Abstract
The Randolph Co. model 610 peristaltic, ⅛-hp pump was effective for preparative purposes in disrupting baker's yeast and spores of Bacillus globigii when suspended with glass beads. Best results were obtained with use of a slurry just fluid enough to flow through tubing while stirred. Beads of 0.2 and 0.1 mm were used to best advantage for the yeast cells and spores, respectively. Yeast cells were disrupted completely within 15 min, and the spores in 10 to 30 min. Temperature and surface denaturation are readily controlled, and the system is easily modified for use with large quantities of microorganisms.
Full text
PDF



Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- HAMILTON P. B., KNIGHT S. G. Ballistic disruption of Penicillium chrysogenum cells. Appl Microbiol. 1962 Nov;10:577–579. doi: 10.1128/am.10.6.577-579.1962. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LAMANNA C., CHATIGNY M. A., COLLEDGE E. H. Pumping as a means for the mechanical rupture of microorganisms mixed with glass beads. J Bacteriol. 1959 Jan;77(1):104–109. doi: 10.1128/jb.77.1.104-109.1959. [DOI] [PMC free article] [PubMed] [Google Scholar]