Flexible ureteroscopy (fURS) with laser lithotripsy is currently the gold standard surgical treatment for ureteral and kidney stones with a maximum diameter of 2 cm [1]. For nearly 25 years, low-power (LP) Holmium:YAG (Ho:YAG) laser has been the technology of reference in this field to achieve satisfactory outcomes in terms of safety and efficacy for all types of stones [2]. While LP Ho:YAG laser generators have demonstrated acceptable intraoperative and postoperative complication rates and stone-free rates (SFR), this technology still has certain limitations, especially regarding lithotripsy efficiency (measured in J/mm3) and lithotripsy speed (mm3/s). The need to overcome the limitations of LP Ho:YAG laser lithotripsy has prompted major technological advancements in the field of laser technology for endoscopic lithotripsy. The introduction of high-power (HP) Ho:YAG laser generators up to 150 W, the implementation of pulse modulation for the Ho:YAG laser beam, and the marketing of both thulium fiber laser (TFL) and pulsated Tm:YAG laser generators have dramatically increased the number of available options. However, these novelties have not always been supported by an adequate level of scientific evidence, especially in real-life clinical scenarios. Several pre-clinical studies have shown the potential advantages of these new laser technologies for endoscopic lithotripsy, but there is an absence of consistent in vivo evidence.
As opposed to LP Ho:YAG laser generators, HP variants may achieve high frequencies, reaching up to 120 Hz, thus leading to potentially faster stone ablation. This has important implications in terms of the choice of parameters, lithotripsy technique, and perioperative outcomes [3]. A recent systematic review reported that HP Ho:YAG laser lithotripsy had a shorter mean operative time compared to LP; however, no significant differences were found in terms of surgical complications and SFR. Do we have enough evidence to draw conclusions on this matter? Considering the aforementioned report, only one non-randomized comparative study was available, and the remaining studies were single-arm case series; therefore, there was a relevant risk of bias in the pooled estimate [4]. In a randomized controlled trial comparing LP and HP Ho:YAG laser settings during ureteroscopic laser lithotripsy, Shrestha and colleagues found that HP lithotripsy did not significantly increase lithotripsy speed, whereas it delivered more energy compared to LP lithotripsy for treating an equal amount of stone volume (higher J/mm3) [5].
In addition to the implementation of HP lithotripsy, does pulse modulation play a significant role as well? Despite the possibility of configuring the laser for both short and long pulse modalities for stone fragmentation and dusting lithotripsy technique [6], the Moses TechnologyTM (MT, Boston Scientific, Marlborough, MA, USA) made its entrance into the endourological armamentarium in 2017. Several other similar options, such as Virtual BasketTM (Quanta System, Samarate, Italy), Advanced ModeTM (Dornier MedTech, Munich, Germany), and Stabilization ModeTM (Olympus, Shinjuku, Tokyo, Japan), were later developed. The underlying idea is to split a single laser pulse into two sub-pulses with different peak power. The first sub-pulse generates a vapor bubble in the fluid medium, enabling a second sub-pulse to reach the target without dissipating its energy in the medium, thereby maximizing the effect on the target and reducing stone retropulsion [7]. However, despite the appealing concept and promising pre-clinical laboratory results, this technology is not yet solidly supported by high-level clinical evidence [8]. Moreover, MT effects in terms of lithotripsy efficiency share similar characteristics with low-peak power Ho:YAG laser pulses [9]. Similar conclusions were reported in a recent systematic review conducted by Corrales et al., including studies on the more recently launched MT 2.0 [10]. There is still conflicting evidence regarding pulse-modulated Ho:YAG lithotripsy: a recent retrospective comparative study conducted in a high-volume proficient endourological centre found that the use of HP Ho:YAG laser with MT was significantly faster for stone lithotripsy and reduced both operative time and the need for a second procedure compared to LP Ho:YAG laser [11].
The latest innovation in the field of endoscopic laser lithotripsy is represented by TFL, which is rapidly spreading worldwide as an excellent alternative to the Ho:YAG laser. This laser technology largely differs from Ho:YAG laser in several physical and technical aspects [12]. Briefly, with TFL, it is possible to obtain the following: (i) a wider possibility of laser setting with potential very low energies (0.025 J) and high frequencies (2000 Hz); (ii) the use of thinner laser fibers and thus better endoscope deflection and irrigation, (iii) less stone retropulsion; (iv) higher ablation speed for any stone composition, which is two to five times faster than Ho:YAG even with MT; (v) thinner dust particles; and (vi) higher postoperative stone-free rate [12,13]. However, most of the evidence regarding the advantages of TFL over Ho:YAG stems from pre-clinical studies, and the clinical benefits in real-life scenarios are still debated and controversial [13,14,15,16].
Overall, despite the improvement in available technologies for endoscopic laser lithotripsy and the broader field of endourology [17], there is a need for robust clinical data that will eventually support clinical decision making.
Furthermore, when treating stone disease, it is important to remember that there is much more that we can do beyond properly using the available technology. For instance, adequate knowledge of the biology of lithogenesis and the possible measures aimed at improving the management of patients with stone disease significantly improves the clinical outcomes of patients [18].
In conclusion, a surge of technological innovations and improvements has recently occurred in the field of endoscopic laser lithotripsy. However, clinical evidence regarding the benefits in terms of surgical outcomes in real-life scenarios is still lacking, as most of the available results originate from pre-clinical studies. Beyond the importance of technology, we emphasize the importance of patient metabolic assessment in the pursuit of obtaining and maintaining a stone-free status.
Author Contributions
Conceptualization, L.C. and E.V.; methodology E.V.; validation, E.X.K., A.P., F.E., P.J.-J., E.E., V.D.C., T.T., M.T., S.T., E.T.S., B.M.Z.H., L.T., I.M., A.T. and A.S.; writing—original draft preparation, L.C.; writing—review and editing, E.V. and A.S.; visualization, E.X.K., A.P., F.E., P.J.-J., E.E., V.D.C., T.T., M.T., S.T., E.T.S., B.M.Z.H., L.T., I.M. and A.T.; supervision, E.X.K., A.P. and A.S. All authors have read and agreed to the published version of the manuscript.
Conflicts of Interest
The authors declare no conflict of interest.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
References
- 1.Skolarikos A., Jung H., Neisius A., Petřík A., Somani B., Tailly T., Gambaro G. EAU Guidelines on Urolithiasis 2023. EAU Annual Congress; Milan, Italy: 2023. [Google Scholar]
- 2.De Coninck V., Hente R., Claessens M., Duchateau A., Doizi S., Keller E.X. High-power, High-frequency Ho:YAG Lasers Are Not Essential for Retrograde Intrarenal Surgery. Eur. Urol. Focus. 2021;7:5–6. doi: 10.1016/j.euf.2020.12.007. [DOI] [PubMed] [Google Scholar]
- 3.Chen J., Li D., Yu W., Ma Z., Li C., Xiang G., Wu Y., Yao J., Zhong P. The Effects of Scanning Speed and Standoff Distance of the Fiber on Dusting Efficiency during Short Pulse Holmium: YAG Laser Lithotripsy. J. Clin. Med. 2022;11:5048. doi: 10.3390/jcm11175048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Ventimiglia E., Pauchard F., Quadrini F., Sindhubodee S., Kamkoum H., Godínez A.J., Doizi S., Traxer O. High- and Low-Power Laser Lithotripsy Achieves Similar Results: A Systematic Review and Meta-Analysis of Available Clinical Series. J. Endourol. 2021;35:1146–1152. doi: 10.1089/end.2020.0090. [DOI] [PubMed] [Google Scholar]
- 5.Shrestha A., Corrales M., Adhikari B., Chapagain A., Traxer O. Comparison of low power and high power holmium YAG laser settings in flexible ureteroscopy. World J. Urol. 2022;40:1839–1844. doi: 10.1007/s00345-022-04040-0. [DOI] [PubMed] [Google Scholar]
- 6.Uzan A., Chiron P., Panthier F., Haddad M., Berthe L., Traxer O., Doizi S. Comparison of Holmium:YAG and Thulium Fiber Lasers on the Risk of Laser Fiber Fracture. J. Clin. Med. 2021;10:2960. doi: 10.3390/jcm10132960. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Sánchez-Puy A., Bravo-Balado A., Diana P., Baboudjian M., Piana A., Girón I., Kanashiro A.K., Angerri O., Contreras P., Eisner B.H., et al. New Generation Pulse Modulation in Holmium:YAG Lasers: A Systematic Review of the Literature and Meta-Analysis. J. Clin. Med. 2022;11:3208. doi: 10.3390/jcm11113208. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Ventimiglia E., Traxer O. What Is Moses Effect: A Historical Perspective. J. Endourol. 2019;33:353–357. doi: 10.1089/end.2019.0012. [DOI] [PubMed] [Google Scholar]
- 9.Corsini C., de Angelis M., Villa L., Somani B.K., Pietropaolo A., Montorsi F., Goumas I.K., Traxer O., Salonia A., Ventimiglia E. Holmium: Yttrium-aluminum-garnet laser with Moses: Does it make a difference? Curr. Opin. Urol. 2022;32:324–329. doi: 10.1097/MOU.0000000000000979. [DOI] [PubMed] [Google Scholar]
- 10.Corrales M., Sierra A., Traxer O. Moses and Moses 2.0 for Laser Lithotripsy: Expectations vs. Reality. J. Clin. Med. 2022;11:4828. doi: 10.3390/jcm11164828. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Pietropaolo A., Hughes T., Mani M., Somani B. Outcomes of Ureteroscopy and Laser Stone Fragmentation (URSL) for Kidney Stone Disease (KSD): Comparative Cohort Study Using MOSES Technology 60 W Laser System versus Regular Holmium 20 W Laser. J. Clin. Med. 2021;10:2742. doi: 10.3390/jcm10132742. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Traxer O., Keller E.X. Thulium fiber laser: The new player for kidney stone treatment? A comparison with Holmium:YAG laser. World J. Urol. 2019;38:1883–1894. doi: 10.1007/s00345-019-02654-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Traxer O., Corrales M. Managing Urolithiasis with Thulium Fiber Laser: Updated Real-Life Results—A Systematic Review. J. Clin. Med. 2021;10:3390. doi: 10.3390/jcm10153390. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Sierra A., Corrales M., Somani B., Traxer O. Laser Efficiency and Laser Safety: Holmium YAG vs. Thulium Fiber Laser. J. Clin. Med. 2022;12:149. doi: 10.3390/jcm12010149. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Ventimiglia E., Corsini C., Fantin M., Traxer O., Salonia A. Clinical comparison of thulium fiber and holmium: Yttrium-aluminum-garnet lasers for the treatment of upper urinary tract stone disease: Are we doing it right? Minerva Urol. Nephrol. 2022;74:502–503. doi: 10.23736/S2724-6051.22.05006-6. [DOI] [PubMed] [Google Scholar]
- 16.Ventimiglia E., Doizi S., Kovalenko A., Andreeva V., Traxer O. Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers. BJU Int. 2020;126:159–167. doi: 10.1111/bju.15079. [DOI] [PubMed] [Google Scholar]
- 17.De Lorenzis E., Zanetti S.P., Boeri L., Montanari E. Is There Still a Place for Percutaneous Nephrolithotomy in Current Times? J. Clin. Med. 2022;11:5157. doi: 10.3390/jcm11175157. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Dai J.C., Pearle M.S. Diet and Stone Disease in 2022. J. Clin. Med. 2022;11:4740. doi: 10.3390/jcm11164740. [DOI] [PMC free article] [PubMed] [Google Scholar]