Abstract
Background
Placenta accreta spectrum (PAS) is a rare, life-threatening complication of pregnancy. Predicting PAS severity is critical to individualise care planning for the birth. We aim to explore whether radiomic analysis of T2-weighted magnetic resonance imaging (MRI) can predict severe cases by distinguishing between histopathological subtypes antenatally.
Methods
This was a bi-centre retrospective analysis of a prospective cohort study conducted between 2018 and 2022. Women who underwent MRI during pregnancy and had histological confirmation of PAS were included. Radiomic features were extracted from T2-weighted images. Univariate regression and multivariate analyses were performed to build predictive models to differentiate between non-invasive (International Federation of Gynecology and Obstetrics [FIGO] grade 1 or 2) and invasive (FIGO grade 3) PAS using R software. Prediction performance was assessed based on several metrics including sensitivity, specificity, accuracy and area under the curve (AUC) at receiver operating characteristic analysis.
Results
Forty-one women met the inclusion criteria. At univariate analysis, 0.64 sensitivity (95% confidence interval [CI] 0.0−1.00), specificity 0.93 (0.38−1.0), 0.58 accuracy (0.37−0.78) and 0.77 AUC (0.56−.097) was achieved for predicting severe FIGO grade 3 PAS. Using a multivariate approach, a support vector machine model yielded 0.30 sensitivity (95% CI 0.18−1.0]), 0.74 specificity (0.38−1.00), 0.58 accuracy (0.40−0.82), and 0.53 AUC (0.40−0.85).
Conclusion
Our results demonstrate a predictive potential of this machine learning pipeline for classifying severe PAS cases.
Relevance statement
This study demonstrates the potential use of radiomics from MR images to identify severe cases of placenta accreta spectrum antenatally.
Key points
• Identifying severe cases of placenta accreta spectrum from imaging is challenging.
• We present a methodological approach for radiomics-based prediction of placenta accreta.
• We report certain radiomic features are able to predict severe PAS subtypes.
• Identifying severe PAS subtypes ensures safe and individualised care planning for birth.
Graphical Abstract
Supplementary Information
The online version contains supplementary material available at 10.1186/s41747-023-00369-2.
Keywords: Machine learning, Magnetic resonance imaging, Placenta accreta, Pregnancy, Radiomics
Background
Placenta accreta spectrum (PAS) is a rare, life-threatening complication of pregnancy where the placenta is abnormally attached to the uterine wall [1]. PAS is classified into three grades by the International Federation of Gynecology and Obstetrics (FIGO) [2], with FIGO grade 3 being the most severe. Up to 50% of cases worldwide are undiagnosed during pregnancy, which is associated with significantly poorer maternal and fetal outcomes [3]. Predicting disease severity antenatally remains a major challenge. There is no consensus internationally on optimal management, with variations in many aspects of clinical care [4].
Ultrasound and magnetic resonance imaging (MRI) are the imaging modalities of choice for diagnosing PAS antenatally [5, 6]. While PAS is usually first suspected from an ultrasound assessment, MRI plays an important role, such as for surgical planning and in the assessment of posterior or lateral defects [5, 7, 8]. Furthermore, some centres routinely perform MRI when ultrasound signs of PAS are seen [9]. However, the diagnostic accuracy of MRI is highly dependent on reader expertise and can incorrectly classify cases in up to 30% of cases [10].
Radiomics is a quantitative approach to medical imaging, where potential image biomarkers are extracted from images [11]. Several studies have applied radiomics to MR images in PAS and found radiomic features were useful in aiding diagnosis and predicting clinical outcomes such as massive obstetric haemorrhage [12, 13]. These were summarised in a recent systematic review, which included 10 studies [14]. The review highlighted the varying methodological quality of the radiomics PAS studies to date [14]. Many were limited by the significant heterogeneity in how PAS was defined, with only two studies reporting on histological data, which is considered the reference standard in diagnosing PAS [14, 15]. In one of the largest studies included, over 70% of PAS cases had neither of the two most important and frequent predisposing risk factors [16], which are a prior Caesarean section and placenta previa [17]. Hence it is unclear what clinical or histopathological criteria were used to define PAS in many of these studies [14]. Furthermore, a lack of standardised methodology is an important limitation of all radiomics studies and remains a major challenge in the field [18].
Therefore, the current literature is limited by the lack of standardised definitions for PAS and the varying quality of the radiomic methodology. We propose a methodological approach for image segmentation and a radiomic workflow for predicting severe FIGO grade 3 PAS. We describe the location and severity of PAS using standardised definitions as they are currently understood [2, 15], use a standardised methodology for radiomic feature extraction [19], and provide an open source code for each step, with adherence to the Radiomics Quality Score [20] as much as was feasible. We report our results from a pilot test dataset.
Methods
Study population
Ethical approval was obtained from the National Maternity Hospital, Dublin (EC30.2018) and Rotunda Hospital Dublin ethics committees (RAG 2019–10). Participants provided written, informed consent. Image data was obtained prospectively, and retrospectively analysed as part of a two-centre cohort from between January 2018 to October 2022. Inclusion criteria were: consecutive participants who underwent MRI for suspicion of PAS based on ultrasound assessment [6], intraoperative findings at the time of laparotomy found clinical features of PAS as defined by the FIGO classification [2], and examination by a specialist perinatal histopathologist (> 10 years of experience) who confirmed PAS on histology [15]. Figure 1 shows an example of an included PAS case on MRI, with corresponding gross and microscopic histopathology images. We excluded cases with MRI performed for suspicion of PAS, without clinical evidence of PAS intraoperatively or histopathological examination confirming the diagnosis, or those who gave birth outside of a participating centre. Placenta previa was defined as the placenta completely covering the internal cervical os on transvaginal ultrasound beyond 20 weeks of gestation [21].
PAS multidisciplinary team management
All participants in this study were cared for by a multidisciplinary PAS specialist team. Antenatal imaging consists of ultrasound, performed by fetal-medicine specialists using both transabdominal and transvaginal ultrasound, and MRI, read and reported by specialist radiologists [22] (T.G., with over 15 years of experience; D.B., with over 20 years of experience). Timing of elective delivery was between week 34 and week 36 of gestation, following a standardised surgical approach [23]. Cases confirmed intraoperatively as PAS undergo either myometrial resection or Caesarean hysterectomy.
MRI protocol
Patients were scanned on a 1.5-T scanner (Optima 450W MR, General Electric Healthcare, Waukesha, USA) (n = 40) or a 1.5-T scanner (MAGNETOM Sola, Siemens Healthineers, Erlangen, Germany) (n = 7) using a T2-weighted sagittal two-dimensional balanced steady-state free precession, b-SSFP, sequence with a slice thickness of 4 mm, slice spacing of 1 mm, and a field of view of 38 cm at both imaging sites. The MRI acquisition protocol of the placenta for the assessment of PAS performed at site 1 was previously described [24, 25].
Radiomics processing
The workflow for radiomics processing is summarised in Fig. 2. The code for these steps and methodology used is publicly available in the following repository: https://github.com/helenabartels91/PASRadiomics.git
Image segmentation
Sagittal planes were used for segmentation as this allows an optimal view of the bladder, placental location and the cervix, and the relationship of these key organs of interest to each other, including the area of placental adherence or invasion. Images were manually segmented on multiple representative slices with regions of interest (ROIs) by three independent investigators (H.B., D.B., R.M., with 4 over 20 and 6 years of experience). Investigators were aware of the purpose of the study but were blinded to the results of other imaging, or final intraoperative or histopathological outcomes. The segmentation protocol was informed by a previous work where ROIs of the placenta proximal and remote to the prior Caesarean section scar showed significant differences in the distribution of radiomic features, which were associated with undergoing caesarean hysterectomy for PAS [13]. Furthermore, we have previously reported a linear relationship between the distance from the internal cervical os to the most proximal part of the PAS defect as seen on MRI and estimated blood loss, with defects closer to the internal os associated with significantly higher blood loss [26]. Hence, we generated two placental ROIs, based on proximity to the area of adherence or invasive (inferior placental ROI, close to internal cervical os) and remote from this area (superior placental ROI). The image segmentation protocol is included in Supplementary materials.
Feature extraction
Radiomic feature extraction was performed using PyRadiomics [11], resulting in 106 radiomic features from 6 feature families including shape, first-order (histogram-based) and second-order (Gray Level Cooccurrence Matrix, Gray Level Run Length Matrix, Gray Level Size Zone Matrix, and Gray Level Dependence Matrix) features, from the original image. Feature families and specific features used in this work are mathematically defined as per the PyRadiomics framework, as previously described (https://pyradiomics.readthedocs.io/en/latest/features.html). Separately, feature extraction was performed using convolutional image filters such as Laplacian of Gaussian (with 5 sigma levels: 1 level of wavelet decompositions resulting in eight derived images and images derived using square, square root, logarithm and exponential filters) resulting in another 1,714 radiomic features being extracted, for a total 1,820 radiomic features extracted [21]. The preprocessing steps are outlined in the parameter file available in the GitHub repository [27].
Feature selection
Optimal radiomic features were selected using an unsupervised machine learning approach (Fig. 2) to identify a subset with strong predictive potential prior to model building. A correlation filter was applied to all the 1,820 extracted radiomic features, eliminating features with a Pearson correlation > 0.80 in absolute value. A minimum variance filter, Near Zero Variance, was applied to the remaining features to exclude any noninformative variables. As radiomic features are susceptible to variation between different MRI scanners [28], the distributions of the remaining features from each of the two MRI scanners used in this study were compared by way of a two-sample, two-sided Mann–Whitney U test [29] at the 5% significance level; p values from these multiple tests were corrected for false discovery rate (FDR) [30]. Features with high cross-scanner discrepancies, defined as an adjusted p value < 0.05, were removed. A test–retest analysis was performed on the remainder set of features to evaluate stability of the radiomic feature quantitation with respect to inter-reader variability for a subset of 22 cases; the minimum Pearson correlation between features extracted from the segmentations performed by different readers on the same cases was 0.75, and the 5th percentile of Pearson correlations was 0.969. For intraclass correlation (ICC), similar findings were found with a 5th ICC percentile of 0.965.
Predictive modelling
The following clinical variables were included for modelling: body mass index, maternal age, and the number of prior Caesarean sections. Differences between clinical variables and radiomic features were compared between FIGO grade 1–2 and grade 3 cases using a two-sample, two-sided Mann–Whitney U test. After p value adjustment for FDR, there were no significant associations, with a smallest p value of 0.228.
Univariate logistic regression models trained using bootstrapping, and tested on the out-of-bag bootstrap points, were used to identify the best performing radiomic features. The performance of univariate models was assessed on the basis of the area under curve (AUC) at receiver operating characteristic (ROC) analysis and of overall prediction accuracy. Four multivariate classifiers were trained for PAS prediction: least absolute shrinkage and selection operator (LASSO), random forest (RF), k-nearest neighbour, and support vector machine (SVM) [31]. Their performance was assessed using calibration curves, ROC analysis, sensitivity, specificity and accuracy. As three of these models (namely LASSO, RF, and SVM) include a built-in feature selection mechanism, final predictive feature sets were also analysed from these modelling pipelines.
One-sided, two-sample Mann–Whitney U tests were carried out to compare performance metrics between univariate and multivariate models at the 5% significance level after FDR correction. These tests were unpaired since the models were bootstrapped separately, each using different resamples.
Variable importance can be measured for these multivariate models to determine the extent of the contribution from each feature, and were thus analysed. In complement to these metrics, Principal component analysis (PCA), a dimensionality reduction technique used to explain the total variation (i.e., information) in the dataset along principal components arranged in decreasing order of relevance [32], was further performed to explore how the final feature sets summarised the overall information available for analysis. Biplots of the PCA-based projections of the final predictive feature sets were considered to assess the level of redundancy present in the latter, and possibly identify key features driving the prediction.
Statistical software
Statistical analysis for this study was performed in RStudio (version 4.2.2 [33]). Feature reduction and model building were performed using R with the caret [34], pROC [35], and corrplot [36] packages.
Results
Forty-one participants met inclusion criteria (34 from site 1, 7 from site 2), including 18 FIGO grade 1–2 and 23 FIGO grade 3 PAS cases. Participants had a median age of 37.0 years (interquartile range 34.0 × 40.0 years) and were predominantly of white Irish ethnicity (Table 1). All women had at least one prior Caesarean section, and 29/41 (70.7%) underwent caesarean hysterectomy.
Table 1.
FIGO grade 1–2 (n = 18) | FIGO grade 3 (n = 23) | |
---|---|---|
Age (years) | 36.0 (34.0–39.75) | 39.0 (37.2–42.7) |
Body mass index (kg/m2) | 25.2 (23.4–29.3) | 25.7 (23.0–30.1) |
Parity | 2 (1–3) | 2 (1–2.5) |
No of previous Caesarean section | 1 (1–2) | 2 (1–3) |
Gestation at MRI (weeks + days) | 29 + 0 (27 + 2 − 32 + 3) | 28 + 1 (27 + 0–31 + 0) |
Placental location on MRI, n (%) | ||
Placenta previa | 18 (100.0) | 22 (95.6) |
Anterior placenta previa | 16 (88.0) | 22 (95.6) |
Posterior placenta previa | 2 (12.0) | 0 (0.0) |
Elective delivery, n (%) | 30 (75.0) | 7 (100.0) |
Estimated blood loss (mL) | 1,100 (735–3,250) | 1,600 (1,100–5,800) |
Red cell concentrate transfusion, n (%) | 6 (33.3) | 10 (43.5) |
Surgical outcome | ||
Caesarean hysterectomy, n (%) | 7 (38.9) | 22 (95.7) |
Uterine conservationa (%) | 11 (61.6) | 1 (4.3) |
FIGO histological grade, n (%) | ||
1 | 4 (22.2) | 0 (0.0) |
2 | 14 (77.8) | 0 (0.0) |
3 | 0 (0.0) | 23 (100) |
Data are given in median (interquartile interval) unless otherwise stated
aUterine conservation for the PAS group were cases who underwent myometrial resection. FIGO International Federation of Gynecology and Obstetrics
The feature filtering steps of correlation filter and Near Zero Variance yielded a subset of 47 features from the original images, and a subset of 225 features when including any features from either original and pre-filtered images. Following removal of features with high cross scanner discrepancies, a final feature set of 204 features were selected.
Univariate analyses
The radiomic features identified by univariate analysis as most strongly associated with FIGO grade 3 PAS are shown in Fig. 3. Clinical features included in the models were not of high importance, with only the number of previous Caesarean section included in the top ten accuracies or AUC from univariate logistic regression (Fig. 3).
From the superior placental ROI, exponential_glszm_SizeZoneNonUniformityNormalized yielded the highest bootstrapped accuracy of 0.58 (95% confidence interval [CI] 0.39−0.77) and the highest AUC was 0.77 (0.56−0.97]) from log.sigma.5.0.mm.3D_firstorder_90Percentile. The highest sensitivity was wavelet.HHH_glszm_GrayLevelVarianceof 0.64 (0.0−1.00]), while specificity was 0.88 (0.40−1.00]) from lbp.3D.m2_firstorder_Range. For the inferior placental ROI, squareroot_glszm_GrayLevelNonUniformity yielded the highest accuracy of 0.58 (0.37−0.78) and a highest AUC 0.75 (0.56−0.94) from log.sigma.2.0.mm.3D_firstorder_Maximum. A sensitivity of 0.62 (95% CI: [0.61; 1]) was achieved from wavelet.HHH_firstorder_Median, and a highest specificity of 0.93 (0.38−1.00]) from square_firstorder_Minimum (Fig. 3b).
At univariate analysis, the inferior and superior placental ROIs yielded similar levels of performance (Fig. 3a). Subsets of individual radiomic features with high specificity were found in both regions, while sensitivity was poorer for both. The radiomic profiles of inferior and placental regions were, however, different with little correlation between them (Pearson ρ−0.26 and + 0.31). Thirty per cent of features were significantly different between the regions (19.4% were significantly greater in the superior ROI, and 11.6% in the inferior ROI) at the 5% significance level based on one-sided, two-sample Mann–Whitney U tests. These results indicate that high specificity was facilitated by different radiomic profiles in the inferior and superior placental areas.
Multivariate predictive modelling
For classification based on the four multivariate models (LASSO, RF, kNN, and SVM), calibration curves demonstrated reasonable agreement between the predicted and observed rates of FIGO grade 3 PAS, indicating the models estimate the probability of PAS appropriately both for FIGO grade 3 and non-grade 3 cases (Fig. 4). Models had a similar performance overall for predicting FIGO grade 3 PAS, with all models having a ROC of above 50% and specificity above 60% (Fig. 5a, b). Comparing the inferior and superior placental ROIs, RF had a significantly higher accuracy in the superior compared to the inferior placental ROI (Mann–Whitney U test, p = 0.003), while kNN had a significantly greater specificity in the inferior region versus superior region (Mann–Whitney U test, p = 0.001). There were no other significant differences between model performance between the inferior and superior ROIs (all p values > 0.05, Supplementary Figure S1).
The variables of highest importance for multivariate modelling are shown in Fig. 5c; radiomic features were ranked as highest importance, with no clinical features ranked as important for modelling. For multivariate models, radiomic features with image filters applied were selected at higher frequency than those from the original image, with no radiomic feature from the original image feature ranked in the top 20 predictive features for either the inferior and superior placental ROIs for predicting severe FIGO grade 3 PAS. Features from various families were included in the final feature sets for prediction, including first-order, Gray Level Run Length Matrix, Gray Level Size Zone Matrix, and Gray Level Dependence Matrix.
PCA was then performed to further explore the structure of final feature sets obtained from each model (Fig. 6), in particular to analyse how the final predictors tend to group up into separate predictive clusters. To do this, the distribution in the PCA domain of all features used for model training was first analysed using k-means clustering [31]. Then, the final feature sets obtained from each model were mapped to these clusters in order to identify high-predictive clusters of features, and relevant features within these specific clusters. From this analysis, it was observed that all models contained the first-order mean level from the wavelet HLL-filtered image in their final feature subset. k-nearest neighbour and SVM selected the same feature subsets, due to the discretisation method used in evaluating variable importance for these two models, which included only one clinical variable, i.e., the number of prior Caesarean sections. Both these models tended to use more information from some of the clusters in particular, i.e., groups of predictors with a high level of information overlap.
Discussion
We presented a methodological approach and results from a bi-centre study for radiomics-based prediction of disease severity for PAS. This work contributes a radiomics study employing standardised clinical-histopathological descriptions for PAS [2, 15]. Furthermore, radiomic feature extraction was performed using well described methods, with the steps of feature reduction and predictive modelling provided as open source code. We found a high specificity of radiomics-based prediction for severe FIGO grade 3 PAS cases.
Our outcome for predictive modelling was histopathological diagnosis, the gold standard for diagnosis of PAS [2, 15]. Previous studies have used radiomic features to predict clinical outcomes such as undergoing caesarean hysterectomy and blood loss [13, 37], however, we opted to build our models using only the histopathological FIGO grading of PAS severity. This was because clinical outcomes, such as performing a caesarean hysterectomy, reflect the local clinical practice rather than the suspected severity of disease from antenatal imaging. For example, centres practicing conservative management with leaving the placenta in situ may have much lower hysterectomy rates compared to centres where hysterectomy is routinely performed for PAS cases [22, 38]. Similarly, using haemorrhage as an outcome for predicting modelling is limited as blood loss measurement is highly heterogenous and often inaccurate, hence complicating comparisons between studies using this as an outcome [39, 40]. Moreover, clinical outcomes are often not related to disease severity, but to other factors such as emergency delivery, as well as clinician consideration of the woman’s parity, her preferences and future fertility plans [3, 41]. Hence, we choose to develop our models on a reproducible histopathological outcome reflective of disease severity.
We found radiomic features from both placental ROIs had an overall similar performance. We hypothesised that radiomic features from the inferior placental ROI would be more predictive of FIGO grade 3 PAS as this is the area where abnormal uterine remodelling from a prior Caesarean section has resulted in abnormal placentation [42]. Our results suggests there are placental changes beyond the myometrial-bladder interface, which were useful for classifying severe PAS cases. Well-described MR imaging features, such as abnormal vascularisation of the placental bed and focal exophytic mass, are signs of severe PAS; they are usually seen at the level of the bladder, and are therefore included in the inferior placental ROI [5]. MRI features such as placental heterogeneity and T2-dark bands are seen throughout the whole placenta. Other features of severe PAS, such as intraplacental fetal vessel diameter, are also evident throughout the placenta [43]. These appear as darkened areas deep in the placenta. Hence, it follows that the most predictive features from the superior placental ROI were textural features describing differences in homogeneity and grey level values. This suggests that in PAS there may be textural changes throughout the whole placenta that were useful for our modelling.
We report the use of image pre-processing and use of pre-processing image filters resulted in significantly better model performance compared to use of the original image features only. There is currently no consensus on how to perform these steps for MR images in radiomics, and is one of the many open challenges in radiomic processing [18, 44]. Our results support the finding of previous radiomic studies in PAS, where radiomic features from image filters were more predictive and had higher diagnostic accuracy than those from the original image [45, 46]. Previously, some studies reported the use of pre-processing image filters was shown to improve predictive performance of models [47, 48]. However, when datasets are small, limiting the analysis to radiomic features from the original image only showed similar results to when all radiomic features with image filters were included [47]. Here we also performed predictions using both the original image features and using all features from image filters. However, we found that features from the pre-processed images had better predictive potential.
Initiatives such as the RQS [20] and Image Biomarker Standardisation Initiative [49] attempt to harmonise radiomic studies and produce results which can be validated and applied to clinical settings. Few radiomic studies to date have included a RQS in their work [20], and many when assessed externally score poorly, with the studies in the systematic review on PAS radiomics having a median RQS score of 23% [14].
The RQS of this study was 38% (see Supplementary materials), however, this score was developed to assess the quality of oncologic radiomics studies and not studies exploring conditions such as PAS. This study, as with many studies not assessing oncologic data, is penalised by the RQS in a number of areas. Firstly, image data is not available at multiple time points. In oncology, the purpose of repeat imaging is to assess response to a treatment, such as chemotherapy. In PAS, the condition is limited to a distinct period of time—pregnancy—and once the pregnancy is completed and the placenta removed, the condition can be considered as “treated”. Hence, unlike in cancer care, there is no indication to repeat imaging to assess treatment response.
Secondly, points are assigned for using open source images, segmentations and code. To our knowledge, these are not currently available for PAS. Any future such dataset would need to ensure the inclusion criteria are as described by the FIGO classification. For segmentations, while automated segmentations may be considered the ideal approach as it minimises the inter-observability between segmentations, the applicability of trained algorithms to new datasets is currently limited and often results in failure of accurate segmentations [18]. Attempts to limit inter-observer variability in this study included calculation of the ICC between readers for a subset of segmentations, a clearly defined segmentation protocol and three investigators independently performing segmentations with cross-reference. If a disagreement arose, the third investigator acted as mediator.
PAS remains a rare complication of pregnancy, however the incidence is increasing as a result of the rise in the Caesarean section rate [50]. Ultrasound and MRI both rely heavily on reader expertise of the clinician [5, 10]. In this study, radiomic features had a reasonable sensitivity for identifying severe FIGO grade 3 cases on univariate analysis, and a high specificity. This demonstrates the clinical potential of using radiomics to detect and rule out severe PAS. By identifying severe PAS subtypes, interventions associated with additional morbidity, such as elective preterm delivery and interventional radiology techniques, may be reserved for these cases. While these findings will require validation in an external dataset, this work supports the potential use of radiomics in predicting disease severity in PAS.
This study has several limitations. Firstly, the sample size is small. Nonetheless, results from our pilot dataset demonstrated that radiomic features predicted severe PAS. Efforts to increase our sample size were employed, by using data available from another centre. As a result of the small sample size, it is not surprising that multivariate models showed a drop in performance compared to univariate analysis given the loss of statistical power with a small N:P ratio. Some important MRI features of PAS such as myometrial thinning and interruption of the bladder wall will not be captured by the ROIs presented here, which include only the placenta. However, there was consensus that there would be limited accuracy in delineating the myometrium which in many cases will be thinned to less than 1 mm or not be visible [5]; hence, only the placenta was segmented for this work. Although segmentations were performed manually by three readers, radiomic features were very stable across the readers as demonstrated by high Pearson correlation on test–retest analyses.
In summary, we present a suggested methodology for MRI segmentation and radiomic processing for predicting disease severity in PAS. Despite the restrictive size of the dataset, we found radiomic features have the potential predict severe FIGO grade 3 PAS cases. Radiomics to predict disease severity may assist clinicians in individualising care for women with PAS. Future studies can implement the prediction model using larger datasets to validate and improve upon the results reported here.
Supplementary Information
Abbreviations
- AUC
Area under the curve
- CI
Confidence interval
- FDR
False discovery rate
- FIGO
International Federation of Obstetrics and Gynaecology
- ICC
Intraclass correlation
- LASSO
Least absolute shrinkage and selection operator
- MRI
Magnetic resonance imaging
- PAS
Placenta accreta spectrum
- PCA
Principal component analysis
- RF
Random forest
- ROC
Receiver operating characteristic
- ROI
Region of interest
- RQS
Radiomics Quality Score
- SVM
Support vector machine
Authors’ contributions
Conceptualisation: Helena C Bartels, Jim O’Doherty, David P Brophy, Roisin MacDermott, David Atallah, Donal J Brennan, Kathleen M Curran. Methodology: Helena C Bartels, Jim O’Doherty, Eric Wolsztynski, David P Brophy, Roisin MacDermott, David Atallah, Souha Saliba, Constance Young, Paul Downey, Jennifer Donnelly, Tony Geoghegan, Donal J Brennan, Kathleen M Curran. Software: Helena C Bartels, Eric Wolsztynski, Jim O’Doherty, Kathleen Curran. Formal analysis: Helena C Bartels, Jim O’Doherty, Eric Wolsztynski, David P Brophy, Roisin MacDermott, David Atallah, Souha Saliba, Constance Young, Donal J Brennan, Kathleen M Curran. Data curation: Helena C Bartels, David P Brophy, Roisin MacDermott, David Atallah, Souha Saliba, Constance Young, Paul Downey, Jennifer Donnelly, Tony Geoghegan, Donal J Brennan, Kathleen M Curran. Writing—original draft: Helena C Bartels, Jim O’Doherty, Eric Wolsztynski, Kathleen M Curran. Writing (review, editing): Helena C Bartels, Jim O’Doherty, Eric Wolsztynski, David P Brophy, Roisin MacDermott, David Atallah, Souha Saliba, Constance Young, Paul Downey, Jennifer Donnelly, Tony Geoghegan, Donal J Brennan, Kathleen M Curran. Supervision: Jim O’Doherty, Donal J Brennan, Kathleen M Curran. Funding acquisition: Helena C Bartels, Donal J Brennan. All authors read and approved the final manuscript.
Funding
This research was funded by the Medical Fund at the National Maternity Hospital, Dublin, Ireland. Eric Wolsztynski: funding from Science Foundation Ireland under grant number 12/RC/2289-P2, co-funded under the European Regional Development Fund.
Availability of data and materials
The code used for the methods presented in this manuscript are provided as open source in a public repository. The image data used for analysis is not publicly available.
Declarations
Ethics approval and consent to participate
Ethical approval was obtained from the National Maternity Hospital (EC30.2018) and Rotunda Hospital ethics committees (RAG 2019–10). Written informed consent was obtained from all subjects (patients) in this study.
Consent for publication
Not applicable.
Competing interests
Jim O’Doherty is an employee of Siemens Medical Solutions (which did not sponsor or fund this study). The remaining authors have no conflicts of interest to declare.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Change history
11/22/2023
A Correction to this paper has been published: 10.1186/s41747-023-00397-y
Contributor Information
Helena C. Bartels, Email: helenabartels91@gmail.com
Kathleen M. Curran, Email: kathleen.curran@ucd.ie
References
- 1.Bartels HC, Postle JD, Downey P, Brennan DJ. Placenta accreta spectrum: a review of pathology, molecular biology, and biomarkers. Dis Markers. 2018;2018:1507674. doi: 10.1155/2018/1507674. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Jauniaux E, Ayres-de-Campos D, Langhoff-Roos J, Fox KA, Collins S. FIGO classification for the clinical diagnosis of placenta accreta spectrum disorders. Int J Gynaecol Obstet. 2019;146:20–24. doi: 10.1002/ijgo.12761. [DOI] [PubMed] [Google Scholar]
- 3.Bartels HC, Rogers AC, O'Brien D, McVey R, Walsh J, Brennan DJ. Association of implementing a multidisciplinary team approach in the management of morbidly adherent placenta with maternal morbidity and mortality. Obstet Gynecol. 2018;132:1167–1176. doi: 10.1097/aog.0000000000002865. [DOI] [PubMed] [Google Scholar]
- 4.Einerson BD, Silver RM. Multidisciplinary teams in the management of placenta accreta spectrum disorders. Curr Obstet Gynecol Rep Rep. 2019;8:80–85. doi: 10.1007/s13669-019-00264-x. [DOI] [Google Scholar]
- 5.Jha P, Pōder L, Bourgioti C, et al. Society of Abdominal Radiology (SAR) and European Society of Urogenital Radiology (ESUR) joint consensus statement for MR imaging of placenta accreta spectrum disorders. Eur Radiol. 2020;30:2604–2615. doi: 10.1007/s00330-019-06617-7. [DOI] [PubMed] [Google Scholar]
- 6.Collins SL, Ashcroft A, Braun T, et al. Proposal for standardized ultrasound descriptors of abnormally invasive placenta (AIP) Ultrasound Obstet Gynecol. 2016;47:271–275. doi: 10.1002/uog.14952. [DOI] [PubMed] [Google Scholar]
- 7.Tinari S, Buca D, Cali G, et al. Risk factors, histopathology and diagnostic accuracy in posterior placenta accreta spectrum disorders: systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2021;57:903–909. doi: 10.1002/uog.22183. [DOI] [PubMed] [Google Scholar]
- 8.Palacios-Jaraquemada JM, Fiorillo A, Hamer J, Martínez M, Bruno C. Placenta accreta spectrum: a hysterectomy can be prevented in almost 80% of cases using a resective-reconstructive technique. J Maternal-Fetal Neonatal Med. 2022;35:275–282. doi: 10.1080/14767058.2020.1716715. [DOI] [PubMed] [Google Scholar]
- 9.Palacios Jaraquemada JM, Bruno CH. Magnetic resonance imaging in 300 cases of placenta accreta: surgical correlation of new findings. Acta Obstet Gynecol Scand. 2005;84:716–724. doi: 10.1111/j.0001-6349.2005.00832.x. [DOI] [PubMed] [Google Scholar]
- 10.Einerson BD, Rodriguez CE, Kennedy AM, Woodward PJ, Donnelly MA, Silver RM. Magnetic resonance imaging is often misleading when used as an adjunct to ultrasound in the management of placenta accreta spectrum disorders. Am J Obstet Gynecol. 2018;218:618.e611–618.e617. doi: 10.1016/j.ajog.2018.03.013. [DOI] [PubMed] [Google Scholar]
- 11.Lambin P, Leijenaar RTH, Deist TM, et al. Radiomics: the bridge between medical imaging and personalized medicine. Nat Rev Clin Oncol. 2017;14:749–762. doi: 10.1038/nrclinonc.2017.141. [DOI] [PubMed] [Google Scholar]
- 12.Peng L, Zhang X, Liu J et al (2022) MRI-radiomics-clinical-based nomogram for prenatal prediction of the placenta accreta spectrum disorders. Eur Radiol. 10.1007/s00330-022-08821-410.1007/s00330-022-08821-4. [DOI] [PubMed]
- 13.Do QN, Lewis MA, Xi Y, et al. MRI of the placenta accreta spectrum (PAS) disorder: radiomics analysis correlates with surgical and pathological outcome. J Magn Reson Imaging. 2020;51:936–946. doi: 10.1002/jmri.26883. [DOI] [PubMed] [Google Scholar]
- 14.Stanzione A, Verde F, Cuocolo R, et al. Placenta accreta spectrum disorders and radiomics: systematic review and quality appraisal. Eur J Radiol. 2022;155:110497. doi: 10.1016/j.ejrad.2022.110497. [DOI] [PubMed] [Google Scholar]
- 15.Hecht JL, Baergen R, Ernst LM, et al. Classification and reporting guidelines for the pathology diagnosis of placenta accreta spectrum (PAS) disorders: recommendations from an expert panel. Mod Pathol. 2020;33:2382–2396. doi: 10.1038/s41379-020-0569-1. [DOI] [PubMed] [Google Scholar]
- 16.Ye Z, Xuan R, Ouyang M, Wang Y, Xu J, Jin W. Prediction of placenta accreta spectrum by combining deep learning and radiomics using T2WI: a multicenter study. Abdom Radiol (NY) 2022;47:4205–4218. doi: 10.1007/s00261-022-03673-4. [DOI] [PubMed] [Google Scholar]
- 17.Collins SL, Alemdar B, van Beekhuizen HJ, et al. Evidence-based guidelines for the management of abnormally invasive placenta: recommendations from the International Society for Abnormally Invasive Placenta. Am J Obstet Gynecol. 2019;220:511–526. doi: 10.1016/j.ajog.2019.02.054. [DOI] [PubMed] [Google Scholar]
- 18.van Timmeren JE, Cester D, Tanadini-Lang S, Alkadhi H, Baessler B. Radiomics in medical imaging-"how-to" guide and critical reflection. Insights Imaging. 2020;11:91. doi: 10.1186/s13244-020-00887-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.van Griethuysen JJM, Fedorov A, Parmar C, et al. Computational radiomics system to decode the radiographic phenotype. Cancer Res. 2017;77:e104–e107. doi: 10.1158/0008-5472.Can-17-0339. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Park JE, Kim HS, Kim D, et al. A systematic review reporting quality of radiomics research in neuro-oncology: toward clinical utility and quality improvement using high-dimensional imaging features. BMC Cancer. 2020;20:29. doi: 10.1186/s12885-019-6504-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Jauniaux E, Alfirevic Z, Bhide AG, et al. Placenta praevia and placenta accreta: diagnosis and management: green-top guideline No. 27a. BJOG. 2019;126:e1–e48. doi: 10.1111/1471-0528.15306. [DOI] [PubMed] [Google Scholar]
- 22.Bartels HC, Mulligan KM, Craven S, et al. Maternal morbidity in placenta accreta spectrum following introduction of a multi-disciplinary service compared to standard care: an Irish perspective. Ir J Med Sci. 2021;190:1451–1457. doi: 10.1007/s11845-020-02473-3. [DOI] [PubMed] [Google Scholar]
- 23.Brennan DJ, Schulze B, Chetty N, et al. Surgical management of abnormally invasive placenta: a retrospective cohort study demonstrating the benefits of a standardized operative approach. Acta Obstet Gynecol Scand. 2015;94:1380–1386. doi: 10.1111/aogs.12768. [DOI] [PubMed] [Google Scholar]
- 24.Brown BP, Meyers ML. Placental magnetic resonance imaging Part II: placenta accreta spectrum. Pediatr Radiol. 2020;50:275–284. doi: 10.1007/s00247-019-04521-2. [DOI] [PubMed] [Google Scholar]
- 25.Meyers ML, Brown BP. Placental magnetic resonance imaging Part I: the normal placenta. Pediatr Radiol. 2020;50:264–274. doi: 10.1007/s00247-019-04520-3. [DOI] [PubMed] [Google Scholar]
- 26.Mulligan KM, Bartels HC, Armstrong F, et al. Comparing three-dimensional models of placenta accreta spectrum with surgical findings. Int J Gynaecol Obstet. 2022;157:188–197. doi: 10.1002/ijgo.13743. [DOI] [PubMed] [Google Scholar]
- 27.Yip SS, Aerts HJ. Applications and limitations of radiomics. Phys Med Biol. 2016;61:R150–166. doi: 10.1088/0031-9155/61/13/r150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Zhovannik I, Bussink J, Traverso A, et al. Learning from scanners: Bias reduction and feature correction in radiomics. Clin Transl Radiat Oncol. 2019;19:33–38. doi: 10.1016/j.ctro.2019.07.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Hodges JL, Jr, ELL Estimates of location based on rank tests. Ann Math Statist. 1963;34(2):598–611. doi: 10.1214/aoms/1177704172. [DOI] [Google Scholar]
- 30.Benjamini Y, Hochberg Y. Controlling the false discovery rate: a practical and powerful approach to multiple testing. J Roy Stat Soc B. 1995;57:289–300. [Google Scholar]
- 31.Hastie T, Tibshirani R, Friedman JH, Friedman JH. The elements of statistical learning: data mining, inference, and prediction. New York: Springer; 2009. pp. 1–758. [Google Scholar]
- 32.IT. J . Principal component analysis. New York: Springer; 2002. [Google Scholar]
- 33.Team RC (2022) R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. URL https://www.R-project.org/.
- 34.(2022) KM. _caret: Classification and Regression Training_. R package version 6.0–93, <https://CRAN.R-project.org/package=caret>.
- 35.Xavier Robin NT, Hainard A, Tiberti N, Lisacek F, Sanchez J-C, Müller M. pROC: an open-source package for R and S+ to analyze and compare ROC curves. BMC Bioinformatics. 2011;12:77. doi: 10.1186/1471-2105-12-77. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.SimkoTWaV . R package 'corrplot'Visualization of a Correlation Matrix (Version 0.92) 2021. [Google Scholar]
- 37.Wu Q, Yao K, Liu Z, et al. Radiomics analysis of placenta on T2WI facilitates prediction of postpartum haemorrhage: a multicentre study. EBioMedicine. 2019;50:355–365. doi: 10.1016/j.ebiom.2019.11.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.McCall SJ, Deneux-Tharaux C, Sentilhes L, et al. Placenta accreta spectrum - variations in clinical practice and maternal morbidity between the UK and France: a population-based comparative study. BJOG. 2022;129:1676–1685. doi: 10.1111/1471-0528.17169. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Doctorvaladan SV, Jelks AT, Hsieh EW, Thurer RL, Zakowski MI, Lagrew DC. Accuracy of blood loss measurement during cesarean delivery. AJP reports. 2017;7:e93–e100. doi: 10.1055/s-0037-1601382. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Liu Y, Zhu W, Shen Y, Qiu J, Rao L, Li H. Assessing the accuracy of visual blood loss estimation in postpartum hemorrhage in Shanghai hospitals: a web-based survey for nurses and midwives. J Clin Nurs. 2021;30:3556–3562. doi: 10.1111/jocn.15860. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Shamshirsaz AA, Fox KA, Salmanian B, et al. Maternal morbidity in patients with morbidly adherent placenta treated with and without a standardized multidisciplinary approach. Am J Obstet Gynecol. 2015;212:218.e211–219. doi: 10.1016/j.ajog.2014.08.019. [DOI] [PubMed] [Google Scholar]
- 42.Jauniaux E, Jurkovic D, Hussein AM, Burton GJ. New insights into the etiopathology of placenta accreta spectrum. Am J Obstet Gynecol. 2022;227:384–391. doi: 10.1016/j.ajog.2022.02.038. [DOI] [PubMed] [Google Scholar]
- 43.Bourgioti C, Konstantinidou AE, Zafeiropoulou K, et al. Intraplacental fetal vessel diameter may help predict for placental invasiveness in pregnant women at high risk for placenta accreta spectrum disorders. Radiology. 2021;298:403–412. doi: 10.1148/radiol.2020200273. [DOI] [PubMed] [Google Scholar]
- 44.Moradmand H, Aghamiri SMR, Ghaderi R. Impact of image preprocessing methods on reproducibility of radiomic features in multimodal magnetic resonance imaging in glioblastoma. J Appl Clin Med Phys. 2020;21:179–190. doi: 10.1002/acm2.12795. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Chu C, Liu M, Zhang Y, et al. MRI-based radiomics analysis for intraoperative risk assessment in gravid patients at high risk with placenta accreta spectrum. Diagnostics (Basel) 2022;12(2):485. doi: 10.3390/diagnostics12020485. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Romeo V, Ricciardi C, Cuocolo R, et al. Machine learning analysis of MRI-derived texture features to predict placenta accreta spectrum in patients with placenta previa. Magn Reson Imaging. 2019;64:71–76. doi: 10.1016/j.mri.2019.05.017. [DOI] [PubMed] [Google Scholar]
- 47.Demircioğlu A. The effect of preprocessing filters on predictive performance in radiomics. Eur Radiol Exp. 2022;6:40. doi: 10.1186/s41747-022-00294-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Teng X, Zhang J, Zwanenburg A, et al. Building reliable radiomic models using image perturbation. Sci Rep. 2022;12:10035. doi: 10.1038/s41598-022-14178-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Zwanenburg A, Vallières M, Abdalah MA, et al. The image biomarker standardization initiative: standardized quantitative radiomics for high-throughput image-based phenotyping. Radiology. 2020;295:328–338. doi: 10.1148/radiol.2020191145. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Jauniaux E, Chantraine F, Silver RM, Langhoff-Roos J. FIGO consensus guidelines on placenta accreta spectrum disorders: epidemiology. Int J Gynaecol Obstet. 2018;140:265–273. doi: 10.1002/ijgo.12407. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The code used for the methods presented in this manuscript are provided as open source in a public repository. The image data used for analysis is not publicly available.