Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1983 Aug;67(8):512–516. doi: 10.1136/bjo.67.8.512

Changes in differential threshold in patients with glaucoma during prolonged perimetry.

A Heijl, S M Drance
PMCID: PMC1040109  PMID: 6871143

Abstract

Patients with chronic open-angle glaucoma and others suspected of having glaucoma were subjected to continuous contrast threshold measurement by automatic and manual perimetric techniques. The results show that an increase of contrast threshold over time is a frequent finding in glaucoma patients and that this increment can be large, especially at points close to existing field defects. it is reproducible and independent of background illumination and can be demonstrated with both automatic and manual testing, but it is larger in the automatic than in the manual mode of testing. The results may have some important implications for visual field testing in glaucoma.

Full text

PDF
512

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Enoch J. M., Berger R., Birns R. A static perimetric technique believed to test receptive field properties: extension and verification of the analysis. Doc Ophthalmol. 1970 Dec 21;29(1):127–153. doi: 10.1007/BF02346235. [DOI] [PubMed] [Google Scholar]
  2. Enoch J. M. Quantitative layer-by-layer perimetry. Invest Ophthalmol Vis Sci. 1978 Mar;17(3):208–257. [PubMed] [Google Scholar]
  3. FANKHAUSER F., ENOCH J. M. The effects of blur upon perimetric thresholds. A method for determining a quantitative estimate of retinal contour. Arch Ophthalmol. 1962 Aug;68:240–251. doi: 10.1001/archopht.1962.00960030244016. [DOI] [PubMed] [Google Scholar]
  4. Heijl A., Krakau C. E. An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases. Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1975 Oct 17;197(1):13–23. doi: 10.1007/BF00506636. [DOI] [PubMed] [Google Scholar]
  5. Heijl A. Time changes of contrast thresholds during automatic perimetry. Acta Ophthalmol (Copenh) 1977 Aug;55(4):696–708. doi: 10.1111/j.1755-3768.1977.tb05668.x. [DOI] [PubMed] [Google Scholar]
  6. Holmin C., Krakau C. E. Variability of glaucomatous visual field defects in computerized perimetry. Albrecht Von Graefes Arch Klin Exp Ophthalmol. 1979 Jun 15;210(4):235–250. [PubMed] [Google Scholar]
  7. Sunga R. N., Enoch J. M. Further perimetric analysis of patients with lesions of the visual pathways. Am J Ophthalmol. 1970 Sep;70(3):403–422. doi: 10.1016/0002-9394(70)90101-7. [DOI] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES