Comparison of the 3D-microstructure of human alveolar and fibula bone in microvascular autologous bone transplantation: a synchrotron radiation μ-CT study

Jonas Wüster 1,*, Bernhard Hesse 2,3, Rene Rothweiler 4, Emely Bortel 2, Christian Gross 4, Shima Bakhtiyari 2, Andrew King 5, Elodie Boller 3, Javier Gerber 2, Carsten Rendenbach 1, Tobias Fretwurst 4, Saskia Preissner 1, Max Heiland 1, Katja Nelson 4, Susanne Nahles 1
PMCID: PMC10486015  PMID: 37691907

Abstract

Introduction: Autologous bone transplantation is successfully used in reconstructive surgery of large/critical-sized bone defects, whereby the microvascular free fibula flap is still regarded as the gold standard for the reconstruction of such defects in the head and neck region. Here, we report the morphological and lacunar properties of patient-paired bone samples from eight patients from the jaw (AB; recipient site) and the fibula (FB; donor site) on the micron length-scale using Synchrotron µ-CT. Insights into differences and similarities between these bone structures could offer a better understanding of the underlying mechanism for successful surgical outcomes and might clear the path for optimized, nature-inspired bone scaffold designs.

Methods: Spatial vessel-pore arrangements, bone morphology, fluid-simulation derived permeability tensor, osteocyte lacunar density, and lacunar morphology are compared.

Results: The orientation of the vessel system indicates a homogenous vessel orientation for AB and FB. The average mineral distance (50%) to the closest vessel boundary is higher in AB than in FB (the mean is 96 μm for AB vs. 76 μm for FB; p = 0.021). Average osteocyte lacunar density is found to be higher in AB than in FB (mean 22,874 mm3 vs. 19,376 mm3 for FB; p = 0.038), which might compensate for the high distance from the mineral to the nearest vessel. No significant differences in lacunar volume are found between paired AB and FB.

Discussion: A comparable vessel network and similar distribution of vessel porosity between AB and FB may allow the FB graft to exhibit a high regeneration potential when connected to AB, and this might correlate with a high osteoinductive and osteoconductive potential of FB when connected to AB. Since widely used and potent synthetic bone grafts exist, new insight into the bone structure of well-established autologous bone grafts, such as the free fibula flap, could help to improve the performance of such materials and therefore the design of 3D scaffolds.

Keywords: osteocyte lacunae, bone microarchitecture, SR micro-CT, synchrotron, free fibula flap, bone vessel orientation, scaffold

1 Introduction

Bone healing is known to be a complex physiological process involving multiple interacting cells and signalling molecules (Vidal et al., 2020). In general, minor fractures and small bone defects heal spontaneously, whereas critical-sized and/or complex bone defects (CSBDs) still present a challenge in reconstructive surgery. Normally, CSBDs exceed the intrinsic capacity of bone healing, which might lead to delayed or insufficient bone union (Vidal et al., 2020). Defects with a length greater than 1–2 cm and a loss of more than 50% of bone circumference are generally defined as CSBDs in literature (Keating et al., 2005; Sanders et al., 2014). Animal studies demonstrated that the critical size for segmental mandibula defects in minipigs is 6 cm when the periosteum is preserved and 2 cm when the periosteum is removed (Ma et al., 2009). Since bone remodelling in pigs and humans is comparable (1.2–1.5 mm/day vs. 1.0–1.5 mm/day, respectively) (Pearce et al., 2007), these animal studies provide a valuable way to determine CSBD in humans. In oncological head and neck surgery, the required quantity of bone generally exceeds the potential of self-healing and osseous free flaps with microsurgical anastomosis are therefore often needed for reconstruction. The free fibula flap (FFF) has become the gold standard for autologous reconstruction of such defects resulting from oncological head and neck surgery (Fliss et al., 2021). Advantages of FFF are sufficient quantity of bone, possibility of ideal contouring, vascular supply, and a long pedicle (Chaine et al., 2009; López-Arcas et al., 2010; Verhelst et al., 2019; Rosen et al., 2022). Lately, by using CAD/CAM planning for FFF, a high accuracy of reconstruction and improved aesthetic and functional outcome could be achieved (Mahendru et al., 2020).

On the other hand, it is known that FFF harvesting may lead to severe donor site morbidities, which are divided into early and late complications. Early complications include infections, wound dehiscence, and delayed wound healing (Zimmermann et al., 2002; Chaine et al., 2009; Ling and Peng, 2012). Late complications comprise chronic pain, gait abnormality, limited range of motion in the ankle, and reduced sensory deficit and muscle strength, which may especially impair a patient’s quality of life (Chaine et al., 2009; Ling and Peng, 2012). This is linked to a rising demand for a synthetic three-dimensional (3D) bone scaffold with predictable anatomic traits that might replace FFF in the future. Therefore, an understanding of skeletal site-specific 3D microarchitecture as well as the physical and cellular properties of the human jaw as a recipient site and the donor bone is essential. Synchrotron micro computed-tomography (SR µ-CT) of alveolar bone (AB) and iliac crest (IC) reveals a site-specific distribution of the intracortical pore system (IPS) and osteocyte lacunar density (Rothweiler et al., 2022). On a nanostructural level, proteome-based profiling of patient-paired human AB and IC, highlights site-specific and interindividual differences (Fretwurst et al., 2022). These insights into site-specific properties may be important for the understanding of mineral homeostasis as well as mechanical and clinical performance of bone transplants regarding an osseous union with jawbones (Rothweiler et al., 2022) and may help explain the clinical success of IC in major (>5 mm) avascular bone augmentations (Nelson et al., 2006; Heberer et al., 2009; Fretwurst et al., 2015; Troeltzsch et al., 2016).

It is known that a physiological framework promotes superior ingrowth of vessels and migration of osteogenic cells, resulting in improved bone formation (Qu et al., 2021), which is seen as the main driving force for bone regeneration in nonviable and synthetic bone substitute scaffolds (Weber, 2019). Vascularization as a main factor for ideal molecular exchange and functional performance is recognized and has led to promising advances in bone tissue engineering (Sharma et al., 2019; Chen et al., 2020; Gonçalves et al., 2021). The significance of vessel orientation in 3D scaffolds was largely ignored (Sharma et al., 2019) until blood vessel supply, osteocytes, and their lacunar-canaliculi network (LCN) as well as their role in bone metabolism were recently closely examined-for example, in femoral bone (Carter et al., 2013a; Dong et al., 2014; Hesse et al., 2014; Portier et al., 2020).

It is well known that LCN plays a fundamental role in cell–cell contact, nutrition, signalling molecules, and even interactions with extracellular tissue (Hesse et al., 2015; Bortel et al., 2022). Besides the important role of LCN in mechanosensation and transduction processes of osteocytes (Burger and Klein-Nulend, 1999; Vatsa et al., 2008; Schneider et al., 2010), it has been reported that LCN is involved in bone remodelling (Currey, 2014).

To date, SR µ-CT has neither been used in a study to examine bone samples of the fibula bone (FB) as a donor, nor of the jaw bone (AB), as a recipient site in an individual. Further, it is unknown whether bone transplants for microsurgical anastomosis require specific morphological properties for the reconstruction of CSBDs or if a microarchitecture related to the recipient bone site might be favourable. Moreover, fluid simulation-derived orientation-dependent permeability properties may be of relevance, since a better match in terms of spatial orientation of the FB when connected to AB, could lead to an improved supply of nutrients and subsequently to bony union in the segmental gap. Therefore, the fluid simulation-derived permeability tensor was analysed to gain insights into the orientation-dependent permeability of AB and FB.

In order to provide a better understanding of the microarchitecture of human AB and FB, patient-paired samples were analysed and compared using SR µ-CT down to a voxel-size of 640 nm. It is demonstrated that SR µ-CT represents an ideal tool for 3D imaging of the bone microarchitecture without sample destruction. Additionally, spatial arrangement of the intracortical-pore system as well as osteocyte lacunar density and lacunar morphology were analysed and compared.

2 Materials and methods

The Ethics Committee of the Faculty of Medicine Charité Berlin approved this study (EA4/161/18). The study was performed in accordance with the Helsinki Declaration of 1964 as revised in 2013.

2.1 Patients

In total, 8 patients (females: 3; males: 5; mean age: 60.38 years; age range: 47–73 years) were treated at the Department of Oral and Maxillofacial Surgery, Charité–Universitätsmedizin Berlin, Germany and were consecutively enrolled between September 2018 and May 2020. Seven patients received a partial resection of the mandible, whereas one patient received a resection of the maxilla. A resection of the mandible or the maxilla was required due to oral squamous cell carcinoma (n = 6), basal cell carcinoma (n = 1), or osteosarcoma (n = 1). Primary CAD/CAM-planned reconstruction with a free fibula flap (FFF) was performed in all patients, whereby the CAD/CAM planning procedure followed a previously described workflow (Kreutzer et al., 2022). Informed consent was obtained from all participants included in this study. Patients with medication affecting bone metabolism (e.g., immunosuppressants and antiresorptive agents), were not included in this research.

2.2 Sample harvesting and preparation

In each patient, two bone samples were harvested (one AB and one FB sample). All samples were retrieved using an oscillating saw. The AB samples were taken from the vicinity of the connecting area of the original bone to FFF during bone contouring. Since all FFF’s were CAD/CAM-planned and raised using CAD/CAM templates, the slice of bone between two segments (which was not further used) was taken as the FB sample. Patient data are listed in Table 1.

TABLE 1.

Patient data.

Patient Gender Age (years) Sample Biopsy origin Diagnosis
#
1* # Male 52 54A Mandible region 32/33 OSCC
54F Fibula
2* # Male 60 55A Mandible region 32/33 OS
55F Fibula
3* # Male 62 56A Mandible region 33/34 OSCC
56F Fibula
4* Male 73 57A Mandible region 43 OSCC
57F Fibula
5# Female 53 63A Mandible region 34 OSCC
63F Fibula
6# Female 66 67A Maxilla region 32 BCC
67F Fibula
7# Female 47 68A Mandible region 34 OSCC
68F Fibula
8# Male 70 69A Mandible region 44 OSCC
69F Fibula
N = 8 62.5% male 37.5% female Ø 60.38 years N = 16 Recipient site: 87.5% mandible (n = 7), 12.5% maxilla (n = 1); Donor site: 100% fibula Diagnosis: 75% OSCC (n = 6); 12.5% BCC (n = 1); 12.5% OS (n = 1)

In total, 8 patients were included. All patients’ data such as gender, diagnosis (BCC = basal cell carcinoma; OSCC = oral squamous cell carcinoma; OS = osteosarcoma), age, sample and biopsy origin are provided in this table. *patients included in the 2.27 µm series; #patients included in the 640 nm series.

After harvesting, the bone samples were fixed in 4% neutral buffered formalin. Subsequently, dehydration in ascending alcohol series (water, 70%/80%/96%/100% ethanol) for three days each followed. The samples were defatted in xylene and infiltrated, embedded, and polymerized in Technovit® 9100 New (Heraues Kulzer, Wehrheim, Germany). Technovit® 9100 New was used according to the manufacturer’s manual (Kulzer, 2012). All Technovit® blocks were cut to a size of 5 mm × 5 mm using a band saw (Proxxon S.A., Wecker, Luxembourg).

2.3 Synchrotron computed tomography imaging

Samples of four patients were SR µ-CT scanned at a voxel size of 2.27 µm, and samples from seven patients (including 3 that were analyzed at the 2.27 voxel-size setup) were scanned at 640 nm voxel size to address the difference in bone morphology at two different voxel-sizes [Figures for all samples are listed in Supplementary Figure S1 (2.27 µm), respectively Supplementary Figure S2 (640 nm)]. The imaging of the 640 nm data was performed at Synchrotron Soleil, France. A SR µ-CT setup of the Psiché (PSICHÉ) beamline was used with a beam energy of 45 keV and a sample to detector distance of 45 mm. For each sample, a total of 5600 projections were exposed for 40 ms each and were recorded over an angle of 360° using a Hamamatsu ORCA Flash sCMOS camera. Phase retrieval and image reconstruction was performed using Paganin’s method (Paganin et al., 2002) and a filtered back projection algorithm, respectively with a delta/beta ratio of approximately 65. Data of 2.27 µm voxel-size were acquired at the beamline ID 19 of the European Synchrotron Radiation Facility (ESRF) in Grenoble, France using 46.9 keV beam energy and a sample detector distance of 460 mm. For each sample, 4000 radiographs over an angle of 360° were recorded at an acquisition time per frame of 20 ms. A pco.edge 5.5 camera (PCO AG, Kelheim, Germany) was used. As with the 640 nm data, reconstruction was carried out using Paganin’s method in combination with the conventional filtered back projection algorithm employing a delta/beta ratio of 350 (Paganin et al., 2002).

2.4 Segmentation of samples

For all samples, representative volumes of interest (VOIs) were selected with a particular emphasis on artifact-free and physiological bone anatomy. In FB, cortical regions were chosen; and AB was mostly assigned to the cortical bone. The VOI of the 640 nm scan was set within the VOI scanned at 2.27 µm. Within each VOI, different tissue regions were segmented into mineralized tissue, vessel pores, and osteocyte lacunae. For both voxel-sizes (2.27 and 640 nm), inhouse-developed MATLAB (R2018b, The MathWorks Inc., Natick, MA, United States) scripts combining several different morphological operations were used. To obtain the mineral mask on the binarized data, a closing of all pores (vessel pores and osteocyte lacunae) within the mineralized region was achieved by a Euclidian distance map coupled to a thresholding step. Combining the mineral mask and the inverse of the binarized data resulted in a mask containing vessel pores. Osteocyte lacunae were extracted from the gray value data with a bottom-hat transformation and a following thresholding step. A connected component analysis was used to size and filter osteocyte lacunae between 30 and 8,000 μm3 and with length and width below 130 and 30 µm.

2.5 Digital bone morphometry and osteocyte lacunae segmentation

For all VOIs, the following parameters of bone morphometry were obtained: bone volume (BV), total volume (TV), bone surface area (SA), porosity (1-BV/TV), specific bone surface (SA/BV), osteocyte lacunae density (N.Lc/BV), mineral distance [(50%) L dist,min50 ], mineral distance [(95%) L dist,min95 ], vessel distance [(50%) L dist, vessel50 ], vessel distance [(95%) L dist, vessel95 ], and blood vessel volume (Vv.). Additionally, 640 nm scans were used to extract the shape of the individual lacunae, which were described by the ratio of the lacunae axes lengths (L1/L3; L2/L3; L1/L2, with L1 being the longest and L3 being the shortest axis). A detailed summary of the characterized morphological parameters is given in Table 2.

TABLE 2.

All parameters extracted to characterize bone morphology (Bouxsein et al., 2010; Dempster et al., 2013).

Parameter Symbol Unit Calculation/Reference Voxel-size
Total volume TV mm³ Total bone volume, comprising mineral and pore volumes 2.27 µm
640 nm
Mineral volume BV mm³ 2.27 µm
640 nm
Lacunar volume LcV µm³ 2.27 µm
640 nm
Lacunar porosity LcV/BV % LcV/BV*100 2.27 µm
640 nm
Lacunar density NLc/BV 1/mm3 2.27 µm
640 nm
Mineral distance (50%) Ldist,min50 µm Distance maps, histogram and cumulative summation 2.27 µm
640 nm
Mineral distance (95%) Ldist,min95 µm Distance maps, histogram and cumulative summation 2.27 µm
640 nm
Vessel distance (50%) Ldist, vessel50 µm Distance maps, histogram and cumulative summation 2.27 µm
640 nm
Vessel distance (95%) Ldist, vessel95 µm Distance maps, histogram and cumulative summation (Dong et al., 2014) 2.27 µm
640 nm
Mean value of lacunar volume lac µm3 2.27 µm
640 nm
Standard deviation of lacunar volume σlac µm3 2.27 µm
640 nm
Blood vessel volume VV µm³ 2.27 µm
640 nm
Vessel porosity VV/BV % Vv/BV*100 2.27 µm
640 nm
Level of alignment LOA - Product of the variance of theta sΘ and the variance of phi sΦ (LOA = sΦ sΘ) 2.27 µm
Angle Phi Φ ° Angle between a segment and the z–axis. Phi = 0° if the segment is parallel to a bone´s long axis 2.27 µm
Angle Theta Θ ° Projected angle between a segment and the x–axis. The segment is parallel to a bone’s surface if theta = 0° 2.27 µm
Ratio EV mean EV mean - Mean of the ratios of the eigenvectors of the permeability tensor [(E2/E1) + (E3/E1)]/2 640 nm
PrincipalAxis Length ratio L1/L3 L1/L3 - Ratio of the longest and shortest axes of the osteocyte lacunae 640 nm
Principal Axis Length ratio L1/L2 L1/L2 - Ratio of the longest and second-longest axes of the osteocyte lacunae L1/L2 640 nm
Principal Axis Length ratio L2/L3 L2/L3 - Ratio of the second-longest and shortest axes of the osteocyte lacunae L2/L3 640 nm

2.6 Absolute permeability and tensor of absolute permeability

Fluid simulation was performed for all 2.27 µm scans. The tensor of permeability was calculated through the Absolute Permeability Tensor Calculation module (Thermo Scientific Avizo Software, XLab Module, Version 2020.2). This tensor enables the computation of permeability in all three spatial directions as well as the computation of eigenvectors and their associated eigenvalues. The ratios of three eigenvalues (E1, E2 and E3) to each other were determined to quantify the anisotropic behavior of absolute permeability (with E1>E2>E3). The termination conditions for the simulations were that either the convergence criterion was smaller than 10−5 or the number of iterations reached 106. Tensor calculation is based on a mathematical approach which considers the sample to be representative of an infinite or macroscopic material. It provides the intrinsic permeability tensor by solving the closure problem derived from the Strokes equation by volume averaging (Whitaker, 1999). All samples were computationally aligned in the same way to ensure comparability. Therefore, the bone surface was located within the x–z plane, where the anatomical long axis was parallel to the z-axis of the global coordinate system.

2.7 Quantifying orientation of the vessel pore

Morphological skeletonization was used to extract central segments of all branches of the vessel pore network. The angles theta and phi were computed for every segment of the skeleton to allow a quantification of spatial orientation. Phi is herein defined as the angle between the segment and the z-axis, with phi = 0° meaning that the segment is parallel to the bone’s long axis. Theta is defined as the projected angle between the segment and the x-axis, resulting in a segment that is parallel to the bone’s surface if theta = 0°. Histograms showing the distribution of theta and phi for all segments in each sample were calculated and the variance of the amplitudes of phi and theta was extracted. Highly aligned segments result in heterogeneous histograms with a prominent peak and thus a high variance. In contrast, equally distributed vessel orientations show a homogeneous histogram and thus a small variance. To quantify the alignment of the vessel pores, we used a recently introduced descriptor (Bortel et al., 2022)- the level of alignment (LOA), which is defined as the product of the variance of theta sΘ and the variance of phi sΦ (LOA = sΦ sΘ).

2.8 Statistics

Statistical hypothesis tests (ANOVA, Kruskal–Wallis, Mann–Whitney and t-test) with post hoc testing (Bonferroni) were performed using IBM SPSS Statistics (version 25.0, IBM Corp., Armonk, NY, United States). p-values ≤ 0.05 were considered statistically significant.

3 Results

3.1 Comparison of bone morphometric parameters

The data collected at the ESRF at 2.27 µm voxel-size provided a larger field of view than did the scans collected at PSICHÉ at a higher spatial voxel-size and were thus used to quantify vessel morphology and lacunar density. The data collected at the 640 nm voxel-size provided a small field of view but allowed for the shape analysis of the osteocyte lacunae.

3.2 Bone gross morphology at 2.27 µm voxel-size

SR µ-CT data of the 2.27 µm voxel-size scans (AB, FB and n = 4/each) were successfully segmented and bone gross morphology parameters were extracted as described in Table 2. Figure 1 illustrates bone sample 54F in 3D and the corresponding segmentation. In Figure 1A, it can be observed that the vessel pores in the horizontal slice mainly run perpendicular to this plane. The segmented vessels are labelled in red, while the lacunae are labelled in blue (Figures 1A, B). Orthogonal grey value slices (1C) of the bone of sample 54F are dark grey, indicating air or soft tissue compartments, while bright grey values refer to high densities of the mineralized phase. A 3D rendering of Figure 1A is given in Figure 1D: each of the blue dots refers to a single lacuna (here 18,208 mm3). In the zoom-in in Figure 1F, the lacunae are color-coded according to their volume.

FIGURE 1.

FIGURE 1

2D and 3D representation of raw and segmented data of sample 54F. Mineralized bone tissue is displayed in different shades of grey, while segmented vessels are labeled in red and lacunae in blue. (A) Illustrates a 2D slice inside the bone where the zoomed-in region shown in (B) is displayed. (C) Shows 3D orientation of the bone in various/selected layers. (D) Shows a 3D rendering of the segmented structures, where the bone is virtually cut open to reveal a vessel system and lacunae. (E,F) represent a selected section of D in high resolution. In (F), lacunae are color-coded according to their volume.

The mean vessel porosity was found to be 8.3% for AB and 6.9% for FB. At the same time, the mean vessel distance was higher for AB than it was for FB. This was observed in the mean vessel distance of 50% (AB: 18.5 µm and FB: 13.5 µm) as well as for the mean vessel distance of 95% (AB: 71.5 µm and FB: 47 µm). On average the median distance (i.e. 50%) of the mineralized bone tissue to the closest vessel pore boundary was found to be 96 μm (minimum: 93 μm; maximum: 101 µm) for AB and 76 μm (minimum: 60 μm; maximum: 84 µm) for FB. On average, 95% of mineralized bone was found at a distance of 208 µm (minimum: 188 μm; maximum: 226 µm) for AB and 174 µm (minimum: 125 μm; maximum: 196 µm) for FB from the canal surface. The average lacunar density for AB was found to be 22,874 per mm3 (minimum: 20,228; maximum: 24,108) and 19,376 per mm3 (minimum: 17,882; maximum: 21,873) for FB. A summary of the results is given in Table 3 and a visualization of statistically significant results is provided in Figures 2, 3 (and Supplementary Figure S3).

TABLE 3.

Bone morphological parameters extracted for AB and FB samples at a voxel-size of 2.27 µm.

Sample Vessel porosity (%) Lacunar density (per mm3) Mineral distance (50%) (μm) Mineral distance (95%) (μm) Vessel distance (50%) (μm) Mineral volume in mm3 Vessel distance (95%) (μm) Vessel Surface/Vessel volume (1/mm) Vessel Surface/Total volume (1/mm) Vessel Surface/Bone volume (1/mm)
54A 15.82 20,228 98 226 29 17.5 120 22.8 2.6 2.9
54F 3.82 18,208 84 196 11 28.9 42 53.6 2.0 2.1
55A 3.65 24,108 93 205 10 3.7 43 60.5 2.2 2.3
55F 5.84 17,882 81 195 11 15.2 37 52.5 3.1 3.3
56A 3.22 23,984 93 188 9 13.5 31 59.7 1.9 2.0
56F 6.38 21,873 60 125 10 18.0 33 57.2 3.6 3.9
57A 10.63 23,175 101 213 26 25.3 92 23.1 2.5 2.8
57F 11.62 19,541 78 179 22 21.8 76 28.9 3.4 3.8
t-test p = Not significant 0.038 0.021 Not significant Not significant Not significant Not significant Not significant Not significant Not significant

The bold values provide statistically significant values.

FIGURE 2.

FIGURE 2

Scatterplot showing the Lacunar Density of the 2.27 µm voxelsize setup per mm3 for AB and FB samples 54–57. Blue indicates AB, orange represents FB.

FIGURE 3.

FIGURE 3

Scatterplot showing the relation between Lacunar Density per mm3 (x-axis) and Mineral Distance (50%) (y-axis) for AB (blue) and FB (orange) samples 54–57. Each sample is labelled.

Most parameters showed no significant differences between AB and FB except for lacunar density (p = 0.038) and mineral distance (50%) (p = 0.021).

3.3 Lacunae shape descriptors at 640 nm

As described, gross bone morphology parameters were also determined for 7 patient-paired bone samples at a voxel-size of 640 nm (Table 4). Mean lacunar density per mm3 showed the same trend and was higher for AB (25,145; ranging from 20,978 to 28,416) than it was for FB (21,042; ranging from 17,807 to 23,068), thus revealing significant differences between these bone entities (p = 0.0049). Mean vessel porosity for both bone entities was comparable: it was 5.16% (1.03%–11.27%) for AB and 5.61% (2.91%–8.48%) for FB. For the 640 nm series, lacunae shape descriptors were additionally characterized. The mean volume of the osteocyte lacunae was found to be slightly lower in AB with a mean volume of 553 μm3 (from 303 to 851 μm3) than it was in FB with a mean volume of 601 μm3 (466–698 μm3). Principal axis length ratios were measured and compared. In AB, the mean L1/L3 and L1/L2 was found to be slightly higher (3.0 and 2.3, respectively) than it was in FB (2.9 and 2.1, respectively). Mean L2/L3 was 1.37 for AB and 1.41 for FB. Interestingly, no statistical difference in the volume of the lacunae could be found between AB and FB. Sample 67 A—the only AB harvested from the maxilla showed similar results for the lacunar shape descriptors (Table 4).

TABLE 4.

Lacunar shape descriptors for AB and FB samples examined at 640 nm.

Sample Number of lacunae Mineral volume in mm3 Lacunar density (per mm3) Mean value of the lacunar volume ± SD (μm3) Standard deviation of lacunar volume (μm3) Vessel porosity (%) Principial axis length ratio L1/L3 ± SD (-) Principial axis length ratio L1/L2 ± SD (-) Principial axis length ratio L2/L3 ± SD (-)
54A 55,543 2.65 20,978 627 ± 295 295 11.27 2.9 ± 0.7 2.2 ± 0.7 1.3 ± 0.2
54F 85,134 4.40 19,354 698 ± 280 280 2.91 3.2 ± 0.8 2.2 ± 0.7 1.5 ± 0.3
55A 33,269 1.21 27,470 414 ± 183 183 2.07 2.8 ± 0.9 2.1 ± 0.7 1.4 ± 0.3
55F 48,039 2.33 20,625 657 ± 268 268 3.63 3.1 ± 1.0 2.1 ± 0.7 1.5 ± 0.3
56A 59,501 2.37 25,136 303 ± 145 145 3.41 3.4 ± 1.2 2.6 ± 1.0 1.4 ± 0.2
56F 14,956 0.71 20,975 604 ± 306 436 6.90 2.7 ± 0.8 2.0 ± 0.7 1.4 ± 0.2
63A 16,886 0.71 23,860 559 ± 254 254 1.07 3.2 ± 0.9 2.4 ± 0.8 1.4 ± 0.3
63F 32,253 1.39 23,279 541 ± 237 237 4.87 2.8 ± 0.7 2.2 ± 0.7 1.3 ± 0.2
67A* 10,706 0.42 25,647 431 ± 174 174 9.18 2.8 ± 0.8 2.2 ± 0.7 1.4 ± 0.2
67F 35,523 1.54 23,068 555 ± 251 251 7.24 2.9 ± 0.8 2.2 ± 0.7 1.3 ± 0.2
68A 59,441 2.09 28,416 851 ± 325 325 1.03 3.1 ± 0.8 2.4 ± 0.8 1.3 ± 0.2
68F 22,342 1.01 22,186 466 ± 185 185 5.21 2.7 ± 0.7 2.0 ± 0.7 1.4 ± 0.3
69A 36,837 1.50 24,508 685 ± 315 315 8.11 3.1 ± 0.8 2.3 ± 0.8 1.4 ± 0.3
69F 32,708 1.84 17,807 688 ± 299 299 8.48 3.0 ± 0.8 2.1 ± 0.7 1.5 ± 0.3
p-value 0.9881 Not significant 0.004878 Not significant Not significant Not significant Not significant 0.02946 Not significant
p-value paired 0.9880 Not significant 0.005549 Not significant Not significant Not significant Not significant Not significant Not significant

*Only sample AB was taken from the maxilla.

The bold values provide statistically significant values.

3.4 Impact of voxel-size

For 6 sample scans (54 A, 54 F, 55 A, 55 F, 56 A and 56 F), lacunar densities were compared between two different voxel-sizes (2.27 and 0.64 µm) to assess the impact of field of view positioning and the voxel-size on the lacunar density (Table 5). We found that in 5 out of 6 scans (54 A, 54 F, 55 A, 55 F and 56 A), lacunar density was found to be slightly higher for the high resolution data (Table 5) suggesting that not all lacunae were captured by the 2.27 µm voxel-size setup. For the one scan with the smaller lacunar density, the VOI of the 0.64 µm-setup was the smallest among the compared specimens and could therefore result in being not representative for the computation of the lacunar density and that the selection of a different VOI would likely result in a higher lacunar density.

TABLE 5.

Comparison between the number of lacunae when extracted from 2.27 µm data and 640 nm data.

Sample N.Lc/mm³ of the 2.27 µm data N.Lc/mm³ of the 0.6 µm data Ratio of densities between both voxel-size data
54A 20,228 20,978 1.037
54F 18,208 19,354 1.063
55A 24,108 27,470 1.139
55F 17,882 20,625 1.153
56A 23,984 25,136 1.048
56F 21,873 20,975 0.959

Sample 56F is the only sample with a high number of lacunae in the 2.27 µm scan.

3.5 Orientation of vessel network

The vessel network of AB and FB samples and the angles theta and phi as well as the visualization of the thickness, the volume of the vessels and the cord length are visualized in Figure 4. The skeleton branches are color-coded by angle, and it appears that FB samples have a high degree of alignment.

FIGURE 4.

FIGURE 4

3D rendering of the segmented vessel network of 2.27 µm samples and visualization of skeletons color-coded by angles phi (colour bar: 0°–360°) and theta (colour bar 0°–90°) (column 2–4). Additionally, a visualization of pore network skeletons color-coded and weighed by thickness (colour bar: 0–30 μm) and volume (colour bar: 0 to 5 106 μm3) and cord length (colour bar: 0–900 μm) (column 5–7) are shown. The thicker the vessels displayed, the larger the respective parameter.

The summarized results for the orientation parameters normalized to vessel length (vessel volume) are presented in Table 6. The ratio LOA_FB/LOA_AB is smaller than 1 for samples 54 and 55 and is notable above 1 for samples 56 and 57.

TABLE 6.

Orientation parameters normalised to the vessel length of the 2.27 µm series.

Sample Phi bin var (E-03) Theta bin var (E-03) LOA (E-05) LOA ratio (FB/AB)
54A 5.17 10.29 5.32 0.13
54F 1.03 6.73 0.70
55A 3.98 6.32 2.51 0.61
55F 2.85 5.38 1.53
56A 1.12 5.49 0.62 2.38
56F 2.68 5.50 1.47
57A 1.19 8.47 1.01 2.71
57F 4.82 5.68 2.74

Histograms of the pooled angles for phi and theta, normalized to segment length and volume, indicate a pronounced intensity between ∼35° and ∼55° (theta) for AB. Histograms for phi show pronounced peaks between 40° and 50° for FB.

Fluid simulations were computed for 4 paired samples, and results are listed in Table 7. Eigenvalues were computed and the means of E2/E1 and E3/E1 were calculated, revealing a more uni-directional pronounced permeability in FB than in AB in 3 of the 4 paired samples. The inverse of the mean ratio EV for each sample was calculated to highlight the consistent scale of paired AB and FB (Table 7).

TABLE 7.

Results of fluid simulation for samples 54, 55, 56 and 57 showing the mean ratio of eigenvalues for each sample.

Sample Ratio EV mean Invert
54A 0.0037 273.4
54F 0.0024 425.5
55A 0.0768 13.0
55F 0.0171 58.5
56A 0.0162 61.7
56F 0.0338 29.6
57A 0.1509 6.6
57F 0.1237 8.1

Mean eigenvalues (with E1 > E2 > E3) of the permeability tensor and their ratio have already been computed. To illustrate, the invert number 273.4 means that the main permeability along the main permeability direction is 273.4 times more pronounced than it is in the orthogonal directions.

4 Discussion

This study examined patient-paired AB and FB at different length scales to quantify differences in bone morphology, including permeability properties, to comprehend factors that could be relevant to the success of microvascular free fibula bone transplants in reconstructive surgery. SR µ-CT evaluation of geometrical properties of human bone has been described before and used successfully (Hesse et al., 2014). However, to the best of our knowledge, a comparison of AB and FB on a micro scale in 3D has not been performed to date.

4.1 Lacunar density and morphology

Osteocyte lacunar properties in AB, tibial bone (TB) and femoral bone (FeB) have been described before, especially regarding either a variation in osteocyte lacunar density, volume, morphology, orientation or even age-dependent changes within a femur (Carter et al., 2013b; Ashique et al., 2017). In the present study, osteocyte lacunar density was found to be significantly higher in AB compared to FB. The high number of lacunae per mm3 found in AB, 20,228–24,108 (2.27 µm data set) and 20,978–28,416 (640 nm data set) are in accordance with previous SR µ-CT studies (Hesse et al., 2014a; Hesse et al., 2014b). Although various papers (Gauthier et al., 2018; Milovanovic and Busse, 2019) have addressed the question of inter-site variability of the osteocyte lacunar network, available data are still not fully conclusive.

Since the FB in our study was consequently standardized and harvested in the middle of diaphysis, no regional differences should occur due to different sampling locations. Gauthier et al. (2018), examined femoral diaphyses, femoral neck, and radial diaphyses and found a significantly higher lacunar density in the femoral neck compared to the radius (26,123/mm3 vs. 21,191/mm3). In contrast, the lacunar density of femoral diaphyses versus radial diaphyses showed merely slight differences (21,617/mm3 vs. 21,191/mm3) (Gauthier et al., 2018). These findings suggest that inter-site differences in one individual exist and that even anatomical regions near each other show differences in osteocyte lacunar number, which could suggest changes in bone microstructure between weight-bearing and non- or low-weight bearing areas (Gauthier et al., 2018; Milovanovic and Busse, 2019). The lacunar density of FB found in our study (17,882–21,873/mm3 for the 2.27 µm data set and 17,807–23,860/mm3 for the 640 nm data set) resembles the result for radial diaphyses as well as that for femoral diaphyses. Anatomically, radius and FB are comparable in terms of mechanical loading as both are low weight-bearing bones. We report that in 5 out of 6 scans, lacunar density was found to be higher for the 640 nm voxel-size data, suggesting that small lacunae were not identified when a large voxel setup was used. In only one sample does the 640 nm voxel-size data reveal a lower lacunar density, which might have originated from the heterogeneity within the individual sample. It must be noted that the analysed VOI of this particular sample was much smaller than that of the other samples. This implies that at 2.27 µm voxel-size of the used imaging setup and analysis, potentially undersegments about 5%–15% of the lacunae. Additionally, the shape of each lacuna was examined: the ratios of the lacunae principal axes lengths indicate a similar shape in the lacunae of AB and FB. The shape of the osteocyte lacunae and the potential influence on the function of osteocytes as a “mechanosensor” of the bone are assumed to be affected by mechanical loading of the bone (van Oers et al., 2015). Round osteocytes are considered to be more mechanosensitive compared to elongated osteocytes in long bones that are accustomed to high mechanical loadings (Bacabac et al., 2008). According to the assumption that variation in lacunar as well as osteocyte shape directly affects osteocytic mechanosensation and subsequently bone remodelling (van Oers et al., 2015), the findings of our study, which has a similar lacunar shape of AB and FB, might indicate comparable mechanosensitive properties. Wu et al. (2018), discovered significant differences in osteocyte surface area and orientation locally in the maxillary bone where the osteocyte surface area was 1.5 times higher and osteocyte-orientation was more cranially caudally orientated in tooth gaps compared to its orientation in edentulous parts of the maxilla, which may be related to tensile strain magnitude and orientation. Unfortunately, our data do not allow any conclusions to be drawn regarding local differences within an individual since only one AB and FB sample were examined per patient due to ethical and harvesting limitations. After transplantation, FB weight-bearing probably differs from its previous weight-bearing: dental implants are inserted when dental/prosthetic rehabilitation is done. Iezzi et al. (2020), found a higher number of osteocytes in the jawbone around immediately loaded implants compared to their number in unloaded bone sites, which suggests a change in bone matrix after dental implant loading. Changes in lacunar density of FB before and after dental implant insertion as well as after implant loading might be of particular interest. In addition, van Tol et al. (2020), showed that not only mechanical loading but also LCN architecture should be considered as a key determinant of bone adaption, which clears the way for further research. Given these preconditions, investigations of FB after dental implant insertion and weight-loading, due to prosthetic rehabilitation that affects this weight loading of the FB/neo-mandible, could help create an understanding of the process of adaption of the bone and the LCN to changes in mechanical loading.

4.2 Spatial mineral density distribution

In the present study, the mineral distance to the closest pore surface (considering 50% of all mineral volume) was found to be significantly higher in AB compared to FB, and the mineral distance (considering 95% of all mineral volume) tended to be higher in AB than in FB. Our study suggests that spatial mineral distribution is organized such that the distance to the closest vessel pore boundary is larger in AB than in FB. In contrast, AB shows a higher lacunar density than does FB, which might compensate for the great distance to the closest vessel. Recent studies have demonstrated the relation between LCN and mineralization (Roschger et al., 2019; Ayoubi et al., 2020), whereby a dense LCN is normally accompanied by a high degree of mineralization. The degree of mineralization could not be quantified in our study due to the different geometrics of the samples and the local-tomography imaging approach. The potential role of mineral exchange at the LCN interface has previously been reported in several researches (Qing et al., 2012; Kerschnitzki et al., 2013; Hesse et al., 2014a; Roschger et al., 2019).

4.3 Vessel network, porosity and permeability

The present results revealed an average vessel porosity (for the 2.27 µm samples) of 8.3% for AB and 6.9% for FB as well as 5.16% for AB and 5.61% for FB (for the 640 nm samples), which is consistent with the findings of previous studies (Feik et al., 1997; Bousson et al., 2000; Bousson et al., 2001; Kingsmill et al., 2007) and suggests similar characteristics in AB and FB. The average vascular porosity of different regions of the femur (midshaft, middiaphyseal, and midfemoral cortex) was found to be 7%–10% (Feik et al., 1997; Bousson et al., 2000; Bousson et al., 2001) and 3%–11% in the mandible (Kingsmill et al., 2007). Revascularization is described as the prime criterion for success in the regeneration of autologous bone grafts and transplants as well as for immobility and infection-free healing (Nelson et al., 2006). In order for a critical bone defect to heal, a newly formed bone requires a high vascularization (Lovett et al., 2009), which can be transferred to the osteotomy gap and the gap between FB and AB (as the recipient site). In maxillofacial surgery, the osteosynthesis normally needs to be removed (at least partially) prior to dental implant insertion (Kreutzer et al., 2022). Therefore, a sufficient osteogenesis with ossification of the osseous gap (FB and FB and AB and FB) is necessary. The rate of union in FFF is reported to be high (up to 97% after five years) (Houdek et al., 2017), which can be explained by the high number of vessels that follow the main axis of the graft and therefore allow a high blood supply leading to nutrient perfusion and mass transport. Additionally, in this area, the flow dynamic into the bone graft is often predefined by the recipient site/residual bone, where the orientation of the vessel network in FB might allow a high number of new vessel connections and a high number of vessels that can sprout into the osseous gap between AB and FB. The high and comparable number of vessels as well as the comparable vessel network between AB and FB may allow the FB graft to exhibit a high regeneration potential when connected to AB. This might correlate with a high osteoinductive and osteoconductive potential of FB when connected to AB, which is reflected in the similar distributions of vessel porosity.

Fluid simulation for most paired samples (three out of four) indicates a more pronounced relative permeability along the z-direction for FB compared to that in AB, which might correspond with the degree of osteoconductivity of FB. Unfortunately, only limited data on fluid flow simulation in patient-paired human bone samples exist (Rothweiler et al., 2022). Further studies on this simulation should be done, which could lead to an enhanced understanding of bone transplants if the composition of vessel pores and permeability becomes known. As aforementioned, a simplified approach with a single phase-flow was utilized (Rothweiler et al., 2022). This approach could be modified to create advanced models in subsequent studies.

A comparable SR µ-CT study (Rothweiler et al., 2022) to the current one focused on IC, which is an autologous bone graft known for its high clinical success in bone augmentation in oral and maxillofacial surgery (Nelson et al., 2006; Heberer et al., 2009; Fretwurst et al., 2015; Troeltzsch et al., 2016). Rothweiler et al. (2022), compared the bone morphology of AB (as a recipient/local bone) and IC. They found significantly more lacunae in AB compared to IC, which matches our findings for AB and FB. Moreover, AB showed a long distance for 50% and 95% of mineralized bone tissue to the closest vessel pore boundary (Rothweiler et al., 2022), which is in line with our results concerning mineral distance. This allows speculation that an increased number of osteocyte lacunae might compensate for the high average distance of the mineralized bone tissue to the nearest vessel in AB. Regarding the two different bone sites, IC and FB, AB evidently features different bone morphological characteristics that must be considered in designing 3D scaffolds for the maxilla and especially the mandible.

4.4 Limitations

The major limitation of this study is that only eight patients were included in this study, whereby samples of four patients were scanned at 2.27 µm and samples of seven patients were scanned at 640 nm voxel-size (including three patients from the 2.27 µm setup). Additionally, the samples of AB were not taken from identical regions of the mandible and one AB sample was taken from the maxilla. The segmentation of the lacunae is sensitive to the quality of the reconstructed SR µ-CT data. In turn, image quality can be a function of sample size, which also varied in different scans. Segmentation routines that are automatically adapted for each individual lacuna should be implemented for future studies. Additionally, the used voxel-size and the actual resolution must not be confused, since the resolution depends not only on the voxel-size but also on factors such as the Signal-to-Noise Ratio.

5 Conclusion

Vessel porosity, vessel network, vessel distance, as well as lacunar volume were not significantly different between AB and FB. Significant differences could be found for lacunar density and the average mineral-pore distance. Similarities in vessel orientation, porosity and vessel network might be beneficial to the osseous union of FFF and the jaw in reconstructive oral and maxillofacial surgeries. If differing lacunar density and average mineral-pore distance adversely affect the success of a bone graft/transplant, further research should be done. Additional studies on possible changes in a recipient site and the bone graft/transplant itself with regard to possible adaption mechanisms might help to create an understanding of how FB or AB contributes to the success of a transplant.

Acknowledgments

All authors thank the Synchrotron Soleil, Paris, France for the allocated beamtime at the PSICHÉ beamline as well as ESRF in Grenoble, France for the allocated beamtime at the ID 19 beamline.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.

Ethics statement

The studies involving human participants were reviewed and approved by the Ethics Committee of the Faculty of Medicine Charité Berlin (EA4/161/18). The patients/participants provided their written informed consent to participate in this study.

Author contributions

JW: conceptualization, investigation, resources, data curation, writing—original draft, visualization, and project administration. BH: supervision, methodology, validation, investigation, resources, data curation, visualization, software, and writing—original draft. RR: investigation, data curation, conceptualization, and writing—original draft. EmB: methodology, validation, investigation, resources, data curation, software, and writing—review and editing. CG: writing—review and editing. SB: methodology, software, and writing—review and editing. AK: methodology and investigation. ElB: methodology and investigation. JG: methodology, visualization, software, and writing—review and editing. CR: writing—review and editing. TF: conceptualization and writing—review and editing. SP: writing—review and editing. MH: resources, validation, supervision, conceptualization, and writing—review and editing. KN: resources, investigations, supervision, conceptualization, and writing—review and editing. SN: project administration, supervision, conceptualization, funding acquisition, and writing—original draft. All authors contributed to the article and approved the submitted version.

Conflict of interest

EmB, SB, JG, and BH were employed by Xploraytion GmbH.

The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fbioe.2023.1169385/full#supplementary-material

SUPPLEMENTARY FIGURE S1

For each sample of the 2.27 µm voxel-size setup (54–57 A and F), SR-µCT images from all 3 angles (YZ; XZ:XY), the VOI, and a 3D rendering are listed. The corresponding scalebar is provided within each figure. A indicates alveoalar bone, and F fibula bone.

SUPPLEMENTARY FIGURE S2

For each sample of the 640 nm voxel-size setup (54–56 A and F, respectively 63, 67-69 A and F), SR-µCT images from all 3 angles (YZ; XZ:XY), as well as the VOI are listed. The corresponding scalebar is provided within each figure. A indicates alveoalar bone, and F fibula bone.

SUPPLEMENTARY FIGURE S3

Scatterplot showing the relation between Lacunar Density per mm3 (x-axis) and Mineral Distance (95%) y-axis for AB and FB samples 54–57. Blue indicates AB, orange represents FB.

Abbreviations

3D, three-dimensional; AB, alveolar bone; BV, bone volume; CAD/CAM, critical-sized and/or complex bone; CSBD, critical-sized bone defect; CT, computed tomography; IC, iliac crest; IPS, intracortical pore system; LCN, osteocyte lacunar–canalicular system; LOA, level of alignment; N.Lc, number of lacunae; SA, surface area; SR µ-CT, synchrotron radiation micro-computed tomography; Tb.Sp, trabecular separation; Tb.Th, trabecular thickness; TV, total volume; VXL, voxel; VOI, volume of interest.

References

  1. Ashique A. M., Hart L. S., Thomas C. D. L., Clement J. G., Pivonka P., Carter Y., et al. (2017). Lacunar-canalicular network in femoral cortical bone is reduced in aged women and is predominantly due to a loss of canalicular porosity. Bone Rep. 7, 9–16. 10.1016/j.bonr.2017.06.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Ayoubi M., van Tol A. F., Weinkamer R., Roschger P., Brugger P. C., Berzlanovich A., et al. (2020). Three-dimensional interrelationship between osteocyte network and forming mineral during human bone remodeling. bioRxiv.2011.2020. 391862. 10.1101/2020.11.20.391862 [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Bacabac R. G., Mizuno D., Schmidt C. F., MacKintosh F. C., Van Loon J. J., Klein-Nulend J., et al. (2008). Round versus flat: bone cell morphology, elasticity, and mechanosensing. J. Biomech. 41 (7), 1590–1598. 10.1016/j.jbiomech.2008.01.031 [DOI] [PubMed] [Google Scholar]
  4. Blumberg J. M., Walker P., Johnson S., Johnson B., Yu E., Lacasse M. C., et al. (2019). Mandibular reconstruction with the scapula tip free flap. Head. Neck 41 (7), 2353–2358. 10.1002/hed.25702 [DOI] [PubMed] [Google Scholar]
  5. Bortel E., Grover L. M., Eisenstein N., Seim C., Suhonen H., Pacureanu A., et al. (2022). Interconnectivity explains high canalicular network robustness between neighboring osteocyte lacunae in human bone. Adv. NanoBiomed Res. 2 (4), 2100090. 10.1002/anbr.202100090 [DOI] [Google Scholar]
  6. Bousson V., Bergot C., Meunier A., Barbot F., Parlier-Cuau C., Laval-Jeantet A.-M., et al. (2000). CT of the middiaphyseal femur: cortical bone mineral density and relation to porosity. Radiology 217 (1), 179–187. 10.1148/radiology.217.1.r00se11179 [DOI] [PubMed] [Google Scholar]
  7. Bousson V., Meunier A., Bergot C., Vicaut É., Rocha M. A., Morais M. H., et al. (2001). Distribution of intracortical porosity in human midfemoral cortex by age and gender. J. Bone Min. Res. 16 (7), 1308–1317. 10.1359/jbmr.2001.16.7.1308 [DOI] [PubMed] [Google Scholar]
  8. Bouxsein M. L., Boyd S. K., Christiansen B. A., Guldberg R. E., Jepsen K. J., Müller R. (2010). Guidelines for assessment of bone microstructure in rodents using micro-computed tomography. J. Bone Min. Res. 25 (7), 1468–1486. 10.1002/jbmr.141 [DOI] [PubMed] [Google Scholar]
  9. Burger E. H., Klein-Nulend J. (1999). Mechanotransduction in bone—Role of the lacunocanalicular network. FASEB J. 13 (9001), S101–S112. 10.1096/fasebj.13.9001.s101 [DOI] [PubMed] [Google Scholar]
  10. Carter Y., Thomas C. D. L., Clement J. G., Cooper D. M. L. (2013a). Femoral osteocyte lacunar density, volume and morphology in women across the lifespan. J. Struct. Biol. 183 (3), 519–526. 10.1016/j.jsb.2013.07.004 [DOI] [PubMed] [Google Scholar]
  11. Carter Y., Thomas C. D. L., Clement J. G., Peele A. G., Hannah K., Cooper D. M. L. (2013b). Variation in osteocyte lacunar morphology and density in the human femur — A synchrotron radiation micro-CT study. Bone 52 (1), 126–132. 10.1016/j.bone.2012.09.010 [DOI] [PubMed] [Google Scholar]
  12. Chaine A., Pitak-Arnnop P., Hivelin M., Dhanuthai K., Bertrand J. C., Bertolus C. (2009). Postoperative complications of fibular free flaps in mandibular reconstruction: an analysis of 25 consecutive cases. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. 108 (4), 488–495. 10.1016/j.tripleo.2009.05.043 [DOI] [PubMed] [Google Scholar]
  13. Chen J., Hendriks M., Chatzis A., Ramasamy S. K., Kusumbe A. P. (2020). Bone vasculature and bone marrow vascular niches in health and disease. J. Bone Min. Res. 35 (11), 2103–2120. 10.1002/jbmr.4171 [DOI] [PubMed] [Google Scholar]
  14. Currey J. D. (2014). New Jersey: Princeton University Press. [Google Scholar]
  15. Dempster D. W., Compston J. E., Drezner M. K., Glorieux F. H., Kanis J. A., Malluche H., et al. (2013). Standardized nomenclature, symbols, and units for bone histomorphometry: a 2012 update of the report of the asbmr histomorphometry nomenclature committee. J. Bone Mineral Res. 28 (1), 2–17. 10.1002/jbmr.1805 [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Dong P., Haupert S., Hesse B., Langer M., Gouttenoire P. J., Bousson V., et al. (2014). 3D osteocyte lacunar morphometric properties and distributions in human femoral cortical bone using synchrotron radiation micro-CT images. Bone 60, 172–185. 10.1016/j.bone.2013.12.008 [DOI] [PubMed] [Google Scholar]
  17. Feik S., Thomas C., Clement J. (1997). Age-related changes in cortical porosity of the midshaft of the human femur. J. Anat. 191 (3), 407–416. 10.1046/j.1469-7580.1997.19130407.x [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Fliss E., Yanko R., Bracha G., Teman R., Amir A., Horowitz G., et al. (2021). The evolution of the free fibula flap for head and neck reconstruction: 21 Years of experience with 128 flaps. J. Reconstr. Microsurg 37 (4), 372–379. 10.1055/s-0040-1717101 [DOI] [PubMed] [Google Scholar]
  19. Fretwurst T., Gad L. M., Nelson K., Schmelzeisen R. (2015). Dentoalveolar reconstruction: modern approaches. Curr. Opin. Otolaryngol. Head. Neck Surg. 23 (4), 316–322. 10.1097/moo.0000000000000167 [DOI] [PubMed] [Google Scholar]
  20. Fretwurst T., Tritschler I., Rothweiler R., Nahles S., Altmann B., Schilling O., et al. (2022). Proteomic profiling of human bone from different anatomical sites - a pilot study. Proteomics Clin. Appl. 16 (5), e2100049. 10.1002/prca.202100049 [DOI] [PubMed] [Google Scholar]
  21. Gauthier R., Langer M., Follet H., Olivier C., Gouttenoire P. J., Helfen L., et al. (2018). 3D micro structural analysis of human cortical bone in paired femoral diaphysis, femoral neck and radial diaphysis. J. Struct. Biol. 204 (2), 182–190. 10.1016/j.jsb.2018.08.006 [DOI] [PubMed] [Google Scholar]
  22. Gonçalves R. C., Banfi A., Oliveira M. B., Mano J. F. (2021). Strategies for re-vascularization and promotion of angiogenesis in trauma and disease. Biomaterials 269, 120628. 10.1016/j.biomaterials.2020.120628 [DOI] [PubMed] [Google Scholar]
  23. Heberer S., Rühe B., Krekeler L., Schink T., Nelson J. J., Nelson K. (2009). A prospective randomized split-mouth study comparing iliac onlay grafts in atrophied edentulous patients: covered with periosteum or a bioresorbable membrane. Clin. Oral Implants Res. 20 (3), 319–326. 10.1111/j.1600-0501.2008.01638.x [DOI] [PubMed] [Google Scholar]
  24. Hesse B., Männicke N., Pacureanu A., Varga P., Langer M., Maurer P., et al. (2014a). Accessing osteocyte lacunar geometrical properties in human jaw bone on the submicron length scale using synchrotron radiation μCT. J. Microsc. 255 (3), 158–168. 10.1111/jmi.12147 [DOI] [PubMed] [Google Scholar]
  25. Hesse B., Langer M., Varga P. (2014b). Alterations of mass density and 3D osteocyte lacunar properties in bisphosphonate-related osteonecrotic human jaw bone, a synchrotron 󠂵CT study. PLoS One. 9 (2), e88481. 10.1371/journal.pone.0088481 [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Hesse B., Varga P., Langer M., Pacureanu A., Schrof S., Männicke N., et al. (2015). Canalicular network morphology is the major determinant of the spatial distribution of mass density in human bone tissue: evidence by means of synchrotron radiation phase-contrast nano-CT. J. Bone Min. Res. 30 (2), 346–356. 10.1002/jbmr.2324 [DOI] [PubMed] [Google Scholar]
  27. Houdek M. T., Bayne C. O., Bishop A. T., Shin A. Y. (2017). The outcome and complications of vascularised fibular grafts. Bone Jt. J. 99-b (1), 134–138. 10.1302/0301-620x.99b1.Bjj-2016-0160.R1 [DOI] [PubMed] [Google Scholar]
  28. Iezzi G., Mangano C., Barone A., Tirone F., Baggi L., Tromba G., et al. (2020). Jawbone remodeling: a conceptual study based on synchrotron high-resolution tomography. Sci. Rep. 10 (1), 3777. 10.1038/s41598-020-60718-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. Keating J. F., Simpson A. H., Robinson C. M. (2005). The management of fractures with bone loss. J. Bone Jt. Surg. Br. 87 (2), 142–150. 10.1302/0301-620x.87b2.15874 [DOI] [PubMed] [Google Scholar]
  30. Kerschnitzki M., Kollmannsberger P., Burghammer M., Duda G. N., Weinkamer R., Wagermaier W., et al. (2013). Architecture of the osteocyte network correlates with bone material quality. J. Bone Min. Res. 28 (8), 1837–1845. 10.1002/jbmr.1927 [DOI] [PubMed] [Google Scholar]
  31. Kingsmill V., Gray C., Moles D., Boyde A. (2007). Cortical vascular canals in human mandible and other bones. J. Dent. Res. 86 (4), 368–372. 10.1177/154405910708600413 [DOI] [PubMed] [Google Scholar]
  32. Knitschke M., Yonan M., Roller F. C., Pons-Kühnemann J., Attia S., Howaldt H.-P., et al. (2022). Osseous union after jaw reconstruction with fibula-free flap: conventional vs. CAD/CAM patient-specific implants. Cancers 14 (23), 5774. 10.3390/cancers14235774 [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Kreutzer K., Steffen C., Nahles S., Koerdt S., Heiland M., Rendenbach C., et al. (2022). Removal of patient-specific reconstruction plates after mandible reconstruction with a fibula free flap: is the plate the problem? Int. J. Oral Maxillofac. Surg. 51 (2), 182–190. 10.1016/j.ijom.2021.04.003 [DOI] [PubMed] [Google Scholar]
  34. Kulzer (2012). Polymerisation systems for histological applications [online]. Kulzer GmbH. Available at: https://www.kulzer-technik.de/media/webmedia_local/kulzer_technique/media_4/histologie_1/Prospekt_Histologie_englisch.pdf.
  35. Ling X. F., Peng X. (2012). What is the price to pay for a free fibula flap? A systematic review of donor-site morbidity following free fibula flap surgery. Plast. Reconstr. Surg. 129 (3), 657–674. 10.1097/PRS.0b013e3182402d9a [DOI] [PubMed] [Google Scholar]
  36. López-Arcas J. M., Arias J., Del Castillo J. L., Miguel Burgueño M., Navarro I., Morán M. J., et al. (2010). The fibula osteomyocutaneous flap for mandible reconstruction: a 15-year experience. J. Oral Maxillofac. Surg. 68 (10), 2377–84. 10.1016/j.joms.2009.09.027 [DOI] [PubMed] [Google Scholar]
  37. Lovett M., Lee K., Edwards A., Kaplan D. L. (2009). Vascularization strategies for tissue engineering. Tissue Eng. Part B Rev. 15 (3), 353–370. 10.1089/ten.TEB.2009.0085 [DOI] [PMC free article] [PubMed] [Google Scholar]
  38. Ma J. L., Pan J. L., Tan B. S., Cui F. Z. (2009). Determination of critical size defect of minipig mandible. J. Tissue Eng. Regen. Med. 3 (8), 615–622. 10.1002/term.203 [DOI] [PubMed] [Google Scholar]
  39. Mahendru S., Jain R., Aggarwal A., Aulakh H. S., Jain A., Khazanchi R. K., et al. (2020). CAD-CAM vs conventional technique for mandibular reconstruction with free fibula flap: a comparison of outcomes. Surg. Oncol. 34, 284–291. 10.1016/j.suronc.2020.04.012 [DOI] [PubMed] [Google Scholar]
  40. Milovanovic P., Busse B. (2019). Inter-site variability of the human osteocyte lacunar network: implications for bone quality. Curr. Osteoporos. Rep. 17 (3), 105–115. 10.1007/s11914-019-00508-y [DOI] [PubMed] [Google Scholar]
  41. Nelson K., Ozyuvaci H., Bilgic B., Klein M., Hildebrand D. (2006). Histomorphometric evaluation and clinical assessment of endosseous implants in iliac bone grafts with shortened healing periods. Int. J. Oral Maxillofac. Implants 21 (3), 392–398. [PubMed] [Google Scholar]
  42. Paganin D., Mayo S. C., Gureyev T. E., Miller P. R., Wilkins S. W. (2002). Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object. J. Microsc. 206 (Pt 1), 33–40. 10.1046/j.1365-2818.2002.01010.x [DOI] [PubMed] [Google Scholar]
  43. Pearce A. I., Richards R. G., Milz S., Schneider E., Pearce S. G. (2007). Animal models for implant biomaterial research in bone: a review. Eur. Cell. Mater 13, 1–10. 10.22203/ecm.v013a01 [DOI] [PubMed] [Google Scholar]
  44. Portier H. J., Kewish C. M., Chappard C., Pallu S. (2020). New insights in osteocyte imaging by synchrotron radiation. J. Spectr. Imaging 9. 10.1255/jsi.2020.a3 [DOI] [Google Scholar]
  45. Qing H., Ardeshirpour L., Pajevic P. D., Dusevich V., Jähn K., Kato S., et al. (2012). Demonstration of osteocytic perilacunar/canalicular remodeling in mice during lactation. J. Bone Min. Res. 27 (5), 1018–1029. 10.1002/jbmr.1567 [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Qu M., Wang C., Zhou X., Libanori A., Jiang X., Xu W., et al. (2021). Multi-dimensional printing for bone tissue engineering. Adv. Healthc. Mater 10 (11), e2001986. 10.1002/adhm.202001986 [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Roschger A., Roschger P., Wagermaier W., Chen J., van Tol A. F., Repp F., et al. (2019). The contribution of the pericanalicular matrix to mineral content in human osteonal bone. Bone 123, 76–85. 10.1016/j.bone.2019.03.018 [DOI] [PubMed] [Google Scholar]
  48. Rosen E. B., Kyle Gazdeck R., Goldman D. A., Panchal H., Jones E., Nguyen J. P., et al. (2022). An anatomic analysis of fibula flap mandible reconstructions: implications for endosseous implant placement. Plast. Reconstr. Surg. 149 (6), 1419–1428. 10.1097/prs.0000000000009152 [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Rothweiler R., Gross C., Bortel E., Früh S., Gerber J., Boller E., et al. (2022). Comparison of the 3D-microstructure between alveolar and iliac bone for enhanced bioinspired bone graft substitutes. Front. Bioeng. Biotechnol. 10, 862395. 10.3389/fbioe.2022.862395 [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Sanders D. W., Bhandari M., Guyatt G., Heels-Ansdell D., Schemitsch E. H., Swiontkowski M., et al. (2014). Critical-sized defect in the tibia: is it critical? Results from the SPRINT trial. J. Orthop. Trauma 28 (11), 632–635. 10.1097/bot.0000000000000194 [DOI] [PubMed] [Google Scholar]
  51. Schneider P., Meier M., Wepf R., Müller R. (2010). Towards quantitative 3D imaging of the osteocyte lacuno-canalicular network. Bone 47 (5), 848–858. 10.1016/j.bone.2010.07.026 [DOI] [PubMed] [Google Scholar]
  52. Sharma D., Ross D., Wang G., Jia W., Kirkpatrick S. J., Zhao F. (2019). Upgrading prevascularization in tissue engineering: a review of strategies for promoting highly organized microvascular network formation. Acta Biomater. 95, 112–130. 10.1016/j.actbio.2019.03.016 [DOI] [PubMed] [Google Scholar]
  53. Troeltzsch M., Troeltzsch M., Kauffmann P., Gruber R., Brockmeyer P., Moser N., et al. (2016). Clinical efficacy of grafting materials in alveolar ridge augmentation: a systematic review. J. Craniomaxillofac Surg. 44 (10), 1618–1629. 10.1016/j.jcms.2016.07.028 [DOI] [PubMed] [Google Scholar]
  54. van Oers R. F., Wang H., Bacabac R. G. (2015). Osteocyte shape and mechanical loading. Curr. Osteoporos. Rep. 13 (2), 61–66. 10.1007/s11914-015-0256-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  55. van Tol A. F., Schemenz V., Wagermaier W., Roschger A., Razi H., Vitienes I., et al. (2020). The mechanoresponse of bone is closely related to the osteocyte lacunocanalicular network architecture. Proc. Natl. Acad. Sci. 117(51), 32251–32259. 10.1073/pnas.2011504117 [DOI] [PMC free article] [PubMed] [Google Scholar]
  56. Vatsa A., Breuls R. G., Semeins C. M., Salmon P. L., Smit T. H., Klein-Nulend J. (2008). Osteocyte morphology in fibula and calvaria --- is there a role for mechanosensing? Bone 43 (3), 452–458. 10.1016/j.bone.2008.01.030 [DOI] [PubMed] [Google Scholar]
  57. Verhelst P. J., Dons F., Van Bever P. J., Schoenaers J., Nanhekhan L., Politis C. (2019). Fibula free flap in head and neck reconstruction: identifying risk factors for flap failure and analysis of postoperative complications in a low volume setting. Craniomaxillofac Trauma Reconstr. 12 (3), 183–192. 10.1055/s-0038-1651515 [DOI] [PMC free article] [PubMed] [Google Scholar]
  58. Vidal L., Kampleitner C., Brennan M. Á., Hoornaert A., Layrolle P. (2020). Reconstruction of large skeletal defects: current clinical therapeutic strategies and future directions using 3D printing. Front. Bioeng. Biotechnol. 8, 61. 10.3389/fbioe.2020.00061 [DOI] [PMC free article] [PubMed] [Google Scholar]
  59. Weber F. E. (2019). Reconsidering osteoconduction in the era of additive manufacturing. Tissue Eng. Part B Rev. 25 (5), 375–386. 10.1089/ten.TEB.2019.0047 [DOI] [PMC free article] [PubMed] [Google Scholar]
  60. Whitaker S. (1999). The method of volume averaging. Netherlands: Kluwer Academic Publishers. [Google Scholar]
  61. Wu V., van Oers R. F. M., Schulten E., Helder M. N., Bacabac R. G., Klein-Nulend J. (2018). Osteocyte morphology and orientation in relation to strain in the jaw bone. Int. J. Oral Sci. 10 (1), 2. 10.1038/s41368-017-0007-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  62. Zimmermann C., Börner B., Hasse A., Sieg P. (2002). Donor site morbidity after microvascular fibula transfer. Clin. oral Investig. 5, 214–219. 10.1007/s00784-001-0140-5 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

SUPPLEMENTARY FIGURE S1

For each sample of the 2.27 µm voxel-size setup (54–57 A and F), SR-µCT images from all 3 angles (YZ; XZ:XY), the VOI, and a 3D rendering are listed. The corresponding scalebar is provided within each figure. A indicates alveoalar bone, and F fibula bone.

SUPPLEMENTARY FIGURE S2

For each sample of the 640 nm voxel-size setup (54–56 A and F, respectively 63, 67-69 A and F), SR-µCT images from all 3 angles (YZ; XZ:XY), as well as the VOI are listed. The corresponding scalebar is provided within each figure. A indicates alveoalar bone, and F fibula bone.

SUPPLEMENTARY FIGURE S3

Scatterplot showing the relation between Lacunar Density per mm3 (x-axis) and Mineral Distance (95%) y-axis for AB and FB samples 54–57. Blue indicates AB, orange represents FB.

Data Availability Statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.


Articles from Frontiers in Bioengineering and Biotechnology are provided here courtesy of Frontiers Media SA

RESOURCES