Skip to main content
CoDAS logoLink to CoDAS
. 2023 Aug 4;35(4):e20210273. doi: 10.1590/2317-1782/20232021273en
View full-text in Portuguese

Occurrence of changes in the auditory evoked potentials of smokers: systematic review of the literature

Dayane Stephanie Potgurski 1, Georgea Espindola Ribeiro 2, Daniela Polo Camargo da Silva 1,
PMCID: PMC10446745  PMID: 37556701

ABSTRACT

Purpose

To verify the occurrence of abnormal auditory evoked potentials (AEP) tests in adult smokers.

Research strategies

Systematic review of the literature according to the PRISMA guidelines, to answer the question: “Are there any changes in the AEP results in adult smokers?”, PECOS strategy. Research carried out on PubMed, Embase, CINAHL, LIVIVO, Scopus, Web of Science, LILACS and Scielo databases. Additional search of gray literature: Google Scholar and ProQuest hand searching of reference lists of the included studies.

Selection criteria

Cross-sectional studies were selected, without restriction on the year of publication and language.

Data analysis

First, the titles and abstracts of all the studies were analyzed, followed by the full reading of the eligible studies.

Results

898 articles were collected, after the duplicate studies were removed and after blind analysis by three researchers, 8 studies of the observational type were selected. Most studies have found an association between active smoking and changes in electrophysiological tests.

Conclusion

Normal hearing adult smokers present alterations in short and long AEP. In the auditory brainstem response, the main altered components were the increase in waves latencies of I and III and in the interpeaks I - III and III - V, as well as a decrease in the amplitude of the waves. In Mismatch Negativity, there was a significant increase in wave amplitude and latency. In the long latency potential, P300, there was an increase in latencies and decreased amplitudes in the components N1 (in Fz) and P3.

Keywords: Smokers, Electrophysiology, Hearing, Cochlear Nerve, Auditory Evoked Potentials

INTRODUCTION

Tobacco consumption is considered one of the major risk factors that cause morbidity and mortality worldwide and it is known that its consumption is main nicotine release way, which is highly absorbed into the bloodstream and can compromise different structures of the organism, producing several harmful effects, such as heart disease, stroke, chronic obstructive pulmonary disease, as well as cancer and cognitive impairment, among others(1,2).

Tobacco also causes decreased cell oxygenation, vascular blockage, changes in blood viscosity, formation of atherosclerotic plaque, and decreased oxygen supply, which can lead to impaired blood supply, including to the auditory pathways(1-3).

Therefore, the auditory system can be exposed to harmful influences from this adverse event and, when it comes to ototoxicity, its effects can be transient or permanent, depending on which structures were affected or the characteristics of the exposure(4). Also, as any type of hearing impairment can lead to a worsening of the individual's quality of life, many authors have explored the association between tobacco use and its effect on hearing over the years(5).

A recent 8-year cohort study verified the prospective association of tobacco use, intensity, and smoking cessation with the risk of hearing loss, which included 50,195 participants, aged between 20 and 64 years and without hearing loss at the beginning of the study. Pure-tone threshold audiometry was performed annually, and during monitoring, 3,532 individuals developed high-frequency hearing loss and 1,575 developed low-frequency hearing loss. The conclusion was that smoking is associated with an increased risk of hearing loss, especially at high frequencies, in a dose-response manner. The excessive risk of hearing loss associated with smoking disappeared in a relatively short period after smoking cessation(5).

In addition to the occurrence of sensorineural hearing loss at high frequencies, a study also observed the presence of a high number of smokers with tube dysfunction, which increases the incidence of middle ear diseases, as it brings nonspecific symptoms characterized by ear fullness and difficulty equalizing the middle ear(6).

Furthermore, nicotine can be transported to receptors in the central nervous system and may involve both peripheral and central auditory structures(1,7). It is also known that the degeneration of the function of the nervous system happens mostly in a rostrocaudal manner, that is, it starts with the cortex, passing through the subcortical regions until reaching the brainstem(8). Thus, the investigation of the nicotine effect on the central auditory nervous system (CANS) has also been investigated by means of the auditory evoked potential (AEP).

The AEP is a set of methods that evaluate the electrobiological activity along the auditory system, from the inner ear to the cerebral cortex. Thus, the application of these tests allows the investigation of hearing neurophysiological conditions(9).

The AEPs can be divided into three types. The brainstem auditory evoked potential (BAEP), considered a short-latency potential, stands out; it appears in an interval of approximately 10 ms after stimulation, which allows the neurophysiological analysis of the auditory pathway, from the inner ear to the high brainstem(10). The middle-latency auditory evoked potential, which appears approximately 80 ms after stimulation, originates in the primary auditory cortex - more specifically from the nuclei and auditory pathways to the level of the thalamus-cortical region and primary auditory cortex(11); finally, the long-latency auditory evoked potential, which appears around 100 to 700 ms after stimulation, reflecting activities of the auditory pathway in the regions of the thalamus and auditory cortex, providing information about the CANS functioning(12).

Thus, sensorineural hearing loss at high frequencies of cochlear origin compromises the morphology of AEP waves, as well as retrocochlear disorders. In this sense, studies indicate that there are alterations in the parameters of AEP test records in smokers when compared to non-smokers, such as increased latencies and decreased response amplitudes, even in the absence of increased auditory thresholds, and these findings may somehow influence the correct processing of acoustic information(7,13,14).

Several anatomical sites, responsible for producing the neuroelectric activity of the auditory pathway in response to acoustic stimulation, may behave differently in smokers, which makes it necessary to assess what evidence is available in the literature that proves the existence or not of that association.

In view of the above, studies have pointed to the need to carry out additional tests for basic audiological assessment in order to investigate the extent of the injury caused by constant tobacco exposure, helping in a better understanding of the alterations found, besides detailing the types of alterations that smoking causes to the CANS(2,7,13,14).

Thus, the AEPs analysis proves to be useful in the differential diagnosis of sensorineural hearing loss, bringing important pieces of information that can indicate objectively if the lesion is located at the cochlear and/or retrocochlear level, as well as showing early changes in the sites that generate the neural response, before changes are detected in the basic audiological assessment(2,7,13,14).

PURPOSE

This study aimed to verify the occurrence of abnormal auditory evoked potentials (AEP) tests in adult smokers with normal hearing, through a systematic review of the literature.

Research strategy

This systematic review followed the recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-analyses - PRISMA(15).

Observational studies on adult smokers (aged 18 years and under 60 years) were considered eligible for this systematic review, which aimed to assess the integrity of the auditory pathway by means of the AEP test. There was no restriction on the study publication date. The following studies were excluded: (1) review articles, letters, case studies, and event abstracts; (2) studies on smokers associated with other diseases; (3) studies that included individuals younger than 18 years old or older than 60 years old; (4) studies carried out with smokers with hearing alterations prior to addiction; (5) studies without a control group; (6) studies without the full version available.

The following guiding question was used to conduct the study: “Are there any changes in the AEP results in adult smokers?” The PECOS approach(16) (Patient, Exposure, Comparison, Outcomes, Studies) was used to formulate the guiding question. Thus, in this literature review, PECOS stands for P - population (adults), E - exposure to tobacco; C - tobacco non-exposed adults; O - any change in auditory evoked potential tests, and S - design of included, observational cross-sectional studies (S).

Individual electronic search strategies were developed, using the combination of the following descriptors in Portuguese and English, respectively: “Fumantes,” “Potenciais Evocados Auditivos,” “Eletrofisiologia,”, “Nervo Coclear,” “Smokers”, “Auditory Evoked Potentials,” “Electrophysiology,” “Cochlear Nerve.” In order to encompass certain thematic axes, the Boolean operators “OR” and “AND” were used, according to MESH/DECS, for each of the following databases: PubMed, Embase, CINAHL, LIVIVO, Scopus, Web of Science, LILACS, and Scielo. Additional search of gray literature was made by accessing Google Scholar and ProQuest. Moreover, hand searching of reference lists of the included studies was conducted, as recommended by Greenhalgh and Peacock (2005)(17). EndNote Web®, reference manager software, was used to collect references and delete duplicates. The collection date on the databases was held on March 24, 2021. Studies that answered the research question were selected, without restriction on publication date and language.

Selection criteria

The selection stage had two phases. In phase one, the titles and abstracts of all identified database citations were screened by two reviewers independently. Studies that did not meet the eligibility criteria were excluded. In phase two, the same two reviewers applied the eligibility criteria to the full text of the studies. A third reviewer was consulted in case of disagreement that was not resolved by a consensus discussion between the two reviewers.

Data analysis

Two authors collected the necessary information from the selected studies. A third author confirmed the veracity of the information collected by checking the full text of the articles against the information selected by the first two authors. Any controversies in this process were discussed and a consensus was established. The data extracted from the studies were: characteristics of the studies (authors, year of publication, country, type of study), characteristics of the population (sample size, age range of the group studied), characteristic of exposure (smoking characterization), and characteristics of the outcome (type of alteration found in the retrocochlear auditory pathway, type of AEP used, and main findings presented by the studies).

The risk of bias assessment of the selected studies was evaluated using the JBI Critical Appraisal Checklist for Studies Reporting Prevalence Data(18). The first and second authors performed this assessment independently. Any disagreements that arose were resolved with the third author’s help.

For each domain of the tool, one of the following responses was assigned: “Yes,” “No,” “Unclear” or “Not Applicable”(13). Regarding the percentage of “Yes” of each analyzed study, classification was as follows: high risk of bias (> 49%), moderate high risk of bias (50 to 69%), or low high risk of bias (> 70%).

RESULTS

The first phase of the selection process resulted in 898 citations on electronic databases. After removing duplicates, a total of 537 were evaluated. After reading the titles and abstracts, 47 references were selected to be screened by full-text reading, which resulted in the inclusion of eight studies for qualitative and quantitative evaluation. A new article was added after hand searching of the reference list of articles included. Both selection and exclusion processes are shown in Figure 1.

Figure 1. Flowchart of literature search and selection criteria.

Figure 1

Source: Adapted from PRISMA

The articles included had been published in different scientific journals (total of eight). The number of smokers included in the studies ranged from 1019 to 137(19). Regarding the country of origin of the studies, one was from Brazil(14), two were from Turkey(20,21), two were from India(7,22), two were from Egypt(13,23), and one from Germany(19). Due to the nature of the guiding question, all included studies used convenience samples. A summary of the characteristics of the eight included studies can be found in Chart 1. Regarding the test performed, three performed BAEP(7,14,22), four performed P300(19-21,23), and one performed Mismatch Negativity (MMN) and P300(13).

Chart 1. Summary of studies included.

Author Country Age (mean in years) Sex (%) Sample size Test used Audiological outcomes Conclusions
Aşçioglu et al.(20) Turkey 23 ± 2.3 NS 10 chronic smokers P300 There were no significant differences between mean latency or amplitude values between groups (N1, P2, N2 and P300). Chronic smoking did not interfere with the P300 response.
10 non-smokers
Dixit et al.(7) India Smokers 28.7 ± 2.7 100% M 30 chronic smokers BAEP Significant increase in the latencies of waves I and III and in the interpeak I-III, as well as a decrease in wave amplitudes in smokers. Chronic smoking affects the auditory pathway.
Non-smokers: 26.9 ± 1.8 30 non-smokers
El-Shenawy et al.(13) Egypt 20 min - max 50 100% M 40 smokers divided into: MMN and P300 MMN: significant increase in wave amplitude and latency in smokers. Smokers have a delay in processing information. Thus, chronic smoking can produce cognitive dysfunction.
20 smokers (20 cigarettes a day)
20 light smokers (<20 cigarettes a day) P300: decrease in P3 amplitude in relation to smokers, with no difference between latency values.
40 non-smokers
Guney et al.(21) Turkey Smokers 40.59 years ± 13.11; non-smokers: 37.09 ± 10.01 56 smokers: 25% M (n=18); 43.75% F (n=14) 32 smokers P300 Decreased amplitude and increased latency of N1 (in FZ) for smokers. Chronic smoking can produce prefrontal cognitive dysfunction. Recommendation is that the P300 should be used in psychiatric patients, where the incidence of smoking is higher.
Non-smokers: 50% M (n=16); 50% F (n=16) 32 non-smokers
Kumar and Tandon.(22) India 26.55 ± 3.36 100% M 10 smokers BAEP Significant increase in the absolute latency of waves I and III in smokers. There is impairment in the conductivity of the sensory impulse along the nerve and pons in chronic smokers, due to the nicotine and toluene present in cigarettes.
28 non-smokers
Martins et al.(14) Brazil 39.5 years NS 20 smokers BAEP Significant increase in latency of wave I of the right ear and wave V for both ears and increase of interpeak III-V of both ears in smokers. Tobacco is a risk factor for the central auditory nervous system, which can interfere with BAEP latencies and interpeaks in smokers.
20 non-smokers
Mostafa and Kamal.(23) Egypt 34.73 ± +2.98 100% M 15 non-smokers P300 Increased P3 latencies and lower amplitude in the group of smokers compared to non-smokers. Chronic smoking causes decline in cognitive function and increases the electrical activity of the brain. These changes are probably caused by the toxic nicotine effect.
30 smokers
Neuhaus et al.(19) Germany 40.7 ±14.3 48.6% M 84 smokers P300 There was a decrease in the amplitude of the components in smokers and former smokers in relation to non-smokers. Smokers also had lower response amplitude compared to former smokers. There is a difference in the behavior of the P300 responses between non-smokers, former smokers and smokers, pointing to a dysfunction in the generators that contribute to the recording of the components of this potential in smokers.
51.4% F 53 former smokers
110 non-smokers

Caption: NS = Not Specified; M = Male; F = Female; BAEP = Brainstem Auditory Evoked Potential; FZ = Front; MMN = Mismatch Negativity; min = minimum; max = maximum

In the analysis of the methodological quality of the studies included, evaluated according to the JBI Critical Appraisal Checklist for Studies Reporting Prevalence Data(18), one study was classified as having a moderate risk of bias, and seven as having a low risk of bias, according to the number of responses “yes” for the eight questions in the tool adopted for quality assessment(18).

The studies evaluated in this review present data that imply damage in the conductivity of the neural impulse along the auditory pathway in smokers. Of eight studies reviewed - observational studies -, one evidenced the relationship between smoking and the significant increase in the latencies of waves I and III and in the interpeaks I-III and III-V, as well as a decrease in the amplitudes of the BAEP waves(7,14,22), significant increase in wave amplitude and latency of MMN in the group of smokers(13), and also an increase in latencies and lower amplitude in the group of smokers in P300(19-21,23).

Smoking is the main nicotine release way, as each cigarette contains about 9-13 mg nicotine, which is rapidly absorbed and transported by the bloodstream to receptors in the central nervous system(24,25). Nicotinic acetylcholine receptors are widely distributed in the auditory pathways, and it is very plausible that the nicotine absorbed by smoking can influence this pathway, consequently causing conductive, mixed, sensorineural and/or central hearing loss(24,25).

The degeneration of the function of the nervous system is often processed by the organism in a rostrocaudal manner. Thus, it starts with the cortex, passes through the subcortical regions, and then reaches the brainstem(14). Hence the importance of investigating the effects of smoking by recording the AEP, both in the peripheral and central portions, prior to alterations in the basic audiological assessment.

When studying AEP findings in smokers, changes were found in several parameters analyzed, and the possible reason for changes in latency and amplitude of the studied components is due to the reduction in cochlear blood flow induced by nicotine(2). This reduction causes changes in endocochlear potentials, cochlear microphonics and eighth nerve potentials, and nicotine central effects may be due to the alteration in the efferent neural discharge through the olivocochlear system that leads to the modulation of the response of the cochlear hair cells(26).

In the studies that performed BAEP(7,14,22), there was a significant increase in the absolute latency of waves I(7,14,22) and III(7,22) and a significant increase in the interpeaks I-III(7) and III-V(14). Such findings show alteration in the synchrony of the neural element in the sites that generate the response of this potential, in a diffuse manner, evidenced by the delay in the response generation.

The P300 is an endogenous auditory evoked potential, and it is identified as the result of an internal cognitive event generated in an active and voluntary manner during the performance of a specific discriminatory task between two different sound stimuli(27,28). In other words, one of the stimuli is often presented, while the other occurs rarely and randomly. This vertex-positive potential and approximate latency of 300 ms appears once the individual processes a signal at a cognitive level, thus being an execution strategy of the central nervous system manifested electrophysiologically(27,28).

It is known that the brain regions responsible for attention, discrimination, integration, and memory skills, such as the hippocampus, auditory cortex and frontal cortex, are the areas that stand out during the generation of the P300(27,28). In order for the results to be generated, there is joint and integrate activation of the inferior parietal lobe with the medial and lateral prefrontal areas in attention processes, the heteromodal, paralimbic and hippocampus areas in memory processes, and also the auditory cortex involved in discrimination processes and linguistic auditory association(27-29).

To record and analyze the results of this test, parameters such as latency and wave amplitude are considered essential(27-29). Studies suggest that the more significant the frequency difference between the frequent and the rare stimuli is, the more increased the amplitude of the P300, due to the greater ease of detecting the difference between them(27-29). As it is presented by four out of five articles that used this type of AEP, there was a decrease in the amplitude of response in the group of smokers(13,19,21,23), and only one showed absence of significant differences between the values averages between components N1, P2, N2 and P3(20). There was divergence between the observed latency relationship, since part of the studies reported increased latency(23) and specifically increased N1 (in FZ) for the group of smokers(21), and results were also found in which no significant difference values were obtained between latencies(13,20), which shows the need for further studies with this type of potential.

The MMN test is an endogenous auditory evoked potential, which indicates responses to two stimuli, one of which is a rare stimulus and the other a frequent stimulus, which occur bilaterally in the auditory cortex(30). Unlike the P300 test, the MMN does not require the patient’s attention, thus it is capable of providing information about the physiological bases for auditory discrimination without requiring the subject’s speech production(30).

The MMN can be applied as a neural indicator of early auditory variations, often being used in order to observe disorders involving auditory cognition, and its main generators are found in the auditory cortex and receives contributions from the frontal cortex, thalamus, and hippocampus(30,31). Pieces of Research have used the MMN to assess different aspects such as, among other factors, attention and hyperactivity disorder, detection of articulation disorders, and auditory behavior in alcohol or cigarette users(30,31).

The analysis of the MMN is carried out by observing the latency and amplitude of the wave and clinical alterations can be questioned when verifying an increase in latencies or a decrease in amplitudes, where latency informs the course time of the processing activity, while the wave amplitude demonstrates the extent of neural allocation involved in cognitive processes(31-33).

As previously described, nicotine triggers the activation of different receptors that can cause negative effects on the cortex, even compromising cognition(34). Thus, research has been carried out with the use of the MMN to prove the effects caused by tobacco use on the auditory cortex(34). One of these studies selected in this review(13) pointed to a significant increase in wave amplitude and MMN latency in smokers, suggesting that smokers may present delay in information processing, just as chronic smoking can produce cognitive dysfunction.

Finally, based on the data collected and analyzed in this review, there was a predominance of alterations in the AEPs - whether BAEP, P300 or MMN - in smokers without impairment of hearing acuity. The need for more primary studies on this subject is highlighted, especially with performance of the three types of potential in the same study for a better understanding of the clinical implications observed in the same sample unit.

Some limitations can be pointed out in this systematic review, such as: small sample size; lack of studies that applied all AEPs in the same case; convenience samples in all included studies; some studies had only a single sex, and population heterogeneity. Therefore, the results should be analyzed with caution.

CONCLUSION

The results presented by this review show that normal-hearing adult smokers present alterations in the short- and long-latency AEP tests. In the BAEP, the main altered components were the increase in the latencies of waves I and III and in the interpeaks I-III and III-V, as well as a decrease in the amplitude of the waves. In the MMN, there was a significant increase in wave amplitude and latency. In the long latency potential, P300, there was an increase in latencies and a reduction in amplitudes in components N1 (in Fz) and P3.

Footnotes

Study conducted at Departamento de Fonoaudiologia, Universidade Federal de Santa Catarina - UFSC - Florianópolis (SC), Brasil.

Financial support: nothing to declare.

REFERENCES

  • 1.Pinto MT, Pichon-Riviere A, Bardach A. The burden of smoking-related diseases in Brazil: mortality, morbidity and costs. Cad Saude Publica. 2015;31(6):1283–1297. doi: 10.1590/0102-311X00192013. [DOI] [PubMed] [Google Scholar]
  • 2.Cavallieri GV, Alcarás PAS, Corazza MCA, Corazza LA. The hearing of smokers: a review. Rev CEFAC. 2017;3:406–416. doi: 10.1590/1982-0216201719310016. [DOI] [Google Scholar]
  • 3.Gariepy J, Denarie N, Chironi G, Salomon J, Levenson J, Simon A. Gender difference in the influence of smoking on arterial wall thickness. Atherosclerosis. 2000;153(1):139–145. doi: 10.1016/S0021-9150(00)00382-8. [DOI] [PubMed] [Google Scholar]
  • 4.Watts KL. Ototoxicity: visualized in concept maps. Semin Hear. 2019;40(2):177–187. doi: 10.1055/s-0039-1684046. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Hu H, Sasaki N, Ogasawara T, Nagahama S, Akter S, Kuwahara K, et al. Smoking, smoking cessation, and the risk of hearing loss: Japan Epidemiology Collaboration on Occupational Health Study. Nicotine Tob Res. 2019;21(4):481–488. doi: 10.1093/ntr/nty026. [DOI] [PubMed] [Google Scholar]
  • 6.Pezzoli M, Lofaro D, Oliva A, Orione M, Cupi D, Albera A, et al. Effects of smoking on eustachian tube and hearing. Int Tinnitus J. 2017;21(2):98–103. doi: 10.5935/0946-5448.20170019. [DOI] [PubMed] [Google Scholar]
  • 7.Dixit A, Singh YR, Mitra P, Sharma P. Smoking induced alterations in auditory pathways: evidence from evoked potentials. Indian J Physiol Pharmacol. 2020;64:118–122. doi: 10.25259/IJPP_104_2020. [DOI] [Google Scholar]
  • 8.Harkrider AW, Champlin CA, McFadden D. Acute effect of nicotine on non-smokers: OAEs and ABRs. Hear Res. 2001;160(1-2):73–88. doi: 10.1016/S0378-5955(01)00345-8. [DOI] [PubMed] [Google Scholar]
  • 9.Plourde G. Auditory evoked potentials. Best Pract Res Clin Anaesthesiol. 2006;20(1):129–139. doi: 10.1016/j.bpa.2005.07.012. [DOI] [PubMed] [Google Scholar]
  • 10.Anias CR, Limas MAMT, Kós AOA. Evaluation of the influence of age in auditory brainstem response. Rev Bras Otorrinolaringol. 2004;70:84–89. doi: 10.1590/S0034-72992004000100014. [DOI] [Google Scholar]
  • 11.Schochat E, Andrade AN, Takeyama FC, Oliveira JC, Sanches SGG. Auditory processing: comparision between auditory middle latency response and temporal pattern tests. Rev CEFAC. 2009;11:314–322. doi: 10.1590/S1516-18462009000200017. [DOI] [Google Scholar]
  • 12.Soares AJC, Sanches SGG, Neves-Lobo IF, Carvalho RMM, Matas CG, Cárnio MS. Long latency auditory evoked potentials and central auditory processing in children with reading and writing alterations: preliminary data. Arq Int Otorrinolaringol. 2011;15:486–491. doi: 10.1590/S1809-48722011000400013. [DOI] [Google Scholar]
  • 13.El-Shenawy AM, Hosni NA, Hamdy MM, Zirkry SS. Comparison of attention and memory between smokers and non-smokers using P300 & MMN. Al-Azhar Assiut Med J. 2015;13:241–251. [Google Scholar]
  • 14.Martins DMT, Garcia CFD, Baeck HE, Frota S. Brainstem auditory evoked potentials in smokers. Rev CEFAC. 2016;1:47–54. doi: 10.1590/1982-0216201618113915. [DOI] [Google Scholar]
  • 15.Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. doi: 10.1136/bmj.n71. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Canto GDL, Réus JC. In: Revisões sistemáticas da literatura: guia prático. Violin GC, editor. Curitiba: Brazil Publishing; 2020. Mãos à obra; pp. 24–26. [DOI] [Google Scholar]
  • 17.Greenhalgh T, Peacock R. Effectiveness and efficiency of search methods in systematic reviews of complex evidence: audit of primary sources. BMJ. 2005;331(7524):1064–1065. doi: 10.1136/bmj.38636.593461.68. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.The Joanna Briggs Institute . The Joanna Briggs Institute critical appraisal tools for use in JBI systematic reviews. Checklist for prevalence studies. Adelaide: The Joanna Briggs Institute; 2017. [Google Scholar]
  • 19.Neuhaus A, Bajbouj M, Kienast T, Kalus P, von Haebler D, Winterer G, et al. Persistent dysfunctional frontal lobe activation in former smokers. Psychopharmacology. 2006;186(2):191–200. doi: 10.1007/s00213-006-0366-7. [DOI] [PubMed] [Google Scholar]
  • 20.Aşçioglu M, Dolu N, Gölgeli A, Süer C, Özesmi Ç. Effects of cigarette smoking on cognitive processing. Int J Neurosci. 2004;114(3):381–390. doi: 10.1080/00207450490270668. [DOI] [PubMed] [Google Scholar]
  • 21.Guney F, Genc BO, Kutlu R, Ilhan BC. Auditory P300 event-related potential in tobacco smokers. J Clin Neurosci. 2009;16(10):1311–1315. doi: 10.1016/j.jocn.2008.11.025. [DOI] [PubMed] [Google Scholar]
  • 22.Kumar V, Tandon OP. Brainstem auditory evoked potentials (BAEPs) in tobacco smoker. Indian J Physiol Pharmacol. 1996;40(4):381–384. [PubMed] [Google Scholar]
  • 23.Mostafa S, Kamal S. Cognitive function and electroencephalogram in chronic tobacco smokers. Egypt J Neurol Psychiat Neurosurg. 2009;46:377–383. [Google Scholar]
  • 24.Veltri T, Taroyan N, Overton PG. Nicotine enhances an auditory event-related potential component which is inversely related to habituation. J Psychopharmacol. 2017;31(7):861–872. doi: 10.1177/0269881117695860. [DOI] [PubMed] [Google Scholar]
  • 25.Martin LF, Davalos DB, Kisley MA. Nicotine enhances automatic temporal processing as measured by the mismatch negativity waveform. Nicotine Tob Res. 2009;11(6):698–706. doi: 10.1093/ntr/ntp052. [DOI] [PubMed] [Google Scholar]
  • 26.Paschoal CP, Azevedo MF. Cigarette smoking as a risk factor for auditory problems. Braz J Otorhinolaryngol. 2009;75(6):893–902. doi: 10.1016/S1808-8694(15)30556-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Sousa LCA, Piza MRT, Alvarenga KF, Cóser PL. Eletrofisiologia da audição e emissões otoacústicas: princípios e aplicações clínicas. 3ª. Ribeirão Preto: Book Toy; 2016. [Google Scholar]
  • 28.Didoné DD, Garcia MV, Oppitz SJ, Silva TFF, Santos SN, Bruno RS, et al. Auditory evoked potential P300 in adults: reference values. Einstein. 2016;14(2):208–212. doi: 10.1590/S1679-45082016AO3586. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Reis ACMB, Frizzo ACF. Tratado de audiologia. 2ª. São Paulo: Santos; 2015. Potencial evocado auditivo cognitivo; pp. 140–150. [Google Scholar]
  • 30.Roggia SM. Tratado de audiologia. 2ª. São Paulo: Santos; 2015. Mismatch negativity (MMN) pp. 151–159. [Google Scholar]
  • 31.Brossi AB, Borba KC, Garcia CFD, Reis ACMB, Isaac ML. Verification of the Mismatch Negativity (MMN) responses in normal adult subjects. Rev Bras Otorrinolaringol. 2007;73(6):793–802. doi: 10.1590/S0034-72992007000600011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Romero ACL, Regacone SF, Lima DDB, Menezes PL, Frizzo ACF. Event-related potentials in clinical research: guidelines for eliciting, recording, and quantifying Mismatch Negativity, P300, and N400. Audiol Commun Res. 2015;20:52–53. [Google Scholar]
  • 33.Ferreira DA, Bueno CD, Costa SS, Sleifer P. Applicability of Mismatch Negativity in the child population: systematic literature review. Audiol Commun Res. 2017;22:1831. doi: 10.1590/2317-6431-2016-1831. [DOI] [Google Scholar]
  • 34.Dani JA, Bertrand D. Nicotinic acetylcholine receptors and nicotinic cholinergic mechanisms of the central nervous system. Annu Rev Pharmacol Toxicol. 2007;47(1):699–729. doi: 10.1146/annurev.pharmtox.47.120505.105214. [DOI] [PubMed] [Google Scholar]
Codas. 2023 Aug 4;35(4):e20210273. [Article in Portuguese] doi: 10.1590/2317-1782/20232021273pt

Ocorrência de alterações nos potenciais evocados auditivos de fumantes: revisão sistemática da literatura

Dayane Stephanie Potgurski 1, Georgea Espindola Ribeiro 2, Daniela Polo Camargo da Silva 1,

RESUMO

Objetivo

Verificar a ocorrência de alterações nos exames de potencial evocado (PEA) auditivo em adultos fumantes normo-ouvintes.

Estratégia de pesquisa

Revisão sistemática da literatura de acordo com recomendações do PRISMA, buscando responder à pergunta: “Há alterações nos resultados do exame de PEA em adultos fumantes?”, estratégia PECOS. Pesquisa realizada nas bases de dados PubMed, Embase, CINAHL, LIVIVO, Scopus, Web of Science, LILACS e Scielo. Busca adicional da literatura cinzenta: Google Scholar e ProQuest e busca manual das referências dos estudos incluídos.

Critérios de seleção

Foram selecionados estudos com delineamento transversal, sem restrição do ano de publicação e idioma.

Análise dos dados

Primeiramente foram analisados os títulos e resumos de todos os estudos encontrados, seguido da leitura na íntegra dos estudos elegíveis.

Resultados

Foram obtidos 898 artigos, que após remoção dos duplicados e análise cega por três pesquisadores, foram selecionados oito trabalhos. Grande parte dos estudos encontrou uma associação entre tabagismo ativo e alterações nos testes eletrofisiológicos.

Conclusão

Adultos fumantes normo-ouvintes apresentam alterações nos exames de PEA de curta e longa latência. No potencial evocado auditivo de tronco encefálico, os principais componentes alterados foram o aumento das latências das ondas I e III e nos interpicos I - III e III - V, bem como diminuição da amplitude das ondas. No Mismatch Negativity, houve aumento significativo da amplitude da onda e da latência. No potencial de longa latência, P300, houve aumento das latências e redução das amplitudes nos componentes N1 (em Fz) e P3.

Descritores: Fumante, Eletrofisiologia, Audição, Nervo Coclear, Potenciais Evocados Auditivos

INTRODUÇÃO

O consumo de tabaco é considerado como um dos fatores de risco que mais provocam a morbimortalidade em todo o mundo e sabe-se que o seu consumo é o principal meio de liberação de nicotina, que é altamente absorvida na corrente sanguínea, podendo comprometer diferentes estruturas do organismo, provocando diversos efeitos nocivos, como doenças cardíacas, acidente vascular cerebral, doença pulmonar obstrutiva crônica, além de cânceres, comprometimento cognitivo dentre outras(1,2).

O tabaco também provoca diminuição da oxigenação celular, bloqueio vascular, mudanças na viscosidade sanguínea, formação de placa aterosclerótica e diminuição do aporte de oxigênio, que pode levar a um prejuízo no suprimento sanguíneo, inclusive, das vias auditivas(1-3).

Sendo assim, o sistema auditivo pode sofrer influências danosas deste evento adverso e, se tratando da ototoxicidade, seus efeitos podem ser transitórios ou permanentes, a depender de quais estruturas foram acometidas ou então das características da exposição(4). E também como qualquer tipo de comprometimento auditivo pode levar a uma piora da qualidade de vida do indivíduo, muitos autores têm explorado a associação entre o uso do tabaco e seu efeito na audição, ao longo dos anos(5).

Um estudo recente verificou a associação prospectiva do tabagismo, a intensidade e a cessação do vício com o risco de perda auditiva, em um delineamento de coorte, por oito anos, que incluiu 50.195 participantes, com idade entre 20 e 64 anos e sem perda auditiva no início do estudo. A audiometria tonal liminar foi feita anualmente e durante o acompanhamento, 3.532 indivíduos desenvolveram perda auditiva nas altas frequências e 1.575 desenvolveram perda de audição nas baixas frequências. Concluíram que o tabagismo está associado a um risco aumentado de perda auditiva, especialmente nas altas frequências, de forma dose-resposta. O risco excessivo de perda auditiva, associado ao tabagismo, desapareceu em um período relativamente curto após a cessação do vício(5).

Além da ocorrência de perda auditiva sensorioneural nas altas frequências, um estudo também observou a presença de um elevado número de fumantes com disfunção tubária, que aumentam a incidência de doenças da orelha média, por trazer sintomas inespecíficos caracterizados por plenitude auricular e dificuldade de equalização da orelha média(6).

E ainda, a nicotina pode ser transportada aos receptores do sistema nervoso central podendo envolver tanto estruturas auditivas periféricas como centrais(1,7). Além do mais, sabe-se que a degradação da função do sistema nervoso, em sua maioria, acontece de forma rostrocaudal, ou seja, inicia-se pelo córtex, passando pelas regiões subcorticais até atingir o tronco encefálico(8). Assim, a investigação do efeito da nicotina sobre o sistema nervoso auditivo central (SNAC) tem sido também investigado através do potencial evocado auditivo (PEA).

O PEA trata-se de um conjunto de métodos que avaliam a atividade eletrobiológica, ao longo do sistema auditivo, desde orelha interna ao córtex cerebral. Dessa forma, a aplicação destes testes permite investigar condições neurofisiológicas da audição(9).

Dentres os PEAs destaca-se: o potencial evocado auditivo de tronco encefálico (PEATE) considerado um potencial de curta latência, que surge em um intervalo de aproximadamente 10 ms, o mesmo permite a análise neurofisiológica da via auditiva, desde a orelha interna até o tronco encefálico alto(10). O potencial evocado auditivo de média latência que surge em aproximadamente 80 ms após a estimulação, originando-se em áreas primárias do córtex auditivo, mais especificamente dos núcleos e vias auditivas existentes até no nível da região tálamo-cortical e córtex auditivo primário(11), por fim o potencial evocado auditivo de longa latência que surge por volta de 100 a 700 ms após a estimulação, refletindo atividades da via auditiva nas regiões do tálamo e córtex auditivo, fornecendo informações sobre o funcionamento do sistema nervoso auditivo central (SNAC)(12).

Desta forma, perdas auditivas sensorioneurais nas altas frequências de origem coclear comprometem a morfologia das ondas dos PEAs, assim como disfunções retrococleares. Neste sentido, estudos apontam que há alteração nos parâmetros de registros de exames de PEA, tais como aumento das latências e diminuição das amplitudes das respostas, em fumantes quando comparados aos não fumantes, mesmo na ausência da elevação dos limiares auditivos, sendo que esses achados podem influenciar, de alguma maneira, o correto processamento da informação acústica(7,13,14).

É provável que diversos sítios anatômicos, responsáveis pela produção da atividade neuroelétrica da via auditiva, em resposta a uma estimulação acústica, se comporte de forma diferente em fumantes, o que torna necessário avaliar quais são as evidências disponíveis na literatura que comprovem a existência ou não dessa associação.

Diante do exposto acima, estudos têm apontado a necessidade de se realizar testes complementares a avaliação audiológica básica a fim de se investigar a extensão da lesão ocasionada pela exposição constante ao tabaco e auxiliar no melhor entendimento das alterações encontradas, além de detalhar os tipos de alterações que o fumo ocasiona ao SNAC(2,7,13,14).

Assim, a investigação dos PEAs se mostra útil no diagnóstico diferencial da perda auditiva sensorioneural trazendo informações importantes que podem objetivamente indicar se a lesão está situada em nível coclear e/ou retrococlear, bem como mostrar alteração precoce nos sítios geradores da resposta neural, antes de se detectar mudanças na avaliação audiológica básica(2,7,13,14).

OBJETIVO

Desse modo, o objetivo do presente estudo foi verificar a ocorrência de alterações nos exames de PEA em adultos fumantes normo-ouvintes, por meio de uma revisão sistemática da literatura.

Estratégia de pesquisa

Esta revisão sistemática seguiu as recomendações do Preferred Reporting Items for Systematic Reviews and Meta-analyses - PRISMA(15).

Foram considerados elegíveis para essa revisão sistemática estudos observacionais realizados em adultos (idade maior ou igual a 18 anos e menores de 60 anos) tabagistas, que tiveram como objetivo avaliar a integridade da via auditiva por meio do exame de PEA. Não houve restrição do tempo de publicação dos estudos. Foram excluídos os seguintes estudos: (1) artigos de revisão, cartas, estudos de caso e resumos para eventos; (2) estudos realizados em fumantes associados com outras doenças; (3) estudos que incluíram indivíduos com idade inferior a 18 anos ou maiores de 60 anos; (4) estudos realizados em fumantes com alterações auditivas prévias ao vício; (5) estudos sem grupo controle; (6) estudos que não tinham a versão na íntegra disponível.

Para a condução do estudo foi utilizada a seguinte pergunta norteadora: “Há alterações nos resultados do exame de potenciais evocados auditivos em adultos fumantes?”. Esta pergunta foi organizada no formato PECOS(16) (Patient, Exposure, Comparison, Outcomes, Studies). Assim, o acrônimo (P) consiste em população (adultos), (E) consiste na exposição ao tabaco, (O) consiste em qualquer alteração nos exames de potenciais evocados auditivos, (C) adultos sem exposição ao tabaco e (S) consiste no desenho de estudos incluídos, observacionais - transversais.

Foram desenvolvidas estratégias de busca eletrônica individual, sendo utilizada a combinação dos seguintes descritores em português e em inglês, respectivamente: “Fumantes”, “Potenciais Evocados Auditivos”, “Eletrofisiologia”, “Nervo Coclear”, “Smokers”, “Auditory Evoked Potentials”, “Electrophysiology”, “Cochlear Nerve”. Para contemplar os determinados eixos temáticos, foram utilizados os operadores booleanos “OR” e “AND”, de acordo com MESH/DECS, para cada uma das seguintes bases de dados: PubMed, Embase, CINAHL, LIVIVO, Scopus, Web of Science, LILACS, Scielo. Uma pesquisa adicional da literatura cinzenta foi realizada acessando o Google Scholar e ProQuest. Além disso, foram realizadas buscas manuais das referências dos estudos incluídos, conforme recomendado por Greenhalgh e Peacock(17). Um software gerenciador de referência (EndNote Web®) foi usado para coletar as referências e excluir as duplicatas. A data de coleta nas bases foi realizada no dia 24 de março de 2021. Foram selecionados os estudos que responderam a pergunta de pesquisa, sem restrição da data de publicação e idioma.

Critérios de seleção

A etapa de seleção foi realizada em duas fases. Na fase um, os títulos e resumos de todas as citações do banco de dados identificadas foram selecionados de forma independente por dois revisores. Os estudos que não preencheram os critérios de elegibilidade foram excluídos. Na fase dois, os mesmos dois revisores aplicaram os critérios de elegibilidade ao texto completo dos estudos. Um terceiro revisor foi consultado em caso de desacordo que não tenha sido resolvido por uma discussão de consenso entre os dois revisores.

Análise dos dados

Dois autores coletaram as informações necessárias dos estudos selecionados. Um terceiro autor confirmou a veracidade das informações coletadas por meio da conferência do texto completo dos artigos com as informações selecionadas pelos dois primeiros autores. Quaisquer controvérsias, neste processo, foram discutidas e estabelecido um consenso. Os dados extraídos dos estudos foram: características dos estudos (autores, ano de publicação, país, tipo de estudo), características da população (tamanho da amostra, faixa etária do grupo estudado), característica de exposição (caracterização do tabagismo) e características do desfecho (tipo de alteração encontrada na via auditiva retrococlear, tipo de PEA utilizado e principais achados apresentadas pelos estudos).

A avaliação do risco de viés dos estudos selecionados foi avaliada pelo JBI Critical Appraisal Checklist for Studies Reporting Prevalence Data (18). O primeiro e o segundo autores realizaram esta avaliação de forma independente. Quaisquer discordâncias surgidas foram resolvidas com a ajuda do terceiro autor.

Para cada domínio da ferramenta foi atribuída uma das seguintes respostas: “Yes”, “No”, “Unclear” ou “Not Applicable(13). Para a porcentagem de “Yes” de cada estudo analisado, foi considerado com risco alto de viés (> 49%) ou moderado (50 a 69%) ou baixo (> 70%).

RESULTADOS

A primeira fase do processo de seleção resultou em 898 citações nas bases de dados eletrônicas. Após a remoção de duplicados, um total de 537 foi avaliado. Após a leitura de títulos e resumos, 47 referências foram selecionadas para serem triadas por meio da leitura do texto na íntegra, o que resultou na inclusão de oito estudos para avaliação qualitativa e quantitativa. Foi adicionado um artigo novo após a pesquisa na lista de referências dos artigos incluídos. Tanto a seleção quanto os processos de exclusão são apresentados na Figura 1.

Figura 1. Fluxograma de pesquisa da literatura e critérios de seleção.

Figura 1

Fonte: Adaptado do PRISMA

Os artigos incluídos foram publicados em diferentes revistas científicas (total de oito). O número de fumantes incluídos nos estudos variou de 1019 a 137(19). Em relação ao país de origem dos estudos, um foi do Brasil(14), dois foram da Turquia(20,21), dois foram da Índia(7,22), dois foram do Egito(13,23) e um da Alemanha(19). Devido a natureza da pergunta norteadora, todos os estudos incluídos usaram amostras de conveniência. A síntese das características dos oito estudos incluídos pode ser encontrada no Quadro 1. Em relação ao exame realizado, três executaram o PEATE(7,14,22), quatro realizaram o P300(19-21,23) e um o MMN e o P300(13).

Quadro 1. Síntese dos estudos incluídos.

Autor País Idade (média em anos) Sexo (%) Tamanho da amostra Exame Utilizado Desfechos audiológicos Conclusões
Aşçioglu et al.(20) Turquia 23 ± 2,3 NE 10 fumantes crônicos P300 Não houve diferenças significativas entre os valores médios de latência ou amplitude entre os grupos (N1, P2, N2 e P300). O tabagismo crônico não interferiu na resposta do P300.
10 não fumantes
Dixit et al.(7) Índia Fumantes: 28,7 ± 2,7 100% M 30 fumantes crônicos PEATE Aumento significativo das latências das ondas I e III e no interpico I - III, bem como diminuição das amplitudes das ondas nos participantes fumantes. O tabagismo crônico afeta a via auditiva.
Não fumantes: 26,9 ± 1,8 30 não fumantes
El-Shenawy et al.(13) Egito 20 mín - máx 50 100% M 40 fumantes subdivididos em: MMN e P300 MMN: aumento significativo da amplitude da onda e da latência no grupo de fumantes. Fumantes apresentam atraso no processamento da informação. Assim, o tabagismo crônico pode produzir disfunção cognitiva.
20 fumantes (20 cigarros por dia)
20 fumantes leves (< 20 cigarros por dia) P300: diminuição da amplitude de P3 em relação aos fumantes, sem diferença entre os valores das latências.
40 não fumantes
Guney et al.(21) Turquia Fumantes: 40,59 anos ± 13,11; Não fumantes: 37,09 anos ± 10,01 56 Fumantes: 25% M (n=18); 43,75% F (n=14) 32 fumantes P300 Diminuição da amplitude e aumento da latência de N1 (em FZ) para o grupo de fumantes. O tabagismo crônico pode produzir disfunção cognitiva pré-frontal. Recomendam o uso do P300 em pacientes psiquiátricos, onde a incidência do tabagismo é maior.
Não fumantes: 50% M (n=16) 50% F (n=16) 32 não fumantes
Kumar e Tandon.(22) Índia 26,55 ± 3,36 100% M 10 Fumantes PEATE Aumento significativo da latência absoluta das ondas I e III nos fumantes. Há prejuízo na condutividade do impulso sensorial ao longo do nervo e ponte em fumantes crônicos, em decorrência da nicotina e tolueno presentes no cigarro.
28 não fumantes
Martins et al.(14) Brasil 39,5 anos NE 20 fumantes PEATE Aumento significativo da latência da onda I da orelha direita e da onda V para ambas as orelhas e aumento do interpico III - V de ambas as orelhas em tabagistas Tabaco é um fator de risco para o sistema nervoso auditivo central, que pode interferir nas latências e interpicos do PEATEde tabagistas.
20 não fumantes
Mostafa e Kamal.(23) Egito 34,73 ± 2,98 100% M 15 não fumantes P300 Aumento das latências e amplitude menores de P3 no grupo de fumantes em relação aos não fumantes. O tabagismo crônico causa declínio da função cognitiva, aumenta a atividade elétrica do cérebro. Essas mudanças provavelmente resultam do efeito tóxico da nicotina.
30 fumantes
Neuhaus et al.(19) Alemanha 40,7 ± 14,3 48,6% M 84 fumantes P300 Houve diminuição da amplitude dos componentes no grupo de fumantes e ex-fumantes em relação aos não fumantes. Os fumantes também apresentaram menor amplitude de resposta em relação aos ex-fumantes. Há diferença no comportamento das respostas do P300 entre não fumantes, ex fumantes e fumantes, apontando uma disfunção nos geradores que contribuem para o registro dos componentes desse potencial nos indivíduos fumantes.
51,4% F 53 ex-fumantes
110 não fumantes

Legenda: NE = Não Especificado; M = Sexo Masculino; F = Feminino; PEATE = Potencial Evocado Auditovo de Tronco Encefálico; FZ = Frontal; MMN = Mismatch Negativity; mín = mínimo; máx = máximo

Na análise da qualidade metodológica dos estudos incluídos, avaliado de acordo com JBI Critical Appraisal Checklist for Studies Reporting Prevalence Data (18), um estudo foi classificado como tendo moderado risco de viés, e sete com baixo risco de viés, de acordo com o número de respostas “sim” para as oito perguntas na ferramenta adotada para a avaliação da qualidade(18).

Os estudos avaliados nesta revisão mostram dados que implicam em prejuízos na condutividade do impulso neural ao longo da via auditiva em indivíduos fumantes. A partir de oito trabalhos revisados, sendo estes com tipo de estudo observacional, evidenciou-se a relação entre o tabagismo com o aumento significativo das latências das ondas I e III e nos interpicos I - III e III - V, bem como diminuição das amplitudes das ondas do potencial evocado auditivo de tronco encefálico (PEATE)(7,14,22), aumento significativo da amplitude da onda e da latência do Mismatch Negativity (MMN) no grupo de fumantes(13) e ainda, aumento das latências e amplitude menores no grupo de fumantes no exame P300(19-21,23).

O tabagismo é o principal sistema de liberação da nicotina, pois cada cigarro contém cerca de 9-13 mg de nicotina que é rapidamente absorvida e transportada pela corrente sanguínea aos receptores no sistema nervoso central(24,25). Os receptores nicotínicos de acetilcolina têm ampla distribuição nas vias auditivas, o que é muito provável que a nicotina absorvida pelo fumo possa exercer influência nesta via, e consequentemente provocar perdas auditivas de natureza condutiva, mista, sensorioneural e/ou central(24,25).

A deterioração da função do sistema nervoso central muitas vezes é processada pelo organismo de forma rostro-caudal. Sendo assim, inicia-se pelo córtex, passa pelas regiões subcorticais quando então atinge o tronco encefálico(14). Daí a importância da investigação dos efeitos do tabagismo por meio do registro dos PEA, tanto na porção periférica como central, previamente a alterações na avaliação audiológica básica.

Ao estudar os achados dos PEA em fumantes encontram-se mudanças em diversos parâmetros analisados e a possível razão para as alterações na latência e nas amplitudes dos componentes estudados se deve ao fato da redução do fluxo sanguíneo coclear induzida pela nicotina(2). Esta redução causa mudanças nos potenciais endococleares, no microfonismo coclear e nos potenciais do oitavo nervo e é possível também que os efeitos centrais da nicotina são em decorrência da alteração na descarga neural eferente através da sistema olivococlear que leva à modulação da resposta das células ciliadas da cóclea(26).

Para os estudos que realizaram o PEATE(7,14,22), observou-se aumento significativo da latência absoluta das ondas I(7,14,22) e III(7,22) e aumento significativo do interpico I - III(7) e III - V(14). Tais achados mostram alteração na sincronia do elemento neural nos sítios geradores da resposta deste potencial, de forma difusa, evidenciado pelo atraso na formação da resposta.

O P300 é um potencial evocado auditivo endógeno, sendo designado como o resultado de um evento cognitivo interno gerado de forma ativa e voluntária durante o desempenho de uma tarefa discriminatória específica entre dois estímulos sonoros diferentes entre si(27,28). Ou seja, um dos estímulos é apresentado de forma frequente, enquanto que o outro ocorre raramente e de forma aleatória. Este potencial de vértex-positivo e latência aproximada de 300 ms aparece uma vez que o indivíduo processe um sinal em nível cognitivo, sendo assim uma estratégia de execução do sistema nervoso central manifestada eletrofisiologicamente(27,28).

Sabe-se que as regiões cerebrais responsáveis pelas habilidades de atenção, discriminação, integração e memória, como por exemplo o hipocampo, córtex auditivo e o córtex frontal, são as áreas que se sobressaem durante a geração do P300(27,28). Para que os resultados sejam gerados, são ativadas de forma conjunta e integrada o lobo parietal inferior com áreas pré frontais medial e lateral nos processos de atenção, das áreas paralímbicas heteromodais e do hipocampo nos processos de memória e, ainda, o córtex auditivo envolvidos nos processos de discriminação e associação auditivo linguística(27-29).

Para registro e análise dos resultados deste teste, parâmetros como latência e amplitude de onda são considerados fundamentais(27-29). Estudos sugerem que a amplitude do P300 aumenta quanto mais significativa for a diferença de frequência entre o estímulo frequente e o raro, devido a maior facilidade de detecção da diferença entre eles(27-29). As pesquisas selecionadas evidenciam que se tratando de sujeitos fumantes, quatro dos cinco artigos que utilizaram este tipo de PEA, houve diminuição da amplitude de resposta no grupo de fumantes(13,19,21,23), apenas um deles evidenciou ausência de diferenças significativas entre os valores médios entre os componentes N1, P2, N2 e P3(20). Houve divergência entre a relação das latências observadas, uma vez que parte dos estudos referiu aumento da latência(23) e especificamente aumento de N1 (em FZ) para o grupo de fumantes(21), também foram encontrados resultados em que não foram obtidos valores de diferença significativa entre as latências(13,20), o que mostra a necessidade de mais estudos com este tipo de potencial.

O teste Mismatch Negativity (MMN) é um potencial evocado auditivo endógeno, que indica respostas de dois estímulos, sendo um deles o estímulo raro e o outro, um estímulo frequente, os quais ocorrem bilateralmente no córtex auditivo(30). Diferente do teste P300, o MMN não requer a atenção do paciente, sendo assim capaz de fornecer informações sobre as bases fisiológicoas para a discriminação auditiva, sem requerer a produção da fala do sujeito(30).

O MMN pode ser aplicado como um indicador neural de variações auditivas precoces, sendo muitas vezes, aplicado a fim de se observar transtornos envolvendo a cognição auditiva, e seus principais geradores encontram-se no córtex auditivo e recebe contribuições do córtex frontal, tálamo e hipocampo(30,31). Pesquisas têm utilizado o MMN para avaliar diferentes aspectos como: transtorno de atenção e hiperatividade, detecção de distúrbios articulatórios, comportamento auditivo em usuários de álcool ou cigarro entre outros fatores(30,31).

A análise do MMN é realizada através da observação da latência e amplitude da onda e ao se verificar aumento das latências ou diminuição das amplitudes, alterações clínicas podem ser questionadas, sendo que a latência informa o tempo de curso da atividade do processamento, enquanto que a amplitude da onda demonstra a extensão da alocação neural envolvida nos processos cognitivos(31-33).

Como descrito anteriormente, a nicotina provoca a ativação de diferentes receptores que podem ocasionar efeitos negativos ao córtex comprometendo até mesmo a cognição(34). Dessa forma, pesquisas têm sido feitas com o uso do MMN para comprovar os efeitos provocados pelo uso do tabaco no córtex auditivo(34). Um desses estudos selecionados na presente revisão(13), apontou aumento significativo da amplitude da onda e da latência do MMN nos fumantes, sugerindo que sujeitos fumantes possam apresentar atraso no processamento da informação, assim como o tabagismo crônico pode produzir disfunção cognitiva.

Por fim, a partir dos dados coletados e analisados nesta revisão, houve predomínio de alterações em qualquer um dos PEA, seja PEATE, P300 ou MMN, em indivíduos fumantes sem prejuízo da acuidade auditiva. Destaca-se a necessidade de mais estudos primários sobre este assunto, principalmente na realização dos três tipos de potencial num mesmo estudo para melhor entendimento das implicações clínicas observadas numa mesma unidade amostral.

Algumas limitações podem ser apontadas nesta revisão sistemática, como o pequeno número da amostra dos estudos incluídos, não foi encontrado estudos que aplicassem todos os PEAs na mesma casuística, todos os estudos incluídos foram conduzidos com amostras de conveniência, alguns eram restritos a um único sexo, e a heterogeneidade da população deve ser considerada, portanto, os resultados devem ser analisados com cautela.

CONCLUSÃO

Os resultados apresentados por esta pesquisa evidenciam que adultos fumantes normo-ouvintes apresentam alterações nos exames de PEA de curta e longa latência. No PEATE, os principais componentes alterados foram o aumento das latências das ondas I e III e nos interpicos I - III e III - V, bem como diminuição da amplitude das ondas. No MMN, houve aumento significativo da amplitude da onda e da latência. No potencial de longa latência, P300, houve aumento das latências e redução das amplitudes nos componentes N1 (em Fz) e P3.

Footnotes

Trabalho realizado no Departamento de Fonoaudiologia, Universidade Federal de Santa Catarina - UFSC - Florianópolis (SC), Brasil.

Fonte de financiamento: nada a declarar.


Articles from CoDAS are provided here courtesy of Sociedade Brasileira de Fonoaudiologia

RESOURCES