Abstract
Aerosolized viruses were passed through a high-intensity ultraviolet (UV) cell. This cell consisted of a long cylindrical aluminum tube [diameter, 7 in. (17.7 cm); length, 36 in. (91.4 cm)] with a highly reflective inner surface and a longitudinally extending helical baffle system which directed airborne particles in close proximity to a centrally located UV lamp. After having been passed through the UV cell, viral aerosols were collected with an Andersen sampler, and viral concentrations were determined by plaque assay methods on tissue cultures. Inactivation rates of greater than 99.9% were obtained for Coxsackie, influenza, Sindbis, and vaccinia viruses, and slightly less for adenovirus (96.8%), when the aerosols passed through the UV cell at 100 ft3/min. At aerosol flow rates of 200 ft3/min, inactivation rates were slightly lower; 91.3 for adenovirus, 97.5 and 96.7 for Coxsackie and Sindbis, respectively, and greater than 99.9% for influenza and vaccinia viruses.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- ANDERSEN A. A. New sampler for the collection, sizing, and enumeration of viable airborne particles. J Bacteriol. 1958 Nov;76(5):471–484. doi: 10.1128/jb.76.5.471-484.1958. [DOI] [PMC free article] [PubMed] [Google Scholar]
- HARPER G. J. Airborne micro-organisms: survival tests with four viruses. J Hyg (Lond) 1961 Dec;59:479–486. doi: 10.1017/s0022172400039176. [DOI] [PMC free article] [PubMed] [Google Scholar]
- HOLLAND J. J., McLAREN L. C. Improved method for staining cell monolayers for virus plaque counts. J Bacteriol. 1959 Oct;78:596–597. doi: 10.1128/jb.78.4.596-597.1959. [DOI] [PMC free article] [PubMed] [Google Scholar]
- SIMPSON R. W., HIRST G. K. Genetic recombination among influenza viruses. I. Cross reactivation of plaque-forming capacity as a method for selecting recombinants from the progeny of crosses between influenza A strains. Virology. 1961 Dec;15:436–451. doi: 10.1016/0042-6822(61)90111-8. [DOI] [PubMed] [Google Scholar]
- Wells W. F., Fair G. M. VIABILITY OF B. COLI EXPOSED TO ULTRA-VIOLET RADIATION IN AIR. Science. 1935 Sep 20;82(2125):280–281. doi: 10.1126/science.82.2125.280-a. [DOI] [PubMed] [Google Scholar]