A comparison of postoperative refractive results with and without intraocular lens power calculation.

S M Thompson, V Mohan-Roberts
PMCID: PMC1040898  PMID: 3947597

Abstract

Sixty-five patients underwent intracapsular cataract extraction with implantation of Binkhorst iris-clip intraocular lenses (IOLs). For 31 patients the IOL was of a standard power. Thirty-four patients had axial length measurement and keratometry preoperatively, and IOLs calculated to produce emmetropia or 1 dioptre of myopia were implanted. There was no significant difference in the range of postoperative refractive results between the two groups.

Full text

PDF
22

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Binkhorst C. D. Power of the prepupillary pseudophakos. Br J Ophthalmol. 1972 Apr;56(4):332–337. doi: 10.1136/bjo.56.4.332. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Clevenger C. E. Clinical prediction versus ultrasound measurement of IOL power. J Am Intraocul Implant Soc. 1978 Oct;4(4):222–224. doi: 10.1016/s0146-2776(78)80100-1. [DOI] [PubMed] [Google Scholar]
  3. Colenbrander M. C. Calculation of the power of an iris clip lens for distant vision. Br J Ophthalmol. 1973 Oct;57(10):735–740. doi: 10.1136/bjo.57.10.735. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Hillman J. S. Intraocular lens power calculation for planned ametropia: a clinical study. Br J Ophthalmol. 1983 Apr;67(4):255–258. doi: 10.1136/bjo.67.4.255. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Hillman J. S. The selection of intraocular lens power by calculation and by reference to the refraction--a clinical study. Trans Ophthalmol Soc U K. 1982;102(Pt 4):495–497. [PubMed] [Google Scholar]
  6. Hoffer K. J. Accuracy of ultrasound intraocular lens calculation. Arch Ophthalmol. 1981 Oct;99(10):1819–1823. doi: 10.1001/archopht.1981.03930020693014. [DOI] [PubMed] [Google Scholar]
  7. Huber C., Binkhorst C. D. Iseikonic lens implantation in anisometropia. J Am Intraocul Implant Soc. 1979 Jul;5(3):194–202. doi: 10.1016/s0146-2776(79)80109-3. [DOI] [PubMed] [Google Scholar]
  8. Johns G. E. Clinical evaluation of the DBR A-scan unit. J Am Intraocul Implant Soc. 1979 Jul;5(3):213–216. doi: 10.1016/s0146-2776(79)80113-5. [DOI] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES