Spinal manipulation characteristics: a scoping literature review of force-time characteristics

Lindsay M Gorrell 1,, Luana Nyirö 1, Mégane Pasquier 2,3, Isabelle Pagé 4,5, Nicola R Heneghan 6, Petra Schweinhardt 1, Martin Descarreaux 3,7
PMCID: PMC10500795  PMID: 37705030

Abstract

Background

Spinal manipulation (SM) is a recommended and effective treatment for musculoskeletal disorders. Biomechanical (kinetic) parameters (e.g. preload/peak force, rate of force application and thrust duration) can be measured during SM, quantifying the intervention. Understanding these force-time characteristics is the first step towards identifying possible active ingredient/s responsible for the clinical effectiveness of SM. Few studies have quantified SM force-time characteristics and with considerable heterogeneity evident, interpretation of findings is difficult. The aim of this study was to synthesise the literature describing force-time characteristics of manual SM.

Methods

This scoping literature review is reported following the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) statement. Databases were searched from inception to October 2022: MEDLINE (Ovid), Embase, CINAHL, ICL, PEDro and Cochrane Library. The following search terms and their derivatives were adapted for each platform: spine, spinal, manipulation, mobilization or mobilisation, musculoskeletal, chiropractic, osteopathy, physiotherapy, naprapathy, force, motor skill, biomechanics, dosage, dose-response, education, performance, psychomotor, back, neck, spine, thoracic, lumbar, pelvic, cervical and sacral. Data were extracted and reported descriptively for the following domains: general study characteristics, number of and characteristics of individuals who delivered/received SM, region treated, equipment used and force-time characteristics of SM.

Results

Of 7,607 records identified, 66 (0.9%) fulfilled the eligibility criteria and were included in the analysis. Of these, SM was delivered to the cervical spine in 12 (18.2%), the thoracic spine in 40 (60.6%) and the lumbopelvic spine in 19 (28.8%) studies. In 6 (9.1%) studies, the spinal region was not specified. For SM applied to all spinal regions, force-time characteristics were: preload force (range: 0-671N); peak force (17-1213N); rate of force application (202-8700N/s); time to peak thrust force (12-938ms); and thrust duration (36-2876ms).

Conclusions

Considerable variability in the reported kinetic force-time characteristics of SM exists. Some of this variability is likely due to differences in SM delivery (e.g. different clinicians) and the measurement equipment used to quantify force-time characteristics. However, improved reporting in certain key areas could facilitate more sophisticated syntheses of force-time characteristics data in the future. Such syntheses could provide the foundation upon which dose-response estimates regarding the clinical effectiveness of SM are made.

Supplementary Information

The online version contains supplementary material available at 10.1186/s12998-023-00512-1.

Keywords: Spinal manipulation, Biomechanics, Force-time characteristics, Kinetics, Kinematics, Spine Pain

Introduction

The prevalence of musculoskeletal disorders, including low back and neck pain, is increasing globally [1, 2]. Based on age-standardized disability-adjusted life years, musculoskeletal disorders are currently ranked the 5th highest globally compared to a ranking of 10th in 1990 [3, 4]. In 2017, low back pain was the most prevalent musculoskeletal disorder globally (36.8%), with neck pain the third most prevalent (18.4%). These disorders are not only disabling but also costly, with low back and neck pain having the highest amount of health care spending by payor in the United States (US$134.5 billion in 2016) [5]. Conservative treatments (e.g. spinal manipulation (SM)) are recommended and effective treatments for musculoskeletal disorders as part of multimodal therapy [69]. SM is characterized by a single high-velocity, low-amplitude (HVLA) thrust delivered to a joint with the intention of moving the articulation past its physiological range of motion but without exceeding its anatomic limit [10]. Force-time characteristics such as preload and peak force, rate of force application and thrust duration can be measured during the application of SM, allowing for biomechanical quantification of the intervention. Understanding these force-time characteristics is the first step towards identifying possible active ingredient/s responsible for the clinical effectiveness (e.g. decreased pain and increased range of motion (ROM) of the intervention). However, only a few studies quantify the delivery of SM and those that do, do so heterogeneously. Therefore, interpretation of reported results in this area is difficult. Highlighting this, to our best knowledge, there has been only one attempt to synthesise the literature reporting on the force-time characteristics of SM delivered to all regions of the spine [11]. In this 2010 systematic review, preload and peak forces delivered during SM were collated from 15 studies (cervical: n = 4; thoracic: n = 8; and lumbopelvic: n = 3). Downie and colleagues concluded that heterogeneity in the included studies precluded a standardized biomechanical description of HVLA SM but that a relationship between preload, peak force and thrust duration was present. The authors recommended improved reporting of SM force-time characteristics when assessing the clinical efficacy of HVLA SM (e.g. in clinical trials). More recently, Gyer and colleagues performed a critical literature review of 20 studies (humans: n = 12) in which SM was delivered to the thoracic (n = 5), lumbar (n = 6) or, both regions (n = 1) [12]. While force-time characteristics of SM (e.g. thrust force and duration) were reported, the authors primarily investigated the relationship between force-time characteristics of SM and physiological and clinical outcomes. In summary, it was reported that there exists a dose-response relationship between force-time characteristics of SM and transient physiological outcomes (e.g. electromyographical responses); however, it remains unknown what effect varying force-time characteristics of SM might have on clinical outcomes.

As such, improved reporting would provide a starting point for quantification of minimum thresholds (or dosages), for a range of force-time characteristics (e.g. thrust force and duration) and ultimately, for the determination of how these parameters affect the clinical effectiveness of SM. To date, such thresholds have been hypothesised but not systematically investigated [13, 14]. Indeed, similar findings were reported in an earlier scoping review on SM frequency and dosage effects on clinical and physiological outcomes which concluded that dosage effects clearly influence short-term physiological responses to manipulation but found no relationship between the force-time characteristics of SM delivery and clinical outcomes such as decreased pain and/or increased range of motion [15]. It is possible that heterogeneity in the literature (as reported by Downie and colleagues [11]) could be responsible for the observed lack of relationship between SM force-time characteristics and clinical outcomes. Additionally, the existence of a threshold above which the nervous system is sufficiently stimulated to realise a favourable clinical outcome could partially explain why clinical improvements have been reported in studies using different therapeutic approaches [1618]. Therefore, the aim of this study was to synthesise the existing literature describing biomechanical (kinetic) parameters in the delivery of manual SM.

Methodology

This scoping literature review was conducted in 5 stages as outlined by Arksey and O’Malley [19]. Specifically: (i) the research question was identified; (ii) potentially relevant studies were identified; (iii) relevant studies were selected; (iv) data were charted; and (v) results were generated by collating, summarizing and reporting the data. The final step (optional consultation process) was not included as it was deemed to be unnecessary in the context of the current study. The Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) statement was used to report the data [20]. The protocol was designed by an international, interprofessional team of chiropractors and physiotherapists with relevant methodological and clinical expertise and registered at the Open Science Framework Registry (https://osf.io/3mqjs/). Protocol deviations included that this study was originally designed (and the searches conducted) to capture information concerning the force-time characteristics of both SM and spinal mobilization (SMob). However, due to the large quantity of data published on this topic, it was decided to report the force-time characteristics of SM and SMob separately. Secondly, it was decided to exclude studies reporting on SM delivered to animals as it was unknown how comparable (biomechanically) the delivery of the intervention was to SM delivered to humans.

Eligibility criteria

Eligibility criteria were selected by the research team using the Sample, Phenomenon of Interest, Design, Evaluation, Research Type (SPIDER) search concept tool [21].

Inclusion criteria

S – the sample population was humans (of any age) and inanimate objects (e.g. instrumented tool, manikin);

PI – the phenomenon of interest was manually delivered SM, delivered by any regulated health professional (e.g. chiropractor or physiotherapist) or student enrolled at an accredited institution;

D – observational study designs (e.g. case series studies, cohort and case-control studies);

E – kinetic variables of the intervention (e.g. force-time characteristics); and

R – original quantitative research data from studies utilizing SM as either the sole intervention or as a comparator.

Exclusion criteria

The following exclusion criteria were used: (i) SM and/or SMob delivered by a mechanical instrument or device; (ii) all other therapeutic modalities; (iii) manuscript not published in English, French or German; and (iv) studies that had been retracted, were secondary analyses, trial registrations, protocols, clinical practice guidelines, commentaries, editorials, conference proceedings or single case studies.

Search strategy

The following databases were searched from inception to 4 October 2022: MEDLINE(Ovid), Embase, CINAHL, ICL, PEDro and Cochrane Library. Reference lists of included studies were screened to insure all relevant literature was captured. The search strategy was informed by subject specific and methodological experts. The following search terms and derivatives were adapted for each search engine: (spine, spinal, manipulation, mobilization or mobilisation, musculoskeletal, chiropractic, osteopathy, physiotherapy, naprapathy, force, motor skill, biomechanics, dosage, dose-response, education, performance, psychomotor, back, neck, spine, thoracic, lumbar, pelvic, cervical and sacral). Search strategies for all databases are provided in Appendix 1.

Study selection process

Records retrieved from the electronic searches were exported to the Rayyan© online platform (2022) [22] and duplicate records were removed. Groups of two authors (LG and LN; LG and IP; LG and MP) independently screened potentially eligible studies in a step-wise process, beginning with review of each title and abstract. Full-texts of the studies remaining after the first phase of screening were retrieved and further screened against the eligibility criteria by groups of two authors (LG and LN; LG and IP). Any disagreements regarding inclusion were resolved by consensus and if consensus could not be reached, disagreements were resolved by a third author (MD).

Data extraction

Data were extracted from eligible studies by groups of two authors (LG and LN; LG and MP). These data included: (i) general study characteristics (e.g. title, author, year and country of publication and type of study); (ii) general study information (e.g. individual who delivered the intervention [e.g. clinician, student], professional qualification of individual delivering the intervention [e.g. chiropractor, physiotherapist], years of clinician experience/number of student hours, number of clinicians/students who delivered SM or SMob, recipient [e.g. human, manikin], number of recipients, whether the intervention was SM or SMob [and grade of mobilization], the region treated [e.g. cervical, thoracic] and the measurement equipment used to record force-time characteristics of the intervention); and (iii) force-time characteristics of SM (e.g. preload and peak forces, rate of force application). Data reporting on SMob will be published elsewhere (manuscript in preparation). Given the focus on describing and detailing studies that fulfilled eligibility criteria to enable the study aim to be fulfilled, no assessment of study quality was performed.

Data synthesis

Data are reported using descriptive statistics (mean, standard deviation and range) where possible. Deviations to this are indicated in the tables (e.g. 95% confidence intervals or median and interquartile range) and reflect how the data were reported in the original studies. Frequencies and proportions of trials reporting on each of the specified domains above were calculated in Microsoft Excel (Office 365, Microsoft Corporation, USA).

To streamline the large amount of data reported here, the following decisions were made regarding how to best report the data and are indicated in the tables: (i) for studies reporting forces measured in 3-dimensions (3D) and including the resultant forces (i.e. the total forces applied), only the resultant forces are reported; and (ii) for studies measuring forces applied in 3D but not including the resultant forces, only the forces measured in the primary direction of applied force are reported in the tables (e.g. for prone posterior-anterior thoracic SM, the vertical forces are reported). Regarding the reporting of metrological data of the equipment used to measure the force-time characteristics, a consensus was reached by two authors (LG and MD) as to whether adequate information was provided. In cases where metrological details were reported (e.g. it was stated that calibration of equipment was performed and/or values for equipment accuracy were provided) but no further information was given and/or it was not possible to know how these values were obtained, this was recorded as metrological data were not provided. Considering definitions used in the literature to describe the duration of applied SM, considerable variability was observed. For example, the reporting of time to peak thrust force (i.e. from the end of preload to the peak force of the thrust) was often described as thrust duration [23], yet in other instances, both time to peak thrust force and thrust duration (i.e. the duration of force application (e.g. [24]) were reported. To ensure the correct reporting of this data, the following steps were taken to determine which domain was reported: (i) when the definition was provided in the manuscript, this was used; (ii) if the definition was not provided but figure/s and/or graph/s were provided, these were used; and (iii) if the definition and figure/s and/or graphs were not provided, the terminology used by the original authors was kept. This decision was achieved by consensus of the two independent data extractors (LG and LN; LG and MP).

Results

There were 7,607 records initially identified by the electronic searches (Fig. 1). A total of 3,981 unique records remained after de-duplication (n = 3,626). After title and abstract screening, full texts of the 247 remaining reports were screened. Of these, 66 reported on SM, fulfilled the eligibility criteria and were included in the analysis. The reference list for these studies is provided in Appendix 2 and the reference number provided in each of the tables relates to the numbering in this Appendix. The most common reasons for exclusion were: the paper reported on the wrong outcome (e.g. did not report on the force time parameters of SM (n = 56)) and original data were not reported (e.g. the paper was a review (n = 32)).

Fig. 1.

Fig. 1

PRISMA flow diagram

Of the 66 included studies, 30 (45.5%) were published in the previous 10 years (Table 1). Most studies were conducted in Canada (n = 28, 42.4%), followed by the USA (n = 23, 34.8%). Typically, the study design was cross-sectional (n = 54, 81.8%), with SM delivered by clinicians only (i.e. no students were involved) (n = 43, 65.2%), whose profession was chiropractic (n = 57, 86.4%). In the 54 (81.8%) studies in which SM was delivered by clinicians, clinicians with more than 5 years of experience were most commonly involved (n = 26, 47.3%). However, clinician experience was not reported in 18 (32.7%) studies. When SM was delivered by a student (n = 23, 34.8%), the number of HVLA manual SM training hours was not reported in 20 (87.0%) studies. In most studies, the number of individuals (i.e. clinicians and/or students) delivering SM was between 1–49 (n = 50, 75.8%), with only 1–2 individuals delivering SM in 27 (54.0%) studies. SM was delivered to adults (18–65 years) in 27 (40.9%) studies, with the characteristics of the participants to which SM was delivered not reported in 11 (16.7%) studies. The number of individuals receiving SM was reported as between 1–49 in 59 (89.4%) studies, with only 1–2 individuals receiving SM in 28 (47.5%) studies. SM was most commonly delivered to the thoracic spine (n = 40, 60.6%) and the lumbopelvic spine (n = 19, 28.8%). The SM ‘technique’ (e.g. ‘toggle’, ‘Diversified’, ‘Gonstead’) was reported in 63 (95.5%) studies. Force-time characteristics were measured at the clinician-patient interface in 23 (34.8%) studies, the patient-table interface in 21 (31.8%) studies, both interfaces in 6 (9.1%) studies and was not reported in 16 (24.2%) studies. Metrological data of the measurement equipment were not reported in 53 (80.3%) studies. Regarding force-time characteristics, the following were reported: preload force in 42 (63.6%) studies; peak force in 57 (86.4%) studies; rate of force application in 34 (51.5%) studies; time from end of preload force to peak force of thrust in 36 (54.5%) studies; and thrust duration in 21 (31.8%) studies.

Table 1.

Overall summary of studies reporting on the force-time characteristics of spinal manipulation (SM) (n = 66)

n (%) n (%)
Year, n = 66 Who received SM, n = 66
2013 to 2022 30 (45.5) Adult (18 to 65y) 27 (40.9)
2003 to 2012 18 (27.3) Geriatric (> 65y) 1 (1.5)
1993 to 2002 18 (27.3) Cadaver 2 (3.0)
Country, n = 66 Instrumented tool/force plate 7 (11.0)
Australia 2 (3.0) Mannikin 16 (24.2)
Belgium 2 (3.0) Mixed 2 (3.0)
Canada 28 (42.4) Unclear 11 (16.7)
China 1 (1.5) Number of individuals receiving SM, n = 66
England 3 (4.5) 1 or 2 28 (42.4)
France 4 (6.1) 1 to 49 59 (89.4)
Italy 2 (3.0) 50 to 99 5 (7.6)
Korea 1 (1.5) 100 to 149 1 (1.5)
Spain 1 (1.5) Not reported 1 (1.5)
Unclear 1 (1.5) Region SM delivered to, n = 66*
USA 23 (34.8) Cervical 12 (18.2)
Study type, n = 66 Thoracic 40 (60.6)
Cross-sectional 54 (81.8) Lumbopelvic 19 (28.8)
Prospective 9 (13.6) Not specified 6 (9.1)
Both 1 (1.5) Technique reported, n = 66
Unclear 2 (3.0) Yes 63 (95.5)
Individual who delivered SM, n = 66 No 3 (4.5)
Practitioner 43 (65.2) Measurement interface, n = 66
Student 11 (16.7) Clinician-patient 23 (34.8)
Both 11 (16.7) Patient-table 21 (31.8)
Unclear 1 (1.5) Both 6 (9.1)
Profession, n = 66 Other/not reported 16 (24.2)
Chiropractor 57 (86.4) Metrological data reported, n = 66
Medical Doctor 1 (1.5) Reported 13 (19.7)
Physiotherapist 4 (6.1) Not reported 53 (80.3)
Other/not reported 4 (6.1) Preload force, n = 66
Experience (clinician) n = 55 Reported 42 (63.6)
> 5yr 26 (47.3) Not reported 24 (36.4)
Mixed 11 (20.0) Peak force, n = 66
Unclear 18 (32.7) Reported 57 (86.4)
Hours of training (student) n = 23 Not reported 9 (13.6)
Reported 3 (13.0) Rate of force application, n = 66
Not reported 20 (87.0) Reported 34 (51.5)
Number of individuals delivering SM, n = 66 Not reported 32 (48.5)
1 or 2 27 (40.9) Time to peak, n = 66
1 to 49 50 (75.8) Reported 36 (54.5)
50 to 99 7 (10.6) Not reported 30 (45.5)
100 to 149 7 (10.6) Thrust duration, n = 66
Not reported 2 (3.0) Reported 21 (31.8)
Not reported 45 (68.2)

Abbreviations: n: number of studies, SM: spinal manipulation, USA: United States of America, y: years, >: greater than, *: sums to > 100% as some studies reported on SM delivered to multiple spinal regions

Cervical spine

Of the 66 included studies, 12 (18.2%) reported on SM delivered to the cervical spine (Table 2). Of these 12 studies, SM was delivered to humans in 9 (75.0%) studies and to inanimate objects (i.e. human analogue manikins: 2 (66.7%); load cell: 1 (33.3%)) in 3 (25.0%) studies. Ranges of reported force-time characteristics are reported in Table 3 (summary) and Appendix 3, Table A (full).

Table 2.

Summary of studies reporting on the force-time characteristics of spinal manipulation (SM) delivered to the cervical spine of humans (n = 9) and inanimate objects (e.g. human analogue manikins, instrumented tools) (n = 3)

Author/s
Year, Country
SM delivery
Profession (n)
Experience Recipient/s (n) Location/s Technique/s Interface/s Measurement equipment Metrological data
Humans

Kawchuk et al.

1992, Canada40

Clin

Chiro (2)

> 5y NR (2) C1/C2 Toggle Clin-pat Force pad No

Herzog et al.

1993, Canada35

Clin

Chiro (60)

NR NR (58) Cervical Lateral-medial Clin-pat Force pad No

Kawchuk et al.

1993, Canada41

Clin

Chiro (5)

NR NR (NR) NR Lateral break/ Gonstead/Toggle/Rotation Clin-pat Force pad No

Van Zoest et al.

2003, England65

Clin

Chiro (2)

> 5y Adult (10) Mid cervical Diversified Clin-pat Force sensor Yes

Symons et al.

2012, Canada57

Clin

Chiro (2)

> 5y

Mixed (33)

Living: 28

Cadavers: 5

Living: MP

Cadavers: C2-3/ C4-5

Diversified Clin-pat Pressure pad No

Anderst et al.

2018, USA4

Clin

Chiro (1)

> 5y Adult (5) C3/C4/C5 Pillar push Clin-pat Pressure pad No

Gorrell et al.

2020, Canada29

Clin

Chiro (1)

> 5y Adult (27) C1/C2/C6/ C7 Diversified Clin-pat Pressure pad No

Duquette et al.

2021, Canada23

Stud

Chiro (76)

NR (4th y) Mixed ages (76) NR Lateral index/ pillar push Pat-table Force plate No

Chang et al.

2022, China10

Clin

MD (1)

> 5y Adult (34) C5 Seated resisted rotation Clin-pat Mechanical measurement system No
Inanimate objects

Graham et al.

2010, Australia30

Clin & Stud

Chiro (13)

Clin: >5y

Stud: NR (5th y)

Load cell (1) NR Toggle-recoil Clin-tool Load cell No

Triano et al.

2017, Canada64

Clin

Chiro (1)

> 5y Manikin (1) Cervical

Supine

rotational

Clin-man

& Man-table

Load cell & Force plate Yes

Duquette et al.

2021, Canada23

Stud

Chiro (76)

NR (4th y) Manikin (1) NR Lateral index/ pillar push Man-table Force plate No

All superscript numbers in the first column refer to Appendix 2. Abbreviations: C: cervical, Chiro: chiropractor, Clin: clinician, Man: manikin, MD: medical doctor, Mixed: experience of clinicians both > and < 5 years, MP: most painful level, (n): number of participants, NR: not reported, Pat: patient, SM: spinal manipulation, Stud: students, y: years, >: greater than

Table 3.

Summary of force-time characteristics reported by region for studies reporting on spinal manipulation (SM) (n = 66)

Location of measurement
n (%)
Metrologic data reported
n (%)
Preload force reported
range (N)
Peak force
reported
range (N)
Rate of force application reported range (N/s) Time to peak reported
range (ms)
Thrust duration reported
range (ms)
Cervical spine (n = 12)

Humans

(n = 9)

Clinician-patient: 8 (88.9) 1 (11.1) 0-162 41–407 440–1787 30–195 90–130
Patient-table: 1 (11.1) 0 10–13 47–49 NR NR NR
Inanimate objects (n = 3) Clinician-tool: 1 (33.3) 0 0–5 18–246 NR 20–100 NR
Man-table: 1 (33.3) 0 19–23 123–126 NR NR NR
Both: 1 (33.3) 1 (33.3) NR 20–112 NR NR NR
Thoracic spine (n = 40)

Humans

(n = 27)

Clinician-patient: 11 (40.7) 1 (3.7) 0-254 212–573 416–7000 108–541 318–1330
Patient-table: 9 (33.3) 5 (18.5) 41–671 290–878 1769–8700 91–280 120–310

Both: 4 (14.8)

Clinician-patient

Patient-table

3 (11.1)

260–273

217–310

470–1213

463–1044

1645–3109

1639–15,592*

165–181

96–170

NR

NR

Clinician-ground: 2 (7.4) 0 338–399 564–658 NR NR NR
Accelerometers: 1 (3.7) 0 NR NR NR NR 61
Inanimate objects (n = 13) Man-table: 5 (38.5) 3 (23.1) 137–172 337–536 2381–3490 109–137 87–198
Within man: 1 (7.7) 0 105–133 287–304 1473–2495 82–132 NR
Within man & clinician-ground: 4 (30.8) 0 31–177 404–660 2557–4487 101–266 NR
Clinician-man & man-table: 1 (7.7) 1 (7.7) NR 17–393 NR NR NR
NR: 2 (15.4) 0 13–254 212–563 416–3780 109–541 318–1330
Lumbopelvic spine (n = 19)

Humans

(n = 12)

Clinician-patient: 5 (41.7) 1 (8.3) 20–190 106–550 202–1621 164–938 200–2876
Patient-table: 4 (33.3) 0 NR 128–516 630–3813 NR 320–440
Both: 1 (8.3) 0 NR 242–940 NR 243 NR
Clinician-patient & clinician-ground: 1 (8.3) 0 106 328 1078 261 770
Accelerometers: 1 (8.3) 0 NR NR NR NR 139
Inanimate objects (n = 7) Clinician-man/tool: 3 (42.9) 0 94.4 433 2692 154 41–574
Man-table: 2 (28.6) 0 95–163 324–714 2450–4640 142–176 NR
Both: 1 (14.3) 1 (14.3) NR 18–387 NR NR NR
Clinician-man & clinician-man 1 (14.3) 0 NR NR NR NR 371–441
No region reported (n = 6)
Inanimate objects (n = 6) Clinician-tool: 6 (100.0) 0 9–77 46–387 551–1692§ 12–251 36–98

Note: in instances where only one value is reported, data were only reported by one study. Abbreviations: Both: clinician-patient/equipment & patient/equipment-table, equip: equipment, man: manikin, ms: milliseconds, n: number of studies, N: Newtons, NR: not reported, s: seconds, tool: something to which SM was delivered (e.g. load cell), *: 15,592 N/s reported, likely a mistake [29], §: this is reported as N/ms, likely a mistake [30]

Thoracic spine

Of the 66 included studies, 40 (60.6%) reported on SM delivered to the thoracic spine (Tables 4 and 5). Of these 40 studies, SM was delivered to humans in 27 (67.5%) studies and to inanimate objects (i.e. human analogue manikins: 12 (92.3%); strain gauge: 1 (7.7%)) in 13 (32.5%) studies. Ranges of reported force-time characteristics are reported in Table 3 (summary) and Appendix 3, Tables B-C (full).

Table 4.

Summary of studies reporting on the force-time characteristics of spinal manipulation (SM) delivered to the thoracic spine of humans (n = 27)

Author/s
Year, Country
SM delivery
Profession (n)
Experience Recipient/s (n) Location/s Technique/s Interface/s Measurement equipment Metrological data
Humans

Brennan et al.

1991, USA6

Clin

Chiro (NR)

NR Adult (80) T1-6 PA Pat-table Force plate No

Brennan et al.

1992, USA7

Clin

Chiro (NR)

NR Adult (6) T2-6 HVLA Pat-table Force plate No

Conway et al.

1993, Canada14

Clin

Chiro (1)

NR NR (10) T4 UL hypothenar Clin-pat Pressure pad No

Herzog et al.

1993, Canada35

Clin

Chiro (60)

NR NR (58) T4 PA hypothenar Clin-pat Force pad No

Gal et al.

1994, Canada27

Clin

Chiro (1)

NR Cadaver (2) T11 Hypothenar Clin-pat Pressure pad No

Cohen et al.

1995, USA11

Clin & Stud

Chiro (30)

Clin: Mixed

Stud: NR

NR (15) T3-T10 BL transverse thenar Pat-table Force platform No

Herzog et al.

1995, Canada36

Clin

Chiro (1)

NR Adult (2) T3/T7/T9 PA hypothenar Clin-pat Force pad No

Gal et al.

1997, Canada28

Clin

Chiro (1)

NR Cadaver (2) T10-12 PA hypothenar Clin-pat Pressure pad No

Kirstukas & Backman

1999, USA43

Clin

Chiro (2)

> 5y Adult (7) T6-T9 UL thoracic

Clin-pat &

Pat-table

Pressure sensor &

Load cells

Yes

Herzog et al.

2001, Canada37

Clin

Chiro (1)

< 5y Adult (20) T3-10 PA hypothenar Clin-pat Force pad No

Van Zoest et al.

2003, England65

Clin

Chiro (2)

> 5y Adult (10) T1-2/T4-5/ T8-9 Diversified Clin-pat Piezoelectric force sensor Yes

Forand et al.

2004, Canada25

Clin

Chiro (28)

Mixed NR (9) T4/T9 PA (clin choice) Clin-pat Sensor pad No

Campbell & Snodgrass

2010, Australia9

Clin

Physio (1)

> 5y Adult (24) T3-T10 Anterior AP Pat-table Load cells Yes

Triano et al.

2011, Canada62

Clin & Stud

Chiro (50)

Clin: >5y

Y1: 102 h

Y2: 218 h

Y3: 326 h

Y4: 409 h

NR (50) Upper Hypothenar transverse push Pat-table Force plate Yes

Cambridge et al.

2012, Canada8

Clin

Chiro (3)

> 5y Adult (19) T4-12 NR Pat-table Force plate Yes

Gudavalli

2014, USA32

Clin

Chiro (3)

NR NR (5) Thoracic PA Clin-pat Force transducer No

Williams & Cuesta-Vargas

2014, Spain66

Clin

NR (2)

> 5y Adult (13) T5/6 PA Clin-pat Inertial sensor No

Dunning et al.

2017, Italy22

Clin

Physio (1)

> 5y Adult (32) T1/2 Lateral break Skin mounted accelerometers Accelerometer No

Engell et al.

2019, Canada24

Clin

Chiro (1)

> 5y Adult (9) T7 BL hypothenar push/Carver bridge

Clin-pat &

Pat-table

Load cells &

Force plate

No

Beyer et al.

2020, Belgium5

Clin & Stud

NR (4)

Clin: NR

Stud: NR (5th y)

Adult (16) NR AP Pat-ground Force plate No

Dugailly et al.

2020, Belgium21

Clin & Stud

NR (30)

Clin: NR

Stud: NR

Adult (12) NR AP Pat-ground Force platform No

Gorrell et al.

2020, Canada29

Clin

Chiro (1)

> 5y Adult (27) T1/T4 PA Clin-pat Pressure pad No

Joo et al.

2020, Korea39

Clin

Physio (1)

NR Adult (32) T3/T7/T12 AP clenched fist/PA BL knife Pat-table Force plate No

Pasquier et al.

2020, France51

Stud

Chiro (136)

NR (3rd -6th y) Adult (136) NR BL thenar push/modified pisiform Pat-table Force plate Yes

Funabashi et al.

2021, Canada26

Clin

Chiro (1)

> 5y Geriatric (18) T1-12 Clin choice

Clin-pat &

Pat-table

Load cells &

Force plate

Yes

Duarte et al.

2022, Canada20

Clin

Chiro (1)

NR Adult (19) T6-9 PA Pat-table Force plate Yes

Thomas et al.

2022, Canada58

Clin

Chiro (1)

> 5y Adult (40) T7 Cross BL

Clin-pat &

Pat-table

Load cells &

Force plate

Yes

All superscript numbers in the first column refer to Appendix 2. Abbreviations: AP: anterior-posterior, BL: bilateral, Chiro: chiropractor, Clin: clinician, h: hours, HVLA: high velocity low amplitude, Mixed: experience of clinicians both > and < 5 years, (n): number of participants, NR: not reported, PA: posterior-anterior, Pat: patient, Physio: physiotherapist, SM: spinal manipulation, Stud: students, T: thoracic, UL: unilateral, Upper: upper thoracic spine, y: years, >: greater than, <: less than

Table 5.

Summary of studies reporting on the force-time characteristics of spinal manipulation (SM) delivered to the thoracic spine of inanimate objects (e.g. human analogue manikins, instrumented tools) (n = 13)

Author/s
Year, Country
SM delivery
Profession (n)
Experience Recipient/s (n) Location/s Technique/s Interface/s Measurement equipment Metrological data
Inanimate objects

Descarreaux et al.

2005, Canada16

Clin & Stud

Chiro (43)

Clin:>5y

Stud: NR (2nd /4th /final y)

Manikin (1) NR Hypothenar transverse

In Man &

Clin-ground

Strain gauge &

Force plate

No

Descarreaux et al.

2006, Canada17

Stud

Chiro (31)

NR (4th y) Manikin (1) NR Hypothenar transverse

In Man &

Clin-ground

Load cell &

Force plate

No

Descarreaux & Dugas

2010, Canada18

Stud

Chiro (33)

NR (1st y) Manikin (1) NR Hypothenar transverse

In Man &

Clin-ground

Strain gauge & Force platform No

Harvey et al.

2011, Canada/ USA34

Stud

Chiro (87)

Clin: 330 h

Stud: 330 h

Manikin (1) NR Hypothenar transverse

In Man &

Clin-ground

Strain gauge & Force platform No

Stemper et al.

2011, USA56

Clin

Chiro (2)

> 5y Manikin (1) T7-T8 Clin choice NR Rotational potentiometer No

Gudavalli

2014, USA32

Clin

Chiro (3)

NR Manikin (1) Upper/ mid/ lower PA NR NR No

Triano et al.

2015, Canada63

Clin

Chiro (38)

> 5y Manikin (1) T9 BL hypothenar/ BL thenar/cross-bilateral Man-table Force plate Yes

Starmer et al.

2016, USA55

Stud

Chiro (125)

NR (1st y) Manikin (1) T9 BL hypothenar/ BL thenar/cross-bilateral Man-table Force plate No

Pasquier et al.

2017, France49

Stud

Chiro (103)

NR

(1st /3rd /5th y)

Strain gauge (1) NR PA transverse push In Man Strain gauge No

Triano et al.

2017, Canada64

Clin

Chiro (1)

> 5y Manikin (1) NR BL-thumb/ ‘knife-edge’

Clin-Man &

Man-table

Load cell &

Force plate

Yes

Lardon et al.

2019, France44

Stud

Chiro (113)

NR (1st y) Manikin (1) NR PA Man-table Force plate Yes

Pasquier et al.

2019, France50

Stud

Chiro (137)

NR (4th /5th y) Manikin (1) NR BL thenar push Man-table Force plate Yes

Shannon et al.

2020, USA54

Clin & Stud

Chiro (16)

Clin: Mixed

Stud: NR (7–8/10trimesters)

Manikin (1) T4 PA BL thenar Man-table Force plate No

All superscript numbers in the first column refer to Appendix 2. Abbreviations: BL: bilateral, Chiro: chiropractor, Clin: clinician, h: hours, Lower: lower thoracic spine, Man: manikin, Mid: mid thoracic spine,Mixed: experience of clinicians both > and < 5 years, (n): number of participants, NR: not reported, PA: posterior-anterior, SM: spinal manipulation, Stud: students, Upper: upper thoracic spine, T: thoracic, y: years, >: greater than

Lumbopelvic spine

Of the 66 included studies, 19 (28.8%) reported on SM delivered to the lumbopelvic spine (Table 6). Of these 19 studies, SM was delivered to humans in 12 (63.2%) studies and to inanimate objects (i.e. human analogue manikins: 5 (71.4%); force transducer: 1 (14.3%); both a rigid table-top and a human analogue manikin: 1 (14.3%)) in 7 (36.8%) studies. Ranges of reported force-time characteristics are reported in Table 3 (summary) and Appendix 3, Table D (full).

Table 6.

Summary of studies reporting on the force-time characteristics of spinal manipulation (SM) delivered to the lumbopelvic spine of humans (n = 12) and inanimate objects (e.g. human analogue manikins, instrumented tools) (n = 7)

Author/s
Year, Country
SM delivery
Profession (n)
Experience Recipient/s (n) Location/s Technique/s Interface/s Measurement equipment Metrological data
Humans

Hessell et al.

1990, Canada38

Clin

Chiro (2)

NR NR (6) SIJ

Thompson

technique

Clin-pat Force pad No

Herzog et al.

1993, Canada35

Clin

Chiro (60)

NR NR (58) SIJ PA drop-piece Clin-pat Force pad No

Triano & Schultz

1997, USA59

Clin

Chiro (6)

Mixed Adult (11)

Lumbar/

SIJ

Mamillary push/ hypothenar ischial/

long lever lumbar

Pat-table Force plate No

Rogers & Triano

2003, USA53

Stud

Chiro (16)

NR (2nd sem) NR (16) L5 Mamillary push Pat-table Force plate No

Van Zoest & Gosselin

2003, England65

Clin

Chiro (2)

> 5y Adult (10) SIJ Diversified Clin-pat Force sensor Yes

Triano et al.

2004, USA/Canada60

Clin & Stud

Chiro (85)

Clin: >5y

Stud: ~100 h

Adult (85) L4 Mamillary push Pat-table Force plate No

Triano et al.

2006, USA61

Stud

Chiro (40)

NR (2nd y) Adult (40) L4 Mamillary push Pat-table Force plate No

Gudavalli et al.

2013, USA31

Clin

Chiro (3)

> 5y Adult (5) NR Side posture

Clin-pat &

Clin-ground

Force transducer

& Force plate

No

Gudavalli

2014, USA32

Clin

Chiro (3)

NR NR (5)

Lumbar/

SIJ

Side-lying Clin-pat Force transducer No

Gudavalli & Rowell

2014, USA33

Clin

Chiro (2)

NR Adult (5)

Lumbar/

SIJ

Side-lying Clin-pat Force transducer No

Currie et al.

2016, USA15

Clin

Chiro (2)

> 5y Adult (17) L3/SIJ

Hypothenar

side-lying

Clin-pat &

Pat-table

Force transducer

& Force plate

No

Mourad et al.

2019, Italy46

Clin

Physio (1)

> 5y Adult (34) L5/S1

Mamillary process

body drop

Skin-mounted

accelerometers

NA No
Inanimate objects

Adams et al.

1984, USA1

Clin

Chiro (37)

Mixed Rigid tabletop / Manikin (1) Ilium/L5 Thompson technique/ single hand contact

Clin-table/

Clin-man

Force transducer No

Adams & Wood

1984, USA2

Clin & Stud

Chiro (74)

Clin: Mixed

Stud: NR (8th quart)

Manikin (1) Ilium/L5

Pisiform contact/

Thompson technique

Clin-man Force transducer No

Adams & Wood

1985, NR3

Clin & Stud

Chiro (148)

Clin: Mixed

Stud: NR (8th /10th /

12th quart)

Manikin (1) PSIS/L5 Thomson technique Clin-man Force transducer No

Gudavalli et al.

2013, USA31

Clin

Chiro (2)

> 5y Force transducer (1) NR HVLA Clin-force transducer Force transducer on force plate No

Owens et al.

2016, USA47

Clin

Chiro (11)

Mixed Manikin (1) PSIS/L5 Prone/side-posture Gonstead Man-table Force plate No

Owens et al.

2017, USA48

Clin

Chiro (11)

Mixed Manikin (1) L3 Reinforced pisiform Gonstead Man-table Force plate No

Triano et al.

2017, Canada64

Clin

Chiro (1)

> 5y Manikin (2)

Lumbar/

SIJ

Prone-assisted/

lateral recumbent

Clin-man &

Man-table

Load cell &

Force plate

Yes

All superscript numbers in the first column refer to Appendix 2. Abbreviations: Chiro: chiropractor, Clin: clinician, h: hours, HVLA: high velocity low amplitude, L: lumbar, Man: manikin, Mixed: experience of clinicians both > and < 5 years, (n): number of participants, NR: not reported, PA: posterior-anterior, Pat: patient, Physio: physiotherapist, PSIS: posterior superior iliac spine, quart: quarter, sem: semester, SIJ: sacroiliac, SM: spinal manipulation, Stud: students, y: years, >: greater than

No region specified

Of the 66 included studies, 6 (9.1%) reported on SM delivered to a non-defined region (Table 7). Of these 6 studies, SM was delivered to a tool in 3 (50.0%) studies, a force table/plate in 2 (33.3%) studies and a rigid surface in 1 (16.7%) study. Ranges of reported force-time characteristics are reported in Table 3 (summary) and Appendix 3, Table E (full).

Table 7.

Summary of studies reporting on the force-time characteristics of spinal manipulation (SM) delivered to inanimate objects (e.g. human analogue manikins, instrumented tools) with no region specified (n = 6)

Author/s
Year, Country
SM delivery
Profession (n)
Experience Recipient/s (n) Location/s Technique/s Interface/s Measurement equipment Metrological data
Inanimate objects

McCarthy et al.

2002, England45

Clin

Chiro (28)

Mixed Tool (1) L vertebra/tool Superior-inferior Clin-tool Strain guage No

Perle & Kawchuk

2005, Canada52

Clin

Chiro (16)

> 5y Rigid surface (1) NR Pisiform/hypothenar with or without arch in hand Clin-tool Pressure sensor No

Kawchuk et al.

2006, Canada42

Clin

Chiro (4)

NR

Force table/

plate (1)

Force mat Hypothenar Clin-tool Load cell No

Colloca et al.

2009, USA12

Clin

Chiro (2)

NR Tool (1) NR Toggle-torque-recoil Clin-tool Load cell No

DeVocht et al.

2013, USA19

Clin & Stud

Chiro (139)

Clin: NR

Stud: NR

Tool (1) Speeder board Toggle recoil Clin-tool Force transducer No

Colloca et al.

2020, UK13

Clin & Stud

Chiro (53)

Clin: Mixed

Stud: NR (3rd /5th y)

Force table/

plate (1)

NR Toggle-torque-recoil Clin-tool Load cell No

All superscript numbers in the first column refer to Appendix 2. Abbreviations: Chiro: chiropractor, Clin: clinician, L: lumbar, Mixed: experience of clinicians both > and < 5 years, (n): number of participants, NR: not reported, Stud: students, SM: spinal manipulation, y: years, >: greater than

Discussion

This review synthesised the current evidence describing force-time characteristics measured during the delivery of manual SM and highlights the considerable variability in these reported parameters. This finding is supported by an earlier systematic review by Downie and colleagues, the only review to date reporting on the force-time characteristics of SM delivered to all regions of the spine [11] and a recent critical literature review by Gyer and colleagues who investigated dose-response effects of the force-time characteristics of SM [12]. The current work is not directly comparable to these previous reviews due to methodological differences (i.e. systematic vs. critical vs. scoping review) and reporting differences (i.e. preload and peak force only vs. preload and peak force, rate of force application, time from end of preload to peak thrust force and thrust duration and data reported for different spinal regions). Additionally, the current search captured 35 additional studies reporting on force-time characteristics measured during SM since the publication of the 2010 systematic review and included considerably more studies reporting on the thoracic (n = 6 vs. n = 27) and lumbar (n = 7 vs. n = 12) spines than the 2022 critical review. This highlights that the current review has exhaustively included studies reporting on force-time characteristics of SM and that there has been a large increase in the number of publications reporting on SM force-time characteristic data in the past ~ 13 years.

Despite this increased reporting, the heterogeneity of the existing literature precluded synthesis of the reported data beyond descriptive analysis. Such heterogeneity included the following factors: (i) there were many SM ‘techniques’ used within and between spinal regions; (ii) SM was delivered by individuals with a wide range of clinical experience (e.g. novice student to experienced clinician); (iii) biomechanical data were collected at different locations (e.g. clinician-patient and patient-table interfaces); and (iv) using a variety of equipment (e.g. pressure sensor, load cells, force plates). Conceivably, this heterogeneity is one reason for the large variability in reported force-time characteristics of SM. While these differences in SM delivery likely reflect the rich tapestry of clinical practice in which treatment is tailored to individual patients chosen by the clinician delivering the intervention, such differences prevent between-study comparisons of results and subsequent statistical synthesis. This is one reason that informed the decision to conduct a scoping, rather than a systematic review. A scoping review allowed this heterogeneity to be captured and thus, this study reports exhaustively the range of force-time characteristics quantifying the delivery of SM. As such, this study provides a comprehensive summary of the force-time characteristics of SM delivered to both humans and inanimate objects.

There is a push within the literature for authors to quantify and report both passive (i.e. SM) [25] and active interventions (e.g. exercise) [26] in sufficient detail to allow for their replication in future research studies. The quantification and subsequent detailed reporting of interventions would facilitate: (i) accurate replication of the intervention in subsequent studies; (ii) improved interpretation of reported outcomes; and (iii) informed reader assessment regarding the applicability of both the intervention and reported outcomes to clinical practice [27]. However, it became evident during data extraction that detailed descriptions of several important items were not provided. Such items included vague or no reporting of: (i) the SM delivered; (ii) the individual who delivered the SM, especially their clinical training and experience; (iii) definitions of how each reported force-time characteristic was defined and/or calculated; (iv) information regarding the location of the applied SM; (v) the number of SM delivered; (vi) the number of SM recipients; and (vii) metrological details of the equipment used to quantify the force-time characteristics of SM.

Recommendations for reporting of SM

For specific examples and suggested descriptions for the recommendations made below, readers are referred to the template for intervention description and replication (TIDieR) checklist (cited above) published by Hoffmann and colleagues in 2014 which provides a guide to be used by: (i) authors, to more easily structure the reporting of their interventions; (ii) reviewers and editors, to assess the descriptions; and (iii) readers, to determine the relevance of the reported results [27]. For examples of detailed reporting specific to SM (as discussed below), readers are referred to the previously cited consensus paper discussing guidelines for the reporting of spinal manipulative therapy interventions [25] and to a recent publication discussing the reporting of measurement equipment metrological details in reference to the quantification of force-time characteristics during SM and SMob [28]. To address the reporting deficiencies identified by the current review, the following general recommendations should be incorporated in future studies and their related publications. Firstly, there should be an adequate description of the applied SM technique. Regarding SM delivery, there should be sufficient detail so that an individual with manual therapy knowledge (e.g. manual therapy researchers, clinicians) would understand what was done and be able to replicate the intervention, including the primary direction of applied force (e.g. posterior-anterior), spinal region treated (e.g. thoracic) and level of treated segment (e.g. T3). Additional information regarding the location of the applied intervention (e.g. spinous process) should also be reported. The individual who delivered the SM should be described, including their training (e.g. physiotherapist, chiropractor) and experience delivering SM (e.g. students with X hours of experience delivering SM). Furthermore, the number of individuals delivering and receiving SM should be clearly reported, as should the number of SM that were delivered (i.e. how many thrusts were actually delivered). Secondly, definitions of how each reported force-time characteristic was defined and/or calculated need to be clearly reported. This allows for the comparison of data across multiple studies and will possibly facilitate meta-analysis of biomechanical data associated with dosage effects of SM in future clinical studies. Thirdly, as there is considerable variability in the reported force-time characteristics of SM, it is suggested that authors include raw data (i.e. non-analysed/non-averaged) to support their results where possible and that ranges are reported alongside other descriptive statistics (e.g. mean and standard deviation) for all reported force-time characteristics, allowing for a more illustrative description of the delivered SM. Finally, detailed description of the location of measurement (e.g. clinician-participant or participant-table) and measurement equipment used to quantify the force-time characteristics, including metrological details such as measurement error, reliability/repeatability, variability and calibration should be provided. With the use of appendices/supplementary files, it is feasible that these data are adequately reported while fulfilling editorial requirements (e.g. word limits).

Limitations

Limitations of the current study include that only manuscripts published in English, French or German were included in the search strategy. Furthermore, as this was a scoping (and not systematic) review, it is possible that some manuscripts reporting on the force-time characteristics of SM were inadvertently not captured by the search strategy. However, every attempt was made to avoid this situation, with a broad search strategy inclusive of many professions that routinely use SM to treat patients with musculoskeletal disorders conducted across several databases, piloting and refinement of the search strategy prior to implementation, and the conduct of the scoping review in a systematic fashion (i.e. using two independent reviewers and data extractors). As such, it is unlikely that any seminal study was missed. Additionally, this review reports only on the kinetic force-time characteristics of SM and does not report on the kinematics of either the individual delivering the thrust and/or those of the recipient. Future reviews could address this gap in the literature by reporting on the kinematic parameters of individuals delivering SM (e.g. change in clinician centre of mass). Additionally, due to a lack of clarity regarding reported definitions of time to peak thrust force and thrust duration, it is possible that our best attempts to correctly classify this data were not sufficient. However, as two authors independently extracted the data prior to discussing and with a third author available for consensus resolution, it is unlikely that this lack of clarity in the original studies is a significant source of error within this study. Furthermore, it is not possible to determine the robustness/reliability of data collected using measurement equipment for which metrological data were not reported. Considering that this limitation applies to over three-quarters of the data reported here, the results should be interpreted with caution.

Conclusion

Considerable variability in the reported kinetic force-time characteristics of SM exists. Some of this variability is likely due to differences in SM delivery and the measurement equipment used to quantify force-time characteristics. However, improved reporting in certain key areas could facilitate more sophisticated synthesises of force-time characteristics data in the future. Such syntheses could provide the foundation upon which dose-response estimates regarding the clinical effectiveness of SM are made.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary Material 1 (22.4KB, docx)
Supplementary Material 2 (22.8KB, docx)
Supplementary Material 3 (67.8KB, docx)

Acknowledgements

The authors would like to acknowledge Dr. Martina Gosteli (The University of Zurich) for her assistance with the literature search.

List of abbreviations

3D

Three dimensional

CINAHL

Cumulative Index to Nursing and Allied Health Literature database

HVLA

High velocity, low amplitude

ICL

Index to Chiropractic Literature database

MEDLINE

Medical Literature Analysis and Retrieval System Online database

ms

Millisecond

N/s

Newtons per second

N

Newtons

n

Number of studies

PEDro

Physiotherapy Evidence database

PRISMA-ScR

Preferred Reporting Items for Scoping Reviews statement

s

Second

SM

Spinal manipulation

SMob

Spinal mobilization

SPIDER

Sample, Phenomenon of Interest, Design, Evaluation, Research Type search concept tool

US

United States

USA

United States of America

Authors’ contributions

LG: conceptualization, methodology, screening, data extraction and curation, formal analysis, project administration, visualization, writing – original draft, review & editing. LN: screening, data extraction, writing – review & editing. MP: screening, data extraction, writing – review & editing. IP: screening, writing – review & editing. PS: methodology, writing – review & editing. NH: methodology, writing – review & editing. MD: conceptualization, methodology, formal analysis, writing – review & editing.

Funding

This project did not receive any funding.

Data Availability

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Footnotes

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Vos T, Lim SS, Abbafati C, Abbas KM, Abbasi M, Abbasifard M, et al. Global burden of 369 diseases and injuries in 204 countries and territories, 1990–2019: a systematic analysis for the global burden of Disease Study 2019. The Lancet. 2020;396(10258):1204–22. doi: 10.1016/S0140-6736(20)30925-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.The Lancet Rheumatology The global epidemic of low back pain. Lancet Rheumatol. 2023;5(6):e305. doi: 10.1016/S2665-9913(23)00133-9. [DOI] [PubMed] [Google Scholar]
  • 3.Safiri S, Kolahi AA, Cross M, Hill C, Smith E, Carson-Chahhoud K, et al. Prevalence, deaths, and disability-adjusted Life Years due to Musculoskeletal Disorders for 195 Countries and Territories 1990–2017. Arthritis Rheumatol. 2021;73(4):702–14. doi: 10.1002/art.41571. [DOI] [PubMed] [Google Scholar]
  • 4.Ferreira ML, de Luca K, Haile LM, Steinmetz JD, Culbreth GT, Cross M, et al. Global, regional, and national burden of low back pain, 1990–2020, its attributable risk factors, and projections to 2050: a systematic analysis of the global burden of Disease Study 2021. Lancet Rheumatol. 2023;5(6):e316–29. doi: 10.1016/S2665-9913(23)00098-X. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Dieleman JL, Cao J, Chapin A, Chen C, Li Z, Liu A, et al. US Health Care spending by Payer and Health Condition, 1996–2016. JAMA. 2020;323(9):863–84. doi: 10.1001/jama.2020.0734. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Blanpied PR, Gross AR, Elliott JM, Devaney LL, Clewley D, Walton DM, et al. Neck Pain: Revision 2017. J Orthop Sports Phys Ther. 2017;47(7):A1–83. doi: 10.2519/jospt.2017.0302. [DOI] [PubMed] [Google Scholar]
  • 7.Bussieres AE, Stewart G, Al-Zoubi F, Decina P, Descarreaux M, Haskett D et al. Spinal manipulative therapy and other conservative treatments for low back Pain: a Guideline from the canadian Chiropractic Guideline Initiative. J Manip Physiol Ther. 2018. [DOI] [PubMed]
  • 8.Bussieres AE, Stewart G, Al-Zoubi F, Decina P, Descarreaux M, Hayden J, et al. The treatment of neck pain-associated disorders and whiplash-associated disorders: a clinical practice guideline. J Manipulative Physiol Ther. 2016;39(8):523–64. doi: 10.1016/j.jmpt.2016.08.007. [DOI] [PubMed] [Google Scholar]
  • 9.Delitto A, George SZ, Van Dillen L, Whitman JM, Sowa G, Shekelle P, et al. Low back Pain. J Orthop Sports Phys Ther. 2012;42(4):A1–57. doi: 10.2519/jospt.2012.42.4.A1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Herzog W. The biomechanics of spinal manipulation. J Bodyw Mov Ther. 2010;14(3):280–6. doi: 10.1016/j.jbmt.2010.03.004. [DOI] [PubMed] [Google Scholar]
  • 11.Downie AS, Vemulpad S, Bull PW. Quantifying the high-velocity, low-amplitude spinal manipulative thrust: a systematic review. J Manipulative Physiol Ther. 2010;33(7):542–53. doi: 10.1016/j.jmpt.2010.08.001. [DOI] [PubMed] [Google Scholar]
  • 12.Gyer G, Michael J, Inklebarger J, Ibne Alam I. Effects of biomechanical parameters of spinal manipulation: a critical literature review. J Integr Med. 2022;20(1):4–12. doi: 10.1016/j.joim.2021.10.002. [DOI] [PubMed] [Google Scholar]
  • 13.Snodgrass SJ, Rivett DA, Sterling M, Vicenzino B. Dose optimization for spinal treatment effectiveness: a randomized controlled trial investigating the effects of high and low mobilization forces in patients with neck pain. J Orthop Sports Phys Ther. 2014;44(3):141–52. doi: 10.2519/jospt.2014.4778. [DOI] [PubMed] [Google Scholar]
  • 14.Gorrell LM, Beath K, Engel RM. Manual and instrument applied cervical manipulation for mechanical neck pain: a randomized controlled trial. J Manipulative Physiol Ther. 2016;39(5):319–29. doi: 10.1016/j.jmpt.2016.03.003. [DOI] [PubMed] [Google Scholar]
  • 15.Pasquier M, Daneau C, Marchand AA, Lardon A, Descarreaux M. Spinal manipulation frequency and dosage effects on clinical and physiological outcomes: a scoping review. Chiropr Man Ther. 2019;27(1):23. doi: 10.1186/s12998-019-0244-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Bronfort G, Haas M, Evans R, Leininger B, Triano J. Effectiveness of manual therapies: the UK evidence report. Chiropr Osteopat. 2010;18(1):3. doi: 10.1186/1746-1340-18-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Rubinstein SM, de Zoete A, van Middelkoop M, Assendelft WJJ, de Boer MR, van Tulder MW. Benefits and harms of spinal manipulative therapy for the treatment of chronic low back pain: systematic review and meta-analysis of randomised controlled trials. BMJ. 2019;364:l689. doi: 10.1136/bmj.l689. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Coulter ID, Crawford C, Vernon H, Hurwitz EL, Khorsan R, Booth MS, et al. Manipulation and mobilization for treating Chronic nonspecific Neck Pain: a systematic review and Meta-analysis for an appropriateness panel. Pain Physician. 2019;22(2):E55–70. doi: 10.36076/ppj/2019.22.E55. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Arksey H, O’Malley L. Scoping studies: towards a methodological framework. Int J Soc Res Methodol. 2005;8:19–32. doi: 10.1080/1364557032000119616. [DOI] [Google Scholar]
  • 20.Tricco AC, Lillie E, Zarin W, O’Brien KK, Colquhoun H, Levac D, et al. PRISMA Extension for scoping reviews (PRISMA-ScR): Checklist and Explanation. Ann Intern Med. 2018;169(7):467–73. doi: 10.7326/M18-0850. [DOI] [PubMed] [Google Scholar]
  • 21.Cooke A, Smith D, Booth A, Beyond PICO. The SPIDER tool for qualitative evidence synthesis. Qual Health Res. 2012;22(10):1435–43. doi: 10.1177/1049732312452938. [DOI] [PubMed] [Google Scholar]
  • 22.Ouzzani M, Hammady H, Fedorowicz Z, Elmagarmid A. Rayyan-a web and mobile app for systematic reviews. Syst Rev. 2016;5(1):210. doi: 10.1186/s13643-016-0384-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lardon A, Pasquier M, Audo Y, Barbier-Cazorla F, Descarreaux M. Effects of an 8-week physical exercise program on spinal manipulation biomechanical parameters in a group of 1st-year chiropractic students. J Chiropr Educ. 2019;33(2):118–24. doi: 10.7899/JCE-18-15. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Brennan PC, Triano JJ, McGregor M, Kokjohn K, Hondras MA, Brennan DC. Enhanced neutrophil respiratory burst as a biological marker for manipulation forces: duration of the effect and association with substance P and tumor necrosis factor. J Manipulative Physiol Ther. 1992;15(2):83–9. [PubMed] [Google Scholar]
  • 25.Groeneweg R, Rubinstein SM, Oostendorp RAB, Ostelo RWJG, van Tulder MW. Guideline for reporting interventions on spinal manipulative therapy: Consensus on Interventions reporting Criteria list for spinal manipulative therapy (CIRCLe SMT) J Manipulative Physiol Ther. 2017;40(2):61–70. doi: 10.1016/j.jmpt.2016.10.013. [DOI] [PubMed] [Google Scholar]
  • 26.Price J, Rushton A, Tyros V, Heneghan NR. Expert consensus on the important chronic non-specific neck pain motor control and segmental exercise and dosage variables: an international e-Delphi study. PLoS ONE. 2021;16(7):e0253523. doi: 10.1371/journal.pone.0253523. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Hoffmann TC, Glasziou PP, Boutron I, Milne R, Perera R, Moher D, et al. Better reporting of interventions: template for intervention description and replication (TIDieR) checklist and guide. BMJ. 2014;348:g1687. doi: 10.1136/bmj.g1687. [DOI] [PubMed] [Google Scholar]
  • 28.Mercier MA, Rousseau P, Funabashi M, Descarreaux M, Pagé I. Devices Used to Measure Force-Time Characteristics of Spinal Manipulations and Mobilizations: A Mixed-Methods Scoping Review on Metrologic Properties and Factors Influencing Use. Front Pain Res [Internet]. 2021;2. Available from: https://www.frontiersin.org/articles/10.3389/fpain.2021.755877 [DOI] [PMC free article] [PubMed]
  • 29.Kirstukas SJ, Backman JA. Physician-applied contact pressure and table force response during unilateral thoracic manipulation. J Manipulative Physiol Ther. 1999;22(5):269–79. doi: 10.1016/S0161-4754(99)70059-X. [DOI] [PubMed] [Google Scholar]
  • 30.McCarthy PW, Prudden M, Byfield D. An investigation of the manipulative parameters of postgraduate chiropractors. Eur J Chiropr. 2002;50(1):15–25. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Material 1 (22.4KB, docx)
Supplementary Material 2 (22.8KB, docx)
Supplementary Material 3 (67.8KB, docx)

Data Availability Statement

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.


Articles from Chiropractic & Manual Therapies are provided here courtesy of BMC