Abstract
To assess the accuracy of routine preoperative biometry we reviewed all cases of extracapsular cataract extraction with posterior chamber implant performed at Queen Alexandra Hospital in 1985. Of 471 eyes included in the survey 67.9% were within 1.0 D of the expected refraction and 90.7% within 2.0 D. Factors influencing accuracy are discussed. The necessity of routine preoperative biometry is emphasised.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Binkhorst R. D. Pitfalls in the determination of intraocular lens power without ultrasound. Ophthalmic Surg. 1976 Fall;7(3):69–82. [PubMed] [Google Scholar]
- Hillman J. S. Intraocular lens power calculation for planned ametropia: a clinical study. Br J Ophthalmol. 1983 Apr;67(4):255–258. doi: 10.1136/bjo.67.4.255. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hillman J. S. The computer calculation of intraocular lens power. A clinical study. Trans Ophthalmol Soc U K. 1980 Apr;100(Pt 1):222–228. [PubMed] [Google Scholar]
- Hillman J. S. The selection of intraocular lens power by calculation and by reference to the refraction--a clinical study. Trans Ophthalmol Soc U K. 1982;102(Pt 4):495–497. [PubMed] [Google Scholar]
- Hoffer K. J. Accuracy of ultrasound intraocular lens calculation. Arch Ophthalmol. 1981 Oct;99(10):1819–1823. doi: 10.1001/archopht.1981.03930020693014. [DOI] [PubMed] [Google Scholar]
- Hoffer K. J. Biometry of 7,500 cataractous eyes. Am J Ophthalmol. 1980 Sep;90(3):360–368. doi: 10.1016/s0002-9394(14)74917-7. [DOI] [PubMed] [Google Scholar]
- Johns G. E. Clinical evaluation of the DBR A-scan unit. J Am Intraocul Implant Soc. 1979 Jul;5(3):213–216. doi: 10.1016/s0146-2776(79)80113-5. [DOI] [PubMed] [Google Scholar]
- Kraff M. C., Sanders D. R., Lieberman H. L. Determination of intraocular lens power: a comparison with and without ultrasound. Ophthalmic Surg. 1978 Feb;9(1):81–84. [PubMed] [Google Scholar]
- Maloney W. F., Kratz R. P., Mazzocco T. R., Davidson B. Posterior chamber intraocular lens power calculation in 441 cases. J Am Intraocul Implant Soc. 1979 Oct;5(4):349–349. doi: 10.1016/s0146-2776(79)80102-0. [DOI] [PubMed] [Google Scholar]
- Mathers W. D., Grutzmacher R. D. Lens implant calculations using an average of several formulas. CLAO J. 1986 Oct-Dec;12(4):216–218. [PubMed] [Google Scholar]
- Olson R. J. Intraocular lens optical quality: update 1979. J Am Intraocul Implant Soc. 1980 Jan;6(1):16–17. doi: 10.1016/s0146-2776(80)80099-1. [DOI] [PubMed] [Google Scholar]
- Olson R. J., Kolodner H., Kaufman H. E. The optical quality of currently manufactured intraocular lenses. Am J Ophthalmol. 1979 Sep;88(3 Pt 2):548–555. doi: 10.1016/0002-9394(79)90513-0. [DOI] [PubMed] [Google Scholar]
- Percival P. Lens power calculation--is it necessary? Trans Ophthalmol Soc U K. 1983;103(Pt 5):577–579. [PubMed] [Google Scholar]
- Retzlaff J. Posterior chamber implant power calculation: regression formulas. J Am Intraocul Implant Soc. 1980 Jul;6(3):268–270. doi: 10.1016/s0146-2776(80)80076-0. [DOI] [PubMed] [Google Scholar]
- Roper-Hall M. J. Control of astigmatism after surgery and trauma. Br J Ophthalmol. 1982 Sep;66(9):556–559. doi: 10.1136/bjo.66.9.556. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sanders D. R., Kraff M. C. Improvement of intraocular lens power calculation using empirical data. J Am Intraocul Implant Soc. 1980 Jul;6(3):263–267. doi: 10.1016/s0146-2776(80)80075-9. [DOI] [PubMed] [Google Scholar]
- Shammas H. J. A comparison of immersion and contact techniques for axial length measurement. J Am Intraocul Implant Soc. 1984 Fall;10(4):444–447. doi: 10.1016/s0146-2776(84)80044-0. [DOI] [PubMed] [Google Scholar]
- Shammas H. J. The fudged formula for intraocular lens power calculations. J Am Intraocul Implant Soc. 1982 Fall;8(4):350–352. doi: 10.1016/s0146-2776(82)80028-1. [DOI] [PubMed] [Google Scholar]
- Summers C. G., Lindstrom R. L. Secondary IOL power calculations: a comparison of regression formula and refraction method in accurate prediction of emmetropia. J Am Intraocul Implant Soc. 1984 Fall;10(4):448–451. doi: 10.1016/s0146-2776(84)80045-2. [DOI] [PubMed] [Google Scholar]
- Thompson J. T., Maumenee A. E., Baker C. C. A new posterior chamber intraocular lens formula for axial myopes. Ophthalmology. 1984 May;91(5):484–488. doi: 10.1016/s0161-6420(84)34263-4. [DOI] [PubMed] [Google Scholar]
- Thompson S. M., Mohan-Roberts V. A comparison of postoperative refractive results with and without intraocular lens power calculation. Br J Ophthalmol. 1986 Jan;70(1):22–25. doi: 10.1136/bjo.70.1.22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tutton M. K. Intraocular lens power calculation using the SRK formula: a clinical study. Trans Ophthalmol Soc U K. 1985;104(Pt 6):675–680. [PubMed] [Google Scholar]
