. 2023 Aug 1;18(4):905–916. doi: 10.26603/001c.83259

Maximal and Explosive Muscle Strength During Hip Adduction Squeeze and Hip Abduction Press Test Using A Handheld Dynamometer: An Intra- and Inter-tester Reliability Study

Lasse Ishøi 1,, Kristian Thorborg 1, Laura Krohn 1, Lars Louis Andersen 2, Asger Møller Nielsen 1, MIkkel Bek Clausen 1,3
PMCID: PMC10399103  PMID: 37547845

Abstract

Background

Hip adduction and abduction muscle function plays an important role for risk of groin pain in athletes. Maximal isometric strength can be obtained clinically using a handheld dynamometer. However, in very strong athletes this is challenging, as external fixation of the dynamometer is needed for reliable measures. An alternative to unilateral testing, is the long-lever hip adduction squeeze test and a novel bilateral hip abduction press test. While promising intra-tester reliability has been found for maximal strength during the long-lever hip adduction squeeze test, inter-tester reliability may be more challenging during both maximal and explosive strength measurements.

Hypothesis/purpose

The aim of the present study was to assess intra- and inter-tester reliability of maximal, and explosive strength during the long lever hip adduction squeeze test and the long lever hip abduction press test in healthy adults using a hand-held dynamometer.

Study design

Intra- and interrater reliability study.

Methods

Forty-nine healthy subjects were included for intra- (n=20) and inter-tester reliability (n=29). Subjects performed the hip adduction long lever squeeze test and the bilateral hip abduction press test in a randomized order. Maximal isometric strength and early (0-100 ms) and late (0-200 ms) phase rate of force development (explosive muscle strength) was obtained using a hand-held dynamometer. Relative reliability for all tests was assessed using ICC2,1 two-way mixed model with absolute agreement, thereby taking bias between testers into account.

Results

Maximal isometric strength showed good intra- and inter-tester reliability for adduction (ICC: 0.93-0.97) and abduction (ICC: 0.88-0.92). For 0-200 ms rate of force development, both the squeeze and press test showed good intra-tester reliability (ICC: 0.85-0.87), whereas inter-tester reliability was good for hip adduction squeeze (ICC: 0.75) and moderate for hip abduction press (ICC: 0.71). For 0-100 ms rate of force development, the hip abduction press test showed good intra-tester reliability (ICC: 0.78). Remaining tests for intra- and inter-tester reliability showed moderate reliability (ICC: 0.50-0.71).

Conclusion

Assessment of maximal isometric strength in hip adduction squeeze and abduction press test showed good intra- and inter-tester reliability, whereas only 0-200 ms rate of force development demonstrated good intra-tester reliability of both tests. Therefore, rate of force development should preferably be conducted by the same tester, while the long lever squeeze and press test can reliably be used within- and between testers to measure maximal isometric strength.

Level of Evidence

3

Keywords: Groin pain, Hip strength, Reliability, Squeeze test, Rate of force development

INTRODUCTION

Groin pain is common in sport affecting up to 50 % of football and ice hockey players during a season .1–3 Low hip adduction strength increases the risk of adductor-related injuries in male football players,4,5 whereas low eccentric hip adduction strength relative to abduction strength is associated with adductor muscle strains in ice hockey players.6 In addition, a decrease in hip adduction strength precedes groin pain,7 and is also observed in football players with prior season longstanding groin pain >6 weeks.8 Therefore, researchers have proposed evaluation of hip adduction and abduction strength, including the adduction/abduction ratio, as a clinical screening tool to detect early groin pain, aid secondary prevention strategies,9 and guide readiness to play following groin injuries.10–12

Simple and reliable methods to measure unilateral hip adduction and abduction strength using hand-held dynamometry was described in 2010 by Thorborg et al.13 Since then, several additional studies have confirmed these findings highlighting the clinical usefulness of handheld dynamometry.14–17 One of the advantages of handheld dynamometry is the ease of use without the need for a comprehensive setup, however, for valid and reliable measures the tester must possess enough strength compared to the force output of the patient or athlete to be able to fixate the dynamometer.18 If this is not the case, the dynamometer will move indicating that concentric rather than maximal isometric strength is obtained, leading to a lower strength output.19 Thorborg et al.18 showed how inadequate upper body strength of the tester led to lower tested maximal isometric strength compared to a tester with high upper body strength. One way to overcome this is to externally fixate the handheld dynamometer against a wall14 or using a rigid belt.15,20 which has been applied successfully in several studies. Such a setup may not always be feasible, which calls for alternative ways of estimating hip adduction and abduction strength in strong athletes without the need for external fixation. Healthcare professionals working with athletes have to a wide extent adopted the bilateral hip adduction squeeze test in various forms21 which provides a gross measure of hip adduction strength and function.11,22,23 The long lever hip adduction squeeze test elicits high hip adduction torque,24 and is thus considered appropriate to measure maximal strength17 and to stress the groin tissue.25 The long lever hip adduction has previously been applied to obtain strength profiles of both elite football26 and ice hockey players,11 and to aid secondary prevention of groin injuries.9 Previous studies have only established intra-tester reliability (ICC: 0.92; SEM %: 4.3).17 Similarly, bilateral hip abduction strength can be measured using the long lever press test; a novel test which has been utilized in elite ice hockey players.11 However, determination of intra- and inter-tester reliability is lacking in the literature.

Assessment of rate of force development (RFD), the ability to rapidly produce force over a short period of time,27 may provide value in the management of patients with hip and groin pain beyond measures of maximal strength. In patients who have undergone hip arthroscopy for femoroacetabular impingement syndrome, hip flexion rate of torque development was lower in the operated compared to the non-operated hip despite maximal hip flexion strength being normalized,23 a tendency which is also present in other types of musculoskeletal pain conditions.28 Therefore, assessment of hip adductor and abductor RFD may aid return-to-play decisions, as sports activities such as kicking, skating, and change of direction rely on rapid force development.29–33 Good test-retest reliability of bilateral hip adduction and abduction RFD using the GroinBar testing system (Vald Performance, Albion, Australia) and a user-independent portable dynamometer have been observed.34,35 Both studies applied a short lever arm by placing the force pads between the knees rather than ankles, thereby limiting the torque production across the hip joint17 and compromising detection of groin pain.25

The aim of the present study was to assess intra- and inter-tester reliability of maximal, and explosive strength during the long lever hip adduction squeeze test and the long lever hip abduction press test in healthy adults using a hand-held dynamometer.

METHODS

Study design and subjects

Intra- and inter-tester reliability of maximal isometric strength and rate of force development of 0-100 ms (RFD100) and 0-200 ms (RFD200) was assessed with a hand-held dynamometer during the long lever hip adduction squeeze test17 and a novel long lever bilateral hip abduction press test using a rigid belt.11 All subjects were included by convenience sampling from two different setting. Subjects for the intra-tester part were included from the Physiotherapy Department at Metropolitan University College, Denmark, whereas subjects for the inter-tester part were included from sub-elite sports clubs in the Capital Region of Denmark (Figure 1). All subjects were between 18-40 years old, and subjects included from sport clubs for the inter-tester reliability part had to be injury-free at the time of testing. Exclusion criteria for all subjects were any current pain in the hip and groin region, knee, or low back considered to influence their ability to exert a maximal and rapid muscle contraction.

Figure 1. The flow of participants.

Figure 1.

The reporting adheres to the Proposed Guidelines for Reporting Reliability and Agreement Studies (GRRAS)36 and approval by the Ethics Committee of the Capital Region, Denmark (16041360) was obtained prior to commencement. All subjects gave their written informed consent in accordance with the Declaration of Helsinki.

Testers

All three testers (one for the intra-tester part and two for the inter-tester part) were final year physiotherapist students. The tester involved in the intra-tester part had a previous half year experience with handheld dynamometers but not specifically related to the tests applied in this study, whereas the testers for the inter-tester part had no previous experience with handheld dynamometry before being involved in this study. All testers received 1-2 hours of practice supervised by LI and KT, followed by self-practice for maximum of one week. LI and KT approved all testers prior to data collection.

Data Collection

The force signal for bilateral hip adduction and abduction using a hand-held dynamometer (HHD) were recorded with a sampling frequency of 100 Hz (Hoggan microFET2, Hoggan Scientific L.L.C, Salt Lake City UT, USA). From this maximal isometric strength and rate of force development for 0-100 ms and 0-200 ms (detailed below) was determined. The test procedure for the long lever squeeze test followed a standardized reliable set-up (ICC2.1; 0.90-0.97).17 With the subject in supine position and hip and knees straight (0º flexion), the dynamometer was placed 5 cm proximal to the most prominent point on the medial malleolus of the dominant leg. The participant’s legs were slightly abducted corresponding to the length of the testers forearm and the dynamometer. The forearm and the HHD was placed between the ankles, and the subject was subsequently instructed to perform a bilateral hip adduction squeeze. The bilateral hip abduction press test was conducted with the subject in supine position. The HHD was placed 5 cm proximal to the most prominent point of the lateral malleolus and fixated with a rigid belt around the legs. The participant’s legs were slightly abducted corresponding to the position of the hip adduction squeeze test. The subject was instructed to press against a rigid belt placed around the ankles and the HHD by performing a bilateral hip abduction. During both tests, subjects were instructed to push or press as “fast and hard” as possible, and to keep pushing or pressing until instructed to relax (approximately 3-4 s).27

Both tests consisted of two submaximal trials at 50% and 100% of self-perceived maximum effort, followed by three valid trials, separated by one-minute rest. After each trial subjects were asked to score pain in the hip and groin on an 11-point Numerical Rating Scale (NRS 0-10). The test was terminated in case of pain >3. For the inter-tester part, the two testers were blinded to strength measures obtained by the other tester.

The force data were transmitted from the HHD to a commercial software program (TBS, Hoggan, Scientific L.L.C., Salt Lake City, USA) and extracted to a custom-made spreadsheet (Microsoft Excel, USA) for analyses.14 Force was recorded in Newton (N). RFD100 (100 ms) and RFD200 (200 ms) was calculated as the mean change in N per second in each time interval (100 ms and 200 ms) with the onset threshold of force (t=0 ms) set at 6.7 N above baseline force.27 Maximal isometric strength was determined as the peak value.

The sequence of measurements and testers were randomized, and an identical sequence was used during the retest session. Subjects rested 15 minutes between the test-retest sessions.

Statistical methods

Systematic bias between-sessions (intra-tester) and between-testers (inter-tester) was assessed as differences in mean values using paired t-tests with a significance level set at p<0.05. Relative reliability was assessed as Intraclass Correlation Coefficient (ICC) with a two-way random effects model and absolute agreement definition using the “irr” package in R. Absolute agreement was chosen as this examines the relative reliability without incorporating a systemic error term (this means that the ICC value reflects any systematic variation between testers/sessions, and was thus used because of systematic bias was detected36). The relative reliability was interpreted as poor (ICC<0.50), moderate (0.50≤ICC≤0.75), and good (ICC>0.75).37 Absolute reliability was expressed as 1) the standard error of measurement (SEM) calculated as SDPooled×1ICC,38 and 2) SEM% calculated as:, (SEMmeanpooled)×100.39 Minimal detectable change % (MDC%) was calculated using SEM%, both at the individual level (MDCind % = SEM%×1.96×2) and group level (MDCgroup % = SEM%×1.96×2n , where n is the sample).38,40 Bland-Altman plots were constructed using the “BlandAltmanLeh” package in R. All statistical analyses were calculated in R Studio (v. 3.6.1).

RESULTS

Participants

Fifty-four subjects were recruited. Four subjects were excluded due to technical errors in the software program used for data collection and one subject were excluded due to pain during testing that affected performance. Therefore, a total of 49 subjects were included. Twenty subjects (males: 10; females: 10, mean age ± SD: 25.5 ± 4.2, mean body mass ± SD: 75 ± 12.3, mean height ± SD: 177.7 ± 12.8) were included for intra-tester reliability. Due to loss of data, twenty subjects were included for abduction testing, whereas 19 subjects were included for adduction testing. Twenty-nine male subjects (mean age ± SD: 23.5 ± 5.5, mean body mass ± SD: 89 ± 11.0, mean height ± SD: 187.5 ± 12.5) were included for inter-tester reliability (Figure 1).

Intra-tester reliability

No systematic bias between sessions was observed (p≥0.62). Good intra-tester reliability was observed for peak force and RFD200 for both hip adduction squeeze and hip abduction press (ICC 0.83-0.97), whereas only hip abduction press showed good reliability for RFD100 (ICC 0.76) (Table 1). The absolute intra-tester reliability (SEM %) for peak force, RFD100, and RFD200 ranged from 3.9-7.7 %, 16.9-25.2 %, and 10.5-11.8 %, respectively (Table 1). MDCind % for peak force, RFD100, and RFD200 ranged from 10.9-21.2 %, 47.0-69.9 %, and 29.0-32.7 %, respectively (Table 1). Bland-Altman plots are depicted in Figure 2.

Table 1. Intra-tester reliability of peak force, and rate of force development for hip adduction (n=19) and hip abduction (n=20).

Isometric hip actions Session 1 mean (SD) Session 2
mean (SD)
Difference session 1-⁠session 2 peak [CI 95 %] Paired t-⁠test p-⁠value ICC (2.1) * [CI 95%] SEM SEM % MDCind (%) MDCgroup (%)
MVC – N
HADD 175.3
(48.3)
173.5
(47.3)
1.8
[-7.3; 11.0]
0.68 0.92
(0.81; 0.97]
13.3 7.7 21.2 4.9
HABD 156.2
(33.7)
156.4
(37.8)
-0.2
[-4.6; 4.2]
0.91 0.97
[0.92; 0.99]
6.1 3.9 10.9 2.5
RFD 0-100 – N/s
HADD 700.0
(300.7)
708.0
(282.6)
-7.9
[-132.6; 116.7]
0.89 0.62
[0.23; 0.84]
177.5 25.2 69.9 16.0
HABD 844.1
(327.4)
838.7
(257.9)
5.3
[-91.3; 102.0]
0.91 0.76
[0.49; 0.90]
142.5 16.9 47.0 10.8
RFD 0-200 – N/s
HADD 535.2
(179.3)
526.8 (159.1) 8.5
[--36.1; 53.1]
0.69 0.86
[0.67; 0.94]
62.6 11.8 32.7 7.5
HABD 574.0
(161.3)
581.6
(134.8)
-7.6
[-48.8; 33.6]
0.70 0.83
[0.62; 0.93]
60.5 10.5 29.0 6.7

MVC (Maximal voluntary contraction); Nm (Newton meter); Nm/s (Newton meter/second); ICC (Intraclass Correlation Coefficient); SEM (Standard Error of Measurement); MDCind (Minimal Detectable Change on an individual level); MDCgroup (Minimal Detectable Change on a group level); SD (Standard Deviation); HABD (hip abduction); HADD (hip adduction); RFD (Rate of force development); *ICC used for absolute assessment between session.

Figure 2. Bland-Altman plots for inter-tester reliability.

Figure 2.

Inter-tester reliability

Systematic bias was observed between testers for all tests except adduction squeeze MVC test (Table 2). Good inter-tester reliability was observed for peak force for both hip adduction squeeze and hip abduction press (ICC 0.91-0.93). For rate of force development, all measures showed moderate reliability (ICC 0.5-0.75) (Table 2). The absolute inter-tester reliability (SEM %) for peak force and rate RFD measures ranged from 5.7-6.2 % and 10.8-18.3 %, respectively, while MDCInd(%) ranged from 15.8-17.1 and 30.0-50.8 for peak force and RFD measures, respectively (Table 2). Bland-Altman plots are depicted in Figure 3.

Table 2. Inter-tester reliability of peak force, and rate of force development for hip adduction and hip abduction (n=29).

Isometric
hip actions
Tester 1 mean (SD) Tester 2
mean (SD)
Difference Tester 1-⁠Tester 2 Mean [CI 95%] Paired t-⁠test p-⁠value ICC (2.1) * [CI 95%] SEM SEM % MDCind (%) MDCgroup (%)
MVC – N
HADD 278.3
(57.6)
274.2
(62.3)
4.1
[-4.7; 12.9]
0.35 0.93
[0.85-0.96]
15.7 5.7 15.8 2.9
HABD 190.1
(38.1)
178.9
(36.8)
11.2
[6.4; 16.1]
<0.01 0.91
[0.56-0.97]
11.4 6.2 17.1 3.2
RFD 0-100 - N/s
HADD 1511.2
(360.7)
1245.3
(305.7)
265.8
[159.1; 372.6]
<0.01 0.50
[-0.01-⁠0.77]
252.8 18.3 50.8 9.4
HABD 1187.7
(308.6)
1055.6
(283.0)
132.1
[44.5; 219.6]
<0.01 0.64
[0.30-0.82]
180.6 16.1 44.6 8.3
RFD 0-200 - N/s
HADD 1005.3
(206.2)
900.8
(195.7)
104.5
[62.4; 146.6]
<0.01 0.75
[0.19-0.91]
103.0 10.8 30.0 5.6
HABD 759.9
(167.1)
704.5
(162.2)
50.4
[7.1; 93.6]
0.02 0.73
[0.48-0.87]
85.8 11.8 32.6 6.1

MVC (Maximal voluntary contraction); N (Newton); N/s (Newton/second); ICC (Intraclass Correlation Coefficient); SEM (Standard Error of Measurement); MDCind (Minimal Detectable Change on an individual level); MDCgroup (Minimal Detectable Change on a group level); SD (Standard Deviation); HABD (hip abduction); HADD (hip adduction); RFD (Rate of force development); *ICC with two-way random effects and absolute agreement definition.

Figure 3. Bland-Altman plots for inter-tester reliability.

Figure 3.

Discussion

This study introduces a new and reliable way to measure maximal and explosive bilateral hip abduction strength using a hand-held dynamometer using a test setup unaffected by the tester’s strength. The current findings show that maximal isometric strength can be reliably measured within and between testers with low measurement error in both tests, while late-phase RFD (0-200ms) for both tests also showed good intra-tester reliability. All remaining RFD measures showed moderate reliability but with high imprecision based on the confidence intervals crossing threshold of <0.50 signifying poor reliability, and wide Limits of Agreements. This suggest that measures of maximal isometric hip adduction and abduction strength can be obtained by different testers, whereas late-phase RFD only should be obtained by the same tester as the confidence interval for inter-tester reliability is too large to ensure reliable measurements. The early-phase RFD shows large measurement error regardless of whether this was obtained by the same or different testers, and thus provide little to no utility.

Maximal isometric strength

In elite sport settings there is often a need to efficiently measure athletes’ lower body strength in a short time frame, such as during periodic testing.11,41 This can be achieved by using handheld dynamometers which easily accommodate various testing setups, such as unilateral hip adduction (ICC: 0.93) and abduction (ICC: 0.97).13 In strong athletes, external fixation may be needed dependent on the tester’s upper body strength to obtain valid measures,15,18 but this is not always feasible due to time constraints when large cohorts need testing. An alternative to unilateral testing of the hip is the long lever hip adduction squeeze test and the bilateral hip abduction press test. Both tests are quick and can easily be applied in even strong athletes without the need for an external fixation setup, thus providing a feasible way of measuring hip adduction and abduction strength in athletes. The current findings for intra-tester reliability of the long lever squeeze test are consistent with previous findings reported by Light et. al. (ICC: 0.92; SEM %: 4.3).17 Other hip squeeze test variations have shown similar reliability using either a sphygmometer (ICC: 0.81-0.94; SEM %: 1.60-3.27)42,43 or the Groinbar (ICC: 0.85-0.94; SEM %: 8.2).34,44 The inter-tester reliability of the long lever squeeze test has not yet been examined, but the current findings are consistent with those reported when using other variations of the squeeze test (short lever squeeze test, ICC: 0.91-0.92)45,46 and peak force measured unilaterally (ICC:0.92-0.94).15,47 This study is the first to examine intra- and inter-tester reliability of the long lever hip abduction press test. The current data are comparable to previous literature reporting on reliability for hip abduction strength testing, using a bilateral short-lever test in the Groinbar (ICC: 0.82)34 or performed in a user-independent portable device (ICC: 0.91).35

Rate of Force development

The present study is the first to establish reliability data on RFD measures in the long-lever squeeze test and the novel hip abduction press test. These data indicate that late-phase RFD (0-200ms) showed good intra-tester reliability for both tests, while remaining RFD measures showed poor reliability. Two previous studies have reported reliability for RFD measured during bilateral hip adduction squeeze and abduction press tests; both studies applied a short lever position, precluding direct comparison with the present study. Desmyttere et al. found moderate to good intra-tester reliability of peak RFD using a 200 ms moving average during bilateral short lever adduction and abduction testing using the Groinbar (ICC 0.81 [95 % CI: 0.65-0.90] and 0.68 [95 % CI: 0.42-0.83]).34 In contrast to the present study, good reliability has been reported for early-phase RFD (0-100 ms) using a user-independent device to measure bilateral hip adduction and abduction strength in the short lever position, while early-phase RFD has also showed good reliability in both abduction and adduction when performed unilaterally.14 These discrepancies in testing properties may be explained by different set-ups, but suggest that, if explosive bilateral hip adduction and abduction strength in the long-lever position is of interest across athletes or over time, this should be obtained by the same tester and only late-phase RFD should be considered. The lower reliability for early-phase RFD in our study could be explained by the timeframe of 0-100 ms being too short to coordinate a simultaneous fast contraction with both legs.

Application to clinical practice

The procedure examined in this study is feasible to be included in clinical practice, as a quick and simple method for testing maximal isometric strength and late-phase explosive strength in strong athletes without potential bias related to the tester size or strength.15,18 In research settings, evaluation of changes is often of interest at a group level. The MDCgroup% reported in the present study is calculated based on 20 participants for the intra-tester and 29 participants for the inter-tester part. Using an equivalent sample size, changes at group level exceeding 5 % for peak force and 7.5 % for late-phase RFD (0-200 ms) can be detected with 95 % certainty,40 when using both a single- and multiple-tester setup. When applied on individual patients or athletes in the clinical setting, changes would have to exceed ~10-20 % for peak force and ~30 % for late-phase RFD (0-200 ms) to be detected with 95 % certainty. The is further indicated by the width of the Limits of Agreement of the Bland Altman plot, suggesting that high uncertainty between two measures is expected. Although these numbers are high they should be considered in relation to findings in injured athletes. As an example, prior-season groin pain lasting more than six weeks, is related to in average 19 % decrease in peak strength during the long lever squeeze test in currently uninjured players.8 For explosive muscle strength, even larger deficits may be expected; Nunes et al. observed a decrease in explosive strength of 33 % in the hip abductors in females with patellofemoral pain.48 However, explosive hip adduction and abduction strength and its relation to groin pain have not yet been established.

Methodological considerations and Limitations

A limitation in the present study is the systematic bias observed in the inter-tester data, which could have been affected by dynamometer placement, instruction, or encouragement during testing. However, it might be possible to minimize these differences by further standardization of testing procedures and more focus on tester calibration. Since the adductor muscle force angle depends on the testers forearm length, this may also contribute to the systematic bias, thus influencing inter-tester reliability. However, the authors did not collect data related to forearm length, thus it cannot be concluded if this affected the reliability in the present study. A further limitation is that only healthy subjects were included. Thus, future studies should be performed including athletes with groin pain, to understand if groin pain may affect reliability.

Conclusion

Assessment of maximal isometric strength in hip adduction squeeze and abduction press test showed good intra- and inter-tester reliability, whereas only 0-200 ms rate of force development demonstrated good intra-tester reliability of both tests. Therefore, rate of force development should preferably be conducted by the same tester, while this is less important for isometric peak torque.

Conflicts of interest

The authors report no conflicts of interest.

References

  1. Esteve Ernest, Clausen Mikkel Bek, Rathleff Michael Skovdal, Vicens-Bordas Jordi, Casals Martí, Palahí-Alcàcer Albert, Hölmich Per, Thorborg Kristian. Scandinavian Journal of Medicine & Science in Sports. 5. Vol. 30. Wiley; Prevalence and severity of groin problems in Spanish football: A prospective study beyond the time-loss approach; pp. 914–921. [DOI] [PubMed] [Google Scholar]
  2. Harøy Joar, Clarsen Ben, Thorborg Kristian, Hölmich Per, Bahr Roald, Andersen Thor Einar. The American Journal of Sports Medicine. 6. Vol. 45. SAGE Publications; Groin problems in male soccer players are more common than previously reported; pp. 1304–1308. [DOI] [PubMed] [Google Scholar]
  3. Elite ice hockey goalkeepers have a high prevalence of hip and groin problems associated with decreased sporting function: A single-season prospective cohort study. Wörner Tobias, Clarsen Benjamin, Thorborg Kristian, Eek Frida. Dec 1;2019 Orthopaedic Journal of Sports Medicine. 7(12):2325967119892586. doi: 10.1177/2325967119892586. doi: 10.1177/2325967119892586. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Mosler Andrea B., Weir Adam, Serner Andreas, Agricola Rintje, Eirale Cristiano, Farooq Abdulaziz, Bakken Arnhild, Thorborg Kristian, Whiteley Rod J., Hölmich Per, Bahr Roald, Crossley Kay M. The American Journal of Sports Medicine. 6. Vol. 46. SAGE Publications; Musculoskeletal screening tests and bony hip morphology cannot identify male professional soccer players at risk of groin injuries: A 2-year prospective cohort study; pp. 1294–1305. [DOI] [PubMed] [Google Scholar]
  5. Esteve Ernest, Casals Marti, Saez Marc, Rathleff Michael Skovdal, Clausen Mikkel Bek, Vicens-Bordas Jordi, Hölmich Per, Pizzari Tania, Thorborg Kristian. British Journal of Sports Medicine. 9. Vol. 56. BMJ; Past-season, pre-season and in-season risk assessment of groin problems in male football players: a prospective full-season study; pp. 484–489. [DOI] [PubMed] [Google Scholar]
  6. Tyler Timothy F., Nicholas Stephen J., Campbell Richard J., McHugh Malachy P. The American Journal of Sports Medicine. 2. Vol. 29. SAGE Publications; The association of hip strength and flexibility with the incidence of adductor muscle strains in professional ice hockey players; pp. 124–128. [DOI] [PubMed] [Google Scholar]
  7. Hip adductor muscle strength is reduced preceding and during the onset of groin pain in elite junior Australian football players. Crow Justin F., Pearce Alan J., Veale James P., VanderWesthuizen Dan, Coburn Paul T., Pizzari Tania. Mar;2010 Journal of Science and Medicine in Sport. 13(2):202–204. doi: 10.1016/j.jsams.2009.03.007. doi: 10.1016/j.jsams.2009.03.007. [DOI] [PubMed] [Google Scholar]
  8. Preseason adductor squeeze strength in 303 spanish male soccer athletes: A cross-sectional study. Esteve Ernest, Rathleff Michael Skovdal, Vicens-Bordas Jordi, Clausen Mikkel Bek, Hölmich Per, Sala Lluís, Thorborg Kristian. Jan 1;2018 Orthopaedic Journal of Sports Medicine. 6(1):232596711774727. doi: 10.1177/2325967117747275. doi: 10.1177/2325967117747275. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Weekly screening of youth male football players: a 14-week longitudinal investigation of interactions between groin pain and long lever adductor squeeze strength. DeLang Matthew D., Garrison J. Craig, Hannon Joseph P., Ishøi Lasse, Thorborg Kristian. Mar;2023 Journal of Science and Medicine in Sport. 26(3):159–163. doi: 10.1016/j.jsams.2023.02.003. doi: 10.1016/j.jsams.2023.02.003. [DOI] [PubMed] [Google Scholar]
  10. In-season monitoring of hip and groin strength, health and function in elite youth soccer: Implementing an early detection and management strategy over two consecutive seasons. Wollin Martin, Thorborg Kristian, Welvaert Marijke, Pizzari Tania. Oct;2018 Journal of Science and Medicine in Sport. 21(10):988–993. doi: 10.1016/j.jsams.2018.03.004. doi: 10.1016/j.jsams.2018.03.004. [DOI] [PubMed] [Google Scholar]
  11. Five-second squeeze testing in 333 professional and semiprofessional male ice hockey players: How are hip and groin symptoms, strength, and sporting function related? Wörner Tobias, Thorborg Kristian, Eek Frida. Feb 1;2019 Orthopaedic Journal of Sports Medicine. 7(2):232596711982585. doi: 10.1177/2325967119825858. doi: 10.1177/2325967119825858. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Thorborg Kristian, Reiman Michael P., Weir Adam, Kemp Joanne L., Serner Andreas, Mosler Andrea B., HÖlmich Per. Journal of Orthopaedic & Sports Physical Therapy. 4. Vol. 48. Journal of Orthopaedic & Sports Physical Therapy (JOSPT); Clinical examination, diagnostic imaging, and testing of athletes with groin pain: An evidence-based approach to effective management; pp. 239–249. [DOI] [PubMed] [Google Scholar]
  13. Clinical assessment of hip strength using a hand-held dynamometer is reliable. Thorborg K., Petersen J., Magnusson S. P., Hölmich P. 2010Scandinavian Journal of Medicine & Science in Sports. 20(3):493–501. doi: 10.1111/j.1600-0838.2009.00958.x. doi: 10.1111/j.1600-0838.2009.00958.x. [DOI] [PubMed] [Google Scholar]
  14. Measures of hip muscle strength and rate of force development using a fixated handheld dynamometer: Intra-tester intra-day reliability of a clinical set-up. Ishøi Lasse, Hölmich Per, Thorborg Kristian. Sep;2019 International Journal of Sports Physical Therapy. 14(5):715–723. doi: 10.26603/ijspt20190715. doi: 10.26603/ijspt20190715. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable. Thorborg Kristian, Bandholm Thomas, Hölmich Per. 2013Knee Surgery, Sports Traumatology, Arthroscopy. 21(3):550–555. doi: 10.1007/s00167-012-2115-2. doi: 10.1007/s00167-012-2115-2. [DOI] [PubMed] [Google Scholar]
  16. Assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: A reliability and validity study. Mentiplay Benjamin F., Perraton Luke G., Bower Kelly J., Adair Brooke, Pua Yong-Hao, Williams Gavin P., McGaw Rebekah, Clark Ross A. Oct 28;2015 PLoS ONE. 10(10):e0140822. doi: 10.1371/journal.pone.0140822. doi: 10.1371/journal.pone.0140822. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. The precision and torque production of common hip adductor squeeze tests used in elite football. Light N., Thorborg K. Nov;2016 Journal of Science and Medicine in Sport. 19(11):888–892. doi: 10.1016/j.jsams.2015.12.009. doi: 10.1016/j.jsams.2015.12.009. [DOI] [PubMed] [Google Scholar]
  18. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength. Thorborg K., Bandholm T., Schick M., Jensen J., Hölmich P. 2013Scandinavian Journal of Medicine & Science in Sports. 23(4):487–493. doi: 10.1111/j.1600-0838.2011.01405.x. doi: 10.1111/j.1600-0838.2011.01405.x. [DOI] [PubMed] [Google Scholar]
  19. On the shape of the force-velocity relationship in skeletal muscles: The linear, the hyperbolic, and the double-hyperbolic. Alcazar Julian, Csapo Robert, Ara Ignacio, Alegre Luis M. Jun 19;2019 Frontiers in Physiology. 10:769. doi: 10.3389/fphys.2019.00769. doi: 10.3389/fphys.2019.00769. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. The influence of hamstring muscle peak torque and rate of torque development for sprinting performance in football players: A cross-sectional study. Ishøi Lasse, Aagaard Per, Nielsen Mathias F., Thornton Kasper B., Krommes Kasper K., Hölmich Per, Thorborg Kristian. May 1;2019 International Journal of Sports Physiology and Performance. 14(5):665–673. doi: 10.1123/ijspp.2018-0464. doi: 10.1123/ijspp.2018-0464. [DOI] [PubMed] [Google Scholar]
  21. Hip and groin injury management in English youth football: a survey of 64 professional academies. Light Neil, Smith Neal, Delahunt Eamonn, Thorborg Kristian. Feb 23;2018 Science and Medicine in Football. 2(2):133–140. doi: 10.1080/24733938.2018.1441536. doi: 10.1080/24733938.2018.1441536. [DOI] [Google Scholar]
  22. Copenhagen five-second squeeze: a valid indicator of sports-related hip and groin function. Thorborg K, Branci S, Nielsen M P, Langelund M T, Hölmich P. 2017British Journal of Sports Medicine. 51(7):594–599. doi: 10.1136/bjsports-2016-096675. doi: 10.1136/bjsports-2016-096675. [DOI] [PubMed] [Google Scholar]
  23. Maximal hip muscle strength and rate of torque development 6–30 months after hip arthroscopy for femoroacetabular impingement syndrome: A cross-sectional study. Ishøi Lasse, Thorborg Kristian, Kemp Joanne L., Reiman Michael P., Hölmich Per. Nov;2021 Journal of Science and Medicine in Sport. 24(11):1110–1115. doi: 10.1016/j.jsams.2021.05.006. doi: 10.1016/j.jsams.2021.05.006. [DOI] [PubMed] [Google Scholar]
  24. Hip adduction strength and provoked groin pain: A comparison of long-lever squeeze testing using the ForceFrame and the Copenhagen 5-Second-Squeeze test. Nielsen Mathias F., Thorborg Kristian, Krommes Kasper, Thornton Kasper B., Hölmich Per, Peñalver Juan J.J., Ishøi Lasse. May;2022 Physical Therapy in Sport. 55:28–36. doi: 10.1016/j.ptsp.2022.02.002. doi: 10.1016/j.ptsp.2022.02.002. [DOI] [PubMed] [Google Scholar]
  25. Resisted adduction in hip neutral is a superior provocation test to assess adductor longus pain: An experimental pain study. Drew M. K., Palsson T. S., Izumi M., Hirata R. P., Lovell G., Chiarelli P., Osmotherly P. G., Graven-Nielsen T. 2016Scandinavian Journal of Medicine & Science in Sports. 26(8):967–974. doi: 10.1111/sms.12529. doi: 10.1111/sms.12529. [DOI] [PubMed] [Google Scholar]
  26. Rapid spike in hip adduction strength in early adolescent footballers: A study of 125 elite male players from youth to senior. Light Neil, Thorborg Kristian, Krommes Kasper, Nielsen Mathias F., Thornton Kasper B., Hölmich Per, Penalver Juan J.J., Ishøi Lasse. Sep 1;2022 International Journal of Sports Physiology and Performance. 17(9):1407–1414. doi: 10.1123/ijspp.2022-0025. doi: 10.1123/ijspp.2022-0025. [DOI] [PubMed] [Google Scholar]
  27. Maffiuletti Nicola A., Aagaard Per, Blazevich Anthony J., Folland Jonathan, Tillin Neale, Duchateau Jacques. European Journal of Applied Physiology. 6. Vol. 116. Springer Science and Business Media LLC; Rate of force development: physiological and methodological considerations; pp. 1091–1116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Rapid muscle activation and force capacity in conditions of chronic musculoskeletal pain. Andersen Lars L., Holtermann Andreas, Jørgensen Marie B., Sjøgaard Gisela. Dec;2008 Clinical Biomechanics. 23(10):1237–1242. doi: 10.1016/j.clinbiomech.2008.08.002. doi: 10.1016/j.clinbiomech.2008.08.002. [DOI] [PubMed] [Google Scholar]
  29. Asymmetry in quadriceps rate of force development as a functional outcome measure in TKA. Maffiuletti Nicola A., Bizzini Mario, Widler Katharina, Munzinger Urs. Jan;2010 Clinical Orthopaedics & Related Research. 468(1):191–198. doi: 10.1007/s11999-009-0978-4. doi: 10.1007/s11999-009-0978-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Hip adductor activations during run-to-cut manoeuvres in compression shorts: implications for return to sport after groin injury. Chaudhari Ajit M.W., Jamison Steven T., McNally Michael P., Pan Xueliang, Schmitt Laura C. Mar 26;2014 Journal of Sports Sciences. 32(14):1333–1340. doi: 10.1080/02640414.2014.889849. doi: 10.1080/02640414.2014.889849. [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Adductor longus mechanics during the maximal effort soccer kick. Charnock Brian L., Lewis Cara L., Garrett William E., Jr., Queen Robin M. Sep;2009 Sports Biomechanics. 8(3):223–234. doi: 10.1080/14763140903229500. doi: 10.1080/14763140903229500. [DOI] [PubMed] [Google Scholar]
  32. Brophy Robert H., Backus Sherry I., Pansy Brian S., Lyman Stephen, Williams Riley J. Journal of Orthopaedic & Sports Physical Therapy. 5. Vol. 37. Journal of Orthopaedic & Sports Physical Therapy (JOSPT); Lower extremity muscle activation and alignment during the soccer instep and side-foot kicks; pp. 260–268. [DOI] [PubMed] [Google Scholar]
  33. Hip adductor muscle function in forward skating. Chang Ryan, Turcotte Rene, Pearsall David. Sep;2009 Sports Biomechanics. 8(3):212–222. doi: 10.1080/14763140903229534. doi: 10.1080/14763140903229534. [DOI] [PubMed] [Google Scholar]
  34. Test-retest reliability of a hip strength assessment system in varsity soccer players. Desmyttere Gauthier, Gaudet Sylvain, Begon Mickael. May;2019 Physical Therapy in Sport. 37:138–143. doi: 10.1016/j.ptsp.2019.03.013. doi: 10.1016/j.ptsp.2019.03.013. [DOI] [PubMed] [Google Scholar]
  35. A New portable device to reliably measure maximal strength and rate of force development of hip adduction and abduction. Gonçalves Basílio A.M., Mesquita Ricardo N.O., Tavares Francisco, Brito João, Correia Paulo, Santos Paulo, Mil-Homens Pedro. Jan 22;2021 Journal of Strength and Conditioning Research. 36(9):2465–2471. doi: 10.1519/jsc.0000000000003872. doi: 10.1519/jsc.0000000000003872. [DOI] [PubMed] [Google Scholar]
  36. Guidelines for reporting reliability and agreement studies (GRRAS) Kottner Jan, Audige Laurent, Brorson Stig, Donner Allan, Gajewski Byron J., Hróbjartsson Asbjørn, Roberts Chris, Shoukri Mohamed, Streiner David L. Jun;2011 International Journal of Nursing Studies. 48(6):661–671. doi: 10.1016/j.ijnurstu.2011.01.016. doi: 10.1016/j.ijnurstu.2011.01.016. [DOI] [PubMed] [Google Scholar]
  37. Portney L.G. Foundations of Clinical Research: Applications to Evidence-Based Practice. F.A. Davis; [Google Scholar]
  38. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. Weir Joseph P. 2005The Journal of Strength and Conditioning Research. 19(1):231–240. doi: 10.1519/15184.1. doi: 10.1519/15184.1. [DOI] [PubMed] [Google Scholar]
  39. How to assess the reliability of measurements in rehabilitation. Lexell Jan E., Downham David Y. Sep;2005 American Journal of Physical Medicine & Rehabilitation. 84(9):719–723. doi: 10.1097/01.phm.0000176452.17771.20. doi: 10.1097/01.phm.0000176452.17771.20. [DOI] [PubMed] [Google Scholar]
  40. Reproducibility and responsiveness of evaluative outcome measures. Theoretical considerations illustrated by an empirical example. de Vet Henrica C. W., Bouter Lex M., Bezemer P. Dick, Beurskens Anna J. H. M. Oct;2001 International Journal of Technology Assessment in Health Care. 17(4):479–487. doi: 10.1017/s0266462301107038. doi: 10.1017/s0266462301107038. [DOI] [PubMed] [Google Scholar]
  41. Hamstring and quadriceps muscle Strength in youth to senior elite soccer: A cross-sectional study including 125 players. Ishøi Lasse, Krommes Kasper, Nielsen Mathias F., Thornton Kasper B., Hölmich Per, Aagaard Per, Penalver Juan J.J., Thorborg Kristian. Oct 1;2021 International Journal of Sports Physiology and Performance. 16(10):1538–1544. doi: 10.1123/ijspp.2020-0713. doi: 10.1123/ijspp.2020-0713. [DOI] [PubMed] [Google Scholar]
  42. Intrarater reliability of the adductor squeeze test in Gaelic games athletes. Delahunt Eamonn, McEntee Barry L., Kennelly Colm, Green Brian S., Coughlan Garrett F. May 1;2011 Journal of Athletic Training. 46(3):241–245. doi: 10.4085/1062-6050-46.3.241. doi: 10.4085/1062-6050-46.3.241. [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Hip flexibility and strength measures: reliability and association with athletic groin pain. Malliaras P, Hogan A, Nawrocki A, Crossley K, Schache A. Mar 11;2009 British Journal of Sports Medicine. 43(10):739–744. doi: 10.1136/bjsm.2008.055749. doi: 10.1136/bjsm.2008.055749. [DOI] [PubMed] [Google Scholar]
  44. Measurement properties of an adductor strength-assessment system in professional Australian footballers. Ryan Samuel, Kempton Thomas, Pacecca Emidio, Coutts Aaron J. Feb;2019 International Journal of Sports Physiology and Performance. 14(2):256–259. doi: 10.1123/ijspp.2018-0264. doi: 10.1123/ijspp.2018-0264. [DOI] [PubMed] [Google Scholar]
  45. The inter-tester reliability of the squeeze and bent-knee-fall-out tests in elite academy football players. O'Brien James, Santner Emanuel, Finch Caroline F. Nov;2018 Physical Therapy in Sport. 34:8–13. doi: 10.1016/j.ptsp.2018.08.004. doi: 10.1016/j.ptsp.2018.08.004. [DOI] [PubMed] [Google Scholar]
  46. The validity and reliability of the sphygmomanometer for hip strength assessment in Australian football players. Toohey Liam Anthony, de Noronha Marcos, Taylor Carolyn, Thomas James. 2018Physiotherapy Theory and Practice. 34(2):131–136. doi: 10.1080/09593985.2017.1374492. doi: 10.1080/09593985.2017.1374492. [DOI] [PubMed] [Google Scholar]
  47. Reliability of a new stabilized dynamometer system for the evaluation of hip strength. Tourville Timothy W., Smith Helen C., Shultz Sandra J., Vacek Pamela M., Slauterbeck James R., Johnson Robert J., Beynnon Bruce D. 2013Sports Health: A Multidisciplinary Approach. 5(2):129–136. doi: 10.1177/1941738112459486. doi: 10.1177/1941738112459486. [DOI] [PMC free article] [PubMed] [Google Scholar]
  48. Hip rate of force development and strength are impaired in females with patellofemoral pain without signs of altered gluteus medius and maximus morphology. Nunes Guilherme S., Barton Christian John, Serrão Fábio Viadanna. Feb;2018 Journal of Science and Medicine in Sport. 21(2):123–128. doi: 10.1016/j.jsams.2017.05.014. doi: 10.1016/j.jsams.2017.05.014. [DOI] [PubMed] [Google Scholar]

Articles from International Journal of Sports Physical Therapy are provided here courtesy of North American Sports Medicine Institute