Abstract
An investigation into the causes of non-compliance by patients using eyedrops has been undertaken by questionnaire, ability tests, and by tests on eyedrop bottles. The results indicate a high prevalence of non-compliance, compounded by an inability adequately to instill a drop into the eye. About half the patients had difficulty aiming the drop, and other problems including squeezing the bottle, blinking, and seeing the tip of the bottle. Ability tests included a measurement of the grip strength of patients to complement measurement of the force required to expel a drop from a bottle. Some patients, particularly those with arthritis, could not generate enough force to squeeze a bottle. These same patients also had difficulty with the other movements required to administer drops. While some attempts have been made to produce devices to assist with eyedrops which can improve the aim of the patient, none give assistance in expelling a drop. An additional problem found was the reluctance of patients to admit to medical staff that they experienced any difficulty with their drops.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bloch S., Rosenthal A. R., Friedman L., Caldarolla P. Patient compliance in glaucoma. Br J Ophthalmol. 1977 Aug;61(8):531–534. doi: 10.1136/bjo.61.8.531. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brown M. M., Brown G. C., Spaeth G. L. Improper topical self-administration of ocular medication among patients with glaucoma. Can J Ophthalmol. 1984 Feb;19(1):2–5. [PubMed] [Google Scholar]
- Donnelly D. Instilling eyedrops: difficulties experienced by patients following cataract surgery. J Adv Nurs. 1987 Mar;12(2):235–243. doi: 10.1111/j.1365-2648.1987.tb01327.x. [DOI] [PubMed] [Google Scholar]
- Kass M. A., Hodapp E., Gordon M., Kolker A. E., Goldberg I. Part I. Patient administration of eyedrops: interview. Ann Ophthalmol. 1982 Aug;14(8):775–779. [PubMed] [Google Scholar]
- Kass M. A., Hodapp E., Gordon M., Kolker A. E., Goldberg I. Patient administration of eyedrops: observation. Part II. Ann Ophthalmol. 1982 Sep;14(9):889–893. [PubMed] [Google Scholar]
- Kass M. A., Meltzer D. W., Gordon M., Cooper D., Goldberg J. Compliance with topical pilocarpine treatment. Am J Ophthalmol. 1986 May 15;101(5):515–523. doi: 10.1016/0002-9394(86)90939-6. [DOI] [PubMed] [Google Scholar]
- Law S. Development and utilization of the eyedropper adaptation device: an example of interdisciplinary cooperation. Home Healthc Nurse. 1987 Jul-Aug;5(4):50–51. doi: 10.1097/00004045-198707000-00009. [DOI] [PubMed] [Google Scholar]
- Lederer C. M., Jr, Harold R. E. Drop size of commercial glaucoma medications. Am J Ophthalmol. 1986 Jun 15;101(6):691–694. doi: 10.1016/0002-9394(86)90771-3. [DOI] [PubMed] [Google Scholar]
- Letocha C. E. Methods for self-administration of eyedrops. Ann Ophthalmol. 1985 Dec;17(12):768–769. [PubMed] [Google Scholar]
- MacKean J. M., Elkington A. R. Compliance with treatment of patients with chronic open-angle glaucoma. Br J Ophthalmol. 1983 Jan;67(1):46–49. doi: 10.1136/bjo.67.1.46. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mings D. E. Drop aid. Trans Am Acad Ophthalmol Otolaryngol. 1967 Mar-Apr;71(2):368–368. [PubMed] [Google Scholar]
- Norell S. E., Granström P. A. Self-medication with pilocarpine among outpatients in a glaucoma clinic. Br J Ophthalmol. 1980 Feb;64(2):137–141. doi: 10.1136/bjo.64.2.137. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sheldon G. M. Self-administration of eyedrops. Ophthalmic Surg. 1987 May;18(5):393–394. [PubMed] [Google Scholar]
- Van Buskirk E. M. The compliance factor. Am J Ophthalmol. 1986 May 15;101(5):609–610. doi: 10.1016/0002-9394(86)90954-2. [DOI] [PubMed] [Google Scholar]
- Zimmerman T. J., Zalta A. H. Facilitating patient compliance in glaucoma therapy. Surv Ophthalmol. 1983 Dec;28 (Suppl):252–258. doi: 10.1016/0039-6257(83)90142-x. [DOI] [PubMed] [Google Scholar]