Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1983 Apr;67(4):255–258. doi: 10.1136/bjo.67.4.255

Intraocular lens power calculation for planned ametropia: a clinical study.

J S Hillman
PMCID: PMC1040029  PMID: 6830743

Abstract

A prospective series of 25 eyes received an intraocular lens (IOL) of power calculated for planned ametropia, by means of the formulae of R. D. Binkhorst, from data of axial length, corneal curvature, and postoperative anterior chamber depth. All the postoperative refractions were within the +/- 2 D range from the predicted refraction, confirming the clinical value of such calculation. A retrospective study of 100 eyes which had received a +19 D power Binkhorst IOL showed a wide range of change in refraction extending up to the +/- 6 D range, indicating that a 'standard' power IOL cannot be relied upon to reproduce the preoperative refraction. Calculation of IOL power from biometric data is essential when controlled postoperative ametropia is required.

Full text

PDF
255

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Binkhorst R. D. Pitfalls in the determination of intraocular lens power without ultrasound. Ophthalmic Surg. 1976 Fall;7(3):69–82. [PubMed] [Google Scholar]
  2. Clevenger C. E. Clinical prediction versus ultrasound measurement of IOL power. J Am Intraocul Implant Soc. 1978 Oct;4(4):222–224. doi: 10.1016/s0146-2776(78)80100-1. [DOI] [PubMed] [Google Scholar]
  3. Hillman J. S. Intraocular lens power calculation for emmetropia: a clinical study. Br J Ophthalmol. 1982 Jan;66(1):53–56. doi: 10.1136/bjo.66.1.53. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Hillman J. S. The computer calculation of intraocular lens power. A clinical study. Trans Ophthalmol Soc U K. 1980 Apr;100(Pt 1):222–228. [PubMed] [Google Scholar]
  5. Johns G. E. Clinical evaluation of the DBR A-scan unit. J Am Intraocul Implant Soc. 1979 Jul;5(3):213–216. doi: 10.1016/s0146-2776(79)80113-5. [DOI] [PubMed] [Google Scholar]
  6. Kraff M. C., Sanders D. R., Lieberman H. L. Determination of intraocular lens power: a comparison with and without ultrasound. Ophthalmic Surg. 1978 Feb;9(1):81–84. [PubMed] [Google Scholar]
  7. Maloney W. F., Kratz R. P., Mazzocco T. R., Davidson B. Posterior chamber intraocular lens power calculation in 441 cases. J Am Intraocul Implant Soc. 1979 Oct;5(4):349–349. doi: 10.1016/s0146-2776(79)80102-0. [DOI] [PubMed] [Google Scholar]
  8. Roper-Hall M. J. Cataract surgery. Br Med J (Clin Res Ed) 1982 Jul 3;285(6334):2–3. doi: 10.1136/bmj.285.6334.2. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES