Abstract
The predictability of a theoretical, computer-assisted IOL calculation method and of the Sanders-Retzlaff-Kraff (SRK) method was evaluated from pre- and postoperative biometry in 110 cataractous patients subjected to a routine IOL calculation. With the theoretical method and the preoperative data the refraction was on the average 0.72 D (SD 0.78) more myopic than expected, an error which could be corrected for by (1) substituting the assumed postoperative chamber depth by the actual mean value and (2) adding 0.16 mm to the preoperative axial length. With the postoperative data the error was 0.05 D (SD 0.78) (p greater than 0.05). By the SRK method the refraction was 0.15 D (SD 0.71) and 0.37 D (SD 0.69) more hyperopic than expected with the pre- and the postoperative data respectively. These offset errors could be corrected for in either case by adjusting the assumed A constant in the SRK formula. With appropriate empirical corrections for offset errors the theoretical and the SRK method were similar in accuracy, that is, about 82% of the predictions within +/- 1 D, 99% within +/- 2 D, and 100% within +/- 3 D error. The variation in postoperative refraction after computerised IOL calculation was about one-third of the variation previously seen after implantation of standard power IOL.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Binkhorst C. D. Dioptrienzahl künstlicher Augenlinsen. Klin Monbl Augenheilkd. 1973 Mar;162(3):354–361. [PubMed] [Google Scholar]
- Colenbrander M. C. Calculation of the power of an iris clip lens for distant vision. Br J Ophthalmol. 1973 Oct;57(10):735–740. doi: 10.1136/bjo.57.10.735. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Donzis P. B., Kastl P. R., Gordon R. A. An intraocular lens formula for short, normal and long eyes. CLAO J. 1985 Apr-Jun;11(2):95–98. [PubMed] [Google Scholar]
- Freudiger H., Artaria L., Niesel P. Influence of intraocular lenses on ultrasound axial length measurement: in vitro and in vivo studies. J Am Intraocul Implant Soc. 1984 Winter;10(1):29–34. doi: 10.1016/s0146-2776(84)80073-7. [DOI] [PubMed] [Google Scholar]
- Fyodorov S. N., Galin M. A., Linksz A. Calculation of the optical power of intraocular lenses. Invest Ophthalmol. 1975 Aug;14(8):625–628. [PubMed] [Google Scholar]
- Hillman J. S. Intraocular lens power calculation--the selection of formula. Trans Ophthalmol Soc U K. 1985;104(Pt 7):693–698. [PubMed] [Google Scholar]
- Holladay J. T., Prager T. C., Ruiz R. S., Lewis J. W., Rosenthal H. Improving the predictability of intraocular lens power calculations. Arch Ophthalmol. 1986 Apr;104(4):539–541. doi: 10.1001/archopht.1986.01050160095020. [DOI] [PubMed] [Google Scholar]
- Olsen T. Prediction of intraocular lens position after cataract extraction. J Cataract Refract Surg. 1986 Jul;12(4):376–379. doi: 10.1016/s0886-3350(86)80099-2. [DOI] [PubMed] [Google Scholar]
- Olsen T. Theoretical approach to intraocular lens calculation using Gaussian optics. J Cataract Refract Surg. 1987 Mar;13(2):141–145. doi: 10.1016/s0886-3350(87)80128-1. [DOI] [PubMed] [Google Scholar]
- Olsen T. Theoretical vs empirical prediction of aphakic refraction. Arch Ophthalmol. 1987 Aug;105(8):1042–1045. doi: 10.1001/archopht.1987.01060080044025. [DOI] [PubMed] [Google Scholar]
- Olsen T. Theoretical, computer-assisted prediction versus SRK prediction of postoperative refraction after intraocular lens implantation. J Cataract Refract Surg. 1987 Mar;13(2):146–150. doi: 10.1016/s0886-3350(87)80129-3. [DOI] [PubMed] [Google Scholar]
- Olson R. J. Intraocular lens power calculations. An extra edge or expensive waste? Arch Ophthalmol. 1987 Aug;105(8):1035–1036. doi: 10.1001/archopht.1987.01060080037022. [DOI] [PubMed] [Google Scholar]
- Percival P. Lens power calculation--is it necessary? Trans Ophthalmol Soc U K. 1983;103(Pt 5):577–579. [PubMed] [Google Scholar]
- Retzlaff J. A new intraocular lens calculation formula. J Am Intraocul Implant Soc. 1980 Apr;6(2):148–152. doi: 10.1016/s0146-2776(80)80008-5. [DOI] [PubMed] [Google Scholar]
- Richards S. C., Olson R. J., Richards W. L., Brodstein R. S., Hale P. N. Clinical evaluation of six intraocular lens calculation formulas. J Am Intraocul Implant Soc. 1985 Mar;11(2):153–158. doi: 10.1016/s0146-2776(85)80010-0. [DOI] [PubMed] [Google Scholar]
- Sanders D. R., Kraff M. C. Improvement of intraocular lens power calculation using empirical data. J Am Intraocul Implant Soc. 1980 Jul;6(3):263–267. doi: 10.1016/s0146-2776(80)80075-9. [DOI] [PubMed] [Google Scholar]
- Sanders D., Retzlaff J., Kraff M., Kratz R., Gills J., Levine R., Colvard M., Weisel J., Loyd T. Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas. J Am Intraocul Implant Soc. 1981 Fall;7(4):337–340. doi: 10.1016/s0146-2776(81)80031-6. [DOI] [PubMed] [Google Scholar]
- Shammas H. J. A comparison of immersion and contact techniques for axial length measurement. J Am Intraocul Implant Soc. 1984 Fall;10(4):444–447. doi: 10.1016/s0146-2776(84)80044-0. [DOI] [PubMed] [Google Scholar]
- Singh K., Sommer A., Jensen A. D., Payne J. W. Intraocular lens power calculations. A practical evaluation in normal subjects at the Wilmer Institute. Arch Ophthalmol. 1987 Aug;105(8):1046–1050. doi: 10.1001/archopht.1987.01060080048026. [DOI] [PubMed] [Google Scholar]
- Thompson J. T., Maumenee A. E., Baker C. C. A new posterior chamber intraocular lens formula for axial myopes. Ophthalmology. 1984 May;91(5):484–488. doi: 10.1016/s0161-6420(84)34263-4. [DOI] [PubMed] [Google Scholar]
- Thompson S. M., Mohan-Roberts V. A comparison of postoperative refractive results with and without intraocular lens power calculation. Br J Ophthalmol. 1986 Jan;70(1):22–25. doi: 10.1136/bjo.70.1.22. [DOI] [PMC free article] [PubMed] [Google Scholar]
