Abstract
A postural study was conducted in three separate groups of subjects. The first group comprised 20 women volunteers with an average age of 20-75 years. In this group, the study was conducted by the pneumatonograph only. Mean pressure recorded was 15-65 +/- 0-25 mmHg and there was an average rise of 1-4 mmHg in supine posture. Groups 2 and 3 comprised 151 non-glaucomatous and 108 glaucomatous eyes respectively in the age range of 30 to 85 years. In these two groups, the study was conducted using the PTG and the Mackay-Marg tonometer. Clinical evaluation of the Mackay-Marg with the PTG gave significant correlation, with mean Mackay-Marg readings being 1-13 mmHg higher. The intraocular pressure when changing from seated to the supine position increased on average by 2-71 and 4-04 mmHg, respectively in Groups 2 and 3 and by 2-51 and 3-72 mmHg by Vackay-Marg, suggesting a higher change in glaucomatous subjects. Pressure on resumption of sitting was found to be lower than the initial pressure. Postural change also showed some direct relationship with age in non-glaucomatous subjects.
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- ARMALY M. F., SALAMOUN S. G. SCHIOTZ AND APPLANATION TONOMETRY. Arch Ophthalmol. 1963 Nov;70:603–609. doi: 10.1001/archopht.1963.00960050605005. [DOI] [PubMed] [Google Scholar]
- Anderson D. R., Grant W. M. The influence of position on intraocular pressure. Invest Ophthalmol. 1973 Mar;12(3):204–212. [PubMed] [Google Scholar]
- Best M., Rogers R. Techniques of ocular pulse analysis in carotid stenosis. Arch Ophthalmol. 1974 Jul;92(1):54–58. doi: 10.1001/archopht.1974.01010010058014. [DOI] [PubMed] [Google Scholar]
- GALIN M. A., McIVOR J. W., MAGRUDER G. B. Influence of position on intraocular pressure. Am J Ophthalmol. 1963 Apr;55:720–723. [PubMed] [Google Scholar]
- Irvine A. R., Kaufman H. E. Intraolar pressure following penetrating keratoplasty. Am J Ophthalmol. 1969 Nov;68(5):835–844. doi: 10.1016/0002-9394(69)94577-2. [DOI] [PubMed] [Google Scholar]
- Jain M. R., Marmion V. J. A clinical evaluation of the applanation pneumatonograph. Br J Ophthalmol. 1976 Feb;60(2):107–110. doi: 10.1136/bjo.60.2.107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kaufman H. E., Wind C. A., Waltman S. R. Validity of Mackay-Marg electronic applanation tonometer in patients with scarred irregular corneas. Am J Ophthalmol. 1970 Jun;69(6):1003–1007. doi: 10.1016/0002-9394(70)91047-0. [DOI] [PubMed] [Google Scholar]
- Krieglstein G., Langham M. E. Influence of body position on the intraocular pressure of normal and glaucomatous eyes. Ophthalmologica. 1975;171(2):132–145. doi: 10.1159/000307479. [DOI] [PubMed] [Google Scholar]
- Langham M. E., McCarthy E. A rapid pneumatic applanation tonometer. Comparative findings and evaluation. Arch Ophthalmol. 1968 Apr;79(4):389–399. doi: 10.1001/archopht.1968.03850040391006. [DOI] [PubMed] [Google Scholar]
- Quigley H. A., Langham M. E. Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer. Am J Ophthalmol. 1975 Aug;80(2):266–273. doi: 10.1016/0002-9394(75)90144-0. [DOI] [PubMed] [Google Scholar]
- Tarkkanen A., Leikola J. Postural variations of the intraocular pressure as measured with the Mackay-Marg tonometer. Acta Ophthalmol (Copenh) 1967;45(4):569–575. doi: 10.1111/j.1755-3768.1967.tb06523.x. [DOI] [PubMed] [Google Scholar]
- Tierney J. P., Rubin M. L. A clinical evaluation of the electronic applanation tonometer. Am J Ophthalmol. 1966 Aug;62(2):263–272. doi: 10.1016/0002-9394(66)91482-6. [DOI] [PubMed] [Google Scholar]