Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1986 Jan;70(1):55–59. doi: 10.1136/bjo.70.1.55

Photokeratoscopy in fitting contact lens after penetrating keratoplasty.

R Manabe, M Matsuda, T Suda
PMCID: PMC1040904  PMID: 3511959

Abstract

The formula based on keratometric readings which is generally used is unsatisfactory for fitting contact lenses after penetrating keratoplasty, possibly owing to lack of information on the peripheral corneal toricity. In these studies a photokeratoscope was used to examine the entire graft topography. In all cases the corneal configuration became more normal after suture removal, but a considerable toricity still remained, especially near the graft-host junction. One month after removal of sutures spherical hard contact lenses (polymethylmethacrylate, PMMA) were fitted to 30 patients in accordance with data obtained by computerised analysis of the photokeratograms. Of the 30 patients (contact lens wearers) 27 (90%) obtained a stable vision of better than 20/30 for eight hours daily, and 24 (80%) achieved a stable vision of 20/20 for their full waking hours. After one year the contact lens wearers showed a significant decrease in the extent of astigmatism when compared with the non-contact-lens wearers (10 patients). These results suggest that the photokeratoscope can be more useful than ordinary keratometers in fitting contact lenses after keratoplasty, and that hard contact lenses have moulding effects on the graft topography.

Full text

PDF
55

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Daniel R. Fitting contact lenses after keratoplasty. Br J Ophthalmol. 1976 Apr;60(4):263–265. doi: 10.1136/bjo.60.4.263. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Krachmer J. H., Fenzl R. E. Surgical correction of high postkeratoplasty astigmatism. Relaxing incisions vs wedge resection. Arch Ophthalmol. 1980 Aug;98(8):1400–1402. doi: 10.1001/archopht.1980.01020040252007. [DOI] [PubMed] [Google Scholar]
  3. Matsuda M., Suda T., Manabe R. Long-term observations of the graft endothelium with different postoperative courses. Jpn J Ophthalmol. 1983;27(4):556–566. [PubMed] [Google Scholar]
  4. Matsuda M., Suda T., Manabe R. Quantitative analysis of endothelial mosaic pattern changes in anterior keratoconus. Am J Ophthalmol. 1984 Jul 15;98(1):43–49. doi: 10.1016/0002-9394(84)90187-9. [DOI] [PubMed] [Google Scholar]
  5. Matsuda M., Suda T., Manabe R. Serial alterations in endothelial cell shape and pattern after intraocular surgery. Am J Ophthalmol. 1984 Sep 15;98(3):313–319. doi: 10.1016/0002-9394(84)90321-0. [DOI] [PubMed] [Google Scholar]
  6. Ruben M., Colebrook E. Keratoconus keratoplasty curvatures and contact lens wear. Br J Ophthalmol. 1979 Apr;63(4):268–273. doi: 10.1136/bjo.63.4.268. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Troutman R. C. Astigmatic considerations in corneal graft. Ophthalmic Surg. 1979 May;10(5):21–26. [PubMed] [Google Scholar]
  8. Troutman R. C., Gaster R. N. Surgical advances and results of keratoconus. Am J Ophthalmol. 1980 Aug;90(2):131–136. doi: 10.1016/s0002-9394(14)74843-3. [DOI] [PubMed] [Google Scholar]
  9. Troutman R. C., Kelly S., Kaye D., Clahane A. C. The use and preliminary results of the Troutman surgical keratometer in cataract and corneal surgery. Trans Sect Ophthalmol Am Acad Ophthalmol Otolaryngol. 1977 Mar-Apr;83(2):232–238. [PubMed] [Google Scholar]
  10. Troutman R. C., Meltzer M. Astigmatism and myopia in keratoconus. Trans Am Ophthalmol Soc. 1972;70:265–277. [PMC free article] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES