Abstract
The minimum significant (p = 0.05 level) detectable change noted on measuring anterior chamber depth by a photographic method was found to be 7% either way from the mean. The minimum significant change for a peripheral chamber depth 5 mm from the optic axis was found to be 25% either way.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Coakes R. L., Lloyd-Jones D., Hitchings R. A. Anterior chamber volume. Its measurement and clinical application. Trans Ophthalmol Soc U K. 1979 Apr;99(1):78–81. [PubMed] [Google Scholar]
- Haimann M. H., Phelps C. D. Prophylactic timolol for the prevention of high intraocular pressure after cataract extraction. A randomized, prospective, double-blind trial. Ophthalmology. 1981 Mar;88(3):233–238. doi: 10.1016/s0161-6420(81)35053-2. [DOI] [PubMed] [Google Scholar]
- Hitchings R. A., Powell D. J. Pilocarpine and narrow-angle glaucoma. Trans Ophthalmol Soc U K. 1981;101(Pt 2):214–217. [PubMed] [Google Scholar]
- JONES R. F., MAURICE D. M. A SIMPLE PHOTOGRAPHIC METHOD OF MEASURING THE VOLUME OF THE ANTERIOR CHAMBER. Exp Eye Res. 1963 Jul;2:233–236. doi: 10.1016/s0014-4835(63)80041-x. [DOI] [PubMed] [Google Scholar]
- Johnson S. B., Coakes R. L., Brubaker R. F. A simple photogrammetric method of measuring anterior chamber volume. Am J Ophthalmol. 1978 Apr;85(4):469–474. doi: 10.1016/s0002-9394(14)75243-2. [DOI] [PubMed] [Google Scholar]
- Mapstone R. Acute shallowing of the anterior chamber. Br J Ophthalmol. 1981 Jul;65(7):446–451. doi: 10.1136/bjo.65.7.446. [DOI] [PMC free article] [PubMed] [Google Scholar]
- TORNQUIST R. Peripheral chamber depth in shallow anterior chamber. Br J Ophthalmol. 1959 Mar;43(3):169–176. doi: 10.1136/bjo.43.3.169. [DOI] [PMC free article] [PubMed] [Google Scholar]