34(9):1295–1300. doi: 10.1088/0031-9155/34/9/014. [DOI] [PubMed] [Google Scholar]
  3. Rabinowitz M. B., Wetherill G. W., Kopple J. D. Kinetic analysis of lead metabolism in healthy humans. J Clin Invest. 1976 Aug;58(2):260–270. doi: 10.1172/JCI108467. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Somervaille L. J., Chettle D. R., Scott M. C. In vivo measurement of lead in bone using x-ray fluorescence. Phys Med Biol. 1985 Sep;30(9):929–943. doi: 10.1088/0031-9155/30/9/005. [DOI] [PubMed] [Google Scholar]
  5. Somervaille L. J., Chettle D. R., Scott M. C., Tennant D. R., McKiernan M. J., Skilbeck A., Trethowan W. N. In vivo tibia lead measurements as an index of cumulative exposure in occupationally exposed subjects. Br J Ind Med. 1988 Mar;45(3):174–181. doi: 10.1136/oem.45.3.174. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Somervaille L. J., Nilsson U., Chettle D. R., Tell I., Scott M. C., Schütz A., Mattsson S., Skerfving S. In vivo measurements of bone lead--a comparison of two x-ray fluorescence techniques used at three different bone sites. Phys Med Biol. 1989 Dec;34(12):1833–1845. doi: 10.1088/0031-9155/34/12/007. [DOI] [PubMed] [Google Scholar]

Articles from British Journal of Industrial Medicine are provided here courtesy of BMJ Publishing Group

RESOURCES