Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 1988 Mar;72(3):231–235. doi: 10.1136/bjo.72.3.231

Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL.

T Olsen 1
PMCID: PMC1041415  PMID: 3355811

Abstract

The pre- and postoperative refraction results are reported in 99 patients receiving an anterior chamber lens of standard 19.0 D power after intracapsular cataract extraction. The mean refraction after the operation was -0.76 D, SD 2.13. Apart from eight patients with suspected lenticular myopia, 5% of the patients ended up with a refraction that differed more than +/- 5D from the preoperative value. This variation was due to variation in the power of the biological lens removed at surgery, the mean value of which was 22.8 D, SD 3.3. As a measure of the aniseikonia induced at surgery, the ocular magnification was calculated to increase 2.7%, SD 4.2%, as compared with the preoperative value. The variation should be considered in the discussion of whether a preoperative biometry and calculation of appropriate IOL power are recommended or not.

Full text

PDF
231

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Binkhorst C. D., Leonard P. A. Results in 208 iris-clip pseudophakos implantations. Am J Ophthalmol. 1967 Nov;64(5):947–956. doi: 10.1016/0002-9394(67)92241-6. [DOI] [PubMed] [Google Scholar]
  2. Binkhorst R. D. Pitfalls in the determination of intraocular lens power without ultrasound. Ophthalmic Surg. 1976 Fall;7(3):69–82. [PubMed] [Google Scholar]
  3. Binkhorst R. D. The accuracy of ultrasonic measurement of the axial length of the eye. Ophthalmic Surg. 1981 May;12(5):363–365. [PubMed] [Google Scholar]
  4. Clevenger C. E. Clinical prediction versus ultrasound measurement of IOL power. J Am Intraocul Implant Soc. 1978 Oct;4(4):222–224. doi: 10.1016/s0146-2776(78)80100-1. [DOI] [PubMed] [Google Scholar]
  5. Colenbrander M. C. Calculation of the power of an iris clip lens for distant vision. Br J Ophthalmol. 1973 Oct;57(10):735–740. doi: 10.1136/bjo.57.10.735. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Hillman J. S., Hawkswell A. The control of aniseikonia after intraocular lens implantation. Trans Ophthalmol Soc U K. 1985;104(Pt 5):582–585. [PubMed] [Google Scholar]
  7. Hillman J. S. Intraocular lens power calculation--the selection of formula. Trans Ophthalmol Soc U K. 1985;104(Pt 7):693–698. [PubMed] [Google Scholar]
  8. Kraff M. C., Sanders D. R., Lieberman H. L. Determination of intraocular lens power: a comparison with and without ultrasound. Ophthalmic Surg. 1978 Feb;9(1):81–84. [PubMed] [Google Scholar]
  9. Nolan J., Hawkswell A. Clinical aspects of unilateral aphakia. Trans Ophthalmol Soc U K. 1974 Jul;94(2):480–486. [PubMed] [Google Scholar]
  10. Olsen T. On the calculation of power from curvature of the cornea. Br J Ophthalmol. 1986 Feb;70(2):152–154. doi: 10.1136/bjo.70.2.152. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Olsen T. Theoretical approach to intraocular lens calculation using Gaussian optics. J Cataract Refract Surg. 1987 Mar;13(2):141–145. doi: 10.1016/s0886-3350(87)80128-1. [DOI] [PubMed] [Google Scholar]
  12. Olsen T. Theoretical, computer-assisted prediction versus SRK prediction of postoperative refraction after intraocular lens implantation. J Cataract Refract Surg. 1987 Mar;13(2):146–150. doi: 10.1016/s0886-3350(87)80129-3. [DOI] [PubMed] [Google Scholar]
  13. Ossoinig K. C. Standardized echography: basic principles, clinical applications, and results. Int Ophthalmol Clin. 1979 Winter;19(4):127–210. [PubMed] [Google Scholar]
  14. Retzlaff J. A new intraocular lens calculation formula. J Am Intraocul Implant Soc. 1980 Apr;6(2):148–152. doi: 10.1016/s0146-2776(80)80008-5. [DOI] [PubMed] [Google Scholar]
  15. Sanders D. R., Kraff M. C. Improvement of intraocular lens power calculation using empirical data. J Am Intraocul Implant Soc. 1980 Jul;6(3):263–267. doi: 10.1016/s0146-2776(80)80075-9. [DOI] [PubMed] [Google Scholar]
  16. TROUTMAN R. C. ARTIPHAKIA AND ANISEIKONIA. Am J Ophthalmol. 1963 Oct;56:602–639. doi: 10.1016/0002-9394(63)90010-2. [DOI] [PubMed] [Google Scholar]
  17. Thompson S. M., Mohan-Roberts V. A comparison of postoperative refractive results with and without intraocular lens power calculation. Br J Ophthalmol. 1986 Jan;70(1):22–25. doi: 10.1136/bjo.70.1.22. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from The British Journal of Ophthalmology are provided here courtesy of BMJ Publishing Group

RESOURCES