Abstract
A grid system is described which may be superimposed upon stereoscopic pairs of optic disc photographs. This grid system allowed reproducible inter- and intraobserver measurements of the cup/disc (C/D) ratio. The surface contour of the optic disc was not clear-cut in approximately 10% of the population studied, which led to a reduction in reproducibility of the measurement made within the group as a whole. As a result it was found that a large increase in the C/D ratio would have to occur for such change to be of statistical significance. Even with an optic grid as a reference system the serial measurements of the C/D ratio are unlikely to be of value in the management of patients with chronic glaucoma.
Full text
PDF





Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Gloster J., Parry D. G. Use of photographs for measuring cupping in the optic disc. Br J Ophthalmol. 1974 Oct;58(10):850–862. doi: 10.1136/bjo.58.10.850. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gloster J. Quantitative relationship between cupping of the optic disc and visual field loss in chronic simple glaucoma. Br J Ophthalmol. 1978 Oct;62(10):665–669. doi: 10.1136/bjo.62.10.665. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hitchings R. A., Spaeth G. L. The optic disc in glaucoma II: correlation of the appearance of the optic disc with the visual field. Br J Ophthalmol. 1977 Feb;61(2):107–113. doi: 10.1136/bjo.61.2.107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hollows F. C., Graham P. A. Intra-ocular pressure, glaucoma, and glaucoma suspects in a defined population. Br J Ophthalmol. 1966 Oct;50(10):570–586. doi: 10.1136/bjo.50.10.570. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hollows F. C., McGuiness R. The size of the optic cup. Trans Ophthalmol Soc Aust. 1966;25:33–38. [PubMed] [Google Scholar]
- Hoskins H. D., Jr, Gelber E. C. Optic disk topography and visual field defects in patients with increased intraocular pressure. Am J Ophthalmol. 1975 Aug;80(2):284–290. doi: 10.1016/0002-9394(75)90146-4. [DOI] [PubMed] [Google Scholar]
- Pederson J. E., Anderson D. R. The mode of progressive disc cupping in ocular hypertension and glaucoma. Arch Ophthalmol. 1980 Mar;98(3):490–495. doi: 10.1001/archopht.1980.01020030486010. [DOI] [PubMed] [Google Scholar]
- Schwartz J. T. Methodologic differences and measurement of cup-disc ratio: an epidemiologic assessment. Arch Ophthalmol. 1976 Jul;94(7):1101–1105. doi: 10.1001/archopht.1976.03910040021004. [DOI] [PubMed] [Google Scholar]
- Shaffer R. N., Ridgway W. L., Brown R., Kramer S. G. The use of diagrams to record changes in glaucomatous disks. Am J Ophthalmol. 1975 Sep;80(3 Pt 1):460–464. doi: 10.1016/0002-9394(75)90534-6. [DOI] [PubMed] [Google Scholar]
- Sommer A., Pollack I., Maumenee A. E. Optic disc parameters and onset of glaucomatous field loss. I. Methods and progressive changes in disc morphology. Arch Ophthalmol. 1979 Aug;97(8):1444–1448. doi: 10.1001/archopht.1979.01020020106002. [DOI] [PubMed] [Google Scholar]