Abstract
Background
Studies evaluating the effectiveness and safety of telerehabilitation in patients undergoing total knee arthroplasty (TKA) have increased. However, the study quality and results differ, systematic reviews are limited. We aimed to synthesise systematic reviews and meta-analyses to assess the effects of telerehabilitation in patients post-TKA.
Materials and methods
Systematic reviews and meta-analyses regarding the effectiveness and safety of TKA telerehabilitation were retrieved from eight databases from establishment to 18 December 2022. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), A Measurement Tool to Assess Systematic Reviews 2 (AMSTAR 2), Risk of Bias in Systematic Reviews (ROBIS) and GRADE system were used to evaluate results, methods, bias and evidence quality.
Results
Thirteen systematic reviews and meta-analyses were analysed. The AMSTAR 2 showed low methodological quality in seven studies and very low quality in six. Among the key items, item 2 had been registered on website before systematic review in four reviews. Concerning item 4, did not provide a comprehensive search strategy in 4 reviews. For item 7, none of the reviews provided a list of reasons for excluding an article. For item 9, regarding whether appropriate tools were used to assess the risk of bias of each included study, one review was assessed as ‘partially yes’, one review only included RCTs, and the remainder were assessed as ‘yes’. For item 11, one review did not specify the statistical methods used, and three reviews did not conduct a meta-analysis. For item 13, four reviews considered the risk of bias when interpreting or discussing the study results. For item 15, seven reviews did not evaluate publication bias. The PRISMA scores of the 13 reviews ranged from 17.5 to 26.0. The PRISMA indicated that 69.2% had no protocol registration, 38.5% did not provide other materials and evidence certainty, 23.1% did not provide certainty assessment, 30.8% did not report study bias. According to the ROBIS scale, diferrent domains have diferrent risks in all the reviews.
Conclusion
Telerehabilitation positively affects walking ability, knee extension and patient costs post-TKA surgery. Regarding the quality of life, patient satisfaction and the WOMAC, telerehabilitation had similar effects to conventional rehabilitation. Owing to the low quality of the studies, these conclusions should be interpreted cautiously, high-quality studies are needed in the future.
Supplementary Information
The online version contains supplementary material available at 10.1186/s12938-023-01158-z.
Keywords: Total knee arthroplasty, Telerehabilitation, Knee replacement, Overview, Systematic review
Introduction
Total knee arthroplasty (TKA) is the gold standard treatment of end-stage knee osteoarthritis or in cases wherein conservative treatment is ineffective [1]. Knee osteoarthritis is a degenerative knee disease with a prevalence of 85% in individuals over 65 years [2]. The number of TKA surgeries has increased globally, with more than 1,000,000 performed annually in the United States [3]. Early post-operative rehabilitation is critical to relieving pain, enhancing muscle strength, preventing complications such as deep vein thrombosis, joint stiffness and wound infection [4], promoting joint function recovery and improving patients’ independent living ability and quality of life.
With the development of rapid rehabilitation, hospitalisation times for patients undergoing TKA have shortened [5], with rehabilitation performed at home and during regular outpatient follow-ups. However, owing to geographical restrictions, implementing standard guidelines and supervision by healthcare professionals may be limited, and patients who have undergone TKA may lack functional exercise-related knowledge. Complications such as pain and wound swelling may not resolve over time [6], and dependence on rehabilitation is low. Studies have shown that 10–30% of patients with TKA had no significant improvement in joint function and poor recovery of physical function, and reoperation could likely result in a high economic burden on individuals and society [7]. Therefore, the post-operative rehabilitation needs of patients undergoing TKA are increasing; with the development of information technology, conventional rehabilitation faces challenges. Telerehabilitation refers to remote medical treatment through communication and information technologies such as the internet, smartphones, virtual reality, video phones and wearable electronic devices, providing patients with timely rehabilitation guidance, remote supervision and no travel distance [8]. Compared with conventional rehabilitation, remote rehabilitation saves time and cost, enables patients to obtain more convenient home rehabilitation services, enhances enthusiasm for rehabilitation, helps ensure continuous nursing care and improves the quality of life [9–11].
Systematic reviews of the effects of telerehabilitation in patients undergoing TKA have gradually increased in recent years. However, the quality of the studies, reported results and conclusions appear to differ, making clinical decision making challenging. Re-evaluation of systematic reviews involves comparing, summarising and synthesising these systematic reviews and meta-analyses regarding the same or similar interventions, which could provide comprehensive and reliable evidence for clinical decision makers [12]. Therefore, this study aims to evaluate systematic reviews and meta-analyses of the effectiveness and safety of telerehabilitation in patients undergoing TKA regarding method, report and evidence quality and risk of bias to provide a reference for facilitating clinical decision making.
Results
Literature screening process and results
A total of 1019 studies were preliminarily retrieved, of which 853 remained after removing duplicates using EndNote X9. A total of 821 studies were excluded after reading the titles and abstracts; 32 were read in full text, of which 19 were excluded, and 13 were finally included. The literature screening process is shown in, and the reasons for exclusion are shown in Additional file 2: Appendix Table 2.
Basic features of the included studies
Of the 13 systematic reviews, one was published in Chinese and 12 were published in English between 2017 and 2022. The number of original studies ranged from 4 to 28, and the sample size ranged between 230 and 6418 participants. All systematic reviews included randomised controlled trials (RCTs); some included prospective, observational and case–control studies. The Cochrane bias risk assessment tool was used in five studies, the Physiotherapy Evidence Database (PEDro) scale was used in four, the Joanna Briggs Institute RCT assessment tool was used in two, the Jadad scale was used in one, and the quality assessment tool was not specified in one. The intervention groups underwent remote rehabilitation, including videoconferencing and virtual reality rehabilitation, whereas the control groups underwent conventional rehabilitation and routine nursing (Table 1).
Table 1.
First author | Year | Country | Number of original studies (sample size) | Research type | Intervening measure | Comparison intervention | Outcome | Quality evaluation tool |
---|---|---|---|---|---|---|---|---|
McKeon, et al. [18] | 2021 | America | 28 (6418) | RCT | Tele-rehabilitation | Face-to-face rehabilitation | WOMAC, KOOS, TUGT, satisfaction,cost | Not specified |
McDonnell, et al. [19] | 2022 | Ireland | 11 (1054) | RCT | Video-conferencing | Face-to-face rehabilitation | Satisfaction,VAS, WOMAC,TUGT | Cochrane bias risk assessment tool |
Jansson, et al. [20] | 2022 | Finland | 9 (1266) | RCT | Tele-rehabilitation | Face-to-face outpatient treatment | Joint flexion and extension, TUGT, VAS, life quality,WOMAC, KOOS | JBI randomized controlled trial evaluation tool |
Jiang, et al. [26] | 2018 | China | 4 (422) | RCT | Tele-rehabilitation | Face-to-face rehabilitation | VAS, WOMAC, active buckling and extension | Jadad scale |
Gazendam, et al. [27] | 2022 | Canada | 9 (835) | RCT | Virtual reality rehabilitation | Face-to-face rehabilitation | VAS, WOMAC, KOOS, cost | Cochrane risk assessment tool |
Wang, et al. [30] | 2021 | Australia | 11 (1020) | RCT | Internet rehabilitation | Face-to-face outpatient rehabilitation, home visits or routine care | Pain, knee flexion and extension, quality of life, satisfaction | JBI randomized controlled trial evaluation tool |
Jing, et al. [21] | 2019 | China | 6 (601) | RCT | Tele-rehabilitation | Routine outpatient physical therapy or home visit | WOMAC, joint flexion and extension, VAS, KOOS, TUGT | Cochrane Manual 5.1.0 |
Wang, et al. [23] | 2019 | Australia | 21 (2188) | RCT | Tele-rehabilitation | Routine care | VAS, TUGT, WOMAC, life quality | PEDro scale |
Tsang, et al. [24] | 2022 | China | 11 (1825) | RCT | Tele-rehabilitation | Standard rehabilitation therapy | VAS, WOMAC, KOOS, cost, adverse event | PEDro scale |
Peng, et al. [28] | 2021 | China | 8 (805) | RCT | Virtual reality rehabilitation | Standard rehabilitation therapy | VAS, WOMAC, TUGT, life quality | PEDro scale |
Blasco, et al. [29] | 2021 | Spain | 6 (312) | RCT, case–control study | Virtual reality rehabilitation | Standard rehabilitation therapy | Pain, patient satisfaction | PEDro scale |
Shukla, et al. [25] | 2017 | India | 6 (408) | RCT, observational study | Tele-rehabilitation | Conventional rehabilitation | Active knee flexion and extension, VAS, life quality | Cochrane bias risk tool |
Yoo, et al. [22] | 2022 | Korea | 9 (230) | RCT, prospective study | Robot-assisted rehabilitation | Usual care | VAS | Cochrane bias risk tool, NOS scale |
JBI Joanna Briggs Institute model of evidence-based healthcare, KOOS knee injury and osteoarthritis outcome score, RCT randomized controlled trial, TKA total knee arthroplasty, TUGT timed up and go test, VAS pain visual analogue score, WOMAC Western Ontario and McMaster Universities osteoarthritis index
Results of methodological quality evaluation
Among the 13 systematic reviews included, seven [20, 22, 26–30] had low methodological quality, and six [18, 19, 21, 23–25] had very low methodological quality. Among the key items, item 2 in four reviews [22, 23, 28, 29] had been registered on a website before commencing the systematic review. Concerning item 4, four reviews [18, 19, 21, 26] did not provide a comprehensive search strategy. For item 7, none of the reviews [18–30] provided a list of reasons for excluding an article. For item 9, regarding whether appropriate tools were used to assess the risk of bias of each included study, one review [18] was assessed as ‘partially yes’, one review [25] only included RCTs, and the remainder were assessed as ‘yes’. For item 11, one review [25] did not specify the statistical methods used, and three reviews [18, 20, 29] did not conduct a meta-analysis. For item 13, four reviews [19, 22, 26, 28] considered the risk of bias when interpreting or discussing the study results. For item 15, seven reviews [19, 22–24, 26, 28, 30] did not evaluate publication bias. Among the noncritical weaknesses and in relation to item 10, none of the reviews [18–30] described the funding source (Table 2).
Table 2.
Review | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | Grade |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
McKeon, et al. [18] | Y | N | Y | N | Y | Y | P | Y | P | N | NM | NM | N | Y | NM | Y | CL |
McDonnell, et al. [19] | Y | N | Y | P | Y | Y | P | P | Y | N | Y | Y | Y | Y | N | Y | CL |
Jansson et al. [20] | Y | P | Y | Y | Y | Y | P | Y | Y | N | NM | NM | N | N | NM | Y | Low |
Liu, et al. [21] | Y | N | Y | P | Y | Y | P | Y | Y | N | Y | N | N | Y | Y | Y | CL |
Yoo, et al. [22] | Y | Y | Y | Y | Y | Y | P | Y | Y | N | Y | Y | Y | N | N | Y | Low |
Wang, et al. [23] | Y | Y | Y | Y | Y | Y | P | Y | Y | N | Y | Y | N | Y | N | Y | CL |
Tsang, et al. [24] | Y | P | Y | Y | Y | Y | P | Y | Y | N | Y | N | N | Y | N | Y | CL |
Shukla, et al. [25] | N | N | Y | Y | N | Y | P | P | RCT | N | N | Y | N | Y | Y | Y | CL |
Jiang, et al. [26] | Y | P | Y | P | N | N | P | Y | Y | N | Y | N | Y | Y | N | Y | Low |
Gazendam, et al. [27] | Y | P | Y | Y | Y | Y | P | P | Y | N | Y | Y | N | N | Y | Y | Low |
Peng, et al. [28] | Y | Y | Y | Y | Y | Y | P | Y | Y | N | Y | N | Y | Y | N | Y | Low |
Blasco, et al. [29] | Y | Y | N | Y | N | Y | P | P | Y | N | NM | NM | N | N | NM | Y | Low |
Wang, et al. [30] | Y | P | Y | P | Y | Y | P | Y | Y | N | Y | Y | Y | Y | N | Y | Low |
N no, Y yes, P partly yes, NM no meta-analysis, RCT randomized controlled trial, CL Critically low
Literature report quality evaluation results
The PRISMA scores of the 13 systematic reviews ranged from 17.5 to 26.0. No systematic review reported serious defects, three reported some defects [18, 26, 30], and 10 reports were relatively complete [19–25, 27–29]. The title, abstract, introduction, source of information, study selection, study characteristics, study risk of bias and discussion have been fully reported in all reviews [18–30]. Nine reviews [18–21, 24–27, 30] did not register protocols; five [18–21, 26] did not provide the availability of data, code and other materials; three [18, 24, 30] did not provide certainty assessment, five [18, 22, 28–30] did not report the certainty of evidence; and four [18, 20, 24, 28] did not report study bias (Table 3).
Table 3.
Section/topic | Items | McKeon, et al. [18] | McDonnell, et al. [19] | Jansson, et al. [20] | Liu, et al. [21] | Yoo, et al. [22] | Wang, et al. [23] | Tsang, et al. [24] | Shukla, et al. [25] | Jiang, et al.[26] | Gazendam, et al. [27] | Peng, et al. [28] | Blasco, et al. [29] | Wang, et al. [30] | Total points |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Title | T1 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 |
Abstract | T2 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 |
Introduction | T3 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 |
T4 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 | |
Method | T5 | Y | Y | Y | Y | Y | P | Y | P | P | Y | Y | Y | Y | 11.5 |
T6 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 | |
T7 | P | P | Y | P | Y | Y | Y | Y | P | Y | Y | Y | P | 10.5 | |
T8 | N | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | P | Y | 10.5 | |
T9 | Y | Y | Y | Y | Y | Y | Y | P | P | Y | Y | Y | P | 11.5 | |
T10 | Y | Y | Y | Y | Y | Y | Y | P | Y | Y | Y | P | Y | 12.0 | |
T11 | Y | Y | Y | P | Y | Y | Y | Y | P | P | Y | Y | Y | 11.5 | |
T12 | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 12.0 | |
T13 | N | Y | P | Y | P | Y | Y | N | Y | Y | Y | Y | P | 9.5 | |
T14 | N | Y | N | Y | P | Y | N | Y | Y | P | N | P | P | 7.0 | |
T15 | N | P | P | P | P | P | N | P | P | P | P | P | N | 5.0 | |
Result | T16 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 |
T17 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 | |
T18 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | 13.0 | |
T19 | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | P | 11.5 | |
T20 | P | Y | Y | Y | Y | Y | P | Y | Y | P | Y | Y | P | 11.0 | |
T21 | P | Y | N | Y | Y | Y | N | Y | N | Y | Y | Y | Y | 9.5 | |
T22 | N | P | P | P | N | Y | P | P | P | Y | N | N | N | 5.0 |
N no, P partly yes, Y yes, T1 title, T2 abstract, T3 Rationale, T4 objectives, T5 Eligibility criteria, T6 information sources, T7 search strategy, T8 Selection process, T9 Data collection process, T10 data items; T11 Study risk of bias assessment, T12 Effect measures; T13 Synthesis methods, T14 Reporting bias assessment, T15 Certainty assessment, T16 study selection, T17 study characteristics, T18 risk of bias in studies, T19 results of individual studies, T20 Results of syntheses, T21 Reporting biases, T22 Certainty of evidence, T23 discussion, T24 registration and protocol, T25 support, T26 Competing interests, T27 Availability of data, code and other materials
Biased risk assessment results
According to the ROBIS scale domain 1, the inclusion criteria, all the reviews (100%) were low risk. Regarding domain 2, research identification and selection, all reviews (100%) were high risk. In terms of domain 3, data extraction and quality assessment, two reviews (15.4%) were high risk. Regarding domain 4, data synthesis and results presentation, 10 reviews (76.9%) were high risk; in stage 3, all reviews (100%) had a high risk of bias, as shown in Table 4.
Table 4.
Review | Phase 2 | Phase 3 | |||
---|---|---|---|---|---|
Research inclusion criteria | Research identification and selection | Data extraction and quality evaluation | Data synthesis and results presentation | Risk of bias | |
McKeon, et al. [18] | √ | × | × | ? | × |
McDonnell, et al. [19] | √ | × | √ | × | × |
Jansson, et al. [20] | √ | × | √ | × | × |
Liu, et al. [21] | √ | × | ? | × | × |
Yoo, et al. [22] | √ | × | √ | ? | × |
Wang, et al. [23] | √ | × | √ | × | × |
Tsang, et al. [24] | √ | × | √ | × | × |
Shukla, et al. [25] | √ | × | ? | × | × |
Jiang, et al. [26] | √ | × | × | √ | × |
Gazendam, et al. [27] | √ | × | √ | × | × |
Peng, et al. [28] | √ | × | √ | × | × |
Blasco, et al. [29] | √ | × | √ | × | × |
Wang, et al. [30] | √ | × | √ | × | × |
√, low risk; × , high risk; ?, not sure
Evidence quality evaluation results
The evidence quality evaluation results showed that among the 59 outcome indicators in the 13 reviews, there was no high-quality evidence, and there were 14 medium-quality and 33 low-quality indicators. The main reason for downgrade was the limitations of the original study, followed by publication bias and inconsistency, as shown in Table 5.
Table 5.
Review | Outcomes | Studies (participants) | Heterogeneity | Relative effect (95% CI) | P value | Grade level |
---|---|---|---|---|---|---|
McKeon, et al. [18] | WOMAC | 12 (1325) | NR | NR | NR | Low |
KOOS | 12 (363) | NR | NR | P < 0.001 | Low | |
TUGT | 5 (499) | NR | NR | P = 0.30 | Low | |
Patient satisfaction | 7 (1832) | NR | NR | NR | Low | |
Cost | 4 (1275) | NR | NR | NR | Low | |
Pain | 3 (281) | NR | NR | P > 0.05 | Low | |
McDonnell et al. [19] | Patient satisfaction | 4 (287) | 0% | RR = 0.98(0.90–1.07) | P = 0.52 | Moderate |
Pain | 4 (294) | 25% | SMD = − 0.33(− 0.61, − 0.65) | P = 0.02 | Moderate | |
WOMAC | 3 (294) | 0% | SMD = 0.12(− 0.11, 0.35) | P = 0.30 | Low | |
TUGT | 6 (397) | 73% | SMD = 0.19(− 0.25, 0.63) | P = 0.40 | CL | |
Jansson, et al. [20] | Joint flexion | 3 (255) | NR | NR | P > 0.05 | low |
Joint extension | 4 (315) | NR | SMD = − 0.06 (− 0.55–0.43) | P > 0.05 | Low | |
TUGT | 3 (267) | NR | NR | NR | Low | |
WOMAC | 3 (449) | NR | NR | P < 0.05 | Low | |
KOOS | 3 (427) | NR | NR | P > 0.05 | Low | |
Pain | 5 (477) | NR | NR | P > 0.05 | Low | |
Life quality | 1 (400) | NR | NR | P < 0.05 | Low | |
Adverse event | 1 (225) | NR | NR | P < 0.05 | Low | |
Cost | 4 (467) | NR | MD = − 263 (382–143) | P < 0.001 | Low | |
Liu, et al. [21] | WOMAC | 4 (532) | 90% | MD = − 0.32(− 2.30 ~ 1.65) | P = 0.75 | CL |
Joint flexion | 4 (532) | 86% | MD = 0.68 (− 2.28 ~ 3.63) | P = 0.65 | CL | |
Pain | 3 (236) | 0% | MD = − 0.43 (− 0.85 ~ − 0.01) | P = 0.04 | Moderate | |
KOOS | 2 (234) | 0% | MD = − 1.10 (− 1.63 ~ − 0.57) | P < 0.001 | CL | |
TUGT | 3 (248) | 84% | MD = − 5.17 (− 9.79 ~ − 0.55) | P = 0.03 | Low | |
Liu, et al. [21] | Joint extension | 3 (512) | 0% | MD = 0.30 (0.20 ~ 0.40) | P < 0.001 | Moderate |
Yoo, et al. [22] | Pain | 2 (42) | 5% | SMD = 1.05 (0.39–1.71) | P = 0.30 | Low |
Wang, et al. [23] | Pain | 3 (409) | 0% | MD = − 0.19(− 0.36, − 0.03) | P = 0.02 | Moderate |
TUGT | 2 (207) | 60% | MD = − 073(-11.18,-2.88) | P = 0.0009 | CL | |
WOMAC | 4 (746) | 15% | MD: − 0.09 (− 0.22, 0.04) | P = 0.18 | Low | |
Life quality | 6 (681) | NR | NR | P = 0.05 | Low | |
Tsang, et al. [24] | Joint extension | 4 (699) | 0% | SMD = − 0.19 (− 0.34 ~ − 0.04) | P = 0.01 | Low |
Joint flexion | 5 (886) | 45% | SMD = 0.12(− 0.07–0.30) | P = 0.12 | Low | |
Pain | 7 (787) | 74% | SMD = -0.15(− 0.47–0.16 | P = 0.34 | CL | |
WOMAC | 8 (1219) | 83% | SMD = 0.23(− 0.44 ~ 0.91) | P = 0.50 | CL | |
Cost | 2 (316) | NR | NR | p < 0.001 | Low | |
KOOS | 4 (804) | NR | NR | NR | Low | |
Adverse event | 4 (1165) | NR | NR | P = 0.007 | Low | |
Shukla, et al. [25] | Joint extension | 3 (248) | 0% | MD = − 0.52 (− 1.39, 0.35) | P = 0.24 | Low |
Joint flexion | 3 (248) | 0% | MD = − 0.52 (− 1.39, 0.35) | P = 0.24 | CL | |
Pain | 2 (302) | 0% | MD = − 0.02 (− 0.46–0.41) | P = 0.91 | CL | |
Life quality | 1 (160) | NR | MD = 0.39 (0.46–7.34) | P = 0.03 | CL | |
Jiang, et al. [26] | Pain | 2 (161) | 0% | MD = 0.52 (− 0.20–1.24) | P = 0.16 | Low |
WOMAC | 2 (207) | 0% | MD = 1.13 (0.23–2.02) | P = 0.014 | Low | |
Joint flexion | 2 (198) | 0% | MD = 2.40 (− 0.34–5.15) | P = 0.09 | Low | |
Joint extension | 3 (396) | 0% | MD = 0.30 (0.20–0.40) | P < 0.00001 | Moderate | |
Gazendam, et al. [27] | Pain | 3 (282) | 84% | MD = − 3.30 (− 8.03,1.43) | P = 0.17 | CL |
WOMAC KOOS | 4 (457) | 73% | MD = − 3.32 (− 5.20 ~ − 1.45) | P = 0.08 | Low | |
Cost | 1 (306) | NR | NR | p < 0.001 | CL | |
Peng L, et al. [28] | Pain | 3 (360) | 91% | SMD = − 0.44 (− 0.79 ~ − 0.08) | P = 0.02 | Moderate |
WOMAC | 4 (257) | 0% | SMD = − 0.71 (− 1.03 ~ − 0.40) | p < 0.01 | Moderate | |
TUGT | 2 (163) | 77.9% | SMD = − 0.34 (− 1.31–0.63) | P = 0.03 | Low | |
Life quality | 2 (161) | NR | NR | NR | Low | |
Blasco J, et al. [29] | Pain | 2 (192) | NR | NR | NR | Moderate |
Patient satisfaction | 3 (107) | NR | NR | NR | Low | |
Wang, et al. [30] | Pain | 6 (794) | 48% | SMD = − 0.11(− 0.32–0.10) | P = 0.30 | Moderate |
Joint flexion | 4 (446) | 0% | MD = 0.65(− 1.18, 2.48) | P = 0.48 | Moderate | |
Joint extension | 4 (446) | 0% | MD = − 0.38(-1.16, 0.40) | P = 0.34 | Moderate | |
Life quality | 5 (652) | 7% | SMD = − 0.09(− 0.26, 0.07) | P = 0.26 | Moderate | |
Patient satisfaction | 3 (512) | 0% | SMD = 0.04(− 0.21–0.14) | P = 0.67 | Moderate |
SMD standardized mean difference, MD mean difference, RR relative risk, NR not report, CL Critical low
JBI Joanna Briggs Institute model of evidence-based healthcare, KOOS knee injury and osteoarthritis outcome score, RCT randomized controlled trial, TKA total knee arthroplasty, TUGT timed up and go test, VAS pain visual analogue score, WOMAC Western Ontario and McMaster Universities osteoarthritis index
Evaluation results of main outcome indicators
Pain
Thirteen reviews [18–30] evaluated pain. Two reviews [19, 21] showed statistically significant pain improvement in telerehabilitation groups compared with control groups, whereas 10 reviews [18, 20, 22–27, 29, 30] showed that telerehabilitation had no statistically significant effect on pain in patients who underwent TKA. Subgroup analysis in one review [28] showed that virtual reality rehabilitation could improve pain within 1 month after TKA surgery (SMD = − 0.44, 95% CI − 0.79–0.08, P = 0.02) but did not improve pain 2–3 months after surgery (SMD = − 0.35; 95% CI − 1.02–0.32, P = 0.31).
Knee function
Regarding the WOMAC indices, nine reviews [18–21, 23, 24, 26–28] evaluated the effect of telerehabilitation on WOMAC scores, six reviews [18–21, 23, 24] showed that the effects of telerehabilitation in terms of WOMAC scores were similar to those for standard care and three reviews [26–28] showed statistically significant effects of telerehabilitation in terms of WOMAC scores.
In terms of KOOS, five reviews [18, 20, 21, 24, 27] reported the effects of telerehabilitation on KOOS. Three reviews [18, 21, 27] showed that the telerehabilitation groups had improved KOOS compared with the control groups. In contrast, two other reviews [20, 24] showed no significant difference in KOOS between the telerehabilitation and control groups.
Regarding knee flexion and extension, six reviews [20, 21, 24–26, 30] evaluated knee flexion and extension and joint flexion, and the results showed that the effect of telerehabilitation on knee flexion was not statistically significant. In terms of joint extension, four reviews [21, 24–26] showed that telerehabilitation had a statistically significantly improved joint extension (P < 0.01), and two reviews [20, 30] showed that there was no statistically significant difference in joint extension between the two groups.
In terms of walking ability, six reviews [18–21, 23, 28] used the TUG test to evaluate the effect of telerehabilitation on walking ability. Three reviews [18, 21, 23] showed that telerehabilitation shortened the TUG test compared with standard rehabilitation, and two reviews [19, 28] showed no significant difference in TUG scores between the two groups. One review [20] conducted a descriptive analysis and reached no conclusions.
In terms of quality of life, three reviews [20, 28, 30] evaluated the effect of telerehabilitation on quality of life, and a meta-analysis of one medium-quality review [30] showed no significant difference in terms of changes in quality of life between the intervention and control groups.
Evaluation results of secondary outcome indicators
Adverse events
Two reviews [20, 24] reported the influence of telerehabilitation on adverse events. Jansson et al. [20] showed that telerehabilitation had no significant effect on the occurrence of adverse events. Tsang et al. [24] reported that the rehospitalisation rate in an intervention group within 12 weeks was significantly lower than in a control group. However, the evidence quality was low.
Patient satisfaction
Four reviews [18, 19, 29, 30] evaluated the intervention effect of telerehabilitation on patient satisfaction. One review [18] showed that the telerehabilitation and control groups had similar patient satisfaction levels. Three reviews [19, 29, 30] showed that the changes in patient satisfaction were not statistically significant in either group.
Cost
Four reviews [18, 20, 24, 27] evaluated the effects of telerehabilitation on costs, and the results showed that telerehabilitation could reduce patient medical costs compared with expenses incurred in the control groups.
Discussion
Telerehabilitation can provide patients with more flexible and convenient rehabilitation services using information technology, which compensates for shortcomings of conventional rehabilitation and is a complementary or alternative method to conventional nursing [9]. In this study, the AMSTAR-2, PRISMA, GRADE and ROBIS grades were used for the first time to review the effectiveness and safety of telerehabilitation in patients following TKA to provide more evidence for clinical decision making. Among the 13 systematic reviews and meta-analyses, 92.3% were published in the last 5 years, indicating increasing attention to telerehabilitation in recent years.
Based on the evaluation results of AMSTAR 2, the quality of the methodologies included in these reviews should be improved. The main issues identified in terms of critical weaknesses included item 2 (scheme registration in advance), item 4 (the comprehensive retrieval strategy) (n = 4, 30.8%), item 7 (the list of reasons for the exclusion of each document not being provided) (n = 13, 100%), item 13 (the risk of inclusion bias not considered when interpreting or discussing the findings) (n = 8, 61.5%) and item 15 (publication bias not being evaluated and discussed) (n = 7, 53.8%). Among the noncritical weaknesses, none of the systematic reviews described the source of funding for the included original research, and the study results may have been affected by the funding situation. Future systematic reviews and meta-analyses should strictly comply with the AMSTAR 2 standards to reduce methodological defects and bias and improve rigour.
According to the PRISMA 2020 assessment results, most reviews (76.9%) were relatively complete; however, none fully matched the quality of the PRISMA reports. The main issues were as follows: nine reviews (69.2%) did not have study protocol registration numbers, five (38.5%) did not provide other available materials and evidence certainty, four (30.8%) did not report study bias, and three (23.0%) did not perform certainty assessment. Future systematic reviews should follow the PRISMA report list to avoid these problems.
According to the ROBIS bias risk assessment results, domains 2 and 4 in the second stage had a high risk of bias. The main issues in determining and selecting research in domain 2 were as follows: most of the reviews were retrieved from the MEDLINE and Embase databases. However, conference reports and clinical trial registration platforms were not retrieved, and some reviews had restrictions on publication form and language, leading to bias. Shortcomings regarding data synthesis and result presentation in domain 4 included the inability to assess adherence to the predetermined scheme, the absence of sensitivity analysis and the potential unreliability of some results. In the third stage, all the reviews showed a high risk of bias, which may be related to the lack of a corresponding explanation and treatment of the partial bias risk in the second stage.
According to the GRADE evidence quality evaluation results, most of the 59 outcome indicators (55.9%) had low-quality or no high-quality evidence. The main factors affecting the evidence quality were the limitations of the original studies in terms of randomisation, blinding methods and allocation hiding. The second factor was publication bias, owing to the limited number of included studies or small sample sizes, lack of funnel plot analysis and other relevant considerations. In addition, due to the different intervention methods and measurement tools used in the included studies, heterogeneity was high, which affected the quality of evidence. A detailed description of the inclusion and exclusion criteria and appropriate subgroup analyses were required. In conclusion, clinical studies should focus on improving quality and standardising research methods to provide more reliable and objective data.
Our findings indicate that telerehabilitation positively affected walking ability, knee extension and costs for patients after TKA. Telerehabilitation was similar to conventional rehabilitation regarding the WOMAC score, quality of life and patient satisfaction. Telerehabilitation had no significant effect on pain or joint flexion. In addition, the effect of telerehabilitation on KOOS and adverse events in patients with TKA remains controversial. However, the above results should be treated with caution owing to the low quality of the studies assessed in systematic reviews and meta-analyses.
Recommendations for future studies
Systematic reviews should follow the AMSTAR 2, PRISMA and ROBIS guidelines; protocol registration should be conducted before study initiation; research transparency should be enhanced; search strategies and databases should be comprehensive; a list should be provided when excluding the literature and reasons given; and the source of funding for the original study should be clarified. This study also found that the evidence quality of some original studies was not high. Therefore, sample sizes should be increased in future studies to reduce bias in randomisation, blinding methods and allocation hiding. Moreover, because telerehabilitation includes multiple types, a subgroup analysis should be performed when there is significant heterogeneity among the different types. Finally, the existing literature has not paid sufficient attention to patients’ adverse reactions or safety indicators after telerehabilitation. Future studies should also consider these indicators.
This study had some limitations. Owing to language limitations, this study only conducted searches in an English language databases; studies published in other languages may have been missed. There may have been duplications in the original studies included in the systematic reviews, which were not evaluated in this study. Telerehabilitation involves various intervention methods, and there was considerable heterogeneity among the different interventions. Only the descriptive analysis was used in this study, and no combined effect values were used for the quantitative analysis. Finally, although the AMSTAR-2, PRISMA 2020, ROBIS and GRADE systems were used for evaluation according to the appropriate standards, the evaluation process and results might remain subjective.
Conclusion
In this study, telerehabilitation positively affected walking ability, knee extension and costs in patients who underwent TKA. Regarding patients’ quality of life, WOMAC scores and patient satisfaction, telerehabilitation had effects similar to conventional rehabilitation. However, these reported outcomes were influenced by the methodology, reporting quality, risk of bias and quality of evidence in the original studies. Therefore, the conclusions should be interpreted with caution. High-quality RCTs and systematic reviews are required to provide reliable evidence.
Materials and methods
This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) list [13] and was registered in the International Prospective Register of Systematic Reviews (PROSPERO) (registration number: CRD42023401152). The inclusion criteria were male or female patients aged ≥ 18 who underwent TKA.
The intervention groups comprised those who had undergone remote rehabilitation using the internet, smartphones, virtual reality or conference calls. The control groups received routine nursing and face-to-face rehabilitation therapy or were the blank control group. The primary outcome measures were pain, knee flexion and extension, timed up and go (TUG) test score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, knee injury and osteoarthritis outcome score (KOOS) and patient quality of life. The secondary outcome measures were adverse events, patient satisfaction and costs. The study type comprised systematic reviews of telerehabilitation in patients who underwent TKA with or without meta-analyses. The exclusion criteria comprised studies not published in English or Chinese, duplicate publications, conference abstracts, studies where the full text is unobtainable, studies mainly measuring the performance of applications and wearable devices and studies involving patients with other comorbidities in which TKA was not the main research topic.
Retrieval databases
We searched PubMed, Cochrane Library, Embase, Cumulated Index to Nursing and Allied Health Literature, Web of Science, China National Knowledge Infrastructure and Veip databases from their establishment to 18 December 2022. A preliminary search was conducted to expand the search terms, and a combination of subject headings and free words was then used to search multiple databases. Finally, the PROSPERO website and references included in the literature were searched manually. The following search terms were used: knee replacement OR joint replacement, telemedicine OR remote rehabilitation OR internet OR video conference, video phone, virtual reality, WeChat, smartphone, application, wearable device, digital health, artificial intelligence, phone OR SMS and meta-analysis, systematic review, meta-analysis OR meta-analysis (see Additional file 1: Appendix Table 1 for specific search strategies).
Literature screening and data extraction
Literature screening
After all the retrieved results were imported into EndNote X9 for duplication removal, two researchers independently screened the literature, first reading the title and abstract, excluding inconsistent literature, and then reading the full text to determine the suitability of the study for inclusion. The two researchers crosschecked and discussed any disagreements with a third person.
Data extraction
Two researchers separately extracted data from the literature that met the research criteria according to a preformulated Excel extraction table. The extracted data included the first author, year, country, number of original studies/sample size, study type, study subjects, intervention measures, control measures, outcome indicators, quality assessment tools and meta-analyses. In cases of disagreement, discussions were held with a third party.
Evaluation of literature quality
Evaluation of methodological quality
Two authors used the A Measurement Tool to Assess Systematic Reviews 2 (AMSTAR 2) [14] scale to evaluate the methodological quality of the included studies (16 items in total). Each item was indicated by ‘yes’, ‘no’ and ‘partly yes’, and the key items were 2, 4, 7, 9, 11, 13 and 15. The final quality was divided into four grades as follows: (i) high quality, none or only one noncritical weakness; (ii) medium quality, more than one noncritical weakness; (iii) low quality, one critical flaw with or without noncritical weaknesses; and (iv) very low quality, more than one critical flaw with or without noncritical weaknesses. The results were checked after the evaluation, and any disagreement was resolved through discussion with a third person(fei wang).
Reporting quality evaluation
Two researchers evaluated each study’s quality using PRISMA [13], the preferred reporting method for determining items when assessing systematic reviews and meta-analyses. There were 27 items, including the title, abstract, introduction, methods, results, discussion and funding statements. The presence, partial presence or absence of each item was indicated by ‘yes’, ‘partially yes’ and ‘no’, with scores of 1, 0.5 and 0, respectively, with a total possible score of 27. A score of ≤ 15 was defined as a relatively severe information deficiency, 15–21 showed a certain reporting deficiency, and 21–27 indicated that the report was relatively complete. The results were checked after the evaluation, and discussions were held with a third person (fei wang)when the researchers disagreed.
Risk of bias assessment
The risk of bias was assessed by two researchers using the Risk of Bias in Systematic Reviews (ROBIS) scale [15], which consists of three stages. The first stage assessed the correlations (selected based on the situation). The second stage determined the risk of bias in the process of systematic review production in terms of four areas: the inclusion criteria, search and screening, data extraction and quality assessment and data synthesis and presentation of results, with a total of 21 items. The third stage determined the ROBIS as high risk, low risk or uncertain. Using ROBIS, we checked the results following this evaluation, and any disagreements were discussed with a third person(fei wang).
Grading of evidence quality
Two researchers used the standard Grading of Recommendations Assessment, Development and Evaluation (GRADE) system [16] to evaluate the risks of bias, imprecision, inconsistency, indirectness and publication bias. The evidence quality was divided into four grades: high, medium, low and very low [17]. After the evaluation, the results were checked, and any differences were discussed with a third person(fei wang).
Data analysis methods
Descriptive methods were used because of the high heterogeneity of the included studies in terms of intervention methods and outcome indicators.
Supplementary Information
Acknowledgements
Not applicable.
Author contributions
DP designed and conceived the study; DP, AS, and FW undertook the literature screening and data extraction, and evaluated study quality; JL evaluated the data; DW and YG participated in the revising the manuscript and in providing guidance.
Funding
This study was funded by the New Entry Master Training Project (project number: YKDEY2022013) and University-level project of Ningxia Medical University.
Availability of data and materials
All data generated or analysed during this study are included in this article. Further enquiries can be directed to the corresponding author.
Declarations
Ethics approval and consent to participate
An ethics statement is not applicable because this study is based exclusively on published literature.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) list and was registered in the International Prospective Register of Systematic Reviews (PROSPERO) (Registration Number: CRD42023401152).
Consent for publication
Not applicable.
Competing interests
The authors declare to have no potential competing interests in relation to this study.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Kolasinski SL, Neogi T, Hochberg MC, et al. 2019 American college of rheumatology/arthritis foundation guideline for the management of osteoarthritis of the hand, hip, and knee. Arthritis Care Res. 2020;72(2):149–162. doi: 10.1002/acr.24131. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Joint Surgery Group of Orthopaedic Branch of Chinese Medical Association, Osteoarthritis Group of Orthopaedic Branch of Chinese Medical Doctor Association, Xiangya Hospital of National Clinical Medical Research Center for Geriatric Diseases, et al. Chinese guideline for diagnosis and treatment of osteoarthritis (2021 edition). Chinese Journal of Orthopedics. 2021;41(18):1291–1314. 10.3760/cma.j.cn121113-20210624-00424.
- 3.Heath EL, Ackerman IN, Cashman K, et al. Patient-reported outcomes after hip and knee arthroplasty: results from a large national registry. Bone Jt Open. 2021;2(6):422–432. doi: 10.1302/2633-1462.26.BJO-2021-0053.R1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Liu J, Li LL, Gan YY. Application of tele-rehabilitation in patients undergoing total knee replacement. J Anhui Med. 2022;43(12):1479–1482. [Google Scholar]
- 5.Pan YW, Qin DC, Chen XL, et al. A short-term study of integrated enhanced recovery after surgery in total knee arthroplasty. Orthop J China. 2022;30(24):2297–2299. [Google Scholar]
- 6.Qu QQ, Yang YT, Zhang Z. Research progress on intervention strategies for functional exercise compliance of patients after artificial joint replacement. Nurs Res. 2022;36(12):2221–2224. doi: 10.12102/j.issn.1009-6493.2022.12.030. [DOI] [Google Scholar]
- 7.Olsen U, Lindberg MF, Rose C, et al. Factors correlated with physical function 1 year after total knee arthroplasty in patients with knee osteoarthritis: a systematic review and meta-analysis. JAMA Netw Open. 2022;5(7):e2219636. doi: 10.1001/jamanetworkopen.2022.19636. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Zhu JF, Zhang YX, Wang F, et al. The effectiveness and safety of telerehabilitation management in stroke patients:an overview of systematic reviews. Chin J Nurs. 2022;57(12):1447–1455. doi: 10.3761/j.issn.0254-1769.2022.12.006. [DOI] [Google Scholar]
- 9.Wang Q, Lee RLT, Hunter S, et al. The effectiveness of internet-based telerehabilitation among patients after total joint arthroplasty: an integrative review. Int J Nurs Stud. 2021;115:103845. doi: 10.1016/j.ijnurstu.2020.103845. [DOI] [PubMed] [Google Scholar]
- 10.Knepley KD, Mao JZ, Wieczorek P, et al. Impact of telerehabilitation for stroke-related deficits. Telemed J E Health. 2021;27(3):239–246. doi: 10.1089/tmj.2020.0019. [DOI] [PubMed] [Google Scholar]
- 11.Velayati F, Ayatollahi H, Hemmat M. A systematic review of the effectiveness of telerehabilitation interventions for therapeutic purposes in the elderly. Methods Inf Med. 2020;59(2–03):104–109. doi: 10.1055/s-0040-1713398. [DOI] [PubMed] [Google Scholar]
- 12.Zheng J, Zhang Z, Han R, et al. Effects of exercise-based home pulmonary rehabilitation on patients with chronic obstructive pulmonary disease: an overview of systematic review. PLoS ONE. 2022;17(11):e0277632. doi: 10.1371/journal.pone.0277632. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. PLoS Med. 2021;18(3):e1003583. doi: 10.1371/journal.pmed.1003583. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Hu Y. Evidence-based nursing. Beijing: People’s Medical Publishing House; 2012. [Google Scholar]
- 15.Whiting P, Savović J, Higgins JP, et al. ROBIS: a new tool to assess risk of bias in systematic reviews was developed. J Clin Epidemiol. 2016;69:225–234. doi: 10.1016/j.jclinepi.2015.06.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Chen YL. Application of GRADE in system evaluation and practice guide. Lanzhou: Lanzhou University Press; 2017. [Google Scholar]
- 17.Balshem H, Helfand M, Schünemann HJ, et al. GRADE guidelines: 3. Rating the quality of evidence. J Clin Epidemiol. 2011;64(4):401–6. doi: 10.1016/j.jclinepi.2010.07.015. [DOI] [PubMed] [Google Scholar]
- 18.McKeon JF, Alvarez PM, Vajapey AS, et al. Expanding role of technology in rehabilitation after lower-extremity joint replacement: a systematic review. JBJS Rev. 2021 doi: 10.2106/JBJS.RVW.21.00016. [DOI] [PubMed] [Google Scholar]
- 19.McDonnell JM, Ahern DP, Ross TD, et al. The efficacy of remote virtual care in comparison to traditional clinical visits for elective orthopaedic patients: a meta-analysis of prospective randomised controlled trials. Surgeon. 2022;20(3):177–186. doi: 10.1016/j.surge.2021.02.008. [DOI] [PubMed] [Google Scholar]
- 20.Jansson MM, Rantala A, Miettunen J, et al. The effects and safety of telerehabilitation in patients with lower-limb joint replacement: a systematic review and narrative synthesis. J Telemed Telecare. 2022;28(2):96–114. doi: 10.1177/1357633X20917868. [DOI] [PubMed] [Google Scholar]
- 21.Liu J, Li LL, Gan YY, et al. Clinical effect of telerehabilitation after total knee arthroplasty: a meta-analysis. Chin J Rehabil Theory Pract. 2019;25(08):895–902. doi: 10.3969/j.issn.1006?9771.2019.00.006. [DOI] [Google Scholar]
- 22.Yoo JI, Oh MK, Lee SU, et al. Robot-assisted rehabilitation for total knee or hip replacement surgery patients: a systematic review and meta-analysis. Medicine. 2022;101(40):e30852. doi: 10.1097/MD.0000000000030852. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Wang X, Hunter DJ, Vesentini G, et al. Technology-assisted rehabilitation following total knee or hip replacement for people with osteoarthritis: a systematic review and meta-analysis. BMC Musculoskelet Disord. 2019;20(1):506. doi: 10.1186/s12891-019-2900-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Tsang MP, Man GCW, Xin H, et al. The effectiveness of telerehabilitation in patients after total knee replacement: a systematic review and meta-analysis of randomized controlled trials. J Telemed Telecare. 2022 doi: 10.1177/1357633X221097469. [DOI] [PubMed] [Google Scholar]
- 25.Shukla H, Nair SR, Thakker D. Role of telerehabilitation in patients following total knee arthroplasty: evidence from a systematic literature review and meta-analysis. J Telemed Telecare. 2017;23(2):339–346. doi: 10.1177/1357633X16628996. [DOI] [PubMed] [Google Scholar]
- 26.Jiang S, Xiang J, Gao X, et al. The comparison of telerehabilitation and face-to-face rehabilitation after total knee arthroplasty: a systematic review and meta-analysis. J Telemed Telecare. 2018;24(4):257–262. doi: 10.1177/1357633X16686748. [DOI] [PubMed] [Google Scholar]
- 27.Gazendam A, Zhu M, Chang Y, et al. Virtual reality rehabilitation following total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. Knee Surg Sports Traumatol Arthrosc. 2022;30(8):2548–2555. doi: 10.1007/s00167-022-06910-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Peng L, Zeng Y, Wu Y, et al. Virtual reality-based rehabilitation in patients following total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. Chin Med J. 2021;135(2):153–163. doi: 10.1097/CM9.0000000000001847. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Blasco J, Igual-Camacho C, Blasco M, et al. The efficacy of virtual reality tools for total knee replacement rehabilitation: a systematic review. Physiother Theory Pract. 2021;37(6):682–692. doi: 10.1080/09593985.2019.1641865. [DOI] [PubMed] [Google Scholar]
- 30.Wang Q, Lee RL, Hunter S, et al. The effectiveness of internet-based telerehabilitation among patients after total joint arthroplasty: a systematic review and meta-analysis of randomised controlled trials. J Telemed Telecare. 2023;29(4):247–260. doi: 10.1177/1357633X20980291. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
All data generated or analysed during this study are included in this article. Further enquiries can be directed to the corresponding author.